You are on page 1of 8

Sewage Treatment Plant ACO Aeropur Plus

Sizes 3 100

ACO Aeropur Plus

Characteristic, application

Treatment process

Advantages

The ACO Aeropur Plus sewage treatment plants


are designed for the complete biological purification of domestic wastewater originating
from:
single-houses
residential areas
hotels
boarding-houses
companies, etc.

Mechanical pre-treatment
Biological treatment by activated sludge
Final gravity sedimentation

Easy installation as a compact and lightweight unit


Very stable and high treatment efficiency
during irregular hydraulic and mass load
overload resistant
Effective purification also of total nitrates
(Ntot)
Low maintenance
Low energy consumption

The ACO Aeropur Plus sewage treatment plants comply with all requirements of EN 12566-3.

Blower
Air
Sludge water
Return sludge

Surplus sludge

Inlet

Outlet
1
4

3
2

Key:
1. Primary treatment aerated screen basket
2. Buffer tank
3. Activation
4. Final sedimentation
5. Suplus sludge storage tank

ACO Aeropur Plus

Technology description
The ACO Aeropur Plus technological line consists of mechanical and biological parts.
Mechanical part of the ACO Aeropur Plus is
composed of the aerated screen basket (1)
being submerged into the buffer tank (2).
Sludge water is supplied into the ACO Aeropur
Plus through the inlet pipe whereby it flows into
a screen basket. Coarse-grained matters are
entrapped into the screen basket and pre-treated water passes freely through the basket
screening meshes into the buffer tank space.
Screen basket is aerated intensively from
below. Air flowing through the screen basket
grinds/crushes a part of coarse-grained impurities (left-overs, paper, etc.) which leaves the
screen basket in the form of small particles
together with pre-treated water. This self-cleaning effect of the screen basket extends considerably time period of its filling and even
intervals of its emptying by the operating staff.
Hydraulic peaks at the inlet of the ACO Aeropur
Plus sewage treatment plants are eliminated
with the aid of the buffer tank from where pretreated water is pumped uniformly into the
plant biological part. Hydraulic peak equalizing
supports stable purification efficiency considerably.

Blower

Ventilation

Biological part of the ACO Aeropur Plus consists of the activation tank (3) and the built-in
final sedimentation tank (4).
Activation tank is aerated intermittently by
micro-bubble aeration. Intermittent operation
provides electric power saving up to 50 percent, and simultaneously even better purification efficiency. In the mode of aeration (nitrification) there occur degradation of organic pollution and ammonia. In the mode of aeration
break (denitrification) there is a reduction of
value of nitrogen total volume.
From the activation tank the water flows into
the final sedimentation tank. Then gravitational
separation of treated water from activated sludge is realized there. Treated water flows off the
sewage treatment plant through an outlet unit.
Activated sludge falls down to the bottom of
the final sedimentation tank from where it is
pumped and then returns sludge back to the
activation tank and partly into the storage tank
(5) as surplus sludge.

Surplus sludge is stored separately in the storage tank (5) which is capable of holding it for
100 150 days. Thanks to the separate storage tank surplus sludge does not affect purification efficiency of the ACO Aeropur Plus in any
way.
Pumping of sludge water, return sludge and
surplus sludge is carried out with the aid of airlift pumps in the ACO Aeropur Plus. These
pumps need no maintenance and they are entirely resistant to clogging. Hydraulic capacity
of the pumps is continuously adjustable even
with a very small flow of rate, which helps to
ensure uniform process of purification and thus
stable purification efficiency.
As the only electric appliance of the ACO
Aeropur Plus there is a blower supplying air
into aeration elements in the activation tank
and into air-lift pumps. Blower operation is
time-controlled. Blower intermittent operation
guarantees electric power savings up to 50
percent.

Final sedimentation tank is equipped with a


device for automatic collection and removal of
floating sludge from water level. This device
supports markedly reduction of maintenance
works during operation.

Outlet Unit

Automatic Removing
of Sludge from
Water Surface

Inlet
Final Sedimentation
Buffer Tank
Activation Tank
Aerated
Screen Basket
Microbubble aeration
Air-lift Pump

Surplus Sludge
Storage Tank

ACO Aeropur Plus

Sizing, hydraulic and biological capacity


ACO Aeropur Plus

12

22

35

50

70

100

Hydraulic load [m3/day]

0.45

0.75

1.80

3.30

5.25

7.50

10.5

15.0

Biological load BOD5 [kg/day]

0.18

0.30

0.72

1.32

2.10

3.00

4.20

6.00

25

Calculated values
of hydraulic and biological load

Range of usage
Number of PE

38

8 16

16 28

28 42

42 60

60 85

85 120

Hydraulic load [m3/day]

0.30 0.75 0.45 1.20

1.2 2.4

2.4 4.2

4.2 6.3

6.3 9.0

9.0 12.8

12.8 18.0

Biological load BOD5 [kg/day]

