Solutions to Membrane Fouling


By: Gil K. Dhawan Ph.D. P.E., Applied Membranes, Inc.
Note: Click Italicized Underlined words for product information.

Introduction to Membrane Fouling


All membranes lose their performance with time. One of the major causes for the loss of performance
with time. One of the major causes for the loss of performance is due to substances that deposit on
the membrane surface. Although the term fouling is used for deposit of any materials on the
membrane, the coating of the membrane surface can be due to the following:
Fouling
Scaling

Fouling
Fouling of membranes is due to the suspended or emulsified materials that may be present in the
feed water to the reverse osmosis system. Examples of such materials are: silica, oil, clay, iron,
sulfur and humic acids. These substances can be present in a very fine or colloidal form. Even the
typical 5 micron cartridge filters used upstream from a reverse osmosis system may not completely
remove these foulants.

Membrane Fouling and Scaling


The concentration of all materials in the feed water - dissolved and suspended - is highest near the
membrane surface. As permeate is removed through the membrane, all impurities are left behind
near the membrane surface. The layer of water next to the membrane surface (boundary layer) gets
more and more concentrated in the dissolved and suspended materials. These concentrations reach
a certain steady level depending on feed velocity, element recovery and membrane permeate flux
(gallons per square foot of permeate produced per day).
It is important to follow membrane manufacturers' recommendations on minimum feed flow, maximum
element recovery and maximum element flux. These recommendations are based on the element
size and quality of feed water being treated. The concentrations of the dissolved and suspended
solids in the boundary layer control the performance of the membrane. Higher concentrations mean
higher osmotic pressure, higher tendency of suspended solids to coagulate and coat the membrane
surface, and higher likelihood of scaling to take place. Maintaining proper operating conditions for the
membrane is the key preventative step to minimize membrane fouling.

11/25/2016 3:13 PM

Fouling Solutions

2 of 3

http://www.watertreatmentguide.com/membrane_fouling_solutions.htm

Antiscalant Injection
For non-residential systems, another option to avoid calcium carbonate and calcium sulfate scaling is
by the use of antiscalants. These are injected directly into the feed water upstream from the cartridge
filter. Dosage of antiscalant depends on the feed water analysis but usually is between 2 to 5 ppm.
In simplified terms, the antiscalants delay the scale formation process. This delay is sufficient to
avoid precipitation of calcium carbonate and calcium sulfate on the membrane surface. As this delay
is for a finite period, scaling can take place in systems on shut down. For this reason, it is a good
practice to flush the membranes with permeate or feed water at shut down. By this flush, the
concentrated solution in the membrane is displaced by the permeate or feed water.

Dispersant Injection
For suspended or colloidal materials, a dispersant can be injected in the feed water. The usual
dosage for a dispersant is 10 ppm. Dispersants keep fine suspended solids from coagulating and
coming down on the membrane surface. Proper use of dispersants can minimize fouling due to
problem particulates that are difficult to prefilter.

Acid Injection
Adjusting the pH of the feed water is another way to control calcium carbonate scaling. The net effect
of lowering the feed pH with acid injection is to convert bicarbonate alkalinity to carbon dioxide and
thereby prevent the formation of calcium carbonate. For reasons of handling and safety, acid
injection is not used for residential or small commercial systems.

Reduce Recovery
Membrane recovery is defined as the ratio of permeate flow to feed flow for that membrane.
Recovery can be reduced by increasing the feed flow. Another way to reduce recovery is to decrease
the operating pressure. Lower operating pressure produces a lower amount of permeate. If the feed
flow can be maintained near the original value, then a lower recovery is obtained.
The effect of lower recovery is to reduce the overall concentration of all substances in the reverse
osmosis system. More favorable boundary layer conditions are also achieved by reducing the system
recovery.

Membrane Cleaning
Even with all the preventative care given to a reverse osmosis system, some fouling of the
membranes will take place. Cleaning of the membranes can improve membrane performance.
Membranes can be cleaned using Cleaning Solutions approved by the membrane manufacturer. It is
not economical to clean membranes used in the residential reverse osmosis systems.
Details of membrane cleaning can be found on this site as well - Click Here to link.

Conclusions
Membrane fouling and scaling can be minimized by proper design and operating conditions.

11/25/2016 3:13 PM

Fouling Solutions

3 of 3

http://www.watertreatmentguide.com/membrane_fouling_solutions.htm

Important variables that control the membrane fouling must be considered in designing an operating
the reverse osmosis system.

Applied Membranes Product Selection Links:


[Reverse Osmosis Membranes] [Reverse Osmosis Systems][Home RO Systems][Seawater Desalination Reverse Osmosis Systems] [Media Filters, Carbon Filters, Water
Softeners, Etc.] [RO Filters & Housings] [RO Membrane Housings/Pressure Vessels] [Residential RO Components] [Commercial RO Components] [RO Pumps]
[Membrane Chemicals] [Ultravioloet (UV) Systems] [Ozone][Water Quality Testers (SDI)]

All Content on this site is intended for informational purposes for experienced water treatment professionals only. Applied Membranes, Inc. does not assume any
liability for any damages caused by the misapplication or misinterpretation of any of the information contained on this website.
Applied Membranes, Inc. 2007

11/25/2016 3:13 PM

You might also like