Zero point clear: If there is fluctuation in display when no weights added


on the instruments, please enter the menu and set PF2 = displayed value.
Then it will display 0 when the display value is below PF2.
4.The instrument will return to the measuring estate without any operation
for 25 seconds.
5.When accumulated/average function is needed, the accumulate value will

the value will be added when each operation to SUM .

Operation process
Self check

Power ON

<<

<</Rst

<<

SET

all LED on

PV display
Output value display

COM

AL1

AL2

COM

AL1

AL2

23

24

22
10

12

21
9

11

20
8

19

18

17

16

1 4

15

+
6

4
+

12V

SG

11

OUT

LA8-VNNNA

SET
Response for 20mA/10V output high value
setting,range:0trHUSP

SET
communication address : 000-200, Baud rate:
regular: 9.6KBIT(hidden when there is no output)

SET
LCK=010,is for read only.
LCK=000 means the parameter can be momodified.
Password selection,range:0-200

T
K g
g

0-10V

setting,range:0trLUSP

more than 2 seconds to clear, then displays 0;

be in the Low LED. Press external terminal RST to reset, SUM to add up

1 3

12
Response for 4mA/0V output low value

CND

SET

80-265V AC

SG(mV)

2Used with LOAD cell . The instrument can supply DC 12V


auxiliary power, and the sensor output is 2mV/V. Select input signal mV.

Reserves

press /Rst or external RST

10

SET

0:0000 1:000.0
2:00.00 3:0.000,

mV

is KG) or USP=3000(the unit is Gram)


Without any weight on the load cell,press DOWN key >5s until OK

Decimal point display setting: 0-3

Range: 0-9999 or 0-99999

SET

PF2=0000.eg.load cell scale is 10KG, then set USP=3.000( the unit

The added value when making adjustment,

<<

80-260V AC/DC

terminal RST too.The factory setting is 0.

set USP=Standard weight ( that equal to 20% load cell scale or more),

weight.

<</Rst

AL2 AL1

AL3
12V

SET

well connected wires and sensor, turn the power on,

If big error occurs, just repeat the operation once again.

SET

1Used with 2 wire transmitter. The instrument can supply DC


24V auxiliary power, and isolate analogue output 4-20mA. Select input
signal mA.

E. Press SET key to read and repeat B, C, D steps to modify.


2.Adjustment:

3: Clear tare weight :in display state,

SET

OK flashes.Thats to set the high value. And it displays the added

AL1
AL2
OUT

Load cell

flashes.Thats to set the zero point and it displays 0.0;

LAP 5 digits 48*96*100

Then add the weight equal to setted USP(3kg), press UP key>5s until

Panel

420mA/0-10V

weight(PVF). It can be setted by panel RST key or

B. Press /Rst key, LED flashes,

Range: 50.0
Tare value, Net weight(PV)=the actual weight-tare

Dimension: LA8: 4 digits display, 48H x 96W x 80L


LP5:5 digits display,48H*9W*100L

Hysteresis value setting for all alarms.

1.Parameter setting: In displaying estate,

SET

D. Press SET key to confirm.

L series Weighing Controller

80-265V AC

Application examples
Alarm3 mode setting(Hiden when no AL3)
H: High output
L: Low output

C. Press Up / Down key to modify,

Power Supply: Blank: 80-265V AC/DC


E: 15-30V AC/DC

10 9

SET

N:none
AL2: R:relay S:SSR/LOGIC

N:none
Analogue : Blank: none
I : DC 4-20mA
V: 0-10V

Alarm 3 setting(Hiden when no AL3)


range:LSPAL3USP

Mounting dimensions: 91+0.5 x 45+0.5mm

Parameters setting

+12V

GND SGmV

RST

Alarm 2 mode setting


H: High output
L: Low output

A.Press and hold SET key > 3 sec, enter / quit parameters setting menu.

