Professional Documents
Culture Documents
File
MA.TP2.02+
UNIT 10 5 System Documentation
MA File
Volume MA.TP2.05+
Steam Turbine 8 Special Tools and Devices 8.0 - 8.3
SIEMENS AG - 2012-02-24
File
Project Ident Document type Volume-UNID MA.TP2.08+
9 Spare Parts 9.4 (Part 1)
IN1005 &MDC099 483440515
File
MA.TP2.10+
10 Contract Drawings 10.1
Volume title sheet, table of contents (volume), revision
sheets, file title sheet (1st file)
File
MA.TP2.11+
Raichur Power Corporation Ltd 10 Contract Drawings 10.2
2 X 800 MW YERAMARUS THERMAL POWER STATION
File
MA.TP2.12+
UNIT 10 10 Contract Drawings 10.3
MA File
Volume MA.TP2.15+
Steam Turbine 11 Mechanical Systems and Components 11.0 -
11.3
File
MA.TP2.17-
11 Mechanical Systems and Components 11.8 -
11.9
File
File
File
Raichur Power Corporation Limited
2 X 800 MW YERAMARUS THERMAL POWER STATION
Unit 10
Volume Ident: MA.TP2
Volume: MA Steam Turbine
Table of Contents (Volume)
File: MA.TP2.01
1-4 General / Descriptions
TAB-Sheet: 1 General User Information
UNID Title Rev. Date of Issue
483575149 General User Information - 2012-02-22
TAB-Sheet: 2 General Safety Information
UNID Title Rev. Date of Issue
483575156 General Safety Information - 2012-02-22
TAB-Sheet: 3 Technical Data
UNID Title Rev. Date of Issue
483575163 Table of Contents Chapter 3 - 2012-02-22
TAB-Sheet: 3.1 Design Data
UNID Title Rev. Date of Issue
483575170 Design Data - 2012-02-22
TAB-Sheet: 3.2 Limit- and Setting Values
UNID Title Rev. Date of Issue
483575187 Limit- and Setting Values - 2012-02-22
TAB-Sheet: 3.3 Lists
UNID Title Rev. Date of Issue
483575194 Lists - 2012-02-22
TAB-Sheet: 3.4 Specifications
UNID Title Rev. Date of Issue
483575200 Specifications - 2012-02-22
TAB-Sheet: 3.5 Thermal Insulation
UNID Title Rev. Date of Issue
483575217 Thermal Insulation - 2012-02-22
TAB-Sheet: 4 Description of Components
UNID Title Rev. Date of Issue
483575224 Table of Contents Chapter 4 - 2012-02-22
TAB-Sheet: 4.1 Main Components, Overview
UNID Title Rev. Date of Issue
483575231 Main Components, Overview - 2012-02-22
TAB-Sheet: 4.2 H Turbine
UNID Title Rev. Date of Issue
483575248 H Turbine - 2012-02-22
TAB-Sheet: 4.3 I Turbine
UNID Title Rev. Date of Issue
483575255 I Turbine - 2012-02-22
TAB-Sheet: 4.4 Main Valves
UNID Title Rev. Date of Issue
483575262 Main Valves - 2012-02-22
TAB-Sheet: 4.5 L Turbine
UNID Title Rev. Date of Issue
483575279 L Turbine - 2012-02-22
File: MA.TP2.02
5 System Documentation
TAB-Sheet: 5 General / System Documentation
UNID Title Rev. Date of Issue
483535815 General / System Documentation - 2012-02-16
TAB-Sheet: 5.1 Steam Turbine Plant
UNID Title Rev. Date of Issue
483535822 Steam Turbine Plant - 2012-02-16
TAB-Sheet: 5.2 Oil System
UNID Title Rev. Date of Issue
483535839 Oil System - 2012-02-16
TAB-Sheet: 5.3 Control Media System
UNID Title Rev. Date of Issue
483535846 Control Media System - 2012-02-16
TAB-Sheet: 5.4 Steam Turbine
UNID Title Rev. Date of Issue
483535853 Steam Turbine - 2012-02-16
TAB-Sheet: 5.5 Drain System
UNID Title Rev. Date of Issue
483535860 Drain System - 2012-02-16
TAB-Sheet: 5.6 Condensing Plant
UNID Title Rev. Date of Issue
483535877 Condensing Plant - 2012-02-16
TAB-Sheet: 5.7 Bypass System
UNID Title Rev. Date of Issue
483535884 Bypass System - 2012-02-16
TAB-Sheet: 5.8 Steam Piping System
UNID Title Rev. Date of Issue
483535891 Steam Piping System - 2012-02-16
TAB-Sheet: 5.9 Steam Extractions
UNID Title Rev. Date of Issue
483535907 Steam Extractions - 2012-02-16
File: MA.TP2.03
6 Operating Instructions, Alarm Annunciations
TAB-Sheet: 6 General / Operating Instructions, Alarm Annunciations
UNID Title Rev. Date of Issue
483535914 General / Operating Instructions, Alarm Annunciations - 2012-02-16
TAB-Sheet: 6.1 Steam Turbine Plant
UNID Title Rev. Date of Issue
483535921 Steam Turbine Plant - 2012-02-16
TAB-Sheet: 6.2 Oil System
UNID Title Rev. Date of Issue
483535938 Oil System - 2012-02-16
TAB-Sheet: 6.3 Control Media System
UNID Title Rev. Date of Issue
483535945 Control Media System - 2012-02-16
TAB-Sheet: 6.4 Steam Turbine
UNID Title Rev. Date of Issue
File: MA.TP2.04
7 Test and Maintenance Instructions
TAB-Sheet: 7 General / Test and Maintenance Instructions
UNID Title Rev. Date of Issue
483535983 General / Test and Maintenance Instructions - 2012-02-16
TAB-Sheet: 7.1 Steam Turbine Plant
UNID Title Rev. Date of Issue
483535990 Steam Turbine Plant - 2012-02-16
TAB-Sheet: 7.2 Oil System
UNID Title Rev. Date of Issue
483536003 Oil System - 2012-02-16
TAB-Sheet: 7.3 Control Media System
UNID Title Rev. Date of Issue
483536010 Control Media System - 2012-02-16
TAB-Sheet: 7.4 Steam Turbine
UNID Title Rev. Date of Issue
483536027 Steam Turbine - 2012-02-16
TAB-Sheet: 7.5 Drain System
UNID Title Rev. Date of Issue
483536034 Drain System - 2012-02-16
TAB-Sheet: 7.6 Condensing Plant
UNID Title Rev. Date of Issue
483536041 Condensing Plant - 2012-02-16
