ARCHITECT
24' - 0"
TRASH BINS
NERI ARCHITECTS
2' - 0"
50.00'
2' - 0"
OWNER INFO
1
8' - 6"
17' - 0"
2
19' - 0"
36' - 0"
1,800.0
4.0
S.F.
D.U.
ACTUAL
NUMBER OF UNITS
LOT AREA / UNIT
4
2,152.2
D.U.
S.F./D.U.
SCOPE OF WORK:
APPLICABLE CODES:
8' - 6"
16' - 0"
24' - 7 3/4"
2,509.85
683.88
S.F.
S.F.
2,509.85
2,509.85
2,509.85
S.F.
S.F.
S.F.
10,723.28
S.F.
1.2
BUILDING DESCRIPTION
0.0
S.F.
USE GROUP:
2,509.85
683.88
S.F.
S.F.
3,193.73
S.F.
LOT COVERAGE
.37
4,304.5
S.F.
3,193.73
2,830.66
S.F.
S.F.
6,024.39
S.F.
2,584.61
S.F.
2,582.7
S.F.
REQUIRED # OF PARKING:
RES: 2 SP/D.U.
SP
PROPOSED SPACES
GARAGE
SURFACE
4
4
SP
SP
SP
R-2
CONSTRUCTION TYPE:
III-B
BULDING AREA:
10,723.28 S.F.
ZONING DATA
ZONING DISTRICT:
R-4
9' - 4"
SHEET INDEX
A6-1.1
A6-1.2
A6-1.3
A6-1.4
A8-1.1
50' - 8"
67' - 0"
4 STORY BRICK
AND BLOCK AND
FRAME
RESIDENTIAL
BUILDING
A0
G-2.1
A2-1.1
A2-1.2
A5-1.1
A5-1.2
A5-1.3
171.51'
172.93'
CONC. WALK
UP
UP
S-1
S-2
CONC. WALK
M1-1.1
M1-1.2
E1-1.1
E1-1.2
P1-1.1
P1-1.2
L-1
39' - 4"
PROJECT #
1634
DATE:
09.29.16
SITE PLAN
GENERAL NOTES
FIRST FLOOR PLAN
TYPICAL FLOOR AND ROOF PLANS
SOUTH & EAST ELEVATIONS
NORTH AND WEST ELEVATIONS
GARAGE FLOOR PLANS AND
ELEVS
WALL SECTIONS
BUILDING SECTIONS
STAIR SECTIONS
PARTIAL STAIR PLANS
PARTITION DTLS & NOTES/ DOOR
SCHEDULE
FOUNDATION PLAN FIRST FLOOR
FRAMING
2nd FLOOR & ROOF FRAMING
PLANS
1st & TYP FLR MECH PLANS
ROOF MECH. PLAN SCHEDULES,
NOTES & DTLS
FIRST FLOOR ELEC PLAN
TYPICAL FLOOR ELECTRICAL PLAN
FIRST AND TYP FLR PLUMBING
PLNS
PLUMBING DIAGRAMS AND NOTES
LANSCAPE PLAN NOTES & DETAILS
5' - 8"
25' - 0"
5' - 0"
R-4
CODE SUMMARY
PAVEMENT
8,609.0
ALLOWED
MIN LOT AREA/D.U.
NUMBER OF UNITS
79' - 7 3/4"
LOT AREA:
S.F.
ZONING DISTRICT:
MIN LOT AREA CALCULATIONS
4 CAR
DETACHED
GARAGE
515 SUMMIT
RENE LAMAGNA
132 CALAIS ST
LAGUNA NIGUEL, CA 92677
PROJECT DATA
ADDRESS:
18' - 6"
5' - 6"
PROJECT DATA
1 8 F T G R A V E L A L L E Y
LOCATION MAP
50.00'
SITE LOCATION
CONC.
DRIVE
10.26.16
S U M M I T A V E .
1
A0
SITE PLAN
DRAWN BY:
AS NOTED
DESCRIPTION:
SITE PLAN
A0
GENERAL NOTES
1.
1.
1.
1.
2.
2.
2.
THESE DRAWINGS INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF THE
ARCHITECTURAL DESIGN CONCEPT, DIMENSIONS, MAJOR ELEMENTS AND MATERIALS. THESE
DRAWINGS DO NOT NECESSARILY INDICATE OR DESCRIBE ALL WORK REQUIRED FOR THE
FULL COMPLETION OF THE PROJECT
3.
ALL FLOOR JOISTS SHALL BE 14" DEEP OPEN WEB BY "TRUS-JOIST" CORP. @
16" O.C. (UNLESS NOTED OTHERWISE). STAIR HEADERS TO BE 11-7/8" DEEP
TJI (GIRDER TRUSS) AND TRIMMERS TO BE 2 - 1 3/4" x 14" "MICRO-LAM"
(UNLESS NOTED OTHERWISE). FURNISH ONE (1) SET OF SEPIA SHOP
DRAWINGS TO THE GENERAL CONTRACTOR TWO (2) WEEKS PRIOR TO
FABRICATION FOR REVIEW AND COMMENT, AND SHALL BE SIGNED AND
SEALED BY A REGISTERED STRUCTURAL ENGINEER LICENSED IN THE STATE
OF ILLINOIS. ANY MATERIALS DELIVERED TO THE JOB SITE WITHOUT
APPROVED SHOP DRAWINGS WILL BE REJECTED. ALSO THE TRUSS
MANUFACTURER SHALL SUPPLY THE GENERAL CONTRACTOR WITH A COPY
OF HIS CERTIFICATE OF INSURANCE. SEE 06190 AND 06195 FOR PRODUCT
SPECIFICATIONS AND INFORMATION.
2.
3.
3.
THE GENERAL CONTRACTOR AND HIS SUBCONTRACTORS SHALL FURNISH ALL OF THOSE
ITEMS AND LABOR REQUIRED FOR THE FULL COMPLETION OF THIS PROJECT IN A FIRST CLASS
WORKMANSHIP LIKE MANNER.
4.
ALL INTERIOR BEARING WALLS AND SHAFTS SHALL BE (1) ONE HOUR RATED CONSTRUCTION
USING 5/8" TYPE-X U.L. RATED DRY WALL (BOTH SIDES)
5.
THIS CONTRACTOR SHALL INSTALL SMOKE DETECTORS AS REQUIRED BY THE CITY OF PARK
RIDGE CODE
6.
INTERIOR FINISHES SHALL NOT EXCEED CLASS 1, 0-25 FLAME SPREAD, 200 SMOKE.
7.
8.
THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THE ADHERENCE TO COMPLY WITH ALL
APPLICABLE CITY, STATE, AND NATIONAL CODES AND ORDINANCES.
9.
THE CONTRACTOR SHALL VERIFY ALL PARTITION LAYOUTS WITH THE ARCHITECT BEFORE
PROCEEDING WITH ANY FRAMING.
9.
10.
11.
12.
13.
14.
6.
7.
8.
10.
ALL WELDED WIRE MESH SHALL BE LAPPED (2) TWO FULL MESH
PANELS AND TIED SECURELY. WELDED WIRE MESH SHALL
CONFORM TO "ASTM" A-185 SPEC.
10.
11.
12.
13.
14.
ALL WINDOW GLASS, MIRRORS, FLOORS AND WALL TILE SHALL BE CLEANED AND WASHED
UPON COMPLETION OF THE PROJECT BY THE GENERAL CONTRACTOR.
15.
THE PREMISES SHALL BE KEPT IN A BROOM SWEPT FINISH CONDITION DURING ALL PHASES OF
THE CONSTRUCTION. (ALL CONTRACTORS AND SUBCONTRACTORS SHALL BE RESPONSIBLE
FOR CLEANING UP AND DISPOSING OF THEIR LITTER AND LEFT OVER MATERIALS ON A
REGULAR BASIS AND LEAVE THE PROJECT IN A BROOM SWEPT FINISH CONDITION UPON
COMPLETION OF THEIR PORTION OF THIS PROJECT).
16.
17.
ALL WORK SHALL BE COORDINATED WITH ALL OTHER TRADES IN ORDER TO AVOID
INTERFERENCE, PRESERVE MAXIMUM HEAD ROOM AND AVOID OMISSIONS.
18.
19.
ALL WORK PERFORMED MUST COMPLY WITH THE CITY OF PARK RIDGE CODE.
20.
THE EXCAVATOR SHALL REMOVE ALL EXCESS MATERIAL DOWN TO 6" (SIX INCHES) BELOW
FINISH GRADE, INCLUDING PARKWAYS.
21.
THE ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL ONE (1) 4 x 4 WOOD POST WITH A
TEMPORARY METER HEAD AND TWO (2) 110 V. AND ONE (1) 220 V.OUTLET TO BE USED BY ALL
OTHER TRADES DURING THE COURSE OF CONSTRUCTION OR UNTIL EACH UNIT IS ELECTRIFIED
AND SHALL BE BILLED TO THE GENERAL CONTRACTOR.
STD. 90
HOOK
22.
23.
24.
ALL CONTRACTORS AND THEIR REPRESENTATIVES WORKING ON THIS PROJECT SHALL AT ALL
TIMES PRIOR AND DURING THE COURSE OF THEIR ACTIVITY BE RESPONSIBLE FOR THE SAFETY
OF THEIR EMPLOYEES, AS WELL AS OTHERS AND IN THE CARE OF THE PROPERTY. EACH AS
REPRESENTATIVES OF THEIR EMPLOYEES SHALL ASCERTAIN THAT THE CONDITIONS UNDER
WHICH THEY WILL BE REQUIRED TO ACCOMPLISH THEIR WORK ARE SAFE WITHIN GOOD
SAFETY PRACTICES AND MEET ALL CONCERNED REGULATIONS OF THE OCCUPATIONAL SAFETY
AND HAZARD ACT OR OTHER GOVERNING REGULATIONS. THE BEGINNING OF WORK BY A
CONTRACTOR SHALL INDICATE SATISFACTION CONCERNING SAFETY AND FULL RESPONSIBILITY
FOR ACCIDENTS OR DAMAGE. IF UNSATISFIED, THE CONTRACTOR SHALL INDICATE WHAT SO
EVER ACTION OR DEVICES NECESSARY TO RENDER SAFETY CONDITIONS FOR LIFE AND
PROPERTY AS ARE RELATED TO HIS ACTIVITY. IF THE WORK OF OTHER PARTIES OUTSIDE OF
THEIR ORGANIZATION IS UPON INSPECTION FOUND AT ANY TIME TO BE UNSAFE, HE SHALL
STOP WORK IMMEDIATELY AND NOTIFY THE GENERAL CONTRACTOR, ARCHITECT AND OWNER.
THE BEGINNING OF WORK SHALL INDICATE SATISFACTION. ACCEPTANCE OF A CONTRACT
SHALL INDICATE ACCEPTANCE OF THESE REQUIREMENTS.
11.
14.
15.
16.
13.
14.
15.
16.
18.
19.
17.
18.
MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR THE PREENGINEERED OPEN WEB FLOOR JOISTS SHALL BE ON THE JOBSITE AT THE
TIME OF INSPECTIONS.
36 DIA. LAP.
1
A-1
1
A-1
1
A-1
1
A-1
1D
1C
1A
1B
SECOND FLOOR
ELEV: + 11'-8"
+8'-8"
A 01
01
WALL
CONST. JOINT
1
A-1
WINDOW TAG
13.
PARTITION TAG
10.
17.
DOOR TAG
12.
6.
7.
8.
9.
15.
INTERIOR ELEVATION
12.
CONCRETE COVER SHALL BE 1" TOP AND BOTTOM FOR SLABS; 1-1/2"
FOR BEAMS ,COLUMNS AND WALLS; 3" FOR FOOTINGS, MATS AND
GRADE BEAMS.
16.
4.
11.
SYMBOLS LIST
5.
9.
3.
6"
36 DIA.
PROVIDE CORNER
BARS SAME SIZE
AND SPACING
AS HORIZONTAL
BARS
WALL
CORNER
2'-0" MIN.
8.
EXPANSION AND CONTROL JOINT FILLERS SHALL BE PREFORMED RUBBER. THE EXTENT AND LOCATION SHALL BE AS
INDICATED ON THE PLANS.
5.
36 DIA.
7.
6.
4.
6"
5.
36 DIA.
4.
PROVIDE DOWELS
SAME SIZE AND
SPACING AS
HORIZONTAL BARS
WALL
INTERSECTION
25.
26.
NORTH ARROW
27.
PROJECT #
1634
DATE:
09.29.16
10.26.16
FRAMING NOTES
MASONRY NOTES
DRAWN BY:
THIS SET OF PLANS IS PROTECTED UNDER UNITED STATES GOVERNMENT COPYRIGHT LAWS
AND MAY NOT BE REPRODUCED, REPRINTED OR COPIED IN ANY MANNER, EXCEPT BY
APPROVAL OF ARCHITECT IN WRITING. ANY PERSON OR FIRM KNOWINGLY REPRODUCING,
REPRINTING, OR PHOTOCOYPING ANY OF THIS WORK WILL BE SUBJECT TO LAWSUITS AND
SUCH PENALTIES AS THE LAW ALLOWS.
SCALE:
AS NOTED
DESCRIPTION:
GENERAL NOTES
THESE DRAWINGS WERE PREPARED UNDER MY DIRECTION AND ARE CORRECT TO THE BEST
OF MY KNOWLEDGE IN ACCORDANCE WITH THE BUILDING LAWS OF CITY OF PARK RIDGE.
FZM
SHEET NO.
G-2.1
A5-1.2
4' - 8"
39' - 4"
1
A6-1.2
16' - 9"
17' - 11"
16' - 1"
18' - 7"
14' - 3"
3' - 6 1/4"
1' - 10"
5' - 9"
5' - 9"
3' - 6 1/2"
2
A6-1.1
1' - 0"
5B
A.1
4' - 8"
HANDRAIL
3' - 7 1/4"
9' - 7"
2
8' - 4"
A6-1.3
1B
3 1/2"
4 3/4"
1' - 2 1/2"
FD
1A
6' - 6"
17R @ 6.70"
16T @ 11"
8' - 9 3/4"
1A
STORAGE
113
LIGHT SWITCH
EXIT SIGN TO BE
MOUNTED ON STRIKER
SIDE OF DOOR
5B
BEDROOM 2
104
4"
1' - 10 1/2"
24' - 4 1/2"
EQ
5B
5B
A6-1.1
2'-10"
8' - 0 1/4"
3' - 2 1/4"
3' - 1 1/2"
3' - 7 1/4"
11' - 4 1/2"
5' - 10 1/2"
TO THE BOTTOM
INTERIOR OF THE
CABINET
9' - 2"
1' - 6"
5' - 3"
17' - 5"
8' - 0 1/2"
8' - 0"
16' - 0 1/2"
39' - 4"
1
8"
1'-3"
EXIT
N 08
03
1' - 6"
CL
ELECTRICAL / PHONE / DATA
OUTLETS
10' - 0"
1' - 2 1/2"
6'-0" - 7'-0"
PULL
CL
3'-8"
4'-0"
CL
3'-8"
CL
6'-8"
6'-6" MIN
112
8' - 11 3/4"
6"
TERRACE
2' - 11 1/2"
4' - 4 1/2"
2' - 3"
4"
5' - 1 1/2"
PULL STATION
7' - 0"
THERMOSTAT
1
5' - 1"
CL
3' - 10"
6' - 11 1/2"
4"
N 06
05
S&R
1' - 6"
N 07
05
EQ
5B
C
6' - 7"
6' - 6 3/4"
EQ
4 3/4"
EQ
2' - 4"
2' - 3 1/4"
S&R
1B
5"
EXIT
67' - 0"
5' - 9"
4"
9' - 0 1/2"
5' - 0"
1' - 4 1/2"
5B
HANDRAIL
1A
3' - 5 1/2"
114
A5-1.1
B 10
06
5B
1' - 2 1/2"
111
3
A6-1.3
2' - 11 1/2"
STAIRS #1
8 3/4"
6 3/4"
8"
5' - 4"
LOBBY
6"
106
4 MAILBOXES
6 3/4"
3' - 5 1/2"
17' - 1 1/4"
09.29.16
2"
BATH 2
14' - 11 1/2"
UP
21' - 5"
3' - 5 1/2"
2' - 4"
6' - 10 3/4"
1B
2' - 0"
5' - 0"
6' - 7 1/2"
N 09
03
17' - 5 1/2"
2' - 3 1/4"
101
4' - 9 1/4"
SEAT
3' - 8"
N 07
05
B 02
02
LIVING/ DINING
DATE:
EQ
6' - 9"
1B
1634
36' - 10 1/2"
5' - 0"
6 3/4"
5' - 4 1/2"
EQ
EQ
S&R
EQ
4"
7' - 10"
6' - 9 1/2"
5
WH
A6-1.3
3' - 2 1/2"
105
110
9' - 7"
13' - 6 1/2"
MASTER
BATHROOM
5' - 0"
2B
5B
7' - 9 1/2"
4"
4' - 6 3/4"
N 03
03
MECH CLOSET
FD
PROJECT #
4"
3"
5' - 0"
10' - 3"
1' - 0"
4' - 11 1/2"
5B
2B
4"
ISLAND
SINK
18' - 3 1/2"
2B
1' - 0"
103
A5-1.2 2
F-1
KITCHEN
DW
7' - 3"
RANGE
109
N 08
04
5' - 6"
5B
HALL
SHELVES
EQ
EQ
108
S&R
2B
6' - 10 1/4"
6"
1' - 9 1/4"
N 07
05
N 03
04
WIC
3' - 8 1/4"
6 3/4"
1A
9' - 0"
N 07
05
EQ
117
1B
REF.
3' - 11 3/4"
S&R
SPRINKLER RM
N 03
03
3' - 8 1/4"
2' - 0"
4" 4"
N 04
04
S&R
L.T.
EQ
FD
107
7' - 9"
FD
11 1/2"
4"
4' - 8 1/2"
34' - 10"
A6-1.1
3' - 0 1/4"
B 10
06
600 AMP
MAIN PANEL
ELECTRICAL RM
A6-1.2
8' - 2 3/4"
B 10
06
LAUNDRY /
MUDROOM
2 STACKED
STORAGE
CAGES 1B
116
50' - 8"
3' - 7 3/4"
6' - 10 3/4"
118
100 AMP
COMMON
HOUSE PANEL
67' - 0"
7' - 6"
2 STACKED
STORAGE
CAGES
STORAGE
6' - 10"
8"
1B
5' - 10 1/2"
B 10
06
102
B 02
02
8"
13' - 0 1/4"
4' - 10"
8' - 1 1/4"
3' - 3 1/4"
8 1/2"
HANDRAIL
MASTER
BEDROOM
7' - 10 3/4"
115
4' - 3 1/4"
UP
3' - 8"
17R @ 6.70"
16T @ 11"
13' - 5 1/4"
1
A6-1.4
STAIRS #2
20' - 4 1/4"
12' - 7 1/4"
B 01
01
10.26.16
DRAWN BY:
AS NOTED
DESCRIPTION:
A5-1.1
DEVICE LOCATION
1/2" = 1'-0"
1
A2-1.1
1st FLOOR
SCALE: 1/4" = 1'-0"
SHEET NO.
A2-1.1
3
A5-1.2
4' - 10 3/4"
2' - 7 1/4"
39' - 4"
15' - 10 1/4"
8"
15' - 2"
11 1/2"
9' - 7 3/4"
2' - 11 1/4"
2' - 7"
18' - 7"
A6-1.2
16' - 8 1/4"
11 1/2"
5' - 9"
5' - 8 1/2"
5' - 6"
2' - 7 3/4"
42" HT ALUMINUM
RAILING WITH
TEMPERED
GLASS PANELS
5' - 6"
7' - 7"
A6-1.1
4
BALCONY
MASTER
BEDROOM
1B
UP
202
8"
4 3/4"
9' - 0 1/2"
4A
6' - 8"
3' - 5 1/2"
9' - 7"
4
A6-1.3
214
1A
1A
STAIRS #1
4"
2' - 0"
17' - 5"
BALCONY
11' - 7 1/4"
2 1/4"
EQ
BEDROOM 2
204
4A
4A
4A
8"
1' - 6"
8' - 11 3/4"
212
2' - 11 1/2"
9' - 1"
4"
1' - 10 1/2"
5' - 1"
6' - 1 1/2"
N 06
05
N 05
03
S&R
4"
6"
EQ.
8' - 0 1/4"
3' - 5 1/2"
3' - 1 1/2"
2' - 10 3/4"
3A
6' - 9 1/4"
N 07
05
EQ
4' - 7 1/2"
4' - 10 3/4"
6' - 3 3/4"
11 1/2"
H.P.
6' - 0 1/4"
8"
EQ
1' - 2"
S&R
1B
2' - 4"
2' - 0"
2' - 6 1/2"
2' - 3 1/4"
215
66' - 9 1/4"
8"
3' - 5 1/2"
STORAGE
A5-1.1
10
B 10
06
17R @ 6.70"
16T @ 11"
6"
3A
213
UP
6 3/4"
8"
14' - 0 1/4"
1A
3' - 5 1/2"
09.29.16
6"
4"
207
4"
8"
DATE:
17' - 9 3/4"
BATH 2
23' - 9 1/2"
A6-1.2
16' - 3 1/2"
2' - 3 1/4"
201
2' - 8"
VESTIBULE
A6-1.3
DN
1B
1634
5"
2B
6' - 10 3/4"
1A
B 02
02
17R @ 6.70"
16T @ 11"
3' - 2 1/2"
33' - 10 3/4"
SLOPE 1/4" MIN.