AL1: R: relay S:SSR/LOGIC

RS232 or RS485 MODBUS RTU protocol

Communication

RXD TXD

Isolated DC24V / 12V / Max 4 0mA or 12V/,ax 150mA

SET

AuxiliaryPower Supply

Regular: mV(Load cell) Others:mA/V or special order


4-20mA/0-10V DC

SET

AL3: R:relay S: SSR/LOGIC

N:none

AL1
AL2
AL3

Input
Analog output

Auxiliary Power:A: DC +12V /40mA


B: DC +24V/40mA C: 12V/150mA

90-260V AC

LA8 4 digits 48*96*80

Alarm 2 setting,range
LSPAL2USP,factory setting: 70.0

Open contact 250V AC 3A or 30V DC 3A COS=1

Relay

Communication interfaceBlank:none
2:R232 4:R485

LA8:16times/sec LP5: 16-128 times/sec

SET

+12V

12 11 10 9

Input Signal: load cell, mA,V,mV,or others

Accuracy
Sampling speed

90-260V AC/DC OR 15-30V AC/DC


5VA
0.3%F.S2digit

GND

Alarm 1 mode setting


H:High output
L: Low output

Code Illustration
L -

SET

Power Consumption

The instrument provides isolated load cell power (regularly one 12V/40mA),
connect with load cell directly,up to 6 outputs controll for groups of batching
or single ; Data/Peak value holding function for choice. RS485 communication
interfaceprovides remote link with computer/PLC. Besides, you can Start/Pause/
Accumulate/Clear tare weight/average/clear zero,etc. with external control
terminal.

up or down key

Specifications
Power

Application

420mA
Sum Rst mV

Alarm 1 setting,range
0AL1USP

MYPIN product!

Before operating this instrument, please carefully read this manual and
fully understand its contents. If any problems, please contact our sales or
distributors whom you buy from. This manual is subject to change without
prior notice.

Connections (If any changed, refer the label on the meter).

Parameter setting(pressSET for 3 seconds to enter or quit)


SET3S

Thanks a lot for selecting

Measuring value/Parameter code display


Parameter value/Peak /control value display
Weight unit lammp
Alarm 1 /2/3 / output lamp
Parameters Select / Confirm key
Shift key / tare weight Clear key

L Series Weighing Batching Controller


Instruction Manual

Complete products contains


1 copy of user manual,
1 inspection QC label,
2 installing brackets,
We are responsible for the overall repairment for the failure
of manufacturing quality within 12 months since the date of
purchase.Repair fee will be charged accordingly for damage caused by
improper use.

On displaying estate, press UP and DOWN key for more than 3 seconds to access to parameter SEL setting.The operation steps

are the same as the other settings. After setting, press UP and DOWN key to quit.This operation is to modify SEL value ONLY. Other
parameters are fixed by manufacturer. Please do not make any change.

Clear zero value setting.When no weight added, the

Adjustment for large-tonnage scale load cell:

display is 0 if the inner value changes within the range of

SET

PF2.The data remains if it is larger than PF2.


For LH85 weighing meter only)

SET

Filter constant, range:0-3. 0 is the fastest,1-3, much


slow, but stable measurement.

Weighing rate setting for large-tonnage weighing.


Factory setting: 1.000

SET

SET
.

Set PVF=0.000,
B. Record the displaying value(PV1) when no weight on the load cells(eg.100.5kg).
C. Add the standard weight (the weight should be larger than 20% of the total load cell weight,eg.500kg).
Recorder the displaying value(PV2)(eg. 630kg).
D. Calculation: The actual weight added(eg. 500kg)/(PV2-PV1) eg.500/(630-100.5)=0.9442.

Calibration password. Factory setting is 015. Set it to 020


when you want to do calibration.

A. Set USP=the total weight of all input load cells(eg. each load cell is 1000KG, 3 load cells in total, the
total weight is 3000kg.Then set USP=3000.).

Zero point adjustment for current/volt output, 4mA/ 0.1V


adjustable. Available when have analog
output. Factory setting,do not make modification.

E. Set weight ratio parameter Ct=0.944.


F. Clear tare weight. After the setting, take away the weight on the load cell. Then clear the tare weight by
pressing RST key on the panel or RST terminal on the backside. The value displayed is the tare weight.
G. Lock the operation. Press UP and DOWN key at the same time to set SEL=X1XX,

Full point adjustment for current/volt output,20mA/


10V adjustable. Available when have analog
output.Factory setting,do not make modification.

of no use
.

of no use
.

of no use
.

Shielding parameter menu setting


Refer to SEL details

If SEL=XXX1XX,
that means the user cant do on-site weight adjustment by pressing UP/DOWN key.
If SEL=XXX0XX,
that means the user can do on-site weight adjustment by pressing UP/DOWN key.
Note:
*** X means the original data. Do not make modification.
***Just make modification to data 1/0
***Factory setting is XXX0XX.
After on-site adjustment,make sure SEL=XXX1XX.This is to avoid incorrect display by users inappropriate key-pressing operation.