You are on page 1of 10

1

A
Seminar Report
On
HARMONIC REDUCTION AND POWER FACTOR IMPROVEMENT USING
ACTIVE FILTER WIND POWER GENRATING SYSTEM

Submitted in partial fulfillment


the requirements for the degree of

Bachelor of Engineering
in

Electrical (Electronics & Power) Engineering


of
Sant Gadge Baba Amravati University, Amravati

Submitted by

Mr. Ashish Rajendra Kulare


Under the guidance of

Prof.R.K.Mankar
Department of Electrical Engineering

Department of Electrical (Electronics & Power) Engineering


Shri Sant Gajanan Maharaj College of Engineering,
Shegaon,
Dist- Buldhana 444 203 (Maharashtra)
(2015-16)

Department of Electrical(Electronics & Power) Engineering

Shri Sant Gajanan Maharaj College of Engineering,


Shegaon 444203, Maharashtra, India

CERTIFICATE
The seminar report entitled Harmonic Reduction And Power Factor
Improvement using Using Shunt Active Filter In Wind Power
Genrating Sysstem is hereby approved as a creditable study carried
out and presented by Mr. Ashish Rajendra Kulare in a manner
satisfactory to warrant its acceptance as a pre-requisite in a partial
fulfillment of the requirements for degree of Bachelor of Engineering in
Electrical (Electronics & Power) Engineering of Sant Gadge Baba
Amravati University, Amravati.

Prof. R.K.Mankar
Guide

Dr.S.RParaskar
Head of the Dept, ELPO.

Acknowledgement
The real spirit of achieving a goal is through the way of excellence and
lustrous discipline. I would have never succeeded in completing my task without the
cooperation encouragement and help provided to me by various personalities.
I would like to take this opportunity to express my heartfelt thanks to my
guide Prof. R.K Mankar
for his esteemed guidance and encouragement, especially through difficult
times. His suggestions broaden my vision and guided me to succeed in this work. I am
also very grateful for his guidance and comments while studying part of my seminar
and learnt many things under his leadership.
I extend my thanks to Dr. S.R. Paraskar, Head of the dept. Electrical
(Electronics & Power) Engg. Department, Shri Sant Gajanan Maharaj College of
Engineering, Shegaon for their valuable support that made me a consistent performer.
I also extend my thanks to Dr. S. B. Somani, Principal, Shri Sant Gajanan
Maharaj College of Engineering, Shegaon for his valuable support.
Also I would like to thanks to all teaching and non-teaching staff of the
department for their encouragement, cooperation and help. My greatest thanks are to
all who wished me success especially my parents, my friends whose support and care
makes me stay on earth.

Place: SSGMCE, Shegaon

Ashish Rajendra Kulare

TABLE OF CONTENTS
1. Introduction
2. Filters
3. Types Of Filter
4. Shunt Active Filter
5. Configuration Of Wind Energy System
6. Principle Of Operation
7. Advantages & Drawbacks
8. Conclusion
9. Refernces

Introduction

Advantages
1 No Resonance Problem
2 Can Eliminates Any Harmonic (No Tuning)
3 Reliable Power Compensation
4 Reliable Operation
5 Improve Performance

Drawbacks
1 More Expensive
2 Complex Control System
3 Limit Bandwidth Of Active Device

Types Of Filter
1 Active Filter
2 Passive Filter
3 Unified Power Quality Controller

Principle Of Operation
In this operation 3 bus wind energy system is consider ,bus 1 and bus3have
Permenant magnet synchronous generator of 3 kw capacity .Genrator output changes
with respect different wind velocity and loading condition(when nonlinear load such
as adjustable speed drive ,battery charging system e.t.c), due variable frequency it
gives the flickering power hence oscillting generator output power is delivered to the
load at bus 2 . shunt active filter is connect in parallel across the line which employ
pulse width modulation based scheme & inject the reactive power in the system.
which helps to keep the constant frequency hence lower reactance which is required
to get constant power system and reduce the harmonic occurring along with the
improvement in the power factor.

Conclusion
conventional SAF with traditional PWM control is simple and
gives required output level but with less ripple in the output.
Using shunt active filter in WES through reduction in harmonics
inhance the power factor to standard level.

10