TAB-Sheet: 7.7 Test Records
UNID Title Rev. Date of Issue
483536058 Test Records - 2012-02-16
File: MA.TP2.05
8 Special Tools and Devices 8.0 - 8.3
TAB-Sheet: 8 General / Tools and Devices
UNID Title Rev. Date of Issue
483497472 Table of Contents - 2012-02-20
TAB-Sheet: 8.1 Tools and Devices
UNID Title Rev. Date of Issue
483497489 Tools and Devices - 2012-02-16
TAB-Sheet: 8.2 Lifting device
TAB-Sheet: 8.2.1 Lifting Device for Rotor
UNID Title Rev. Date of Issue
483497496 Lifting Device for Rotor - 2012-02-16
TAB-Sheet: 8.2.2 Lifting Device for Casing of Shaft Sealing
UNID Title Rev. Date of Issue
483497502 Lifting Device for Casing of Shaft Sealing - 2012-02-16
TAB-Sheet: 8.3 Hydraulic cylinder for erection
UNID Title Rev. Date of Issue
483497519 Hydraulic Cylinder for Erection - 2012-02-16
File: MA.TP2.06
8 Special Tools and Devices 8.4 - 8.11
TAB-Sheet: 8.4 Hydraulic Cylinder as temporary support during inspection
UNID Title Rev. Date of Issue
483497526 Hydraulic Cylinder as temporary Support during Inspection - 2012-02-16
TAB-Sheet: 8.5 Certificates of ropes and chains
UNID Title Rev. Date of Issue
483497533 Certificates of Ropes - 2012-02-20
TAB-Sheet: 8.6 Certificates of load shackle and swivel eye
UNID Title Rev. Date of Issue
483497540 Certificates of Load Shackle and Swivel Eye - 2012-02-20
TAB-Sheet: 8.7 Assembly Instructions for HP Turbine
UNID Title Rev. Date of Issue
483497953 Assembly Instructions of HP Turbine - 2012-02-16
TAB-Sheet: 8.8 Gas Heating Device for Heating Bolts
UNID Title Rev. Date of Issue
483497960 Gas Heating Device for Heating Bolts - 2012-02-16
TAB-Sheet: 8.9 Heating Device for Breech Nut
UNID Title Rev. Date of Issue
483497977 Heating Device for Breech Nut - 2012-02-16
TAB-Sheet: 8.10 Support of Breech Nut
UNID Title Rev. Date of Issue
483497984 Support of Breech Nut - 2012-02-16
TAB-Sheet: 8.11 Stretching Device for Breech Nut
UNID Title Rev. Date of Issue
483497991 Streching Device for Breech Nut - 2012-02-16
File: MA.TP2.07
9 Spare Parts 9.0 - 9.3
TAB-Sheet: 9 General / Spare Parts
UNID Title Rev. Date of Issue
483498554 Table of Contents - 2012-02-16
TAB-Sheet: 9.1 Overview Illustration, Design Groups
UNID Title Rev. Date of Issue
483498561 Overview Illustrations, Design Groups - 2012-02-16
TAB-Sheet: 9.2 Spare Parts Lists
UNID Title Rev. Date of Issue
483498578 Spare Parts Lists - 2012-02-16
TAB-Sheet: 9.3 List of Illustrations
UNID Title Rev. Date of Issue
483498585 List of Spare Parts Illustrations - 2012-02-16
File: MA.TP2.08
9 Spare Parts 9.4 (Part 1)
TAB-Sheet: 9.4.1 Spare Parts Illustrations (Part 1)
UNID Title Rev. Date of Issue
483498592 Spare Parts Illustrations (Part 1) - 2012-02-16
File: MA.TP2.09
9 Spare Parts 9.4 (Part 2)
TAB-Sheet: 9.4.2 Spare Parts Illustrations (Part 2)
UNID Title Rev. Date of Issue
File: MA.TP2.10
10 Contract Drawings 10.1
TAB-Sheet: 10 General / Contract Drawings
UNID Title Rev. Date of Issue
483446470 General / Contract Drawings - 2012-02-13
TAB-Sheet: 10.1 Contract Drawings Part 1
UNID Title Rev. Date of Issue
483382457 Dry-Air Equipment C 2007-09-18
483382464 Balance for Power Plant A 2007-09-26
483382471 Valve Complete D 2011-06-10
483382488 Valve Complete A 2011-06-08
483382495 Valve Complete A 2011-06-09
483382501 Longitudinal Section A 2011-09-01
472272660 Detail Diagram Bearing C 2009-12-18
472272677 Detail Diagram Hydraulic Motor B 2009-12-18
483382518 Arrgt of Endoscope Holes A 2011-05-16
483382525 Balancing at Power Plant A 2011-04-19
File: MA.TP2.11
10 Contract Drawings 10.2
TAB-Sheet: 10.2 Contract Drawings Part 2
UNID Title Rev. Date of Issue
483382532 Balancing at Power Plant C 2011-03-03
471223465 Graphical Symbols for Piping; Valves and Instrumentation B 2010-02-09
471223472 Graphical Symbols for Control Fluid A 2009-09-28
472272448 Detail Diagram HP1 Stop Valve Actuator A 2009-12-18
472272554 Detail Diagram HP2 Stop Valve Actuator A 2009-12-18
472272615 Detail Diagram IP1 Stop Valve Actuator A 2009-12-18
472272622 Detail Diagram IP2 Stop Valve Actuator A 2009-12-18
472272561 Detail Diagram HP1 Govern Valve Actuator A 2009-12-18
472272578 Detail Diagram HP2 Govern Valve Actuator A 2009-12-18
472272639 Detail Diagram IP1 Govern Valve Actuator A 2009-12-18
File: MA.TP2.12
10 Contract Drawings 10.3
TAB-Sheet: 10.3 Contract Drawings Part 3
UNID Title Rev. Date of Issue
472272646 Detail Diagram IP2 Govern Valve Actuator A 2009-12-18
472272592 Component Diagram Overload Valve Actuator A 2009-12-18
472272585 Detail Diagram Main Steam Stop and Control Valve A 2009-12-18
472272653 Detail Diagram Reheat Steam Stop and Control Valve A 2009-12-18
472272608 Detail Diagram Overload Valve A 2009-12-18
476074017 Detail Diagram Water Injection Valve for HRH Bypass A 2010-09-22
473594389 Data-sheet for Adjustment of Oil Throttle Vavlves A 2010-02-26
471164874 System Diagram Pressure Oil / Return Flow D 2012-01-31
