You are on page 1of 5

Hilti engineering for

earthquake
applications

Building a future safer from earthquakes: new EU guidelines.


Hilti. Outperform. Outlast.

Hilti engineering for

earthquake
applications

New rating classifications for anchor performance under seismic load: C1 and C2

Post-installed anchor seismic design


EOTA TR045 sets the fastening seismic design standard

New European testing procedure for determining the seismic suitability of fastenings
The seismic pre-qualification of anchors has been regulated in Europe since the release of
ETAG 001 Annex E in early 2013. Anchors subject to this new test procedure must now
incorporate in the ETA all the required seismic design technical data . The suitability for
seismic loading is classified as:

EOTA TR045 sets the standard for the seismic design of steel-to-concrete connections until
the new EN 1992-4 is released (release date pending confirmation).
This code is in full compliance with the standards in the new ETAG 001 Annex E.

ETA seismic category C1 similar to U.S. pre-qualification procedure; only suitable for
non-structural applications according to the EOTA TR045 recommendations

Three design options

ETA seismic category C2 arduous seismic crack movement tests qualify an anchor as
suitable for more demanding structural and non-structural applications

Structural applications
Acceleration (ag.S)
< 0.05g
0.05g to 0.1g
> 0.1g

Building importance
II, III, IV

non-seismic
ETA C2

Non-structural applications
Acceleration (ag.S)

Building importance
II, III

< 0.05g

The design code incorporates three design approaches which are described below. Note
that all three of these approaches are acceptable within their application conditions.

a1) Capacity design


The anchorage is designed for the force corresponding to the yield of a ductile component
or, if lower, the maximum force that can be transferred by the fixture or the attached element.

Building importance
IV

non-seismic

0.05g to 0.1g

ETA C1

> 0.1g

ETA C2

ETA C2

a2) Elastic design


The fastening is designed for the maximum load assuming an elastic behavior of the fastening and of the structure.

b) Design with requirements on the ductility of the anchors


This design for ductile steel failure requires an anchor classified as ductile. Additionally, this
approach is applicable only for the tension component and some provisions require to be
observed in order to ensure that the cause of failure is steel failure.

Hilti engineering services


A team of qualified and experienced engineers is available to
provide you with more detailed information and to help you determine and design the best solution for your particular project.
Tel +44 161 886 1144
Fax +44 161 786 3840
E-mail GBTAS@hilti.com
The map above is based on national earthquake data (for ordinary buildings and ground type A) and provides perspective on the
relevance of the new ETA guidelines in various countries. For more precise information see national regulations.

Hilti engineering for

earthquake
applications

5&EXLOGLQJDYHUDJH

6WUXFWXUD

1RQVWUXF

&RQWHQWV

5&EXLOGLQJDYHUDJH
2IILFH

6WUXFWXUDO
1RQVWUXFWXUDO
&RQWHQWV

5&EXLOGLQJDYHUDJH

+RWHO

Seismic design and specification of anchor connections is crucial in both structural and non-structural
applications.
2IILFH
Seismic-relevant structural applications

Seismic-relevant non-structural applications

Structural connections are vital to ensure that the structure responds


to a seismic event in a proper, predictable manner. Connections
should therefore be clearly detailed in the design phase to make
certain that both contractors and building inspectors comprehend
project specifications.
Firm, well thought out specifications are the best way to ensure that
the designed product is the one that is actually used.

Anchors are often used to fasten non-structural components.


Their design and selection is therefore crucial in terms of minimizing both injuries to building occupants and the costs associated
with seismic events.
As fire is a common byproduct of earthquakes, firestop systems
should be specified in accordance with their ability to withstand
extreme deformation.