11 1/2"
5
SEAT
N 07
05
N 09
03
PROJECT #
EQ
1' - 2"
7' - 9 1/2"
5' - 0"
5' - 4 1/2"
EQ
EQ
2B
6' - 9"
8"
LIVING / DINING
7' - 2 1/2"
S&R
6"
7' - 10"
4 3/4" 206
5' - 0"
EQ
3A
ROOF ACCESS
HATCH
MASTER
BATHROOM
3' - 0"
4' - 6 3/4"
WH
3' - 0 1/4"
5' - 0"
10' - 3"
1' - 0"
5' - 4 1/2"
N 03
03
3' - 3 1/4"
ISLAND
S&R
FD
N 07
05
2B
F-1
3A
2B
209
6 3/4"
3' - 8 1/4"
EQ
1' - 0"
203
SINK
18' - 3 1/2"
211
N 03
04
WIC
3' - 8"
EQ
KITCHEN
DW
7' - 3"
GFI
MECH CLOSET
N 08
04
A5-1.2 2
2B
SHELVES
5' - 6"
RANGE
BATHROOM
EXHAUSTS
HALL
210
S&R
1' - 9 1/4"
GFI
S&R
3' - 8 1/4"
6 3/4"
EQ
2' - 9"
2' - 0"
EQ.
N 03
03
4" 4"
3' - 11 3/4"
N 08
04
EQ
EQ
2' - 0"
N 03
03
3' - 3"
N 04
04
6' - 10 1/4"
4' - 6 3/4"
REF.
50' - 8"
A6-1.1
6' - 8 3/4"
2B
AC-1
66' - 9 1/4"
S&R
L.T.
3' - 8 1/4"
11' - 10"
205
N 06
05
GFI
208
4' - 3 1/4"
FD
4"
7' - 9"
0"
R1
5' -
LAUNDRY /
MUDROOM
8' - 7 3/4"
BEDROOM 3
FURNACE INTAKE
AC-1
3' - 7 3/4"
4' - 9 1/4"
1B
AC-1
7' - 6"
7' - 9"
6 3/4"
11 1/2"
FURNACE
EXHAUSTS
19' - 5"
B 02
02
5' - 1 1/2"
1' - 2 1/2"
DRYER VENTS
GFI
36' - 8 1/2"
216
17R @ 6.70"
16T @ 11"
1B
6' - 3 1/4"
STAIRS #2
AC-1
7' - 11 1/2"
4' - 3 1/2"
2
A6-1.4
4"
BATHROOM
EXHAUSTS
EF-3 KITCHEN
HOOD EXHAUST
3' - 8 3/4"
DN
7' - 10 3/4"
8"
3' - 1 1/2"
3A
17R @ 6.70"
16T @ 11"
A6-1.3
7' - 5"
8' - 1 1/4"
H.P.
3' - 10 3/4"
11 1/2"
A.1
4 3/4"
A.1
12' - 10 1/2"
11
1' - 3"
11 3/4"
4"
42" HT ALUMINUM
RAILING WITH
TEMPERED
GLASS PANELS
36" HT ALUMINUM
PANEL RAILING
A6-1.1
7' - 1 1/2"
1' - 6"
9' - 2"
5' - 10 1/2"
1' - 6"
5' - 6"
17' - 8"
8"
7' - 1"
14' - 2 1/2"
15' - 6 3/4"
39' - 1 1/4"
1
10.26.16
8"
DRAWN BY:
ROOF PLAN
A2-1.2
A2-1.2
FZM
AS NOTED
DESCRIPTION:
TYPICAL FLOOR
AND ROOF PLANS
A5-1.1
2
SHEET NO.
A2-1.2
NEW PARAPET
40' - 0"
ALUMINUM
CLAD ROOF
ROOF
38' - 6"
2 T
2" LIMESTONE
WINDOW SILL
4th FLOOR
29' - 0"
2 T
2" LIMESTONE
WINDOW SILL
3rd FLOOR
19' - 6"
2nd FLOOR CLG
18' - 2"
PROJECT #
1634
DATE:
09.29.16
2 T
2" REVEAL
2nd FLOOR
10' - 0"
ALUMINUM CLAD
ENTRY CANOPY
1
2" LIMESTONE
WINDOW SILL
A.1 A
1
A5-1.1
NEW PARAPET
40' - 0"
ROOF
38' - 6"
4th FLOOR CLG
37' - 2"
PRE-FAB CORNICE
ALUMINUM
CLAD ROOF
10
HARDI PLANK
PANEL
SIDING
4th FLOOR
29' - 0"
3rd FLOOR CLG
27' - 8"
10
TYPICAL BALCONY
POLISHED STEEL FASCIA
WOOD VENEER SOFFIT
2" LIMESTONE SILL
SOUTH ELEVATION
SCALE: 1/4" = 1'-0"
3rd FLOOR
19' - 6"
2nd FLOOR CLG
18' - 2"
10
1
42" HT. ALUMINUM
RAILING WITH TEMPERED
GLASS PANELS
2nd FLOOR
10' - 0"
ALUMINUM CLAD
ENTRY CANOPY
2
A5-1.1
EAST ELEVATION
SCALE: 1/4" = 1'-0"
10.26.16
DRAWN BY:
1st FLOOR
6"
GRADE
0"
SCALE:
AS NOTED
DESCRIPTION:
SHEET NO.
A5-1.1
4
5' - 11"
6' - 0"
3' - 0"
6' - 0"
3' - 0"
3' - 0"
3' - 0"
3' - 0"
6' - 0"
2 1/2"
ROOF
38' - 6"
4th FLOOR CLG
37' - 2"
7' - 0"
(2) CASEMENT
(2) AWNING
CASEMENT
AWNING
1
HARDI PLANK
PANEL SIDING
2nd FLOOR
3rd FLOOR
4th FLOOR
4" BRICK VENEER
6' - 0"
2 1/2"
3' - 0"
3' - 0"
3' - 0"
4th FLOOR
29' - 0"
3' - 0"
9' - 7"
FRENCH DOOR
(TEMPERED)
CASEMENT
(2) CASEMENT
STOREFRONT
(TEMPERED)
(2) CASEMENT
EMERGENCY ESCAPE
WINDOW SILL = 38"
CLEAR OPENING = 7.5 S.F.
CLEAR HEIGHT 42 7/8"
CLEAR WIDTH = 25 1/4"
WINDOW SCHEDULE
1
3rd FLOOR
19' - 6"
1ST FLOOR
CASEMENT
EMERGENCY ESCAPE
WINDOW SILL = 38"
CLEAR OPENING = 7.5 S.F.
CLEAR HEIGHT 42 7/8"
CLEAR WIDTH = 25 1/4"
11 T
1
7' - 0"
3' - 2"
7' - 0"
6' - 11 1/2"
4' - 0"
2 1/2"
6' - 9 1/2"
6' - 7"
4' - 0"
2 1/2"
2 1/2"
7' - 0"
7' - 0"
4' - 0"
(2) CASEMENT
(2) TRANSOM
2' - 3 1/2"
NEW PARAPET
40' - 0"
2 PANEL ALUMINUM
PATIO DOOR
2' - 0"
3' - 0"
3' - 0"
6' - 9 1/2"
T
7' - 0"
5' - 11"
3' - 0"
4' - 0"
2' - 6"
2 1/2"
3' - 0"
10
3' - 2"
3' - 0"
11
7' - 0"
2' - 11 1/2"
2' - 0"
7' - 0"
6' - 11 1/2"
4' - 0"
PREFAB CORNICE
11 T
PROJECT #
1634
DATE:
09.29.16
ALUMINUM CLAD
ENTRY CANOPY
2nd FLOOR
10' - 0"
1st FLOOR
6"
GRADE
0"
ALUMINUM
CLAD ROOF
PRE-FAB CORNICE
NEW PARAPET
40' - 0"
ROOF
38' - 6"
4th FLOOR CLG
37' - 2"
HARDI PLANK PANEL SIDING
3
6
1
2" LIMESTONE
WINDOW SILL
TYPICAL BALCONY
POLISHED STEEL FASCIA
WOOD VENEER SOFFIT
7 T
1
4th FLOOR
29' - 0"
3rd FLOOR CLG
27' - 8"
6
8
8
7 T
A5-1.2
NORTH ELEVATION
SCALE: 1/4" = 1'-0"
A A.1
2" REVEAL
1
3rd FLOOR
19' - 6"
7 T
1
2nd FLOOR
10' - 0"
ALUMINUM CLAD
ENTRY CANOPY
10.26.16
DRAWN BY:
SCALE:
AS NOTED
DESCRIPTION:
2
A5-1.2
WEST ELEVATION
SCALE: 1/4" = 1'-0"
1st FLOOR
6"
GRADE
0"
SHEET NO.
A5-1.2
A5-1.3
8
A5-1.3
8
A5-1.3
A5-1.3
A5-1.3
9' - 6"
9' - 6"
19' - 0"
A5-1.3
B 02
02
16'-0"x8'-0"
GARAGE DOOR
A5-1.3
1'-0"
40 YR ARCHITECTURAL ASPHALT
SHINGLES
6"
1
A5-1.3
1'-0"
1'-0"
6"
6"
HARDIE PLANK
PANEL SIDING
HARDIE PLANK
PANEL SIDING
5
1' - 4 1/2"
GRADE
0"
WINDOW HEADER
- SEE STRUCTURAL DRAWINGS
9' - 0 1/2"
1'-0"
40 YR ARCHITECTURAL ASPHALT
SHINGLES
GRADE
0"
4' - 0"
A5-1.3
6"
A5-1.3
1'-0"
1'-0"
40 YR ARCHITECTURAL ASPHALT
SHINGLES
6"
1'-0"
6"
6"
14' - 11"
3' - 8"
BOTTOM OF FASCIA
9' - 6"
HARDIE PLANK
PANEL SIDING
1" REVEAL - TYP.
BOTTOM OF FASCIA
9' - 6"
HARDIE PLANK
PANEL SIDING
5
10.26.16
DRAWN BY:
4"
GRADE
0"
A5-1.3
6"
A5-1.3
40 YR ARCHITECTURAL ASPHALT
SHINGLES
1' - 0"
A5-1.3
1' - 8"
09.29.16
TO HOUSE PANEL
BOTTOM OF FASCIA
9' - 6"
1'-0"
DATE:
A5-1.3
1634
9' - 6"
19' - 0"
PROJECT #
1' - 6"
3' - 0"
9' - 6"
A5-1.3
18' - 1"
19' - 0"
16' - 0"
1' - 6"
GFI
2x10's ROOF
RAFTERS @ 16" O.C.
6" / 1'-0"
1' - 6"
1' - 8"
3' - 4"
DOWN
SPOUT
1' - 4"
2x10's ROOF
RAFTERS @ 16" O.C.
16' - 0"
2x10's ROOF
RAFTERS @ 16" O.C.
A5-1.3 7
1' - 0"
A5-1.3 7
35' - 1 1/4"
6" / 1'-0"
36' - 0"
1' - 0"
36' - 0"
33' - 0"
16' - 0"
31' - 4"
6" / 1'-0"
16'-0"x8'-0"
GARAGE DOOR
1' - 8"
GFI
1' - 8"
2x10's ROOF
RAFTERS @ 16" O.C.
