DIRECTORY

ARCHITECT
24' - 0"

TRASH BINS

NERI ARCHITECTS

444 N. NORTHWEST HWY. SUITE 355


PARK RIDGE, IL 60068
P. 847.825.9400 F. 847.825.9451

2' - 0"

50.00'

2' - 0"

OWNER INFO
1

8' - 6"

17' - 0"

18' - 6" TYP.

2
19' - 0"

36' - 0"

1,800.0
4.0

S.F.
D.U.

ACTUAL
NUMBER OF UNITS
LOT AREA / UNIT

4
2,152.2

D.U.
S.F./D.U.

SCOPE OF WORK:

MULTI FAMILY BUILDING

APPLICABLE CODES:

INTERNATIONAL BUILDING CODE, 2015


W/ LOCAL AMMENDMENTS
ILLINOIS STATE PLUMBING CODE, CURRENT
W/ LOCAL AMMENDMENTS
NATIONAL ELECTRICAL CODE, 2014
W/ LOCAL AMMENDMENTS
INTERNATIONAL ENERGY CONSERVATION CODE, 2015
W/ LOCAL AMMENDMENTS
INTERNATIONAL MECHANICAL CODE, 2015
W/ LOCAL AMMENDMENTS
INTERNATIONAL FIRE CODE, 2015
2015 NFPA 101
W/ LOCAL AMMENDMENTS

8' - 6"
16' - 0"

24' - 7 3/4"

2,509.85
683.88

S.F.
S.F.

- SECOND FLOOR TOTAL AREA


- THIRD FLOOR TOTAL AREA
- FOURTH FLOOR TOTAL AREA

2,509.85
2,509.85
2,509.85

S.F.
S.F.
S.F.

TOTAL PROPOSED FLOOR AREA

10,723.28

S.F.

FLOOR AREA RATIO

1.2

BUILDING DESCRIPTION

ALLOWABLE FLOOR AREA (na)

0.0

S.F.

USE GROUP:

LOT COVERAGE CALCULATIONS


- FOOTPRINT OF STRUCTURE
- GARAGE

2,509.85
683.88

S.F.
S.F.

TOTAL LOT COVERAGE

3,193.73

S.F.

LOT COVERAGE

.37

ALLOWABLE LOT COVERAGE (50%)

4,304.5

S.F.

- AREA OF LOT COVERAGE


- AREA OF IMPERVIOUS SURFACE

3,193.73
2,830.66

S.F.
S.F.

-TOTAL IMPERVIOUS SURFACE

6,024.39

S.F.

TOTAL OPEN SPACE

2,584.61

S.F.

2,582.7

S.F.

REQUIRED # OF PARKING:
RES: 2 SP/D.U.

SP

PROPOSED SPACES
GARAGE
SURFACE

4
4

SP
SP

TOTAL PROPOSED SPACES

SP

R-2

CONSTRUCTION TYPE:

III-B

BULDING AREA:

10,723.28 S.F.

ZONING DATA
ZONING DISTRICT:

R-4

9' - 4"

SHEET INDEX

A6-1.1
A6-1.2
A6-1.3
A6-1.4
A8-1.1

50' - 8"

67' - 0"

4 STORY BRICK
AND BLOCK AND
FRAME
RESIDENTIAL
BUILDING

A0
G-2.1
A2-1.1
A2-1.2
A5-1.1
A5-1.2
A5-1.3

171.51'

172.93'

CONC. WALK

UP

UP

S-1
S-2

CONC. WALK

M1-1.1
M1-1.2
E1-1.1
E1-1.2
P1-1.1
P1-1.2
L-1

39' - 4"

PROJECT #

1634

DATE:

09.29.16

OPEN SPACE CALCULATIONS

SITE PLAN
GENERAL NOTES
FIRST FLOOR PLAN
TYPICAL FLOOR AND ROOF PLANS
SOUTH & EAST ELEVATIONS
NORTH AND WEST ELEVATIONS
GARAGE FLOOR PLANS AND
ELEVS
WALL SECTIONS
BUILDING SECTIONS
STAIR SECTIONS
PARTIAL STAIR PLANS
PARTITION DTLS & NOTES/ DOOR
SCHEDULE
FOUNDATION PLAN FIRST FLOOR
FRAMING
2nd FLOOR & ROOF FRAMING
PLANS
1st & TYP FLR MECH PLANS
ROOF MECH. PLAN SCHEDULES,
NOTES & DTLS
FIRST FLOOR ELEC PLAN
TYPICAL FLOOR ELECTRICAL PLAN
FIRST AND TYP FLR PLUMBING
PLNS
PLUMBING DIAGRAMS AND NOTES
LANSCAPE PLAN NOTES & DETAILS

REQUIRED OPEN SPACE (30%)


OFF STREET PARKING CALCULATIONS

5' - 8"
25' - 0"

5' - 0"

5'-0" SIDE SET BACK

25'-0" FRONT SETBACK

FLOOR AREA CALCULATIONS


- FIRST FLOOR TOTAL AREA
garage

R-4

CODE SUMMARY

PAVEMENT

18' - 6" TYP.

8,609.0

ALLOWED
MIN LOT AREA/D.U.
NUMBER OF UNITS

79' - 7 3/4"

5'-0" SIDE SET BACK

LOT AREA:
S.F.
ZONING DISTRICT:
MIN LOT AREA CALCULATIONS

4 CAR
DETACHED
GARAGE

515 SUMMIT

RENE LAMAGNA
132 CALAIS ST
LAGUNA NIGUEL, CA 92677

PROJECT DATA

20'-0" REAR SET BACK

ADDRESS:

FOR BIDDING ONLY, NOT FOR CONSTRUCTION

18' - 6"

515 SUMMIT AVE.


PARK RIDGE, IL 60068

5' - 6"

PROJECT DATA

MULTY FAMILY BUILDING

1 8 F T G R A V E L A L L E Y

LOCATION MAP

50.00'

SITE LOCATION

CONC.
DRIVE

EXISTING CONCRETE DRIVE


AND APRON TO BE
REMOVED

10.26.16

S U M M I T A V E .
1
A0

SITE PLAN

DRAWN BY:

ISSUED FOR PERMIT


FZM

APPROVED BY: G.C.N.


SCALE:

AS NOTED

DESCRIPTION:

SITE PLAN

SCALE: 3/32" = 1'-0"


SHEET NO.

A0

GENERAL NOTES

1.

STONE AND BRICK SHALL BE AS APPROVED BY THE OWNER.


ALLOW $380/M FOR BRICK ONLY.

1.

WHERE AND WHEN CALLED FOR ALL CLEAN GRANULAR FILL


MATERIAL SHALL BE COMPACTED TO A MINIMUM OF 95% OF "ASTM"
D-1557-70 (MINIMUM PROCTOR DENSITY).

1.

ALL BEAMS, LINTELS OR STRUCTURAL MEMBERS TO BE NO. 2 SOUTHERN


PINE (KILN DRIED) W/ "E" = 1,600,000 AND Fb = 1,300 (OR EQUAL).

1.

INCLUDED AS PART OF THESE DOCUMENTS IS THE "GENERAL CONDITIONS FOR


CONSTRUCTION", AIA DOCUMENT A-201, ARTICLE 1 THROUGH 14 INCLUSIVE.

2.

CONCRETE MASONRY UNITS (CMU) SHALL BE AS INDICATED


ON THE PROJECT DRAWINGS.

2.

2.

ANCHORS AND TIES SHALL BE ZINC-COATED STEEL AND


SHALL MEET "ASTM" A-525, CLASS G-60.

THESE DRAWINGS INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF THE
ARCHITECTURAL DESIGN CONCEPT, DIMENSIONS, MAJOR ELEMENTS AND MATERIALS. THESE
DRAWINGS DO NOT NECESSARILY INDICATE OR DESCRIBE ALL WORK REQUIRED FOR THE
FULL COMPLETION OF THE PROJECT

3.

WHERE AND WHEN CALLED FOR ALL CLEAN GRANULAR FILL


MATERIAL SHALL BE COMPACTED TO A MINIMUM OF 95% OF "ASTM"
D-1557-70 (MINIMUM PROCTOR DENSITY).

ALL FLOOR JOISTS SHALL BE 14" DEEP OPEN WEB BY "TRUS-JOIST" CORP. @
16" O.C. (UNLESS NOTED OTHERWISE). STAIR HEADERS TO BE 11-7/8" DEEP
TJI (GIRDER TRUSS) AND TRIMMERS TO BE 2 - 1 3/4" x 14" "MICRO-LAM"
(UNLESS NOTED OTHERWISE). FURNISH ONE (1) SET OF SEPIA SHOP
DRAWINGS TO THE GENERAL CONTRACTOR TWO (2) WEEKS PRIOR TO
FABRICATION FOR REVIEW AND COMMENT, AND SHALL BE SIGNED AND
SEALED BY A REGISTERED STRUCTURAL ENGINEER LICENSED IN THE STATE
OF ILLINOIS. ANY MATERIALS DELIVERED TO THE JOB SITE WITHOUT
APPROVED SHOP DRAWINGS WILL BE REJECTED. ALSO THE TRUSS
MANUFACTURER SHALL SUPPLY THE GENERAL CONTRACTOR WITH A COPY
OF HIS CERTIFICATE OF INSURANCE. SEE 06190 AND 06195 FOR PRODUCT
SPECIFICATIONS AND INFORMATION.

2.

3.

EXCAVATIONS DEEPER THAN THE ELEVATION OF FOOTING MUST BE


CLEARED THROUGH THE ENGINEERING OFFICE.

3.

THE GENERAL CONTRACTOR AND HIS SUBCONTRACTORS SHALL FURNISH ALL OF THOSE
ITEMS AND LABOR REQUIRED FOR THE FULL COMPLETION OF THIS PROJECT IN A FIRST CLASS
WORKMANSHIP LIKE MANNER.

4.

ALL INTERIOR BEARING WALLS AND SHAFTS SHALL BE (1) ONE HOUR RATED CONSTRUCTION
USING 5/8" TYPE-X U.L. RATED DRY WALL (BOTH SIDES)

5.

THIS CONTRACTOR SHALL INSTALL SMOKE DETECTORS AS REQUIRED BY THE CITY OF PARK
RIDGE CODE

6.

INTERIOR FINISHES SHALL NOT EXCEED CLASS 1, 0-25 FLAME SPREAD, 200 SMOKE.

7.

THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR FIELD VERIFICATION OF ALL


DIMENSIONS AND CONDITIONS BEFORE EXECUTION OF ANY WORK AND SHALL REPORT ANY
DISCREPANCIES TO THE ARCHITECT IN WRITING.

8.

THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THE ADHERENCE TO COMPLY WITH ALL
APPLICABLE CITY, STATE, AND NATIONAL CODES AND ORDINANCES.

9.

THE CONTRACTOR SHALL VERIFY ALL PARTITION LAYOUTS WITH THE ARCHITECT BEFORE
PROCEEDING WITH ANY FRAMING.

9.

10.

11.

FLASHING @ ALL MASONRY LINTEL OPENINGS AND WEEP


HOLES SHALL BE OF THE TYPE AS INDICATED ON THE
PROJECT DRAWINGS. WEEPS SHALL BE WICK TYPE,
INSTALLED IN EXTERIOR WALLS AT TWENTY FOUR (24) INCH
CENTERS (MAX) SPACING.
PROTECT ALL MASONRY MATERIAL AGAINST MOISTURE. DO
NOT USE REINFORCING OR TIES HAVING LOOSE RUST OR
OTHER COATING WHICH AFFECT BONDING.
LAY UP WALLS PLUMB AND TRUE WITH COURSES LEVEL,
ACCURATELY SPACED AND COORDINATED WITH OTHER
WORK. ALL BOND SHALL MATCH EXISTING UNLESS INDICATED
OTHERWISE. ALL HORIZONTAL JOINTS SHALL BE LEVEL AND
ALL VERTICAL JOINTS SHALL BE PLUMB, WITH A TOLERANCE
OF PLUS OR MINUS ONE QUARTER (1/4) INCH FOR THE HEIGHT
(TOP AND BOTTOM) OF THE WALL.
BRICK WORK SHALL BE REINFORCED WITH CORROSION
RESISTANT TIES, SPACED AT SIXTEEN (16) INCHES VERTICAL
CENTERS AND THIRTY TWO (32) INCHES HORIZONTAL
CENTERS.

12.

EXPOSED JOINTS SHALL BE TOOLED AND BRUSHED.

13.

CLEAN ALL MASONRY WORK INCLUDED IN THIS SECTION.


PROTECT ADJOINING WORK FROM DAMAGE FROM ALL
CLEANING OPERATIONS.

14.

CONTRACTOR SHALL PROTECT FOUNDATION AGAINST LATERAL


DISPLACEMENT, HEAT OR FREEZING CONDITIONS.

6.

7.

8.

PROVIDE 2-#5 BARS (TOP AND BOTTOM) CONTINUOUS IN CONCRETE


WALL UNLESS NOTED OTHERWISE. LAP AND TIE BARS 3'-0" AT
SPLICES AND PROVIDE 4'-0" LONG CORNER BARS (UNLESS NOTED
OTHERWISE).
ALL REINFORCED CONCRETE WORK SHALL BE IN ACCORDANCE WITH
THE LATEST EDITION OF "BUILDING CODE REQUIREMENTS FOR
REINFORCED CONCRETE" AS PUBLISHED BY "THE AMERICAN
CONCRETE INSTITUTE" (A.C.I. STANDARD 318-83).

ALL REINFORCING STEEL SHALL CONFORM TO "ASTM" A-615, GRADE


60 SPEC. FOR NEW BILLET STEEL.

10.

ALL WELDED WIRE MESH SHALL BE LAPPED (2) TWO FULL MESH
PANELS AND TIED SECURELY. WELDED WIRE MESH SHALL
CONFORM TO "ASTM" A-185 SPEC.

10.

THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF ALL INCOMING


UTILITIES.

11.

WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE


DRAWINGS.

12.

THE GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL:


A
COMPLY WITH ALL LOCAL, STATE AND NATIONAL CODES AND ORDINANCES.
B
PERFORM ALL WORK IN A FIRST CLASS WORKMANSHIP LIKE MANNER AND IN NO WAY
DAMAGE OR WEAKEN THE STRUCTURAL STRENGTH OF THE BUILDING.
C
REMAIN RESPONSIBLE FOR COMPLIANCE WITH THE PROVISIONS OF THE
OCCUPATIONAL SAFETY AND HEALTH ACT, (OSHA) LATEST ADDITION.
D
ALL WORK SHALL BE GUARANTEED FOR ONE YEAR AFTER SUBMITTAL OF
COMPLETION OF WORK.
E
MAINTAIN THROUGHOUT THE CONSTRUCTION PERIOD, A CERTIFICATE OF
INSURANCE FOR ALL LIABILITIES, WITH A HOLD HARMLESS CLAUSE, PROTECTING THE
OWNER AND ARCHITECT.

13.

THE GENERAL CONTRACTOR'S SUBCONTRACTORS SHALL COMPLETELY HOOKUP AND


CONNECT ALL EQUIPMENT AND FURNISH ALL NECESSARY APPENDAGES.

14.

ALL WINDOW GLASS, MIRRORS, FLOORS AND WALL TILE SHALL BE CLEANED AND WASHED
UPON COMPLETION OF THE PROJECT BY THE GENERAL CONTRACTOR.

15.

THE PREMISES SHALL BE KEPT IN A BROOM SWEPT FINISH CONDITION DURING ALL PHASES OF
THE CONSTRUCTION. (ALL CONTRACTORS AND SUBCONTRACTORS SHALL BE RESPONSIBLE
FOR CLEANING UP AND DISPOSING OF THEIR LITTER AND LEFT OVER MATERIALS ON A
REGULAR BASIS AND LEAVE THE PROJECT IN A BROOM SWEPT FINISH CONDITION UPON
COMPLETION OF THEIR PORTION OF THIS PROJECT).

16.

THE ENTIRE INSTALLATION SHALL BE PERFORMED IN FIRST CLASS WORKMANSHIP LIKE


MANNER. THE COMPLETED SYSTEMS SHALL BE FULLY OPERATIONAL. ACCEPTANCE BY THE
OWNER SHALL BE A CONDITION OF THE CONTRACT.

17.

ALL WORK SHALL BE COORDINATED WITH ALL OTHER TRADES IN ORDER TO AVOID
INTERFERENCE, PRESERVE MAXIMUM HEAD ROOM AND AVOID OMISSIONS.

18.

RECESSED FIXTURES IN INSULATED CEILINGS MUST BE APPROVED BY THE CITY OF PARK


RIDGE.

19.

ALL WORK PERFORMED MUST COMPLY WITH THE CITY OF PARK RIDGE CODE.

20.

THE EXCAVATOR SHALL REMOVE ALL EXCESS MATERIAL DOWN TO 6" (SIX INCHES) BELOW
FINISH GRADE, INCLUDING PARKWAYS.

2" x 4" KEY


IF REQ'D

21.

THE ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL ONE (1) 4 x 4 WOOD POST WITH A
TEMPORARY METER HEAD AND TWO (2) 110 V. AND ONE (1) 220 V.OUTLET TO BE USED BY ALL
OTHER TRADES DURING THE COURSE OF CONSTRUCTION OR UNTIL EACH UNIT IS ELECTRIFIED
AND SHALL BE BILLED TO THE GENERAL CONTRACTOR.

STD. 90
HOOK

22.

THE GENERAL CONTRACTOR TO PROVIDE TEMPORARY FENCING AND BARRICADES AROUND


THE ENTIRE SITE TO BE PROTECTED AND AT ANY INTERIOR FLOOR OPENINGS THAT MIGHT
CAUSE A HAZARD TO ALL.

23.

APPROVED PLANS SHALL BE ON SITE FOR ALL INSPECTIONS

24.

ALL CONTRACTORS AND THEIR REPRESENTATIVES WORKING ON THIS PROJECT SHALL AT ALL
TIMES PRIOR AND DURING THE COURSE OF THEIR ACTIVITY BE RESPONSIBLE FOR THE SAFETY
OF THEIR EMPLOYEES, AS WELL AS OTHERS AND IN THE CARE OF THE PROPERTY. EACH AS
REPRESENTATIVES OF THEIR EMPLOYEES SHALL ASCERTAIN THAT THE CONDITIONS UNDER
WHICH THEY WILL BE REQUIRED TO ACCOMPLISH THEIR WORK ARE SAFE WITHIN GOOD
SAFETY PRACTICES AND MEET ALL CONCERNED REGULATIONS OF THE OCCUPATIONAL SAFETY
AND HAZARD ACT OR OTHER GOVERNING REGULATIONS. THE BEGINNING OF WORK BY A
CONTRACTOR SHALL INDICATE SATISFACTION CONCERNING SAFETY AND FULL RESPONSIBILITY
FOR ACCIDENTS OR DAMAGE. IF UNSATISFIED, THE CONTRACTOR SHALL INDICATE WHAT SO
EVER ACTION OR DEVICES NECESSARY TO RENDER SAFETY CONDITIONS FOR LIFE AND
PROPERTY AS ARE RELATED TO HIS ACTIVITY. IF THE WORK OF OTHER PARTIES OUTSIDE OF
THEIR ORGANIZATION IS UPON INSPECTION FOUND AT ANY TIME TO BE UNSAFE, HE SHALL
STOP WORK IMMEDIATELY AND NOTIFY THE GENERAL CONTRACTOR, ARCHITECT AND OWNER.
THE BEGINNING OF WORK SHALL INDICATE SATISFACTION. ACCEPTANCE OF A CONTRACT
SHALL INDICATE ACCEPTANCE OF THESE REQUIREMENTS.

11.

2 x 4 TOP PLATES TO BE DOUBLED BELOW FLOOR TRUSS BEARING.

REFLECTED FRAMING SHOWN ON PLAN.

14.

EXTERIOR OR LOAD BEARING WALLS WITH PLATES CUT, DRILLED OR


NOTCHED MORE THAN 50% OF THE WIDTH OF THE STUD SHALL HAVE A
GALVANIZED METAL TIE 16 GAGE AND 11/2 INCHES (11/2") WIDE FASTENED TO
EACH PLATE.

15.

EXTERIOR OR LOAD BEARING WALLS WITH STUDS DRILLED WITHIN 5/8" OF


THE FACE OF THE STUD SHALL BE REINFORCED WITH A STRUCTURAL STUD
SHOE.

16.

TYPE 1A-FIRECODE INTUMESCENT ACRYLIC FIRESTOP SEALANT- TO BE


USED AS FIRESTOP AND DRAFTSTOP AT ALL REQUIRED LOCATIONS AS
DESCRIBED IN IRC R602.8

13.

POUR ALL SLABS-ON-GRADE IN CHECKERBOARD FASHION


BETWEEN.CONSTRUCTION JOINTS IN AREAS NOT TO EXCEED 600 SQ.
FT. WITH A MINIMUM OF 24 HOURS BETWEEN ADJACENT POURS.

14.

NO CALCIUM CHLORIDE SHALL BE USED IN ANY CONCRETE OR


MORTAR.

