Professional Documents
Culture Documents
Fuses
Feature
benefit/description
Compact
Modular construction
18
Thomas & Betts Corporation 8155 T&B Boulevard Memphis TN 38125 800.888.0211 www.tnb.com
PG-PC-0506
15
25/28
35
10.0
17.2
23
95
125-140
150
34
40-45
50
53
78
103
11
19-21.5
26
200*
200*
200*
10*
10*
10*
15.5
23.0
FUSE RATINGS
Nominal Voltage Rating (kV)
8.3
10.0
17.2
23.0
Frequency (Hz)
50-60
50-60
50-60
3-80
3-50+
6-50+
50,000
50,000++
50,000
Fuses
Latching
Lever
200 Amp
Bushing Well
End Plug
with Eye
200 Amp
Bushing Well
EFX
Full-Range
Current-Limiting
Fuse
200 Amp
Bushing Well
Cable
Connection
Bushings
or Wells
600 Amp
Bushing
Molded EPDM
Rubber Insulation
and Shielding
200 Amp
Bushing Well
Mounting
Feet
Cable
Connection
Bushings
or Wells
600 Amp
Elbow
PG-PC-0506
Thomas & Betts Corporation 8155 T&B Boulevard Memphis TN 38125 800.888.0211 www.tnb.com
19
High Current
Interruption Element
Fuses
Epoxy
Joint
Compacted
Quartz Sand
Tin Plated
Brass Caps
Recommended EFX Mounted in a MCAN EPDM Rubber Insulated Dry Well Canister at 40 C Ambient Temperature
Recommended Fuse Current Ratings (Amperes)
Fuse Voltage
1-Phase Transformer
KVA
8.3kV
15.5kV
23kV
2.4
B
6
10
20
30
50
4.16
B
6a
6
10
8
18
12
25
18
40
25
30
A
4.8
B
3
6a
8
12
20
30
50
7.2
B
3a
3
6
8
10
12
12
20
18
25
30
A
7.62
B
3a
3
6
8
10
12
20
18
25
30
50
50
A
12
B
3a
3a
3
6a
6
10
12
25
50
10
15
25
12
37.5
20
50
12
25
75
20
50
100
25
167
18
250
25
333
50
500
NOTE: Column A = 140-200% of transformer rating and Column B = 200-300% of transformer rating
14.4
B
A
3a
3a
3
6a
6
8
12
10
25
18
40
25
30
12
20
25
50
16
B
3a
3a
3
6a
6a
8
10
20
30
50
19.9
A
B
6a
6a
6a
6a
6a
6
8
12
18
25
20
30
40
Recommended EFX Mounted in a MCAN EPDM Rubber Insulated Dry Well Canister at 40 C Ambient Temperature
Recommended Fuse Current Ratings (Amperes)
Fuse Voltage
3-Phase Transformer
KVA
15
22.5
30
45
75
100
112.5
150
200
225
300
500
750
1000
8.3kV
15.5kV
23kV
A
10
12
25
30
40
2.4
B
6
8
12
20
40
4.16
B
3
6a
6
10
20
12
25
18
30
20
50
25
40
50
A
12
18
18
25
30
40
4.8
B
3
6a
6
8
18
25
25
40
7.2-7.96
A
B
3a
3
6a
6
8
12
12
18
18
25
20
30
25
40
30
8.32
B
3a
3
3
6a
8
10
12
12
18
18
25
20
30
25
50
A
12.47
B
A
3a
3a
3a
3
6
8
8
10
12
18
12
20
18
25
30
13.2-14.4
B
A
3a
3a
3a
3
6
8
8
10
12
20
12
25
18
50
30
20.8
B
A
6a
6a
6a
6a
6a
6a
6a
6
8
10
12
25
18
50
25
40
22.9-24.9b
A
B
6a
6a
6a
6a
6a
6a
6a
6
8
8
12
18
25
25
40
40
NOTE: Column A = 140-200% of transformer rating and Column B = 200-300% of transformer rating
Recommended fuses meet inrush criteria of 12 times transformer full load current for 0.1 second and 25 times transformer full load current for
0.01 second. Fuses also meet cold load pickup criteria of 6 times transformer full load current for 1 second and 3 times transformer full load
current for 10 seconds. a. Fuse allows greater than 300% of transformer rating.
b. R
ecommendations limited to gndY-gndY transformers with no more than 50% delta connected secondary load.
Phase-to-ground rated fuses are frequently recommended for gndY-gndY three phase transformers.