471164881 System Diagram Oil Vapor Exhaust C 2010-08-31
471164898 System Diagram Oil Discharge B 2010-02-09
File: MA.TP2.13
10 Contract Drawings 10.4
TAB-Sheet: 10.4 Contract Drawings Part 4
UNID Title Rev. Date of Issue
File: MA.TP2.14
10 Contract Drawings 10.5
TAB-Sheet: 10.5 Contract Drawings Part 5
UNID Title Rev. Date of Issue
471180782 System Diagram Gland Steam G 2012-01-31
471164942 System Diagram U-Ring / Spindle Leakoff Steam B 2010-02-11
471217761 System Diagram Turbine Drain System E 2010-09-22
471217792 System Diagram IP-Bypass steam C 2011-01-18
471217778 System Diagram Condensation F 2010-10-20
471217723 System Diagram HP-, IP-, LP-Turbine O 2011-08-08
472272684 Detail Diagram Servomotor of Hot Reheat Bypass Valve 1 A 2009-12-18
472272691 Detail Diagram Servomotor of Hot Reheat Bypass Valve 2 A 2009-12-18
471217785 System Diagram Control Air System D 2011-08-08
File: MA.TP2.15
11 Mechanical Systems and Components 11.0 - 11.3
TAB-Sheet: 11 General / Mechanical Systems and Components
UNID Title Rev. Date of Issue
483440522 Table of Contents Chapter 11 - 2012-02-16
TAB-Sheet: 11.1 AGP / Hydraulic Turning Gear
UNID Title Rev. Date of Issue
483440539 Table of Contents - 2012-02-13
483440546 Radial Piston Motor - Foreword - 2012-02-13
483440553 Radial Piston Motor - Technical Information - 2012-02-13
483440560 Overrunnning Clutch - 2012-02-13
483440577 Drawing - 2012-02-13
TAB-Sheet: 11.2 Fike / Explosion Vent
UNID Title Rev. Date of Issue
483440584 Explosion Vent - 2012-02-13
TAB-Sheet: 11.3 Bosch Rexroth AG / Actuators for Stop and Control Valves
UNID Title Rev. Date of Issue
483440591 Table of Contents - 2012-02-13
483440607 Hydraulic Actuator - 2012-02-13
483440614 Poppet direct valve direct operated - 2012-02-13
483440621 Poppet direct valve direct operated - 2012-02-13
483440638 Logic cartridge valve - 2012-02-13
483440645 Servo directional valve - 2012-02-13
483440652 Servo directional valve - 2012-02-13
483440669 Check valve - 2012-02-13
483440676 Pressure filter - 2012-02-13
483440683 Displacement transducer - 2012-02-13
483440690 Proximity switch - 2012-02-13
File: MA.TP2.16
11 Mechanical Systems and Components 11.4 - 11.7
TAB-Sheet: 11.4 Welland & Tuxhorn AG / Shut-off Valve for Steam
UNID Title Rev. Date of Issue
483440706 Table of Contents - 2012-02-13
TAB-Sheet: 11.4.1 Shut-off Valve for Steam / Operation Instruction Valve
UNID Title Rev. Date of Issue
483440713 Shut-off Valve for Steam - 2012-02-13
TAB-Sheet: 11.4.2 Shut-off Valve for Steam / Documents of Parts' Suppliers
UNID Title Rev. Date of Issue
483440720 Actuator - 2012-02-13
483440737 Air Set - 2012-02-13
483440744 Solenoid Valve - 2012-02-13
483440751 Proximity Switch - 2012-02-13
TAB-Sheet: 11.5 Sempell AG / Non Return Valve with Actuator
UNID Title Rev. Date of Issue
483440768 Table of Contents - 2012-02-13
483440775 Non Return Valve with Actuator - 2012-02-13
483440782 Actuator - 2012-02-13
483440799 Proximity switch - 2012-02-13
483440805 3/2 directional control valve - 2012-02-13
483440812 Standard silencer - 2012-02-13
483440829 Pressure regulator - 2012-02-13
483440836 3/2 pneumeumatic control valve - 2012-02-13
483440843 Quick venting valve - 2012-02-13
TAB-Sheet: 11.6 Sempell AG / Non Return Valve
UNID Title Rev. Date of Issue
483440850 Table of Contents - 2012-02-13
483440867 Drawing - 2012-02-13
483440874 Operating Instruction - 2012-02-13
483440881 Declaration of Conformity - 2012-02-13
483440898 Transmitter - 2012-02-13
TAB-Sheet: 11.7 Stahlberg GmbH / Thermocouples & Measuring Insert
UNID Title Rev. Date of Issue
483440904 Table of Contents - 2012-02-13
483440911 Thermocouple with washer disc - 2012-02-13
483440928 Thermocouple without washer disc - 2012-02-13
483440935 Measuring Insert according to KUN672.25 - 2012-02-13
483440942 Measuring Insert according to KUN 672.20 - 2012-02-13
File: MA.TP2.17
11 Mechanical Systems and Components 11.8 - 11.9
TAB-Sheet: 11.8 Vibrometer / Vibration Pickups
UNID Title Rev. Date of Issue
483496314 Table of Contents - 2012-02-16
483496321 Absolute Vibration Probe CA 201 - 2012-02-16
483496338 Relative Vibration Probe TQ 402 - 2012-02-16
483496345 Absolute Vibration Probe CA 202 - 2012-02-16
TAB-Sheet: 11.9 Braun GMBH / Speed Probe
UNID Title Rev. Date of Issue
483496451 Speed Probe - 2012-02-16
Operating & Mainte- Operating & Mainte- Operating & Mainte- Operating & Mainte- Operating & Mainte-
nance Manuals nance Manuals nance Manuals nance Manuals nance Manuals
MA MA MA MA MA
Steam Turbine Steam Turbine Steam Turbine Steam Turbine Steam Turbine
1-4 General / Descriptions 1-4 General / Descriptions 1-4 General / Descriptions 1-4 General / Descriptions 1-4 General / Descriptions
2 x 800 MW
YERAMARUS THERMAL POWER STATION
TAB-Sheet
Unit 10 08 MAV - Lube and Lifting Oil System
(Phase A/B)
TAB-Sheet
TAB-Sheet
File- MA
name Commissioning Manual 11 MYA - Steam Turbine Controller (Phase
A/B)
