Polarization cell protects against induced AC current and ground fault current on buried pipelines. Polarisation
cells permit low-level voltage of cathodic protection to uniform flow and prevent hazardous voltages. Polarization
cell consist of multiple plates of steel arranged, fixed and immersed in 30% KOH (Potassium Hydroxide) solution.
Specially selected oil layer stop the evaporation of solution to some extend. It is advisable to verify the solution
level periodically. Polarization cell is fitted in transparent body to check solution level. Normal storage of cell does
not have any internal voltage and act as a grounding switch in presence of high voltage. Polarisation cell works
on electrochemical principle. Installed plates with large surface area polarize and allow in developing safe DC
voltage suitable for cathodic protection. As the voltage increases from DC or AC voltage, the polarisation film
breaks and polarization cell conduct current. Specially designed polarization cells have properties to retain
solution level to the maximum period with specially added floating oil. Polarisation cells are designed to protect
personnel and equipment from electrical disturbances
Polarisation cells control the flow of potentially dangerous AC and DC current in buried surface protected oil &
gas, water pipelines on the buried metallic structures. Grounding cells needs to be installed with high precaution
of gas ventilation. Improper installation could produce hazardous gases resulting to cause explosion and harmful
to operators. The polrization cells are safe while using as per the rated capacity given in the information section
to prevent corrosion
thickness of the polarization gas film to increase. When the leakage threshold is
exceeded, the film starts to break down and the cell resistance quickly decreases as
the applied voltage increases. AC voltages and higher DC voltages see the Kirk Cell
as a dead short. Galvanized steel enclosures are offered for exterior or interior
installations of the cell.
The Kirk Cell comes in three different models: K-50, K-25 and K-5A. All models are
available with enclosures on request.
DIMENSIONS
Height to top of lid
Overall height
Width at bottom
Width at top
Depth at bottom
Depth at top
6 3/4
8 1/4
4 5/16
5 1/4
4 5/16
5 1/4
As the applied Electromagnetic Field (EMF) across the cell terminals increases,
current flow through the Kirk Cell will increase in general agreement with the data in
the Performance tables below. Actual current flow will vary with ambient conditions
including but not limited to: temperature, solution concentration and age.
100ua
1ma
2ma
3ma
4ma
5ma
6ma
7ma
3900
640
355
262
210
194
200
180
1.30
1.34
1.42
1.48
1.70
1.72
1.73
1.73
1.74
1.77
1.87
1.90
1.99
2.10
2.85
4.85
8ma
9ma
10ma
15ma
20ma
25ma
30ma
40ma
50ma
100ma
500ma
1A
5A
10A
100A
500A
163
148
142
99
85
69
58
43
35
18
3.7
1.9
0.4
0.21
0.029
0.0097
500ma
1A
5A
10A
50A
100A
500A
0.60
0.38
0.13
0.09
0.02
0.015
0.0076
*Leakage threshold
15 1/8
16 3/4
11 1/8
12 1/16
9 7/16
10 1/16
As the applied Electromagnetic Field (EMF) across the cell terminals increases,
current flow through the Kirk Cell will increase in general agreement with the data in
the Performance tables below. Actual current flow will vary with ambient conditions
including but not limited to: temperature, solution concentration and age.
100ua
1ma
2ma
3ma
4ma
5ma
6ma
7ma
8ma
9ma
10ma
15ma
20ma
25ma
30ma
40ma
50ma
100ma
500ma
1A
5A
10A
2750
470
260
187
145
126
122
113
103
94
88
63
50
43
42
39
33
17
3.4
1.8
0.37
0.19
0.5A
1A
0.04
0.04
0.06
0.30
5A
10A
0.01
0.03
*Leakage threshold
100ua
1ma
2ma
3ma
4ma
5ma
6ma
7ma
8ma
9ma
10ma
15ma
20ma
25ma
30ma
40ma
50ma
100ma
500ma
1A
5A
10A
100A
500A
1KA
1500
380
210
150
115
96
83
74
66
61
59
46
43
37
33
29
24
13
3.4
1.8
0.36
0.19
0.022
0.053
0.0032
500ma
1A
5A
10A
50A
100A
500A
14KA
38.5KA
44.0KA
52.5KA
58.0KA
64.0KA
0.02
0.02
0.01
0.02
0.012
0.0062
0.0026
0.00076
0.00032
0.00032
0.00029
0.00029
0.00031