15.

ALL STRUCTURAL STEEL SHALL CONFORM TO "ASTM" A-36 SPEC.


(UNLESS NOTED OTHERWISE).

16.

SET STEEL LINTELS AND MISC. STEEL IN MASONRY AS


INDICATED ON PLANS. PROVIDE 4" MIN. BEARING @ EACH
END OF BEARING.

18.

CONCRETE CONTRACTOR TO SUBMIT ALTERNATIVE PRICE FOR


REPLACING DAMAGED SECTIONS OF PUBLIC SIDEWALK

19.

KEYNOTE SHOWN BY:


19.1. 4" CONCRETE SLAB ON GRADE WITH ONE LAYER WWF 66-1010
AT 1-12" CLEAR @ TOP.

17.

CUTS, NOTCHES AND HOLES BORED IN TRUSSES, LAMINATED VENEER


LUMBER, GLUE-LAMINATED MEMBERS OR I-JOISTS ARE NOT PERMITTED
UNLESS THE EFFECTS OF SUCH ARE SPECIFICALLY ADDRESSED. (SECTION:
R502.8.2)

18.

MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR THE PREENGINEERED OPEN WEB FLOOR JOISTS SHALL BE ON THE JOBSITE AT THE
TIME OF INSPECTIONS.

36 DIA. LAP.

19.2. SEE DETAILS FOR BRICK LEDGE REINFORCEMENT.

1
A-1

1
A-1

19.3. DEPRESS TOP OF WALL 8" AT ENTRY (UNLESS NOTED


OTHERWISE)- SEE ARCHITECTURAL FOR LOCATION.
19.4. 5" CONCRETE SLAB ON GRADE WITH ONE LAYER WWF 66-1010
AT 1-1/2" CLEAR @ TOP.(GARAGE)

1
A-1

DETAIL AREA SYMBOL

1
A-1

EXTERIOR BUILDING ELEVATION

1D
1C

1A
1B
SECOND FLOOR

ELEVATION REFERENCE VERTICAL

ELEV: + 11'-8"

19.6. PRIVATE SIDEWALKS ARE TO BE 4" THICK WITH A MINIMUM OF


4" GRADE CA-6 STONE BASE. PUBLIC SIDEWALKS ARE TO BE 5"
THICK WITH A MINIMUM OF 4" GRADE CA-6 STONE BASE.
19.7. BRICK PAVER PATIO TO BE CONSTRUCTED OF A MINIMUM 4"
COMPACTED GRADE C.A. 6 STONE BASE AND 1-1" SAND. A
CONCRETE BASE IN LIEU OF THE MINIMUM OF CA-6 STONE IS
ACCEPTABLE.
NOTE
CONCRETE CONTRACTOR SHALL COORDINATE ALL CHASES AND SLEEVES
IN FOUNDATION WALLS WITH PLUMBING AND HEATING CONTRACTORS.

+8'-8"

A 01
01

WALL
CONST. JOINT

19.5. ALL SECTIONS OF DRIVEWAY INCLUDING THE APRON SECTIONS


OF THE DRIVE (FROM THE SIDEWALK TO THE HOUSE) TO BE
CONSTRUCTED OF:
19.5.1.
A MINIMUM 4" COMPACTED GRADE C.A. 6 STONE BASE,
WITH 6" CONCRETE;
OR
19.5.2.
A 8" COMPACTED GRADE C.A. 6 STONE BASE, WITH 2"
CLASS I BITUMINOUS SURFACE. NO WIRE MESH ALLOWED UNDER
PUBLIC WALK & PARKWAY. MESH REQUIRED ON PRIVATE SECTIONS
OR ENTIRE POUR TO BE FIBER MESH. NO PEA GRAVEL ALLOWED

1
A-1

WINDOW TAG

ROOF SHEATHING SHALL BE 5/8" DOUGLAS FIR CDX PLYWOOD W/


IDENTIFICATION INDEX NO. 32/16. ALL TYPICAL FLOORS AND WALK ON DECKS
SHALL BE 3/4" CDX PLYWOOD INDEX NO. 24/48. ALL TO BE GLUED AND
NAILED.

13.

INSTALL ALL THRU-WALL SLEEVES OR CHASES AS REQUIRED BY THE


ELEC./PLUMBING/ OR HVAC CONTRACTOR, LOCATE AS DIRECTED.

PARTITION TAG

10.

ALL CONSTRUCTION JOINTS SHALL BE THOROUGHLY CLEANED OF


LAITANCE WITH A WIRE BRUSH AND WATER IMMEDIATELY PRIOR TO
POURING OF SUBSEQUENT OR NEW CONCRETE.

17.

DOOR TAG

ROOF: (LIVE LOAD = 20 P.S.F., DEAD LOAD = 10 P.S.F.)


FLOOR: (LIVE LOAD = 40 P.S.F., DEAD LOAD = 15 P.S.F.)
PARTITIONS: ASSUMED WALL LOAD = 20 lb/LF.
SNOW LOAD: 25 lb P.S.F.

12.

PROTECT ALL WORK FROM FREEZING.

ELEVATION REFERNCE SPOT

6.
7.
8.
9.

ALL DOUBLE TRUSSES OR "MICRO-LAM" BEAMS BEARING ON FRAME WALLS


TO BE CARRIED DOWN TO FOUNDATION ON TRIPLE STUDS GLUED AND
SPIKED AS INDICATED.

15.

INTERIOR ELEVATION

ALL EXTERIOR CORNERS SHALL BE LET-IN METAL DIAGONAL WIND BRACING


BY "SIMPSON" #CWB-126, OR 5/8" CDX PLYWOOD.

12.

SPADE OR VIBRATE CONCRETE FOUNDATIONS AS NECESSARY TO


AVOID HONEYCOMBING.

PARTIAL BUILDING SECTION

ALL WOOD PLATES AND SILLS BEARING DIRECTLY ON CONCRETE SHALL BE


PRESSURE TREATED FOR ROT AND TERMITES.

CONCRETE COVER SHALL BE 1" TOP AND BOTTOM FOR SLABS; 1-1/2"
FOR BEAMS ,COLUMNS AND WALLS; 3" FOR FOOTINGS, MATS AND
GRADE BEAMS.

16.

FULL BUILDING SECTION

4.

11.

GROUT ALL VOIDS AT JAMBS, HEADERS, FOUNDATIONS AND


SILLS. POINT JOINTS AS NECESSARY INCLUDING POCKETS
AND VOIDS.

SYMBOLS LIST

ALL WOOD LINTELS OVER DOORS AND WINDOWS SHALL BE 2 - 2 x 12's


(UNLESS NOTED OTHERWISE).

5.

ALL CONCRETE TO HAVE A MINIMUM ULTIMATE STRENGTH OF 3000


P.S.I. AT THE END OF 28 DAYS UNLESS NOTED OTHERWISE).

9.

3.

PLUMBING CONTRACTOR TO VERIFY SIZE AND LOCATION OF ALL SLEEVES


AND CHASES NECESSARY TO INSTALL A COMPLETE SYSTEM AS REQUIRED
PER THE PROJECT DRAWINGS. THE PLUMBING CONTRACTOR SHALL
COORDINATE ANY CHANGES OR ADDITIONAL INFORMATION WITH THE
CONCRETE AND GENERAL CONTRACTORS PRIOR TO ANY POURING OF
FOOTINGS AND FOUNDATIONS. THE PLUMBING CONTRACTOR SHALL BE
RESPONSIBLE FOR SEALING OFF AND MAKING WATERTIGHT ALL
PENETRATIONS MADE BELOW GRADE.

6"

36 DIA.

MIN. 2'-0" MIN.

PROVIDE CORNER
BARS SAME SIZE
AND SPACING
AS HORIZONTAL
BARS

WALL
CORNER

2'-0" MIN.

8.

EXPANSION AND CONTROL JOINT FILLERS SHALL BE PREFORMED RUBBER. THE EXTENT AND LOCATION SHALL BE AS
INDICATED ON THE PLANS.

5.

36 DIA.

7.

LIMESTONE SILLS AND CAPS WHERE REQUIRED SHALL BE


"INDIANA" LIMESTONE, BUFF COLOR, VARIEGATED STONE
SHALL NOT BE PERMITTED.

WALL FOOTINGS TO HAVE 6" PROTECTIONS FROM EACH FACE OF


WALL AND BE 1'-0" DEEP (UNLESS NOTED OTHERWISE).

2'-0" MIN. MIN.

6.

MORTAR SHALL CONSIST OF PORTLAND CEMENT, HYDRATED


LIME AND SAND IN A PROPORTION OF 1:1:6 IN ACCORDANCE
WITH "ASTM" C-270 FOR TYPE "N" MORTAR.

4.

6"

5.

JOINT REINFORCING SHALL BE PREFABRICATED TRUSS-TYPE,


SIMILAR TO "DUR-O-WALL" AND SHALL MEET "ASTM" A-153,
CLASS B-2.

36 DIA.

4.

PROVIDE DOWELS
SAME SIZE AND
SPACING AS
HORIZONTAL BARS

WALL
INTERSECTION

TYPICAL FOUNDATION WALL DETAILS


VERTICAL REINFORCING NOT SHOWN

25.
26.

NORTH ARROW

27.

PROJECT #

1634

DATE:

09.29.16

10.26.16

FOR BIDDING ONLY, NOT FOR CONSTRUCTION

FRAMING NOTES

515 SUMMIT AVE.


PARK RIDGE, IL 60068

GENERAL CONCRETE NOTES

MULTY FAMILY BUILDING

MASONRY NOTES

ISSUED FOR PERMIT

THE ARCHITECT ASSUMES NO RESPONSIBILITY FOR CONSTRUCTION OTHER THAN SHOWN ON


THESE DRAWINGS.

DRAWN BY:

THIS SET OF PLANS IS PROTECTED UNDER UNITED STATES GOVERNMENT COPYRIGHT LAWS
AND MAY NOT BE REPRODUCED, REPRINTED OR COPIED IN ANY MANNER, EXCEPT BY
APPROVAL OF ARCHITECT IN WRITING. ANY PERSON OR FIRM KNOWINGLY REPRODUCING,
REPRINTING, OR PHOTOCOYPING ANY OF THIS WORK WILL BE SUBJECT TO LAWSUITS AND
SUCH PENALTIES AS THE LAW ALLOWS.

SCALE:

AS NOTED

DESCRIPTION:

GENERAL NOTES

THESE DRAWINGS WERE PREPARED UNDER MY DIRECTION AND ARE CORRECT TO THE BEST
OF MY KNOWLEDGE IN ACCORDANCE WITH THE BUILDING LAWS OF CITY OF PARK RIDGE.

FZM

APPROVED BY: G.C.N.

SHEET NO.

G-2.1

A5-1.2

4' - 8"

39' - 4"

1
A6-1.2

16' - 9"

17' - 11"

16' - 1"

18' - 7"

14' - 3"

3' - 6 1/4"

1' - 10"

5' - 9"

5' - 9"

3' - 6 1/2"

2
A6-1.1

1' - 0"

5B

A.1

4' - 8"

HANDRAIL
3' - 7 1/4"

9' - 7"
2
8' - 4"

A6-1.3

1B

3 1/2"

4 3/4"
1' - 2 1/2"

FD

1A

6' - 6"

17R @ 6.70"
16T @ 11"

8' - 9 3/4"

1A

STORAGE

113

LIGHT SWITCH
EXIT SIGN TO BE
MOUNTED ON STRIKER
SIDE OF DOOR

5B
BEDROOM 2

104

4"

1' - 10 1/2"

24' - 4 1/2"

EQ

5B

5B

A6-1.1

2'-10"

2' - 0" 6"


1

8' - 0 1/4"

3' - 2 1/4"

3' - 1 1/2"

3' - 7 1/4"
11' - 4 1/2"

5' - 10 1/2"

TO THE BOTTOM
INTERIOR OF THE
CABINET

9' - 2"

1' - 6"

5' - 3"

17' - 5"

8' - 0 1/2"

8' - 0"
16' - 0 1/2"

39' - 4"
1

8"

1'-3"

EXIT

N 08
03

1' - 6"

CL
ELECTRICAL / PHONE / DATA
OUTLETS

10' - 0"

1' - 2 1/2"

6'-0" - 7'-0"

PULL

CL

3'-8"

4'-0"

CL

3'-8"

CL
6'-8"

6'-6" MIN

ELECTRICAL / PHONE / DATA


OUTLETS @ COUNTERS,

112

8' - 11 3/4"

6"

TERRACE

2' - 11 1/2"

4' - 4 1/2"

2' - 3"

TEN-POUND ABC TYPE FIRE


EXTINGUISHERS TO BE
INSTALLED. TRAVEL
DISTANCE TO AN
EXTINGUISHER NOT TO
EXCEED SEVENTY-FIVE FEET
(75').

4"

5' - 1 1/2"

PULL STATION

7' - 0"

THERMOSTAT

1
5' - 1"

CL

3' - 10"

6' - 11 1/2"

4"

N 06
05

S&R

1' - 6"

STROBE / LIFE SAFETY


SPEAKER

N 07
05
EQ

5B

C
6' - 7"

"TENT" STYLE SIGNAGE


AT EACH
EXTINGUISHER
LOCATION

6' - 6 3/4"

EQ

4 3/4"

EQ

2' - 4"

2' - 3 1/4"

S&R

1B

5"

EXIT SIGN (PROVIDE BOTH HIGH & LOW


EXIST SIGN @ EACH INDICATED
LOCATION ON SHT E1-1.1

EXIT

67' - 0"
5' - 9"

4"

FOR BIDDING ONLY, NOT FOR CONSTRUCTION

9' - 0 1/2"
5' - 0"
1' - 4 1/2"

5B

515 SUMMIT AVE.


PARK RIDGE, IL 60068

HANDRAIL

1A

3' - 5 1/2"

114

A5-1.1

MULTY FAMILY BUILDING

B 10
06

5B

1' - 2 1/2"

111

3
A6-1.3

2' - 11 1/2"

STAIRS #1

8 3/4"

6 3/4"
8"

5' - 4"

LOBBY

6"

106

4 MAILBOXES

6 3/4"

3' - 5 1/2"

17' - 1 1/4"

09.29.16

2"
BATH 2

14' - 11 1/2"

UP

21' - 5"

3' - 5 1/2"

2' - 4"

6' - 10 3/4"

1B

2' - 0"

18" FLUSH TILE


HEARTH
36" GAS BURNING
FIREPLACE

5' - 0"

6' - 7 1/2"

N 09
03

17' - 5 1/2"

2' - 3 1/4"

101

4' - 9 1/4"

SEAT

3' - 8"

N 07
05

B 02
02

LIVING/ DINING

DATE:

EQ
6' - 9"

1B

1634

36' - 10 1/2"

5' - 0"
6 3/4"
5' - 4 1/2"

EQ
EQ

S&R
EQ

4"

7' - 10"

6' - 9 1/2"
5

WH

A6-1.3
3' - 2 1/2"

105

110

9' - 7"

13' - 6 1/2"
MASTER
BATHROOM

5' - 0"

2B

5B

7' - 9 1/2"

4"

4' - 6 3/4"

N 03
03

MECH CLOSET
FD

PROJECT #

4"

3"

5' - 0"

10' - 3"

1' - 0"

4' - 11 1/2"

5B

2B

4"

ISLAND

SINK
18' - 3 1/2"

2B
1' - 0"

103

A5-1.2 2

F-1

2' - 0" 6 3/4"

KITCHEN

DW

7' - 3"

RANGE

109

N 08
04

5' - 6"

5B

HALL

SHELVES
EQ
EQ

108

S&R

2B

6' - 10 1/4"

6"

1' - 9 1/4"

N 07
05

N 03
04

WIC

3' - 8 1/4"

6 3/4"

1A

9' - 0"

N 07
05

EQ

117

1B

REF.

3' - 11 3/4"

S&R

SPRINKLER RM

N 03
03

3' - 8 1/4"

2' - 0"

4" 4"

N 04
04

S&R

L.T.

EQ

FD

107

7' - 9"

FD

11 1/2"

4"

4' - 8 1/2"

34' - 10"

A6-1.1

3' - 0 1/4"

B 10
06

600 AMP
MAIN PANEL

ELECTRICAL RM

A6-1.2

8' - 2 3/4"

B 10
06

LAUNDRY /
MUDROOM

2 STACKED
STORAGE
CAGES 1B

116

50' - 8"

3' - 7 3/4"

6' - 10 3/4"

118

100 AMP
COMMON
HOUSE PANEL

67' - 0"

7' - 6"

2 STACKED
STORAGE
CAGES

STORAGE

1' - 6" 1' - 10"

6' - 10"

8"

1B

5' - 10 1/2"

B 10
06

102

B 02
02
8"

13' - 0 1/4"

4' - 10"

8' - 1 1/4"

3' - 3 1/4"

8 1/2"

HANDRAIL

MASTER
BEDROOM

7' - 10 3/4"

115

4' - 3 1/4"

UP

3' - 8"

17R @ 6.70"
16T @ 11"

13' - 5 1/4"

1
A6-1.4

STAIRS #2

20' - 4 1/4"

12' - 7 1/4"

B 01
01

10.26.16
DRAWN BY:

ISSUED FOR PERMIT


FZM

APPROVED BY: G.C.N.


SCALE:

AS NOTED

DESCRIPTION:

FIRST FLOOR PLAN

A5-1.1

DEVICE LOCATION
1/2" = 1'-0"

1
A2-1.1

1st FLOOR
SCALE: 1/4" = 1'-0"

SHEET NO.

A2-1.1

3
A5-1.2

4' - 10 3/4"

2' - 7 1/4"

39' - 4"

15' - 10 1/4"
8"

15' - 2"

11 1/2"

9' - 7 3/4"

2' - 11 1/4"

2' - 7"

18' - 7"

A6-1.2

16' - 8 1/4"

11 1/2"

5' - 9"

5' - 8 1/2"

5' - 6"

2' - 7 3/4"
42" HT ALUMINUM
RAILING WITH
TEMPERED
GLASS PANELS

5' - 6"

7' - 7"

A6-1.1

4
BALCONY

MASTER
BEDROOM

1B

UP

202

8"

4 3/4"
9' - 0 1/2"

4A
6' - 8"

3' - 5 1/2"

9' - 7"

4
A6-1.3

214

1A
1A

STAIRS #1

4"
2' - 0"
17' - 5"
BALCONY

11' - 7 1/4"

2 1/4"

EQ
BEDROOM 2

204

4A

4A

4A

8"

1' - 6"

8' - 11 3/4"

212

2' - 11 1/2"

9' - 1"

4"

1' - 10 1/2"

5' - 1"

6' - 1 1/2"

N 06
05

N 05
03

S&R

4"

6"

EQ.

8' - 0 1/4"

3' - 5 1/2"

3' - 1 1/2"
2' - 10 3/4"

3A

6' - 9 1/4"

N 07
05
EQ

4' - 7 1/2"

4' - 10 3/4"

6' - 3 3/4"

11 1/2"

H.P.

6' - 0 1/4"

8"

EQ
1' - 2"

2' - 0" 6"

S&R

1B

2' - 4"

2' - 0"

2' - 6 1/2"

2' - 3 1/4"

215

66' - 9 1/4"

8"

3' - 5 1/2"
STORAGE

18" FLUSH TILE


HEARTH
36" GAS BURNING
FIREPLACE

A5-1.1

515 SUMMIT AVE.


PARK RIDGE, IL 60068

10

B 10
06

17R @ 6.70"
16T @ 11"
6"

11 1/2" 5' - 0"

3A

213

UP

FOR BIDDING ONLY, NOT FOR CONSTRUCTION

6 3/4"
8"

14' - 0 1/4"

1A

3' - 5 1/2"

09.29.16

6"

4"

207

4"
8"

DATE:

MULTY FAMILY BUILDING

17' - 9 3/4"

BATH 2

23' - 9 1/2"

A6-1.2

16' - 3 1/2"

2' - 3 1/4"

201

2' - 8"

VESTIBULE

A6-1.3
DN
1B

1634

5"
2B
6' - 10 3/4"

1A

B 02
02

17R @ 6.70"
16T @ 11"

3' - 2 1/2"

33' - 10 3/4"
SLOPE 1/4" MIN.

11 1/2"
5

SEAT

N 07
05
N 09
03

PROJECT #

EQ

1' - 2"

7' - 9 1/2"

5' - 0"
5' - 4 1/2"

EQ
EQ

2B

6' - 9"

8"

LIVING / DINING

7' - 2 1/2"

S&R

6"

7' - 10"

4 3/4" 206

5' - 0"

EQ

3A

ROOF ACCESS
HATCH

MASTER
BATHROOM

3' - 0"

4' - 6 3/4"

WH

3' - 0 1/4"

5' - 0"

10' - 3"

1' - 0"

5' - 4 1/2"

N 03
03

3' - 3 1/4"

ISLAND

S&R

FD

N 07
05
2B

F-1

3A

2B

209

6 3/4"

3' - 8 1/4"

EQ

1' - 0"

203

SINK
18' - 3 1/2"

211

N 03
04

WIC

3' - 8"

EQ

KITCHEN

DW

7' - 3"

GFI

MECH CLOSET

N 08
04

A5-1.2 2

2B

SHELVES

5' - 6"

RANGE
BATHROOM
EXHAUSTS

HALL

210

S&R

1' - 9 1/4"

GFI

S&R

3' - 8 1/4"

6 3/4"

EQ

2' - 9"

2' - 0"

EQ.