GFI
16' - 0"
DOWN
SPOUT
6" / 1'-0"
1' - 8"
1' - 6"
7
A5-1.3
GRADE
0"
6
A5-1.3
SCALE:
AS NOTED
DESCRIPTION:
GARAGE FLOOR
PLANS AND ELEVS
SHEET NO.
A5-1.3
NEW PARAPET
40' - 0"
ROOF
38' - 6"
1' - 2 1/4"
4' - 0"
3' - 0"
1' - 2 1/4"
40' - 0"
2nd FLOOR
10' - 0"
5/4" DECKING
1' - 2 1/4"
1' - 2 1/4"
9"
1' - 0"
9"
T/ FOOTING
-2' - 6"
1st FLOOR
6"
GRADE
0"
1 1/2" X 3' DEEP RIGID INSULATION
AROUND PERIMETER OF
FOUNDATION WITH PROTECTIVE
COVERING TO EXTEND 6" MIN
BELOW GRADE
4' - 0"
4' - 0"
1st FLOOR
6"
GRADE
0"
TYPICAL CONC.
SLAB
5" CONC. SLAB
W/6"x6"/ W2.1xW2.1
REINF. W/ 2" RIGID
INSUL (R-10) ON 5"
CA7 GRAVEL FILL ON
JETTED GROUND
TYPICAL CONC.
SLAB
5" CONC. SLAB
W/6"x6"/ W2.1xW2.1
REINF. W/ 2" RIGID
INSUL (R-10) ON 5"
CA7 GRAVEL FILL ON
JETTED GROUND
4
S-1
9"
1' - 0"
T/ FOOTING
-2' - 6"
2' - 6"
9"
2' - 6"
T/ FOOTING
-2' - 6"
10.26.16
DRAWN BY:
A6-1.1
2
A6-1.1
SECTION AT BALCONY
SCALE: 1/2" = 1'-0"
1
A6-1.1
AS NOTED
DESCRIPTION:
WALL SECTIONS
SHEET NO.
7' - 0"
1' - 2 1/4"
09.29.16
TYPICAL FLOOR
CONSTRUCTION 3/4" T & G SUB-FLOOR
G & N TO FLOOR
JOIST PER FRAMING
PLAN R-38 BATT
INSULATION
5/8" GYP DRYWAL
DATE:
1634
7' - 0"
40' - 0"
PROJECT #
1' - 4"
8' - 2 1/4"
1' - 2 1/4"
1' - 2 1/4"
2' - 6"
TYPICAL FLOOR
CONSTRUCTION 3/4" T & G SUB-FLOOR
G & N TO FLOOR
JOIST PER FRAMING
PLAN R-38 BATT
INSULATION
5/8" GYP DRYWAL
1' - 0"
TYPICAL FLOOR
CONSTRUCTION 3/4" T & G SUB-FLOOR
G & N TO FLOOR
JOIST PER FRAMING
PLAN R-38 BATT
INSULATION
5/8" GYP DRYWAL
3' - 0"
TYPICAL CONC.
SLAB
5" CONC. SLAB
W/6"x6"/ W2.1xW2.1
REINF. W/ 2" RIGID
INSUL (R-10) ON 5"
CA7 GRAVEL FILL ON
JETTED GROUND
3' - 0"
7' - 0"
1' - 2 1/4"
1' - 4"
TYPICAL FLOOR
CONSTRUCTION 3/4" T & G SUB-FLOOR
G & N TO FLOOR
JOIST PER FRAMING
PLAN R-38 BATT
INSULATION
5/8" GYP DRYWAL
8' - 2 1/4"
1' - 4"
TYPICAL FLOOR
CONSTRUCTION 3/4" T & G SUB-FLOOR
G & N TO FLOOR
JOIST PER FRAMING
PLAN R-38 BATT
INSULATION
5/8" GYP DRYWAL
8' - 2 1/4"
1' - 2 1/4"
7' - 0"
1' - 4"
1' - 4"
8' - 2 1/4"
TYPICAL FLOOR
CONSTRUCTION 3/4" T & G SUB-FLOOR
G & N TO FLOOR
JOIST PER FRAMING
PLAN R-38 BATT
INSULATION
5/8" GYP DRYWAL
3rd FLOOR
19' - 6"
2' - 6"
TYPICAL FLOOR
CONSTRUCTION 3/4" T & G SUB-FLOOR
G & N TO FLOOR
JOIST PER FRAMING
PLAN R-38 BATT
INSULATION
5/8" GYP DRYWAL
8' - 2 1/4"
1' - 2 1/4"
7' - 0"
8' - 2 1/4"
7' - 0"
1' - 4"
TYPICAL FLOOR
CONSTRUCTION 3/4" T & G SUB-FLOOR
G & N TO FLOOR
JOIST PER FRAMING
PLAN R-38 BATT
INSULATION
5/8" GYP DRYWAL
1' - 4"
1' - 0"
TYPICAL FLOOR
CONSTRUCTION 3/4" T & G SUB-FLOOR
G & N TO FLOOR
JOIST PER FRAMING
PLAN R-38 BATT
INSULATION
5/8" GYP DRYWAL
8' - 2 1/4"
8' - 2 1/4"
7' - 0"
8' - 2 1/4"
8' - 2 1/4"
1' - 2 1/4"
NEW PARAPET
40' - 0"
7' - 0"
7' - 0"
1' - 2 1/4"
ROOF
38' - 6"
1' - 4"
NEW PARAPET
40' - 0"
A.1 A
8' - 2 1/4"
1' - 4"
8' - 2 1/4"
A6-1.1
A.1 A
NEW PARAPET
40' - 0"
ROOF
38' - 6"
4th FLOOR CLG
37' - 2"
UNIT #4
4th FLOOR
29' - 0"
3rd FLOOR CLG
27' - 8"
UNIT #3
3rd FLOOR
19' - 6"
2nd FLOOR CLG
18' - 2"
STAIRS #1
UNIT #2
PROJECT #
1634
DATE:
09.29.16
2nd FLOOR
10' - 0"
1st FLOOR CLG
8' - 8"
1st FLOOR
6"
GRADE
0"
T/ FOOTING
-2' - 6"
NEW PARAPET
40' - 0"
UNIT 4
4th FLOOR
29' - 0"
3rd FLOOR CLG
27' - 8"
UNIT 3
3rd FLOOR
19' - 6"
A6-1.2
ROOF
38' - 6"
UNIT #1
UNIT 2
STAIRS #1
2nd FLOOR
10' - 0"
1st FLOOR CLG
8' - 8"
UNIT 1
10.26.16
DRAWN BY:
1st FLOOR
6"
GRADE
0"
T/ FOOTING
-2' - 6"
2
A6-1.2
AS NOTED
DESCRIPTION:
BUILDING
SECTIONS
SHEET NO.
A6-1.2
NEW PARAPET
40' - 0"
NEW PARAPET
40' - 0"
ROOF
38' - 6"
4th FLOOR CLG
37' - 2"
ROOF
38' - 6"
4th FLOOR CLG
37' - 2"
SD
1' - 0"
1' - 11"
5' - 3 1/4"
5' - 3 1/4"
1' - 0"
DN
3' - 5 1/2"
3' - 6"
3' - 8"
PROJECT #
1634
DATE:
09.29.16
1' - 11"
9 R @ 6.70" =
5' - 0 1/4"
1' - 0"
2nd FLOOR
10' - 0"
8 R @ 6.70" =
4' - 5 3/4"
9 R @ 6.70" =
5' - 0 1/4"
2nd FLOOR
10' - 0"
2' - 10"
9 R @ 6.70" =
5' - 0 1/4"
2' - 10"
8 R @ 6.70" =
4' - 5 3/4"
3' - 6"
2' - 10"
1' - 0"
3' - 6"
STAIR #2 SECTION
1' - 11"
3' - 8"
1st FLOOR
6"
GRADE
0"
NOTE:
PROVIDE 5/8" TO THE
UNDERSIDE OF STAIRS
1
A6-1.3
STAIR #1 SECTION
SCALE: 1/4" = 1'-0"
1' - 0"
3' - 5 1/2"
3' - 8"
3' - 8"
1' - 11"
1' - 0"
3' - 5 1/2"
3' - 8"
HANDRAIL
17R @ 6.70"
HANDRAIL
HANDRAIL
17R @ 6.70"
HANDRAIL
UP
1' - 11"
1' - 0"
3rd FLOOR
19' - 6"
3' - 4"
NOTE:
PROVIDE 5/8" TO THE
UNDERSIDE OF STAIRS
1' - 1 1/2"
1' - 11"
3rd FLOOR
19' - 6"
1st FLOOR
6"
GRADE
0"
3' - 5 1/2"
1' - 0"
2' - 10"
1' - 11"
A6-1.3
DN
ROOF ACCESS
LADDER
2' - 10"
2' - 10"
9 R @ 6.70" =
5' - 0 1/4"
8 R @ 6.70" =
4' - 5 3/4"
9 R @ 6.70" =
5' - 0 1/4"
ROOF ACCESS
HATCH 36" x 30"
4th FLOOR
29' - 0"
A6-1.3
4th FLOOR
29' - 0"
1' - 11"
1' - 0"
A6-1.3
1' - 0"
9 R @ 6.70" =
5' - 0 1/4"
215
8 R @ 6.70" =
4' - 5 3/4"
STAIRS #1
8 R @ 6.70" =
4' - 5 3/4"
1' - 11"
HANDRAIL
1' - 0"
3' - 8"
1' - 11"
3' - 8"
1' - 11"
3' - 5 1/2"
HANDRAIL
3' - 5 1/2"
17R @ 6.70"
3' - 5 1/2"
1' - 0"
3' - 5 1/2"
UP
17R @ 6.70"
17R @ 6.70"
HANDRAIL
UP
1' - 11"
2' - 10"
6' - 0 1/4"
1' - 11"
DN
HANDRAIL
1' - 0"
5' - 3 1/4"
SD
STAIRS #1
STAIRS #1
415
315
10.26.16
DRAWN BY:
6
A6-1.3
5
A6-1.3
SCALE:
AS NOTED
DESCRIPTION:
STAIR SECTIONS
SHEET NO.
A6-1.3
A.1
A.1
1' - 11"
HANDRAIL
1' - 0"
1' - 11"
17R @ 6.70"
9' - 7"
3' - 10"
HANDRAIL
DN
STAIRS #2
STAIRS #2
216
11' - 7 1/2"
11' - 7 1/2"
6' - 5"
3' - 7 1/4"
7 T @ 11" = 6' - 5"
115
5' - 3 3/4"
5' - 2 1/2"
17R @ 6.70"
1' - 0"
HANDRAIL
A6-1.4
1
A6-1.4
2
A
A.1
A.1
1' - 11"
1' - 0"
3' - 10"
STAIRS #2
3' - 9 1/2"
HANDRAIL
3' - 9 1/2"
416
HANDRAIL
1' - 0"
4' - 4 3/4"
17R @ 6.70"
DN
DN
STAIRS # 2
316
4' - 4 3/4"
17R @ 6.70"
3' - 8"
UP
1' - 0"
4
A6-1.4
5' - 3 3/4"
17R @ 6.70"
42" GUARDRAIL
09.29.16
HANDRAIL
1' - 11"
DATE:
1' - 11"
1634
1' - 11"
HANDRAIL
3
A6-1.4
10.26.16
DRAWN BY:
1' - 11"
PROJECT #
1' - 0"
UP
UP
3' - 8"
17R @ 6.70"
AS NOTED
DESCRIPTION:
PARTIAL STAIR
PLANS
SHEET NO.