20
Thomas & Betts Corporation 8155 T&B Boulevard Memphis TN 38125 800.888.0211 www.tnb.com
PG-PC-0506
3
6
8
10
12
18
20
25
30
40
50
65
80
3
6
8
10
12
18
20
25
30
40
50
6
8
10
12
18
20
25
30
40
50
4.3
9.5
11.5
13.5
17.5
19.5
24.0
29.5
34.0
40.0
45.5
70.0
80.0
4.3
9.5
11.5
13.5
17.5
19.5
24.0
29.5
34.0
40.0
44.5
9.5
11.5
13.5
17.5
19.5
24.0
29.5
34.0
38.5
44.5
8.3
15.5
23.0
EFX083003
EFX083006
EFX083008
EFX083010
EFX083012
EFX083018
EFX083020
EFX083025
EFX083030
EFX083040
EFX083050
EFX083065
EFX083080
EFX155003
EFX155006
EFX155008
EFX155010
EFX155012
EFX155018
EFX155020
EFX155025
EFX155030
EFX155040
EFX155050
EFX230006
EFX230008
EFX230010
EFX230012
EFX230018
EFX230020
EFX230025
EFX230030
EFX230040
EFX230050
10.0
8.8
17.2
23.0
4.2
9.0
11.0
13.0
17.0
19.0
23.0
28.5
33.0
39.0
44.0
68.0
77.5
4.2
9.0
11.0
13.0
17.0
19.0
23.0
28.5
33.0
39.0
43.0
9.0
11.0
13.0
17.0
19.0
23.0
28.5
33.0
37.0
43.0
3.9
8.5
10.5
12.5
16.0
18.0
21.5
27.0
31.0
36.5
42.0
64.5
73.5
3.9
8.5
10.5
12.5
16.0
18.0
21.5
27.0
31.0
36.5
40.0
8.5
10.5
12.5
16.0
18.0
21.5
27.0
31.0
35.0
40.0
Peak Arc
Minimum
2
Voltage
Melt l t
(kV)
2
(5)
(AMP -SEC)
30
32
28
28
26
26
26
26
26
26
26
23
22
51
54
46
46
43
45
45
45
45
45
45
67
61
61
60
60
60
60
60
60
60
100
620
800
800
920
1,310
1,620
3,660
5,250
8,700
12,800
34,000
51,200
100
620
800
800
920
1,310
1,620
3,660
5,250
8,700
12,800
620
800
800
920
1,310
1,620
3,660
5,250
8,700
12,800
Maximum
2
Total l t
(3) (4)
2
(AMP -SEC)
350
2,700
4,000
4,000
8,000
9,500
11,000
22,000
30,000
50,000
70,000
200,000
280,000
510
2,600
3,700
3,700
6,500
8,000
10,000
22,000
30,000
50,000
70,000
3,100
4,800
4,800
8,300
11,200
13,000
28,000
38,000
61,000
82,000
Fuses
Nominal Fuse
Current
Fuse
Voltage
Rating
Catalog
Rating
Number
(kV)
(A)
NOTES:
1. Designs have a 50,000 Amps rms. Symmetrical Rating (except 3A 17.2 kV which was tested at 44 kA maximum).
2. Tabulated Maximum Total I2t values are for currents of 50,000 amperes at the nominal voltage of the fuse. Fuses that have a Rated Maximum Voltage higher
than their Nominal Voltage Rating will have a higher I2t let-through when applied at voltages up to these higher values. For example, Maximum Total I2t values
are increased by approximately 30% when 8.3 kV fuses are applied at 10 kV and approximately 25% when 15.5 kV fuses are used at 17.2 kV.
3. Maximum total I2t values are reduced for currents below 50,000 A. For example, at 10,000 A, maximum total I2t values are approximately 15% less than the
published values.
4. Peak arc voltages quoted are for 50,000 A currents at the rated maximum voltage listed. Reduced currents and voltages will reduce the peak arc voltage.
Consult the factory for further information.
5. Maximum continuous currents at higher ambient temperatures may be determined by derating the fuses by 0.2% per degree C over 25O C. For example:
At 65O C the derating would be 40 x .2 = 8%, making the maximum continuous current of a 30 A fuse 41 x .92 = 38 A (in air) or 34 x .92 = 31 (in MCAN).
6. Reduction in the long time melting current of the fuses (approximately one hour and longer) due to higher ambient temperatures is the same as described above
Maximum continuous currents. See time-current characteristics for melting characteristics in this time region.
