You are on page 1of 11

PASSENGER ELEVATORS

Principle
Based on our policy, Quality in Motion,

Welcome to a New Era in Vertical Transportation


Introducing the NEXIEZ...

we provide elevators and escalators that will

technologically advanced elevators that consume less power,

satisfy our customers with high levels of

have minimal impact on the global environment and harmoniously serve people

comfort, efficiency, ecology and safety.

and buildings with smooth, seamless operation. The refined design produces a
high-quality atmosphere that reassures passengers of the superior safety and
comfort synonymous with Mitsubishi Electric products. Regardless of the use or
purpose, the NEXIEZ is a best-match solution for virtually any elevator installation.

Contents
Main Features

3-4

Car Designs

5-8

Hall Designs

9-10

Features

11

Electrical Installation

12

Entrance Layout Drawing

13-14

Basic Specifications for Type MR

15-16

Basic Specifications for Type MRL

17-18

Application for Type MR


(m/sec)

1.75

NEXIEZ-GPX
Type MR

1.0

We strive to be green in all of


our business activities.
We take every action to reduce environmental
burden during each process of our elevators
and escalators lifecycle.

450

700

(kg)

750

Application for Type MRL


(m/sec)

1.75

NEXIEZ-GPX
Type MRL

1.0

450
1

550

630

825

(kg)

Main Features

Using Energy Wisely

Flexible Elevator Layout

Our long-term commitment to developing energy-efficient elevators has created systems and functions that
make intelligent use of power.

NEXIEZ-GPX comes in two types: configurations with and without machine room (Type MR and Type MRL).
Choose the configuration that is better suited for the space and other building conditions.

Milestones of Energy-saving Technologies in Elevator Development


1970

Permanent magne

I n d u c t i o n m o to r

Motor

2010

20 0 0

1990

1980

Motor drive

AC2 control

Control circuit

AC V V *1 control

100%

t m o to r

V V VF**22 control

Relay

Power consumption /
CO2 emissions*3

Type MRL
(MRL: Machine-room-less)

G e ar l e ss

Worm geared

Traction machine

Type MR
(MR: Machine room)

Microcomputer

93%

74%

The top machine room,


accommodating bulky
equipment, allows simple
and flexible equipment
layout to fit the hoistway
into a limited space in the
building.

37%
30 %

Approx.

70%

All equipment is installed in


the hoistway. Without the
machine room, the space
on the hoistway gives
architectures and interior
designers greater freedom
in design.

Traction Machine with PM Motor

Emergency Situations

(PM motor: Permanent magnet motor)

Firefighters Emergency Operation (FE) (Optional)

Fire Emergency Return (FER) (Optional)

When the fire operation switch is activated, the car


immediately returns to a predetermined floor.
The car then responds only to car calls which facilitate
firefighting and rescue operations.

When a key switch or a buildings fire alarm is activated,


all cars immediately return to a specified floor and open
the doors to facilitate the safe evacuation of passengers.

The joint-lapped core built into the PM motor of the traction machine features flexible
joints. The iron core acts like a hinge, which allows coils to be wound around the
core more densely, resulting in improved motor efficiency and compactness.
A high-density magnetic field is produced, enabling lower use of energy and resources
and reduced CO2 emissions.

Motor

Motor
Control
panel

Control
panel

Switch

LED Lighting
Used for ceiling lights, LEDs boost the overall energy performance of the building.
Furthermore, a long service life eliminates the need for frequent lamp replacement.

To a specified
floor

Switch

Buildings fire alarm


or return signal
from supervisory room

Firefighter
Emergency
power supply

Normal
power
supply

Emergency
power supply

Normal
power
supply

To a specified
floor

Advantage of LEDs
Earthquake Emergency Return (EER-S) (Optional)

Ceiling: L500

Service life (hr)


LED
Incandescent
lamp

When a secondary wave seismic sensor is activated,


all cars stop at the nearest floor and park there with the
doors open to facilitate the safe evacuation of
passengers.