Steam Turbine
Part 2
TAB-Sheet
TAB-Sheet
13 Commissioning Documents Phase C
Department
E F PR SU OM TAB-Sheet
QRD 2 14 Further Commissioning Documents
Originator Revision Issue Date
SIEMENS AG A 2012-03-29
TAB-Sheet
Project Ident Document type UNID
TAB-Sheet
User Information
Identification Basics Document Documentation Sections Subdivided to
Classification
Manual Groups
Technical Customer Documentation T Design Documentation TD
Approval Documentation TA
1 General .TP1.
2 Steam Turbine,
Erection Manuals, Condenser .TP2.
TE
Commissioning, Manuals
Classification Examples:
.TS3. = Site Documentation
--- Prepared acc. to scope of supply and contract Gas Turbine
* In manual form only, if contractually required .TE8. = Erection Instructions
Mechanical Components
.TEP5. = Combined Erection
and Oper. & Product
Manual, Electrical
Components
These documents do not claim to constitute a complete description of all system or component details or to cover all conceivable
construction, initial commissioning, operating, maintenance or repair conditions in connection with the work to be performed. Such
activities must therefore only be planned or performed by sufficiently trained personnel and the work be carried out in strict compliance
with these documents. Non-observance of this requirement can result in damage to property or in personal injury. Use of a system or
component together with products supplied by other companies that do not comprise part of the system or component requires the
express prior approval of the IN1005 BHEL 800MW Yeramarus Project supplier.
Anl-4-Vers6-V-AW-P03-025.doc This page is subject to handling restrictions as stated on the title page or the
first page, respectively.
Siemens . Energy Sector
Raichur Power Corporation Limited
2 X 800 MW YERAMARUS THERMAL POWER STATION
Unit 10
File Ident: MA.TE2.COM.02
File: MA Part 2
Table of Contents (File)
Unit 10
File Ident: MA.TP2.01
File: MA 1-4 General / Descriptions
This information must be read before operation and main- It is absolutely essential to safe plant operation, that per-
tenance. If the content seems unclear or incomplete, please sonnel have read, understood and follow the safety instruc-
contact Siemens AG before starting any work. tions in this manual.
This manual contains information on operation and daily documents, please notify us in writing specifying the complete
steam turbine maintenance. It is taken as read, that only spe- document number (e.g.: 1.1.1-04000-00007/1 1008 for this
Copyright Siemens AG 2008 - All Rights Reserved
The Product and Operating Documentation, the Pur- NNN4 Document Key
chased Parts Documentation volumes and the Contract Doc-
0NN General documentation
umentation volumes have their own Table of Contents even
if the documentation is distributed over several folders. You 1NN Technical data, system and compo-
should use the table of contents to check that the manuals nent descriptions
are complete and that the corresponding part of the manual 2NN P&IDs
is valid. If the manuals should not be complete or contain
3NN Functional descriptions
wrong or obsolete documentation please contact us at the
address given in Document 1.1.1-08000. 4NN Procedural and Operating Instruc-
tions
5NN Alarm annunciations
ihres Inhaltes nicht gestattet, soweit nicht ausdrcklich zugestanden.
Weitergabe sowie Vervielfltigung dieser Unterlage, Verwertung und Mitteilung
NNNN7A8 F French
Sp Spanish
N1 Document Key
The remaining part of the document key are for revision
2 Operating Documentation of the Operating Documentation and for manufacturer in-
house purposes.
N2 Section Key
1 System documentation Publication Numbers for Product
2 I&C documentation
Documentation
3 Operating instructions, alarm annuncia- The identification number is made up of the section num-
tions ber and additional references:
1.1.4-xxxxx-yyyyy / a-n The Operating Documentation does not deal with specific
types of control tiles or systems or with specific types or con-
Page a of n
figurations or handling of the plant operations monitoring fa-
Variant cilities installed.
1.1.1-05000
Warning!
Copyright Siemens AG 2009 - All Rights Reserved
MA &MAA
Purchased Parts Documentation
With regard to supplier documentation, cross-reference
will be made to the table of contents of the Purchased Parts
Handhabung: RESTRIKTIV
Scope of the Operating Documentation volume. The documentation is filed by KKS code to ensure
that documents can be found fast and reliably.
For the purpose of operation, it is assumed that the com-
mands necessary for operation of the plant can be given from
the control tiles in the control room or via computer-assisted Contract Drawings
systems. The KKS abbreviations used in the system and compo-
nent diagrams are explained in detail in Document
1.1.1-06000.
Chapter 1
General User Information
Title Identification No. Date
Preface 1.1.1-04000-00007 1008E
Notes on the Use of the Manual 1.1.1-05000-00003 0309E
Table of Contents Chapter 1 1.1.1-02001-12565 0212E
Table of Contents Chapter 2 1.1.1-02002-12565 0212E
Table of Contents Chapter 3 1.1.1-02003-12565 0212E
Table of Contents Chapter 4 1.1.1-02004-12565 0212E
Table of Contents Chapter 5 1.1.1-02005-12565 0212E
Table of Contents Chapter 6 1.1.1-02006-12565 0212E
Table of Contents Chapter 7 1.1.1-02007-12565 0212E
Table of Contents Chapter 8 1.1.1-02008-12565 0212E
Table of Contents Chapter 9 1.1.1-02009-12565 0212E
Table of Contents Chapter 10 1.1.1-02010-12565 0212E
Table of Contents Chapter 11 1.1.1-02011-12565 0112E
Identification System for Power Plants 1.1.1-06000-00001 0212E
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
Title
Chapter 2
Energy Sector
Steam Turbines
Safety Instructions
Siemens AG
General Safety Information
General User Information
MA &MAB019
Table of Contents Chapter 2
Identification No.