A6-1.4
HEAD
HEAD
PLAN
PLAN
PLAN
(2) 5/8" GYP. BOARD
EA. SD. (FIRECODE CORE)
SOUND ATTENUATION
BLANKET
3/8" CONT. SEALANT
EACH SIDE
BASE
TYPE (#)
BRICK VENEER
WOOD STUD
BASE
STUD
SIZE
2x4
2x6
2x8
STUD
SPACING
16" OC
16" OC
16" OC
FIRE RATING /
TEST NO.
2 HR / U301
2 HR / U301
2 HR / U301
WALL
THK
6"
8"
10"
DTD.
NO.
A
B
STUD
SIZE
2x4
2x6
STUD
SPACING
24" OC
24" OC
FIRE RATING /
TEST NO.
1 HR / U309
1 HR / U309
01
02
03
04
05
06
07
08
09
10
WIDTH
HEIGHT
3'-0"
3'-0"
2'-10"
3'-0"
2'-8"
(2) 3'-0"
(2) 2'-6"
2'-6"
2'-4"
3'-0"
ELEV
7'-0"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
7'-0"
MATERIAL
B
A
A
A
A
C
C
A
A
D
METAL
WD/SC
WD/HC
WD/HC
WD/HC
WD/HC
WD/HC
WD/HC
WD/HC
METAL
FINISH
MATERIAL
METAL/HM
WD
WD
WD
WD
WD
WD
WD
WD
METAL/HM
PTD
PTD
PTD
PTD
PTD
PTD
PTD
PTD
FINISH
DETAILS
REMARKS
PTD
PTD
PTD
PTD
PTD
PTD
PTD
PTD
BASE
DTD.
NO.
A
B
C
FRAME
SET (#)
WALL
THK
4 3/4"
6 3/4"
DTD.
NO.
A
STUD
SIZE
2x6
STUD
FIRE RATING /
TEST NO.
24" OC
WALL
THK
11 1/4"
01
02
03
04
05
06
HINGES
LOCKSET
KNOB/LEVER
FINISH
LEVER W/PANIC
LEVER
LEVER
LEVER
PR KNOB - DUMMY
KNURLED LEVER
CLOSER STOP
CHROME - SATIN
CHROME - SATIN
CHROME - SATIN
CHROME - SATIN
CHROME - SATIN
CHROME - SATIN
YES
YES
NO
NO
NO
YES
WALL
WALL
WALL
WALL
WALL
WEATHERSTRIPPING
REMARKS
YES
NO
NO
NO
NO
YES
NOTE: ALL DOORS LEADING INTO HAZARDOUS ROOMS OR SPACES TO HAVE KNURLED HARDWARE.
PARTITION DETAIL 2 HR
1 1/2" = 1'-0"
3
EXTERIOR WALL CAPPING
DOOR HARDWARE TO BE REVIEWED BY ARCHITECT, OWNER AND GENERAL CONTRACTOR BEFORE ORDERING.
PROJECT #
1634
DATE:
09.29.16
HEAD
HEAD
HEAD
PLAN
PLAN
2x6 WOOD STUDS, TYP.
CONTRACTOR TO USE THE ARCHITECT'S DOOR TYPE PLAN DESIGNATION IN ADDITION TO THE ROOM NUMBER
ON ALL SHOP DRAWING SCHEDULE SUBMITTALS.
RIGID INSULATION
PROVIDE IDO LEVERS IN ALL HC ROOMS WHERE FLUSH MOUNTS ARE TYP.
GLAZING AT LABELED DOORS TO BE FIRE-RESISTIVE, PROVIDE SAFETY GLAZING AT ALL NON-RATED DOORS.
PLAN
2 X4 WOOD STUDS
2 X4 WOOD STUDS
DOOR DESCRIPTION
2 X2 WOOD STUDS
RIGID INSULATION
2 LAYERS 5/8" GYP. BOARD
GROUT @ REINFORCED
CELLS
BASE
3/8" CONT. SEALANT
GROUT @ REINFORCED
CELLS
BASE
DOOR DESIGNATION
STUD
SPACING
24" OC
FIRE RATING /
TEST NO.
2 HR / U349
WALL
THK
8"
DTD.
NO.
A
B
CMU
THK
6" CMU / 2X2
8" CMU / 2X2
24" OC
24" OC
FIRE RATING /
TEST NO.
2 HR / U906
2 HR / U906
WALL
THK
14 1/8"
16 1/8"
DTD.
NO.
A
B
CMU
THK
6" CMU / 2X2
8" CMU / 2X2
24" OC
24" OC
FIRE RATING /
TEST NO.
2 HR / U906
2 HR / U906
WALL
THK
11 1/2"
13 1/2"
A 01
01
DOOR HARDWARE SET
10.26.16
DRAWN BY:
STUD
SIZE
2x6
DOOR NUMBER
DTD.
NO.
A
3 HR. (CLASS A)
90 MIN. (CLASS B)
60 MIN. (CLASS B)
45 MIN. (CLASS C)
20 MIN.
NON RATED
FIRE RATING
A
B
C
D
E
N
BASE
DOOR NOTES
AS NOTED
DESCRIPTION:
SHEET NO.
A8-1.1
39' - 4"
4' - 8"
16' - 1"
18' - 7"
PER PLAN
1' - 6"
8' - 4"
3
21' - 5 3/4"
17' - 10 1/2"
S-1
S-1
1' - 0"
4' - 3"
3
1' - 0"
8' - 2"
2' - 6"
4' - 0"
2' - 6"
1634
DATE:
09.29.16
FOOTING DETAIL
S-1
4' - 0"
2- #4 BARS
CONTINUOUS
6"
6"
6"
L1
1' - 0"
3' - 6"
6"
50' - 8"
1' - 0"
S-1
5' - 11"
2' - 6"
L2
2' - 6"
1' - 6"
L1
16' - 10 1/2"
2' - 6"
UP
1' - 8"
1' - 6"
1' - 6"
4' - 0"
1' - 8"
4' - 0"
HSS 4X4X3/8 COLUMN
2' - 6"
21' - 5"
MARK
17' - 11"
L1
7' - 1 1/2"
L1
SIZE OF HEADER NO STORY ABOVE ONE STORY ABOVE TRIMMERS/ JACK STUDS
H7
10'-0"
8'-0"
3 1/2" X 11 7/8"*
14'-0"
10'-0"
12'-0"
3 1/2" X 14"*
16'-3"
3 1/2" X 18"*
18'-3"
16'-3"
5 1/4" X 14"*
18'-3"
14'-0"
7" X 14"*
18'-3"
16'-3"
C
L1
6"
9' - 2"
5' - 10 1/2"
1' - 6"
L1
5' - 3"
17' - 4 3/4"
23' - 3 1/4"
LINTEL SCHEDULE
SECTION SIZE
2' - 6"
2' - 0"
L1
NOTE:
BASED ON THE SIZING TABLES PROVIDED BY TRUS JOIST IN HEADER AND COLUMN SPECIFIER'S GUIDE
PARAMETERS USED: ROOF LOAD: SNOW AREA 115%, 40LL + 15DL, HOUSE WIDTH: 24'
* DENOTES A SPECIFIC MICROLLAM SIZE
MARK
L1
2' - 6"
H6
3 1/2" X 9 1/4"*
6"
H5
2' - 0"
H4
<8'-0"
6"
H3
<8'-0"
6' - 7"
H2
5"
H1
2' - 6"
L2
7' - 0"
1st FLOOR
6"
1' - 6 3/4"
7' - 6"
9' - 10 1/4"
L2
67' - 0"
4
S-1
PROJECT #
T/ FOOTING
-2' - 6"
L1
L1
MIN BEARING
PREASURE OF
3000 PSF
REQUIRED. TO BE
VERIFIED BY
GEOTECHNICAL
ENGINEER
2
#4 @ 12" O.C.
1' - 6 3/4"
36' - 8 1/2"
2'-6"
UP
24' - 4 1/2"
#4 @ 12" O.C.
2'-6"
1st FLOOR
6"
1' - 8"
17' - 4 3/4"
GRADE
0"
L1
2' - 6"
#4 @ 18" O.C.
EITHER SIDE
1st FLOOR
6"
4- #8 BARS @12"
O.C. EACH WAY
2' - 6"
1' - 0"
(4) #4 CONTINUOUS
1' - 8"
1/4"
1-1/4" PLATE
#4 @ 18" O.C.
1' - 0"
A.1
L1
L1
2' - 6"
SLIPCE LENGHT
L2
2' - 6"
L1
16' - 0 3/4"
39' - 4"
MATERIAL
L1
L2
L3
L4
2-1 3/4" x 11 1/4" LVL + 6" X 3 1/2" X 3/8" A-36 GRADE B CARBON STEEL
NOTE:
*
LONG LEG OF THE ANGLE SHALL BE PLACED IN THE VERTICAL POSITION
STEEL ANGLES TO HAVE MIN. 6" BEARING, EACH SIDE
**
FOR CONTINUOUS SPANS, ANCHOR STEEL ANGLES TO DOUBLE STUD WALL FRAMING
W/(2) 7/16" X 4" LAG SCREWS @ 16" O/C
***
MAX HEIGHT OF MASONRY VENEER ABOVE CONTINUOUS ANGLE NOT TO EXCEED 12'-8"
1
S-1
METAL CONNECTORS
ITEM
SST MODEL #
USP MODEL #
GAGE
INSTALLATION HARDWARE
LUS2xxZ or SS
JUS2xxTZ or SS
18
LUS2xx-2Z or SS
JUS2xx-2TZ or SS
18
METAL ANGLE 1
L90Z
AC9 TZ
16
10 - 10d, 5 EA LEG
METAL ANGLE 2
A23Z
A3 TZ
18
METAL ANGLE 3
TA9Z or KT
SCA9 TZ
12
CBSQ66-SDS2 HDG
CBSQ66-SDS2 TZ
12
SCALE:
AS NOTED
ABW66Z
12
12 - 10d
PBS44A HDG
WAS44 TZ
12
DESCRIPTION:
METAL STRAP
MSTA12Z or SS
MSTA12TZ or SS
18
10 - 10d
CPS 4
CPB 44
4 - 10d
FOUNDATION PLAN
FIRST FLOOR
FRAMING
10.26.16
DRAWN BY:
SHEET NO.
