Professional Documents
Culture Documents
Cabling Solutions
from page 64
from page 74
from page 80
from page 84
from page 90
from page 96
from page 98
Safety cables
from page 46
from page 54
94
95
Fixing devices
100
101
102
103
109
110
Fixing devices
Support systems
Distribution boxes
Cable joints E30/E90
Distribution boxes
Connection/terminal boxes
106
107
108
Accessories
E0 multi-cable supports
Fire protection plugs / accessories
Fire protection screws
111
from page 112
114
Armoured conduits
Distribution boxes
Firestop systems
104
105
121
122
123
Information
Information
Colour codes in accordance
with VDE, CENELEC and SEV standards
E30-E90 support systems
Compendium of standards
Datwyler
A reliable partner at your side
Hotels, hospitals
Office blocks
Shopping centres
Data centres
Tunnels
Datwyler
Choose Datwyler!
Datwyler is a highly regarded company about to celebrate its 100th year of
operation. With the backing of a financially powerful group, Datwyler operates on the international stage as a successful supplier of total solutions for
the electrical and communications infrastructure of buildings and for FTTx
networks. We lead the way in innovations for applications such as information
and communications technology, power supply and safety, building automation and lifts.
Event arenas
Our systems are reliable and constitute a secure investment on your part. This
is all thanks to the years of experience and proven expertise of our engineers
and technicians. Datwyler is a one-stop source of customised solutions for all
your specific applications as attractive total solutions, with all the necessary
test certificates, authorisations and approvals and with long-term warranties.
Our workforce prides itself on delivering a full package of services for all the products and solutions supplied by the company. You can rely on our expert support
for all aspects of our supply beginning with planning, consultancy, through
pre-assembly, logistics, installation and ending with system maintenance.
FTTx projects
Datwyler
Datwyler
Worldwide expertise in turnkey creation, multi-site projects and services
Turnkey installations
Sa
f
rg
Imp
ut
En
om
atio
Electrical and
communications
infrastructure
Planning
Com
mu
on
ati
c
i
n
y
et
tenance
Main
Build
a
i ng
l e me n tat i o n
Datwyler
Datwyler
Datwyler
Datwyler
Added value
for fire-safety systems
Leading know-how
As a provider of total solutions for safety cable systems, Datwyler possesses comprehensive know-how accumulated over decades:
- Co-development of extended functional integrity tests in collaboration with renowned
testing institutes in the early 1990s.
- Sound knowledge of safety engineering and building codes and standards.
- Leading material, production and process know-how in the fabrication of safety cables
incorporating patented and proven ceramic technology.
- Development of the first metal-free fibre-optic cable with E30 extended functional
integrity through combining existing technical competence in data and safety cable
engineering.
- Broad systems competence.
- Collaboration with renowned technical universities, international standard committees
and independent testing institutes.
Diverse applications
Datwyler safety cable systems with extended functional integrity are used wherever stringent fire-safety requirements must be met and people and property could be at risk due
to fire and smoke:
- Airports, train stations, metro stations
- Hotels and hospitals
- Sports stadiums, theatres and concert halls
- Office and exhibition buildings, public buildings
- Tunnels for road and rail
Datwyler
System solutions
- The pyrofil cable line includes halogen-free, low-smoke
emission and flame resistant safety cables with circuit integrity and functional integrity.
- The Safety product line includes support systems, mounting
components and appropriate accessories to ensure functional integrity.
- Our FO Safety cables are the first metal-free fibre-optic cables
with E30 extended functional integrity with reference to DIN
4102-12.
- Fire protection seminars and special calculation programmes
offer engineers and installers valuable support
- Comprehensive services up to and including turnkey and
multi-site projects
Stuttgart
Berlin
Munich
Prague
Gotthard
Stuttgart
Datwyler
Proven quality
Steel conduits
and halogen-free
plastic conduits
Datwyler is the first European manufacturer to develop a complete system solution that meets the demands of todays industry for reliable power supply and data transmission in the event
of fire. pyrofil cables and our approved cabling system components are the result of many years of intensive development in
coordination with the relevant standardisation bodies.
Screws F90
Selected raw materials and special compounds in combination with unique installation methods are what give a Datwyler
system its high quality and maximum guaranty of safety in the
event of fire.
pyrofil cables and Datwyler safety system components are used
wherever people, machinery and equipment are endangered
by fire and smoke emission: in buildings with high density of
occupants as well as in facilities containing large concentrations
of valuable property.
Single clamps
type SAS
Spacing 600mm
page 100
Strap clamps
without trough type B
Spacing 800mm
page 101
Strap clamps
with trough type B
Spacing 800mm
page 102
Identification signs
page 104
10
Datwyler
from page 74
from page 74
WUM
Support measure
from page 95
Modular
shaft lighting system
from page 64
Cable joints
E30 and E90 for all
dimensions
page 106
Elevator travelling
cables
Multi cable support
Hermanschelle E30/E90
Spacing 600/800mm
Connection/terminal box
E30-E90
page 82
Distribution box
E30-E90
type Hercules
page103
page 108
page 96
page 107
Datwyler
11
Identification signs
Steel conduits
and halogen-free
plastic conduits
page 104
Single clamps
type SAS V4A
Spacing 600mm
page 100
Screws F90
Distribution boxes
E30/E90
from page 108
12
Datwyler
Distribution box
E30-E90
type Hercules
page 107
Strap clamps
without trough type B
Spacing 800mm
page 101
Strap clamps
with trough
type B
Spacing 800mm
page 102
Emergency lighting
for escape routes
page 110
from page 64
Datwyler
13
Cable
Applications
Product range/Standards
BRANDMELDEKABEL
Standards/Approvals
IEC, EN, CENELEC, BS, DIN VDE, SEV, NBN,
VKF, VdS, GOST-R, Ukraine
Standards/Approvals
IEC, EN, CENELEC, DIN VDE, SEV, NBN,
GOST-R
Standards/Approvals
IEC, EN, CENELEC, DIN VDE
14
Datwyler
System compatible
installation components
System components
Application
Seminars
Datwyler is setting new standards.
pyrofil safety cables combined with Datwyler system components make up the perfect and cost effective safety solution.
Datwyler
15
Product features
16
Datwyler
Zero halogen,
non corrosive gases
Flame propagation
IEC 60332-1-2,
EN 60332-1-2,
VDE 0482-332-1-2
Flame spread
Smoke density
Circuit integrity
[FE/PH]
System Circuit
integrity
[E30-E90]
Standards
- IEC 60754-1 and IEC 60754-2
- EN 50267-2-1, EN 50267-2-2
- EN 50267-2-3
- VDE 0482-267 part 2-1, 2-2 and 2-3
Standards
- IEC 60332-1-2
- EN 60332-1-2
- VDE 0482-332-1-2
Standards
- IEC 61034-1 and IEC 61034-2
- EN 61034-1 and EN 61034-2
- VDE 0482-1034 part 1 and 2
Datwyler
17
Test of
Circuit integrity
(Fire and water)
- BS 6387 (cat.W) [650C, 3A]
- VdS 3423 [>830C, 3A]
- EN 50200 Annex E [>830C, 2A]
18
Datwyler
Statement Datwyler
As an environmentally conscious manufacturer and supplier of cabling solutions it is
our concern not to use any environmentally
harmful substances in our products.
Based on current information, the hereinmentioned guidelines / regulations for
banned substances are fully complied with.
Exceptions are noted as such on the relevant
data sheet.
ROHS
REACH
DIRECTIVE 2002/95/EC
OF THE EUROPEAN PARLIAMENT
AND OF THE COUNCIL
of 27 January 2003 on the restriction of the use of certain hazardous substances in electrical and electronic
equipment
and
COMMISSION DECISION
of 24 September 2010 amending, for the purposes
of adapting to scientific and technical progress, the
Annex to Directive 2002/95/EC of the European Parliament and Council as regards exemptions for applications containing lead, mercury, cadmium, hexavalent
chromium, polybrominated biphenyls or polybrominated diphenyl ethers (2010/571/EU)
and
COMMISSION REGULATION (EU) No 143/2011
of 17 February 2011 amending Annex XIV to Regulation (EC) No 1907/2006 of the European Parliament and
of the council on the Registration, Evaluation, Authorisation and Restriction of Chemicals
WEEE
DIRECTIVE 2002/96/EC
OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL
of 27 January 2003 on waste electrical and electronic
equipment
Datwyler
19
H07Z-U/R
22 E0
H05Z-/H07Z-K
24 E0
NHXMH
26 E0
(N)HXM(St)H
28 E0
N2XH
30 E0
N2XCH
34 E0
FE5
36 FE5
FE5-CL
40 FE5
J-H(St)H...Bd, grey
42 E0
J-H(St)H...Bd, red
44 E0
20
46 FE180 UK
48 FE180 UK
50 FE180 UK
52 FE180 UK
54 FE180
58 FE180
60 FE180
Datwyler
Armoured
Ov. shield
Concentric
max. 90C
max. 70C
0.6/1 kV
450/750 V
300/500 V
max. 300 V
General properties
max. 225 V
BS
Rated voltage
SEV
EN/CLC/IEC
DIN VDE
Design
Circuit integrity
Fire resistant
Page Cat.
Flame retardant
Cable type
Halogen-free
Fire characteristics
Armoured
Ov. shield
Concentric
max. 90C
max. 70C
0.6/1 kV
General properties
450/750 V
300/500 V
max. 300 V
max. 225 V
BS
Rated voltage
SEV
EN/CLC/IEC
DIN VDE
Design
Circuit integrity
Fire resistant
Page Cat.
Flame retardant
Cable type
Halogen-free
Fire characteristics
64 E30-E60
68 E30-E60
70 E30-E60
74 E90
78 E90
80 E30
82 E30-E90
84 E30
86 E30-E90
88 E30-E90
90 (E30)
92 (E30)
Datwyler
21
H07Z-U/R
Conductor
Solid/stranded
Insulation
FRNC/LS0H
Application
Wiring for switches, distributors, devices and lighting in buildings. Suitable for laying in conduits
on or behind plasterwork and in closed installation ducts. Permitted operating temperature at
conductor of 90C, in accordance with HD 516.
Construction
Conductor
Insulation
Core colours
Technical Properties
Rated voltage
Test voltage
450/750V
0.6/1kV for fixed installation
2500V, 50Hz
General Properties
Operating temperature
permanent installation
during installation
Fixing devices
Support systems
Safety cables
Product information
22
Information
Accessories
Distribution boxes
Firestop systems
Zero halogen
non corrosive gases
Flame propagation
Smoke density
-40C to +90C
+5C to +50C
H07Z-U/R
Safety cables
Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240
RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
kg/km
app. kg/km
15
24
38
58
96
154
240
336
480
672
912
1152
1440
1776
2304
20
32
47
67
110
167
260
351
478
684
931
1150
1480
1800
2390
app. mm
2,8
3,4
3,9
4,4
5,6
7,0
8,5
9,6
11,1
12,9
15,1
16,2
18,2
20,2
23,2
app. kWh/m
0,05
0,06
0,07
0,08
0,09
0,14
0,18
0,21
0,27
0,32
0,43
0,47
0,59
0,73
0,92
Support systems
RE = circular, solid conductor
RM = circular, stranded conductor
n x mm2
Fixing devices
Information
Accessories
Distribution boxes
Firestop systems
Please specify required core colour when ordering. Additional dimensions available on request.
23
H05Z-K / H07Z-K
Insulation
FRNC/LS0H
Conductor
Flexible
Application
Wiring for switches, distributors, devices and lighting in buildings. Suitable for laying in conduits
on or behind plasterwork and in closed installation ducts. Permitted operating temperature at
conductor of 90C, in accordance with HD 516.
Construction
Conductor
Insulation
Core colours
Support systems
Technical Properties
Rated voltage
Test voltage
Fixing devices
Safety cables
Product information
General Properties
Operating temperature
permanent installation
during installation
24
Information
Accessories
Distribution boxes
Firestop systems
Zero halogen
non corrosive gases
Flame propagation
Smoke density
-40C to +90C
+5C to +50C
H05Z-K / H07Z-K
Safety cables
Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
n x mm2
1
1
1
1
1
1
1
1
1
1
1
1
x
x
x
x
x
x
x
x
x
x
x
x
0,75
1,0
1,5
2,5
4
6
10
16
25
35
50
70
kg/km
8
10
15
24
38
58
96
154
240
336
480
672
app. kg/km
11
14
19
32
51
73
115
177
273
371
530
736
app. mm
2,4
2,5
2,9
3,6
4,4
5,2
6,7
8,0
9,9
11,2
13,2
15,3
app. kWh/m
0,03
0,03
0,05
0,06
0,07
0,09
0,11
0,14
0,20
0,24
0,32
0,38
Support systems
Information
Accessories
Distribution boxes
Firestop systems
Fixing devices
Please specify required core colour when ordering. Additional dimensions available on request.
25
300/500V NHXMH
Power cable
Halogen-free, with improved fire characteristics
VDE 250-214
Insulation
Cross-linked PE
zero halogen
Sheath
FRNC/LS0H
Conductor
Solid/stranded
Application
For permanent installation in dry, damp or wet areas, on or behind plasterwork or in walls
or concrete, except for direct embedding in cast, rammed or vibrated concrete.
Also suitable for outdoor applications.
Permitted operating temperature at conductor of +70C.
Construction
Conductor
Insulation
Filler
Outer sheath
Core colours
Sheath colour
Imprint
Technical Properties
Nominal voltage
Test voltage
300/500V
2000V, 50Hz
General Properties
permanent installation
during installation
permanent installation
during installation
Distribution boxes
Firestop systems
Fixing devices
Support systems
Safety cables
Product information
Accessories
Information
26
Filler
Flame retardant,
zero halogen
4 x D (D = outer diameter)
6xD
-40C to +70C
+5C to +50C
300/500V NHXMH
Power cable
Halogen-free, with improved fire characteristics
VDE 250-214
Safety cables
Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
app. kWh/m
RE
RE
29
48
100
115
8,5
9,0
0,33
0,40
149 254
154 369
154 677
154 678
173 842
3
3
3
3
3
x 1,5
x 2,5
x
4
x
6
x 10
RE
RE
RE
RE
RE
43
72
115
173
288
110
145
230
300
510
9,0
9,5
12,0
13,0
16,0
0,33
0,38
0,59
0,68
1,08
154 367
154 679
154 680
154 681
174 718
4
4
4
4
4
x 1,5
x 2,5
x
4
x
6
x 10
RE
RE
RE
RE
RE
58
96
154
230
384
130
200
290
390
620
9,5
10,5
12,5
14,0
17,0
0,38
0,46
0,70
0,83
1,25
154 368
154 370
154 371
154 372
169 929
169 930
5
5
5
5
5
5
x 1,5
x 2,5
x
4
x
6
x 10
x 16
RE
RE
RE
RE
RE
RM
72
120
192
288
480
768
150
205
340
455
730
1150
10,0
11,0
13,5
15,0
18,5
22,5
0,44
0,50
0,81
0,93
1,44
2,06
154 682
154 683
7
7
x 1,5
x 2,5
RE
RE
101
168
195
285
10,5
12,5
0,55
0,74
174 719
10
x 1,5
RE
144
330
14,5
0,92
156 849
12
x 1,5
RE
173
345
15,0
0,95
174 720
RE = circular, solid conductor
RM = circular, stranded conductor
24
x 1,5
RE
346
610
19,5
1,65
Information
Support systems
app. mm
x 1,5
x 2,5
Fixing devices
app. kg/km
2
2
Firestop systems
kg/km
154 675
154 676
Distribution boxes
n x mm2
Accessories
27
(N)HXM(St)H
Sheath
FRNC/LS0H
Drain wire
Tinned
copper
Conductor
Solid/stranded
Application
Construction
Conductor
Insulation
Filler
Shielding
Outer sheath
Core colours
Sheath colour
Imprint
Technical Properties
Nominal voltage
Test voltage
300/500V
2000V, 50Hz
General Properties
permanent installation
during installation
permanent installation
during installation
Distribution boxes
Firestop systems
Fixing devices
Support systems
Safety cables
Product information
Accessories
Information
28
Shielding
Al-laminated
tape
Insulation
Cross-linked PE
zero halogen
4 x D (D = outer diameter)
6xD
-40C to +70C
+5C to +50C
(N)HXM(St)H
Safety cables
Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
n x mm2
kg/km
app. kg/km
app. mm
app. kWh/m
2
2
x 1,5
x 2,5
RE
RE
43
63
119
151
8,5
9,7
0,26
0,32
1301 193
1301 194
3
3
x 1,5
x 2,5
RE
RE
58
87
137
180
9,0
10,0
0,36
0,42
1301 212
1301 213
4
4
x 1,5
x 2,5
RE
RE
72
111
160
213
10,0
11,0
0,41
0,48
1301 214
1301 195
RE = circular, solid conductor
RM = circular, stranded conductor
5
5
x 1,5
x 2,5
RE
RE
87
135
187
253
11,0
12,0
0,48
0,56
Support systems
Information
Accessories
Distribution boxes
Firestop systems
Fixing devices
29
N2XH
Sheath
FRNC/LS0H
Conductor
Solid/stranded
Application
For permanent installation in dry, damp or wet areas, on or behind plasterwork or in walls or concrete.
Also suitable for outdoor applications. The cable should only be laid directly in earth or water if a
protective conduit is used. Permitted operating temperature at conductor of +90C.
Construction
Conductor
Insulation
Filler
Outer sheath
Core colours
Sheath colour
Imprint
Electrical Properties
Nominal voltage
Test voltage
0.6/1kV
4000V, 50Hz
General Properties
Distribution boxes
Firestop systems
Fixing devices
Support systems
Safety cables
Product information
Accessories
Information
30
Filler
Flame retardant,
zero halogen
N2XH
No. of cores x cross section Core colours Cu content Total weight Outer diameter Fire load
4
4
6
6
10
10
16
16
25
25
35
35
50
50
70
70
95
95
120
120
150
150
185
185
240
240
300
300
RE
RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
black
green/yellow
black
green/yellow
black
green/yellow
black
green/yellow
black
green/yellow
black
green/yellow
black
green/yellow
black
green/yellow
black
green/yellow
black
green/yellow
black
green/yellow
black
green/yellow
black
green/yellow
black
green/yellow
kg/km
app. kg/km
38
38
58
58
96
96
154
154
240
240
336
336
480
480
672
672
912
912
1152
1152
1440
1440
1776
1776
2304
2304
2880
2880
75
75
97
97
140
140
202
202
302
302
397
397
523
523
745
745
986
986
1214
1214
1536
1536
1888
1888
2472
2472
2945
2945
app. mm
6,4
6,4
6,9
6,9
7,7
7,7
9,1
9,1
11,0
11,0
12,0
12,0
13,0
13,0
15,0
15,0
17,0
17,0
18,0
18,0
21,0
21,0
23,0
23,0
26,0
26,0
28,0
28,0
app. kWh/m
0,20
0,20
0,22
0,22
0,26
0,26
0,36
0,36
0,48
0,48
0,55
0,55
0,65
0,65
0,84
0,84
0,97
0,97
1,10
1,10
1,43
1,43
1,72
1,72
2,02
2,02
2,34
2,34
Support systems
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Information
Accessories
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Fixing devices
170 000
170 022
170 001
170 002
170 015
170 023
170 003
170 014
170 004
170 005
170 010
170 026
170 006
170 007
170 018
170 030
170 008
170 009
170 019
170 025
170 020
191 566
170 011
170 031
170 012
170 016
170 013
170 029
RE = circular, solid conductor
RM = circular, stranded conductor
n x mm2
Firestop systems
Distribution boxes
Article No.