1.1.2-01000-00003
1.1.1-02002-12565
Date
0707E
0212E
0212E
1.1.1-02002-12565 / 1-1
Steam Turbines
General User Information Table of Contents Chapter 3
Chapter 3
Technical Data
Title Identification No. Date
Table of Contents Chapter 3 1.1.1-02003-12565 0212E
Chapter 4
Description of Components
Title Identification No. Date
Table of Contents Chapter 4 1.1.1-02004-12565 0212E
Title
Energy Sector
Steam Turbines
Siemens AG
Hydraulic Turning Gear
General User Information
MA &MAB019
Table of Contents Chapter 4
Identification No.
1.1.4-32000-00014
Date
0806E
0212E
1.1.1-02004-12565 / 2-2
Steam Turbines
Operating Documentation Table of Contents Chapter 5
Chapter 5
System Documentation
Index
Significant Operating Events 2-1-MA1-125 M0003 1102E
Notes
Lubricating Oil System 2-1-MA1-131 M0016 0905E
Copyright Siemens AG 2012 - All Rights Reserved
System Description
Lifting Oil System 2-1-MA1-132 M0009 0611E
of a utility model or design, are reserved.
System Description
Oil Vapor Extraction System 2-1-MA1-133 M0034 0811E
System Description
Oil Discharge and Vent Equipment 2-1-MA1-137 M0001 1008E
System Description
Oil Conditioning 2-1-MA1-140 M0003 0711E
System Description
Oil Supply Emergency Operation 2-1-MA1-334 M0041 0811E
Functional Description
Lube Oil Pressure Trip Device 2-1-MA1-370 M0001 0905E
Functional Description
Main Oil Tank Level Protection 2-1-MA1-376 M0002 0407E
Functional Description
Operating of the Turning Gear 2-1-MA1-390 M0001 0807E
Functional Description
Class: FOR INTERNAL USE ONLY
Functional Description
Actuating Turbine Valves 2-1-MA3-343 M0011 0109E
Functional Description
of a utility model or design, are reserved.
Procedural Instruction
Journal Bearing 2-1-MA3-464 M0001 1090E
Procedural Instruction
Copyright Siemens AG 2012 - All Rights Reserved
Work Report
Functional Description
Temperature Monitoring Equipment for Hot Reheat Line (HIGH) 2-1-MA7-383 M0003 0309E
Functional Description
of a utility model or design, are reserved.
Chapter 6
Operating Instructions, Alarm Annunciations
Chapter 7
Test and Maintenance Instructions
Inspection Plan
Inspection Plan for Turbine Valves (excl. Actuator) 2-4-M-622 M0002 0411E
Inspection Plan
Measures for Functional Safety 2-4-M-655 12565 0212E
Copyright Siemens AG 2012 - All Rights Reserved
Maintenance Worksheet
Main Oil Tank 2-4-MA1-755 M0001 1109E
Maintenance Worksheet
Copyright Siemens AG 2012 - All Rights Reserved
Maintenance Instruction
Condenser
Energy Sector
STPR Form
Steam Turbines
Siemens AG
Maintenance Schedule
General User Information
MA &MAB019
0.8.0-60311
0.8.0-60301
2-4-MA5-706
Table of Contents Chapter 7
00001
00001
M0001
0110E
0108E
0211E
0212E
1.1.1-02007-12565 / 3-3
Steam Turbines
General User Information Table of Contents Chapter 8
Chapter 8
Tools and Devices
Title Identification No. Date
Chapter 9
Spare Parts
Title Identification No. Date
Register 9.0 / General
Table of Contents Chapter 9 1.1.1-02009-12565 0212E
Preface 1.1.6-00020-00002 0904E
Chapter 10
Contract Drawings
Title Identification No. Date
Chapter 11
Mechanical Systems and Components
Title Identification No. Date
Table of Contents Chapter 11 1.1.1-02011-12565 0112E
List of Mechanical Systems and Components (ordered by identifier) 1.1.1-01500-12565 0112E
List of Mechanical Systems and Components (ordered by register) 1.1.1-02000-12565 0112E
Register 11.1
Hydraulic Turning Gear
Register 11.2
Explosion Vent
Register 11.3
Actuators for Stop and Control Valves
Register 11.4
Shut-off Valve for Steam
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
Register 11.5
Non Return Valve with Actuator
Copyright Siemens AG 2012 - All Rights Reserved
Register 11.6
Non Return Valve
of a utility model or design, are reserved.
Register 11.7
Thermocouples & Measuring Inserts
Register 11.8
Vibration Pickups
Register 11.9
Speed Probes
Class: FOR INTERNAL USE ONLY
1 Breakdown level 0
Structure of the Identifier
0MAD11 Breakdown level 1 (subdivided into 4 system
The KKS system lays down the method by which the
levels + Function Key F 0=0)
identifier is built up. An identifier consists of letters and num-
bers and is subdivided into four breakdown levels as shown CT014A Breakdown level 2 (subdivided into 3 equip-
below. ment levels)
M (Function Key F1) This letter identifies the main machine sets.
MA (Function Keys F1+F2) All parts of the steam turbine and its auxiliary systems are designated "MA" at
function key 1+2. For the generator "MK" is used.
D (Function Key F3) This letter designates the area to which the part belongs. "D" stands for the bear-
ings. See Table 1 for the letters.
11 (Function Key FN) This 2-digit number designates a system section. In this example the number "11"
stands for the first bearing of the steam turbine.
D Bearings
X Non electric control and protection equip-
G Condensing system ment, incl. fluid supply system
J Air removal system Y Electrical control and protection equipment
K Transmission gear between prime mover
and driven machine, incl. turning gear
Table 3: KKS Number Ranges for Valves, Pipes and Measuring Circuits
Number Valves: AA Pipes: BR Measuring circuits: C.