S-1
38' - 9 1/2"
4' - 7 1/2"
39' - 4"
16' - 1 1/2"
18' - 0 1/2"
4' - 10 3/4"
15' - 10 1/4"
18' - 7"
H1
L4
L3
H1
1' - 3"
A
A.1
8' - 1 1/4"
8' - 4 1/2"
DN
H1
H1
H1
DN
L3
UP
L3
A.1
H1
11 1/2"
H1
H1
3' - 6"
2-2 x 10's
H1
L3
L4
H1
1634
DATE:
09.29.16
36' - 10 1/2"
35' - 10 3/4"
3 1/2" x 11 1/4"
2.0E PSL
PROJECT #
L4
66' - 9 1/4"
DN
H1
H2
L3
L4
2x12 LEDGER
23' - 10 3/4"
H1
H1
H1
6' - 0"
L3
L3
DN
H1
H1
50' - 8"
6' - 8 1/4"
H1
66' - 5 3/4"
50' - 1 1/2"
H1
2 x 12 LEDGER
L3
H1
D
2-2x12's
H1
2-2 x 12's
6' - 9 1/4"
2-2x12's
7' - 0 1/2"
H1
H1
2-2 x 12's
H1
H1
2x12 FLOOR JOIST @ 16" O.C.
10.26.16
2
S-2
DRAWN BY:
FZM
SCALE:
AS NOTED
DESCRIPTION:
SHEET NO.
S-2
MECHANICAL NOTES
6)
7)
8)
9)
10)
11)
STAIRS #2
4X10 S/A
110 CFM
FD
BEDROOM 3
208
15)
209
4X10 S/A
50 CFM
17)
18)
19)
SUCTION AND LIQUID LINE SETS OVER 79FT MAY REQUIRE A SIZE UP.
FIELD VERIFY DISTANCE AND MANUFACTURER RECOMMENDED
INSTALLATION REQUIREMENTS.
WIC
108
HALL
2)
3)
4)
EF-2
REF.
4X10 S/A
50 CFM
206
6)
7)
MASTER
BATHROOM
DW
REF.
VENT THRU ROOF
KITCHEN
MECH CLOSET
KITCHEN
203
211
103
VENT THRU
ROOF
WH
MECH CLOSET
110
106
207
4X10
EF-1S/A
50 CFM
4X10 S/A
100 CFM
4X10 S/A
100 CFM
4X10 S/A
153 CFM
4x10 R/A
100 CFM
LIVING/ DINING
101
4x10 R/A
237 CFM
4x10 R/A
153 CFM
LIVING / DINING
STORAGE
STORAGE
201
FD
113
214
4X10 S/A
126 CFM
4x10 R/A
236 CFM
4x10 R/A
251 CFM
BEDROOM 2
4X10 S/A
125 CFM
4x10 R/A
128 CFM
104
4x10 R/A
106 CFM
BEDROOM 2
204
4X10 S/A
128 CFM
M1-1.1
09.29.16
BATH 2
4x10 R/A
100 CFM
4X10 S/A
158 CFM
DATE:
4X10 S/A
50 CFM
BATH 2
213
4X10 S/A
158 CFM
1634
105
F-1
EF-1
VESTIBULE
PROJECT #
FD
EF-3
4X10 S/A
50 CFM
EF-2
4X10 S/A
50 CFM
FD
WH
4x10 R/A
50 CFM
F-1
5)
109
117
MASTER
BATHROOM
HALL
SPRINKLER RM
210
4X10 S/A
157 CFM
1)
FD
116
4x10 R/A
110 CFM
4x10 R/A
152 CFM
4X10 S/A
61 CFM
WIC
4x10 R/A
50 CFM
16)
107
FD
4x10 R/A
183 CFM
205
14)
4X10 S/A
50 CFM
LAUNDRY /
MUDROOM
118
LAUNDRY /
MUDROOM
102
202
13)
MASTER
BEDROOM
115
4x10 R/A
50 CFM
MASTER
BEDROOM
EF-3
12)
STAIRS #2
216
4x10 R/A
50 CFM
4X10 S/A
51 CFM
4X10 S/A
50 CFM
5)
4X10 S/A
51 CFM
4X10 S/A
50 CFM
4)
4X10 S/A
61 CFM
3)
4X10 S/A
61 CFM
2)
DW
1)
4X10 S/A
106 CFM
1
M1-1.1
9)
10)
THE INSULATION INSTALLER SHALL SIGN, DATE, AND POST THE CERTIFICATE LISTING THE
PREDOMINANT INSULATION VALUE IN A CONSPICUOUS LOCATION IN THE ATTIC. BLOWN OR SPRAYED
ROOF/CEILING INSULATION THICKNESS SHALL BE INDENTIFIED IN WRITTEN INCHES, AFFIXED TO THE
TRUSS OR JOISTS EVERY 300 FEET FOR INSPECTION (R303.1.1.1 & R403.) THIS SHALL BE POSTED
PRIOR TO THE INSULATION INSPECTION."
CONTRACTOR SHALL POST ON THE ELECTRIC DISTRIBUTION PANEL A PERMANENT CERTIFICATE.
THE CERTIFICATE SHALL LIST THE PREDOMINANT INSULATION VALUE, EACH PIECE OF THE BUILDING
THERMAL ENVELOPE, R-VALUES OF INSULATION INSTALLED, U-FACTORS OF THE WINDOWS, RVALUES OF DUCTS IN UNCONDITIONED SPACES, AND TYPES AND EFFICIENCIES OF HEATING COOLING
AND WATER HEATING EQUIPMENT. (R303.1.1 & R401.3) THIS SHALL BE POSTED PRIOR TO THE
INSULATION INSPECTION."
THIS PROJECT MUST MEET ENERGY CODE REQUIREMENTS FOR CLIMATE ZONE 5.
10.26.16
DRAWN BY:
AS NOTED
DESCRIPTION:
SHEET NO.
M1-1.1
1
FURNACE SCHEDULE
MFG
MODEL
CFM
BTUH Input
F-1
RHEEM
RGGE-09EZCMS
1195
90000
83160
Motor (Hp)
Motor (Amps)
12
COMMENTS
A.1
H.P.
MARK
BTUH
Output
B
BATHROOM
EXHAUSTS
DRYER VENTS
1
R1
5' -
0"
A6-1.1
Level
COMMENTS
101
102
103
104
105
106
107
108
109
110
111
112
114
115
409 SF
250 SF
241 SF
172 SF
109 SF
48 SF
58 SF
41 SF
50 SF
25 SF
86 SF
0 SF
50 SF
113 SF
14321
8756
8449
6022
3801
1696
0
0
1751
0
3011
0
1741
3945
146
89
86
61
50
50
0
0
50
0
50
0
50
50
251
152
153
106
50
50
0
0
50
0
50
0
50
50
17436
10594
10645
7388
4583
2040
0
0
2457
0
2633
0
3208
4607
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
F-1
F-1
F-1
F-1
F-1
F-1
F-1
F-1
F-1
F-1
F-1
F-1
F-1
F-1
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
425 SF
263 SF
247 SF
183 SF
155 SF
112 SF
51 SF
58 SF
43 SF
63 SF
25 SF
0 SF
84 SF
61 SF
78 SF
120 SF
3623 SF
3623 SF
14891
9200
8636
6409
5429
3933
1772
0
0
2221
0
0
2950
0
2744
4213
115893
115893
152
94
88
65
55
50
50
0
0
50
0
0
50
0
50
50
1438
1438
301
183
172
111
128
50
50
0
0
50
0
0
50
0
50
50
2158
2158
16906
10271
9659
7163
6194
4444
1978
0
0
2382
0
0
3138
0
3079
4467
135272
135272
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
F-1
F-1
F-1
F-1
F-1
F-1
F-1
F-1
F-1
F-1
F-1
F-1
F-1
F-1
F-1
F-1
FURNACE INTAKE
FURNACE
EXHAUSTS
EF-3 KITCHEN
HOOD EXHAUST
AC-1
AC-1
45 DOWN
12"
AC-1
2 1/2"
1/2" AROUND 3 SIDES.
2'X2' WOOD.
ROOF ACCESS
HATCH
ROOFING
MATERIAL.
REFRIGERANT LINES TO CONDENSER.
CANTOUR BY ROOFING CONTRACTOR.
REFRIGERANT HOOD
NO TO SCALE
NO
AREA
101
102
103
104
105
106
107
108
109
110
111
113
114
115
116
117
118
409 SF
250 SF
241 SF
172 SF
109 SF
48 SF
58 SF
41 SF
50 SF
25 SF
86 SF
57 SF
50 SF
113 SF
25 SF
60 SF
84 SF
32.7 SF
20.0 SF
19.3 SF
13.8 SF
LIVING / DINING
201
MASTER BEDROOM
202
KITCHEN
203
BEDROOM 2
204
BEDROOM 3
205
MASTER BATHROOM
206
BATH 2
207
LAUNDRY / MUDROOM
208
WIC
209
HALL
210
MECH CLOSET
211
VESTIBULE
213
STORAGE
214
STAIRS #1
215
STAIRS #2
216
2nd FLOOR - 3rd and 4th FLOORS SIMILAR
425 SF
263 SF
247 SF
183 SF
155 SF
112 SF
51 SF
58 SF
43 SF
63 SF
25 SF
84 SF
61 SF
78 SF
120 SF
34.0 SF
21.0 SF
19.7 SF
14.7 SF
12.4 SF
STAIRS #1
STAIRS # 2
3rd FLOOR
78 SF
120 SF
LIVING/ DINING
MASTER BEDROOM
KITCHEN
BEDROOM 2
MASTER BATHROOM
BATH 2
LAUNDRY / MUDROOM
WIC
HALL
MECH CLOSET
LOBBY
STORAGE
STAIRS #1
STAIRS #2
ELECTRICAL RM
SPRINKLER RM
STORAGE
1st FLOOR
STAIRS #1
STAIRS #2
4th FLOOR
315
316
415
416
160 SF
120 SF
16.4 SF
10.0 SF
9.7 SF
6.9 SF
59.5 SF
50.4 SF
5.9 SF
33.6 SF
59.5 SF
56.4 SF
5.9 SF
33.6 SF
16.8 SF
2"
41.4 SF
51.8 SF
6.3 SF
35.2 SF
110
80
17.0 SF
10.5 SF
9.9 SF
7.3 SF
6.2 SF
2"
41.4 SF
50.3 SF
6.3 SF
35.2 SF
17.6 SF
110
80
ROOFING
MATERIAL
REMARKS
Level
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
3rd FLOOR
3rd FLOOR
4th FLOOR
4th FLOOR
EXHAUST HOOD
NO TO SCALE
CONDENSER.
H.P.
ROOM NAME
09.29.16
BIRD SCREEN
ACTUAL
EXH.
DATE:
BATHROOM
EXHAUSTS
ACTUAL
LIGHT
VENT
1634
AC-1
ORDINANCE REQ'D
LIGHT
VENT
EXH.
PROJECT #
METAL CAP.
