Professional Documents
Culture Documents
-24DC/URML4/3X1/1X2/B
Safety relay as contact extension for emergency
stop relays, safety door switches, and light grids
Data sheet
105430_en_01
1
Description
Features
Contact extension
Suitable up to category4, PLe (ENISO13849-1),
SILCL3 (EN62061)
Single or two channel operation
3 undelayed enabling current paths
1 undelayed signaling current path
Option of screw or spring-cage terminal blocks for
plug-in
PSR-...-24DC/URML4/3X1/1X2/B
Table of contents
Description .............................................................................................................................. 1
Derating................................................................................................................................... 6
Safety notes............................................................................................................................. 7
Diagnostics.............................................................................................................................. 8
10
105430_en_01
PHOENIX CONTACT
PSR-...-24DC/URML4/3X1/1X2/B
Ordering data
Description
Type
Order No.
Pcs. / Pkt.
Single or two-channel contact extension for OSSD signals (e.g., light grid),
3 N/O contacts, 1 N/C contact, up to Cat. 4 PL e according to EN ISO
13849, SIL 3 according to EN 62061, plug-in screw terminal blocks, width:
22.5 mm
PSR-SCP-24DC/URML4/3X1/1X2/B
2903583
Single or two-channel contact extension for OSSD signals (e.g., light grid),
3 N/O contacts, 1 N/C contact, up to Cat. 4 PL e according to EN ISO
13849, SIL 3 according to EN 62061, plug-in spring-cage terminal blocks,
width: 22.5 mm
PSR-SPP-24DC/URML4/3X1/1X2/B
2903584
Documentation
Type
Order No.
Pcs. / Pkt.
2888712
105430_en_01
PHOENIX CONTACT
PSR-...-24DC/URML4/3X1/1X2/B
Technical data
Input data
Nominal input voltage UN
24 V DC
70 mA DC
24 V DC
25 ms (man. start)
10 ms
Recovery time
1s
Output data
Contact type
Contact material
AgSnO2
15 V AC/DC
250 V AC/DC
6A
25 mA
0.4 W
6 A (24 V DC)
5 A (230 V AC)
3 A (24 V (DC13))
3 A (230 V (AC 15))
Output fuse
General data
Relay type
Nominal operating mode
Degree of protection
IP20
IP54
Mounting position
any
Mounting type
Type of housing
250 V
105430_en_01
PHOENIX CONTACT
PSR-...-24DC/URML4/3X1/1X2/B
General data
Rated surge voltage/insulation
Pollution degree
III
Dimensions
Screw connection
Spring-cage connection
WxHxD
22.5 x 99 x 114.5 mm
Connection data
Screw connection
Spring-cage connection
24 ... 12
24 ... 16
Stripping length
7 mm
8 mm
Ambient conditions
Ambient temperature (operation)
-20 C ... 55 C
-40 C ... 70 C
Certification / Approvals
Approvals
Safety data
Stop category according to IEC 60204
PFHd
5.56 x 10-10
Demand rate
< 12 Months
240 Months
Duration of use
240 Months
Data only applies if the safety function is demanded at least once a year and the signal contact is read back.
The specifications apply assuming the following calculation basis
B10d
dop
365.25 Days
hop
24 h
tCycle
3600 s
MTTFd
17913.5 Years
PFDavg
1,50 x 10-4
75 Months
Duration of use
240 Months
Performance level
CCF
Passed
Duration of use
240 Months
Data only applies if the safety function is demanded at least once a year and the signal contact is read back.