Safety cables
Product information
31
N2XH
Safety cables
Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
kg/km
app. kg/km
app. mm
app. kWh/m
x 1,5
RE
29
120
8,0
0,38
188 201
188 204
188 349
188 210
190 505
188 216
3
3
3
3
3
3
x 1,5
x 2,5
x
4
x
6
x 10
x 16
RE
RE
RE
RE
RE
RM
43
72
115
173
288
461
135
181
242
319
464
697
9,0
10,0
11,0
12,5
14,0
17,0
0,44
0,51
0,60
0,70
0,83
1,22
188 202
188 205
188 208
188 211
188 214
188 217
188 219
188 028
188 222
188 030
188 224
RE = circular, solid conductor
RM = circular, stranded conductor
4
4
4
4
4
4
4
4
4
4
4
x 1,5
x 2,5
x
4
x
6
x 10
x 16
x 25
x 35
x 50
x 70
x 95
RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM
58
96
154
230
384
614
960
1344
1920
2688
3648
163
214
294
390
586
874
1332
1777
2343
3384
4490
10,0
11,0
12,0
14,0
16,0
19,0
23,0
26,0
29,0
35,0
39,0
0,52
0,60
0,72
0,83
1,03
1,50
2,14
2,57
3,15
4,17
5,16
Accessories
Information
32
n x mm2
190 524
Distribution boxes
Firestop systems
Fixing devices
Support systems
N2XH
Safety cables
Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
x 1,5
x 2,5
x
4
x
6
x 10
x 16
x 25
RE
RE
RE
RE
RE
RM
RM
72
120
192
288
480
768
1200
193
256
352
475
708
1081
1631
11,0
12,0
13,0
15,0
17,0
21,0
25,5
0,62
0,71
0,85
0,99
1,22
1,87
3,32
170 095
170 096
7
7
x 1,5
x 2,5
RE
RE
101
168
230
315
12,0
13,0
0,73
0,85
170 104
170 105
10
10
x 1,5
x 2,5
RE
RE
144
240
326
447
15,0
16,0
1,03
1,20
170 099
170 106
12
12
x 1,5
x 2,5
RE
RE
173
288
365
510
15,0
17,0
1,14
1,33
170 107
14
x 1,5
RE
202
420
16,0
1,27
170 100
19
x 1,5
RE
274
511
18,0
1,58
170 101
24
x 1,5
RE
346
664
21,0
2,06
170 108
RE = circular, solid conductor
RM = circular, stranded conductor
30
x 1,5
RE
432
793
22,0
2,41
app. kWh/m
Information
Accessories
app. mm
Support systems
app. kg/km
5
5
5
5
5
5
5
Fixing devices
kg/km
188 203
188 206
188 357
188 358
188 215
188 218
188 220
Firestop systems
n x mm2
Distribution boxes
33
N2XCH
Sheath
FRNC/LS0H
Concentric conductor
Bare copper
wire
Insulation
Cross-linked PE
zero halogen
Filler
Flame retardant,
zero halogen
Application
Construction
Conductor
Insulation
Filler
Concentric conductor
Separator
Outer sheath
Core colours
Sheath colour
Imprint
Electrical Properties
Nominal voltage
Test voltage
0.6/1kV
4000V, 50Hz
General Properties
Distribution boxes
Firestop systems
Fixing devices
Support systems
Safety cables
Product information
Accessories
Information
34
Reinforcing helix
Bare copper
tape
Conductor
Solid/
stranded
N2XCH
Safety cables
Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
162
206
11,0
12,0
0,43
0,49
188 226
188 229
188 231
188 233
188 235
188 237
188 239
188 241
188 243
3
3
3
3
3
3
3
3
3
x 1,5 RE/1,5
x 2,5 RE/2,5
x
4 RE/4
x
6 RE/6
x 10 RE/10
x 16 RM/16
x 25 RM/16
x 35 RM/16
x 50 RM/25
66
104
161
240
408
643
902
1190
1723
180
234
319
430
611
924
1280
1634
2235
11,0
12,0
14,0
15,0
17,0
20,0
23,0
26,0
29,0
0,48
0,55
0,65
0,75
0,94
1,47
1,94
2,29
2,72
188 227
188 230
188 232
188 234
188 236
188 238
188 240
188 242
188 244
188 245
188 246
188 247
188 248
188 249
188 250
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
81
128
200
297
504
796
1142
1526
2203
3082
4208
5388
6540
8159
10546
205
269
375
510
745
1107
1572
2013
2759
3899
5164
6494
7959
9932
12989
12,0
13,0
15,0
16,0
18,0
21,0
25,0
28,0
32,0
38,0
42,0
46,0
52,0
57,0
65,0
0,56
0,64
0,79
0,92
1,10
1,75
2,36
2,75
3,38
4,48
5,44
6,38
7,97
9,86
12,01
170 156
170 191
170 192
170 193
7
7
7
7
x 1,5 RE/2,5
x 2,5 RE/2,5
x
4 RE/4
x
6 RE/6
133
200
315
470
286
373
532
727
14,0
15,0
17,0
18,0
0,78
0,89
1,11
1,25
170 157
170 195
12
12
x 1,5 RE/2,5
x 2,5 RE/4
205
334
429
600
17,0
19,0
1,18
1,40
170 158
24
x 1,5 RE/6
413
790
23,0
2,14
170 159
30
x 1,5 RE/6
499
921
25,0
2,52
840
1319
28,0
3,01
1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240
RE/1,5
RE/2,5
RE/4
RE/6
RE/10
RM/16
RM/16
RM/16
RM/25
RM/35
RM/50
RM/70
RM/70
RM/95
RM/120
170 196
30
x 2,5 RE/10
RE = circular, solid conductor, RM = circular, stranded conductor
Additional dimensions available on request.
Support systems
app. kWh/m
52
80
Fixing devices
app. mm
x 1,5 RE/1,5
x 2,5 RE/2,5
Firestop systems
app. kg/km
2
2
Distribution boxes
kg/km
188 225
188 228
Accessories
n x mm2
Information
35
FE5
Insulation
Polyolefin
flame retardant, low smoke,
zero halogen
Conductor
Solid/stranded
Sheath
FRNC/LS0H
Application
For permanent installation in dry, damp or wet areas, on or behind plasterwork or in walls or
concrete. The cable should only be laid directly in earth or water if a protective conduit is used.
Permitted operating temperature at conductor of +90C.
Construction
Conductor
Insulation
Outer sheath
Core colours
Sheath colour
Imprint
Electrical Properties
Nominal voltage
Test voltage
0.6/1kV
3500V, 50Hz
General Properties
Distribution boxes
Firestop systems
Fixing devices
Support systems
Safety cables
Product information
36
Information
Accessories
Zero halogen
non corrosive gases
Flame propagation
Flame spread
Smoke density
FE5
Safety cables
Product information
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
16
16
25
25
35
35
50
50
70
70
95
95
120
120
150
150
185
185
240
240
300
300
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
black
green/yellow
black
green/yellow
black
green/yellow
black
green/yellow
black
green/yellow
black
green/yellow
black
green/yellow
black
green/yellow
black
green/yellow
black
green/yellow
black
green/yellow
kg/km
app. kg/km
app. mm
kWh/m
154
154
240
240
336
336
480
480
672
672
912
912
1152
1152
1440
1440
1776
1776
2304
2304
2880
2880
202
202
302
302
397
397
523
523
745
745
986
986
1214
1214
1536
1536
1888
1888
2472
2472
2945
2945
9,1
9,1
11
11
12
12
13
13
15
15
17
17
18
18
21
21
23
23
26
26
28
28
0,36
0,36
0,48
0,48
0,55
0,55
0,65
0,65
0,84
0,84
0,97
0,97
1,1
1,1
1,43
1,43
1,72
1,72
2,02
2,02
2,34
2,34
Fixing devices
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Firestop systems
170 003
170 014
170 004
170 005
170 010
170 026
170 006
170 007
170 018
170 030
170 008
170 009
170 019
170 025
170 020
170 011
170 031
170 012
170 016
170 013
170 029
RE = circular, solid conductor
RM = circular, stranded conductor
n x mm2
Support systems
Article No. No. of cores x cross section Core colour Cu content Total weight Outer diameter Fire load
Information
Accessories
Distribution boxes
37
FE5
Safety cables
Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
Firestop systems
Fixing devices
Support systems
kg/km
app. kg/km
app. mm
kWh/m
2
2
x 1.5
x 2.5
RE
RE
29
48
73
109
8
9
0,17
0,24
188 216
3
3
3
3
3
3
x 1.5
x 2.5
x
4
x
6
x 10
x 16
RE
RE
RE
RE
RE
RM
43
72
115
173
288
461
88
130
189
282
435
697
8
9
11
12
15
17
0,18
0,24
0,31
0,45
0,63
1,22
188 217
188 219
188 028
188 222
188 030
188 224
RE = circular, solid conductor
RM = circular, stranded conductor
4
4
4
4
4
4
4
4
4
4
4
x 1.5
x 2.5
x
4
x
6
x 10
x 16
x 25
x 35
x 50
x 70
x 95
RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM
58
96
154
230
384
614
960
1344
1920
2688
3648
115
169
247
352
543
874
1332
1777
2343
3384
4490
9
10
12
13
16
19
23
26
29
35
39
0,23
0,29
0,39
0,51
0,68
1,5
2,14
2,57
3,15
4,17
5,16
Information
Accessories
Distribution boxes
38
n x mm2
FE5
Safety cables
Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
app. kg/km
5
5
5
5
5
5
5
x 1.5
x 2.5
x
4
x
6
x 10
x 16
x 25
RE
RE
RE
RE
RE
RM
RM
72
120
192
288
480
768
1200
144
212
310
433
690
1081
1631
app. mm
10,0
11,0
13,0
15,0
18,0
21,0
25,5
kWh/m
0,29
0,38
0,49
0,61
0,87
1,87
3,32
180 005
180 010
188 324
181 983
190 563
7
7
7
7
7
x 1.5
x 2.5
x
4
x
6
x 10
RE
RE
RE
RE
RE
101
168
269
403
672
185
275
410
572
902
10,0
12,0
14,0
16,0
20,0
0,34
0,45
0,59
0,73
1,03
8
8
x 1.5
x 2.5
RE
RE
115
192
211
317
11,0
13,0
0,38
0,50
180 961
10
10
x 1.5
x 2.5
RE
RE
144
240
267
402
13,0
16,0
0,50
0,67
181 020
RE = circular, solid conductor
RM = circular, stranded conductor
12
12
x 1.5
x 2.5
RE
RE
173
288
315
466
14,0
16,0
0,64
0,83
Support systems
kg/km
188 288
188 289
188 290
191 077
188 218
188 220
Fixing devices
n x mm2
Firestop systems
Information
Accessories
Distribution boxes
39
FE5-CL
Sheath
FRNC/LS0H
Inner sheath
Polyolefin
flame retardant,
zero halogen
Conductor
Solid/stranded
Application
For permanent installation in dry, damp or wet areas, on or behind plasterwork or in walls or
concrete. Also suitable for outdoor applications. The cable should only be laid directly in earth
or water if a protective conduit is used.
Permitted operating temperature at conductor of +90C.
Construction
Conductor
Insulation
Inner sheath
Armouring/
rodent protection
Outer sheath
Core colours
Sheath colour
Imprint
Electrical Properties
Nominal voltage
Test voltage
0.6/1kV
3500V, 50Hz
General Properties
Distribution boxes
Firestop systems
Fixing devices
Support systems
Safety cables
Product information
Accessories
Information
40
Insulation
Cross-linked PE
zero halogen
Armouring
Galvanised
steel tape
Single core cable with copper tape [CLCU) and Multicore cable
with galvanised steel tape [CL]
Flame retardant Polyolefin compound
CENELEC HD 604 S1 part 5 sec. H
CENELEC HD 308 S2
Black
On request
FE5-CL
Safety cables
Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
173
170
171
190
240
350
515
770
189
220
305
420
630
1000
1450
1950
270
375
510
760
820
1200
1750
2400
3200
4550
6050
230
330
460
651
980
272
389
329
470
367
530
850
1050
app. mm
10
10
10
11
12
14
16
20
10
11
13
15
17
22
26
30
12
14
16
19
21
24
28
33
37
44
50
11
13
15
17
21
13
15
14
17
15
17
22
24
kWh/m
0,30
0,40
0,33
0,43
0,53
0,72
0,96
1,55
0,38
0,50
0,62
0,80
1,08
1,92
2,53
3,26
0,61
0,77
0,96
1,31
1,53
2,17
2,85
3,94
4,90
6,60
8,64
0,54
0,71
0,91
1,15
1,58
0,62
0,82
0,77
1,01
0,94
1,26
2,00
2,16
Support systems
app. kg/km
29
48
43
72
115
173
288
461
58
96
154
230
384
614
960
1344
120
192
288
480
480
768
1200
1680
2400
3360
4560
101
168
269
403
672
115
192
144
240
173
288
504
389
Fixing devices
kg/km
Firestop systems
RE
RE
RE
RE
RE
RE
RE
RM
RE
RE
RE
RE
RE
RM
RM
RM
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM
RM
RE
RE
RE
RE
RE
RE
RE
RE
RE
RE
RE
RE
RE
Distribution boxes
2
x 1,5
2
x 2,5
3
x 1,5
191 007
3
x 2,5
191 091
3
x
4
191 645
3
x
6
191 568
3
x 10
3
x 16
191 672
4
x 1,5
4
x 2,5
4
x
4
4
x
6
4
x 10
4
x 16
4
x 25
4
x 35
191 064
5
x 2,5
5
x
4
190 595
5
x
6
188 389
5
x 10
5
x 10
190 401
5
x 16
191 063
5
x 25
191 090
5
x 35
191 036
5
x 50
5
x 70
191 600
5
x 95
7
x 1,5
180 930
7
x 2,5
7
x
4
180 929
7
x
6
184 531
7
x 10
8
x 1,5
8
x 2,5
10
x 1,5
10
x 2,5
12
x 1,5
192 240
12
x 2,5
21
x 2,5
27
x 2,5
RE = circular, solid conductor, RM = circular, stranded conductor
Additional dimensions available on request.
Accessories
n x mm2
Information
41
J-H(St)H...Bd
Sheath
FRNC/LS0H
Drain wire
Tinned
copper
Conductor
Solid
Application
Installation cable with electrostatic shield in fire vulnerable areas with high concentration
of people and property value. For telecommunication and IT systems for lossless data
and signal transmission. Suitable for fixed laying in dry and humid rooms, on-wall and
in-wall, outdoor use, no laying underground. Not to be used for power transmission.
Permitted operating temperature at conductor of +70C.
Construction
Conductor
Insulation
Core idendification
Stranding
Shielding
Outer Sheath
Sheath colour
Electrical Properties
Rated voltage
Test voltage
Conductor resistance
Loop:
Insulation resistance
Capacity
max. 300 V
800V 50Hz
Firestop systems
Fixing devices
Support systems
Safety cables
Product information
Distribution boxes
General Properties
Accessories
Information
42
Shielding
Al-laminated
plastic-foil
Insulation
Halogen-free
polymer compound
Zero halogen
non corrosive gases
Flame propagation
Flame spread
Smoke density
2,5 x D
7,5 x D
(D = outer diameter)
-30 C bis +70 C
- 5 C bis +50 C
J-H(St)H...Bd
Safety cables
Product information
Article No. No. of cores x conductor diameter Cu content Total weight Outer diameter Fire load
app. kg/km
app. mm
app. kWh/m
2
2
2
2
2
2
2
2
2
2
2
2
x
x
x
x
x
x
x
x
x
x
x
x
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
0,6
9
14
25
37
59
116
172
229
286
342
455
568
33
49
92
101
146
310
352
464
573
661
876
1056
5,0
6,0
9,0
9,0
11,0
16,0
17,0
19,0
21,0
23,0
27,0
29,0
0,90
0,12
0,18
0,23
0,33
0,72
0,81
1,05
1,34
1,50
2,01
2,53
1
2
4
6
10
20
30
40
50
60
80
100
x
x
x
x
x
x
x
x
x
x
x
x
2
2
2
2
2
2
2
2
2
2
2
2
x
x
x
x
x
x
x
x
x
x
x
x
0,8
0,8
0,8
0,8
0,8
0,8
0,8
0,8
0,8
0,8
0,8
0,8
15
25
45
65
106
206
307
407
508
608
809
1010
56
69
136
152
230
508
599
787
973
1121
1476
1805
6,0
7,0
11,0
11,0
13,0
21,0
22,0
25,0
25,0
30,0
34,0
38,0
0,12
0,16
0,29
0,35
0,55
1,21
1,36
1,67
2,19
2,44
3,18
4,07
191 001
152 838
152 689
152 839
152 840
152 841
1159 967
1172 012
1172 013
1172 014
1172 015
1172 016
Support systems
kg/km
x
x
x
x
x
x
x
x
x
x
x
x
Fixing devices
n x mm
1
2
4
6
10
20
30
40
50
60
80
100
Firestop systems
152 833
152 834
152 835
152 836
152 837
154 450
1154 451
154 452
154 453
154 454
154 455
Information
Accessories
Distribution boxes
43
J-H(St)H...Bd
Insulation
Halogen-free
polymer compound
BRANDMELDEKABEL
Sheath
FRNC/LS0H
Drain wire
Tinned
copper
Conductor
Solid
Application
Installation cable with electrostatic shield in fire vulnerable areas with high concentration
of people and property value. For telecommunication and IT-systems for lossless data
and signal transmission. Suitable for fixed laying in dry and humid rooms, on-wall and
in-wall, outdoor use, no laying underground. Not to be used for power transmission.
Permitted operating temperature at conductor of +70C.
Construction
Conductor
Insulation
Core idendification
Stranding
Shielding
Outer Sheath
Sheath colour
Electrical Properties
Rated voltage
Test voltage
Conductor resistance
Loop:
Insulation resistance
Capacity
max. 300 V
800V 50Hz
Firestop systems
Fixing devices
Support systems
Safety cables
Product information
Distribution boxes
General Properties
Accessories
Information
44
Shielding
Al-laminated
plastic-foil
Zero halogen
non corrosive gases
Flame propagation
Flame spread
Smoke density
2,5 x D
7,5 x D
(D = outer diameter)
-30 C bis +70 C
- 5 C bis +50 C
J-H(St)H...Bd
Safety cables
Product information
Article No. No. of cores x conductor diameter Cu content Total weight Outer diameter Fire load
n x mm
kg/km
app. kg/km
15
25
45
65
106
206
307
407
508
608
809
1010
56
69
136
152
230
508
599
787
973
1121
1476
1805
app. mm
6,0
7,0
11,0
11,0
13,0
21,0
22,0
25,0
25,0
30,0
34,0
38,0
app. kWh/m
0,12
0,16
0,29
0,35
0,55
1,21
1,36
1,67
2,19
2,44
3,18
4,07
Support systems
184 707
1 x 2 x
0,8
157 892
2 x 2 x
0,8
157 893
4 x 2 x
0,8
157 894
6 x 2 x
0,8
157 895
10 x 2 x
0,8
1172 017
20 x 2 x
0,8
1172 018
30 x 2 x
0,8
1172 019
40 x 2 x
0,8
157 406
50 x 2 x
0,8
1172 020
60 x 2 x
0,8
1172 021
80 x 2 x
0,8
1172 022
100 x 2 x
0,8
Fire alarm cable with red sheath and imprint Brandmeldekabel (fire alarm cable).