ROOFING MATERIAL BY ROOFER.
BATT INSULATION
RUBBER
ISOLATION
GROMMET
ACTUAL CFM
GFI
REQ'D CFM
GFI
HEAT LOSS
LIVING / DINING
MASTER BEDROOM
KITCHEN
BEDROOM 2
BEDROOM 3
MASTER BATHROOM
BATH 2
LAUNDRY / MUDROOM
WIC
HALL
MECH CLOSET
BALCONY
VESTIBULE
STORAGE
STAIRS #1
STAIRS #2
AREA
GFI
1st FLOOR
LIVING/ DINING
MASTER BEDROOM
KITCHEN
BEDROOM 2
MASTER BATHROOM
BATH 2
LAUNDRY / MUDROOM
WIC
HALL
MECH CLOSET
LOBBY
TERRACE
STAIRS #1
STAIRS #2
2nd FLOOR - 3rd and 4th Similar
NO
GFI
ROOM NAME
CONDENSER ON
CURB DETAIL
NOT TO SCALE
D
2003 INTERNATIONAL MECHANICAL CODE SECTION 504.2:
PROHIBITS THE INSTALLATION OF A FIRE OR SMOKE
DAMPER IN THE DRYER EXHAUST DUCT SINCE HEAT OR
LINT COULD DAMAGE OR OBSTRUCT THE OPERATION OF
THE FIRE DAMPER. THEREFORE DUCTS CAN NOT
PENETRATE A FIRE-RESISTANCE RATED ASSEMBLY.
PROVIDE A MINIMUM 12
FT. CLEARANCE FROM
VENT HOOD DISCHARGE
TO ANY OUTSIDE AIR
INTAKE OPENING.
REMOVABLE HOOD
DESIGNED FOR ACCESS TO
DRYER CLEAN OUT
SEPERATE DRYER DUCTS TO
THE EXTERIOR.
ROOF
MAYTAG AUTOMATIC DRYER
INSULATION GUIDE
NUMBER
OF 90 DEGREE
TURNS
M1-1.2
ALL 26 GAUGE
5th FLOOR
4"
2- 1/2"
DRYER RISER 4" TYPICAL
36 FT
32 FT
28 FT
25 FT
23 FT
3rd FLOOR
10.26.16
2nd FLOOR
28 FT
24 FT
20 FT
17 FT
15 FT
DRAWN BY:
3rd FLOOR
3rd FLOOR
2nd FLOOR
2"
GALVANIZED SHEET
METAL CAP 1" LARGER
THAN CURB.
1/2" AROUND CLEARANCE
AROUND ALL SIDES
2" LIP TURNED DOWN
NOTE:
ALL FIRE DAMPERS TO COMPLY WITH THE
SPECIFIED U.L. DISIGN RATING AND 1993
BOCA NATIONAL BUILDING CODE.ALL ROUND
FIRE DAMPERS TO BE SPRING LOADED.
FZM
2nd FLOOR
NOTE:
ALL FIRE DAMPERS TO COMPLY WITH THE
SPECIFIED U.L. DISIGN RATING AND 1993 BOCA
NATIONAL BUILDING CODE.ALL ROUND FIRE
DAMPERS TO BE SPRING LOADED.
SCALE:
AS NOTED
DESCRIPTION:
SHEET NO.
M1-1.2
ELECTRICAL NOTES
1) ELECTRICAL SERVICE & PANEL to be 400 AMP.
STORAGE
LAUNDRY /
MUDROOM
118
107
TV
SD
ELECTRICAL SYMBOL
SMOKE DETECTOR
CO
42
GFI
WP
WEATHERPROOF EXTERIOR
RECEPTACLE
3
100 AMP
COMMON
HOUSE
PANEL
FD
XX
SD
600 AMP
MAIN
PANEL
ELECTRICAL RM
116
CO
GFI
42
HALL
MECH CLOSET
109
110
GFI
42
MASTER
BATHROOM
EF
09.29.16
117
GFI
42
DATE:
SPRINKLER RM
GFI
42
GFI
42
REF.
RECEPTACLE (DED. CIRCUIT)
REF - REFRIGERATOR
FURN - FURNACE
WH WATER HEATER
EJEC - EJECTOR PUMP
SUMP - SUMP PUMP
OV OVEN (220V)
HD KITCHEN HOOD
CK COOKTOP
108
1634
105
FD
R
WH
KITCHEN
VP
GFI
103
RECEPTACLE
xx INCHES A.F.F.
BATH 2
RECEPTACLE - CEILING
EM
THERMOSTAT
SD
RECESSED DOWNLIGHT
R - 5" DIA
RW - CLOSED LENS, WET LOC.
3
3
FLOURESCENT
CEILING FIXTURE
GFI
PH
DATA
TRACK LIGHTING
FD
DECOR.
PENDANT FIXTURE
LIVING/ DINING
TO FIXTURE
ABOVE
101
STORAGE
113
DECOR.
SURFACE MOUNTED W/ PULL
CHAIN
PC
TO COMMON
HOUSE PANEL
SWITCH
3 - THREE-WAY
D - DIMMER
FAN
SD
SD
CO
TV
LOW VOLTAGE
INTERNET TERMINAL (CAT 5)
DATA
EF
106
XX
SD
WIC
PROJECT #
GFI
DESCRIPTION
TO COMMON
HOUSE PANEL
MARK
17) ALL LOW VOLTAGE WIRING FOR THE DOORBELLS AND HVAC
MUST BE IN CONDUIT.
102
FAN
DATA
MASTER
BEDROOM
GFI
115
10) PROVIDE SPEAKERS & WIRING FOR THE FAMILY ROOM &
DINING ROOM.
STAIRS #2
GFI
PH
EM
DW
GFI
TO FIXTURE
ABOVE
GFI
42
39) HOT TUBS: RUN GREEN GROUND FROM PANEL TO HOT TUB
OUTLET. MUST HAVE DISCONNECT AND BE
GFCI
PROTECTED AND BE READILY ACCESSIBLE. USE GFCI
BREAKER OR FACELESS GFCI OUTSIDE HOT TUB.
GFI
42
TO COMMON
HOUSE PANEL
GFI
42
TV
3
J
3
FAN
GFI
LOW VOLTAGE
TELEPHONE OUTLET
PH
EF
BEDROOM 2
104
EXHAUST FAN
ELECTRICAL PANEL
ELECTRICAL METER
2
E1-1.1
10.26.16
DRAWN BY:
SCALE:
AS NOTED
DESCRIPTION:
FZM
SHEET NO.
E1-1.1
ELECTRICAL SYMBOL
MARK
BALCONY
RECESSED INCANDESCENT
OR FLOURESCENT
DESCRIPTION
SURFACE INCANDESCENT
SD
SMOKE DETECTOR
CO
SURFACE INCANDESCENT
OR FLOURESCENT
WP
5"
DUPLEX RECEPTACLE
WEATHERPROOF EXTERIOR
RECEPTACLE
FROM
FIXTURE
BELOW
STORAGE
AREA
TV
202
STAIRS #2
DATA
J
216
FAN
LAUNDRY /
MUDROOM
D
RECEPTACLE
xx INCHES A.F.F.
BEDROOM 3
208
205
XX
MASTER
BEDROOM
EM
XX
PH
FD
RECEPTACLE - CEILING
SD
THERMOSTAT
FAN
GFI
42
210
GFI
42
GFI
42
REF.
MASTER
BATHROOM
206
R
GFI
42
FD
SERVICE
203
GFI
3 X 500 MCM
GFI
KITCHEN
PP-1
TYPICAL UNIT
PANEL
LOW VOLTAGE
TV - CO-AXIAL
100 A
PROTECTION
BATH 2
EM
1 PHASE
42 CIRCUITS
LOW VOLTAGE
TELEPHONE OUTLET
SD VESTIBULE
213
TO COMMON
HOUSE PANEL
EXHAUST FAN
1" - 3 x #3 TWHN
EACH UNIT
ELECTRICAL PANEL
ELECTRICAL METER
LIVING / DINING
COMMON HOUSE
PANEL
201
PH
DATA
STAIRS #1
TV
1 PHASE
215
42 CIRCUITS
PP-M
2nd SUPPLEMENTAL
GROUND 1/2" EMT #6 CU
TWHN ATTACHED TO 2 x
5/8" GROUND ROD (6 FT
AWAY FROM 1st)
1st SUPPLEMENTAL
GROUND 1/2" EMT #6 CU
TWHN ATTACHED TO 2 x
5/8" GROUND ROD
600 A
TO WATER METER 1"
EMT #2/0 CU TWHN
ATTACHED TO 5/8"
GROUND ROD
STORAGE
TO FIXTURE
ABOVE
1 x 100A
COMMON
HOUSE METER
SD
CO
SD
PROTECTION
1 PHASE
214
42 CIRCUITS
m
3
J
FAN
3
EM
PP-2
100 A
PROTECTION
2 x 3" RIGID
500 MCM
EF
207
GFI
42
LOW VOLTAGE
INTERNET TERMINAL (CAT 5)
EF
VP
GFI
GFI
42
WH
GFI
42 DW
PH
GFI
42
GFI
42
3'-0"
DECOR.
SURFACE MOUNTED W/ PULL
CHAIN
DATA
CO
EF
DECOR.
PENDANT FIXTURE
TV
09.29.16
HALL
SD
BATHTUB
FAN
DATE:
SD
TRACK LIGHTING
1634
4
R
HANGING, CORD
CONNECTED, OR
PENDANT
FIXTURE IN THIS AREA
FLOURESCENT
CEILING FIXTURE
PC
PROJECT #
4
NO HANGING, CORD
CONNECTED, OR PENDANT
FIXTURE IN THIS AREA
RECESSED DOWNLIGHT
R - 5" DIA
RW - CLOSED LENS, WET LOC.
209
SWITCH
3 - THREE-WAY
D - DIMMER
R
WIC
WP
TO FIXTURE
ABOVE
8": FLOURESECENT
12" INCANDESCENT
STORAGE
AREA
42
GFI
12"
GFI
4 x 100A
RESIDENTIAL
METERS
BEDROOM 2
204
CONCRETE ENCASED
ELECTRODE
1
E1-1.2
10.26.16
DRAWN BY:
AS NOTED
DESCRIPTION:
TYPICAL FLOOR
ELECTRICAL PLAN
SHEET NO.
E1-1.2
A.1
A.1
STAIRS #2
MASTER
BEDROOM
216
202
STAIRS #2
115
B
D
MASTER
BEDROOM
102
STORAGE
2" V
2" W
P3, W3
118
LAUNDRY /
MUDROOM
208
FD
LAUNDRY /
MUDROOM
2" V
2" W
P3, W3
107
FD
2" W
2" W
2" W
2" W
WIC
PROJECT #
1634
DATE:
09.29.16
WIC
108
209
BEDROOM 3
FD
ELECTRICAL RM
210
2" W
SPRINKLER RM
2" W
4" V
4" W
211
2" W
117
4" V
4" W
MASTER
BATHROOM
MECH CLOSET
206
2" V
REF.