Power consumption (W)


40000
2000

Approximately 20 times longer

LED
Incandescent
lamp

14.4
132

Motor
Control
panel

Switch

Approximately 88% reduction


Seismic
sensor

Ceiling: L500 LED downlights


Emergency
power supply

Normal
power
supply

To the nearest
floor

Car Designs (1/2)

L500

N520

Ceiling:

Ceiling:

[Center] Painted steel sheet (Black)


[Sides] Painted steel sheet (White)
Lighting: [Center] Fluorescent lamp
[Sides] Downlights (LEDs)

[Center] Brushed stainless-steel


[Sides] Painted steel sheet (Black)
Lighting: Downlights (LEDs)

Car Design Example


Walls
Transom panel
Doors
Front return panels
Kickplate
Flooring
Car operating panel

Car Design Example

- Brushed stainless-steel
- Brushed stainless-steel
- Brushed stainless-steel
- Brushed stainless-steel
- Brushed stainless-steel
- 69
- Type LCD

Walls

- Decorative plastic finish


(4745-60)
Transom panel
- Brushed stainless-steel
Doors
- Decorative plastic finish
(4745-60)
Front return panels - Brushed stainless-steel
Kickplate
- Painted steel sheet
Flooring
- 602
Car operating panel - Type LCD

The ceiling height of the car shown in this design image is 2600mm.

N510

N530

Ceiling:

[Center] Milky white acrylic panel


[Sides] Painted steel sheet (Black)
Lighting: [Center] Fluorescent lamp
[Sides] Downlights (LEDs)

Ceiling:

Car Design Example

Car Design Example

Walls

Walls

- Decorative plastic finish


(7850-60)
Transom panel
- Brushed stainless-steel
Doors
- Decorative plastic finish
(7850-60)
Front return panels - Brushed stainless-steel
Kickplate
- Brushed stainless-steel
Flooring
- 618
Car operating panel - Type LED
5

[Center] Brushed stainless-steel


[Sides] Painted steel sheet (Black)
Lighting: Fluorescent lamp
Downlights (LEDs)

- Decorative plastic
finish (7054-60)
Transom panel
- Brushed stainless-steel
Doors
- Decorative plastic
finish (7054-60)
Front return panels - Brushed stainless-steel
Kickplate
- Brushed stainless-steel
Flooring
- 650
Car operating panel - Type LED
Actual colors may differ slightly from those shown.

Car Designs (2/2)


Car Operating Panels

Materials and Colors

Walls, doors
Stainless-steel

Buttons accented with LED halo illumination


Illuminated characters (CBV1), arrows (PIV1) and halos
attract users attention.
Brushed finish

Decorative plastic finish

Yellow-orange lighting

Illumination
color

Tactile

Stainless-steel with
non-directional brushed f inish

Code No.
All

Type MR

Type MRL

1863K-55

2047-60-100

4166-60

4744-60

4745-60

4746-60

7054-60

7850-60

Y006

Y010

Y017

Y054

Y120

Y010

Y017

Y054

Y120

Painted finish

Configuration
Elevator type*1

D403-60

*2

Location of
car operating panel

Y003

Front return
panel

P08-2S
P11-CO
P11-2S

Front return
panel

P06-2S
P08-CO

Side wall

Transom panel
Stainless-steel

Brushed finish

Flooring

Painted finish

Type LED

Type LCD

Notes:
*1: Appearing fixing method of face plate is slightly different in elevator type.
Please consult our local agents for more details.
*2: The entrance width (JJ) shall be 800mm. For JJ=900mm, please consult our local agents.
69

Interior

602

612

618

650

651

Y003

Y006

Finishes
Application

Mirror

Walls*1

Handrail

Transom panel
Doors
Front return panel
Kickplate

YH-59S

Flooring
Sill

YZ-52A
7

Required

Color No.

Brushed stainless-steel
Decorative plastic finish
Painted steel sheet
Brushed stainless-steel
Painted steel sheet
Brushed stainless-steel
Decorative plastic finish
Painted steel sheet
Brushed stainless-steel
Paint *2
Brushed stainless-steel
Durable vinyl tiles (2mm thick)
Durable rubber tiles (3 or 6mm thick)
Marble (Supplied by customer)
Extruded hard aluminum

- Please consult our local agents.


- Type MR only
Notes: - Applicable
*1: A half-size mirror on the rear wall is available as an option.
*2: Only available in dark gray.