001-050 valves in main pipes valves, general main pipes binary and analog
measuring circuits
051-100
101-150 control valves /
dampers
151-190
191-199 safety valves suction and pressure re-
lief lines on safety valves
201-250 check valves not used automatic testing devi-
ces
251-299 hand operated valves
301-399 isolating equipment for measuring equip- pressure lines for meas- not used
ment urement
401-499 valves in drains and flushing pipes drains, flushing pipes, acceptance test
pressure suppression
pipes
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
Siemens AG Postfach 10 17 55
Energy Sector 45466 Mlheim an der Ruhr / Germany
Rheinstrae 100
45478 Mlheim an der Ruhr for packages and parcels:
Germany
Rheinstrae 100
For carload shipments:
45478 Mlheim an der Ruhr / Germany
Siemens AG
Energy Sector
45473 Mlheim an der Ruhr / Germany
Mlheim (Ruhr) - Styrum, Anschlussgleis
Class: FOR INTERNAL USE ONLY
Unit 10
File Ident: MA.TP2.01
File: MA 1-4 General / Descriptions
Title
Chapter 2
Energy Sector
Steam Turbines
Safety Instructions
Siemens AG
General Safety Information
General User Information
MA &MAB019
Table of Contents Chapter 2
Identification No.
1.1.2-01000-00003
1.1.1-02002-12565
Date
0707E
0212E
0212E
1.1.1-02002-12565 / 1-1
Steam Turbines
Safety Instruction General Safety Information
- Note!
tion 1.1.1-01000 Manual Survey for more information re-
Note! is used to identify any important information re-
garding the structure of the technical documentation.
garding particular procedures or the use of specific tools
of a utility model or design, are reserved.
As used in the technical documentation, the term steam or materials as well as any information relevant to ensure
turbine also refers to the auxiliary systems. maximum steam turbine efficiency.
- Prohibitive signs (circles outlined in red with black sym- To ensure normal and trouble-free operation of the tur-
bols on white background) e.g. bine it is necessary to comply with the operating instructions
as well as the inspection and maintenance intervals specified
No smoking! for the steam turbine.
Warning!
Risk of injury and equipment damage: Improper
Additional pictograms can be found in the technical doc- use of the steam turbine can adversely affect the
umentation. The meaning of these pictograms can be deter- (operational) safety of the steam turbine and re-
mined from the brief description of the type of danger which sult in personal injury and equipment damage.
is presented at the beginning of the safety notice. Many pic-
tograms indicate a specific danger (e.g. suspended loads or General Organization
an explosion hazard) and are used in place of the general
The following instructions must be followed to ensure safe
pictograms listed above.
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
- Identify on-scene incident commanders for such emer- - All prescriptive, probitive and warning signs must be du-
gency situations and provide requisite training (also in rable and must be clearly posted at the corresponding
First Aid). Ensure that an on-scene incident commander locations. Compliance with these signs must be ensured.
is always on the premises even when a reduced number - All persons assigned to perform work on the steam tur-
of employees is on duty (e.g. weekends). bine shall familiarize themselves with all the pertinent op-
- Regularly perform emergency response drills involving all erating, work and maintenance procedures and particu-
power plant employees. larly with the dedicated safety sections in the documen-
- The operator/user shall also ensure that all the equipment tation prior to commencing work. This particularly applies
required for first aid measures, particularly annunciation to personnel such as maintenance personnel who do not
systems, first aid rooms, first aid material and equipment work on the steam turbine on a regular basis.
for transporting ill or injured personnel are available and - The operator / user shall be responsible for ensuring
ready for use. This equipment shall comply with general- compliance with all safety instructions and warnings at
ly-recognized technical and medical standards as well as the steam turbine and in the technical documentation.
standards of hygiene. Used (dressing) material and med- - Any irregularities during operation must be reported di-
ical supplies shall be replaced as soon as possible. rectly to the supervisor and investigated, and the steam
- First aid equipment shall be provided with clear and per- turbine shut down immediately, if necessary.
manent identification, and information shall be posted on - A supervisor must be designated prior to beginning work
the location of first aid material, rescue equipment and on the steam turbine. The supervisor is responsible for
equipment for transporting ill or injured employees. coordination and supervision of the work. The supervisor
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
- Following an accident, first aid measures shall be imple- must ensure full compliance with all safety aspects rele-
mented immediately and, arrangements for professional vant to personnel and equipment, including auxiliary sys-
medical care taken, if required. tems. This includes ensuring that the appropriate protec-
- Where the customer is informed of safety-related tive apparel and equipment are worn.
Copyright Siemens AG 2007 - All Rights Reserved
changes in the form of Basic Solutions (BSol), Special - The supervisor must also ensure that prior to the start of
Solutions (SSol) and Field Revision Requests (FRR), work on all systems containing or carrying hazardous
these must be implemented within the timeframe given media, these systems are sufficiently washed/purged/in-
of a utility model or design, are reserved.
therein. This applies both to technical changes as well as erted and that lockout/tagout procedures are followed,
to changes in the documentation. when applicable. Also note that special safety measures
- If the documentation attached to the BSol, SSol or FRR may in some cases be required for washing/purging/in-
contains safety-related changes, the operator must im- erting.
plement measures to ensure that no injury or damage can - If work is being performed on several systems or at sev-
occur through the use of the outdated documentation. eral locations of one system at the same time, the work
This can, for example, take the form of red entries in all must be coordinated so as to prevent work on one system
existing copies of the manuals and the insertion of com- from creating a hazard to other systems or those working
ments in the electronic versions. Safety-related changes on these systems.
are in this context taken to mean changes designed to - The buddy system shall always be used when work in
avoid personnel injury or material damage. hazardous areas so that rescue measures can be
- It is the operator's/user's responsibility to ensure that all promptly initiated if necessary. This also applies when
hazardous materials on site are properly labeled and working in confined spaces.
safely stored and handled. It must also be ensured that - Ensure that emergency exits, escape routes, fire extin-
all persons who come into contact with these materials guishers and emergency switches are present in suffi-
are informed as to the associated dangers as well as the cient number, are appropriately marked and are fully-
Class: FOR INTERNAL USE ONLY
appropriate protective/safety and first aid measures. functional and accessible at all times.