Information
Accessories
Distribution boxes
Firestop systems
Fixing devices
45
Sheath
FRNC/LS0H
Conductor
Solid
Cable for fire alarm systems and emergency lighting for permament installation in buildings.
Permitted operating temperature at conductor +90C.
Construction
Conductor
Insulation
Core colours
Inner covering
Shielding
Separator
Sheath
Sheath colour
Imprint
Electrical Properties
Nominal voltage
Test voltage
300/500V
2000V, 50Hz
General Properties
Zero halogen,
non corrosive gases
Flame propagation
Flame spread
Smoke density
Circuit integrity [FE/PH]
Safety cables
Firestop systems
Fixing devices
Support systems
Application
Distribution boxes
Accessories
Information
Drain wire
Tinned
copper
Product information
46
Shielding
Al-laminated
tape
Insulation
Fire resistant
special compound
Safety cables
Product information
Article No. Colour No. of cores x cross section Cu content Total weight Outer diameter Fire load
app. kg/km
app. mm
kWh/m
red
white
red
white
red
white
2
2
2
2
2
2
x
x
x
x
x
x
1,0
1,0
1,5
1,5
2,5
2,5
29
29
43
43
72
72
78
78
98
98
141
141
7,7
7,7
8,3
8,3
9,7
9,7
0,17
0,17
0,19
0,19
0,26
0,26
187 206
188 154
187 210
187 211
187 215
187 216
red
white
red
white
red
white
3
3
3
3
3
3
x
x
x
x
x
x
1,0
1,0
1,5
1,5
2,5
2,5
38
38
58
58
96
96
95
95
120
120
181
181
8,1
8,1
8,7
8,7
10,3
10,3
0,20
0,20
0,23
0,23
0,31
0,31
187 207
187 208
187 212
187 213
187 217
188 155
red
white
red
white
red
white
4
4
4
4
4
4
x
x
x
x
x
x
1,0
1,0
1,5
1,5
2,5
2,5
48
48
72
72
120
120
119
119
150
150
224
224
9,0
9,0
9,7
9,7
11,4
11,4
0,25
0,25
0,28
0,28
0,39
0,39
188 317
red
1,5
115
230
11,6
0,42
Information
Accessories
Distribution boxes
Support systems
kg/km
187 204
187 205
187 209
187 161
187 214
187 162
Fixing devices
n x mm2
Firestop systems
47
Sheath
FRNC/LS0H
Conductor
Stranded
Cable for fire alarm systems and emergency lighting for permament installation in buildings.
Permitted operating temperature at conductor +90C.
Construction
Conductor
Insulation
Core colours
Inner covering
Shielding
Separator
Sheath
Sheath colour
Imprint
Electrical Properties
Nominal voltage
Test voltage
300/500V
2000V, 50Hz
General Properties
Zero halogen,
non corrosive gases
Flame propagation
Flame spread
Smoke density
Circuit integrity [FE/PH]
Safety cables
Firestop systems
Fixing devices
Support systems
Application
Distribution boxes
Accessories
Information
Drain wire
Tinned
copper
Product information
48
Shielding
Al-laminated
tape
Insulation
Fire resistant
special compound
Safety cables
Product information
Article No. Colour No. of cores x cross section Cu content Total weight Outer diameter Fire load
n x mm2
kg/km
app. kg/km
app. mm
kWh/m
190 438
190 427
190 429
red
red
red
2 x
2 x
2 x
1,0
1,5
2,5
29
43
72
83
103
152
8,0
8,9
10,4
0,20
0,23
0,30
190 439
red
red
red
3 x
3 x
3 x
1,0
1,5
2,5
38
58
96
101
130
190
8,5
9,4
11,0
0,24
0,27
0,35
190 440
red
red
red
4 x
4 x
4 x
1,0
1,5
2,5
48
72
120
127
161
235
9,4
10,4
12,2
0,25
0,31
0,44
Information
Accessories
Distribution boxes
Firestop systems
Fixing devices
Support systems
49
Sheath
FRNC/LS0H
Drain wire
Tinned
copper
Conductor
Solid
Application
Cable for fire alarm systems and emergency lighting for permament installation in buildings.
Permitted operating temperature at conductor +90C.
Construction
Conductor
Insulation
Core colours
Inner covering
Shielding
Separator
Sheath
Sheath colour
Imprint
Electrical Properties
Nominal voltage
Test voltage
300/500V
2000V, 50Hz
General Properties
Firestop systems
Fixing devices
Support systems
Safety cables
Product information
Distribution boxes
Accessories
Information
50
Shielding
Alu-laminated
tape
Insulation
Fire resistant
special compound
Safety cables
Product information
Article No. Colour No. of cores x cross section Cu content Total weight Outer diameter Fire load
188 368
188 369
188 370
188 371
red
white
red
white
n x mm2
2
2
2
2
x
x
x
x
1,5
1,5
2,5
2,5
kg/km
43
43
72
72
app. kg/km
98
98
141
141
app. mm
8,3
8,3
9,7
9,7
kWh/m
0,19
0,19
0,26
0,26
Information
Accessories
Distribution boxes
Firestop systems
Fixing devices
Support systems
51
Inner sheath
Polyolefin compound
Sheath
FRNC/LS0H
Shielding
Alu-laminated
tape
Drain wire
Tinned
copper
Insulation
Fire resistant
special compound
Conductor
Solid
Application
Armoured cable for fire alarm systems and emergency lighting for permament installation in buildings.
Permitted operating temperature at conductor of +90C.
Construction
Conductor
Insulation
Core colours
Inner covering
Shielding
Inner sheath
Armouring
Outer Sheath
Sheath colour
Imprint
Electrical Properties
Nominal voltage
Test voltage
300/500V
2000V, 50Hz
General Properties
Zero halogen,
non corrosive gases
Flame propagation
Flame spread
Smoke density
Circuit integrity [FE/PH]
Firestop systems
Fixing devices
Support systems
Safety cables
Product information
Distribution boxes
Accessories
Information
52
Armouring
galvanised
steel wire braid
Inner covering
Glass fibre
tape
Safety cables
Product information
Article No. Colour No. of cores x cross section Cu content Total weight Outer diameter Fire load
184 580
red
red
n x mm2
2
2
x
x
1,5
2,5
kg/km
48
72
app. kg/km
190
250
app. mm
12,0
13,0
kWh/m
0,40
0,50
Information
Accessories
Distribution boxes
Firestop systems
Fixing devices
Support systems
53
FE180
Filler
Flame retardant,
zero halogen
Sheath
FRNC/LS0H
Insulation
Crosslinked polymer
zero halogen
Conductor
Solid/stranded
Application
Safety cables are used in all situations that require special protection against fire and flame damage
for people and equipment and where a high degree of safety conditions must be fulfilled. Suitable
for indoor applications. For outdoor applications, protection must be provided against exposure to
direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used.
Permitted operating temperature at conductor +90C.
Construction
Conductor
Insulation
Filler
Outer sheath
Core colours
Sheath colour
Imprint
Electrical Properties
Nominal voltage
Test voltage
0.6/1kV
3500V, 50Hz
General Properties
Distribution boxes
Firestop systems
Fixing devices
Support systems
Safety cables
Product information
Zero halogen,
non corrosive gases
Flame propagation
Flame spread
Smoke density
Circuit integrity [FE/PH]
Accessories
Information
54
Fire barrier
High-peformance
Keram compound
FE180
Safety cables
Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
154
240
336
480
672
912
1152
1440
1776
2304
227
329
428
565
783
1054
1281
1606
1983
2607
app. mm
9,8
11,3
12,4
13,9
15,7
18,1
19,2
21,4
23,6
26,8
kWh/m
0,34
0,43
0,48
0,58
0,68
0,91
0,97
1,20
1,46
1,81
191 118
191 119
186 952
190 404
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240
RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
29
48
77
115
192
307
480
672
960
1334
1824
2304
2880
3552
4608
103
144
202
272
407
661
950
1219
1602
2218
2974
3563
4450
5514
7232
7,8
9,0
10,4
11,8
14,0
18,2
21,2
23,4
26,4
30,4
35,0
37,4
41,6
46,2
52,6
0,22
0,28
0,37
0,46
0,63
1,09
1,42
1,66
2,06
2,61
3,46
3,87
4,75
5,86
7,46
187 180
187 184
187 187
187 189
186 953
186 955
186 957
186 959
186 961
RE = circular, solid conductor
RM = circular, stranded conductor
3
3
3
3
3
3
3
3
3
3
x 1,5
x 2,5
x
4
x
6
x 10
x 16
x 25
x 35
x 50
x 70
RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
43
72
115
173
288
461
720
1008
1440
2016
122
171
243
333
502
811
1184
1529
2026
2844
8,3
9,5
11,0
12,5
14,8
19,3
22,6
24,9
28,2
32,7
0,25
0,31
0,41
0,51
0,69
1,19
1,56
1,80
2,24
2,88
Support systems
16
25
35
50
70
95
120
150
185
240
Fixing devices
x
x
x
x
x
x
x
x
x
x
Firestop systems
app. kg/km
1
1
1
1
1
1
1
1
1
1
Distribution boxes
kg/km
171 370
171 377
171 386
171 394
171 429
170 842
170 845
170 850
170 855
170 858
Accessories
n x mm2
Information
55
FE180
Safety cables
Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
56
n x mm2
kg/km
app. kg/km
187 182
190 502
192 352
192 353
186 967
186 968
186 969
186 970
186 971
186 972
186 973
186 974
187 548
187 077
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240
RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
58
96
154
230
384
614
960
1344
1920
2688
3648
4608
5760
7104
9216
148
212
304
414
635
1009
1485
1929
2600
3618
4860
5890
7417
9164
12029
9,1
10,5
12,2
13,8
16,4
21,1
24,8
27,4
31,5
36,2
41,7
44,6
50,0
55,3
63,0
0,29
0,38
0,49
0,61
0,85
1,40
1,86
2,15
2,79
3,38
4,68
5,19
6,52
7,98
10,05
187 183
187 186
187 188
187 190
186 975
186 976
186 977
186 978
186 979
190 587
RE = circular, solid conductor
RM = circular, stranded conductor
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240
RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
72
120
192
288
480
768
1200
1680
2400
3360
4560
5760
7200
8880
11520
178
261
371
509
777
1223
1806
2384
3187
4440
6032
7290
9145
11284
14632
9,9
11,6
13,4
15,2
18,1
23,1
27,2
30,5
34,8
40,0
46,6
49,7
55,5
61,3
69,8
0,35
0,47
0,61
0,76
1,03
1,67
2,22
2,66
3,41
4,26
5,89
6,49
8,08
9,84
12,44
Information
Accessories
Distribution boxes
Firestop systems
Fixing devices
Support systems
app. mm
kWh/m
FE180
Safety cables
Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
app. mm
kWh/m
x 1,5
x 2,5
x
4
x
6
x 10
RE
RE
RE
RE
RE
101
168
269
403
672
222
322
464
652
1022
10,8
12,5
14,5
16,7
20,3
0,41
0,53
0,7
0,89
1,27
187 108
8
8
x 1,5
x 2,5
RE
RE
115
192
260
384
11,9
13,8
0,48
0,62
188 345
10
10
x 1,5
x 2,5
RE
RE
144
240
321
465
13,8
16,0
0,69
0,77
186 269
192 479
12
12
x 1,5
x 2,5
RE
RE
173
288
365
541
14,2
16,7
0,66
0,88
187 109
21
21
x 1,5
x 2,5
RE
RE
303
504
580
883
17,7
21,0
0,99
1,35
190 412
RE = circular, solid conductor
RM = circular, stranded conductor
27
27
x 1,5
x 2,5
RE
RE
389
648
755
1122
20,4
23,9
1,3
1,7
Information
Accessories
Support systems
app. kg/km
7
7
7
7
7
Fixing devices
kg/km
186 267
186 268
187 201
Firestop systems
n x mm2
Distribution boxes
57
FE180 flex
Filler
Flame retardant,
zero halogen
Sheath
FRNC/LS0H
Conductor
flexible
Safety cables are used in all situations that require special protection against fire and flame damage
for people and equipment and where a high degree of safety conditions must be fulfilled. Suitable
for indoor applications. For outdoor applications, protection must be provided against exposure to
direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used.
Permitted operating temperature at conductor +90C.
Construction
Conductor
Insulation
Filler
Outer sheath
Core colours
Sheath colour
Imprint
Electrical Properties
Nominal voltage
Test voltage
300/500V
2000V, 50Hz
General Properties
permanent installation
during installation
permanent installation
during installation
Zero halogen,
non corrosive gases
Flame propagation
Flame spread
Smoke density
Circuit integrity [FE/PH]
Safety cables
Firestop systems
Fixing devices
Support systems
Application
Distribution boxes
pyrofil Keram FE180 flex 0511/e
Accessories
Information
Insulation
Crosslinked polymer
zero halogen
Product information
58
Fire barrier
High performance
Keram
special compound
4 x D (D = outer diameter)
6xD
-45C to +90C
-5C to +50C
FE180 flex
Safety cables
Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
3
4
5
5
5
5
7
8
12
16
21
x
x
x
x
x
x
x
x
x
x
x
1,5
4,0
1,5
2,5
4,0
6,0
1,5
1,5
1,5
1,5
1,5
kg/km
43
154
72
120
192
288
101
115
173
231
303
app. kg/km
123
345
182
268
419
580
221
272
310
406
521
app. mm
9
14
10
12
15
18
11
13
14
16
18
kWh/m
0,27
0,54
0,4
0,55
0,65
0,80
0,44
0,56
0,72
0,89
1,10
Information
Accessories
Distribution boxes
Firestop systems
Fixing devices
188 335
187 554
187 179
192 367
185 228
191 059
191 060
191 061
Additional dimensions available on request.
n x mm2
Support systems
59
FE180-CL
Polyolefin
flame retardant, low
smoke, zero halogen
Sheath
FRNC/LS0H
Armouring
Galvanised
steel tape
Fire barrier
High-peformance
Keram compound
Insulation
Crosslinked polymer
zero halogen
Conductor
Solid/stranded
Application
Safety cables are used in all situations that require special protection against fire and flame damage
for people and equipment and where a high degree of safety conditions must be fulfilled. Suitable
for indoor applications. For outdoor applications, protection must be provided against exposure to
direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used.
Permitted operating temperature at conductor +90C.
Construction
Conductor
Insulation
Filler
Inner sheath
Armouring
[rodent protection]
Outer sheath
Core colours
Sheath colour
Imprint
Electrical Properties
Nominal voltage
Test voltage
0.6/1kV
3500V, 50Hz
General Properties
Distribution boxes
Firestop systems
Fixing devices
Support systems
Safety cables
Product information
Zero halogen,
non corrosive gases
Flame propagation
Flame spread
Smoke density
Circuit integrity [FE/PH]
Accessories
Information
60
Filler
Flame retardant,
zero halogen
Single core cable with copper tape [CLCU] and multicore cable
with galvanised steel tape [CL]
Compound, HD 604 S1 part 5 H
CENELEC HD 308 S2
Orange
On request
FE180-CL
Safety cables
Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
x
x
x
x
x
x
x
x
x
x
x
x
x
1,5
2,5
4,0
6,0
10
16
25
35
50
70
95
120
150
RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM
RM
RM
kg/km
app. kg/km
43
72
115
173
288
461
720
1008
1440
2016
2736
3456
4320
211
256
373
487
656
1075
1491
1865
2404
3314
4369
5222
6460
app. mm
11
12
14
16
18
24
27
29
32
37
42
45
50
kWh/m
0,46
0,50
0,69
0,90
1,20
1,93
2,41
2,73
3,29
4,22
5,42
6,04
7,30
Information
Accessories
Distribution boxes
Firestop systems
3
3
3
3
3
3
3
3
3
3
3
3
3
Support systems
187 199
191 097
191 121
188 354
188 327
RE = circular, solid conductor
RM = circular, stranded conductor
n x mm2
Fixing devices
61
FE180-CL
Safety cables
Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
kg/km
app. kg/km
4
4
4
4
4
4
4
4
4
4
4
4
4
x
x
x
x
x
x
x
x
x
x
x
x
x
1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM
RM
RM
58
96
154
230
384
614
960
1344
1920
2688
3648
4608
5760
251
336
454
538
872
1296
1820
2296
3035
4044
5426
6494
8140
12
14
16
17
21
25
29
32
36
40
46
49
54
0,54
0,56
0,79
1,06
1,48
2,20
2,78
3,16
4,02
5,05
6,52
7,26
8,72
187 202
191 038
188 350
188 353
188 397
187 154
186 984
187 132
187 131
RE = circular, solid conductor
RM = circular, stranded conductor
5
5
5
5
5
5
5
5
5
5
5
x 1,5
x 2,5
x
4
x
6
x 10
x 16
x 25
x 35
x 50
x 70
x 95
RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM
72
120
192
288
480
768
1200
1680
2400
3360
4560
260
360
489
647
971
1536
2171
2808
3686
5053
6792
12
14
16
18
21
27
31
35
39
45
52
0,58
0,76
1,05
1,28
1,76
2,53
3,23
3,85
4,83
6,05
8,14
Information
62
n x mm2
191 595
187 167
188 352
186 980
186 981
186 982
190 589
192 488
192 429
192 430
Accessories
Distribution boxes
Firestop systems
Fixing devices
Support systems
app. mm
kWh/m
FE180-CL
Safety cables
Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
app. mm
kWh/m
x 1,5
x 2,5
x
4
x
6
x 10
RE
RE
RE
RE
RE
101
168
269
403
672
349
481
655
803
1214
14
16
18
19
23
0,72
0,91
1,15
1,53
2,13
192 461
187 128
191 104
8
8
8
x 1,5
x 2,5
x
4
RE
RE
RE
115
192
308
406
493
684
15
16
18
0,85
1,04
1,36
10
10
x 1,5
x 2,5
RE
RE
144
240
498
677
18
20
1,05
1,32
12
12
x 1,5
x 2,5
RE
RE
173
288
546
781
18
21
1,12
1,52
21
21
x 1,5
x 2,5
RE
RE
303
504
849
1218
22
26
1,71
2,29
RE = circular, solid conductor
RM = circular, stranded conductor
27
27
x 1,5
x 2,5
RE
RE
389
648
1075
1527
25
29
2,16
2,87
Information
Accessories
Support systems
app. kg/km
7
7
7
7
7
Fixing devices
kg/km
188 355
188 356
Firestop systems
n x mm2
Distribution boxes
63
FE180 E30-E60
Filler
Flame retardant,
zero halogen
Sheath
FRNC/LS0H
Insulation
Crosslinked polymer
zero halogen
Conductor
Solid/
stranded
Application
Safety cables are used in all situations that require special protection against fire and flame damage
for people and equipment and where a high degree of safety conditions must be fulfilled. Suitable
for indoor applications. For outdoor applications, protection must be provided against exposure to
direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used.
These cables correspond to the demands of System Circuit integrity E30-E60* in accordance with
DIN 4102-12. System Circuit integrity is guaranteed at an operating voltage up to 400V.