Hall Designs
E-102

E-302

Narrow Jamb

Materials and Colors

Splayed Jamb

Doors and jamb


Stainless-steel

Brushed finish

Painted finish

Y003

Jamb
- Painted steel sheet (Y010)
Doors
- Painted steel sheet (Y010)
Hall position indicator
and hall button
- PIV1-A710

Y006

Y010

Brushed stainless-steel

Sill

PIV1-C720

PIV1-C760

(Type MRL only)

Color No.

Painted steel sheet


Painted steel sheet

Doors

Note:

Required

Brushed stainless-steel

Jambs

PIV1-C710

Y120

Finishes
Application

PIV1-A720

Y054

Jamb
- Brushed stainless-steel
Doors
- Brushed stainless-steel
Hall position indicator
and hall button
- PIV1-C710

Hall Position Indicators and Buttons

PIV1-A710

Y017

Extruded hard aluminum


- Applicable

- Please consult our local agents.

PIV1-C770

(Type MRL only)

10

Electrical Installation

Features

Power Feeder Data

Operational and Service Features


Feature

Abbreviation

1C-2BC

2C-2BC

Required
-

Backup Operation for Car Control Microprocessor

CCBK

Backup Operation for Group Control Microprocessor

GCBK

Backup Operation for Hall Control Microprocessor

HCBK

CCC

Car Call Canceling


Car Fan Shut Off Automatic

CFO-A

Car Light Shut Off Automatic

CLO-A

Continuity of Service

COS

Elevator remote control Car

Capacity
(kg)
450

550

EVRC-C

False Call Canceling Car Button Type

700

FCC-P

Independent Service

IND

Next Landing

NXL

Non-service Temporary Release for Car Call Card Reader Type


Non-service to Specific Floors Switch

for Type MR

#1

750

Overload Holding Stop

OLH

Safe Landing

SFL

Capacity
(kg)
450

Group Control Features


Abbreviation

Forced Floor Stop

FFS

Main Floor Changeover Operation

TFS

Main Floor Parking

1C-2BC

2C-2BC

825

SOHS

Abbreviation

1C-2BC

Door Operation Features


2C-2BC

Required

DSAC

Door Load Detector

DLD

Door Nudging Feature With Buzzer

NDG

DODA

Multi-beam Door Sensor

Reopen with Hall Button

ROHB

RDC

Automatic Door Speed Control

Door Sensor Self-diagnosis

Repeated Door-close

630

Required

MFP

Feature

Abbreviation

Car Arrival Chime Car

AECC

Car LCD Position Indicator

CID-S

Car Top Buzzer

CTBZ

Emergency Alarm Bell #3


Hall LCD Position Indicator

Type MRL

Inter-communication System #3
Voice Guidance System

Feature

1C-2BC

2C-2BC

11

1C-2BC (1-car selective collective), 2C-2BC (2-car group control)


= Standard
= Optional
= Not applicable
#1: NS for 1C-2BC: Up to 20 stops, NS for 2C-2BC: Up to 16 stops
#2: Cannot be combined with ITP, EMB.
#3: When ITP is applied, Emergency Alarm Bell is .

2.8
3.7
6.5
5.1
8.9

15
20
33
25
42

FLAcc (A)

Capacity of
power supply
(kVA)

Breaker in
control panel
(A)

Heat
emissions
(W)

25
34
58
44
75

4
5
7
6
9

20
30
40
30
50

740
960
1520
1190
1930

Current at 200V

When power is supplied to multiple elevators in a group through a common feeder, the capacity of the power supply

transformer, the size of the feeder, and the current rating of the no-fuse (NF) breaker for one elevator are each multiplied
by the corresponding diversity factor below.
Abbreviation

1C-2BC

2C-2BC

Required

EER-S
FER

Notes:

FLU (A)

1.0
1.0
1.75
1.0
1.75

700
850
1500
1100
1900
1200
2050

The wire length for the feeder size must be calculated via the following formula.
Wire length (m) <
= Coefficient* E (V)/FLAcc (A)
(E: power supply voltage (V))
(FLAcc (A): current while accelerating with full load at power supply voltage of 200V)
*Refer to the table below for coefficients.