Seismic retrofitting (e.g. bracings, shear reinforcement)

Mechanical and electrical supports

Structural steel element connections to concrete

Suspended ceilings and lights

Post-installed rebar connections

Secondary steel connections and fastenings for utilities

Shear wall fastenings

Faade systems: curtain and perimeter walls

Metal deck fastening with powder-actuated fasteners

Firestop cable and pipe penetrations and joints

Repair costs resulting from a seismic event

6WUXFWXUDO
1RQVWUXFWXUDO
&RQWHQWV

20%
40%
40%

RC building average

20%

5&EXLOGLQJDYHUDJH

44%
+RWHO

2IILFH
62%

70%

Office

Hotel

Structural

8%

17% 13%

18%

48%

+RVSLWDO

Nonstructural
Contents

6WUXFWXUDO

Hospital

1RQVWUXFWXUDO

Source: Taghavi S. and Miranda E.: Seismic Performance and Loss Assessment of Nonstructural Building Components, Proceedings of
7th National Conference on Earthquake Engineering, Boston, 2002.
+RWHO

&RQWHQWV

+RVSLWDO

Hilti engineering for

earthquake
applications

Seismic fastening systems

Approved per new European regulations (ETAG 001 Annex E)


ETA seismic performance categories C1 and C2

Hilti HY 200 w / HIT-Z


Fast-curing bonded anchor.
No cleaning required with the innovative HIT-Z rod.

Hilti HST
Medium-duty mechanical anchor.
Designed to excel in cracked concrete.

Post-installed anchor accessory

Hilti dynamic set


Filling washer, conical washer, nut and lock-nut.
Doubles shear resistance and prevents loosening.

Approved per CSTB seismic pre-qualification


Post-installed structural rebar
Reinforced concrete design assumes that concrete has negligible tensile strength while
allowing for the design of rebar development length and avoiding brittle concrete failure, in
the following two situations:
Transferring tensile loads from one bar to another (overlap splice)
Development length of the tensile force in a bar beyond a node in equilibrium

Seismic structural rebar approval


French DTA approvals delivered by CSTB, a member of EOTA, recognizes Hilti HIT-RE
500-SD and HIT-HY 200 injectable mortars as products qualified for structural rebar applications in seismic zones. By applying engineering judgment, engineers can use this French
approval when designing seismic structural post-installed rebar connections.

ETA seismic performance category C1

Hilti HIT-RE500-SD
Slow curing anchor mortar.
Approved with threaded rods and other inserts.

Structural rebar applications

Hilti HUS
Highly efficient medium duty screw anchor.
Ideal for serial applications.

Hilti now tests new anchors according to


the updated seismic pre-qualification.
Find the latest seismically qualified anchor
at www.hilti.com/seismic.

Included in the DTAs


The design bond strength fbd,seism of Hilti mortars considered for use in seismic zones
Formatted data for design with Eurocode 2 and Eurocode 8
Application limit information (e.g. transverse reinforcement, settings instructions)

DTA seismic approval

Hilti HIT-RE 500-SD


Slow-curing anchor mortar.
CSTB approval DTA 3/10-649 for seismic rebar
applications.

Design tools
Design is further simplified by Hiltis own PROFIS software,
which allows users to design fastening systems and rebar connections easily and in accordance with the state-of-the art
seismic code framework.
Additionally, the printed version of the Fastening Technical
Manual (FTM) provides all technical data for both anchoring
and rebar connections.

PROFIS Anchor

PROFIS Rebar

FTM

Download the latest version of Hiltis PROFIS software and the Fastening Technology Manual from www.hilti.com

Hilti engineering for

earthquake
applications

Post-installed anchoring

Post-installed rebar

Fastening structural and non-structural elements according to


new European regulations.

Injectable mortar and everything required for the safe installation


of concrete-to-concrete connections.

Rainscreen Faade

Direct fastening

Aluminum sub construction for light ventilated faade systems

Powder-actuated fastening solutions for metal decking, shear


walls and end lap connections.

Firestop

Installation systems

Solutions for pipe and cable penetrations through floors or


walls, and for fire rated joint seals.

Maximum safety assured by expert design and the use of Hilti


standard pre-design solutions.

Hilti. Outperform. Outlast.


Hilti Corporation I 9494 Schaan I Liechtenstein I P +423-234 2111 I F +423-234 2965 I www.hilti.com/seismic

Hilti = registered trademark of Hilti Corp., Schaan | W4194 0413 0-en | 1 Printed in Liechtenstein | 2013 | Right of technical and programme changes reserved S. E. & O.

Everything you require for easy and reliable seismic


specifications.

You might also like