Permitted operating temperature at conductor +90C.
Construction
Conductor
Insulation
Filler
Outer sheath
Core colours
Sheath colour
Imprint
Electrical Properties
Rated voltage
Test voltage
0.6/1kV
4000V, 50Hz
General Properties
Firestop systems
Fixing devices
Support systems
Safety cables
Product information
Distribution boxes
Accessories
Information
64
Fire barrier
High-peformance
Keram compound
FE180 E30-E60
Safety cables
Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
4
6
10
16
25
35
50
70
95
120
150
185
240
RE
RE
RE
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
38
58
96
154
240
336
480
672
912
1152
1440
1776
2304
90
113
158
227
329
428
565
783
1054
1279
1604
1981
2604
app. mm
7,1
7,6
8,4
9,8
11,3
12,4
13,9
15,7
18,1
19,2
21,4
23,6
26,8
kWh/m
0,21
0,23
0,27
0,34
0,43
0,48
0,58
0,68
0,91
0,97
1,20
1,46
1,81
186 280
186 921
186 922
186 923
186 924
186 952
187 221
2
2
2
2
2
2
2
x 1,5
x 2,5
x
4
x
6
x 10
x 16
x 25
RE
RE
RE
RE
RE
RM
RM
29
48
77
115
192
307
480
178
217
272
337
459
661
950
11,0
11,8
12,8
13,8
15,4
18,2
21,2
0,48
0,54
0,62
0,70
0,83
1,09
1,42
186 925
186 926
186 927
186 928
186 929
186 953
186 955
186 957
186 959
186 961
RE = circular, solid conductor
RM = circular, stranded conductor
3
3
3
3
3
3
3
3
3
3
x 1,5
x 2,5
x
4
x
6
x 10
x 16
x 25
x 35
x 50
x 70
RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
43
72
115
173
288
461
720
1008
1440
2016
200
250
319
403
560
811
1184
1529
2026
2844
11,5
12,4
13,5
14,6
16,3
19,3
22,6
24,9
28,2
32,7
0,53
0,60
0,68
0,77
0,91
1,19
1,56
1,80
2,24
2,88
Support systems
x
x
x
x
x
x
x
x
x
x
x
x
x
Fixing devices
app. kg/km
1
1
1
1
1
1
1
1
1
1
1
1
1
Firestop systems
kg/km
171 289
171 290
171 291
171 370
171 377
171 386
171 394
171 429
170 842
170 845
170 850
170 855
170 858
Distribution boxes
n x mm2
Accessories
Information
65
FE180 E30-E60
Safety cables
Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
186 930
186 931
186 932
186 933
186 934
186 967
186 968
186 969
186 970
186 971
186 972
186 973
186 974
187 548
187 077
RE = circular, solid conductor
RM = circular, stranded conductor
Information
66
3
3
3
3
3
3
3
3
x
x
x
x
x
x
x
x
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
Accessories
Distribution boxes
Firestop systems
Fixing devices
Support systems
186 954
186 956
186 958
186 960
186 962
186 963
186 964
186 965
n x mm2
25 + 1
35 + 1
50 + 1
70 + 1
95 + 1
120 + 1
150 + 1
185 + 1
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240
x
x
x
x
x
x
x
x
16
16
25
35
50
70
70
95
RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
kg/km
app. kg/km
874
1162
1680
2352
3216
4128
4992
6240
1361
1692
2311
3171
4276
5303
6417
8040
app. mm
23,9
25,9
29,9
34,0
39,3
42,6
46,6
52,0
kWh/m
1,73
1,93
2,52
3,07
4,18
4,74
5,63
6,99
58
96
154
230
384
614
960
1344
1920
2688
3648
4608
5760
7104
9216
234
296
381
490
695
1009
1485
1929
2600
3618
4860
5890
7417
9160
12043
12,4
13,4
14,6
15,8
17,8
21,1
24,8
27,4
31,5
36,2
41,7
44,6
50,0
55,3
63,0
0,61
0,69
0,78
0,90
1,07
1,40
1,86
2,15
2,79
3,38
4,68
5,19
6,52
7,98
10,05
FE180 E30-E60
Safety cables
Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM
72
120
192
288
480
768
1200
1680
2400
3360
4560
278
353
456
589
832
1223
1806
2384
3187
4440
6032
13,4
14,5
15,8
17,2
19,3
23,1
27,2
30,5
34,8
40,0
46,6
0,71
0,81
0,93
1,05
1,25
1,67
2,22
2,66
3,41
4,26
5,89
171 272
171 273
7
7
x 1,5
x 2,5
RE
RE
101
168
331
426
14,4
15,6
0,81
0,92
171 279
171 280
12
12
x 1,5
x 2,5
RE
RE
173
288
513
675
18,3
20,0
1,20
1,37
171 283
171 284
19
19
x 1,5
x 2,5
RE
RE
274
456
715
953
21,2
23,2
1,63
1,83
171 285
171 286
24
24
x 1,5
x 2,5
RE
RE
346
576
901
1205
24,6
27,0
1,99
2,27
171 287
171 288
RE = circular, solid conductor
RM = circular, stranded conductor
30
30
x 1,5
x 2,5
RE
RE
432
720
1057
1446
26,0
28,8
2,28
2,68
kWh/m
Information
app. mm
Support systems
x 1,5
x 2,5
x
4
x
6
x 10
x 16
x 25
x 35
x 50
x 70
x 95
Fixing devices
app. kg/km
5
5
5
5
5
5
5
5
5
5
5
Firestop systems
kg/km
186 935
186 936
186 937
186 938
186 939
186 975
186 976
186 977
186 978
186 979
190 587
Distribution boxes
n x mm2
Accessories
67
Sheath
FRNC/LS0H
Separator
Plastic tape
Reinforcing
helix
Bare copper
tape
Insulation
Crosslinked polymer
zero halogen
Filler
Flame retardant,
zero halogen
Conductor
Solid/stranded
Fire barrier
High-peformance
Keram compound
Application
Safety cables are used in all situations that require special protection against fire and flame damage
for people and equipment and where a high degree of safety conditions must be fulfilled. Suitable
for indoor applications. For outdoor applications, protection must be provided against exposure to
direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used.
These cables correspond to the demands of System Circuit integrity E30-E60* in accordance with
DIN 4102-12. System Circuit integrity is guaranteed at an operating voltage up to 400V.
Permitted operating temperature at conductor +90C.
Construction
Conductor
Insulation
Filler
Concentric conductor
Separator
Outer sheath
Core colours
Sheath colour
Imprint
Electrical Properties
Nominal voltage
Test voltage
0.6/1kV
4000V, 50Hz
General Properties
Firestop systems
Fixing devices
Support systems
Safety cables
Product information
Distribution boxes
Accessories
Information
68
Concentric conductor
Bare copper
wire
Safety cables
Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
RE/1,5
RE/2,5
RE/4
RE/6
RE/10
52
80
123
182
312
224
273
355
436
622
12,7
13,5
15,0
16,0
18,0
0,60
0,66
0,78
0,86
1,07
186 945
186 946
187 233
187 235
187 237
187 238
187 239
187 240
187 241
187 242
186 985
186 986
186 987
187 243
186 988
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240
RE/1,5
RE/2,5
RE/4
RE/6
RE/10
RM/16
RM/16
RM/16
RM/25
RM/35
RM/50
RM/70
RM/70
RM/95
RM/120
66
104
161
240
408
643
902
1190
1723
2410
3296
4236
5100
6383
8242
248
308
404
504
727
1148
1437
1796
2408
3381
4513
5576
6799
8300
11065
13,2
14,1
15,7
16,8
18,9
23,9
25,0
27,3
30,8
36,0
41,1
44,5
49,2
56,0
61,5
0,65
0,72
0,84
0,94
1,15
1,63
1,90
2,20
2,84
3,52
4,66
5,30
6,46
7,90
9,93
186 947
186 948
186 949
186 950
186 951
186 989
186 990
186 991
186 992
186 993
186 994
186 995
186 996
186 997
186 998
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240
RE/1,5
RE/2,5
RE/4
RE/6
RE/10
RM/16
RM/16
RM/16
RM/25
RM/35
RM/50
RM/70
RM/70
RM/95
RM/120
81
128
200
297
504
796
1142
1526
2203
3082
4208
5388
6540
8159
10546
286
358
473
621
868
1254
1752
2210
3049
4198
5600
6940
8500
10615
13830
14,1
15,1
16,8
18,1
20,1
23,4
27,2
29,8
34,8
39,5
45,2
49,1
54,3
59,8
67,9
0,73
0,82
0,96
1,13
1,33
1,70
2,20
2,56
3,41
4,18
5,58
6,37
7,83
9,55
12,00
187 244
1,5
RE/2,5
133
393
16,1
0,94
499
1252
29,1
2,67
187 245
30 x
1,5
RE/6
RE = circular, solid conductor, RM = circular, stranded conductor
Additional dimensions available on request. * Circuit integrity is dependent on installation method
Support systems
kWh/m
1,5
2,5
4
6
10
Fixing devices
app. mm
x
x
x
x
x
Firestop systems
app. kg/km
2
2
2
2
2
Distribution boxes
kg/km
186 943
186 944
187 232
187 234
187 236
Accessories
n x mm2
Information
69
Sheath
FRNC/LS0H
Inner sheath
Polyolefin
flame retardant,
low smoke,
zero halogen
Fire barrier
High performance
Keram
special compound
Insulation
Crosslinked polymer
zero halogen
Conductor
Solid/stranded
Application
Safety cables are used in all situations that require special protection against fire and flame damage
for people and equipment and where a high degree of safety conditions must be fulfilled. Suitable
for indoor applications. For outdoor applications, protection must be provided against exposure to
direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used.
These cables correspond to the demands of circuit integrity E30-E60* in accordance with DIN 4102-12.
Circuit integrity is guaranteed at an operating voltage up to 400V.
Permitted operating temperature at conductor +90C.
Construction
Conductor
Insulation
Filler
Inner sheath
Armouring
[rodent protection]
Outer sheath
Core colours
Sheath colour
Imprint
Electrical Properties
Nominal voltage
Test voltage
0.6/1kV
4000V, 50Hz
General Properties
Firestop systems
Fixing devices
Support systems
Safety cables
Product information
Distribution boxes
Accessories
Information
70
Armouring
Galvanised
steel tape
Filler
Flame retardant
zero halogen
Safety cables
Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM
RM
RM
RM
29
48
77
115
192
307
480
672
960
1344
1824
2304
2880
3552
336
385
453
531
673
911
1239
1536
1956
2640
3476
4119
5087
6268
15
16
17
18
20
22
25
28
31
35
40
42
47
52
0,94
1,02
1,13
1,25
1,43
1,79
2,22
2,64
3,04
3,79
4,89
5,47
6,62
8,13
191 107
186 940
192 351
188 326
191 597
188 327
RE = circular, solid conductor
RM = circular, stranded conductor
3
3
3
3
3
3
3
3
3
3
3
3
3
x
x
x
x
x
x
x
x
x
x
x
x
x
1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM
RM
RM
43
72
115
173
288
461
720
1008
1440
2016
2736
3456
4320
364
426
509
607
785
1075
1491
1865
2404
3315
4369
5222
6460
16
17
18
19
21
24
27
29
32
37
42
45
50
1,00
1,10
1,22
1,35
1,54
1,93
2,41
2,73
3,29
4,22
5,42
6,04
7,30
kWh/m
Information
app. mm
Support systems
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Fixing devices
app. kg/km
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Firestop systems
kg/km
192 350
187 562
191 612
187 563
Distribution boxes
n x mm2
Accessories
71
Safety cables
Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
72
n x mm2
kg/km
app. kg/km
190 590
191 102
186 980
186 981
186 982
190 589
4
4
4
4
4
4
4
4
4
4
4
4
x 1,5
x 2,5
x
4
x
6
x 10
x 16
x 25
x 35
x 50
x 70
x 95
x 120
RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM
RM
58
96
154
230
384
614
960
1344
1920
2688
3648
4608
410
485
585
710
940
1296
1820
2296
3037
4157
5498
6595
17
18
19
20
22
25
29
32
36
41
47
50
1,11
1,22
1,36
1,51
1,76
2,2
2,78
3,16
4,02
5,05
6,52
7,26
192 347
188 117
188 118
186 941
186 942
190 525
186 984
190 529
191 565
5
5
5
5
5
5
5
5
5
5
5
x 1,5
x 2,5
x
4
x
6
x 10
x 16
x 25
x 35
x 50
x 70
x 95
RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM
72
120
192
288
480
768
1200
1680
2400
3360
4560
466
556
676
826
1096
1460
2171
2730
3620
5054
6792
18
19
20
21
24
26
31
35
39
45
52
1,25
1,38
1,54
1,72
1,98
2,53
3,23
3,85
4,83
6,05
8,14
188 094
RE = circular, solid conductor
RM = circular, stranded conductor
6
6
6
6
6
x 1,5
x 2,5
x
4
x
6
x 10
RE
RE
RE
RE
RE
86
144
230
346
576
521
625
693
943
1269
19
20
20
23
25
1,39
1,54
1,74
1,94
2,26
Information
Accessories
Distribution boxes
Firestop systems
Fixing devices
Support systems
app. mm
kWh/m
Safety cables
Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
101
168
269
403
672
532
643
799
987
1343
19
20
21
23
25
1,38
1,53
1,71
1,9
2,2
188 095
8
8
8
x 1,5
x 2,5
x
4
RE
RE
RE
115
192
307
605
732
916
20
21
23
1,53
1,69
1,91
10
10
10
x 1,5
x 2,5
x
4
RE
RE
RE
144
240
384
701
858
1080
22
24
26
1,78
1,98
2,24
185 239
12
12
12
x 1,5
x 2,5
x
4
RE
RE
RE
173
288
461
764
873
1205
23
23
26
1,9
2,13
2,42
14
14
x 1,5
x 2,5
RE
RE
202
336
847
1062
23
25
2,07
2,34
185 233
16
16
x 1,5
x 2,5
RE
RE
231
384
926
1155
24
26
2,24
2,52
21
21
x 1,5
x 2,5
RE
RE
303
504
1093
1381
27
29
2,58
2,89
27
27
x 1,5
x 2,5
RE
RE
389
648
1311
1681
29
32
3,06
3,45
185 235
30
x 1,5
185 241
30
x 2,5
RE = circular, solid conductor, RM = circular, stranded conductor
Additional dimensions available on request.
* Circuit integrity is dependent on installation method
RE
RE
432
720
1407
1848
30
33
3,25
3,81
Support systems
kWh/m
RE
RE
RE
RE
RE
Fixing devices
app. mm
x 1,5
x 2,5
x
4
x
6
x 10
Firestop systems
app. kg/km
7
7
7
7
7
Distribution boxes
kg/km
185 232
185 245
185 247
185 248
Accessories
n x mm2
Information
73
Filler
Flame retardant,
zero halogen
Sheath
FRNC/LS0H
Electrical Properties
Nominal voltage
Test voltage
0.6/1kV
4000V, 50Hz
General Properties
Safety cables
Support systems
Fixing devices
Firestop systems
Safety cables are used in all situations that require special protection against fire and flame damage
for people and equipment and where a high degree of safety conditions must be fulfilled. Suitable
for indoor applications. For outdoor applications, protection must be provided against exposure to
direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used.
These cables correspond to the demands of System Circuit integrity E90 in accordance with
DIN 4102-12. System Circuit integrity is guaranteed at an operating voltage up to 400V.
Permitted operating temperature at conductor +90C.
Bare copper, solid or stranded, IEC 60228, EN 60228, (VDE 0295)
Double insulation, cross-linked, high-performance Keram
special compound, VDE 0266 HXI1
Flame retardant, halogen-free, thermoplastic compound
Flame retardant Polyolefin compound,
CENELEC HD 604 S1 and VDE 0276-604 HM4
CENELEC HD 308 S2 and VDE 0293
Orange
Datwyler PYROFIL KERAM (N)HXH FE180 E90 1kV N X MM2
VDE REG. NR. 7780 Vds ORDER NO. SWISS MADE YEAR
METRE MARKING
or on request
Distribution boxes
Accessories
Conductor
Solid/
stranded
Conductor
Insulation
Filler
Outer sheath
Core colours
Sheath colour
Imprint
Construction
Information
Insulation
Crosslinked polymer
zero halogen
Product information
Application
74
Fire barrier
High-peformance
Keram compound
Safety cables
Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
154
240
336
480
672
912
1152
1440
1776
2304
2880
243
347
449
589
810
1090
1318
1648
2029
2658
3166
app. mm
10,2
11,7
12,8
14,3
16,1
18,5
19,6
21,8
24,0
27,2
29,6
kWh/m
0,35
0,43
0,49
0,58
0,67
0,85
0,91
1,11
1,32
1,63
1,91
188 359
187 247
187 248
187 249
187 250
187 254
187 255
187 256
187 257
187 258
187 259
187 260
2
2
2
2
2
2
2
2
2
2
2
2
x 1,5
x 2,5
x
4
x
6
x 10
x 16
x 25
x 35
x 50
x 70
x 95
x 120
RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM
RM
29
48
77
115
192
307
480
672
960
1344
1824
2304
178
217
272
337
459
714
1011
1287
1742
2346
3130
3729
11,0
11,8
12,8
13,8
15,4
19,0
22,0
24,2
28,0
31,6
36,2
38,6
0,48
0,54
0,62
0,70
0,83
1,19
1,54
1,79
2,35
2,86
3,67
4,11
186 174
3
x 1,5
186 177
3
x 2,5
186 182
3
x
4
186 186
3
x
6
186 189
3
x 10
186 152
3
x 16
186 153
3
x 25
186 154
3
x 35
186 207
3
x 50
187 261
3
x 70
187 262
3
x 95
187 263
3
x 120
187 264
3
x 150
187 265
3
x 185
187 266
3
x 240
RE = circular, solid conductor, RM = circular, stranded conductor
RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
43
72
115
173
288
461
720
1008
1440
2016
2736
3456
4320
5328
6912
200
250
319
403
560
878
1299
1664
2189
2997
4007
4812
5988
7363
9632
11,5
12,4
13,5
14,6
16,3
20,2
24,0
26,4
29,8
33,9
38,9
41,5
46,0
50,7
57,6
0,53
0,60
0,68
0,77
0,91
1,29
1,75
2,02
2,51
3,09
3,95
4,39
5,32
6,44
8,10
Support systems
16
25
35
50
70
95
120
150
185
240
300
Fixing devices
x
x
x
x
x
x
x
x
x
x
x
Firestop systems
app. kg/km
1
1
1
1
1
1
1
1
1
1
1
Distribution boxes
kg/km
186 141
186 142
186 143
186 144
186 145
186 146
186 147
186 148
186 149
186 150
186 151
Accessories
n x mm2
Information
75
Safety cables
Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
186 175
186 178
186 183
186 187
186 190
186 155
186 156
186 157
186 158
186 159
186 160
187 274
186 161
187 275
190 493
RE = circular, solid conductor
RM = circular, stranded conductor
Additional dimensions available on request.