N 03
03

4" 4"

3' - 11 3/4"

N 08
04
EQ
EQ

2' - 0"

N 03
03

3' - 3"

N 04
04

6' - 10 1/4"

4' - 6 3/4"

REF.

50' - 8"

A6-1.1

2' - 0" 6 3/4"

6' - 8 3/4"

2B

AC-1

66' - 9 1/4"

S&R

L.T.

3' - 8 1/4"

11' - 10"

205

N 06
05

GFI

208

4' - 3 1/4"

FD

4 3/4" 3' - 6 3/4"

4"

7' - 9"

0"
R1
5' -

LAUNDRY /
MUDROOM

8' - 7 3/4"

BEDROOM 3

FURNACE INTAKE

AC-1

3' - 7 3/4"

4' - 9 1/4"

1B

AC-1

7' - 6"

7' - 9"

6 3/4"

3A FURROUT 12' - 2"


WALL AS
REQUIRED

11 1/2"

FURNACE
EXHAUSTS

SLOPE 1/4" MIN.

19' - 5"

B 02
02
5' - 1 1/2"

1' - 2 1/2"

DRYER VENTS

GFI

36' - 8 1/2"

216

17R @ 6.70"
16T @ 11"

1B

6' - 3 1/4"

STAIRS #2

AC-1

7' - 11 1/2"

4' - 3 1/2"

2
A6-1.4

4"

BATHROOM
EXHAUSTS

EF-3 KITCHEN
HOOD EXHAUST

3' - 8 3/4"

DN

7' - 10 3/4"

8"

3' - 1 1/2"

3A

17R @ 6.70"
16T @ 11"

A6-1.3
7' - 5"

8' - 1 1/4"

H.P.

3' - 10 3/4"

11 1/2"

A.1

4 3/4"

A.1

12' - 10 1/2"

11

1' - 3"

11 3/4"

4"

42" HT ALUMINUM
RAILING WITH
TEMPERED
GLASS PANELS

36" HT ALUMINUM
PANEL RAILING

A6-1.1
7' - 1 1/2"
1' - 6"

9' - 2"

5' - 10 1/2"

1' - 6"

5' - 6"

17' - 8"

8"

7' - 1"
14' - 2 1/2"
15' - 6 3/4"

39' - 1 1/4"
1

10.26.16
8"

DRAWN BY:

ROOF PLAN

A2-1.2

SCALE: 1/4" = 1'-0"

A2-1.2

TYPICAL FLOOR PLAN


SCALE: 1/4" = 1'-0"

FZM

APPROVED BY: G.C.N.


SCALE:

AS NOTED

DESCRIPTION:

TYPICAL FLOOR
AND ROOF PLANS

A5-1.1
2

ISSUED FOR PERMIT

SHEET NO.

A2-1.2

NEW PARAPET
40' - 0"

ALUMINUM
CLAD ROOF

ROOF
38' - 6"

BUILT UP WOOD COLUMN


WITH 1 x 6 BASE AND CAP

4th FLOOR CLG


37' - 2"
PRE-FAB CORNICE
1

2 T

HARDI PLANK PANEL SIDING


HARDI PLANK
PANEL SIDING

2" LIMESTONE
WINDOW SILL

4th FLOOR
29' - 0"

TYPICAL BALCONY WITH


POLISHED STEEL FASCIA
AND WOOD VENEER SOFFIT

3rd FLOOR CLG


27' - 8"

3 PANEL ALUMINUM PATIO


DOOR

2 T

2" LIMESTONE
WINDOW SILL

3rd FLOOR
19' - 6"
2nd FLOOR CLG
18' - 2"

PROJECT #

1634

DATE:

09.29.16

2 T

42" HT. ALUMINUM


RAILING WITH TEMPERED
GLASS PANELS

42" HT. ALUMINIM PANEL


RAILING -TYP

2" REVEAL
2nd FLOOR
10' - 0"

ALUMINUM CLAD
ENTRY CANOPY
1

2" LIMESTONE
WINDOW SILL

4" BRICK VENEER


T
1st FLOOR
6"
GRADE
0"

A.1 A

1
A5-1.1
NEW PARAPET
40' - 0"
ROOF
38' - 6"
4th FLOOR CLG
37' - 2"
PRE-FAB CORNICE

ALUMINUM
CLAD ROOF

10

HARDI PLANK
PANEL
SIDING

HARDI PLANK PANEL


SIDING
2" LIMESTONE
WINDOW SILL

4th FLOOR
29' - 0"
3rd FLOOR CLG
27' - 8"

10

TYPICAL BALCONY
POLISHED STEEL FASCIA
WOOD VENEER SOFFIT
2" LIMESTONE SILL

SOUTH ELEVATION
SCALE: 1/4" = 1'-0"

515 SUMMIT AVE.


PARK RIDGE, IL 60068

MULTY FAMILY BUILDING

FOR BIDDING ONLY, NOT FOR CONSTRUCTION

1st FLOOR CLG


8' - 8"

3rd FLOOR
19' - 6"
2nd FLOOR CLG
18' - 2"

10

1
42" HT. ALUMINUM
RAILING WITH TEMPERED
GLASS PANELS

2nd FLOOR
10' - 0"

ALUMINUM CLAD
ENTRY CANOPY

1st FLOOR CLG


8' - 8"
2" LIMESTONE SILL

4" BRICK VENEER

2
A5-1.1

EAST ELEVATION
SCALE: 1/4" = 1'-0"

10.26.16
DRAWN BY:

ISSUED FOR PERMIT


FZM

APPROVED BY: G.C.N.

1st FLOOR
6"
GRADE
0"

SCALE:

AS NOTED

DESCRIPTION:

SOUTH & EAST


ELEVATIONS

SHEET NO.

A5-1.1

4
5' - 11"

6' - 0"
3' - 0"

6' - 0"
3' - 0"

3' - 0"

3' - 0"
3' - 0"

6' - 0"
2 1/2"

ROOF
38' - 6"
4th FLOOR CLG
37' - 2"

7' - 0"

(2) CASEMENT
(2) AWNING

CASEMENT
AWNING

2" LIMESTONE SILL


11 T

1
HARDI PLANK
PANEL SIDING

2nd FLOOR
3rd FLOOR
4th FLOOR
4" BRICK VENEER

6' - 0"
2 1/2"

3' - 0"

3' - 0"

3' - 0"

4th FLOOR
29' - 0"

3' - 0"

9' - 7"

3rd FLOOR CLG


27' - 8"

FRENCH DOOR
(TEMPERED)

CASEMENT

(2) CASEMENT

STOREFRONT
(TEMPERED)

(2) CASEMENT

SLIDING GLASS DOOR TRIPLE PANE


(TEMPERED)

EMERGENCY ESCAPE
WINDOW SILL = 38"
CLEAR OPENING = 7.5 S.F.
CLEAR HEIGHT 42 7/8"
CLEAR WIDTH = 25 1/4"

WINDOW SCHEDULE

TYPICAL BALCONY WITH


POLISHED STEEL FASCIA
AND WOOD VENEER SOFFIT

1
3rd FLOOR
19' - 6"

1ST FLOOR

2nd FLOOR CLG


18' - 2"

CASEMENT
EMERGENCY ESCAPE
WINDOW SILL = 38"
CLEAR OPENING = 7.5 S.F.
CLEAR HEIGHT 42 7/8"
CLEAR WIDTH = 25 1/4"

42" HT. ALUMINUM


RAILING WITH TEMPERED
GLASS PANELS

SCALE: 1/4" = 1'-0"

11 T

1
7' - 0"

3' - 2"

7' - 0"

6' - 11 1/2"

4' - 0"

2 1/2"
6' - 9 1/2"

6' - 7"

4' - 0"

2 1/2"

2 1/2"

7' - 0"

7' - 0"

4' - 0"

(2) CASEMENT
(2) TRANSOM

2' - 3 1/2"

NEW PARAPET
40' - 0"

2 PANEL ALUMINUM
PATIO DOOR

2' - 0"

SLIDING GLASS DOOR


(TEMPERED)

3' - 0"

3' - 0"
6' - 9 1/2"
T

7' - 0"

5' - 11"
3' - 0"

4' - 0"

2' - 6"

2 1/2"

3' - 0"

10

3' - 2"

3' - 0"

11

7' - 0"

2' - 11 1/2"

2' - 0"

7' - 0"

6' - 11 1/2"

4' - 0"

PREFAB CORNICE

11 T

PROJECT #

1634

DATE:

09.29.16

ALUMINUM CLAD
ENTRY CANOPY
2nd FLOOR
10' - 0"

2" LIMESTONE SILL

1st FLOOR
6"
GRADE
0"

ALUMINUM
CLAD ROOF

PRE-FAB CORNICE

NEW PARAPET
40' - 0"

HARDI PLANK PANEL SIDING

ROOF
38' - 6"
4th FLOOR CLG
37' - 2"
HARDI PLANK PANEL SIDING
3

6
1

2" LIMESTONE
WINDOW SILL
TYPICAL BALCONY
POLISHED STEEL FASCIA
WOOD VENEER SOFFIT

7 T

BUILT UP WOOD COLUMN


WITH 1 x 6 BASE AND CAP

1
4th FLOOR
29' - 0"
3rd FLOOR CLG
27' - 8"

TYPICAL BALCONY WITH


POLISHED STEEL FASCIA
AND WOOD VENEER SOFFIT

6
8

8
7 T

A5-1.2

NORTH ELEVATION
SCALE: 1/4" = 1'-0"

515 SUMMIT AVE.


PARK RIDGE, IL 60068

MULTY FAMILY BUILDING

A A.1

FOR BIDDING ONLY, NOT FOR CONSTRUCTION

1st FLOOR CLG


8' - 8"

2" REVEAL
1
3rd FLOOR
19' - 6"

2nd FLOOR CLG


18' - 2"
42" HT. ALUMINUM RAILING
WITH TEMPERED GLASS
PANELS

42" HT. ALUMINUM


RAILING WITH TEMPERED
GLASS PANELS

7 T

1
2nd FLOOR
10' - 0"

ALUMINUM CLAD
ENTRY CANOPY

1st FLOOR CLG


8' - 8"

10.26.16

2" LIMESTONE SILL

4" BRICK VENEER

DRAWN BY:

ISSUED FOR PERMIT


FZM

APPROVED BY: G.C.N.


7

SCALE:

AS NOTED

DESCRIPTION:

NORTH AND WEST


ELEVATIONS

2
A5-1.2

WEST ELEVATION
SCALE: 1/4" = 1'-0"

1st FLOOR
6"
GRADE
0"

SHEET NO.

A5-1.2

A5-1.3
8

A5-1.3
8

A5-1.3

A5-1.3

A5-1.3

9' - 6"

9' - 6"

19' - 0"

A5-1.3

B 02
02

16'-0"x8'-0"
GARAGE DOOR

SCALE: 1/4" = 1'-0"

A5-1.3

1'-0"
40 YR ARCHITECTURAL ASPHALT
SHINGLES

6"

GARAGE FLOOR PLAN

1
A5-1.3

SCALE: 1/4" = 1'-0"

1'-0"
1'-0"

6"

6"

ALUMINUM GUTTERS AND


DOWN SPOUT
BOTTOM OF FASCIA
9' - 6"
14' - 11"

HARDIE PLANK
PANEL SIDING

HARDIE PLANK
PANEL SIDING
5

1' - 4 1/2"

1" REVEAL - TYP.

GRADE
0"

WINDOW HEADER
- SEE STRUCTURAL DRAWINGS

9' - 0 1/2"

SCALE: 1/4" = 1'-0"

1'-0"
40 YR ARCHITECTURAL ASPHALT
SHINGLES

GRADE
0"

GARAGE NORTH ELEVATION

4' - 0"

A5-1.3

6"

A5-1.3

GARAGE EAST ELEVATION


SCALE: 1/4" = 1'-0"

1'-0"

1'-0"
40 YR ARCHITECTURAL ASPHALT
SHINGLES

6"

ALUMINUM GUTTERS AND


DOWNSPOUT

1'-0"

6"

6"

ALUMINUM GUTTERS AND


DOWN SPOUT

14' - 11"

3' - 8"

BOTTOM OF FASCIA
9' - 6"
HARDIE PLANK
PANEL SIDING
1" REVEAL - TYP.

BOTTOM OF FASCIA
9' - 6"

HARDIE PLANK
PANEL SIDING
5

1" REVEAL - TYP.

1/2" ANCHOR BOLTS EMBED


7" MIN. @ 48" MIN. 2 PER PLATE

10.26.16
DRAWN BY:

4"

GRADE
0"

A5-1.3

SCALE: 1/4" = 1'-0"

6"

1" REVEAL - TYP.

TYPICAL WALL CONSTRUCTION 'HARD-I-BOARD' PANEL SIDING


1/2" RIGID INSULATION SHEATHING
W/TYVEK HOUSE WRAP
2" X 4" STUDS @ 16" O/C
5/8" GYP. BD.

A5-1.3

40 YR ARCHITECTURAL ASPHALT
SHINGLES

1' - 0"
A5-1.3

GARAGE WALL SECTION


SCALE: 1/2" = 1'-0"

ISSUED FOR PERMIT


FZM

APPROVED BY: G.C.N.


GRADE
0"

1' - 8"

(2) #5 CONT. REBAR

09.29.16

TO HOUSE PANEL

BOTTOM OF FASCIA
9' - 6"

1"X8" H ALUMINUM CLAD WD


FASCIA BOARD,
2" X 6" SUB-FASCIA
ALUMINUM GUTTER &
DOWNSPOUT
ALUMINUM FLASHING
BOTTOM OF FASCIA
9' - 6"
ALUM SOFFIT W/ INTEGRAL VENT

GARAGE ROOF PLAN

ALUMINUM GUTTERS AND


DOWN SPOUT
TYPICAL ROOF CONSTRUCTION:
ARCHITECTURAL ALPHALT SHINGLES
2 LAYERS 15# FELT PAPER
ICE AND WATER SHIELD AT 4' AROUND PERIMETER
5/8" OSB SHEATING W/ H-CLIPS
ROOF RAFTERS PER FRAMING PLAN
CEILING JOIST PER FRAMING PLAN
5/8" GYP. BD.

1'-0"

DATE:

FOR BIDDING ONLY, NOT FOR CONSTRUCTION

A5-1.3

1634

9' - 6"
19' - 0"

PROJECT #

1' - 6"

3' - 0"

9' - 6"

GARAGE FOUNDATION PLAN

A5-1.3

18' - 1"

19' - 0"

16' - 0"

1' - 6"

GFI

2x10's ROOF
RAFTERS @ 16" O.C.

6" / 1'-0"

1' - 6"

1' - 8"

3' - 4"

DOWN
SPOUT

1' - 4"

2x10 CEILING JOIST @ 16" O.C.

515 SUMMIT AVE.


PARK RIDGE, IL 60068

2-3 1/2" x14" PSL


W/2-2x4 AT EACH END

2x10's ROOF
RAFTERS @ 16" O.C.

16' - 0"

2x10's ROOF
RAFTERS @ 16" O.C.

MULTY FAMILY BUILDING

A5-1.3 7

1' - 0"

A5-1.3 7

35' - 1 1/4"

6" / 1'-0"
36' - 0"

1' - 0"

36' - 0"

5" CONCRETE SLAB W/6"x6"/6/6 WWF


ON 4" GRANULAR FILL
SLOPE AWAY MIN 1/8" PER FOOT

33' - 0"

16' - 0"
31' - 4"

6" / 1'-0"

16'-0"x8'-0"
GARAGE DOOR

1' - 8"

GFI

1' - 8"

2-3 1/2" x14" PSL


W/2-2x4 AT EACH END

2x10's ROOF
RAFTERS @ 16" O.C.

GFI

16' - 0"

DOWN
SPOUT
6" / 1'-0"

1' - 8"

1' - 6"

7
A5-1.3

GARAGE WEST ELEVATION


SCALE: 1/4" = 1'-0"

GRADE
0"

6
A5-1.3

GARAGE SOUTH ELEVATION


SCALE: 1/4" = 1'-0"

SCALE:

AS NOTED

DESCRIPTION:

GARAGE FLOOR
PLANS AND ELEVS

SHEET NO.

A5-1.3

NEW PARAPET
40' - 0"

ROOF
38' - 6"

1' - 2 1/4"
4' - 0"
3' - 0"
1' - 2 1/4"

40' - 0"

THRU WALL FLASHING @ EACH


FLOOR LEVEL, WINDOW / DOOR
HEAD AND SILL, TYP.

2nd FLOOR
10' - 0"

5/4" DECKING

1' - 2 1/4"

1' - 2 1/4"

1st FLOOR CLG


8' - 8"
BOND BEAM GROUTED SOLID (SEE
STRUCT SHTS FOR DETAILS)

9"

1' - 0"

9"

T/ FOOTING
-2' - 6"

1st FLOOR
6"
GRADE
0"
1 1/2" X 3' DEEP RIGID INSULATION
AROUND PERIMETER OF
FOUNDATION WITH PROTECTIVE
COVERING TO EXTEND 6" MIN
BELOW GRADE

STEEL LINTEL - SEE STRUCTURAL


DRAWINGS

4' - 0"

4' - 0"

1st FLOOR
6"
GRADE
0"

BOND BEAM GROUTED SOLID (SEE


STRUCT SHTS FOR DETAILS)
THRU WALL FLASHING @ EACH
FLOOR LEVEL, WINDOW / DOOR
HEAD AND SILL, TYP.

THRU WALL FLASHING @ EACH


FLOOR LEVEL, WINDOW / DOOR
HEAD AND SILL, TYP.
STEEL LINTEL - SEE STRUCTURAL
DRAWINGS

TYPICAL CONC.
SLAB
5" CONC. SLAB
W/6"x6"/ W2.1xW2.1
REINF. W/ 2" RIGID
INSUL (R-10) ON 5"
CA7 GRAVEL FILL ON
JETTED GROUND

1st FLOOR CLG


8' - 8"

4" CAST STONE SILL

TYPICAL CONC.
SLAB
5" CONC. SLAB
W/6"x6"/ W2.1xW2.1
REINF. W/ 2" RIGID
INSUL (R-10) ON 5"
CA7 GRAVEL FILL ON
JETTED GROUND

4
S-1

9"

1' - 0"

T/ FOOTING
-2' - 6"

2' - 6"

9"

TYPICAL EXTERIOR WALL CONSTRUCTION


(2 HR RATING UL# U906)
4" BRICK VENEER
W/ 1" AIR SPACE TIED TO
8" CONCRETE MASONRY UNITS
(SEE STRUCTURAL SHEETS FOR DETAILS)
VAPOR BARRIER
R-21 MIN BIOFOAM INSULATION
3 1/2" WD FURRING @ 24" OC
5/8" GYP BD
THRU WALL FLASHING @ EACH
FLOOR LEVEL, WINDOW / DOOR
HEAD AND SILL, TYP.
1st FLOOR
6"
GRADE
0"
1 1/2" X 3' DEEP RIGID INSULATION
AROUND PERIMETER OF
FOUNDATION WITH PROTECTIVE
COVERING TO EXTEND 6" MIN
BELOW GRADE

2' - 6"

T/ FOOTING
-2' - 6"

10.26.16
DRAWN BY:

A6-1.1

SECTION AT FRONT BALCONY


SCALE: 1/2" = 1'-0"

2
A6-1.1

SECTION AT BALCONY
SCALE: 1/2" = 1'-0"

1
A6-1.1

TYPICAL WALL SECTION


SCALE: 1/2" = 1'-0"

ISSUED FOR PERMIT


FZM

APPROVED BY: G.C.N.


SCALE:

AS NOTED

DESCRIPTION:

WALL SECTIONS

SHEET NO.

515 SUMMIT AVE.


PARK RIDGE, IL 60068

4" CAST STONE SILL

FOR BIDDING ONLY, NOT FOR CONSTRUCTION

7' - 0"

TYPICAL WALL CONSTRUCTION 4" BRICK VENEER W/


MAS. ANCHORS @ 24" O/C HOR. W/
1" AIR SPACE ON
1/2" RIGID INSULATION SHEATHING W/
TYVEK HOUSE WRAP
(1/2" CDX PLYWOOD 4' FROM
CORNERS)
R-21 BATT INSULATION
2" X 6" STUDS @ 16" O/C
5/8" GYP. BD.
3rd FLOOR
19' - 6"

2nd FLOOR CLG


18' - 2"
WINDOW HEADER AND LINTEL - SEE
STRUCTURAL DRAWINGS
THRU WALL FLASHING @ EACH
FLOOR LEVEL, WINDOW / DOOR
HEAD AND SILL, TYP.