- Comply with all the applicable laws, regulations and stip- - Ensure that all safety, protective and rescue equipment
ulations when storing, transporting and disposing of op- is fully functional at all times. Perform regular inspections
erating media, cleaning agents, etc. to confirm this. Protective equipment also includes
- Hazardous areas shall be clearly marked as such and grounding connections.
access restricted or prevented as appropriate. Additional - Equipment designed for use as climbing aids (e.g. lad-
probitive signs shall be posted as appropriate (e.g. No ders) and which is in proper working order shall be used
Smoking, No Open Flame, ...). whenever work is performed at a great height. This may
require erecting scaffolds or work platforms.
- All work areas and transport routes higher than one meter Cellular phones, two-way radios and CD play-
above ground level or which border on hazardous areas, ers prohibited!
must be provided with permanent barriers to prevent per-
To prevent possible interference with the steam
sonnel from falling or from accessing hazardous areas.
turbine control system, the use of two-way radios,
- All openings, pits, shafts, ducts and other recesses or cellular phones, and CD players is prohibited in
holes which represent a danger to personnel, all recep- the vicinity of steam turbine control equipment.
tacles with hot, caustic or poisonous substances as well
as any roofs, covers and rooflights/skylights which cannot Personnel
be walked on, in the work or transport area must be pro-
vided with permanent barriers to prevent personnel falling With regard to personnel working on the steam turbine,
in or falling through. compliance must be ensured with the following:
- Work areas or transport routes shall be protected against The following measures reduce or eliminate
falling objects if there is a risk of personal injury. the risk of injury:
- Work on two levels, one immediately above the other,
shall only be permissible if the work areas and transport
routes below are properly protected against any objects - It is the responsibility of the operator / user to ensure that
and masses which may fall down, fall over, slide or roll off only authorized personnel, who are reliable and have
the area above. been duly trained and instructed, work on the steam tur-
- Protective apparel and equipment must be used where bine and that this work is performed under compliance
with all the applicable laws, regulations, specifications,
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
on completion. In addition, checks of whether all requisite products generally recognized as safe and environmen-
safety measures have been taken must be made/called tally compatible whenever possible. Refer to the manu-
for prior to performance of work. facturer's documentation in the case of outside vendor
- New hazards (e.g. leaks) detected by personnel must be parts.
immediately reported to the responsible party.
- Any employee who discovers while performing work that
Safety Notices Regarding Certain Phases
associated hazards are greater than previously assumed in the Service Life of the Steam Turbine
(e.g. loss of forced ventilation) shall discontinue this work
and immediately consult the responsible party. Transporting and Lifting Loads
The following safety notices pertain to the safe transport
Modifications to Steam Turbine of loads (these notices apply to all transports over the service
life of the steam turbine, i.e. also to the handling of spare
Do not carry out any modifications to the steam turbine.
parts, etc.):
Any changes to the steam turbine must be approved by Sie-
mens AG. Such modifications can result in the warranty be- Warning!
coming invalid or can render other contractual stipulations in-
valid. Risk of injury: Do not walk or stand under suspen-
ded loads. Falling loads can cause personal injury
Warning! or death.
Risk of injury or equipment damage: Unauthor- The following measures reduce or eliminate
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
ized modifications can adversely affect the (op- the risk of injury:
erational) safety of the steam turbine and result in
injury or equipment damage.
- Only use specified load attachment points. Only use suit-
Copyright Siemens AG 2007 - All Rights Reserved
slings.
the protective sheeting, etc. is often damaged and mois-
ture can ingress the crate. In this case either the entire - Loads shall not be attached by placing the hoisting rope
crate / crate contents shall be stored in a protected envi- or chain in a loop around the load.
ronment or the original condition of the protection must - It is not permissible for provisional equipment to be used
be re-established by competent personnel. for attaching loads, as this can lead to severe injury or
- Remove preservation agents from spare parts prior to even death.
their installation using a suitable cleaning agent (e.g. a - All prescribed safety distances shall be complied with
room temperature degreaser or similar cleaning agent). when using hoisting equipment and barriers shall be erec-
Which cleaning agent is suitable depends on the type of ted where necessary.
preservation and on the component to be cleaned. Use
- Only use qualified and experienced staff for attaching Check all items (including spare parts) for signs of
loads or instructing crane operators. The person issuing transport damage upon receipt. Immediately re-
instructions must remain within operator's sight or in voice port such damage to the transport company in
contact with him. writing.
- Prior to transporting heavy components within buildings, Meticulously check individual parts for signs of
ensure that the building has a sufficient load-bearing ca- damage. Report any damage to the manufacturer
pacity over the entire transport path and at the installation in writing.
or storage site.
Where crates are opened for checking the com-
- Always use lifting gear to lift/transport heavy items. ponents, the protective sheeting, etc. is often
- Secure items being handled to reliably prevent rolling, damaged and moisture can ingress the crate. To
sliding and dropping. prevent damage to parts, either the entire crate /
crate contents shall be stored in a protected en-
- Always take appropriate safety precautions when trans-
vironment or the original condition of the protec-
porting hazardous materials.
tion must be re-established by competent person-
- Cranes and forklifts shall only be used by personnel who nel.
can provide the requisite qualifications (e.g. crane and
forklift operator permits). Erection and Commissioning
- Load-handling equipment shall not be used to transport The safety instructions in the erection and commissioning
personnel. manuals apply during erection and commissioning:
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
Warning!
- Apply supports and attach slings to turbine components
Risk to life. Personnel with pacemakers are not
at the intended points only.
permitted to enter the turbine building during op-
- Do not remove packaging materials and protective wrap- eration as an operating generator generates elec-
ping during transport. If necessary, provide items to be tromagnetic fields in its vicinity which can ad-
transported with suitable packaging and wrapping mate- versely affect the proper functioning of the pace-
rials. maker.
- If protective transit fixtures are removed for checking in-
dividual parts, they shall be re-attached and then not re- The following measures reduce or eliminate
moved until immediately prior to final installation of the the risk of injury:
items.