The specifications apply assuming the following calculation basis
105430_en_01
PHOENIX CONTACT
PSR-...-24DC/URML4/3X1/1X2/B
dop
365.25 Days
hop
24 h
tCycle
3600 s
23
33
41
Derating
S12
6
ITH [A2]
K1
Logic
K2
80
70
60
50
40
30
20
10
0
72
48
27
20
0V
Figure 1
S22
14
24
Block diagram
34
25
30
35
42
Figure 2
40
45
50
55
60
TA [C]
Derating curve
Key:
Designation
0V
S12/S22
13/14
23/24
33/34
41/42
105430_en_01
Explanation
Supply voltage
Input circuit
Enabling current paths
Signaling current path
PHOENIX CONTACT
PSR-...-24DC/URML4/3X1/1X2/B
Safety notes
WARNING: Risk of electric shock
During operation, parts of electrical switching
devices carry hazardous voltages.
Before working on the switching device, disconnect the power.
Please observe the safety regulations of electrical engineering and industrial safety and liability associations!
Disregarding these safety regulations may result in death, serious personal injury or damage to equipment.
Startup, mounting, modifications, and upgrades should only be carried out by a skilled
electrical engineer!
WARNING: Risk of automatic machine restart!
For emergency stop applications, the machine must be prevented from restarting automatically by a higher-level control system.
Protective covers must not be removed when
operating electrical switching devices.
WARNING: Danger due to faulty devices!
The devices may be damaged following an error and correct operation can no longer be ensured.
In the event of an error, replace the device immediately.
Repairs to the device, especially if the housing must be opened, may only be carried out
by the manufacturer or authorized persons.
Otherwise the warranty is invalidated.
NOTE: Risk of damage to equipment due
to incorrect installation
For reliable operation, the safety relay must
be installed in housing protected from dust
and humidity (IP54).
Carry out wiring according to the application.
Refer to the Application examples section
for this.
105430_en_01
PHOENIX CONTACT
PSR-...-24DC/URML4/3X1/1X2/B
12
S
6
22
S
0V
0V
0V
22
22
12
12
K
1
1
K
P
S
P
S
-U
-U
M
L
M
L
41
41
24
14
23
14
23
13
34
13
34
33
42
33
42
24
41
41
13
APPROVALS
14
23
24
13 23 33
Serial No.
Order No.: 29 03 58 4
34
13 23 33
Serial No.
PSR-SPP- 24DC/URML4/3X1/1X2/B
42
24
PSR-SCP- 24DC/URML4/3X1/1X2/B
23
14
Order No.: 29 03 58 3
34
13
APPROVALS
42
33
33
41
14 24 34
41
14 24 34
42
42
Figure 3
Key:
Designation
1
2
3
4
5
6
7
Explanation
COMBICON plug-in screw terminal blocks
COMBICON plug-in spring-cage terminal blocks
Metal lock for mounting on the DIN rail
41/42 - signaling current path
13/14, 23/24, 33/34 - enabling current paths
S12/S22 - input circuit
0V - supply voltage connection
Diagnostics
For the diagnostic description, please refer to the application manual for PSR safety relays.
105430_en_01
PHOENIX CONTACT
PSR-...-24DC/URML4/3X1/1X2/B
10
Application examples
10.3
10.1
L+
(L1)
Transmitter
K3
Receiver
K4
OSSD1 OSSD2
S12
( )
L+
(L1)
EDM
13
S22
( )
23
33
41
FAIL-SAFE
SPS/PLC
K3
DO DO DI
PSR-...-24DC/URML4/3X1/1X2
K3
K4
K4
0V
14
24
34
42
24 V DC
K4
M
(N)
13
23
33
41
14
24
34
42
K3
PSR-...-24DC/URML4/3X1/1X2
K4
A2
Figure 4
10.2
S12 S22
( ) ( )
K3
K4
K3
M
(N)
Figure 6
L+
(L1)
LPSDO 8
V2/V3
PSDI 8
V2/V3
DO DO
DI
DI
K3
K4
S12 S22
( ) ( )
24 V DC
13
23
33
41
14
24
34
42
K3
PSR-...-24DC/URML4/3X1/1X2
K4
A2
K4
M
(N)
Figure 5
105430_en_01
K3