1' - 2 1/4"

THRU WALL FLASHING @ EACH


FLOOR LEVEL, WINDOW / DOOR
HEAD AND SILL, TYP.

4" CAST STONE SILL


TYPICAL EXTERIOR WALL CONSTRUCTION
(2 HR RATING UL# U906)
4" BRICK VENEER
W/ 3/4" AIR SPACE TIED TO
8" CONCRETE MASONRY UNITS
(SEE STRUCTURAL SHEETS FOR DETAILS)
VAPOR BARRIER
R-11 MIN BIOFOAM INSULATION
1 1/2" WD FURRING @ 24" OC
5/8" GYP BD
THRU WALL FLASHING @ EACH
FLOOR LEVEL, WINDOW / DOOR
HEAD AND SILL, TYP.

09.29.16

THRU WALL FLASHING @ EACH


FLOOR LEVEL, WINDOW / DOOR
HEAD AND SILL, TYP.

TYPICAL FLOOR
CONSTRUCTION 3/4" T & G SUB-FLOOR
G & N TO FLOOR
JOIST PER FRAMING
PLAN R-38 BATT
INSULATION
5/8" GYP DRYWAL

4" CAST STONE SILL

FLOOR JOIST PER FRAMING PLANS


2nd FLOOR
10' - 0"

DATE:

MULTY FAMILY BUILDING

WOOD VENEER SOFFIT

THRU WALL FLASHING @


EACH FLOOR LEVEL,
WINDOW / DOOR HEAD
AND SILL, TYP.

1634

3rd FLOOR CLG


27' - 8"
WINDOW HEADER AND LINTEL - SEE
STRUCTURAL DRAWINGS
THRU WALL FLASHING @ EACH
FLOOR LEVEL, WINDOW / DOOR
HEAD AND SILL, TYP.

7' - 0"

40' - 0"

POLISHED STEEL FASCIA


OVER WOOD BEAM

PROJECT #

1' - 4"
8' - 2 1/4"

1' - 2 1/4"
1' - 2 1/4"

2nd FLOOR CLG


18' - 2"

DOOR HEADER AND


LINTEL - SEE
STRUCTURAL DRAWINGS

4" CAST STONE SILL


THRU WALL FLASHING @ EACH
FLOOR LEVEL, WINDOW / DOOR
HEAD AND SILL, TYP.
4th FLOOR
29' - 0"

2' - 6"

1 1/2" X 3' DEEP RIGID


INSULATION AROUND
PERIMETER OF
FOUNDATION WITH
PROTECTIVE COVERING
TO EXTEND 6" MIN BELOW
GRADE

THRU WALL FLASHING @ EACH


FLOOR LEVEL, WINDOW / DOOR
HEAD AND SILL, TYP.
3rd FLOOR
19' - 6"

TYPICAL FLOOR
CONSTRUCTION 3/4" T & G SUB-FLOOR
G & N TO FLOOR
JOIST PER FRAMING
PLAN R-38 BATT
INSULATION
5/8" GYP DRYWAL

1' - 0"

4" CAST STONE SILL


THRU WALL FLASHING
@ EACH FLOOR LEVEL,
WINDOW / DOOR HEAD
AND SILL, TYP.

TYPICAL WALL CONSTRUCTION 'HARD-I-BOARD' PANEL SIDING


1/2" RIGID INSULATION SHEATHING W/
TYVEK HOUSE WRAP
(1/2" OSB PLYWOOD 4' FROM
CORNERS)
R-21 BATT INSULATION
2" X 6" STUDS @ 16" O/C
5/8" GYP. BD.

TYPICAL FLOOR
CONSTRUCTION 3/4" T & G SUB-FLOOR
G & N TO FLOOR
JOIST PER FRAMING
PLAN R-38 BATT
INSULATION
5/8" GYP DRYWAL

3' - 0"

TYPICAL CONC.
SLAB
5" CONC. SLAB
W/6"x6"/ W2.1xW2.1
REINF. W/ 2" RIGID
INSUL (R-10) ON 5"
CA7 GRAVEL FILL ON
JETTED GROUND

TYPICAL EXTERIOR WALL CONSTRUCTION


(2 HR RATING UL# U906)
4" BRICK VENEER
W/ 3/4" AIR SPACE TIED TO
8" CONCRETE MASONRY UNITS
(SEE STRUCTURAL SHEETS FOR DETAILS)
VAPOR BARRIER
R-21 MIN BIOFOAM INSULATION
3 1/2" WD FURRING @ 24" OC
5/8" GYP BD

3' - 0"

7' - 0"

1' - 2 1/4"

1' - 4"

THRU WALL FLASHING


@ EACH FLOOR
LEVEL, WINDOW /
DOOR HEAD AND SILL,
TYP.

1st FLOOR CLG


8' - 8"

4th FLOOR CLG


37' - 2"

4" CAST STONE SILL

4" CAST STONE SILL

TYPICAL FLOOR
CONSTRUCTION 3/4" T & G SUB-FLOOR
G & N TO FLOOR
JOIST PER FRAMING
PLAN R-38 BATT
INSULATION
5/8" GYP DRYWAL

TYPICAL BALCONY FLOOR CONSTRUCTION


'DURADEK' MEMBRANE HEAT WELDED TO
METAL FLASHING 5/8"
PLYWOOD SHEATHING
FLOOR JOIST PER FRAMING PLAN
WOOD VENEER SOFFIT
2nd FLOOR
10' - 0"

BOND BEAM GROUTED


SOLID (SEE STRUCT
SHTS FOR DETAILS)
STEEL LINTEL - SEE
STRUCTURAL
DRAWINGS

8' - 2 1/4"

POLISHED STEEL FASCIA


OVER WOOD BEAM

4" CAST STONE SILL


THRU WALL FLASHING
@ EACH FLOOR LEVEL,
WINDOW / DOOR HEAD
AND SILL, TYP.

42" HT. ALUMINUM


RAILING WITH TEMPERED
GLASS PANELS

1' - 4"

TYPICAL FLOOR
CONSTRUCTION 3/4" T & G SUB-FLOOR
G & N TO FLOOR
JOIST PER FRAMING
PLAN R-38 BATT
INSULATION
5/8" GYP DRYWAL

2nd FLOOR CLG


18' - 2"

WOOD VENEER SOFFIT

TYPICAL WALL CONSTRUCTION 4" BRICK VENEER W/


MAS. ANCHORS @ 24" O/C HOR. W/
1" AIR SPACE ON
1/2" RIGID INSULATION SHEATHING
W/ TYVEK HOUSE WRAP
(1/2" CDX PLYWOOD 4' FROM
CORNERS)
R-21 BATT INSULATION
2" X 6" STUDS @ 16" O/C
5/8" GYP. BD.

8' - 2 1/4"

1' - 2 1/4"
7' - 0"

THRU WALL FLASHING @


EACH FLOOR LEVEL,
WINDOW / DOOR HEAD
AND SILL, TYP.

3rd FLOOR CLG


27' - 8"
DOOR HEADER AND LINTEL - SEE
STRUCTURAL DRAWINGS
THRU WALL FLASHING @ EACH
FLOOR LEVEL, WINDOW / DOOR
HEAD AND SILL, TYP.

1' - 4"

THRU WALL FLASHING @ EACH


FLOOR LEVEL, WINDOW / DOOR
HEAD AND SILL, TYP.

1' - 4"
8' - 2 1/4"

DOOR HEADER AND


LINTEL - SEE
STRUCTURAL DRAWINGS

THRU WALL FLASHING @ EACH


FLOOR LEVEL, WINDOW / DOOR
HEAD AND SILL, TYP.
4th FLOOR
29' - 0"

TYPICAL FLOOR
CONSTRUCTION 3/4" T & G SUB-FLOOR
G & N TO FLOOR
JOIST PER FRAMING
PLAN R-38 BATT
INSULATION
5/8" GYP DRYWAL

4" CAST STONE SILL

3rd FLOOR
19' - 6"

4" CAST STONE SILL

2' - 6"

TYPICAL FLOOR
CONSTRUCTION 3/4" T & G SUB-FLOOR
G & N TO FLOOR
JOIST PER FRAMING
PLAN R-38 BATT
INSULATION
5/8" GYP DRYWAL

8' - 2 1/4"

1' - 2 1/4"
7' - 0"

8' - 2 1/4"

42" HT. ALUMINUM


RAILING WITH TEMPERED
GLASS PANELS

7' - 0"

1' - 4"

3rd FLOOR CLG


27' - 8"
DOOR HEADER AND LINTEL - SEE
STRUCTURAL DRAWINGS
THRU WALL FLASHING @ EACH
FLOOR LEVEL, WINDOW / DOOR
HEAD AND SILL, TYP.
TYPICAL WALL CONSTRUCTION 4" BRICK VENEER W/
MAS. ANCHORS @ 24" O/C HOR. W/
1" AIR SPACE ON
1/2" RIGID INSULATION SHEATHING
W/ TYVEK HOUSE WRAP
(1/2" CDX PLYWOOD 4' FROM
CORNERS)
R-21 BATT INSULATION
2" X 6" STUDS @ 16" O/C
5/8" GYP. BD.

TYPICAL FLOOR
CONSTRUCTION 3/4" T & G SUB-FLOOR
G & N TO FLOOR
JOIST PER FRAMING
PLAN R-38 BATT
INSULATION
5/8" GYP DRYWAL

1' - 4"

4" CAST STONE SILL


THRU WALL FLASHING @ EACH
FLOOR LEVEL, WINDOW / DOOR
HEAD AND SILL, TYP.
4th FLOOR
29' - 0"

THRU WALL FLASHING


@ EACH FLOOR LEVEL,
WINDOW / DOOR HEAD
AND SILL, TYP.

TYPICAL WALL CONSTRUCTION 'HARD-I-BOARD' PANEL SIDING


1/2" RIGID INSULATION SHEATHING W/
TYVEK HOUSE WRAP
(1/2" OSB PLYWOOD 4' FROM
CORNERS)
R-21 BATT INSULATION
2" X 6" STUDS @ 16" O/C
5/8" GYP. BD.

1' - 0"

TYPICAL FLOOR
CONSTRUCTION 3/4" T & G SUB-FLOOR
G & N TO FLOOR
JOIST PER FRAMING
PLAN R-38 BATT
INSULATION
5/8" GYP DRYWAL

WINDOW HEADER - SEE


STRUCTURAL DRAWINGS
THRU WALL FLASHING @ EACH
FLOOR LEVEL, WINDOW / DOOR
HEAD AND SILL, TYP.

8' - 2 1/4"

8' - 2 1/4"
7' - 0"

8' - 2 1/4"

THRU WALL FLASHING


@ EACH FLOOR LEVEL,
WINDOW / DOOR HEAD
AND SILL, TYP.

8' - 2 1/4"

1' - 2 1/4"

TYPICAL WALL CONSTRUCTION 'HARD-I-BOARD' PANEL SIDING


1/2" RIGID INSULATION SHEATHING W/
TYVEK HOUSE WRAP
(1/2" OSB PLYWOOD 4' FROM
CORNERS)
R-21 BATT INSULATION
2" X 6" STUDS @ 16" O/C
5/8" GYP. BD.

NEW PARAPET
40' - 0"

4th FLOOR CLG


37' - 2"

DOOR HEADER - SEE


STRUCTURAL
DRAWINGS

7' - 0"

4th FLOOR CLG


37' - 2"

DOOR HEADER - SEE


STRUCTURAL
DRAWINGS

7' - 0"

1' - 2 1/4"

ROOF
38' - 6"

1' - 4"

NEW PARAPET
40' - 0"

A.1 A

8' - 2 1/4"

TYPICAL FLAT ROOF


CONSTRUCTION (UL # P522) - CLASS B
COVERING
EPDM ROOFING MEMBRANE
1 1/2" MIN RIGID INSULATION
1/4" SLOPE TO DRAIN W/ BUILT
WD FRAMING
5/8" PLYWOOD SHEATHING
ROOF JOISTS PER FRAMING
PLAN
R-38 MIN. BATT INSULATION
W/AIR BAFFLES
5/8" GYP BOARD

1' - 4"

TYPICAL FLAT ROOF


CONSTRUCTION (UL # P522) - CLASS B COVERING
EPDM ROOFING MEMBRANE
1 1/2" MIN RIGID INSULATION
1/4" SLOPE TO DRAIN W/ BUILT
WD FRAMING
5/8" PLYWOOD SHEATHING
ROOF JOISTS PER FRAMING
PLAN
R-38 MIN. BATT INSULATION
W/AIR BAFFLES
5/8" GYP BOARD

8' - 2 1/4"

TYPICAL FLAT ROOF


CONSTRUCTION (UL # P522) - CLASS B
COVERING
EPDM ROOFING MEMBRANE
1 1/2" MIN RIGID INSULATION
1/4" SLOPE TO DRAIN W/ BUILT
WD FRAMING
5/8" PLYWOOD SHEATHING
ROOF JOISTS PER FRAMING
PLAN
R-38 MIN. BATT INSULATION
W/AIR BAFFLES
5/8" GYP BOARD

A6-1.1

A.1 A
NEW PARAPET
40' - 0"
ROOF
38' - 6"
4th FLOOR CLG
37' - 2"

UNIT #4
4th FLOOR
29' - 0"
3rd FLOOR CLG
27' - 8"

UNIT #3

3rd FLOOR
19' - 6"
2nd FLOOR CLG
18' - 2"

STAIRS #1
UNIT #2

PROJECT #

1634

DATE:

09.29.16

2nd FLOOR
10' - 0"
1st FLOOR CLG
8' - 8"

1st FLOOR
6"
GRADE
0"

T/ FOOTING
-2' - 6"
NEW PARAPET
40' - 0"

4th FLOOR CLG


37' - 2"

SCALE: 1/4" = 1'-0"

UNIT 4

4th FLOOR
29' - 0"
3rd FLOOR CLG
27' - 8"

UNIT 3

3rd FLOOR
19' - 6"

515 SUMMIT AVE.


PARK RIDGE, IL 60068

A6-1.2

LONGITUDINAL BUILDING SECTION

MULTY FAMILY BUILDING

ROOF
38' - 6"

FOR BIDDING ONLY, NOT FOR CONSTRUCTION

UNIT #1

2nd FLOOR CLG


18' - 2"

UNIT 2

STAIRS #1

2nd FLOOR
10' - 0"
1st FLOOR CLG
8' - 8"

UNIT 1
10.26.16
DRAWN BY:
1st FLOOR
6"
GRADE
0"

T/ FOOTING
-2' - 6"

2
A6-1.2

TRANSVERSAL BUILDING SECTION


SCALE: 1/4" = 1'-0"

ISSUED FOR PERMIT


FZM

APPROVED BY: G.C.N.


SCALE:

AS NOTED

DESCRIPTION:

BUILDING
SECTIONS

SHEET NO.

A6-1.2

NEW PARAPET
40' - 0"

NEW PARAPET
40' - 0"

ROOF
38' - 6"
4th FLOOR CLG
37' - 2"

ROOF
38' - 6"
4th FLOOR CLG
37' - 2"

SD

HOLD 6'-8" CLEAR


OVERHEAD FROM
EDGE OF STEPS

1' - 0"

1' - 11"

5' - 3 1/4"

5' - 3 1/4"
1' - 0"

DN

3' - 5 1/2"

2nd FLOOR CLG


18' - 2"

3' - 6"

7T @ 11" = 6' - 5"

8T @ 11" = 7' - 4"

3' - 8"

PROJECT #

1634

DATE:

09.29.16

HOLD 6'-8" CLEAR


OVERHEAD FROM
EDGE OF STEPS
8 R @ 6.70" =
4' - 5 3/4"

1' - 11"

9 R @ 6.70" =
5' - 0 1/4"

2nd FLOOR CLG


18' - 2"

1' - 0"

2nd FLOOR
10' - 0"

1st FLOOR CLG


8' - 8"

1st FLOOR CLG


8' - 8"

8 R @ 6.70" =
4' - 5 3/4"

9 R @ 6.70" =
5' - 0 1/4"

2nd FLOOR
10' - 0"

2' - 10"

SCALE: 1/4" = 1'-0"

9 R @ 6.70" =
5' - 0 1/4"

2' - 10"

8 R @ 6.70" =
4' - 5 3/4"

3' - 6"

2' - 10"

1' - 0"

3' - 6"

STAIR #2 SECTION

HOLD 6'-8" CLEAR


OVERHEAD FROM
EDGE OF STEPS

1' - 11"

7T @ 11" = 6' - 5"

3' - 8"

1st FLOOR
6"
GRADE
0"
NOTE:
PROVIDE 5/8" TO THE
UNDERSIDE OF STAIRS

1
A6-1.3

STAIR #1 SECTION
SCALE: 1/4" = 1'-0"

1' - 0"

3' - 5 1/2"

3' - 8"

3' - 8"

1' - 11"

1' - 0"

3' - 5 1/2"

8T @ 11" = 7' - 4"

3' - 8"

HANDRAIL

7 T @ 11" = 6' - 5"

17R @ 6.70"

8 T @11" = 7' - 4"

HANDRAIL

HANDRAIL

17R @ 6.70"

8 T @ 11" = 7' - 4"

HANDRAIL

UP

1' - 11"

1' - 0"

7T @ 11" = 6' - 5"

3rd FLOOR
19' - 6"

3' - 4"

8T @ 11" = 7' - 4"

NOTE:
PROVIDE 5/8" TO THE
UNDERSIDE OF STAIRS

1' - 1 1/2"

1' - 11"

3rd FLOOR
19' - 6"

1st FLOOR
6"
GRADE
0"

3' - 5 1/2"

1' - 0"

2' - 10"
1' - 11"

A6-1.3

DN

3rd FLOOR CLG


27' - 8"

HOLD 6'-8" CLEAR


OVERHEAD FROM
EDGE OF STEPS

ROOF ACCESS
LADDER

3rd FLOOR CLG


27' - 8"

2' - 10"

2' - 10"

9 R @ 6.70" =
5' - 0 1/4"
8 R @ 6.70" =
4' - 5 3/4"

9 R @ 6.70" =
5' - 0 1/4"

8T @ 11" = 7' - 4"

SCALE: 1/2" = 1'-0"

ROOF ACCESS
HATCH 36" x 30"

4th FLOOR
29' - 0"

FOR BIDDING ONLY, NOT FOR CONSTRUCTION

A6-1.3

4th FLOOR
29' - 0"

HOLD 6'-8" CLEAR


OVERHEAD FROM
EDGE OF STEPS

1' - 11"

1' - 0"

515 SUMMIT AVE.


PARK RIDGE, IL 60068

SCALE: 1/2" = 1'-0"

STAIRS #1 - PARTIAL 1st FLR PLAN

8T @ 11" = 7' - 4"

MULTY FAMILY BUILDING

A6-1.3

1' - 0"

9 R @ 6.70" =
5' - 0 1/4"

215

STAIRS #1 - PARTIAL 2nd FLR PLAN

8T @ 11" = 7' - 4"

8 R @ 6.70" =
4' - 5 3/4"

STAIRS #1

8 R @ 6.70" =
4' - 5 3/4"

1' - 11"

HANDRAIL
1' - 0"

3' - 8"

1' - 11"

3' - 8"

1' - 11"

3' - 5 1/2"

HANDRAIL

3' - 5 1/2"

7 T @ 11" = 6' - 5"

17R @ 6.70"

3' - 5 1/2"

1' - 0"

3' - 5 1/2"

UP

7 T @ 11" = 6' - 5"

17R @ 6.70"

17R @ 6.70"

8 T @ 11" = 7' - 4"

HANDRAIL

UP

1' - 11"

HOLD 6'-8" CLEAR


OVERHEAD FROM
EDGE OF STEPS

2' - 10"

6' - 0 1/4"
1' - 11"

DN

HANDRAIL

1' - 0"

5' - 3 1/4"

SD

STAIRS #1

STAIRS #1

415

315

10.26.16
DRAWN BY:

ISSUED FOR PERMIT


FZM

APPROVED BY: G.C.N.

6
A6-1.3

STAIRS #1 - PARTIAL 4th FLR PLAN


SCALE: 1/2" = 1'-0"

5
A6-1.3

STAIRS #1 - PARTIAL 3rd FLR PLAN


SCALE: 1/2" = 1'-0"

SCALE:

AS NOTED

DESCRIPTION:

STAIR SECTIONS

SHEET NO.