WH
203
2" W
P1,W1
2" W
2" V
2" W
2" V
2" W
WH
KITCHEN
DW
DW
KITCHEN
2" W
103
6" W
2" W
2" W
C.O.
BATH 2
4" V
4" W
207
2" W
2" V
P1,W1
4" W
C.O.
2" W
2" W
105
4" W
FD
2" V
2" V
MASTER
BATHROOM
110
REF.
2" W
FD
P2, W2
109
116
MECH CLOSET
HALL
2" V
P2, W2
HALL
4" V
4" W
2" W
2" V
2" V
2" W
BATH 2
2" W
P4, W4
106
P4, W4
2" W
LOBBY
213
111
LIVING / DINING
201
C.O.
LIVING/ DINING
101
2" V
2" W
FD
STORAGE
214
STORAGE
113
STAIRS #1
STAIRS #1
215
114
VESTIBULE
C.O.
205
BEDROOM 2
204
BEDROOM 2
D
2
P1-1.1
104
1
P1-1.1
10.26.16
DRAWN BY:
AS NOTED
DESCRIPTION:
SHEET NO.
P1-1.1
P1
4x5 UP
THRU
ROOF
ROOF
THE PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE AND FULLY
OPERATING SYSTEM FOR THE SOIL, WASTE, VENT, SEWER, DOMESTIC COLD WATER
AND NATURAL GAS SERVICES. THE CONTRACTOR SHALL EXTEND THESE
SERVICES
TO ALL OTHER FIXTURES SHOWN ON THE DRAWINGS AND PROVIDE ALL CONNECTORS,
UNIONS AND TRAPS REQUIRED FOR FINAL CONNECTION TO ALL EQUIPMENT, WHETHER
FURNISHED IN THE PLUMBING WORK OR SUPPLIED BY OTHER TRADES.
4"W
BATH 2
MSTR BATH
2"W
2"W
2"W
MSTR BATH
4"W
BATH 2
WC
MECH
2"W
2"W
2"W
2"W
2"W
MSTR BATH
16)
GREY
BOX
SINK
2"W
GREY
BOX
2"W
2"W
LAUNDRY
2"V
2"V
4"W
BATH 2
MSTR BATH
MECH
2"W
2"W
2"W
2"W
2"W
MSTR BATH
4"V
2"W
2"W
PROJECT #
1634
DATE:
09.29.16
2"W
2"W
LAUNDRY
4"V
2"V
GREY
BOX
2"V
2"V
SINK
2"V
GREY
BOX
2"V
2"V
LAV
LAV
WC
FD
2" W
4"V
2"V
SH
2ND FLOOR
2"V
TUB
4"V
2"V
SINK
1 1/2"V
2"V
2"V
2"V
4"V
4"W
BATH 2
4"W
MSTR BATH
WC
FD
MECH
SPRINKLER RM
2"W
2"W
2"W
MSTR BATH
2"W
2"W
STORAGE
2"W
LAUNDRY
4"V
2"W
2"V
GREY
BOX
2"V
2"V
SINK
2"V
GREY
BOX
2"V
1 1/2"V
2"V
FD
LAV
2"V
4"V
FD
2" W
1 1/2"V
2"V
SH
1ST FLOOR
2"V
TUB/SH
4"V
ALL FOOTING DRAIN TILE SHALL BE 6" PVC SUBSURFACE DRAIN PIPE SCHEDULE 40
W/ NYLON SOCK FILTER FABRIC- ASTM D3034, SPR 35
2"V
LAV
2"V
1 1/2"V
TUB
ALL FLOOR DRAINS MUST BE ACID AND RUST RESISTANT, AND SHALL BE CAST IRON
OR BRONZE.
LAV
4"W
2"W
KITCHEN
2"W
GRASE TRAP
6" SANITARY
6" W PVC
SAN
VENT
19)
ALL CLEAN-OUTS SHALL TERMINATE FLUSH WITH THE FINISH FLOOR OR WALL.
20)
21)
SLOPE ALL SANITARY LINES 1/4" PER FOOT OR AS SHOWN ON THE DRAWINGS.
3/4"
3/4"
3/4"
LAV
WC
WH-1
50 GAL
SH
1/2"
WC
3/4"
1/2"
1/2"
23)
24)
25)
26)
WATER PIPE SIZING SHALL MAINTAIN SERVICE SIZE TO FIRST BRANCH OR WATER
HEATER LOCATION
VENT STACK SHALL BE LOCATED A MINIMUM OF 10' FROM ANY FRESH INTAKE OR
ATTIC VENTILATION OPENINGS
BATH 2
AIR CHAMBER
3/4"
WH-1
50 GAL
SH
LAV
1/2"
KITCHEN
LAUNDRY
3/4"
1/2"
SH
LAV
1/2"
3/4"
TUB
3/4"
K SINK
1/2"
GREY
BOX
DW
1/2"
1/2"
1/2"
BATH 2
AIR CHAMBER
3/4"
MSTR BATH
3/4"
KITCHEN
LAUNDRY
3/4"
WH-1
50 GAL
SH
LAV
1/2"
LAV
WC
3/4"
1/2"
SH
LAV
1/2"
3/4"
TUB
3/4"
K SINK
1/2"
GREY
BOX
DW
1/2"
1/2"
1/2"
2ND FLOOR
3/4" WATER METER
BATH 2
MSTR BATH
KITCHEN
LAUNDRY
24"
AIR CHAMBER
24"
LAV
WC
1/2"
32)
1/2"
3RD FLOOR
1/2"
3/4"
WC
31)
1/2"
MSTR BATH
3/4"
WC
3/4"
GREY
BOX
DW
24"
28)
3/4"
K SINK
4TH FLOOR
24"
DRAIN TILE SHALL BE LOOPED , COVERED WITH FABRIQUE AND 12" STONE.
1/2"
TUB
1/2"
1/2"
27)
SH
LAV
24"
24"
22)
LAV
P1-1.2
24"
18)
PROVIDE AND INSTALL SHUT-OFF VALVES IN THE SUPPLY PIPING FOR EVERY
FIXTURE.
24"
17)
15)
2"W
2"V
4"W
2"V
WC
14)
4"V
SINK
2"V
2"V
4"V
CO
13)
2"V
2"V
GREY
BOX
2"V
4"V
12)
2"W
2"W
LAUNDRY
4"V
4"W
TUB/SH
ALL BELOW GROUND WATER PIPING SHALL BE TYPE "K" COPPER PIPE. 3" WATER
LINES
AND LARGER SHALL BE DUCTILE IRON PIPE.
2"W
2"V
2"V
2"V
LAV
4"V
2"V
MSTR BATH
LAV
2"V
FD
TUB/SH
2" W
2"V
LAV
11)
2"W
SINK
1 1/2"V
2"V
LAV
WC
3RD FLOOR
WC
4"V
2"V
4"W
4"V
CLEAN, TEST AND BALANCE ALL SYSTEMS TO CONFORM WITH THE CITY OF PARK
RIDGE CODES. MAKE ALL REQUIRED ADJUSTMENTS.
10)
2"V
2"V
4"V
ALL DRAINAGE PIPING BELOW GRADE INCLUDING WASTE, VENT AND STORM, SHALL
BE CAST IRON, WITH PROPER CONNECTORS.
GREY
BOX
2"W
4"V
4"W
9)
4"V
2"W
4"V
8)
2"V
SINK
LAV
LAV
WC
MECH
4"V
SINK
7)
4x5 UP
THRU
ROOF
2"V
2"V
4"V
2"V
6)
4"V
FD
2" W
2"V
4"V
2"V
SH
4TH FLOOR
2"V
SH
5)
4"V
TUB/SH
PLUMBING CONTRACTOR SHALL OBTAIN AND PAY ALL FEES AND TAXES FOR
NECESSARY PLUMBING PERMITS. ALL FEES AND TAXES SHALL BE INCLUDED IN THE BID
PROPOSAL.
1 1/2"V
2"V
LAV
4)
4x5 UP
THRU
ROOF
4"V
WC
P4
4"W
2"V
3)
P3
4x5 UP
THRU
ROOF
TUB
2)
P2
TUB
1)
3/4"
3/4"
3/4"
WC
WH-1
50 GAL
SH
LAV
1/2"
LAV
WC
3/4"
1/2"
1/2"
SH
LAV
1/2"
3/4"
TUB
3/4"
K SINK
1/2"
GREY
BOX
DW
1/2"
1/2"
1/2"
1ST FLOOR
BATH 2
CW
HW
2
P1-1.2
MSTR BATH
KITCHEN
LAUNDRY
10.26.16
DRAWN BY:
AS NOTED
DESCRIPTION:
PLUMBING
DIAGRAMS AND
NOTES
P1-1.2
1 8 F T G R A V E L A L L E Y
Planting Schedule
LEGEND QUANT. BOTANICAL NAME
DECIDUOUS & ORNAMENTAL TREES
COMMON NAME
SIZE
NOTES/SPECIAL CONDITIONS
AL
Amelanchier Laevis
Serviceberry
8'ht
B&B, Clump
CC
Cercs Canadensis
Eastern Redbud
8'ht
B&B, Clump
SHRUBS
TM
18
Dark Yew
24" spr.
24" o.c.
SB
11
Spirea Bumalda
Bumald Spirea
30" spr.
B&B
SP
11
Spirea Japonica
30" spr.
B&B
SG
Switch Grass
36" spr.
B&B
Salvia (Blue)
2" pot
CG
Periwinkle
2" pot
CG
18
Vinca minor
4 CAR
DETACHED
GARAGE
GENERAL NOTES:
TREE WRAP (FOR FALL PLANTING ONLY)
PROJECT #
1634
DATE:
09.29.16
WITHIN SAUCER
2'
min.
LANDSCAPE
AREA
PLANTING MIXTURE
(SEE GENERAL NOTES)
UP
EXISTING SUBGRADE
12" MIN.
UP
FINISHED GRADE
VARIES
FINISHED GRADE
TYPICAL
TRIANGULATED SPACING
PRUNE AT THE
DIRECTION OF THE
LANDSCAPE ARCHITECT
6" MIN.
PLAN
EQUAL
EQUAL
FINISHED GRADE
PLANTING MIXTURE
(SEE GENERAL NOTES)
12" MIN
3 AL
8 VN
EXISTING SUBGRADE
EXISTING SUBGRADE
EXISTING SOIL
LEVELING COURSE
18 TM
2 SG
6"
6"
18" MIN.
EQ
UA
L
2 SG
1 CC
11 SB
11 SP
18 VM
SECTION
2 SG
4 STORY BRICK
AND BLOCK AND
FRAME
RESIDENTIAL
BUILDING
1 AL
1 CC
SODDED AREA
S U M M I T A V E .
1
L-1
10.26.16
DRAWN BY:
LANDSCAPE PLAN
SCALE:
AS NOTED
DESCRIPTION:
LANSCAPE PLAN
NOTES & DETAILS
SHEET NO.
L-1