Information
Accessories
Distribution boxes
Firestop systems
Fixing devices
Support systems
191 069
191 002
191 003
191 004
191 005
191 006
191 008
76
n x mm2
3
3
3
3
3
3
3
x
x
x
x
x
x
x
35 + 1
50 + 1
70 + 1
95 + 1
120 + 1
150 + 1
185 + 1
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240
16
25
35
50
70
70
95
RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
kg/km
app. kg/km
1162
1680
2352
3216
4128
4992
6240
1833
2457
3362
4488
5532
6666
8315
app. mm
27,4
31,3
35,6
40,7
44,0
48,0
53,4
kWh/m
2,13
2,69
3,34
4,24
4,82
5,70
7,00
58
96
154
230
384
614
960
1344
1920
2688
3648
4608
5760
7104
9216
234
296
381
490
695
1089
1618
2083
2752
3804
5092
6133
7662
9425
12334
12,4
13,4
14,6
15,8
17,8
22,1
26,3
29,0
32,8
37,6
43,1
46,0
51,2
56,5
64,1
0,61
0,69
0,78
0,90
1,07
1,54
2,05
2,36
2,97
3,55
4,75
5,27
6,49
7,85
9,85
Safety cables
Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
x 1,5
x 2,5
x
4
x
6
x 10
x 16
x 25
x 35
x 50
x 70
RE
RE
RE
RE
RE
RM
RM
RM
RM
RM
72
120
192
288
480
768
1200
1680
2400
3360
278
353
456
589
832
1361
1960
2547
3392
4667
13,4
14,5
15,8
17,2
19,3
24,8
28,8
32,0
36,5
41,5
0,71
0,81
0,93
1,05
1,25
1,86
2,42
2,86
3,68
4,51
185 271
186 180
186 185
7
7
7
x 1,5
x 2,5
x
4
RE
RE
RE
101
168
269
331
426
563
14,4
15,6
17,1
0,81
0,92
1,05
172 260
187 253
10
10
x 1,5
x 2,5
RE
RE
144
240
457
593
17,8
19,4
1,09
1,24
185 272
186 181
12
12
x 1,5
x 2,5
RE
RE
173
288
513
675
18,3
20,0
1,20
1,37
185 273
RE = circular, solid conductor
RM = circular, stranded conductor
24
x 1,5
RE
346
901
24,6
1,99
kWh/m
Information
Accessories
app. mm
Support systems
app. kg/km
5
5
5
5
5
5
5
5
5
5
Fixing devices
kg/km
186 176
186 179
186 184
186 188
186 191
186 162
186 163
186 164
186 165
187 277
Firestop systems
n x mm2
Distribution boxes
77
Sheath
FRNC/LS0H
Reinforcing
helix
Bare copper tape
Insulation
Crosslinked polymer
zero halogen
Filler
Flame retardant,
zero halogen
Conductor
Solid/stranded
Fire barrier
High-peformance
Keram compound
Application
Safety cables are used in all situations that require special protection against fire and flame damage
for people and equipment and where a high degree of safety conditions must be fulfilled. Suitable
for indoor applications. For outdoor applications, protection must be provided against exposure to
direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used.
These cables correspond to the demands of System Circuit integrity E90 in accordance with
DIN 4102-12. System Circuit integrity is guaranteed at an operating voltage up to 400V.
Permitted operating temperature at conductor +90C.
Construction
Conductor
Insulation
Filler
Concentric conductor
Separator
Outer sheath
Core colours
Sheath colour
Imprint
Electrical Properties
Nominal voltage
Test voltage
0.6/1kV
4000V, 50Hz
General Properties
Firestop systems
Fixing devices
Support systems
Safety cables
Product information
Distribution boxes
Accessories
Information
78
Separator
Plastic tape
Concentric conductor
Bare copper
wire
Safety cables
Product information
Article No. No. of cores x cross section Cu content Total weight Outer diameter Fire load
RE/1,5
RE/2,5
RE/4
RE/6
RE/10
RM/16
RM/16
RM/16
RM/25
RM/35
RM/50
RM/70
RM/70
RM/95
RM/120
66
104
161
240
408
643
902
1190
1723
2410
3296
4236
5100
6383
8242
248
308
404
504
727
1166
1496
1820
2493
3350
4570
5620
6850
8350
11100
13,2
14,1
15,7
16,8
18,6
24,4
25,8
28,2
32,5
36,1
42,0
45,4
50,7
55,0
62,1
0,65
0,72
0,84
0,94
1,15
1,64
1,95
2,25
2,90
3,42
4,50
5,02
6,00
7,10
9,08
186 072
186 196
186 198
186 199
186 200
186 131
186 132
186 133
186 134
186 135
186 136
186 137
186 138
186 139
186 140
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240
RE/1,5
RE/2,5
RE/4
RE/6
RE/10
RM/16
RM/16
RM/16
RM/25
RM/35
RM/50
RM/70
RM/70
RM/95
RM/120
81
128
200
297
504
796
1142
1526
2203
3082
4208
5388
6540
8159
10546
286
358
473
621
868
1400
1895
2376
3249
4426
5809
7134
8703
10827
14139
14,1
15,1
16,8
18,1
20,1
25,3
28,9
31,6
36,7
41,3
46,4
50,1
55,3
60,8
69,2
0,73
0,82
0,96
1,13
1,33
1,81
2,28
2,60
3,49
4,25
5,53
6,25
7,58
9,18
11,60
7
7
12
12
24
24
30
30
x
x
x
x
x
x
x
x
1,5
2,5
1,5
2,5
1,5
2,5
1,5
2,5
RE/2,5
RE/2,5
RE/2,5
RE/4
RE/6
RE/10
RE/6
RE/10
133
200
205
334
413
696
499
840
393
491
595
798
901
1205
1252
1692
16,1
17,3
20,2
22,6
27,4
30,6
29,1
32,2
0,94
1,05
1,38
1,63
2,32
2,69
2,67
3,11
186 073
191 096
187 415
172 454
187 402
187 403
187 404
187 405
RE = circular, solid conductor
RM = circular, stranded conductor
Additional dimensions available on request.
app. mm
kWh/m
Support systems
1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240
Fixing devices
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Firestop systems
app. kg/km
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
Distribution boxes
kg/km
186 071
186 195
186 197
187 278
187 279
187 251
187 406
172 417
187 408
187 409
187 410
187 411
187 412
187 413
187 414
Accessories
n x mm2
Information
79
Sheath
FRNC/LS0H
Shielding
Al-laminated tape
zero halogen
Drain wire
0,8 mm
Insulation
Crosslinked polymer
zero halogen
Conductor
Solid
Application
Safety cables are used in all situations that require special protection against fire and flame damage
for people and equipment and where a high degree of safety conditions must be fulfilled. Suitable
for indoor applications. For outdoor applications, protection must be provided against exposure to
direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used.
These cables correspond to the demands of System Circuit integrity E30 in accordance with
DIN 4102-12. System Circuit integrity is guaranteed at an operating voltage up to 110V.
Permitted operating temperature at conductor +70C.
Construction
Conductor
Insulation
Core colours
Separator
Shielding
Outer sheath
Sheath colour
Imprint
Electrical Properties
Insulation resistance
Loop resistance
Capacitance unbalance
Capacitance coupling
Rated voltage
Test voltage
min. 100 M x km
max. 73.2 /km at 0.80 mm
max. 120 nF/km at 800 Hz
K max. 200 pF/100m at 800 Hz
max. 225 V
500 V, 50 Hz Core/Core
2000 V, 50Hz, Core/Screen
General Properties
during installation
permanent installation
1000 N/10 cm
10 Impacts
permanent installation
during installation
Zero halogen,
non corrosive gases
Flame propagation
Flame spread
Smoke density
Circuit integrity [FE/PH]
System Circuit integrity [E30]
Firestop systems
Fixing devices
Support systems
Safety cables
Product information
Distribution boxes
Accessories
Information
80
Separator
Plastic tape
zero halogen
Safety cables
Product information
Article No. No. of cores x conductor diameter Cu content Total weight Outer diameter Fire load
188 376
188 318
188 325
n x mm
1
2
4
x
x
x
2
2
2
x
x
x
kg/km
0.80
0.80
0.80
15
25
45
app. kg/km
40
56
96
app. mm
5.5
6.0
8.7
kWh/m
0.095
0.123
0.21
Information
Accessories
Distribution boxes
Firestop systems
Fixing devices
Support systems
81
Sheath
FRNC/LS0H
Drain wire
0,8 mm
Conductor
Solid
Safety cables are used in all situations that require special protection against fire and flame damage
for people and equipment and where a high degree of safety conditions must be fulfilled. Suitable
for indoor applications. For outdoor applications, protection must be provided against exposure to
direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used.
These cables correspond to the demands of System Circuit integrity E30-E90* in accordance with
DIN 4102-12. System Circuit integrity is guaranteed at an operating voltage up to 110V.
Permitted operating temperature at conductor +70C.
Construction
Conductor
Insulation
Core colours
Separator
Shielding
Outer sheath
Sheath colour
Imprint
Insulation resistance
Loop resistance
Capacitance unbalance
Capacitance coupling
Rated voltage
Test voltage
during installation
permanent installation
1000 N/10 cm
10 Impacts
permanent installation
during installation
Safety cables
Fixing devices
Support systems
Application
Firestop systems
Electrical Properties
Distribution boxes
Accessories
Information
Shielding
Al-laminated tape
zero halogen
Insulation
Crosslinked polymer
zero halogen
Product information
General Properties
82
Separator
Plastic tape
zero halogen
Zero halogen,
non corrosive gases
Flame propagation
Flame spread
Smoke density
Circuit integrity [FE/PH]
System Circuit integrity
[E30-E90]*
Safety cables
Product information
Article No. No. of cores x conductor diameter Cu content Total weight Outer diameter Fire load
188 092
188 097
188 099
188 102
188 104
188 106
188 108
188 111
188 113
188 115
x
x
x
x
x
x
x
x
x
x
2
2
2
2
2
2
2
2
2
2
x
x
x
x
x
x
x
x
x
x
kg/km
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
15
25
45
85
126
166
206
326
407
529
app. kg/km
40
56
96
218
270
337
403
570
739
906
app. mm
5.5
6.0
8.7
13.7
14.6
16.0
18.0
21.8
25.3
27.6
kWh/m
0.095
0.123
0.21
0.52
0.58
0.69
0.80
1.02
1.38
1.59
Information
Accessories
Distribution boxes
Firestop systems
Fixing devices
n x mm
1
2
4
8
12
16
20
32
40
52
Support systems
83
Separator
Plastic tape
zero halogen
Insulation
Crosslinked polymer
zero halogen
BRANDMELDEKABEL
Sheath
FRNC/LS0H
Drain wire
0,8 mm
Conductor
Solid
Application
Safety cables are used in all situations that require special protection against fire and flame damage
for people and equipment and where a high degree of safety conditions must be fulfilled. Suitable
for indoor applications. For outdoor applications, protection must be provided against exposure to
direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used.
These cables correspond to the demands of System Circuit integrity E30 in accordance with
DIN 4102-12. System Circuit integrity is guaranteed at an operating voltage up to 110V.
Permitted operating temperature at conductor +70C.
Construction
Conductor
Insulation
Core colours
Separator
Shielding
Outer sheath
Sheath colour
Imprint
Electrical Properties
Insulation resistance
Loop resistance
Capacitance unbalance
Capacitance coupling
Rated voltage
Test voltage
min. 100 M x km
max. 73.2 /km at 0.80 mm
max. 120 nF/km at 800 Hz
K max. 200 pF/100m at 800 Hz
max. 225 V
500 V, 50 Hz Core/Core
2000 V, 50Hz, Core/Screen
General Properties
during installation
permanent installation
1000 N/10 cm
10 Impacts
permanent installation
during installation
Firestop systems
Fixing devices
Support systems
Safety cables
Product information
Distribution boxes
Accessories
Information
84
Shielding
Al-laminated tape
zero halogen
Safety cables
Product information
Article No. No. of cores x conductor diameter Cu content Total weight Outer diameter Fire load
188 377
188 374
188 375
n x mm
1
2
4
x
x
x
2
2
2
x
x
x
kg/km
0.80
0.80
0.80
15
25
45
app. kg/km
40
56
96
app. mm
5.5
6.0
8.7
kWh/m
0.095
0.123
0.21
Information
Accessories
Distribution boxes
Firestop systems
Fixing devices
Support systems
85
Separator
Plastic tape
zero halogen
Insulation
Crosslinked polymer
zero halogen
BRANDMELDEKABEL
Sheath
FRNC/LS0H
Conductor
Solid
Safety cables are used in all situations that require special protection against fire and flame damage
for people and equipment and where a high degree of safety conditions must be fulfilled. Suitable
for indoor applications. For outdoor applications, protection must be provided against exposure to
direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used.
These cables correspond to the demands of System Circuit integrity E30-E90* in accordance with
DIN 4102-12. System Circuit integrity is guaranteed at an operating voltage up to 110V.
Permitted operating temperature at conductor +70C.
Construction
Conductor
Insulation
Core colours
Separator
Shielding
Outer sheath
Sheath colour
Imprint
Insulation resistance
Loop resistance
Capacitance unbalance
Capacitance coupling
Rated voltage
Test voltage
during installation
permanent installation
1000 N/10 cm
10 Impacts
permanent installation
during installation
Zero halogen,
non corrosive gases
Flame propagation
Flame spread
Smoke density
Circuit integrity [FE/PH]
System Circuit integrity
[E30-E90]*
Safety cables
Fixing devices
Support systems
Application
Electrical Properties
Firestop systems
pyrofil JE-H(St)H...Bd FE180/E30-E90 Keram BMK 0511/e
Distribution boxes
Accessories
Information
Drain wire
0,8 mm
Product information
General Properties
86
Shielding
Al-laminated tape
zero halogen
Safety cables
Product information
Article No. No. of cores x conductor diameter Cu content Total weight Outer diameter Fire load
188 093
188 098
188 101
188 103
188 105
188 107
188 109
188 112
188 114
188 116
x
x
x
x
x
x
x
x
x
x
2
2
2
2
2
2
2
2
2
2
x
x
x
x
x
x
x
x
x
x
kg/km
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
15
25
45
85
126
166
206
326
407
529
app. kg/km
40
56
96
218
270
337
403
570
739
906
app. mm
5.5
6.0
8.7
13.7
14.6
16.0
18.0
21.8
25.3
27.6
kWh/m
0.095
0.123
0.21
0.52
0.58
0.69
0.80
1.02
1.38
1.59
Information
Accessories
Distribution boxes
Firestop systems
Fixing devices
n x mm
1
2
4
8
12
16
20
32
40
52
Support systems
87
Fire alarm cable with steel wire braiding max. 225V, pyrofil Keram
Halogen-free, with improved fire characteristics
with reference to VDE 0815
Circuit integrity (FE180) in accordance with VDE 0472-814, IEC 60331, EN 50200
System Circuit integrity E30-E90* in accordance with DIN 4102-12
Separator
Plastic tape
zero halogen
Insulation
Crosslinked polymer
zero halogen
BRANDMELDEKABEL
Sheath
FRNC/LS0H
Shielding
Al-laminated tape
zero halogen
Drain wire
0,8 mm
Conductor
Solid
Application
Safety cables are used in all situations that require special protection against fire and flame damage for
people and equipment and where a high degree of safety conditions must be fulfilled. Suitable for indoor
applications. For outdoor applications, protection must be provided against exposure to direct sunlight.
The fire alarm cables correspond to the demands of System Circuit integrity E30-E90* in accordance
with DIN 4102-12. System Circuit integrity is guaranteed at an operating voltage up to 110V.
The steel wire braiding serves as a form of mechanical protection. Permitted operating temperature
at conductor of +70C.
Construction
Conductor
Insulation
Core colours
Separator
Shielding
Inner sheath
Armouring
Outer sheath
Sheath colour
Imprint
Insulation resistance
Loop resistance
Capacitance unbalance
Capacitance coupling
Rated voltage
Test voltage
Minimum bending radius
Crush resistance
Impact
Operating temperature
Zero halogen,
non corrosive gases
Flame propagation
Flame spread
Smoke density
Circuit integrity [FE/PH]
System Circuit integrity
[E30-E90]*
Fixing devices
Support systems
Safety cables
Product information
Firestop systems
Electrical Properties
Distribution boxes
General Properties
Accessories
Information
88
Armouring
Galvanised steel
wire braid
Fire alarm cable with steel wire braiding max. 225V, pyrofil Keram
Halogen-free, with improved fire characteristics
with reference to VDE 0815
Circuit integrity (FE180) in accordance with VDE 0472-814, IEC 60331, EN 50200
System Circuit integrity E30-E90* in accordance with DIN 4102-12
Safety cables
Product information
Article No. No. of cores x conductor diameter Cu content Total weight Outer diameter Fire load
188 119
188 120
188 127
188 128
188 129
188 346
x
x
x
x
x
x
x
x
2
2
2
2
2
2
2
2
x
x
x
x
x
x
x
x
kg/km
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80
15
25
45
85
126
166
206
326
app. kg/km
94
117
179
404
466
550
640
877
app. mm
8.3
9.0
11.7
18.0
18.9
20.3
22.3
26.5
kWh/m
0.23
0.26
0.39
0.93
1.01
1.16
1.32
1.72
Information
Accessories
Distribution boxes
Firestop systems
Fixing devices
n x mm
1
2
4
8
12
16
20
32
Support systems
89
ZGGFR-Safety / U-DQ(ZN)BH
FR/LS0H sheath
12 fibres
flame retardant
protective coatings
Features
Fibre-optic safety cable in metal-free central tube design with up to twelve fibres.
The optimum matching of fibre coating and flame-inhibiting stabilizing elements
ensures functional integrity for 30 minutes.
Application
Optical characteristics
The cables are available with different types of Optofil-Safety fibre (see fibre data sheets)
Mechanical
characteristics
temperature range
tensile performance
crush resistance
repeated bending
torsion
bend
water penetration
storage
-25 / +70C
pulling in
-10 / +50C
operation
-25 / +60C
IEC 60794-1-2 E1
IEC 60794-1-2 E3
IEC 60794-1-2 E6
IEC 60794-1-2 E7
IEC 60794-1-2 E11
IEC 60794-1-2 F5
General characteristics
Printing example
Zero halogen,
non corrosive gases
Flame propagation
Flame spread
Smoke density
Circuit integrity
System Circuit integrity
[E30]*
Distribution boxes
Firestop systems
Fixing devices
Support systems
Safety cables
Product information
Accessories
Information
90
glass armouring
IEC 60794-1-2 F1
~ SWISS MADE
ZGGFR-Safety / U-DQ(ZN)BH
Safety cables
Product information
loose tube
cable
max.
max.
mm
kg/km
mm
12
7.8
72
120
1000
ZGGFR-Safety
1x12
500
301 1084
Versions
U-DQ(ZN)BH 1xm
description
numbe
E9/125 G.652.D
G50/125 OM2
G50/125 OM3
G62.5/125 OM1
ZGGFR-Safety
187 288
186 363
190 604
186 638
1x4
1x6
191 867
186 639
191 851
190 792
1x8
on request
190 621
on request
on request
ZGGFR-Safety
1x12
12
190 719
187 293
191 796
187 305
Information
Accessories
Distribution boxes
Firestop systems
ZGGFR-Safety
ZGGFR-Safety
Support systems
no. of fibres
U-DQ(ZN)BH 1xm
Fixing devices
description
91
wbGGFR-Safety / U-DQ(ZN)BH
FR/LS0H sheath
glass armouring
Features
Fibre-optic safety cable in metal-free central tube design with up to twelve fibres.
The optimum matching of fibre coating and flame-inhibiting stabilizing elements
ensures functional integrity for 30 minutes.