A6-1.3

A.1

A.1
1' - 11"

HANDRAIL

8T @ 11" = 7' - 4"

1' - 0"

1' - 11"

17R @ 6.70"

9' - 7"

3' - 10"

HANDRAIL
DN
STAIRS #2

STAIRS #2

216

11' - 7 1/2"

11' - 7 1/2"

6' - 5"

3' - 7 1/4"
7 T @ 11" = 6' - 5"

115

5' - 3 3/4"

5' - 2 1/2"

17R @ 6.70"

1' - 0"

HANDRAIL

A6-1.4

SCALE: 1/2" = 1'-0"

STAIRS #2 - PARTIAL 1st FLR PLAN

1
A6-1.4

2
A

A.1

A.1

1' - 11"

1' - 0"

3' - 10"

STAIRS #2

3' - 9 1/2"

SCALE: 1/2" = 1'-0"

HANDRAIL

8 T @ 11" = 7' - 4"

3' - 9 1/2"

416

HANDRAIL

1' - 0"

8 T @ 11" = 7' - 4"

4' - 4 3/4"

17R @ 6.70"

DN

DN

STAIRS # 2

316

4' - 4 3/4"

17R @ 6.70"

7 T @ 11" = 6' - 5"

3' - 8"

UP
1' - 0"

4
A6-1.4

STAIRS #2 - PARTIAL 4th FLR PLAN


SCALE: 1/2" = 1'-0"

5' - 3 3/4"

17R @ 6.70"

42" GUARDRAIL

09.29.16

HANDRAIL

STAIRS #2 - PARTIAL 2nd FLR PLAN

1' - 11"

DATE:

1' - 11"

1634

1' - 11"

HANDRAIL

3
A6-1.4

STAIRS #2 - PARTIAL 3rd FLR PLAN


SCALE: 1/2" = 1'-0"

10.26.16
DRAWN BY:

FOR BIDDING ONLY, NOT FOR CONSTRUCTION

1' - 11"

PROJECT #

515 SUMMIT AVE.


PARK RIDGE, IL 60068

1' - 0"

UP

UP

MULTY FAMILY BUILDING

3' - 8"

17R @ 6.70"

ISSUED FOR PERMIT


FZM

APPROVED BY: G.C.N.


SCALE:

AS NOTED

DESCRIPTION:

PARTIAL STAIR
PLANS

SHEET NO.

A6-1.4

DOOR TYPE SCHEDULE


DOOR
HEAD

3/8" CONT SEALANT EA SIDE

HEAD

3/8" CONT SEALANT EA SIDE

HEAD

1/2" RIGID INSULATION


SHEATHING W/ TYVEK HOUSE
WRAP (1/2" CDX PLYWOOD 4'
FROM CORNERS)

2x4 WOOD STUDS, TYP.


2x6 @ PLUMBING WALL

PLAN

2x6 WOOD STUDS, TYP.

PLAN

5 1/2" R-21 BATT INSULATION

PLAN
(2) 5/8" GYP. BOARD
EA. SD. (FIRECODE CORE)

5/8" GYP. BOARD

5/8" GYP. BOARD

SOUND ATTENUATION
BLANKET
3/8" CONT. SEALANT
EACH SIDE

BASE

TYPE (#)

BRICK VENEER

WOOD STUD

3/8" CONT. SEALANT


EACH SIDE

BASE

STUD
SIZE
2x4
2x6
2x8

STUD
SPACING
16" OC
16" OC
16" OC

FIRE RATING /
TEST NO.
2 HR / U301
2 HR / U301
2 HR / U301

WALL
THK
6"
8"
10"

DTD.
NO.
A
B

STUD
SIZE
2x4
2x6

STUD
SPACING
24" OC
24" OC

FIRE RATING /
TEST NO.
1 HR / U309
1 HR / U309

01
02
03
04
05
06
07
08
09
10

WIDTH

HEIGHT

3'-0"
3'-0"
2'-10"
3'-0"
2'-8"
(2) 3'-0"
(2) 2'-6"
2'-6"
2'-4"
3'-0"

ELEV

7'-0"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
7'-0"

MATERIAL

B
A
A
A
A
C
C
A
A
D

METAL
WD/SC
WD/HC
WD/HC
WD/HC
WD/HC
WD/HC
WD/HC
WD/HC
METAL

FINISH

MATERIAL
METAL/HM
WD
WD
WD
WD
WD
WD
WD
WD
METAL/HM

PTD
PTD
PTD
PTD
PTD
PTD
PTD
PTD

FINISH

DETAILS

REMARKS

PTD
PTD
PTD
PTD
PTD
PTD
PTD
PTD

3/8" CONT. SEALANT


EACH SIDE

BASE

DOOR HARDWARE SCHEDULE

NOTE: TYPICAL WALL


NOT TAGGED ON PLAN

DTD.
NO.
A
B
C

FRAME

3/8" CONT SEALANT EA SIDE

SET (#)

WALL
THK
4 3/4"
6 3/4"

DTD.
NO.
A

STUD
SIZE
2x6

STUD

FIRE RATING /
TEST NO.

24" OC

WALL
THK
11 1/4"

01
02
03
04
05
06

HINGES

LOCKSET

1 1/2 PR. PRIME BUTT


1 1/2 PR. PRIME BUTT
1 1/2 PR. BB BUTT
1 1/2 PR. BB BUTT
1 1/2 PR. BB BUTT
1 1/2 PR. PRIME BUTT

KNOB/LEVER

PR. KEYED (OUT)


KEYED (OUT) BUTTON (IN)
PRIVACY
PASSAGE
PASSAGE
KEYED (OUT)

FINISH

LEVER W/PANIC
LEVER
LEVER
LEVER
PR KNOB - DUMMY
KNURLED LEVER

CLOSER STOP

CHROME - SATIN
CHROME - SATIN
CHROME - SATIN
CHROME - SATIN
CHROME - SATIN
CHROME - SATIN

YES
YES
NO
NO
NO
YES

WALL
WALL
WALL
WALL
WALL

WEATHERSTRIPPING

REMARKS

YES
NO
NO
NO
NO
YES

NOTE: ALL DOORS LEADING INTO HAZARDOUS ROOMS OR SPACES TO HAVE KNURLED HARDWARE.

PARTITION DETAIL 2 HR
1 1/2" = 1'-0"

TYPICAL PARTITION DETAIL


1 1/2" = 1'-0"

PROVIDE LEVER OPERATED HARDWARE THROUGHOUT THE BUILDING. NO DOOR KNOBS.

PARTITION DETAILS STUD BRICK


1 1/2" = 1'-0"

3
EXTERIOR WALL CAPPING

DOOR HARDWARE TO BE REVIEWED BY ARCHITECT, OWNER AND GENERAL CONTRACTOR BEFORE ORDERING.

EXTERIOR WALL CAPPING

PROJECT #

1634

DATE:

09.29.16

3/8" CONT SEALANT

HEAD

HEAD

CONT. SEALANT W/ BACKER ROD

HEAD

'HARD-I-BOARD' PANEL SIDING


BRICK VENEER
1/2" RIGID INSULATION SHEATHING W/
TYVEK HOUSE WRAP
HORIZ. JOINT REINF. 16" OC
1/2" OSB PLYWOOD SUBSTRATE
4' FROM CORNERS

PLAN

VERTICAL REINF. BAR SEE


STRUCTURAL SHTS

PLAN
2x6 WOOD STUDS, TYP.

CONT. SEALANT W/ BACKER ROD

CONTRACTOR TO USE THE ARCHITECT'S DOOR TYPE PLAN DESIGNATION IN ADDITION TO THE ROOM NUMBER
ON ALL SHOP DRAWING SCHEDULE SUBMITTALS.

RIGID INSULATION

DOOR THICKNESS SHALL BE 1 3/4" TYP. UNO.

'HARD-I-BOARD' PANEL SIDING

PROVIDE IDO LEVERS IN ALL HC ROOMS WHERE FLUSH MOUNTS ARE TYP.

TYVEK HOUSE WRAP

GLAZING AT LABELED DOORS TO BE FIRE-RESISTIVE, PROVIDE SAFETY GLAZING AT ALL NON-RATED DOORS.

HORIZ. JOINT REINF. 16" OC

ALL 20 MIN. DOORS TO BE SMOKE / DRAFT CONTROL DOORS.

VERTICAL REINF. BAR SEE


STRUCTURAL SHTS

PLAN

2 X4 WOOD STUDS

2 X4 WOOD STUDS

DOOR DESCRIPTION

5/8" GYP. BOARD

2 X2 WOOD STUDS

DOORS ARE DESIGNATED ON PLAN BY DOOR TYPES.

5 1/2" R-21 BATT INSULATION

5/8" GYP. BOARD

RIGID INSULATION
2 LAYERS 5/8" GYP. BOARD

GROUT @ REINFORCED
CELLS

BASE
3/8" CONT. SEALANT

GROUT @ REINFORCED
CELLS

BASE

DOOR DESIGNATION

STUD
SPACING
24" OC

FIRE RATING /
TEST NO.
2 HR / U349

PARTITION DETAILS STUD SIDING


1 1/2" = 1'-0"

WALL
THK
8"

DTD.
NO.
A
B

CMU
THK
6" CMU / 2X2
8" CMU / 2X2

24" OC
24" OC

PARTITION DETAIL CMU BRICK


1 1/2" = 1'-0"

FIRE RATING /
TEST NO.
2 HR / U906
2 HR / U906

WALL
THK
14 1/8"
16 1/8"

DTD.
NO.
A
B

CMU
THK
6" CMU / 2X2
8" CMU / 2X2

24" OC
24" OC

FIRE RATING /
TEST NO.
2 HR / U906
2 HR / U906

PARTITION DETAILS CMU SIDING


1 1/2" = 1'-0"

WALL
THK
11 1/2"
13 1/2"

A 01
01
DOOR HARDWARE SET

10.26.16
DRAWN BY:

515 SUMMIT AVE.


PARK RIDGE, IL 60068

STUD
SIZE
2x6

DOOR NUMBER

MULTY FAMILY BUILDING

DTD.
NO.
A

3 HR. (CLASS A)
90 MIN. (CLASS B)
60 MIN. (CLASS B)
45 MIN. (CLASS C)
20 MIN.
NON RATED

FIRE RATING
A
B
C
D
E
N

FIRE RATING LEGEND


H

BASE

FOR BIDDING ONLY, NOT FOR CONSTRUCTION

DOOR NOTES

ISSUED FOR PERMIT


FZM

APPROVED BY: G.C.N.


SCALE:

AS NOTED

DESCRIPTION:

PARTITION DTLS &


NOTES/ DOOR
SCHEDULE

SHEET NO.

A8-1.1

39' - 4"

4' - 8"

4" BRICK 8" BLOCK

16' - 1"

18' - 7"

COLUMN PER PLAN

PER PLAN

1' - 6"

8' - 4"

3
21' - 5 3/4"

17' - 10 1/2"

S-1

COLUMN CONNECTION SECTION

HSS 4X4X3/8 COLUMN

SCALE: 3/4" = 1'-0"

S-1

1' - 0"

4' - 3"

3
1' - 0"

8' - 2"

2' - 6"

4' - 0"

HSS 4X4X3/8 COLUMN

2' - 6"

1634

DATE:

09.29.16

FOOTING DETAIL

S-1

SCALE: 3/4" = 1'-0"


DIA 1/2" x 10" L. ANCHOR
BOLTS @ 4' O.C. MIN. 2 PER
PLATE
REINFORCEMENT PER PLAN

5" CONCRETE SLAB W/ 6x6


W2.9xW2.9 WWF

#4 BAR @ 12" O.C.


X

4' - 0"

2- #4 BARS
CONTINUOUS
6"

6"

6"

L1

1' - 0"

BEARING WALL SECTION

3' - 6"

6"

50' - 8"

1' - 0"

HSS 4X4X3/8 COLUMN


67' - 0"

HSS 4X4X3/8 COLUMN


2' - 6"

SCALE: 3/4" = 1'-0"

S-1

CONTROL JOIST @ 15'-0"


O.C. MAX. (TYP.)

5' - 11"

2' - 6"
L2

2' - 6"
1' - 6"

L1

16' - 10 1/2"

2' - 6"

UP

1' - 8"

1' - 6"

1' - 6"

4' - 0"

1' - 8"

4' - 0"
HSS 4X4X3/8 COLUMN

2' - 6"

21' - 5"

MARK

17' - 11"
L1

7' - 1 1/2"

ALLOWABLE SPANS AND SUPPORTS FOR HEADER OPENINGS

L1

SIZE OF HEADER NO STORY ABOVE ONE STORY ABOVE TRIMMERS/ JACK STUDS

HSS 4X4X3/8 COLUMN

H7

10'-0"

8'-0"

(2) 2" X 4"

3 1/2" X 11 7/8"*

14'-0"

10'-0"

(2) 2" X 4"

12'-0"

(3) 2" X 4"

3 1/2" X 14"*

16'-3"

3 1/2" X 18"*

18'-3"

16'-3"

(3) 2" X 4"

5 1/4" X 14"*

18'-3"

14'-0"

(3) 2" X 4"

7" X 14"*

18'-3"

16'-3"

(3) 2" X 4"

C
L1

6"

9' - 2"

5' - 10 1/2"

1' - 6"

L1

5' - 3"

17' - 4 3/4"
23' - 3 1/4"

LINTEL SCHEDULE
SECTION SIZE

2' - 6"

2' - 0"

L1

NOTE:
BASED ON THE SIZING TABLES PROVIDED BY TRUS JOIST IN HEADER AND COLUMN SPECIFIER'S GUIDE
PARAMETERS USED: ROOF LOAD: SNOW AREA 115%, 40LL + 15DL, HOUSE WIDTH: 24'
* DENOTES A SPECIFIC MICROLLAM SIZE

MARK

L1

2' - 6"

H6

3 1/2" X 9 1/4"*

6"

H5

(1) 2" X 4"

2' - 0"

H4

<8'-0"

6"

H3

<8'-0"

6' - 7"

H2

(2) 2" X 12"

5"

H1

2' - 6"

L2

7' - 0"

1st FLOOR
6"

1' - 6 3/4"

7' - 6"

STUD WALL PER PLAN

9' - 10 1/4"

L2

67' - 0"

4
S-1

PROJECT #

FOR BIDDING ONLY, NOT FOR CONSTRUCTION

T/ FOOTING
-2' - 6"

L1

COMPACTED FILL PER


GEOTECHNICAL ENGINEER

515 SUMMIT AVE.


PARK RIDGE, IL 60068

#5 @ 12" O.C. BOTH WAYS

L1

MIN BEARING
PREASURE OF
3000 PSF
REQUIRED. TO BE
VERIFIED BY
GEOTECHNICAL
ENGINEER
2

MULTY FAMILY BUILDING

#4 @ 12" O.C.

1' - 6 3/4"

36' - 8 1/2"

2'-6"

UP

24' - 4 1/2"

#4 @ 12" O.C.
2'-6"

6x6 W2.9xW2.9 WWF


#4 @ 18" O.C.

1st FLOOR
6"

SLAB PER PLAN

1' - 8"

17' - 4 3/4"

GRADE
0"

1/2" CONT. VOLCLAY


WATERSTOP

L1

2' - 6"

#4 @ 18" O.C.
EITHER SIDE

1st FLOOR
6"

4- #8 BARS @12"
O.C. EACH WAY

2' - 6"

1' - 0"

(4) #4 CONTINUOUS

4- 3/4" DIA HOOKED A. BOLTS

1' - 8"

1/4"
1-1/4" PLATE

#4 @ 18" O.C.

1' - 0"

A.1

L1

L1

FILL SOLID W/ GROUT

FIRST FLOOR SLAB

2' - 6"

TRUSS TYPE REINFORCEMENT


EVERY 2 COURSES

SLIPCE LENGHT

2' - 6" MIN.

L2
2' - 6"

L1

16' - 0 3/4"
39' - 4"

MATERIAL

L1

3 1/2" X 3 1/2" X 3/8"

L2

W8x10 + 3/8" PLATE

A-992 WF AND A-36 GRADE B CARBON STEEL

L3

2-2x12 + L 6" X 3 1/2" X 3/8"

A-36 GRADE B CARBON STEEL

L4

2-1 3/4" x 11 1/4" LVL + 6" X 3 1/2" X 3/8" A-36 GRADE B CARBON STEEL

A-36 GRADE B CARBON STEEL

NOTE:
*
LONG LEG OF THE ANGLE SHALL BE PLACED IN THE VERTICAL POSITION
STEEL ANGLES TO HAVE MIN. 6" BEARING, EACH SIDE
**
FOR CONTINUOUS SPANS, ANCHOR STEEL ANGLES TO DOUBLE STUD WALL FRAMING
W/(2) 7/16" X 4" LAG SCREWS @ 16" O/C
***
MAX HEIGHT OF MASONRY VENEER ABOVE CONTINUOUS ANGLE NOT TO EXCEED 12'-8"

1
S-1

METAL CONNECTORS

FOUNDATION AND FIRST FLOOR FRAMING


PLAN

ITEM

SST MODEL #

USP MODEL #

GAGE

INSTALLATION HARDWARE

SINGLE JOIST HANGER

LUS2xxZ or SS

JUS2xxTZ or SS

18

4 - 10d (JOIST), 8 - 10d (HEADER)

SCALE: 1/4" = 1'-0"

DOUBLE JOIST HANGER

LUS2xx-2Z or SS

JUS2xx-2TZ or SS

18

6 - 16d (JOIST), 8 - 16d (HEADER)

METAL ANGLE 1

L90Z

AC9 TZ

16

10 - 10d, 5 EA LEG

METAL ANGLE 2

A23Z

A3 TZ

18

8 - 10d x 1 1/2", 4 EA LEG

METAL ANGLE 3

TA9Z or KT

SCA9 TZ

12

5 - 1/4" DIA x 1 1/2" WD SCREW

APPROVED BY: G.C.N.

COLUMN BASE, 6x6 POST 1

CBSQ66-SDS2 HDG

CBSQ66-SDS2 TZ

12

14 - 1/4" DIA x 2" WD SCREW

SCALE:

AS NOTED

COLUMN BASE, 6x6 POST 2

ABW66Z

12

12 - 10d

POST BASE, RAILING POST

PBS44A HDG

WAS44 TZ

12

14 - 16d, 2 - 1/2" DIA BOLTS

DESCRIPTION:

METAL STRAP

MSTA12Z or SS

MSTA12TZ or SS

18

10 - 10d

POST BASE PLATE

CPS 4

CPB 44

4 - 10d

FOUNDATION PLAN
FIRST FLOOR
FRAMING

NOTE: Use smaller length nails with specified penny weight.


SST - Simpson Strong Tie; USP - United Steel Products
HDG- Hot Dipped Galvanized, SS- Stainless Steel
Z- Z MAX Galvanized (G-185), TZ- Triple Zinc Galvanized (G-185)

10.26.16
DRAWN BY:

SHEET NO.

ISSUED FOR PERMIT


FZM

S-1

38' - 9 1/2"
4' - 7 1/2"

39' - 4"

16' - 1 1/2"

18' - 0 1/2"

4' - 10 3/4"

15' - 10 1/4"

18' - 7"

H1

L4

L3
H1

1' - 3"

A
A.1

8' - 1 1/4"

8' - 4 1/2"

DN

H1

2x6 @ 16" O.C. BEARING


WALL STUDS BLOCKED @
THIRD POINTS

H1

2-1 3/4" x 14" LVL

H1
DN

L3

2-1 3/4" x 14" LVL

UP

L3

2x8's RUN THROUGH JOIST

A.1

H1

11 1/2"

H1

H1

3' - 6"

2-2 x 10's

2-1 3/4" x 14" LVL

2x6 @ 16" O.C. BEARING


WALL STUDS BLOCKED @
THIRD POINTS

H1

L3

L4

H1

2-1 3/4" x 14" LVL

4x4 PSL POST

1634

DATE:

09.29.16

36' - 10 1/2"

HSS 4X4X3/8 COLUMN

35' - 10 3/4"

3 1/2" x 11 1/4"
2.0E PSL

4x4 PSL POST

PROJECT #

HSS 4X4X3/8 COLUMN

L4

66' - 9 1/4"

2-1 3/4" x 14" LVL


UP

2-1 3/4" x 14" LVL

DN

H1

H2

L3

4x4 PSL POST

L4

2x12 LEDGER

HSS 4X4X3/8 COLUMN


H1

23' - 10 3/4"

H1

2-1 3/4" x 14" LVL

H1

2-1 3/4" x 14" LVL


23' - 10 3/4"

3 1/2" x 11 1/4" 2.0E PSL

4x4 PSL POST

FOR BIDDING ONLY, NOT FOR CONSTRUCTION

H1

515 SUMMIT AVE.


PARK RIDGE, IL 60068

2x6 @ 16" O.C. BEARING


WALL STUDS BLOCKED @
THIRD POINTS

MULTY FAMILY BUILDING

HSS 4X4X3/8 COLUMN

6' - 0"

L3

L3

DN

14" OPEN WEB TRUSS @ 16" O.C.

2-1 3/4" x 14" LVL

HSS 4X4X3/8 COLUMN

2-1 3/4" x 14" LVL

H1

H1

14" OPEN WEB TRUSS @ 16" O.C.

2x6 @ 16" O.C. BEARING


WALL STUDS BLOCKED @
THIRD POINTS

50' - 8"

4x4 PSL POST

6' - 8 1/4"

H1

66' - 5 3/4"

14" OPEN WEB TRUSS @ 16" O.C.

4x4 PSL POST


3 1/2" x 11 1/4"
2.0E PSL

14" OPEN WEB TRUSS @ 16" O.C.