PG-PC-0506
Thomas & Betts Corporation 8155 T&B Boulevard Memphis TN 38125 800.888.0211 www.tnb.com
21
Fuses
Maximum Fuse
Overall Length
Diameter
Code
Maximum Fuse
Overall Diameter
10
2.25
14.31
2.25
17.12
2.25
ote: Lower Mounting Codes (shorter) fuses may be applied in canisters of higher Mounting Codes by
N
using an adapter. See Mounting Code Adapters table 7.
B
D
C
22
Thomas & Betts Corporation 8155 T&B Boulevard Memphis TN 38125 800.888.0211 www.tnb.com
PG-PC-0506
8.3
Fuse
Catalog
Number
EFX083003
EFX083006
EFX083008
EFX083010
EFX083012
EFX083018
EFX083020
EFX083025
EFX083030
EFX083040
EFX083050
65
EFX083065
80
EFX083080
3
6
8
10
12
18
20
25
30
40
50
6
8
10
12
18
20
25
30
40
50
15.5
23.0
EFX155003
EFX155006
EFX155008
EFX155010
EFX155012
EFX155018
EFX155020
EFX155025
EFX155030
EFX155040
EFX155050
EFX230006
EFX230008
EFX230010
EFX230012
EFX230018
EFX230020
EFX230025
EFX230030
EFX230040
EFX230050
Rated
Maximum
Voltage
(kV)
10.0
2.25
10.0
1.02
8.8
2.25
14.31
1.02
7.96
Canister
Catalog
Number
Fuse
Weight
(lbs)
MCAN-4B15-22
MCAN-4B15-66
MCAN-4B15-6E2
MCAN-4B15-6E6
3.00
Fuses
3
6
8
10
12
18
20
25
30
40
50
Nominal Fuse
Voltage Rating
(kV)
17.2
23.0
4.3
9.5
11.5
13.5
17.5
5
19.5
24.0
29.5
34.0
40.0
45.5
70.0
80.0
4.3
9.5
11.5
13.5
6
17.5
19.5
24.0
29.5
34.0
3.9
30
8.5
32
10.5
28
12.5
28
16.0
26
2.25 14.31 1.02
18.0
26
21.5
26
27.0
26
31.0
26
36.5
26
42.0
26
64.5
23
22
73.5
51
3.9
54
8.5
46
10.5
12.5
46
2.25 17.12 1.02
16.0
43
18.0
45
21.5
45
27.0
45
31.0
45
MCAN-5B15-22
MCAN-5B15-22
MCAN-5B15-66 4.25
12.27 MCAN-5B15-66
MCAN-5B15-6E2
MCAN-5B15-6E2
MCAN-5B15-6E6
100
350
620
2,700
800
4,000
800
MCAN-5B25-224,000
920
MCAN-5B25-668,000
12.27
4.25
MCAN-5B25-6E2
1,310
9,500
MCAN-5B25-6E6
1,620
11,000
3,660
22,000
5,250
30,000
8,700
50,000
12,800
70,000
34,000
200,000
51,200
280,000
100
510
620
2,600
800
3,700
800
3,700
15.09 MCAN-6B25-66
4.75
920
6,500
1,310
8,000
1,620
10,000
3,660
22,000
5,250
30,000
PG-PC-0506
Thomas & Betts Corporation 8155 T&B Boulevard Memphis TN 38125 800.888.0211 www.tnb.com
23
Approx.
Weight
(lbs)
End
Bushing*
Main
Bushing*
10.06 10.91
14.37 15.22
19
21
200 Amp
Bushing
Well
200 Amp
Bushing
Well
10.06 10.91
14.37 15.22
17.25 18.10
21
23
24
600 Amp
Bushing
600 Amp
Bushing
MCAN-4B15-6E2
MCAN-5B25-6E2
20
22
600 Amp
Elbow
Connector
200 Amp
Bushing
Well
MCAN-4B15-6E6
MCAN-5B25-6E6
20
22
600 Amp
Elbow
Connector
600 Amp
Bushing
Catalog Number
(A)
(B)
MCAN-4B15-22
MCAN-5B25-22
21.49
25.80
MCAN-4B15-66
MCAN-5B25-66
MCAN-6B25-66
21.49
25.80
28.68
(C)
Fuses
24
Thomas & Betts Corporation 8155 T&B Boulevard Memphis TN 38125 800.888.0211 www.tnb.com
PG-PC-0506