ITP

Fire Emergency Return

Operation by Emergency Power Source Automatic only

Motor
output
(kW)

20
30
40
30
40
30
50

1.25 (Note) FLU (A)


(FLU (A): current during upward operation with full load at power supply voltage of 200V)
Note: For Type MR, the value is 1.05 for the elevator with the rated capacity 700kg or more and the rated speed 1.75m/sec.

Required

AAN-G

ECL

Mitsubishi Emergency Landing Device

Rated
speed
(m/sec)

4
5
7
5
8
6
9

The feeder must be able to withstand continuous flow of the following current at an ambient temperature of 40C.

PIM-C

Emergency Car Lighting


Firefighters Emergency Operation

26
31
52
39
65
41
70

Feeder Size Calculation

Emergency Operations and Features


Earthquake Emergency Return

16
19
30
23
38
24
40

Note: If power supply voltage (E) is a value other than 200V, FLU current and FLAcc current are obtained via the following formula.
(FLU/FLAcc current (A) at E (V)) = (Current at 200V) (200/E (V))

Type MR

FLAcc (A)

2.8
3.4
5.9
4.3
7.6
4.6
8.1

Heat
emissions
(W)

FLU: current during upward operation with full load at power supply voltage of 200V.
FLAcc: current while accelerating with full load at power supply voltage of 200V.

Signal and Display Features


Feature

FLU (A)

1.0
1.0
1.75
1.0
1.75
1.0
1.75

Capacity of
NF size in
power supply machine room
(A)
(kVA)

Current at 200V

for Type MRL

NS
HOS

Strategic Overall Spotting

Motor
output
(kW)

NSCR-C

Out-of-service by Hall Key Switch

Feature

Rated
speed
(m/sec)

No. of elevators/group
Diversity factor

2
2.0

FE
MELD
OEPS-SA

The current size of the grounding wire is determined according to the current rating of the NF breaker on the power source side.
The current rating of the NF breaker on the power source side should be one level larger than that on the receiving box side

in the elevator machine room or hoistway.


*

Feeder size (mm2)


Coefficient

3.5
6.3

5.5
9.7

8
13.8

14
23.9

22
35.9

30
46.4

38
57.6

50
71.3

60
85

80
105

100
126

125
146

150
166

200
192

250
218

325
244

12

Entrance Layout Drawing


2S (Side Opening)

Entrance width: JJ

150

55

Door elevation (section A-A)

E-302

Keyhole

Keyhole

300

25

Entrance height: 2100


140 60

30

150

150

Finished Min. 50
wall
(by owner)

140 60

Jamb
depth:
min. 130

20

91

10

Entrance width: JJ

JD

10

Entrance height: 2100

35

10

70

50

30 91

30

Sill support
(by owner)

91

30

25

30

30

30
91

Door plan (section B-B)

Door elevation (section A-A)

E-102

E-302
Keyhole

Keyhole

100

100

13

150

Entrance
width:
JJ

150

1200

1200

Finished
floor level
A

Hoistway entrance

Entrance
width:
JJ

1200

Finished
floor level
A

150

Entrance height: 2100

Entrance height: 2100

Entrance
width:
JJ

1200

150

Entrance height: 2100

100
Entrance height: 2100

Entrance
width:
JJ

100

100

120

120

100

25

91
Finish

30

55

E-102

Wall

300

60
140

30

30

Door plan (section B-B)

Sill support
(by owner)

(Min. clearance)

70
25

140 60

30

150
150

100
150

Finished
wall
(by owner)

75~113

10

20
90

Entrance width: JJ

100

E-302

Finish

Finished
wall
(by owner)

25

Entrance height: 2100

Entrance height: 2100


30

10
38

300

E-302
(Min. clearance)

E-102

70

E-102

300
35

70

100
150

Jamb depth:
min. 130

55
30

30
55

80
Finish

(Min. clearance)

30
100

E-302
Sill support
(by owner)

E-302

4
50
Finished wall
(by owner)
Entrance width: JJ

10

10

30
55
Wall

38

Finish

Sill support
(by owner)

E-102
55

E-102

(Min. clearance)

CO (Center Opening)