Application
Optical characteristics
The cables are available with different types of Optofil-Safety fibre (see fibre data sheets)
Mechanical
characteristics
temperature range
tensile performance
crush resistance
repeated bending
torsion
bend
water penetration
storage
-25 / +70C
pulling in
-10 / +50C
operation
-25 / +60C
IEC 60794-1-2 E1
IEC 60794-1-2 E3
IEC 60794-1-2 E6
IEC 60794-1-2 E7
IEC 60794-1-2 E11
IEC 60794-1-2 F5
General characteristics
Printing example
Distribution boxes
Firestop systems
Fixing devices
Support systems
Safety cables
Product information
Zero halogen,
non corrosive gases
Flame propagation
Flame spread
Smoke density
Circuit integrity
System Circuit integrity
[E30]*
Information
Accessories
92
12 fibres
flame retardant
protective coatings
IEC 60794-1-2 F1
~ SWISS MADE
wbGGFR-Safety / U-DQ(ZN)BH
Safety cables
Product information
loose tube
cable
max.
max.
mm
mm
wbGGFR-Safety
2x12
24
12.5
166
190
6000
500
733 2639
wbGGFR-Safety
3x12
36
12.5
168
190
6000
300
500
733 2639
wbGGFR-Safety
4x12
48
12.5
170
190
6000
300
500
733 2639
wbGGFR-Safety
5x12
60
12.5
166
190
6000
300
500
733 2639
Versions
fibre Article No. Article No. Article No. Article No.
description
number
E9/125 G.652.D
G50/125 OM2
G50/125 OM3
G62.5/125 OM1
wbGGFR-Safety
2 x 12
24
190 223
187 294
187 360
on request
wbGGFR-Safety
3 x 12
36
190 224
on request
on request
on request
wbGGFR-Safety
4 x 12
48
190 225
192 119
191 191
on request
wbGGFR-Safety
5 x 12
60
190 226
on request
190 605
on request
Information
Accessories
Distribution boxes
Firestop systems
U-DQ(ZN)BH nxm
Support systems
no. of fibres
U-DQ(ZN)BH nxm
Fixing devices
description
93
Product information
Application
Cable duct system for exposure to fire from inside to outside, for prevention of fire propagation
on cabling systems in floors and stairwells.
Installation with screw set directly onto multi cable support (Hermann clamp).
Spacing of fixation 600 mm.
Technical Data
Material
Colour
Approvals
Dimensions
Distribution boxes
Firestop systems
Fixing devices
Support systems
Safety cables
HSK I 30/1200
L=
1200 mm
1 Set
1301 159
HSK I 30/600
L=
600 mm
1 Set
1301 160
HSK I 30/400
L=
400 mm
1301 161
HSK I 30/B90
90 right-hand angle
1301 164
HSK I 30/B90
90 left-hand angle
1 Set
HSK I 30/B45
45 right-hand angle
1 Set
45 left-hand angle
1 Set
1301 163
HSK I 30/B45
1301 167
HSK I 30/Cross
1 Set
1301 166
1 Set
1301 157
1 Piece
Accessories
Additional multi cable support (Hermann clamp) for I30 duct (Hermannkanal)
Article No. Type Info PU
Accessories
SHUD
Hermann clamp
10
Information
1 Set
1 Set
1301 162
1300 964
94
pyroplast-S 100 D
15 kg plastic bucket
10 cartridges/310ml
WUM
Support measure
Safety cables
Product information
Effective support measure for vertical installation of pyrofil cables with circuit integrity
in accordance with DIN 4102-12, using the C-shaped rail 2970 SLD.
Meandering cable laying is not necessary if the WUM is used at intervals of up to 3.5 m.
Goods supplied
Note
The WUM E30 and E90 can be used with all pyrofil Keram cable types
(N)HXH/(N)HXCH FE180/E30-E60, (N)HXH/(N)HXCH FE180/E90,
JE-H(St)H FE180/E30-E90 and JE-H(St)HRH FE180/E30-E90.
Function
The WUM protects the clamp of pyrofil safety cables with circuit integrity,
thereby supporting the vertical cabling system in the event of fire.
Installation
The WUM is slipped over the strap clamp that attaches the cable to the C-shaped rail
at intervals of up to 3.5 m. It is attached to the C-shaped rail by means of slide nuts and threaded
rods.Hollow spaces are filled with mineral wool. The cable inlet and back of the WUM
are sealed with pyroplast fire protection filler S 100 SM-K.
width mm
mm
1301 276
300
1301 278
400
1301 277
500
1301 275
300
1301 274
400
1301 273
500
Information
Accessories
Distribution boxes
Firestop systems
Fixing devices
Support systems
Application
95
Fixing devices
Support systems
Safety cables
Product information
Application
Technical Data
Material
Corrosion protection
Approvals
kg/m PU
1300 999
GR 54-100
100
1,29
3m
1301 078
GR 54-150
150
1,53
3m
1301 079
GR 54-200
200
1,77
3m
Firestop systems
Note: For cutting, a bolt cutter with offset cutting has to be used.
Ceiling console, screwless
Corrosion protection: Sendzimir galvanised in accordance with DIN 17162 (zinc coating app. 21).
Other on request
for
kg/piece PU
Distribution boxes
1301 080
GR DKS 150
GR 54-100
0,68
1301 081
GR DKS 200
GR 54-150
0,75
1301 082
GR DKS 300
GR 54-200
0,87
Accessories
Information
96
for
kg/piece PU
1301 083
GR WKS 150
GR 54-100
0,46
1301 084
GR WKS 200
GR 54-150
0,52
1301 085
GR WKS 300
GR 54-200
0,64
Safety cables
Product information
Wire mesh cable tray accessories
Article No. Type Description Info
- 10 pcs KITASSTR
- 2 pcs ED 275
for 90 angles
- 8 pcs KITASSTR
- 2 pcs ED 275
for T-junctions
- 4 pcs KITASSTR
- 6 pcs KITASSTR
- 2 pcs ED 275
set M8x220
1301 097
1301 098
M8x1000
Support systems
Fixing devices
Firestop systems
PU 50 pieces
Distribution boxes
GR VB
attachment
GS 8x1000
accessories
Contents:
100 underlay disks
Accessories
1301 090
97
Cable tray
Safety cables
Product information
Application
Support systems
Technical Data
Material
Nominal size
Steel galavanised
60 x 100 mm, 60 x 200 mm, 60 x 300 mm, 60 x 400 mm
Cable tray
Firestop systems
Fixing devices
RG 60-10S
100 mm
1 piece = 3 m
3800 033
RG 60-20S
200 mm
1 piece = 3 m
3800 129
RG 60-20S 45 angle
200 mm
1 piece
3800 034
RG 60-30S
300 mm
1 piece = 3 m
3800 035
RG 60-40S
400 mm
1 piece = 3 m
60 RGV-BS 60S
60 mm
1 piece
Lateral connector
3800 036
Accessories
Distribution boxes
Bottom connector
3800 038
VB-BS 10S
100 mm
1 piece
3800 039
VB-BS 20S
200 mm
1 piece
3800 044
VB-BS 30S
300 mm
1 piece
3800 045
VB-BS 40S
400 mm
1 piece
M6
100 pieces
Information
98
3800 041
ALS-BS S
1 piece
Cable tray
Safety cables
Product information
Plugs
Article No. Type Nominal size PU
3800 077
M10x10 SD 10/10
M10x10
100 pieces
3800 042
KWMS 010F
100 mm
1 piece
3800 043
KWMS 020F
200 mm
1 piece
3800 047
KWMS 030F
300 mm
1 piece
3800 048
KWMS 040F
400 mm
1 piece
Support systems
Wall consoles
100 mm
1 piece
200 mm
1 piece
3800 051
KUMS 030F
300 mm
1 piece
3800 053
KUMS 040F
400 mm
1 piece
Hangers
KDU 52-03F
300 mm
1 piece
KDU 52-04F
400 mm
1 piece
3800 056
KDU 52-05F
500 mm
1 piece
3800 057
KDU 52-06F
600 mm
1 piece
3800 058
KDU 52-07F
700 mm
1 piece
3800 059
KDU 52-08F
800 mm
1 piece
3800 060
KDU 52-09F
900 mm
1 piece
3800 061
KDU 52-10F
1000 mm
1 piece
Accessories
3800 054
3800 055
Firestop systems
KUMS 010F
KUMS 020F
Distribution boxes
3800 049
3800 050
Fixing devices
M10x21
100 pieces
nut SEM 10
M10
100 pieces
3800 074
M10x20
100 pieces
Information
3800 072
3800 073
99
Single clamp
Type SAS
Fixing distance 600 mm
Safety cables
Product information
Application
For laying single and multiple cables on ceilings or walls. Circuit integrity is achieved for
pyrofil Keram cable types (N)HXH/(N)HXCH FE180/E30-E60, (N)HXH/(N)HXCH FE180/E90,
JE-H(St)H FE180/E30-E90, JE-H(St)HRH FE180/E30-E90.
Information
Accessories
Distribution boxes
Firestop systems
Fixing devices
Support systems
SAS
100 pcs.
1300 017
SAS
100 pcs.
1300 018
SAS
10
10
100 pcs.
1300 019
SAS
12
11
12
100 pcs.
1300 020
SAS
14
13
14
100 pcs.
1300 021
SAS
16
15
16
100 pcs.
1300 022
SAS
18
17
18
100 pcs.
1300 023
SAS
20
19
20
100 pcs.
1300 024
SAS
22
21
22
100 pcs.
1300 025
SAS
24
23
24
100 pcs.
1300 026
SAS
26
25
26
100 pcs.
1300 027
SAS
28
27
28
100 pcs.
1300 028
SAS
30
29
30
100 pcs.
1300 251
SAS
38
new
29
38
25 pcs.
1300 252
SAS
47
new
38
47
20 pcs.
1300 234
SAS
55
new
47
55
20 pcs.
1300 250
SAS
60
new
55
60
20 pcs.
To attach the single clamp, we recommend the use of Datwyler fire protection plugs K6x5 and the Datwyler tool set SMu 6 SM for quick assembly.
Type SAS pre-assembled single clamp with fire protection plugs type K6x5, 30 mm (Fig.2)
1300 956
SAS
- K6x5
100 pcs.
1300 957
SAS
12
K6x5
11
12
100 pcs.
1300 958
SAS
14
K6x5
13
- 14
100 pcs.
1300 959
SAS
16
K6x5
15
- 16
100 pcs.
Required tool set SMu 6 SM. The required SDS1 32 mm drillbit is included in the set.
Type SAS V4A steel grade 1.4571 (simillar to Fig.1) (ask also for stainless steel plugs)
SAS
19
V4A
15
19
50 pcs.
SAS
24
V4A
20
24
50 pcs.
SAS
29
V4A
25
- 29
50 pcs.
SAS
38
V4A
30
- 38
25 pcs.
SAS
47
V4A
39
- 47
20 pcs.
SAS
55
V4A
48
- 55
20 pcs.
SAS
63
V4A
56
- 63
20 pcs.
Please also see our optional installation methods: Installation of cable bundles in clamps, installation in steel armoured conduits, etc.
100
Strap clamp
Application
Safety cables
Product information
For laying several cables independently in parallel on ceilings and walls.
Circuit integrity is achieved for pyrofil Keram cable types (N)HXH/(N)HXCH FE180/E30-E60,
(N)HXH/(N)HXCH FE180/E90, JE-H(St)H FE180/E30-E90, JE-H(St)HRH FE180/E30-E90.
12
100 pcs.
14
100 pcs.
1300 045
16
12
16
100 pcs.
1300 046
18
14
18
100 pcs.
1300 047
22
18
22
100 pcs.
1300 048
26
22
26
100 pcs.
1300 049
30
26
30
100 pcs.
1300 050
34
30
34
100 pcs.
1300 051
38
34
38
100 pcs.
1300 052
42
38
42
100 pcs.
1300 053
46
42
46
100 pcs.
1300 054
50
46
50
50 pcs.
1300 055
54
50
54
50 pcs.
1300 056
58
54
58
50 pcs.
1300 057
64
58
64
50 pcs.
1300 058
70
64
70
50 pcs.
1300 059
76
70
76
50 pcs.
1300 060
82
76
82
50 pcs.
1300 061
90
82
90
50 pcs.
1300 062
100
90
100
25 pcs.
1300 063
110
100
110
25 pcs.
The C-shaped rail 2970/2 SLD is required to fix the strap clamps.
Article No. C-shaped rail
Slit width PU
1300 064
2970/2 SLD
16 mm
For assembly of the C-shaped rail, we recommend fire protection plugs KDM, 30 mm.
Do not exceed the maximum tensile force on the fire protection plugs!
Shaped rails come in 2 m lengths. Other lengths are available on request.
For fast assembly of the shaped rail, we recommend the tool set SWM-SM.
as required
Fixing devices
10
Firestop systems
Distribution boxes
14
Accessories
12
Information
1300 044
Support systems
101
Strap clamp
Safety cables
Product information
Application
For laying several cables independently or in bundles in parallel on ceilings and walls.
Circuit integrity is achieved for pyrofil Keram cable types (N)HXH/(N)HXCH FE180/E30-E60,
(N)HXH/(N)HXCH FE180/E90, JE-H(St)H FE180/E30-E90, JE-H(St)HRH FE180/E30-E90
(800 mm).
Information
Accessories
Distribution boxes
Firestop systems
Fixing devices
Support systems
102
1300 045
16
100 pcs.
1300 065
LW
16
8 13
100 pcs.
1300 047
22
100 pcs.
1300 066
LW
22
13 19
100 pcs.
1300 048
26
100 pcs.
1300 067
LW
26
19 23
100 pcs.
1300 050
34
100 pcs.
1300 068
LW
34
23 31
100 pcs.
1300 051
38
100 pcs.
1300 069
LW
38
31 36
100 pcs.
1300 052
42
100 pcs.
1300 070
LW
42
36 40
100 pcs.
1300 053
46
100 pcs.
1300 071
LW
46
40 43
100 pcs.
1300 054
50
50 pcs.
1300 072
LW
50
43 47
50 pcs.
1300 055
54
50 pcs.
1300 073
LW
54
50 pcs.
47 51
The C-shaped rail 2970/2 SLD is required to fix the strap clamps.
Article No.
Shaped rail
1300 064
2970/2 SLD
Slit width PU
16 mm
as required
For assembly of the C-shaped rail, we recommend fire protection plugs KDM, 30 mm.
Do not exceed the maximum tensile force on the fire protection plugs!
Shaped rails come in 2 m lengths. Other lengths are available on request.
For fast assembly of the shaped rail, we recommend the Datwyler tool set SWM-SM.
Safety cables
Product information
Application
For laying multiple cables on ceilings or walls. Circuit integrity is achieved for pyrofil Keram
cable types (N)HXH/(N)HXCH FE180/E30-E60, (N)HXH/(N)HXCH FE180/E90,
JE-H(St)H FE180/E30-E90, JE-H(St)HRH FE180/E30-E90.
Goods supplied
Support systems
Drill bit and tool set supplied separately. Recommended drill bit SDS1,
recommended tool set SWM-SM 50.
Article No. 1301 240
Stainless steel plugs on request.
Material
Inner dimensions
Outer dimensions
Maximum load
Fixing distance
Hermann clamp
Sendzimir galvanised sheet
app. 110 mm x 75mm x 80mm
app. 125 mm x 95mm x 80mm
6 kg/m or 3 kg/m*
800 mm or 600 mm*
Hermann clamp S
Sendzimir galvanised sheet
app. 70 mm x 52 mm x 56 mm
app. 84 mm x 73 mm x 56 mm
3 kg/m*
800 mm or 600 mm*
Firestop systems
Technical Data
Fixing devices
10 pieces
750 pieces/skeleton box
1301 280
Hermann clamp S
10 pieces
1301 279
Hermann clamp S
1301 240
10 pieces
3800 156
10 pieces
3800 157
10 pieces
Accessories
Hermann clamp
Hermann clamp
Information
1300 964
1300 346
Distribution boxes
103
Firestop systems
Safety cables
Product information
Application
Support systems
Identification sign
pyroplast-S 100 P
301 371
301 370
pyroplast-S 100 SM
soffits
1300 467
1300 478
Identification sign
Set consists of
of a cable bulkhead
10 identification signs
Information
104
in box = 1.5 m2
pyroplast-S 100 D
Accessories
Distribution boxes
Firestop systems
Fixing devices
Firestop systems
Plugs / Accessories
Identification sign
Application
Safety cables
Product information
Used to form a bulkhead for cable wall and ceiling penetration
against the effects of fire for a period of 90 minutes in accordance
with DIN 4102-9 (fire resistance class S90).
BDS
BDS
Support systems
1300 473
BDS
BDS
BDS
BDS
BDS-N (1K)
wall soffits
1300 478
Identification sign
Set consists of 10
of a cable bulkhead
Identification signs
Information
Firestop systems
Distribution boxes
Accessories
1300 472
Fixing devices
105
Product information
Application
For connection of two pyrofil Keram cable types (N)HXH/(N)HXH CL/(N)HXCH FE180/E30-E60,
(N)HXH/(N)HXCH FE180/E90.
The cable joint provides the relevant circuit integrity of the cables.
Goods supplied
Construction
The joint consist of several heat-absorbing inner joints (depending on the number of conductor
connections), an external joint and several insulating tubes that act as a flame barrier.
Assembly
Fixing devices
Support systems
Safety cables
Distribution boxes
Firestop systems
from
1,5 mm2 up to
4 mm2
joint SMH4
1300 311
from
6 mm2 up to
10 mm2
joint SMH4
1300 312
from
16 mm2 up to
25 mm2
joint SMH4
1300 313
from
35 mm2 up to
50 mm2
joint SMH4
1300 314
from
70 mm2 up to
95 mm2
joint SMH4
1300 315
from
120 mm2 up to
150 mm2
joint SMH4
1300 316
from
185 mm2 up to
240 mm2
joint SMH4
1300 317
from
1,5/1,5 mm2 up to
4/4 mm2
joint SMHC4
1300 318
from
6/6 mm2 up to
10/10 mm2
joint SMHC4
1300 319
from
16/16 mm2 up to
25/16 mm2
joint SMHC4
1300 320
from
35/16 mm2 up to
50/25 mm2
joint SMHC4
1300 321
from
70/35 mm2 up to
95/50 mm2
joint SMHC4
Information
Accessories
For Datwyler pyrofil Keram types (N)HXH-O 4-conductor- or NHXH-J 5-conductor cables
1300 322
from
120/70 mm2 up to
150/70 mm2
joint SMHC4
1300 323
from
joint SMHC4
106
Hercules cover
AHD E30-E90
Safety cables
Product information
Application
Terminal box or cover for power current and low current in accordance with DIN 4102-12
to protect commercial distribution, branch boxes and sub-distribution boxes against the effects
of fire for a period of 30 or 90 minutes (circuit integrity class E30 or E90), e.g. emergency lighting,
alarm circuits and fire announcement systems, fire alarm systems, etc.
Goods supplied
Support systems
Hercules distribution box E30-E90 Typ HS... (Power current distribution box)
incl. mounting screws, cartridge of fire protection filler S 100 SM-K
top hat rail 35x7,5x250 mm.
