TYPICAL MANIFOLD SYSTEM

(SINGLE PRODUCT LINE DELIVERY)

FILL

4 TANK #2

SYPHON SYSTEM 5

FLEX CONNECTOR
(WITH SWIVELS) 2
VENT

BALL VALVE "B" 1


(NORMALLY OPEN)
4 TANK #1

MECHANICAL LINE LEAK DETECTOR


(VENTED BACK TO TANK PORT) 3
LEAK DETECTOR TEE HOUSING

NOTES:
1

MANIFOLDED SYSTEM OPERATION


(FOR DISPENSING ONE PRODUCT WITH TWO SUBMERSIBLES)
IN THIS TYPE OF INSTALLATION, A SUBMERGED PUMP IN
EACH TANK #1 & #2 SUPPLIES ONE DISCHARGE LINE. BY
THE USE OF VALVES AS SHOWN, ONE PUMP WILL SUPPLY
THE DISCHARGE LINE TEMPORARILY. TO USE SUBMESIBLE
TANK #1 ONLY, CLOSE VALVE "B" WITH VALVE "A" NORMALLY
OPEN. TO USE SUBMERSIBLE TANK #2 ONLY, CLOSE VALVE "A"
NORMALLY OPEN.

SWING JOINT MAY BE APPLICABLE REPLACEMENT FOR FLEX CONNECTOR.


PIPING OTHER THAN INDICATED TO BE PER CUSTOMER RECOMMENDATIONS.

MECHANICAL LINE LEAK DETECTORS WILL NOT DETECT LEAKS PRIOR TO


THE LEAK DETECTOR TEE HOUSING. MINIMIZE PIPING BETWEEN THE TEE
HOUSING AND THE SUBMESIBLES.

TANKS RECOMMENDED TO BE OF SAME DIAMETERS OR WITH TOP OF TANKS


ON THE SAME PLANE.
A SYPHON SYSTEM MAY BE DESIRED WITH THIS CONFIGURATION TO UTILIZE
FULL STORAGE CAPACITY OF THE TANKS AND REDUCE THE POSIBILITY OF
RUNNING A PUMP IN A DRY CONDITION. THE SUGGESTED SYPHON SYSTEM
WOULD BE INSTALLED AS SHOWN ABOVE, WITH THE HIGHEST POINTS OF THE
SYPHON LINE CONNECTED AT EACH END TO THE SYPHON CHECK VALVE ASSEMBLY
AT EACH SUBMERSIBLE. THE SYPHON WOULD BE INSTALLED LIKE THAT OF A
TYPICAL SYPHON SYSTEM, REFERENCE ENGINEERING SKETCH ENGSK12 FOR
COMPLETE DETAILS, EXCEPT THE SYPHON LINE MUST BE INSTALLED LEVEL
RATHER THAN PITCHING UP TOWARD EITHER SUBMERSIBLE AS IN A TYPICAL
SYPHON SYSTEM INSTALLATION.

DISCHARGE LINE

BALL VALVE "A" 1


(NORMALLY OPEN)

INSTALLATION MUST CONFORM TO APPLICABLE


NATIONAL, STATE, AND LOCAL CODE REQUIREMENTS
2

ENLARGE TEXT

ENGINEERING RELEASE

REV

-----

DESCRIPTION

ECN NO

The information disclosed hereon includes proprietary rights of FE Petro , Inc. Neither this drawing
nor the information disclosed thereon may be reproduced or transferredto other documents, or used or
disclosed to others for any purpose, except as specifically authorized in writing by FE Petro. This drawing
must be returned to FE Petro upon request.

DO NOT SCALE DRAWING


MATERIAL:
STANDARD INCH TOLERANCES
(UNLESS OTHERWISE SPECIFIED)
UNDER 6"
OVER 6"
SPECIAL DIST:
+ .02
+ .03
.XX .XX HIGH CAP.
+ .005
+ .010
.XXX .XXX + .0005
+ .0010
.XXXX .XXXX MANIFOLD PROD
+ 1/2
+ 1/64
SPARE PARTS
ANGULAR FRACT -

MLD PROD
PIPE PROD
PMA PROD
OTHER

BY

DATE

McFarland, WI 53558

TITLE:

MANIFOLD 2 STP / 1 MLD ISO

CONTROL BOX
DRAWN:
STP PROD
BCG
STP KITTING APPRVL:
DPK

DATE:
DATE:

2/19/97
3/10/97

DRW NO:

ENGSK11A

SCALE:

NONE

SUFFIX:

SHEET 1

--OF 1

You might also like