You are on page 1of 4

UBC DIVISION-III(Wind design)

S.No
1
2

Description
H = Height of the building
W = Width of the building

Units
m
m

50
40

considered for tulsyan

Condition:
Structure is sensitive to wind exited osillation
If H / W > 5 & Height > 121.9 m
3(a)

H/W

3(b)

Height of building

4(a)

Selected exposure type

4(b)

Ce =Combined height,exposure & gust factor coeff.

5(a)

Selected type of method

5(b)

Cq = Pressure coefficient

6(a)

Basic wind speed


qs = wind stagnation pressure

7(a)

C
1.8

(for 50 m height)

Method -2(Projected area) as we wont used gabled type structu


structure over 40 feet height

mph

1.4
0.7
0.5
1.2
70

psf
KN/m2

12.6
0.60354

Iw = Wind importance factor

Design wind pressure = Ce Cq qs Iw

note
1

1.25
No Wind oscillations
No Wind oscillations

1.25

KN/m2
Kg/cm2

(for vertical projected area)


(for horizontal projected area)
(top storey of partially enclosed structure)
(combined)
(from fig 16.1 based on the type of region)
(table = 16F)

(for essential or hazardous facility)(table 16

1.901151
0.0193797248

If H / W > 5 & Height > 121.9 m then the structure has to be designed by the appreoved
national standard
Terms related to wind design

considered for tulsyan

(table -16G)

we wont used gabled type structure &

al projected area)
ontal projected area)
y of partially enclosed structure)

16.1 based on the type of region)

ntial or hazardous facility)(table 16-K)