50' - 1 1/2"

H1

HSS 4X4X3/8 COLUMN

2 x 12 LEDGER
L3

H1

D
2-2x12's

H1

2-2 x 12's

2x10 ROOF JOIST @ 16" O.C.

6' - 9 1/4"

2-2x12's

7' - 0 1/2"

H1

H1

2-2 x 12's

H1

H1
2x12 FLOOR JOIST @ 16" O.C.

10.26.16
2
S-2

ISSUED FOR PERMIT

ROOF FRAMING PLAN

DRAWN BY:

SCALE: 1/4" = 1'-0"

APPROVED BY: G.C.N.

FZM

SCALE:

AS NOTED

DESCRIPTION:

2nd FLOOR & ROOF


FRAMING PLANS

SHEET NO.

S-2

MECHANICAL NOTES

ALL SUPPLY REGISTERS SHALL BE 4" x 10" GRILLS WITH


DAMPERS (TYP.).
ALL DUCT WORK TO BE 26 GA. SHEET METAL.

6)

ALL REFRIGERATION LINES TO BE TYPE "K" COPPER. REMOVE ALL


EXPANSION VALVES AND CONNECTIONS FROM AIR STREAM.

7)

PROVIDE 3/8" SAFETY VALVE LOCATED ON CONDENSER AND SET


FOR 500 lb. PRESSURE.

8)

9)
10)
11)

STAIRS #2

VENT THRU ROOF


STORAGE

4X10 S/A
110 CFM

FD

BEDROOM 3

208

15)

209

4X10 S/A
50 CFM

17)

DUCTWORK WILL BE INSTALLED IN COMPLIANCE WITH THE ACCA


MANUAL "D".

18)

FIREPLACE SHALL BE PROVIDED WITH MAKE UP AIR.

19)

SUCTION AND LIQUID LINE SETS OVER 79FT MAY REQUIRE A SIZE UP.
FIELD VERIFY DISTANCE AND MANUFACTURER RECOMMENDED
INSTALLATION REQUIREMENTS.

WIC

108

VENT THRU ROOF


ELECTRICAL RM

HALL

2)

ALL OUTDOOR AIR INTAKES AND EXHAUSTS SHALL HAVE


AUTOMATIC OR GRAVITY DAMPERS THAT CLOSE WHEN THE
VENTILATION SYSTEM IS NO WORKING (R403.5)

3)

DUCT TESTING IS REQUIRED IF ANY DUCTS ARE NOT LOCATED


ENTIRELY WITHIN THE BUILDING THERMAL ENVELOPE

4)

DUCT TESTING IS REQUIRED IF ANY DUCTS ARE NOT LOCATED


ENTIRELY WITHIN THE BUILDING THERMAL ENVELOPE

EF-2

REF.

4X10 S/A
50 CFM

206

AN APPROVED PARTY, INDEPENDENT FROM THE INSTALLER OF THE


INSULATION SHALL INSPECT THE AIR BARRIER AND INSULATION.
THE DOCUMENT SHALL PROVIDE A DUCT AIR LEAKAGE TEST
RESULTING IN A LEAKAGE RATE LESS THAN 4 CFM PER 100 SF.
THE WRITTEN TEST REPORT SHALL BE SIGNED AND SUBMITTED
PRIOR TO OCCUPANCY APPROVAL. (R403.2.2)"

6)

PROVIDE DUCT SEALANT (WELDS AND/OR SPRAY FOAM)(R403.2)

7)

HEATED WATER PIPES SHALL BE INSULATED.

MASTER
BATHROOM

DW

REF.
VENT THRU ROOF

KITCHEN

MECH CLOSET

KITCHEN

203

211

103

VENT THRU
ROOF

WH

MECH CLOSET

110

106

207

4X10
EF-1S/A
50 CFM

4X10 S/A
100 CFM

4X10 S/A
100 CFM
4X10 S/A
153 CFM

4x10 R/A
100 CFM

LIVING/ DINING

101

4x10 R/A
237 CFM

4x10 R/A
153 CFM

LIVING / DINING

STORAGE

STORAGE

201

FD

113

214

4X10 S/A
126 CFM

4x10 R/A
236 CFM

4x10 R/A
251 CFM

BEDROOM 2

4X10 S/A
125 CFM
4x10 R/A
128 CFM

104

4x10 R/A
106 CFM

BEDROOM 2

204

4X10 S/A
128 CFM

M1-1.1

09.29.16

BATH 2

4x10 R/A
100 CFM

4X10 S/A
158 CFM

DATE:

4X10 S/A
50 CFM

BATH 2

213

4X10 S/A
158 CFM

1634

105

F-1

EF-1

VESTIBULE

PROJECT #

FD

EF-3

4X10 S/A
50 CFM

EF-2

4X10 S/A
50 CFM

FD

WH

4x10 R/A
50 CFM

VENT THRU ROOF

F-1

5)

109

117

MASTER
BATHROOM

ENERGY CONSERVATION NOTES


CONTRACTOR SHALL PROVIDE A WHOLE-HOUSE AIR LEAKAGE TEST
RESULTING IN A LEAKAGE RATE LESS THAN 3 AIR CHANGES PER
HOUR. THE WRITTEN TEST REPORT SHALL BE SIGNED AND
SUBMITTED PRIOR TO OCCUPANCY APPROVAL."

HALL

SPRINKLER RM

210

4X10 S/A
157 CFM

1)

FD

116

4x10 R/A
110 CFM

VENT THRU ROOF

THESE DRAWINGS REPRESENT THE GENERAL ARRANGEMENT OF THE


FLOOR STRUCTURE, HVAC AND PLUMBING LAY-OUT AND SHALL
NOT RELIEVE THE SUBCONTRACTORS OF THE RESPONSIBILITY FOR
CONFORMITY WITH THE REQUIREMENTS AS SHOWN ON THE
PLANS, SPECIFICATIONS, LOCAL CODES AND ORDINANCES. FLOOR
TRUSS SHOP DRAWINGS SHALL TAKE PRECEDENCE OVERTHESE
DRAWINGS. THE CARPENTER CONTRACTOR SHALL COORDINATE THE
FINAL LAY- OUT OF ALL TRUSSES WITH THE PLUMBING AND HVAC
CONTRACTORS AS TO ALLOW THEIR WORK TO BE COMPLETED
WITHOUT STRUCTURAL MODIFICATION TO TRUSSES. ALL CUTTING OF
HOLES THRU ANY TRUSS SHALL BE APPROVED BY THE TRUSS
MANUFACTURER OR HIS ENGINEER.
THERMOSTATS TO BE PROGRAMMABLE TYPE

4x10 R/A
152 CFM

4X10 S/A
61 CFM

WIC

4x10 R/A
50 CFM

INSULATE ALL DUCTWORK LOCATED IN CANTILEVERS, GARAGES


AND ATTIC SPACES (AND OTHER UNHEATED AREAS) OUTSIDE OF
THE THERMAL ENVELOPE WITH A MIN R-8.

16)

107
FD

VENT THRU ROOF

THIS CONTRACTOR SHALL COORDINATE WITH THE CARPENTRY


CONTRACTOR FOR THE HEADERING OFF OF ANY STUDS WHICH NEED
TO BE CUT TO ALLOW FOR VERTICAL OR HORIZONTAL DUCTWORK
RUNS. HOLES CUT OR DRILLED IN TOPS OF
BEARING PARTITIONS
SHALL NOT BE ALLOWED UNLESS APPROVED BY THE ENGINEER IN
CHARGE.

PLUMBING, ELECTRICAL, AND HVAC CONTRACTORS SHALL VERIFY


ALL FLUE CHASES AND EQUIPMENT LOCATIONS AND REPORT ANY
DISCREPANCIES OR CONFLICTS TO THE ARCHITECT PRIOR TO
SUBMITTING HIS BID. UNLESS THE ARCHITECT AND GENERAL
CONTRACTOR ARE NOTIFIED PRIOR TO CONSTRUCTION, ALL
CORRECTIVE MEASURES WILL BE MADE BY THE SUBCONTRACTORS
AT NO ADDITIONAL COST TO THE OWNER.

4x10 R/A
183 CFM

205

HEATING CONTRACTOR TO VERIFY ALL HEAT LOSS CALCULATIONS,


FURNACE AND A/C SIZES, AND C.F.M. SUPPLIED OR RETURNED.

14)

4X10 S/A
50 CFM
LAUNDRY /
MUDROOM

118

LAUNDRY /
MUDROOM

NOISE LEVELS FOR MECHANICAL EQUIPMENT NOT TO EXCEED 55 dbs


AT LOT LINE.

FLOOR REGISTERS SHALL BE NO MORE THAN 9" FROM ALL WALLS.

102

202

VENT THRU ROOF

PROVIDE A PAD FOR CONDENSING UNIT LOCATED IN YARDS AND OR


A CURB MOUNT (WITH FLASHING) WHEN MOUNTED ON THE ROOF OR
DECK.

13)

MASTER
BEDROOM

115
4x10 R/A
50 CFM

MASTER
BEDROOM

EF-3

12)

STAIRS #2

216
4x10 R/A
50 CFM

HEATING CONTRACTOR TO VERIFY DUCT CHASE, SOFFIT SIZE


AND LOCATION.

4X10 S/A
51 CFM

4X10 S/A
50 CFM

5)

4X10 S/A
51 CFM

4X10 S/A
50 CFM

4)

4X10 S/A
61 CFM

TYPICAL FLOOR MECHANICAL PLAN


SCALE: 1/4" = 1'-0"

FOR BIDDING ONLY, NOT FOR CONSTRUCTION

3)

4X10 S/A
61 CFM

515 SUMMIT AVE.


PARK RIDGE, IL 60068

PROVIDE HIGH AND LOW RETURN GRILLS WITH DAMPER


CONTROLS AS INDICATED.

MULTY FAMILY BUILDING

2)

LOCATE BATHROOM SUPPLY REGISTERS IN WALL, ABOVE BASE


BOARD.

DW

1)

4X10 S/A
106 CFM

1
M1-1.1

1st FLOOR MECHANICAL PLAN


SCALE: 1/4" = 1'-0"

ENERGY CONSERVATION NOTES (CONT.)


8)

9)

10)

THE INSULATION INSTALLER SHALL SIGN, DATE, AND POST THE CERTIFICATE LISTING THE
PREDOMINANT INSULATION VALUE IN A CONSPICUOUS LOCATION IN THE ATTIC. BLOWN OR SPRAYED
ROOF/CEILING INSULATION THICKNESS SHALL BE INDENTIFIED IN WRITTEN INCHES, AFFIXED TO THE
TRUSS OR JOISTS EVERY 300 FEET FOR INSPECTION (R303.1.1.1 & R403.) THIS SHALL BE POSTED
PRIOR TO THE INSULATION INSPECTION."
CONTRACTOR SHALL POST ON THE ELECTRIC DISTRIBUTION PANEL A PERMANENT CERTIFICATE.
THE CERTIFICATE SHALL LIST THE PREDOMINANT INSULATION VALUE, EACH PIECE OF THE BUILDING
THERMAL ENVELOPE, R-VALUES OF INSULATION INSTALLED, U-FACTORS OF THE WINDOWS, RVALUES OF DUCTS IN UNCONDITIONED SPACES, AND TYPES AND EFFICIENCIES OF HEATING COOLING
AND WATER HEATING EQUIPMENT. (R303.1.1 & R401.3) THIS SHALL BE POSTED PRIOR TO THE
INSULATION INSPECTION."
THIS PROJECT MUST MEET ENERGY CODE REQUIREMENTS FOR CLIMATE ZONE 5.

10.26.16
DRAWN BY:

ISSUED FOR PERMIT


FZM

APPROVED BY: G.C.N.


SCALE:

AS NOTED

DESCRIPTION:

1st & TYP FLR MECH


PLANS

SHEET NO.

M1-1.1

1
FURNACE SCHEDULE
MFG

MODEL

CFM

BTUH Input

F-1

RHEEM

RGGE-09EZCMS

1195

90000

83160

Motor (Hp)

Motor (Amps)

12

COMMENTS

A.1
H.P.

MARK

BTUH
Output

B
BATHROOM
EXHAUSTS
DRYER VENTS
1

R1
5' -

0"

A6-1.1

HEAT LOSS CALCULATION


HEAT PROVIDED

Level

COMMENTS

101
102
103
104
105
106
107
108
109
110
111
112
114
115

409 SF
250 SF
241 SF
172 SF
109 SF
48 SF
58 SF
41 SF
50 SF
25 SF
86 SF
0 SF
50 SF
113 SF

14321
8756
8449
6022
3801
1696
0
0
1751
0
3011
0
1741
3945

146
89
86
61
50
50
0
0
50
0
50
0
50
50

251
152
153
106
50
50
0
0
50
0
50
0
50
50

17436
10594
10645
7388
4583
2040
0
0
2457
0
2633
0
3208
4607

1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR

F-1
F-1
F-1
F-1
F-1
F-1
F-1
F-1
F-1
F-1
F-1
F-1
F-1
F-1

201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216

425 SF
263 SF
247 SF
183 SF
155 SF
112 SF
51 SF
58 SF
43 SF
63 SF
25 SF
0 SF
84 SF
61 SF
78 SF
120 SF
3623 SF
3623 SF

14891
9200
8636
6409
5429
3933
1772
0
0
2221
0
0
2950
0
2744
4213
115893
115893

152
94
88
65
55
50
50
0
0
50
0
0
50
0
50
50
1438
1438

301
183
172
111
128
50
50
0
0
50
0
0
50
0
50
50
2158
2158

16906
10271
9659
7163
6194
4444
1978
0
0
2382
0
0
3138
0
3079
4467
135272
135272

2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR

F-1
F-1
F-1
F-1
F-1
F-1
F-1
F-1
F-1
F-1
F-1
F-1
F-1
F-1
F-1
F-1

FURNACE INTAKE
FURNACE
EXHAUSTS

EF-3 KITCHEN
HOOD EXHAUST

AC-1

AC-1

45 DOWN

12"

AC-1

2 1/2"
1/2" AROUND 3 SIDES.
2'X2' WOOD.

FILL VOID IN CURB W/ FIBERGLASS


INSULATION.

ROOF ACCESS
HATCH

ROOFING
MATERIAL.
REFRIGERANT LINES TO CONDENSER.
CANTOUR BY ROOFING CONTRACTOR.

REFRIGERANT HOOD
NO TO SCALE

SLOPE 1/4" MIN.

REMOVABLE HOOD DESIGNED FOR


ACCESS TO DRYER CLEAN OUT

MULTY FAMILY BUILDING

2" LIP TURNED


DOWN

LIGHT & VENTILATION SCHEDULE

SLOPE 1/4" MIN.

NO

AREA

101
102
103
104
105
106
107
108
109
110
111
113
114
115
116
117
118

409 SF
250 SF
241 SF
172 SF
109 SF
48 SF
58 SF
41 SF
50 SF
25 SF
86 SF
57 SF
50 SF
113 SF
25 SF
60 SF
84 SF

32.7 SF
20.0 SF
19.3 SF
13.8 SF

LIVING / DINING
201
MASTER BEDROOM
202
KITCHEN
203
BEDROOM 2
204
BEDROOM 3
205
MASTER BATHROOM
206
BATH 2
207
LAUNDRY / MUDROOM
208
WIC
209
HALL
210
MECH CLOSET
211
VESTIBULE
213
STORAGE
214
STAIRS #1
215
STAIRS #2
216
2nd FLOOR - 3rd and 4th FLOORS SIMILAR

425 SF
263 SF
247 SF
183 SF
155 SF
112 SF
51 SF
58 SF
43 SF
63 SF
25 SF
84 SF
61 SF
78 SF
120 SF

34.0 SF
21.0 SF
19.7 SF
14.7 SF
12.4 SF

STAIRS #1
STAIRS # 2
3rd FLOOR

78 SF
120 SF

LIVING/ DINING
MASTER BEDROOM
KITCHEN
BEDROOM 2
MASTER BATHROOM
BATH 2
LAUNDRY / MUDROOM
WIC
HALL
MECH CLOSET
LOBBY
STORAGE
STAIRS #1
STAIRS #2
ELECTRICAL RM
SPRINKLER RM
STORAGE
1st FLOOR

STAIRS #1
STAIRS #2
4th FLOOR

315
316

415
416

160 SF
120 SF

16.4 SF
10.0 SF
9.7 SF
6.9 SF

59.5 SF
50.4 SF
5.9 SF
33.6 SF

59.5 SF
56.4 SF
5.9 SF
33.6 SF
16.8 SF

1/2" AROUND ALL SIDES

2"

41.4 SF
51.8 SF
6.3 SF
35.2 SF
110
80

17.0 SF
10.5 SF
9.9 SF
7.3 SF
6.2 SF

GALVANIZED SHEET METAL CAP.


1" LARGER THAN CURB.

2"

41.4 SF
50.3 SF
6.3 SF
35.2 SF
17.6 SF
110
80

ROOFING
MATERIAL

REMARKS

CAULK TOP OF CURB

Level

ALL CURBS MADE OUT OF 2X12 WOOD


CANTOUR BY ROOFING CONTRACTOR.

1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR
1st FLOOR

2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR
2nd FLOOR

3rd FLOOR
3rd FLOOR

4th FLOOR
4th FLOOR

EXHAUST HOOD
NO TO SCALE

CONDENSER.

H.P.

ROOM NAME

09.29.16

ALL CURBS MADE OUT OF 2X12 WOOD


WITH 2X2 NAILER ON THREE SIDES

BIRD SCREEN

ACTUAL
EXH.

DATE:

BATHROOM
EXHAUSTS

ROOF HOOD SAME SIZE AS CURB CAP.

ACTUAL
LIGHT
VENT

1634

AC-1

ORIENT HOODS SUCH


THAT THEY ARE 15'-0"
FROM INLET OF FRESH
AIR

ORDINANCE REQ'D
LIGHT
VENT
EXH.

PROJECT #

METAL CAP.
ROOFING MATERIAL BY ROOFER.

BATT INSULATION

RUBBER
ISOLATION
GROMMET

METAL CURB ON ROOF

FOR BIDDING ONLY, NOT FOR CONSTRUCTION

ACTUAL CFM

GFI

REQ'D CFM

GFI

HEAT LOSS

515 SUMMIT AVE.


PARK RIDGE, IL 60068

LIVING / DINING
MASTER BEDROOM
KITCHEN
BEDROOM 2
BEDROOM 3
MASTER BATHROOM
BATH 2
LAUNDRY / MUDROOM
WIC
HALL
MECH CLOSET
BALCONY
VESTIBULE
STORAGE
STAIRS #1
STAIRS #2

AREA

GFI

1st FLOOR
LIVING/ DINING
MASTER BEDROOM
KITCHEN
BEDROOM 2
MASTER BATHROOM
BATH 2
LAUNDRY / MUDROOM
WIC
HALL
MECH CLOSET
LOBBY
TERRACE
STAIRS #1
STAIRS #2
2nd FLOOR - 3rd and 4th Similar

NO

GFI

ROOM NAME

CONDENSER ON
CURB DETAIL
NOT TO SCALE

D
2003 INTERNATIONAL MECHANICAL CODE SECTION 504.2:
PROHIBITS THE INSTALLATION OF A FIRE OR SMOKE
DAMPER IN THE DRYER EXHAUST DUCT SINCE HEAT OR
LINT COULD DAMAGE OR OBSTRUCT THE OPERATION OF
THE FIRE DAMPER. THEREFORE DUCTS CAN NOT
PENETRATE A FIRE-RESISTANCE RATED ASSEMBLY.

PROVIDE A MINIMUM 12
FT. CLEARANCE FROM
VENT HOOD DISCHARGE
TO ANY OUTSIDE AIR
INTAKE OPENING.

REMOVABLE HOOD
DESIGNED FOR ACCESS TO
DRYER CLEAN OUT
SEPERATE DRYER DUCTS TO
THE EXTERIOR.

ROOF
MAYTAG AUTOMATIC DRYER
INSULATION GUIDE
NUMBER
OF 90 DEGREE
TURNS

M1-1.2

ROOF MECHANICAL PLAN


SCALE: 1/4" = 1'-0"

ALL 26 GAUGE
5th FLOOR
4"

2- 1/2"
DRYER RISER 4" TYPICAL

MAXIMUM LENGHT OF 4" DIAMETER


RIGID METAL DUCT
0
65 FT
59 FT
1
54 FT
48 FT
2
44 FT
38 FT
3
36 FT
30 FT
4
28 FT
22 FT

36 FT
32 FT
28 FT
25 FT
23 FT

ORIENT HOODS SUCH THAT


THEY ARE 15'-0" FROM INLET
OF FRESH AIR

ORIENT HOODS SUCH THAT


THEY ARE 15'-0" FROM INLET
OF FRESH AIR

KITCHEN RISER 6"

BATH RISER 4"

3rd FLOOR

10.26.16

2nd FLOOR

MAXIMUM LENGHT OF 4" DIAMETER


FLEXIBLE STIFFED METAL DUCT
0
1
2
3
4

28 FT
24 FT
20 FT
17 FT
15 FT

ROOF HOOD SAME


SIZE AS CURB CAP.