0.12 0.30 0.18 0.48

1.68 2.52 2.52 3.60

3.60 5.10

5.10 7.20

ACO Aeropur Plus 3 12

0.48 0.96 0.96 1.68

H2

H1

H2

H1

H4

H4

ACO Aeropur Plus 22 100

H3

H3

4 2
LxW
D

4
Inlet
DN150
(160)

4
1

2
3

Ventilation
DN100
(110)

Key:
1. Buffer tank
2. Activation tank
3. Final sedimentation tank
4. Surplus sludge storage tank

Outlet
DN150
(160)

Inlet
DN150
(160)

Ventilation
DN100
(110)

Outlet
DN150
(160)

ACO Aeropur Plus

Technical data
ACO Aeropur Plus
Diameter D [mm]

12

1 330

1 470

2 030

Length L [mm]
Width W [mm]
Height H [mm]

2 200

2 550

2 950

22

35

50

70

100

3 000

4 000

5 000

6 160

8 660

2 160

2 160

2 160

2 400

2 400

3 020

3 020

3 020

3 020

3 020

Height of inlet pipe H1 [mm]

860

860

860

880

380

380

380

380

Height of outlet pipe H2 [mm]

980

980

980

1 000

500

500

500

500

Depth of water H3 [mm]

1 200

1 550

1 950

2 000

2 300

2 500

2 500

2 500

Height of ventilation pipe H4 [mm]

720

720

720

720

220

220

220

220

Weight [kg]

187

263

579

891

1 159

1 728

2 149

2 872

405172

405173

Power supply [V/Hz]


Article No.

230/50
405166

405167

405168

3x400/50
405169

405170

405171

Efficiency of purification
The following average values of effluent were
achieved during tests in an accredited laboratory according to EN 12566-3:
BOD5 .................................................9.2 mg/l
COD.................................................60.0 mg/l
TSS ..................................................17.6 mg/l
N-NH4 ................................................2.6 mg/l
Ntot.................................................34.4 mg/l

ACO Aeropur Plus

Adapters of ACO Aeropur Plus


Main tanks of the ACO Aeropur Plus are statically designed for in ground installation without
concrete encasement up to inlet pipeline depth
of 1.35 m. This option offers greater flexibility
during installation of the ACO Aeropur Plus and
better adaptation to local conditions (installation of inlet and outlet pipeline in ice-free depth,
guarantee sufficient slope of the inlet and outlet pipeline, etc.).

To make utilization of the above mentioned


option possible without any expensive construction work, the ACO Aeropur Plus main
tanks are provided with adapters which means
it is possible to heighten the main tank of the
ACO Aeropur Plus quick and easily.

If some adapters are used there, the sewage


treatment plant cover remains the same as
though it were used for the main tank only.

Adapters of ACO Aeropur Plus 3 12


Adapters are of circular ground plans and it is
possible to place them fluently into the main
tank of the ACO Aeropur Plus to any position,
in a range according to the adapter type.
Adapter position is locked by screws. Fluent
height adjustment from 60 to 500 mm allows
either application of two adapters of different
heights individually or both adapters may be fitted together.

Article No.

Article No.

12

60 140
11
405174

Height H [mm]
B Weight [kg]

320 - 500

Height H [mm]
A Weight [kg]

13

16

405175

405176

140 320
19

23

28

405192

405193

405194

140 - 320

ACO Aeropur Plus

60 - 140

A+B

ACO Aeropur Plus

Adapters of ACO Aeropur Plus 22 100


Ground plan dimensions of adapters are consistent with the ACO Aeropur Plus main tank
dimensions. The selected adapter is put on the
main tank and locked by screws. That way it is
possible to raise the main tank height by
500 mm or 1,000 mm, according to the
adapter type. However if the customer
wish it is possible to supply even adapters
being manufactured to order, with their
heights ranging from 200 to 1,000 mm.

ACO Aeropur Plus

22

35

135

161

405177

405179

Height H [m]
Weight [kg]
Article No.

Article No.

70

100

185

263

340

405181

405183

405185

500

Height H [m]
Weight [kg]

50

1 000
240

287

334

466

601

405178

405180

405182

405184

405186

ACO Industries k.s. All reasonable care has been taken in compiling the information in this document. All recommendations and suggestions on the use of ACO products are made without guarantee since the conditions of use are beyond the control of the Company. It is the customers responsibility to ensure that each product is fit for its intended purpose and that the actual conditions of use are suitable. This brochure and any advice is provided ACO Industries k.s. (the company) free of charge and accordingly on terms that no liability (including liability for negligence) will
attach the Companyor its servants or agents arising out of or in connection with or in relation to this brochure or any such advice. Any goods supplied by the Company will be supplied solely upon
its standard conditions of sale, copies of which are available on request. The Companys policy of continuous product development and improvement renders specifications liable to modification.
information provided in this brochure is therefore subject to change without prior notification.

Subject to technical changes without notice


1252/IC Aeropur/En/05/06/JL

ACO Industries k.s.


582 22 Pibyslav
Havlkova 260
Tel.: +420 569 491 111
Fax: +420 569 482 529
www.aco.cz
e-mail: aco@aco.cz
Czech republic

You might also like