Finished
floor level

Finished
floor level

Hoistway entrance
14

Basic Specifications for Type MR


Horizontal Dimensions

Hoistway Plan

Hoistway Section

Machine Room Plan

800 *1

14001030

2S

800

11001400

800 *1

14001250 *2

P10

10

700

CO

800 *1

14001250

P11

11

750

2S

800

13501400

17501400
18001530
16001750
17501590
18001830
16002050
21001460
21001600
17501810
20501800

18502700
18502050
18002980
18502900
18502200
18003280
21002050
21002050
18503100
20502200

R6

R5

Entrance
width: JJ

R4
Control
panel

Lighting outlet (by owner)

Car internal
width: AA

[ Terms of the table]


The contents of this table are applied to standard specifications only. Please consult our local agents for other specifications.
Rated capacity is calculated at 75kg per person, as required by the Building Standard Law of Japan, 2009.
CO: 2-panel center opening doors, 2S: 2-panel side sliding doors.
Minimum hoistway dimensions (AH and BH) shown in the table are after waterproofing of the pit and do not include plumb tolerance.
This table shows specifications without the fireproof landing door and counterweight safety.
[Notes]
*1: Entrance width(JJ) of 900mm is also applicable. For minimum hoistway dimensions, etc., please consult our local aqents for details.
*2: This counterweight position or dimension is not available in some areas. Please consult our local agents for details.

R2

Ventilator
(by owner)

Power-receiving box
(by owner)
Power outlet (by owner)

Shown for CO doors


Counterweight rear drop

Ceiling height
2300 (standard)

CO

Rear
Side*2
Rear*2
Rear
Side*2
Rear*2
Side
Side
Rear
Side

Overhead: OH

11001100

R3

Entrance height: HH
2100 (standard)

800

R1

Machine room clear height: HM


2200

1400850

2S

Access door
Width: 700
Height: 2000

800 *1

Hoistway depth: BH

1.0
1.75

CO

Car internal
depth: BB

550

P8

1.0

450

P6

Hoistway width: AH

Ventilation
grille
Machine room depth: BM

Machine room clear width: AM

Required

Machine room clear width: AM

Vertical Dimensions

R1

4400
4400
4630
4630

1360
1410

2200
2200

2500
2500*1*1

20

JJ

Control
panel

AA

[Terms of the table]


The contents of this table only apply to standard specifications without counterweight safety. Please consult our local agents for other specifications.
[Note]
*1: Some specifications require more than 2500mm as a minimum floor height. Please consult our local agents if the floor height is less than entrance height HH + 700mm.

R2

Lighting outlet (by owner)


Power-receiving box
(by owner)

Pit depth: PD

60
60
70
70

R4

Access door
Width: 700
Height: 2000

450,
450, 550,
550, 700,
700, 750
750
550,
550, 700,
700, 750
750

Ventilator
(by owner)

Ventilation
grille
Machine room depth: BM

BB

R5

1.0
1.0
1.75
1.75

BH

R6

Power outlet (by owner)

Shown for 2S doors


Counterweight rear drop

Reaction Loads

R5

Machine room clear width: AM

450

11001100

1.0
1.0

14001030
1.75
8

550
1.0
11001400
1.75
1.0

10

700

14001250
1.75

11
15

750

13501400

1.0
1.75

Rear
Side
Rear
Side
Rear
Side
Rear
Side
Rear
Side
Rear
Side
Rear
Side
Side

R2

R3

R4

16
16
14
19
15
17
15
16
15
17
16
19
19
20
21
22
23

21
22
22
24
25
24
26
25
24
25
25
26
26
27
29
29
30

9
9
11
10
12
10
13
9
12
9
13
10
11
11
12
13
13

R5

R6

53

46

R6
R5

61

51

61

52

61

51

61

52

68

56

70

58

77

64

JJ
AA

Note: Hoistway section for counterweight side


drop is slightly different from this figure.