DRAWN BY:
3rd FLOOR

3rd FLOOR

2nd FLOOR

2"

DRYER VENT RISER DETAIL


NOT TO SCALE

26 GAUGE & 90 DEGREE


SLEEVE THROUGH WALL

GALVANIZED SHEET
METAL CAP 1" LARGER
THAN CURB.
1/2" AROUND CLEARANCE
AROUND ALL SIDES
2" LIP TURNED DOWN

KITCHEN VENT DETAIL


NO TO SCALE

NOTE:
ALL FIRE DAMPERS TO COMPLY WITH THE
SPECIFIED U.L. DISIGN RATING AND 1993
BOCA NATIONAL BUILDING CODE.ALL ROUND
FIRE DAMPERS TO BE SPRING LOADED.

FZM

APPROVED BY: G.C.N.

BIRD SCREEN OVER OPENINGS

1. DUCTS EXCEEDING MANUFACTURERS RECOMMENDED LENGTH


A BOOSTER FAN KIT SHALL BE REQUIRED.
2. BOOSTER FAN KIT SHALL BE PROVIDED BY OWNER.
3. DUCTS ARE CONTINUOUS FROM DRYER CONNECTION IN UNIT TO THE
EXTERIOR.
4. DUCTS DO NOT EXCEED 4" IN DIAMETER
5. TOTAL AREA OF DUCTS LESS THAN 100 SQUARE INCHES FOR ANY 100 SQ.
FEET.
OF FLOOR AREA. A 4" RD DUCTS IS 12.5 SQ. INCHES, THEREFORE 8 DUCTS
MAXIMUM.
6. DUCTS ARE LOCATED WITHIN THE CAVITY.
7. MINIMUM DUCT THICKNESS IS 0.019 INCHES.
8. THE ANNULAR SPACE AROUND DUCTS IS PROTECTED WITH MATERIALS THAT
PREVENT
THE PASSAGE OF FLAME AND HOT GASES SUFFICIENT TO IGNITE COTTON
WASTE.

ISSUED FOR PERMIT

2nd FLOOR

26 GAUGE & 90 DEGREE


SLEEVE THROUGH WALL

BATH VENT DETAIL


NO TO SCALE

NOTE:
ALL FIRE DAMPERS TO COMPLY WITH THE
SPECIFIED U.L. DISIGN RATING AND 1993 BOCA
NATIONAL BUILDING CODE.ALL ROUND FIRE
DAMPERS TO BE SPRING LOADED.

SCALE:

AS NOTED

DESCRIPTION:

ROOF MECH. PLAN


SCHEDULES,
NOTES & DTLS

SHEET NO.

M1-1.2

ELECTRICAL NOTES
1) ELECTRICAL SERVICE & PANEL to be 400 AMP.

36) ALL SMOKE AND CO MUST BE AT LEAST 3 FT AWAY FROM


VENTS.
37) USE PHASE COLOR WIRING. NO TAPE.

2) NO SUB PANELS IN BASEMENT.

STORAGE

LAUNDRY /
MUDROOM

118

107

TV

100 AMP ELEC


PANEL
FD

SD

ELECTRICAL SYMBOL
SMOKE DETECTOR

CO

CARBON MONOXIDE DETECTOR


DUPLEX RECEPTACLE

42
GFI

GROUND FAULT RECEPTACLE

WP

WEATHERPROOF EXTERIOR
RECEPTACLE

3
100 AMP
COMMON
HOUSE
PANEL

FD

XX

SD

600 AMP
MAIN
PANEL

ELECTRICAL RM

116

18) ALL BRANCH CIRCUITS THAT SUPPLY 125 VOLTS, SINGLE


PHASE, 15 AND 20 AMPERE OUTLETS INSTALLED IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC-FAULT
CIRCUIT INTERRUPTER LISTED TO PROVIDE PROTECTION OF THE
ENTIRE BRANCH CIRCUIT.

CO

GFI
42

HALL

MECH CLOSET

109

110

GFI
42

MASTER
BATHROOM

EF

09.29.16

117

GFI
42

DATE:

SPRINKLER RM

GFI
42

GFI
42

REF.
RECEPTACLE (DED. CIRCUIT)
REF - REFRIGERATOR
FURN - FURNACE
WH WATER HEATER
EJEC - EJECTOR PUMP
SUMP - SUMP PUMP
OV OVEN (220V)
HD KITCHEN HOOD
CK COOKTOP

108

1634

105

FD
R

WH
KITCHEN

VP
GFI

103

RECEPTACLE
xx INCHES A.F.F.

BATH 2

RECEPTACLE - CEILING

EM

THERMOSTAT

SD

21) SERVICE TO BE UNDERGOUND

RECESSED DOWNLIGHT
R - 5" DIA
RW - CLOSED LENS, WET LOC.

3
3

FLOURESCENT
CEILING FIXTURE

23) SURFACE MOUNTED CLOSET LIGHTS SHALL NOT BE LOCATED


WITHIN 30" FROM ANY WALLS. SURFACE MOUNTED FLORESCENT
IS PERMITTED ON THE INSIDE WALL ABOVE THE CLOSET OPENING.

GFI

PH
DATA

TRACK LIGHTING

24) SMOKE/CO MUST BE HARDWIRED WITH BATTERY BACK-UP AND


INTERCONNECTED. RUN ON ITS OWN CONDUIT SEPARATE FROM
ANY CIRCUITS AND ON ITS OWN CIRCUIT BREAKER WITH A
BREAKER LOCK.

FD

DECOR.
PENDANT FIXTURE

LIVING/ DINING

TO FIXTURE
ABOVE

101

STORAGE

113

DECOR.
SURFACE MOUNTED W/ PULL
CHAIN

PC

25) METER SOCKET MUST HAVE DISCONNECT AND BE CECHA


APPROVED.
J

26) ARC FAULTS REQUIRED ON EVERYTHING EXCEPT: GARAGE,


BATHROOMS, ATTIC, CRAWL, OUTDOORS, SMOKE, CO
DETECTORS,FIRE, FRIDGE, SUMP PUMPS AND DEDICATED
CIRCUITS.

TO COMMON
HOUSE PANEL

SWITCH
3 - THREE-WAY
D - DIMMER

FAN

DECOR. LIGHT FIXTURE


CL - CEILING
CH - CHANDELIER / FAN

SD

SD

CO

DECOR. WALL SCONCE


LOW VOLTAGE
TV - CO-AXIAL

TV

LOW VOLTAGE
INTERNET TERMINAL (CAT 5)

DATA

515 SUMMIT AVE.


PARK RIDGE, IL 60068

19) ALL CEILING BOXES TO BE FAN RATED.

EF

106

DUPLEX RECEPTACLE - FLOOR

MULTY FAMILY BUILDING

XX

FOR BIDDING ONLY, NOT FOR CONSTRUCTION

SD

WIC

PROJECT #

GFI

DESCRIPTION

TO COMMON
HOUSE PANEL

MARK

17) ALL LOW VOLTAGE WIRING FOR THE DOORBELLS AND HVAC
MUST BE IN CONDUIT.

27) ALL ARC FAULT CIRCUIT BREAKERS TO BE UL CERTIFIED AND


THE ARC FAULT CIRCUIT BREAKERS MUST BE COMBINATIONAL
TYPE ARC FAULT BREAKER.

44) DEDICATED ELECTRICAL SPACE REQUIRED INDOORS AND


OUTDOORS. PROVIDED SPACES TO BE 30"(W) X 26"(D) X 72"(H).

16) ALL SMOKE DETECTORS SHALL BE LINE VOLTAGE AND WIRED


TOGETHER.

22) EVERY DWELLING UNIT SHALL BE EQUIPPED WITH AT LEAST


ONE APPROVED 110V WITH BATTERY BACKUP CARBON MONOXIDE
ALARM IN AN OPERATING CONDITION WITHIN 15 FEET OF EVERY
ROOM USED FOR SLEEPING PURPOSES.

43) ALL SMOKE/CO DETECTORS MUST BE HARDWIRED


TOGETHER AND ON RACEWAY TO PANEL WITH BREAKER LOCK.

15) ALL OUTSIDE LIGHTS SHALL BE U.L. APPROVED FOR WET OR


DAMP LOCATIONS AS REQUIRED BY SECTION 410-4.

20) ELECTRICIAN MUST BE ON SITE FOR ALL INSPECTIONS

102

14) ALL RECEPTACLES SHALL BE GROUNDED AS REQUIRED BY


ARTICLE 250-146.

FAN

DATA

13) ALL EQUIPMENT SHALL BE U.L. APPROVED OR ANY OTHER


NATIONALLY RECOGNIZED TESTING COMPANY.

42) ALL BEDROOMS MUST HAVE SMOKE DETECTORS


HARDWIRED WITH BATTERY BACKUP.

12) ALL RECESSED CANS MUST BE IC RATED

MASTER
BEDROOM

GFI

11) CONDUIT BETWEEN HOUSE AND GARAGE MUST BE RIGID


GALVANIZED STEEL, 18" BELOW GROUND. CALL FOR INSPECTION
PRIOR TO COVERING.

115

10) PROVIDE SPEAKERS & WIRING FOR THE FAMILY ROOM &
DINING ROOM.

STAIRS #2

GFI

9) ELECTRICAL SERVICE GROUND MUST BE INSTALLED ON THE


STREET SIDE OF THE WATER METER, AND JUMPERED ACROSS
METER.

PH

EM

DW

8) ALL RECESSED CAN LIGHTS ARE 4" DIAMETER UNLESS


OTHERWISE NOTED

41) EXTERIOR GFCI RECEPTACLES SHALL BE WR AND HAVE


HEAVY DUTY COVERS PER NEC 2014.

GFI

7) A SWITCHED GFI OUTLET MUST BE INSTALLED AT THE FRONT


AND REAR ENTRIES.

TO FIXTURE
ABOVE

40) LAUNDRY AREAS NOW REQUIRED TO HAVE GFCI


PROTECTION FOR 125-VOLT, SINGLE PHASE, 15- AND 20AMPERE RECEPTACLES.

GFI
42

6) ATTIC FANS MUST BE INSTALLED WITH A HIGH TEMP. LIMIT


SWITCH.

39) HOT TUBS: RUN GREEN GROUND FROM PANEL TO HOT TUB
OUTLET. MUST HAVE DISCONNECT AND BE
GFCI
PROTECTED AND BE READILY ACCESSIBLE. USE GFCI
BREAKER OR FACELESS GFCI OUTSIDE HOT TUB.

GFI
42

5) ALL WHIRLPOOL TUBS SHALL BE GROUNDED FROM THE MOTOR


LUG TO THE NEAREST JUNCTION BOX.

TO COMMON
HOUSE PANEL

GFI
42

4) ALL ELECTRICAL DEVICES AND CONTROLS SHALL BE LOCATED


NO LESS THAN 5'-0" FROM ANY TUB OR SHOWER.

38) ARC FAULTS ON EVERYTHING EXCEPT: GARAGE,


BATHROOMS, ATTIC, CRAWL, OUTDOORS, SMOKE, CO
DETECTORS, AND DEDICATED CIRCUITS. NO ARC FAULT
CIRCUIT BREAKERS OR GFCI'S ON : SMOKE/CO DETECTORS,
FIRE, FRIDGE, AND SUMP PUMPS.

TV

3) SMOKE DETECTORS SHALL BE WIRED ON A SEPARATE CIRCUIT,


AND IN SERIES; ONE SOUNDS, ALL SOUND.

3
J
3

FAN

28) ALL ALTERED OR NEW OUTLETS TO BE "TAMPERED RESISTANT


OUTLETS".
29) WET LOCATIONS NEED HEAVY DUTY COVERS AND WET
RESISTANT RECEPTACLES.

GFI

LOW VOLTAGE
TELEPHONE OUTLET

PH

EF

BEDROOM 2

104

EXHAUST FAN

ELECTRICAL PANEL

30) 75% OF ALL NEW LIGHTING SHALL BE ENERGY EFFICIENT PER


IECC 2012.
EM

ELECTRICAL METER

31) LIGHTS ABOVE TUBS AND SHOWERS TO BE WATER/VAPER


PROOF.
32) ANY NEW ELECTRICAL METER SOCKETS MUST HAVE
EXTERNAL DISCONNECT AND BE CECHA APPROVED.
33) ALL ALTERED OR NEW OUTLETS TO BE "TAMPERED RESISTANT
OUTLETS".

2
E1-1.1

1st FLOOR ELECTRICAL PLAN


SCALE: 1/4" = 1'-0"

10.26.16

ISSUED FOR PERMIT

34) ANY NEW CIRCUIT BREAKER PANELS OR PANELS THAT WILL BE


MOUNTED TO CONCRETE MUST HAVE PLYWOOD BETWEEN PANEL
AND CONCRETE.

DRAWN BY:

SCALE:

AS NOTED

35) ALL BOXES ON CEILING MUST BE FAN RATED.

DESCRIPTION:

FIRST FLOOR ELEC


PLAN

FZM

APPROVED BY: G.C.N.

SHEET NO.

E1-1.1

ELECTRICAL SYMBOL
MARK

BALCONY

RECESSED INCANDESCENT
OR FLOURESCENT

DESCRIPTION
SURFACE INCANDESCENT

SD

SMOKE DETECTOR

CO

CARBON MONOXIDE DETECTOR

SURFACE INCANDESCENT
OR FLOURESCENT

SURFACE FLOURESCENT ONLY

WP

5"

DUPLEX RECEPTACLE

WEATHERPROOF EXTERIOR
RECEPTACLE

FROM
FIXTURE
BELOW

STORAGE
AREA

TV

202

STAIRS #2

DATA
J

216

FAN

LAUNDRY /
MUDROOM

D
RECEPTACLE
xx INCHES A.F.F.

SURFACE MOUNTED OR RECESSED


FIXTURE ACCEPTABLE

BEDROOM 3

208

205

DUPLEX RECEPTACLE - FLOOR

XX

MASTER
BEDROOM

EM

RECEPTACLE (DED. CIRCUIT)


REF - REFRIGERATOR
FURN - FURNACE
WH WATER HEATER
EJEC - EJECTOR PUMP
SUMP - SUMP PUMP
OV OVEN (220V)
HD KITCHEN HOOD
CK COOKTOP

XX

PH

100 AMP ELEC


PANEL

FD

RECEPTACLE - CEILING

SD

THERMOSTAT

FAN

GFI
42

210

GFI
42

GFI
42

REF.

MASTER
BATHROOM

206
R

GFI
42

FD

SERVICE

203
GFI

3 X 500 MCM

GFI

DECOR. LIGHT FIXTURE


CL - CEILING
CH - CHANDELIER / FAN

KITCHEN

PP-1
TYPICAL UNIT
PANEL

LOW VOLTAGE
TV - CO-AXIAL

100 A
PROTECTION

BATH 2

EM

1 PHASE
42 CIRCUITS

LOW VOLTAGE
TELEPHONE OUTLET

SD VESTIBULE
213

TO COMMON
HOUSE PANEL

EXHAUST FAN
1" - 3 x #3 TWHN
EACH UNIT
ELECTRICAL PANEL
ELECTRICAL METER

LIVING / DINING

COMMON HOUSE
PANEL

201
PH
DATA

STAIRS #1

TV

1 PHASE

215

42 CIRCUITS

PP-M
2nd SUPPLEMENTAL
GROUND 1/2" EMT #6 CU
TWHN ATTACHED TO 2 x
5/8" GROUND ROD (6 FT
AWAY FROM 1st)

1st SUPPLEMENTAL
GROUND 1/2" EMT #6 CU
TWHN ATTACHED TO 2 x
5/8" GROUND ROD

600 A
TO WATER METER 1"
EMT #2/0 CU TWHN
ATTACHED TO 5/8"
GROUND ROD

STORAGE

TO FIXTURE
ABOVE

MAIN BREAKER PANEL

1 x 100A
COMMON
HOUSE METER

SD

CO

SD

PROTECTION
1 PHASE

214

42 CIRCUITS

m
3
J
FAN
3

EM

PP-2

100 A
PROTECTION

2 x 3" RIGID
500 MCM

EF

207
GFI
42

DECOR. WALL SCONCE

LOW VOLTAGE
INTERNET TERMINAL (CAT 5)

EF

VP
GFI

GFI
42

WH

GFI
42 DW

BATH LIGHTING LOCATIONS

PH

GFI
42

GFI
42

3'-0"

DECOR.
SURFACE MOUNTED W/ PULL
CHAIN

DATA

CO

EF

DECOR.
PENDANT FIXTURE

TV

09.29.16

HALL

SD

BATHTUB

FAN

DATE:

SD

TRACK LIGHTING

1634

4
R

HANGING, CORD
CONNECTED, OR
PENDANT
FIXTURE IN THIS AREA

FLOURESCENT
CEILING FIXTURE

PC

PROJECT #

4
NO HANGING, CORD
CONNECTED, OR PENDANT
FIXTURE IN THIS AREA

RECESSED DOWNLIGHT
R - 5" DIA
RW - CLOSED LENS, WET LOC.

209

SWITCH
3 - THREE-WAY
D - DIMMER
R

WIC

FOR BIDDING ONLY, NOT FOR CONSTRUCTION

WP

TO FIXTURE
ABOVE

8": FLOURESECENT
12" INCANDESCENT

515 SUMMIT AVE.


PARK RIDGE, IL 60068

GROUND FAULT RECEPTACLE

STORAGE
AREA

MULTY FAMILY BUILDING

42
GFI

12"

1" EMT #2/0 CU TWHN


ATTACHED TO 5/8"
GROUND ROD

GFI

4 x 100A
RESIDENTIAL
METERS

BEDROOM 2

204

CONCRETE ENCASED
ELECTRODE

ELECTRICAL LINE DIAGRAM

1
E1-1.2

TYPICAL FLOOR ELECTRICAL PLAN


SCALE: 1/4" = 1'-0"

10.26.16
DRAWN BY:

ISSUED FOR PERMIT


FZM

APPROVED BY: G.C.N.


SCALE:

AS NOTED

DESCRIPTION:

TYPICAL FLOOR
ELECTRICAL PLAN

SHEET NO.

E1-1.2

A.1

A.1

STAIRS #2

MASTER
BEDROOM

216

202

STAIRS #2

115

B
D

MASTER
BEDROOM

102

STORAGE

2" V

2" W

P3, W3

118

LAUNDRY /
MUDROOM

208

FD

LAUNDRY /
MUDROOM

2" V

2" W

P3, W3

107

FD

2" W

2" W

2" W

2" W

WIC

PROJECT #

1634

DATE:

09.29.16

WIC

108

209
BEDROOM 3
FD

ELECTRICAL RM

210

2" W

SPRINKLER RM

2" W
4" V
4" W

211

2" W

117

4" V
4" W

MASTER
BATHROOM
MECH CLOSET

206

2" V

REF.

WH
203

2" W

P1,W1

2" W

2" V
2" W

2" V
2" W

WH
KITCHEN

DW

DW

KITCHEN

2" W

103

6" W

2" W

2" W

C.O.
BATH 2

4" V
4" W

207

2" W
2" V

P1,W1

4" W

C.O.

2" W

2" W

105

4" W
FD

2" V

2" V

MASTER
BATHROOM

110

REF.

2" W

FD

P2, W2

109

116

MECH CLOSET

HALL

2" V

P2, W2

HALL

4" V
4" W

2" W
2" V

2" V
2" W

BATH 2

2" W

P4, W4

106

P4, W4

2" W

LOBBY

213

111

LIVING / DINING

201

C.O.

LIVING/ DINING

101

2" V
2" W
FD

STORAGE

214
STORAGE

113
STAIRS #1
STAIRS #1

215

114

515 SUMMIT AVE.


PARK RIDGE, IL 60068

VESTIBULE

MULTY FAMILY BUILDING

C.O.

FOR BIDDING ONLY, NOT FOR CONSTRUCTION

205

6" PVC TO SANITARY


SEE CIVIL DRAWINGS

BEDROOM 2

204

BEDROOM 2

D
2
P1-1.1

TYPICAL FLOOR PLUMBING PLAN


SCALE: 1/4" = 1'-0"

104

1
P1-1.1

1st FLOOR PLUMBING PLAN


SCALE: 1/4" = 1'-0"

10.26.16
DRAWN BY:

ISSUED FOR PERMIT


FZM

APPROVED BY: G.C.N.


SCALE:

AS NOTED

DESCRIPTION:

FIRST AND TYP FLR


PLUMBING PLNS

SHEET NO.

P1-1.1

GENERAL PLUMBING NOTES:


ALL WORK PERFORMED BY PLUMBING CONTRACTOR SHALL COMPLY WITH ALL CITY OF
PARK RIDGE, STATE OF ILLINOIS, AND ALL OTHER CODES THAT APPLY TO THIS
PROJECT.