Function
Installation
The time required for assembly of the E30-E90 Hercules distribution box or cover is around 10
minutes. The screws are screwed into a predrilled hole without plugs. The cable inlets and outlets
are sealed with the pyroplast S 100 SM-K fire protection filler. The cables do not not need to be tied.
301 382
301 375
HS 263013 E90
301 376
HS 353013 E90
301 377
HS 523013 E90
1 pc.
35 x 7,5 1-row
1 pc.
35 x 7,5 2-rows
1 pc.
35 x 7,5, 3-rows
1 pc.
Distribution boxes
The Hercules distribution box or cover E30-E90 can be used for all pyrofil Keram cable types
(N)HXH/(N)HXCH FE 180/E30-E60, (N)HXH/(N)HXCH FE 180/E90,
JE-H(ST)H FE180/E30-E90/ JE-H(ST)HRH FE180/E30-E90.
Accessories
Note
Firestop systems
Fixing devices
Hercules distribution box E30-E90 Typ HI... (Low current distribution box)
incl. mounting screws, cartridge of fire protection filler S 100 SM-K
QSA back mount frame ... x 105 x 50 mm.
(Quante: depth 30 mm, pitch: 27,5 mm)
301 378
HI 263013 E90
1 pc.
301 379
HI 353013 E90
1 pc.
301 380
HI 523013 E90
1 pc.
Information
107
Product information
Application
Goods supplied
Halogen-free plastic box, cable glands, ceramic clamps, mounting rail and fire protection plugs.
Technical Data
Material
Colour
Protection class
Accessories
Technical Data
Accessories
Distribution boxes
Firestop systems
Fixing devices
Support systems
Safety cables
100 x 100 x 50
5 x 0,5-6 mm
301 373
100 x 100 x 50
3 x 1,5-10 mm2
301 381
165 x 165 x 76
8 x 0,5-6 mm2
for branches up to PU
1,5 mm2
1 pc.
4 mm2
1 pc.
1,5 mm2
1 pc.
Accessories
Information
LxWxH
660 301
40 x 20 x 20
108
AC 230V-Fuseholder 5 x 20 mm
1 pc.
AD E30
Application
Goods supplied
Technical Data
Material
Systems test
Wiring assembly
Cable inlets
Colour
Protection class
Support systems
Safety cables
Product information
2.5 - 6 mm2
1 pc.
AD E30
2.5 - 6 mm2
1 pc.
on request
AD E30
2.5 - 6 mm2
1 pc.
on request
AD E30
2.5 - 6 mm2
1 pc.
Information
on request
on request
Accessories
Distribution boxes
Firestop systems
Fixing devices
109
Emergency lighting
Product information
Application
Technical Data
Goods supplied
Installation
Surface or flush-mounting
(WxHxD) mm
on request
BNL / surface
1 pc
on request
BNL / flush-mounting
1 pc
Accessories
Distribution boxes
Firestop systems
Fixing devices
Support systems
Safety cables
BNL
Emergency lighting/
escape route signage
Information
110
E0 multi-cable support
Application
Safety cables
Product information
For fire-safe installation of multiple cables or lines along ceilings or walls above fireproof ceilings in
accordance with MLAR 11/2005 (not for functional integrity!).
Excerpt from MLAR 11/2005 3.5.3.:
The special requirements pertaining to fireproof fasteners for lines installed in the area
between floor slabs and suspended ceilings must be observed.
Set consists of multi cable supports E0 and fire protection plugs KDM, 30 mm.
Material
Inner dimensions
Outer dimensions
Cable load
Installation spacing
Cable weight
E0S
approx 55 x 35 x 33 mm
approx 63 x 45 x 33 mm
30 40
6,0 4,5
50 60
3,6 3,0
70
2,6
80 cm
2,3 kg/m
E0 multi-cable support
Article No. Type Inner dimensions (mm) Outer dimensions (mm) PU
3 800 086
E0 multi-cable support
approx 80 x 45 x 33
approx 87 x 60 x 33
25 pcs.
3 800 087
E0 S multi-cable support
approx 55 x 35 x 33
approx 63 x 45 x 33
50 pcs.
Accessories
Distribution boxes
Firestop systems
Technical Data
Support systems
Fixing devices
Goods supplied
Information
To speed up installation times for the E0 multi-cable support, we recommend using the Datwyler SWM-SM 50 setting tool.
111
Firestop systems
Fixing devices
Support systems
Safety cables
K 6x5
30mm seat depth
KDM
30mm seat depth
Product information
Application
Note
30 mm
Single/distance clamps
with M6 thread
1300 954
Single/distance clamps
30 mm
Hermann clamp
1300 954
Shaped rails
30 mm
2970/2 SLD
1300 005
Plugs KMuF10
Distribution boxes
Contains 50 KMuF10.
Required drill bit: SDS Duo-Set hv60
1300 006
Contains 50 KMuF12.
Plugs KMuF12
301 369
Plugs K6x80
thickness up to 75mm
1300 448
Plugs K6x105
thickness up to 105mm
1301 094
Information
Accessories
Set/Info
112
tread rod M8
1.
2.
3.
SDS Duo-Set
consisting of:
SDS Duo Adapter hv60
3x Duo tapered drill bit 6mm
3. 1x knock-out wedge
1.
SWM-SM
SWS-SM 50
SMu 6 SM
SDS 1 32 mm
SDS 2 42 mm
2.
Safety cables
Product information
The special drill bit enables holes to be drilled to the required depth.
Advantages
Ensures required
- hole depth
- less working time
- less drilling
- longer lasting drill bits
SDS1
1300 007
SDS 2
1300 009
1300 013
SMu10H
1300 014
SMu12H
1300 963
SMu 6 SM
1300 860
SWM-SM 50
Information
Accessories
1300 961
Firestop systems
1300 962
Distribution boxes
Fixing devices
Support systems
Application
113
Safety cables
MMS-P 7,5/45
40mm seat depth
MMS-St 6/60
40mm seat depth
HMS 5/40
30mm seat depth
Identification sign
Product information
Application
Note
The mounting screws are suitable for applications in lime-sand bricks and aerated lime-sand bricks,
red bricks and concrete.
Support systems
The gas concrete plugs are suitable for gas concrete P3,3 or better.
1301 218
HMS 5/40
Simple/distancing clamps
with M6 thread
Fixing devices
3800 097
HMS-St 6/60
Simple/distancing clamps
with M6 thread
1300 461
MMS-P 7.5/45
Distribution boxes
Firestop systems
Accessories
is needed
Shaped rails
2970/2 SLD
Hermann clamps
1300 479
Identification sign
Cable system
of a cable system
signs
Article No.
1301 301
PBD M 6x10
Simple/distancing clamps
Shaped rails
Hermann clamps
Cable trays
1301 306
PBD M 10x10
1301 313
EWP 6x10
Driven by hammer
1301 302
Information
1301 314
EWP 10x10
Driven by hammer
1301 307
114
Safety cables
Product information
Support systems
Halogen-free smooth plastic tube with molded sleeve on one end, in lengths of 3m.
Article No. Tube type Inner [mm] Outer [mm] PU
1300 600
Kupa DN 16
13,0
16,0
111 m
0,545
1300 601
Kupa DN 20
16,8
20,0
111 m
0,817
1300 602
Kupa DN 25
21,5
25,0
57 m
1,090
1300 603
Kupa DN 32
28,0
32,0
57 m
1,393
1300 604
Kupa DN 40
35,5
40,0
21 m
2,024
1300 605
Kupa DN 50
45,2
50,0
21 m
2,802
1300 606
Kupa DN 63
57,8
63,0
21 m
3,542
Information
Fixing devices
Material
Colour
Approvals
Classification
Firestop systems
Technical Data
Distribution boxes
Accessories
Application
115
Safety cables
Product information
Information
Accessories
Distribution boxes
Firestop systems
Fixing devices
Support systems
116
Article No.
Sleeve PU
1300 607
Kupa DN 16
MM
25 pcs.
1300 608
Kupa DN 20
MM
50 pcs.
1300 609
Kupa DN 25
MM
50 pcs.
1300 610
Kupa DN 32
MM
25 pcs.
1300 611
Kupa DN 40
MM
25 pcs.
1300 612
Kupa DN 50
MM
10 pcs.
1300 613
Kupa DN 63
MM
5 pcs.
Kupa DN 16
MB
25 pcs.
1300 615
Kupa DN 20
MB
25 pcs.
1300 616
Kupa DN 25
MB
25 pcs.
1300 617
Kupa DN 32
MB
25 pcs.
1300 618
Kupa DN 40
MB
25 pcs.
1300 619
Kupa DN 50
MB
10 pcs.
1300 620
Kupa DN 63
MB
5 pcs.
SAS 16
DN 16
1300 023
SAS 20
DN 20
100 pcs.
100 pcs.
1300 026
SAS 26
DN 25
100 pcs.
1300 051
SAS 38
DN 32
25 pcs.
1300 252
SAS 47
D new
DN 40
20 pcs.
1300 234
SAS 55
D new
DN 50
20 pcs.
In order to attach Kupa plastic armoured conduits, we recommend SAS single clamps with fire protection plugs K6x5, 30mm,
or strap clamps type B with C-shaped rail SLD and fire protection plugs KDM 30mm.
Please also see our optional installation methods:
Installation of cable bundles in clamps, installation in steel armoured conduits, etc.
Safety cables
Product information
Application
Technical Data
Material
Colour
Approvals
Classification
Support systems
1300 621
Stapa DN 16 SV
13,3
16,0
30 m
1300 622
Stapa DN 20 SV
17,3
20,0
30 m
1300 623
Stapa DN 25 SV
22,1
25,0
30 m
1300 624
Stapa DN 32 SV
29,0
32,0
21 m
3800 135
Stapa DN 40 SV
37,0
40,0
15 m
1300 626
Stapa DN 50 SV
47,0
50,0
15 m
1300 627
Stapa DN 63 SV
59,5
63,0
15 m
Firestop systems
Fixing devices
25 pcs.
Stapa DN 20 SVM
50 pcs.
1300 641
Stapa DN 25 SVM
50 pcs.
1300 642
Stapa DN 32 SVM
50 pcs.
1300 643
Stapa DN 40 SVM
25 pcs.
1300 644
Stapa DN 50 SVM
10 pcs.
1300 645
Stapa DN 63 SVM
5 pcs.
Accessories
Stapa DN 16 SVM
1300 640
Information
1300 639
Distribution boxes
117
Safety cables
Product information
Insertable 90 bend, galvanised
Support systems
Stapa DN 16 SVB
15 pcs.
1300 649
Stapa DN 20 SVB
25 pcs.
1300 650
Stapa DN 25 SVB
25 pcs.
1300 651
Stapa DN 32 SVB
20 pcs.
15 pcs.
1300 652
Stapa DN 40 SVB
1300 653
Stapa DN 50 SVB
5 pcs.
1300 654
Stapa DN 63 SVB
3 pcs.
Information
Accessories
Distribution boxes
Firestop systems
Fixing devices
118
1300 684
Stapa DN 16 SVE
25 pcs.
1300 630
Stapa DN 16 SKE
50 pcs.
1300 685
Stapa DN 20 SVE
50 pcs.
1300 631
Stapa DN 20 SKE
100 pcs.
1300 686
Stapa DN 25 SVE
50 pcs.
1300 632
Stapa DN 25 SKE
100 pcs.
1300 687
Stapa DN 32 SVE
50 pcs.
1300 633
Stapa DN 32 SKE
50 pcs.
1300 688
Stapa DN 40 SVE
25 pcs.
1300 634
Stapa DN 40 SKE
50 pcs.
1300 689
Stapa DN 50 SVE
10 pcs.
1300 635
Stapa DN 50 SKE
25 pcs.
1300 690
Stapa DN 63 SVE
5 pcs.
1300 636
Stapa DN 63 SKE
20 pcs.
1300 021
SAS
16
DN 16
1300 023
SAS
20
DN 20
100 pcs.
1300 026
SAS
26
DN 25
100 pcs.
1300 051
SAS
38
DN 32
25 pcs.
1300 252
SAS
47
D new
DN 40
20 pcs.
1300 234
SAS
55
D new
DN 50
20 pcs.
In order to attach Stapa steel armoured tubes, we recommend SAS single clamps with fire protection plugs K6x5, 30mm,
or strap clamps type B with C-shaped rail SLD and fire protection plugs KDM 30mm.
Please also see our optional installation methods:
Installation of cable bundles in clamps, installation in plastic armoured conduits, etc.
100 pcs.
Safety cables
Product information
Application
For laying single and multiple cables on ceilings or walls. Circuit integrity E30 is achieved for
pyrofil-Keram cable types (N)HXH/(N)HXH CL/ FE180/E30-E60, JE-H(St)H FE180/E30-E90
and JE-H(St)HRH FE 180/E30-E90.
Maximum permissible fixing distance: 800mm.
Technical Data
Material
Colour
Approvals
Classification
Support systems
Fixing devices
Stapa DN 16 SL 13,3
16,0
30 m
1300658
Stapa DN 20 SL 17,3
20,0
30 m
1300659
Stapa DN 25 SL 22,1
25,0
30 m
1300660
Stapa DN 32 SL 29,0
32,0
21 m
1300661
Stapa DN 40 SL 37,0
40,0
15 m
1300662
Stapa DN 50 SL 47,0
50,0
15 m
1300663
Stapa DN 63 SL 59,9
63,0
15 m
Firestop systems
Stapa DN 20 SLM
50 pcs.
1300 668
Stapa DN 25 SLM
50 pcs.
1300 669
Stapa DN 32 SLM
50 pcs.
1300 670
Stapa DN 40 SLM
25 pcs.
1300 671
Stapa DN 50 SLM
10 pcs.
1300 672
Stapa DN 63 SLM
5 pcs.
In order to attach Datwyler Stapa steel armoured conduits, we recommend SAS single clamps
with fire protection plugs K6x5, 30mm, or strap clamps type B with C-shaped rail SLD and
fire protection plugs KDM 30mm.
Accessories
Stapa DN 16 SLM
1300 667
Information
1300 666
Distribution boxes
119
Safety cables
Product information
Insertable 90 bend, black varnished
Support systems
Stapa DN 16 SLB
15 pcs.
1300 676
Stapa DN 20 SLB
25 pcs.
1300 677
Stapa DN 25 SLB
25 pcs.
1300 678
Stapa DN 32 SLB
20 pcs.
15 pcs.
1300 679
Stapa DN 40 SLB
1300 680
Stapa DN 50 SLB
5 pcs.
1300 681
Stapa DN 63 SLB
3 pcs.
Firestop systems
Fixing devices
Stapa DN 16 SLE
25 pcs.
1300 630
Stapa DN 16 SKE
50 pcs.
1300 694
Stapa DN 20 SLE
50 pcs.
1300 631
Stapa DN 20 SKE
100 pcs.
1300 695
Stapa DN 25 SLE
50 pcs.
1300 632
Stapa DN 25 SKE
100 pcs.
1300 696
Stapa DN 32 SLE
50 pcs.
1300 633
Stapa DN 32 SKE
50 pcs.
1300 697
Stapa DN 40 SLE
25 pcs.
1300 634
Stapa DN 40 SKE
50 pcs.
1300 698
Stapa DN 50 SLE
10 pcs.
1300 635
Stapa DN 50 SKE
25 pcs.
1300 699
Stapa DN 63 SLE
5 pcs.
1300 636
Stapa DN 63 SKE
20 pcs.
Information
Accessories
Distribution boxes
120
1300 021
SAS
16
DN 16
1300 023
SAS
20
DN 20
100 pcs.
100 pcs.
1300 026
SAS
26
DN 25
100 pcs.
1300 051
SAS
38
DN 32
25 pcs.
1300 252
SAS
47
D new
DN 40
20 pcs.
1300 234
SAS
55
D new
DN 50
20 pcs.
In order to attach Datwyler Stapa steel armoured tubes, we recommend SAS single clamps with fire protection plugs K6x5, 30mm,
or strap clamps type B with C-shaped rail SLD and fire protection plugs KDM 30mm.
Please also see our optional installation methods:
Installation of cable bundles in clamps, installation in plastic armoured conduits, etc.
Core colours in accordance with DIN VDE 0293 - 308 : 01/2003 (CENELEC HD 308 10/2001)
No. of cores
1(-O)
Function of core
1(-J) 2(-O) 2(-J) 3(-O) 3(-J ) 3a(-O) 4(-O) 4(-J ) 4a(-J) 5(-O) 5(-J)
PE
LN
LPE
3L
LNPE
2LN
3LN
3LPE
2LNPE
4LN
3LNPE
Yellow-green (PE)
Blue (N)
Brown (L)
Black (L)
Grey (L)
Colour code for cables 6 cores
Phase conductor
= Black with white number printing
Protective conductor = Green-yellow
L = Phase conductor
N = Neutral conductor
PE = Protective conductor
Safety cables
Cable printing
In order to guarantee the retraceability, all pyrofil cables are identified with the production batch.
The meter marking simplyfies the cable handling.
Printing example
DATWYLER PYROFIL KERAM FE180 N x MM2 SWISS MADE PRODUCTION BATCH METER MARKS
Core colours in accordance with VDE 0815 for fire alarm cables JE-H(ST)H...Bd
1. Two pairs
2. Three pairs and more
Pair 1: a-core blue, b-core red Pair 1: a-core blue, b-core red
Pair 2: a-core grey, b-core yellow Pair 2: a-core grey, b-core yellow
Remark: Only two pair cable is a Quad Pair 3: a-core green, b-core brown
Pair 4: a-core white, b-core black
Core a
Core b
1
2
3
4
Support systems
Ring group 1
Ring group 2
Ring group 3
Ring group 4
Fixing devices
Pair
1 2 3 4 5 6 7 8 9 10
11 12
13 14 15 16
17 18 19 20
4 cores
II
II
8 cores resp.
4 pair
II
III
IV
II
III
IV
II
III
IV
II
III
IV
II
III
IV
Distribution boxes
Ring group
consist. of
Ring colour
Helix
Core colours of wiring cables J-H(ST)H...Bd
Basic colours of insulation of the 5 star quads of a bundle
1. Quad: Basic colour of all cores red
4. Quad:
2. Quad: Basic colour of all cores green
5. Quad:
3. Quad: Basic colour of all cores grey
Accessories
Bundle no.
