You are on page 1of 3

For Internal Purpose only

Huawei M2000 -NMS System


At first need to put site ID in search field

Select 2G BTS then it will come at left nevigation bar and select BSC for that specific site.

To check 2G traffic IP or TDM put command LST BTS and search specific BTS

Need to keep BTS index 175 from there and command to check 2G VLAN is LST BTSVLAN andn select index type by ID

command to check 2G capacity is LST IPPATH and select adj node ID as BTS index

When search any site 2G BTS shown as 1 , 3G NodeB shown as 2 or 3 and 4G eNodeB shown as L1

To check 3G node IP address, command is LST IPPATH ( no need to go to RNC like 2G , just right click on 3G nodeB and go to MML command)

To check 3G IP capacity , command is LST LR


To Check 3G VLAN ID , command is LST VLANMAP

To check any other node cascaded with 3G node, command is DSP ETHPORT

To check 4G IP capacity , select 4G node and right click and go to MML command and put LST LR

To check 4G VLAN ID , commamd is LST VLANMAP

To check 3G node active card then go to device Maintenance and double click on nodeB then you can find UTRP and UMPT slot number and from DSP Ethport command , you can figure out which slot is up ( UTRP or UMPT). UMPT having GE/FE0, GE/FE1,GE/FE2 and GE/FE3 ports and all electrical but UMPT card having GE/FE0 (electrical), GE/FE1,GE/FE2 and GE/FE3(Optical) ports

2G BTS always using GTMU card with FE0 port (electrical)


4G always using UMPT card with GE/FE0 (electrical), GE/FE1,GE/FE2 and GE/FE3(Optical) ports

You might also like