P1
4x5 UP
THRU
ROOF

ROOF

THE PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE AND FULLY
OPERATING SYSTEM FOR THE SOIL, WASTE, VENT, SEWER, DOMESTIC COLD WATER
AND NATURAL GAS SERVICES. THE CONTRACTOR SHALL EXTEND THESE
SERVICES
TO ALL OTHER FIXTURES SHOWN ON THE DRAWINGS AND PROVIDE ALL CONNECTORS,
UNIONS AND TRAPS REQUIRED FOR FINAL CONNECTION TO ALL EQUIPMENT, WHETHER
FURNISHED IN THE PLUMBING WORK OR SUPPLIED BY OTHER TRADES.

4"W

BATH 2

MSTR BATH

2"W

2"W

2"W

MSTR BATH

4"W

BATH 2

WC

MECH

2"W

2"W

2"W

2"W

2"W

MSTR BATH

16)

GREY
BOX

SINK
2"W

GREY
BOX
2"W

2"W

LAUNDRY
2"V

2"V

4"W

BATH 2

MSTR BATH

MECH

2"W

2"W

WASTE LINES TO ALL WATER CLOSETS MUST BE 4" MIN. DIAMETER.

2"W

2"W

2"W

MSTR BATH

4"V

2"W

2"W

PROJECT #

1634

DATE:

09.29.16

2"W

2"W

LAUNDRY

4"V

2"V

GREY
BOX

2"V

2"V

SINK

2"V

GREY
BOX

2"V

2"V

LAV

LAV
WC

FD

2" W

4"V

2"V

SH

2ND FLOOR

2"V

TUB

4"V

2"V

SINK

1 1/2"V

2"V

2"V

2"V

4"V
4"W

ENTIRE INSTALLATION SHALL BE IN A FIRST-CLASS WORKMANLIKE MANNER. THE


COMPLETED SYSTEMS SHALL BE FULLY OPERATIONAL. ALL WORK SHALL BE
COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCES, AND PRESERVE
HEADROOM. ALL WORK MUST BE PLANNED AND PERFORMED IN SUCH A MANNER
AS
NOT TO INTERFERE WITH COMPLETION OF ANY OTHER WORK ON THE PREMISES.

BATH 2

4"W

MSTR BATH

WC

FD

MECH

SPRINKLER RM

2"W

2"W

2"W

MSTR BATH

2"W

2"W

STORAGE

2"W

LAUNDRY

4"V

2"W

2"V

GREY
BOX

2"V

2"V

SINK

2"V

GREY
BOX

2"V

1 1/2"V

2"V

FD

LAV

2"V
4"V

FD

2" W

1 1/2"V

2"V

SH

1ST FLOOR

2"V

TUB/SH

4"V

ALL FOOTING DRAIN TILE SHALL BE 6" PVC SUBSURFACE DRAIN PIPE SCHEDULE 40
W/ NYLON SOCK FILTER FABRIC- ASTM D3034, SPR 35

2"V

LAV

2"V

1 1/2"V

TUB

ALL FLOOR DRAINS MUST BE ACID AND RUST RESISTANT, AND SHALL BE CAST IRON
OR BRONZE.

LAV

4"W

2"W

KITCHEN

2"W
GRASE TRAP

6" SANITARY

6" W PVC
SAN

INSTALL AIR CHAMBERS TO PREVENT NOISE AND DAMAGE TO WATER HAMMER.

VENT

SCALE: 1/4" = 1'-0"


AIR CHAMBER

19)

ALL CLEAN-OUTS SHALL TERMINATE FLUSH WITH THE FINISH FLOOR OR WALL.

20)

PROVIDE VACUUM BREAKERS TO PLUMBING FIXTURES AS REQUIRED BY APPLICABLE


CODES.

21)

SLOPE ALL SANITARY LINES 1/4" PER FOOT OR AS SHOWN ON THE DRAWINGS.

3/4"

3/4"

3/4"

LAV

WC
WH-1
50 GAL

SH

1/2"

WC
3/4"

1/2"

1/2"

23)

AREA DRAIN SHALL TIE INTO STORM SUMP (NO TRAP).

24)

SAFE PAN REQUIRED FOR WASHING MACHINE.

25)

A STACK TEST SHALL BE WITNESSED BY THE CITY OF PARK RIDGE INSPECTOR.

26)

WATER PIPE SIZING SHALL MAINTAIN SERVICE SIZE TO FIRST BRANCH OR WATER
HEATER LOCATION

VENT STACK SHALL BE LOCATED A MINIMUM OF 10' FROM ANY FRESH INTAKE OR
ATTIC VENTILATION OPENINGS

BATH 2

AIR CHAMBER

3/4"

WH-1
50 GAL

SH

LAV

1/2"

KITCHEN

LAUNDRY

3/4"

1/2"

SH

LAV

1/2"

3/4"

TUB

3/4"

K SINK

1/2"

GREY
BOX

DW

1/2"

1/2"

1/2"

BATH 2

AIR CHAMBER

3/4"

MSTR BATH

3/4"

KITCHEN

LAUNDRY

3/4"

WH-1
50 GAL

SH

LAV

1/2"

LAV

WC
3/4"

1/2"

SH

LAV

1/2"

3/4"

TUB

3/4"

K SINK

1/2"

GREY
BOX

DW

1/2"

1/2"

1/2"

2ND FLOOR
3/4" WATER METER

BATH 2

MSTR BATH

KITCHEN

LAUNDRY

24"

AIR CHAMBER

NEW 3/4" FROM


BUILDING MAIN

24"

LEAD FLASHING IS REQUIRED FOR VENT TERMINATION

LAV

WC

1/2"

32)

1/2"

3RD FLOOR

THE CONTRACTOR INSTALLING WATER SERVICE SHALL BE AN ILLINOIS STATE


LICENSED PLUMBER AND BE LICENSED AS A PLUMBING CONTRACTOR.
ALL HOT WATER PIPES SHALL BE INSULATED PER 2012 I.E.C.C.

1/2"

3/4"

WC

31)

1/2"

MSTR BATH

3/4"

WC

29) CONTACT PUBLIC SERVICES AT 72 HOURS PRIOR TO REQUESTING


A WATER MAIN
TAP.
30)

3/4"

GREY
BOX

DW

24"

28)

3/4"

K SINK

4TH FLOOR

24"

DRAIN TILE SHALL BE LOOPED , COVERED WITH FABRIQUE AND 12" STONE.

1/2"

TUB

1/2"

1/2"

27)

SH

LAV

24"

NATURAL GAS PIPING SHALL BE SCHEDULE 40 STANDARD WEIGHT MALLEABLE IRON.

24"

22)

LAV

515 SUMMIT AVE.


PARK RIDGE, IL 60068

P1-1.2

PLUMBING WASTE DIAGRAM

MULTY FAMILY BUILDING

INSTALL CLEAN-OUTS WITH PROPER ACCESS CLEARANCE, AS REQUIRED BY


APPLICABLE CODES.

24"

18)

PROVIDE AND INSTALL SHUT-OFF VALVES IN THE SUPPLY PIPING FOR EVERY
FIXTURE.

24"

17)

FOR BIDDING ONLY, NOT FOR CONSTRUCTION

15)

2"W

2"V

4"W
2"V

WC

14)

4"V

SINK

2"V

2"V

4"V

CO

13)

2"V

2"V

GREY
BOX

2"V

4"V

12)

2"W

2"W

LAUNDRY

4"V

4"W

TUB/SH

ALL BELOW GROUND WATER PIPING SHALL BE TYPE "K" COPPER PIPE. 3" WATER
LINES
AND LARGER SHALL BE DUCTILE IRON PIPE.

2"W

2"V

2"V

2"V

LAV

4"V

2"V

MSTR BATH

LAV

2"V

FD

TUB/SH

2" W

2"V

LAV

11)

2"W

SINK

1 1/2"V

2"V

LAV
WC

3RD FLOOR

WC

ALL ABOVE GROUND WATER PIPING SHALL BE TYPE "L" COPPER.

4"V

2"V

4"W

4"V

CLEAN, TEST AND BALANCE ALL SYSTEMS TO CONFORM WITH THE CITY OF PARK
RIDGE CODES. MAKE ALL REQUIRED ADJUSTMENTS.

10)

2"V
2"V

4"V

CLEANING UP IS REQUIRED AS JOB PROGRESSES. KEEP PREMISES AND PUBLIC WAYS


BROOM CLEAN.

ALL DRAINAGE PIPING BELOW GRADE INCLUDING WASTE, VENT AND STORM, SHALL
BE CAST IRON, WITH PROPER CONNECTORS.

GREY
BOX

2"W

4"V

4"W

PLUMBING CONTRACTOR SHALL FURNISH A WRITTEN GUARANTEE OF ALL


WORKMANSHIP AND MATERIALS FOR ONE YEAR FROM DATE OF SUBSTANTIAL
COMPLETION ACCEPTANCE.

9)

4"V

2"W

4"V

8)

2"V

SINK

LAV

LAV
WC

MECH

4"V

SINK

7)

4x5 UP
THRU
ROOF

2"V

2"V

4"V

SITE CONDITIONS ARE PART OF THIS CONTRACT. PLUMBING CONTRACTOR IS


RESPONSIBLE TO CHECK AND VERIFY DIMENSIONS, ELEVATIONS AND EXISTING
CONDITIONS AT THE SITE PRIOR TO PROCEEDING WITH HIS WORK.

2"V

6)

4"V

FD

2" W

2"V

4"V

2"V

SH

4TH FLOOR

2"V

SH

5)

4"V

TUB/SH

PLUMBING CONTRACTOR SHALL OBTAIN AND PAY ALL FEES AND TAXES FOR
NECESSARY PLUMBING PERMITS. ALL FEES AND TAXES SHALL BE INCLUDED IN THE BID
PROPOSAL.

1 1/2"V

2"V

LAV

4)

4x5 UP
THRU
ROOF

4"V

WC

PLUMBING CONTRACTOR MUST BE LICENSED AS REQUIRED BY THE VILLAGE OF


GLENVIEW AND THE STATE OF ILLINOIS.

P4

4"W
2"V

3)

P3

4x5 UP
THRU
ROOF

TUB

2)

P2

TUB

1)

3/4" WATER METER


NEW 3/4" FROM
BUILDING MAIN

3/4"

3/4"

3/4"

WC

3/4" WATER METER


NEW 3/4" FROM
BUILDING MAIN

WH-1
50 GAL

3/4" WATER METER


NEW 3/4" FROM
BUILDING MAIN

SH

LAV

1/2"

LAV

WC
3/4"

1/2"

1/2"

SH

LAV

1/2"

3/4"

TUB

3/4"

K SINK

1/2"

GREY
BOX

DW

1/2"

1/2"

1/2"

1ST FLOOR
BATH 2
CW
HW

2
P1-1.2

PLUMBING SUPPLY DIAGRAM

MSTR BATH

KITCHEN

LAUNDRY

10.26.16
DRAWN BY:

ISSUED FOR PERMIT


FZM

APPROVED BY: G.C.N.


SCALE:

AS NOTED

DESCRIPTION:

PLUMBING
DIAGRAMS AND
NOTES

SCALE: 1/4" = 1'-0"


SHEET NO.

P1-1.2

1 8 F T G R A V E L A L L E Y

Planting Schedule
LEGEND QUANT. BOTANICAL NAME
DECIDUOUS & ORNAMENTAL TREES

COMMON NAME

SIZE

NOTES/SPECIAL CONDITIONS

AL

Amelanchier Laevis

Serviceberry

8'ht

B&B, Clump

CC

Cercs Canadensis

Eastern Redbud

8'ht

B&B, Clump

SHRUBS
TM
18

Taxus x media 'Everlow'

Dark Yew

24" spr.

24" o.c.

SB

11

Spirea Bumalda

Bumald Spirea

30" spr.

B&B

SP

11

Spirea Japonica

Little Princess Spirea

30" spr.

B&B

SG

Panicum virgatum 'Heavy Metal'

Switch Grass

36" spr.

B&B

Salvia (Blue)

2" pot

CG

Periwinkle

2" pot

CG

PERENNIALS & GROUND COVER


Vergosa Nemorosa
8
VN
VM

18

Vinca minor

4 CAR
DETACHED
GARAGE

PRUNE DAMAGED & BROKEN BRANCHES AND


TWIGS AS INDICATED BY GROWTH HABIT DO
NOT CUT LEADERS & TERMINAL BUDS

GENERAL NOTES:
TREE WRAP (FOR FALL PLANTING ONLY)

1. CONTRACTOR SHALL NOTIFY LANDSCAPE ARCHITECT


/OWNER IMMEDIATELY OF ANY DISCREPANCIES,
OBSTACLES AND/OR PROBLEMS.

PROJECT #

1634

DATE:

09.29.16

REMOVE ALL WIRE AND 1/3 BURLAP WRAP

FROM TOP OF ROOT BALL

2. VERIFICATION OF DIMENSIONS AND GRADES, BOTH


EXISTING AND PROPOSED, SHALL BE THE CONTRACTOR'S
RESPONSIBILITY PRIOR TO COMMENCEMENT OF WORK.
THE CONTRACTOR SHALL NOTIFY THE OWNER OF ANY
DISCREPANCIES.

REMOVE ALL WIRE AND 1/3 BURLAP WRAP


FROM TOP OF BALL.

48" W.I. FENCE

48" W.I. FENCE

3" SHREDDED HARDWOOD BARK MULCH

WITHIN SAUCER

3" SHREDED HARDWOOD MULCH WITHIN SAUCER

CONSTRUCT A 3" SAUCER WITH SOIL,


4' IN DIAMETER
2" MIN
.

PLANTING MIXTURE AND


FERTILIZER (SEE GENERAL NOTES)

4. CONTRACTOR SHALL NOTIFY OWNER OF ANY


UNDESIRABLE DRAINAGE CONDITIONS AND RECOMMEND
SUITABLE SOLUTIONS. WHERE NECESSARY TO ACHIEVE
PROPER DRAINAGE, UNDER DRAINAGE FOR TREE PITS
SHALL BE INSTALLED AT THE DIRECTION OF THE
LANDSCAPE ARCHITECT.

2'
min.

LANDSCAPE
AREA
PLANTING MIXTURE
(SEE GENERAL NOTES)

6" MOUND OF COMPACTED EXISTING SOIL


EXISTING SUBGRADE

UP

6" MOUND OF COMPACTED EXISTING SOIL

EXISTING SUBGRADE

5. LANDSCAPE CONTRACTOR SHALL REPAIR IN KIND ALL


AREAS DAMAGED AS A RESULT OF LANDSCAPE
OPERATIONS.

PRUNE DAMAGED & BROKEN BRANCHES


AND TWIGS AS INDICATED BY GROWTH HABIT
DO NOT CUT LEADERS & TERMINAL BUDS.

SET BALL AT LEVEL SO THAT TOP OF BALL


IS AT FINISHED GRADE AFTER SETTLEMENT.

7. ALL GROUND COVER/PERENNIAL BEDS TO RECEIVE A


MINIMUM 2" OF MUSHROOM COMPOST.

NOMINAL PLANTING SOIL ON TOP


OF BALL.
REMOVE ALL WIRE AND 1/3 BURLAP WRAP
FROM TOP OF BALL.

8. SIZES SHOWN ON PLANTING PLAN ARE MINIMUM


ACCEPTABLE SIZES.

MIN. 3" SHREDDED HARDWOOD


MULCH WITHIN SAUCER.
CONSTRUCT A 3" SAUCER WITH SOIL,
4' IN DIAMETER.

12" MIN.

9. LANDSCAPE CONTRACTOR SHALL WARRANT ALL TREES,


SHRUBS, VINES, GROUNDCOVERS AND PERENNIALS UNDER
THIS CONTRACT WILL BE HEALTHY AND IN FLOURISHING
CONDITION OF ACTIVE GROWTH ONE YEAR FROM DATE OF
FINAL ACCEPTANCE.

UP

FINISHED GRADE

PLANTING SOIL MIXTURE


(SEE GENERAL NOTES)
6" MOUND OF EXISTING SOIL
EXISTING SUBGRADE

10. SOIL TO BE USED FOR THE PLANTING MEDIUM FOR THE


PROJECT SHALL BE FERTILE, WELL DRAINED, OF UNIFORM
QUALITY, FREE OF STONES OVER 1" IN DIAMETER, STICKS,
OILS, CHEMICALS, PLASTER, CONCRETE AND OTHER
DELETERIOUS MATERIALS.

VARIES

FINISHED GRADE

TYPICAL
TRIANGULATED SPACING

PRUNE AT THE
DIRECTION OF THE
LANDSCAPE ARCHITECT

6" MIN.

PLAN

3" HARDWOOD BARK


MULCH WITHIN SAUCER

EQUAL

CONSTRUCT 3" SAUCER


WITH SOIL

EQUAL

FINISHED GRADE

PLANTING MIXTURE
(SEE GENERAL NOTES)

PLANTING MIXTURE AND


FERTILIZER (SEE GENERAL NOTES)

12" MIN

REMOVE ALL WIRE AND


1/3 OF BURLAP WRAP
ON BALLED AN BURLAPPED
SHRUBS

3 AL
8 VN

EXISTING SUBGRADE

EXISTING SUBGRADE
EXISTING SOIL
LEVELING COURSE

SPACING VARIES REFER


TO PLAN OR PLANT SCHEDULE
FOR SPACING

18 TM
2 SG

3" MUSHROOM COMPOST


FULLY DECOMPOSED AND COMPOSTED

6"

6"

18" MIN.

11. THE LANDSCAPE CONTRACTOR SHALL PREPARE


PLANTING BEDS BY ADDING SOIL AMENDMENTS TO
TOPSOIL MIX IN THE FOLLOWING QUANTITIES: TOPSOIL
MIX FOR TREES AND SHRUBS SHALL BE THREE ( 3 ) PARTS
TOPSOIL, ONE ( 1 ) PART PEAT, AND ONE ( 1 ) PART SAND.
TOPSOIL MIX FOR PERENNIALS, BULBS, AND GROUND
COVERS SHALL BE THREE ( 3 ) PARTS TOPSOIL, ONE ( 1 )
PART SAND AND TWO ( 2 ) PARTS DECOMPOSED
MUSHROOM COMPOST. SOIL SHALL MEET THE FOLLWING
REQUIREMENTS: SOIL COMPOSITION-45-77% SILT, 0-25%
CLAY, 25-33% SAND; SOIL ACIDITY: Ph 6.0-7.0; SOIL ORGANIC
CONTENT: THREE (3) TO FIVE (5) PERCENT.

EQ
UA
L

SEE PLAN/PLANT SCHEDULE

2 SG
1 CC
11 SB
11 SP
18 VM

SECTION

2 SG

515 SUMMIT AVE.


PARK RIDGE, IL 60068

4 STORY BRICK
AND BLOCK AND
FRAME
RESIDENTIAL
BUILDING

MULTY FAMILY BUILDING

SET TREE PLUMB IN CENTER OF PIT.

6. ALL TREE AND SHRUB BEDS TO RECEIVE A MINIMUM 3"


OF SHREDDED HARDWOOD MULCH.

FOR BIDDING ONLY, NOT FOR CONSTRUCTION

3. ALL SURFACE DRAINAGE SHALL BE DIRECTED AWAY


FROM STRUCTURES. SURFACE DRAINAGE SHALL BE
DIRECTED TO EXISTING CATCH BASINS DESIGNATED FOR
THE COLLECTION OF SURFACE RUN-OFF.

CONSTRUCT A 3" SAUCER WITH SOIL.


4' IN DIAMETER

1 AL
1 CC

SODDED AREA

12. ALL PLANTS TO BE BALLED IN BURLAP OR CONTAINER


GROWN AS SPECIFIED ON PLANTING PLAN. ALL PLASTIC
ROOT WRAPPING MATERIAL AND METAL WIRE BASKETS
SHALL BE REMOVED.
13. LANDSCAPE CONTRACTOR SHALL STAKE THE
LOCATION OF ALL TREES AND PLANTING BED LINES AND
HAVE LAYOUT APPROVED BY LANDSCAPE
ARCHITECT/OWNER PRIOR TO PLANTING.
14. WATER ALL PLANTS IMMEDIATELY AFTER PLANTING.
FLOOD PLANTS TWICE DURING FIRST TWENTY-FOUR HOUR
PERIOD AFTER PLANTING.
15. ALL NEW AND TRANSPLANTED PLANTS TO BE SPRAYED
WITH AN ANTIDESSICANT WITHIN TWENTY FOUR HOURS
AFTER PLANTING. ANTI-TRANSPIRANT SHALL BE EQUAL
TO "WILTPRUF."
16. ALL MUD SHALL BE REMOVED FROM ALL TIRES BEFORE
LEAVING THE SITE AND ROADS SHALL BE KEPT CLEAR OF
MUD AND DEBRIS AT ALL TIMES
.

S U M M I T A V E .
1
L-1

10.26.16
DRAWN BY:

ISSUED FOR PERMIT


FZM

APPROVED BY: G.C.N.

LANDSCAPE PLAN

SCALE:

AS NOTED

SCALE: 3/32" = 1'-0"

DESCRIPTION:

LANSCAPE PLAN
NOTES & DETAILS

SHEET NO.

L-1