R3

R4

R1

R2

Lighting
outlet
(by owner)
Powerreceiving box
(by owner)
Power outlet
(by owner)

R6

Machine room depth: BM

R1
21
22
20
24
22
25
23
25
22
25
22
26
26
27
28
29
29

Ventilation
grille

AH

BB

1400850

Reaction loads(kN)

BH

Counterweight
position

Floor to floor height

R3

Travel: TR

AH

Control
panel

Ventilator
(by owner)
Access door
Width: 700
Height: 2000

Shown for 2S doors


Counterweight side drop

16

Basic Specifications for Type MRL


Horizontal Dimensions

Hoistway Plan

Hoistway Section

Required
Hoistway width: AH

800 *

13501400

Side

15001740
18001720
16501800
20251720
19001800

R4
Car internal
width: AA

R6
R3
R2

[ Terms of the table]


The contents of this table are applied to standard specifications only. Please consult our local agents for other specifications.
Rated capacity is calculated at 75kg per person, as required by EN81-1.
CO: 2-panel center opening doors, 2S: 2-panel side sliding doors.
Minimum hoistway dimensions (AH and BH) shown in the table are after waterproofing of the pit and do not include plumb tolerance.
This table shows specifications without the fireproof landing door and counterweight safety.
[Notes]
*1: Entrance width(JJ) of 900mm is also applicable. For minimum hoistway dimensions, etc., please consult our local agents for details.
*2: This counterweight position or dimension is not available in some areas. Please consult our local agents for details.

Shown for CO doors


Counterweight side drop

1.75

825
450, 630, 825

TR <
= 30
30 < TR <
= 60
TR <
= 30
30 < TR <
= 60
TR <
= 30
30 < TR <
= 60
60 < TR <
= 70

AH

3850*1
3900*1
3900
3950
4050
4100
4150

1300*1
1350

20

2500*2

R4

1450
1500
1550

R6

[ Terms of the table]


The contents of this table are applied to standard specifications only. Please consult our local agents for other specifications.
This table shows specifications without counterweight safety.
[Notes]
*1: If the capacity is 630kg and marble (supplied by customer) is selected for flooring finish, the dimension may be changed. Please consult our local agents for details.
*2: Some specifications require more than 2500mm as a minimum floor height. Please consult our local agents if the floor height is less than entrance height HH + 700mm.

Reaction Loads

450
630
825

9501300
11001400
13501400

R3
R2

R5
R1

JJ

Reaction loads(kN)
6
8
11

AA

Floor to floor height

1.0

R1

Entrance
width: JJ

Vertical Dimensions

450, 630

R5

1.0
1.0
1.75

Entrance height: HH
2100 (standard)

11001400

Ceiling height
2300 (standard)

9501300

800 *

Overhead: OH

825

800

Travel: TR

11

1.0
1.75

2S
CO
2S
CO
2S

R1

R2

R3

R4

R5

R6

31
43
48

22
32
35

23
33
35

18
26
28

61
80
92

52
68
76

Shown for 2S doors


Counterweight side drop
Pit depth: PD

P11

1.0

Hoistway depth: BH

630

BH

450

Car internal
depth: BB

P8

BB

P6

R5

17

R6

18

State-of-the-Art Factories
For the Environment. For Product Quality.
Mitsubishi Electric elevators and escalators are currently operating in approximately 90 countries around the globe. Built placing priority on
safety first, our elevators, escalators and building system products are renowned for their excellent efficiency, energy savings and comfort.
The technologies and skills cultivated at the Inazawa Works and 13 overseas manufacturing factories are utilized in a global network that
provides sales, installation and maintenance in support of maintaining and improving product quality.
As a means of contributing to the realization of a sustainable society, we consciously consider the environment in business operations,
proactively work to realize a low-carbon, recycling-based society, and promote the preservation of biodiversity.

Certification
Mitsubishi Electric de Mexico, S.A. de C.V. has acquired ISO 9001
certification from the International Organization for Standardization
based on a review of quality management.
The plant has also acquired the certification of INDUSTRIA LIMPIA,
based on the audit of corresponding program.

Eco Changes is the Mitsubishi Electric Groups environmental statement,


and expresses the Groups stance on environmental management.
Through a wide range of businesses, we are helping contribute to the
realization of a sustainable society.

Visit our website at:

http://www.MitsubishiElectric.com/elevator/

New publication effective Oct. 2016.


Specifications are subject to change without notice.
C-CL1-6-C9896-A INA-1610 Printed in Japan (IP)

2016

You might also like