Firestop systems
Identification of bundles
Circuit 1
Circuit 2
a-Core
b-Core
a-Core
b-Core
Information
121
300 mm
Safety cables
600 mm
Standard laying technics with strap clamp with trough (of different manufacturers)
600 / 800 mm
bundling e.g. 30 cables 3x1,5mm2
Firestop systems
Fixing devices
Support systems
Hermann clamp:
1200 mm
Information
Accessories
Distribution boxes
122
30Kg
1500 mm
EN European Norm
Support systems
Accessories
Distribution boxes
Firestop systems
EN 50200
EN 50267-1
Information
Method of test for resistance to fire of unprotected small cables for use in emergency circuits
Common test methods for cables under fire conditions. Tests on gases evolved during combustion
of materials from cables. Apparatus
EN 50267-2-1
Common test methods for cables under fire conditions. Tests on gases evolved during combustion
of materials from cables. Procedures. Determination of the amount of halogen acid gas
EN 50267-2-2
Common Test Methods for Cables Under Fire Conditions - Tests on Gases Evolved During Combustion
of Materials From Cables - Part 2-2: Procedures - Determination of Degree of Acidity of Gases for Materials
by Measuring pH and Conductivity
EN 50267-2-3
Common test methods for cables under fire conditions. Tests on gases evolved during combustion of materials
from cables. Procedures. Determination of degree of acidity of gases for cables by determination of the weighted
average of pH and conductivity
EN 50362
Method of test for resistance to fire of larger unprotected power and control cables for use in emergency circuits
EN 50363-5
Insulating, sheathing and covering materials for low voltage energy cables - Part 5: Halogen-free, cross-linked
insulating compounds
EN 60228
Conductors of insulated cables
EN 60332-1-1 Tests on electric and optical fibre cables under fire conditions - Part 1-1: Test for vertical flame propagation
for a single insulated wire or cable - Apparatus
EN 60332-1-2 Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation
for a single insulated wire or cable - Procedure for 1kW pre-mixed flame
EN 61034-1
Measurement of smoke density of cables burning under defined conditions. Test apparatus
EN 61034-2
Measurement of smoke density of cables burning under defined conditions. Test procedure and requirements
Fixing devices
IEC 60228
Conductors of insulated cables
IEC 60331-1 Tests for electric cables under fire conditions - Circuit integrity - Part 1: Test method for fire with shock at a
temperature of at least 830 C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall
diameter exceeding 20 mm
IEC 60331-11 Tests for electric cables under fire conditions - Circuit integrity - Part 11: Apparatus - Fire alone at a flame
temperature of at least 750 C
IEC 60331-2 Tests for electric cables under fire conditions - Circuit integrity - Part 2: Test method for fire with shock at a
temperature of at least 830 C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall
diameter not exceeding 20 mm
IEC 60331-21 Tests for electric cables under fire conditions - Circuit integrity - Part 21: Procedures and requirements Cables of rated voltage up to and including 0,6/1,0 kV
IEC 60331-23 Tests for electric cables under fire conditions - Circuit integrity - Part 23: Procedures and requirements Electric data cables
IEC 60331-25 Tests for electric cables under fire conditions - Circuit integrity - Part 25: Procedures and requirements Optical fibre cables
IEC 60332-1-1 Test on electric and optical fibre cables under fire conditions. Part 1-1
Test for vertical flame propagation for a single insulated wire or cable - Apparatus
IEC 60332-1-2 Test on electric and optical fibre cables under fire conditions. Part 1-2
Test for vertical flame propagation for a single insulated wire or cable Procedure for 1 kW pre-mixed flame
IEC 60332-3-10 Tests on electric cables under fire conditions - Part 3-10: Test for vertical flame spread of vertically-mounted
bunched wires or cables - Apparatus
IEC 60332-3-22 Tests on electric and optical fibre cables under fire conditions Part 3-22: Test for vertical flame spread
of vertically-mounted bunched wires or cables Category A
IEC 60332-3-23 Tests on electric and optical fibre cables under fire conditions - Part 3-23: Test for vertical flame spread
of vertically-mounted bunched wires or cables - Category B
IEC 60332-3-24 Tests on electric and optical fibre cables under fire conditions - Part 3-24: Test for vertical flame spread
of vertically-mounted bunched wires or cables - Category C
IEC 60332-3-25 Tests on electric and optical fibre cables under fire conditions - Part 3-25: Test for vertical flame spread
of vertically-mounted bunched wires or cables - Category D
IEC 60754-1 Test on gases evolved during combustion of materials from cables - Part 1: Determination of the amount
of halogen acid gas
IEC 60754-2 Test on gases evolved during combustion of electric cables - Part 2: Determination of degree of acidity of
gases evolved during the combustion of materials taken from electric cables by measuring pH and conductivity
IEC 60794-1-2
Optical fibre cables - Part 1-2: Generic specification - Basic optical cable test procedures
IEC 61034-1
Measurement of smoke density of cables burning under defined conditions - Part 1: Test apparatus
IEC 61034-2
Measurement of smoke density of cables burning under defined conditions - Part 2: Test procedure
and requirements
Safety cables
123
Safety cables
Fire behaviour of building materials and building components- Part12: Circuit integrity maintenance of
electric cable systems; requirements and testing
Fixing devices
Support systems
BS British Standard
BS 5839-1+A2
Fire detection and fire alarm systems for buildings. Code of practice for system design, installation,
commissioning and maintenance
BS 6387
Specification for performance requirements for cables required to maintain circuit integrity under fire conditions
BS 7629-1
Electric cables. Specification for 300/500 V fire resistant screened cables having low emission of smoke
and corrosive gases when affected by fire. Multicore and multipair cables
BS 7655-0
Specification for insulating and sheathing materials for cables. General introduction
BS EN 60228
Conductors of insulated cables
BS 8434-2 +A2 Test for unprotected small cable for use in emergency circuits BS EN 50200 with a 930C flame and
with water spray
Firestop systems
E90 Kabel fr Wasser-Lschanlagen mit zustzlichem Funktionserhalt bei Einwirkung von Wasser,
Anforderungen und Prfmethoden (Entwurf )
NBN 713-020
Fire fighting - Fire performance of building materials and products - Fire resistance of building materials
Information
Accessories
Distribution boxes
124
capacity
bu
asset
m a n a ge
m en
urce
reso
m e nt
nag e
technology, ne
tw
,
ing
ork
ild
e
man nerg
age y
me
ma
m a n a ge m e nt
nt
ture
ruc ent
t
s
m
ra
nf age
an
documentation
&
visualisation
planning
&
controlling
analysing
&
managing
process
workflow generation
budgeting
work orders
troubleshooting
escalation management
resource optimisation
analysis,
reports, queries
active risk
management
remote monitoring
remote controlling
service and
maintenance automisation
Panorama
Management Software Solution
Support of universal building, technology
and network management
Datwyler
125
Panorama
Customised solutions
Optimal planning by
comprehensive function modules
Panorama
a Datwyler solution
Planning by
workflows
functions
Infrastructure
mapping
complete documentation
of all recorded objects
infrastructure visualisation
and management
set-up of processes
by ITIL
coordination
of resources
Sites
graphic and alphanumerical site
management
visualisation of imported CAD, GIS
and Google Earth data
area management information such
as utilisation, energy consumption
and cost data
calculation and evaluation of site data
126
Datwyler
Buildings
technical and commercial building
management
visualisation of imported CAD, GIS
and Google Earth data
facility management information
such as heating systems, cabling
infrastructures, climate and access
control
calculation of lease/additional costs
visualisation of consumption data
maintenance and service management
by processes and workflows
control centre
resources
processes
networks
technologies
buildings
sites
cockpit
objects
assignment of
activities/tasks
Panorama
Customised solutions
Technologies
facilities and devices visualisation
and documentation
device/array layout, configuration
and operation via remote monitoring
and remote control
reports support fault management, deficiency analysis and asset
management
Resources
coordination of staff, tools, equipment, machinery
planning of maintenance and service
activities
free definition of resources and
intervals
Control centre
control centre function for building
control, transportation and energy
systems, production lines and further
applications
remote monitoring and remote control enable control of heterogeneous
technologies
visualisation and monitoring of technical processes (Supervisory
Control and Data Acquisition, SCADA)
Networks
management and visualisation, from
cable trays up to single optical fibre
illustration of infrastructure including
all logical connections
workflow and task instructions for
patch panel moves, adds, changes
Fault management
and alarm systems
incoming alarms ordered
by priorities
individually defined workflows enable to send emails, to create pop-up
screens and to start assignments of
tasks and processes
Processes, workflows
processes and workflows for layout,
installation and roll-out: support of
maintenance and service intervals,
fault and alarm management, IT
Infrastructure Library (ITIL), et cetera
Development of individual
solutions for technical and
commercial building management
Some examples are:
collection of metering data
connection to facility management system
benchmarking
calculation and billing
Datwyler services
User requirement
specifications
Design
technical
specifications
statement
of work
interface
definitions
Statement
of work
Implementation
software
adaptation
interface
adjustment
system check
Acceptance
procedure
Roll-Out
roll-out to user
Going live
training, documentation
user support, maintenance, hosting
Datwyler
127
System solutions
from a single source
ICT Networks
Leading know-how
As a provider of total solutions for information and telecommunication networks,
Datwyler possesses extensive know-how accumulated over decades:
- Almost 100 years of experience in cable production.
- Leading material, production and process know-how in the fabrication of copper
and fibre-optic cables and components.
- Solid electro-technical competency.
- Close collaboration with renowned technical universities, international standards
committees, and independent testing institutes.
- Broad systems competence.
Diverse applications
In the field of ICT networks Datwyler concentrates on communication infrastructures
for public and commercial buildings and for FTTx networks.
Some examples are:
-
-
-
-
-
-
In these market segments we can also flexibly meet individual customer requirements
up to and including turnkey and multi-site projects with our cost-effective, modular
system solutions and compehensive services.
128
Datwyler
Cologne
Dubai
Zollikofen
Zurich
Munich
Berlin
Datwyler
129
Product Overview
Patch cords
PS-TERATM/RJ45
Patch panel
MPS 12x, 16x, 24x, 32x
for MS 1/8 or PS-TERATM
modules
Module
Faceplate
for PS-TERATM module PS-TERATM 1/8 Cat.7
Faceplate
for MS-K Plus 1/8
modules
RJ45 module
MS-K Plus 1/8 Cat.6A
Industrial
data outlet IP67
for MS 1/8 module
Industrial
REG adapter MS IP20
for MS 1/8 module
Industrial
patch cord PUR
Copper
patch cord
Data outlets
CSD Plus 2/8 K,
CSD Plus 2/8 U
Cat.6A (IEC)
Patch panel
CSA 24/8 Plus Cat. 6A
130
Datwyler
FO patch panel
OV-A
FO data outlet
FO patch panel
FO wall-mounted
distribution box
OV-W
FO indoor cable
uninet installation/
flexible cable
e.g.:
Cat.6A: 7060 4P
Cat.7: 7080 4P
better than Cat.7A:
7150 4P
Multimedia
TV balun, active balun up to
862 MHz for the distribution of
CATV signals
Multimedia
TV panel, active distributor field up to
862 MHz for the distribution of CATV signals
Datwyler
131
Product Overview
Copper
Fibre optic
Cables
Connection
Cables
Connection
uninet installation/
flexible cable
Modules
Patch panels
Faceplates
Multiple cable
pre-assembled copper data cables
Floor-box solutions
Measurement cable
Accessories
Fibre optic
multiple cable
BreakOut system
Accessories
screened / unscreened
screened / unscreened
Are you looking for a building, technology and network management software which enables effective planning, management, documentation
and control of all objects and processes around your infrastructure? Feel free to ask for details about Panorama!
132
Datwyler
High Density
Wireless
Active
MHD
Network/Server racks
Wi-Fi
Multimedia and
switching
MHD housings
Network rack
Wi-Fi Arrays
TV panel
active distributor field up to 862 MHz
for the distribution of CATV signals
Server rack
Transformers
TV balun
active balun up to 862 MHz
for the distribution of CATV signals
Wall chassis
Access points
Network cameras
Management system
Accessories
Switches
Minirack
Accessories
Find our ICT network products and solutions in the respective catalogue.
www.datwyler.com
Datwyler
133
Maximum flexibility
in installation
Building Automation
The modular product portfolio
for optimised system integration
System ECO-A
flatform cable system
System ECO-B
System ECO-C
System ECO-D
System ECO-E
System ECO-F
products for flexible,
efficient integration
System ECO-M
products for
Smart Metering
System ECO-S
software
System ECO-T
134
Datwyler
Leading know-how
As a provider of total solutions for the electrical and communications infrastructure of public and commercial buildings, Datwyler possesses leading know-how acquired over
decades. Applying our competence in materials, production
and processing in the fabrication of flatform cables, we have
developed the ECO-A system, a comprehensive solution
combining flexible power distribution with control and automation of all building functions.
Complete system solutions
Decentral, modular and pluggable Datwyler offers sustainable system solutions tailored to changing customer needs,
upcoming technologies and energy-efficient operation.
Thus, our building automation solutions ensure high operational reliability and low operational costs.
Diverse applications
In recent years Datwyler has extended its proven ECO-A portfolio to include eight product groups for building automation
based on the KNX standard. These product groups are used
in system solutions for basic infrastructure as well as tenant
improvements, including a wealth of applications such as
responsive lighting, intelligent shading, HVAC, connections
to third party systems, visualisation, power data metering
and door communication via SIP. The product groups have
a modular structure and can be deployed in any combination. This makes it possible to achieve a cost-effective solution
for every project. Combined with our flatform cable systems for power distribution and data transmission and with
our control and visualisation software which makes various
systems available on one platform, the Datwyler product
portfolio meets all requirements of intelligent building
automation.
Stuttgart
Frankfurt
Berlin
Datwyler
135
Product Overview
System description
Modern building services installation calls for control and automation of the widest possible range of functions. Whereas
conventional electrical building services installation merely distributes power and could be switched if necessary, the ECO-A
system meets the higher standards demanded of modern building services.
Compared with conventional electrical installation, modern
building management using a Datwyler buildung automation
system features a minimum of cable expenditure, rapid adaptability, and flexible use of space. This guarantees that your investment will retain its value for decades to come.
Our cabling solutions enables the problem-free linking of a very
wide variety of building services functions and facilities that
have been strictly separated to date such as heating, air conditioning, ventilation, lighting, building surveillance, and load
management. Open and closed-loop control operations can be
centralised or decentralised.
The flatform cables and appropriate pre-assembled plug-in and
screw components make insulation stripping unnecessary and
considerably reduce installation time. The installations can be
modified or extended without any major planning effort.
The modular building automation product portfolio enables
optimised system integration. The portfolio ranges from preconfigured plug-and-play solutions for decentralised systems,
to cost-effective semi-centralised room solutions e.g. for
hotels, hospitals and office buildings to total solutions for
centralised building automation systems.
System
ECO-C
products for
the central,
clear integration
System ECO-E
products for simple,
economic integration
136
Datwyler
Power I Adapter
power in- and output
Flatform cable Power I 7x2,5+5x16mm2
for damp location, flatform power cable system for
engine rooms and industrial applications
System ECO-D
compact, plug-in KNX actuators with fast
connection technology for error-free assembly in
intermediate floors or suspended ceilings
System ECO-B
products for the
decentral, modular
integration
KNX IR
Remote Control
ECO-E ZN1IR
Datwyler
137
CablE
Output
Combi Adapter-S
5x Energy+Bus
PVC
5x2,5 mm2 + 2x1,5 mm2
Art.No.1300 235
FR/LSOH
5x2,5 mm2 + 2x1,5 mm2
Art.No.187 028
Art.No.187 034
Combi Adapter
3x Energy+Bus EIB/KNX
Art.No. 1300 282
Combi Adapter-S
5x Energy
Combi Adapter
3x Energy+Bus
Art.No. 1300 282
Combi Adapter-S
Bus
Combi Adapter
3x Energy
FR/LSOH
2x1,5 mm2
Data Adapter
EIB/KNX
Art.No. 1300 286
Data Adapter
Art.No. 1300 353
Power Adapter-S
5x Energy
Power Adapter
3x Energy
Power Adapter
5x Energy
FR/LSOH
5x2,5 mm2
Power 10 Adapter
5x Energy
Power Adapter
5x Energy
FR/LSOH
5x2,5 mm2
FR/LSOH
7x2,5 mm2
9-16
13-18
11-20,5
FR/LSOH
5x16 mm2
Art.No.187 025
138
Datwyler
9-16
13-18
11-20,5
20-26
Fixing device
Combi Adapter EIB/KNX
5x Energy+Bus EIB/KNX
Art.No. 1300 284
Combi Adapter
5x Energy+Bus
Art.No. 1300 351
Accessories
Uni Fix
Tape
Fix
Combi Tool
stripping tool
Combi Adapter
5x Energy
ending device
Combi End
Uni Fix
Combi Tool
stripping tool
Data End
Fix
Uni Fix
Tape
Fix
Combi Tool
stripping tool
Power Fix
Tape
Power End
Power 10 End
Power 10 Tool
cable stripper
Art.No. 1300 306
Power I Adapter
socket 7x2,5
Art.No. 1301 326
Fix
Tape
Fix
Tape
Power I Adapter
7x2,5 InOut
Art.No.1301 325
Power I Adapter
screw-tightened connection
5x16 Out for single and double branch
connection up to 5x6mm2
Art.No.1301 315
Power I Adapter
screw-tightened connection
5x16 InOut
Art.No.1301 316
Datwyler
139
Building Automation
Mounting
and installation
decentralised mounting
project-specific
configuration
modular devices
plug-in connections
System
ECO-B
System
ECO-C
System
ECO-D
decentralised mounting
Switching Actuator 4 x 16 A
Switching Actuator 6 x 16 A
Switching/
2-fold
Dimming Actuator
2-fold
Blind Actuator
1 x Switch
Combi Actuator
+ 2 x Blinds
56-fold
EnOcean Gateway
+ 4 x 16 A
flat size
plug-in connections
directly to the
Combi cable
centralised mounting
decentralised mounting
flush- or wall-mounting
devices
optional products
and accessories
140
Datwyler
EnOcean Aerial
EnOcean Aerial
System
ECO-E
System
ECO-F
System
ECO-M
System
ECO-T
Products for
Smart Metering
Products for
IP door communication
High-quality user interfaces with touchsensitive tactile zones and multitouch function.
Standard push buttons sensors and
EnOcean Wireless sensors.
Multi-functional Actuator 6 x 10 A
Multi-functional Actuator 4 x 16 A
IR Remote Control
Find our Building Automation products and solutions in the respective catalogue.
Datwyler
141
142
Datwyler
Bonn
Mexiko City
Portsmouth
Diverse applications
Datwyler elevator cable systems meet every requirement for
electrical connections to the elevator cabin. Aside from power
cables, high-quality data cables are being increasingly requested. Integral fibre optic cable can easily handle large volumes
of data. These modern system solutions connect the elevator
cabin to the controls and to the local data network so passengers can enjoy television and video services in the elevator.
System solutions
dynofil is our total system solution (including services) for
electrical installations for elevators.
Customer value in focus
Datwyler has developed innovative system solutions for electrical installations for elevators. Comprehensive harnessing and
logistics services with modern B2B connectivity round off the
service offering of Datwyler.
Datwyler
143
Product Overview
Suspension devices
for dynofil FL, FM, FH,
module concept and
compensation weight
Installation tools
for simple installation
of FL, FM and FH
dynofil cables
Compensation weight
144
Datwyler
Pre-assembled machine
room cabling (MRC)
ready for installation
Flat cables
FL, FM, FH and
module concept
PVC and zero-halogen
Pre-assembled
hoistway cables/
wires (HW)
ready for
connection
Pre-assembled
travelling
cables (TC)
for travelling
heights up to
400m
Find our products for Elevator cable systems in the respective catalogue.
Datwyler
145
locations
Offices and distribution partners
146
Datwyler
Datwyler
147
Switzerland
Germany
Russian Federation
Great Britain
Datwyler (UK) Ltd
Unit B
Omega Enterprise Park
Electron Way
Chandlers Ford
GB-Hampshire SO53 4SE
T + 44-2380-279 999
F + 44-2380-279 998
info.cabling.uk@datwyler.com
www.datwyler.com
Singapore
Datwyler (Thelma)
Cables+Systems Pte Ltd
29 Tech Park Crescent
SG-638103 Singapore
T + 65-6863 1166
F + 65-6897 8885
sales@datwyler.com.sg
www.datwyler.com