- Prevent turbine rotor from rope-induced damage by using
- High temperatures within noise abatement shrouds and
suitable cushions at load attachment points.
other enclosures during plant operation and after shut-
Class: FOR INTERNAL USE ONLY
- It is forbidden for personnel to be on the outer casings - In order to avoid damage to the steam turbine and its
under any operating mode. The party responsible for the auxiliary systems, interfacing systems shall be operated
power plant shall implement the necessary organizational such as to ensure compliance with the set conditions and
and/or technical measures to ensure that this is observed. limit values (e.g. as specified in the system diagrams and
- If the presence of personnel is necessary in the vicinity of component diagrams) at the interfaces with the steam
the rupture diaphragms, the party responsible for the turbine and its auxiliary systems.
power plant shall implement the requisite additional safe- - Observe all alarm annunciations and take immediate re-
ty measures which must be in compliance with the work medial action to rectify their cause (see Section on Com-
permit procedure valid at the plant. ments on Annunciations in the Operating Documenta-
- The steam turbine is operated from the control room. Re- tion), if necessary the turbine shall be tripped immediate-
maining in the immediate vicinity of the steam turbine ly.
when it is running is only permitted in the case of inspec-
tion and maintenance work which requires steam turbine Maintenance and Inspection
operation. The following safety instructions apply during steam tur-
- Check the steam turbine regularly for any visible damage bine maintenance and inspection:
or defects. Any changes (including changes in operating
Danger!
behavior) must be immediately reported to the depart-
ment and/or person(s) responsible. The steam turbine Risk of burns caused by hot surfaces. Steam tur-
must be shut down immediately, if necessary. Do not re- bine components may remain hot even after
start the steam turbine until the faults have been elimina- coastdown and cause burns. Allow sufficient time
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
ted. Contact Siemens Power Generation in case of doubt. for components to cool down.
- Only use lubricants specified by the manufacturer.
Isolate, lockout and tagout before commenc-
- Carry out and record requisite checks during steam tur- ing work!
Copyright Siemens AG 2007 - All Rights Reserved
bine operation.
Prior to commencing work on the steam turbine or
- Ensure compliance with legal codes on noise abatement. steam turbine auxiliary systems, the respective
of a utility model or design, are reserved.
- Entering noise abatement shrouds and other enclosures segment must be isolated (deenergize, depressu-
during operation of the steam turbine is forbidden, unless rize, inert, etc.), locked out and tagged out. Isola-
necessary for inspection or maintenance work. Such tion, lockout and tagout procedures shall be fol-
areas shall be locked to prevent unauthorized access. lowed where applicable.
- Building and equipment areas protected by CO2 fire ex-
The following measures reduce or eliminate
tinguishing systems shall only be entered if absolutely the risk of electric shock:
necessary when such systems have been activated. After
a CO2 fire extinguishing system has been triggered there
is a danger that persons in such areas may lose con- - Only qualified electricians shall perform work on electrical
sciousness or otherwise sustain injury. Prior to starting systems and equipment.
work in areas protected by chemical or CO2 fire extin-
- Before work is performed near the capacitors, these items
guishing systems a second person shall be notified and
must be discharged by qualified electricians.
posted outside the hazard area to immediately initiate
rescue measures if they become necessary. Personnel The following measures reduce or eliminate
shall only remain in such areas for as short a time as the risk of injury:
possible and shall leave the area immediately after the
completion of work.
Class: FOR INTERNAL USE ONLY
- Before commencing any work, completely shut down the - Tools and equipment for inspection and major inspection
steam turbine (disconnect the power supply as well) and may only be used by Siemens personnel or under the su-
secure it against unauthorized or inadvertent restart. Ex- pervision of a Siemens supervisor.
ceptions are only permissible if the work requires the op- - Only use tools and devices for their intended purpose.
eration of a (sub)system. In this case, particular care is Observe load limits. Observe the dedicated instructions
required to prevent accidents and equipment damage. for use, as well as the instructions for the task in hand.
- Do not start up steam turbine if work is performed directly - The use of damaged tools and equipment is not permitted
on the steam turbine or in its immediate vicinity. It must - these shall be repaired immediately or scrapped.
be ensured that no personnel are in areas where there
could be a risk of injury during startup. - No modifications of any kind shall be made to tools and
equipment, which are not in line with their stipulated use.
- Ensure that steam turbine has come to complete stand- It is forbidden to tamper with all pressurized hoses, con-
still before starting any work on the turbine. nections and other accessories.
- Avoid removing protective devices under all circumstan- - Flame equipment (e.g. gas heating equipment for joint
ces. Their removal is only allowable if it is absolutely es- stud bolts) shall only be operated by personnel who have
sential to allow performance of work and if it does not received special instruction in its operation.
pose any risk to personnel. Any protective devices re-
moved shall be replaced immediately upon completion of - Protective goggles and protective thermal gloves must be
work and shall be checked for proper functioning. worn when using flame equipment.
Hazardous fluids. Before carrying out work on pressur- - Wear appropriate protective gear when working with sol-
ized systems (pneumatic, hydraulic, etc.), shut down sys- vents, products containing solvents or other hazardous
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
tems and depressurize relevant sections. Systems may substances. Observe the manufacturer's safety data
contain trapped pressure. Open systems carefully. sheets as well as all locally-applicable laws, codes and
- High temperatures within noise abatement shrouds and regulations. Use products generally recognized as safe
other enclosures during plant operation and after shut- whenever possible. In addition to occupational safety and
Copyright Siemens AG 2007 - All Rights Reserved
down can cause heat-related illnesses and injuries. health, environmental protection must also be ensured.
- Under no circumstances shall personnel be allowed to - Grinding tools shall only be installed by reliable personnel
of a utility model or design, are reserved.
step on the rupture diaphragms covering the discharge familiar with the procedure (including the test run). Grind-
openings on the LP outer casing of the steam turbine or ing tools shall be subjected to a ring test before mounting.
condenser (Risk of suffocation due to vacuum and risk of After mounting, the grinding tool shall be subjected to a
injury). five minutes test run.
- It is forbidden for personnel to be on the outer casings - The maximum circumferential speed of grinding tools
under any operating mode. The party responsible for the shall be selected so as to provide three-fold safety
power plant shall implement the necessary organizational against breakage.
and/or technical measures to ensure that this is observed. - Only suitable and secured tools shall be used for correct-
- If the presence of personnel is necessary in the vicinity of ing out-of-roundness of grinding tools.
the rupture diaphragms, the party responsible for the - Dust containing Ni, Cr or Co, either in compounds or in
power plant shall implement the requisite additional safe- elemental form, can cause cancer. An approved industrial
ty measures which must be in compliance with the work vacuum must be used to extract the dust when grinding
permit procedure valid at the plant. materials containing Ni, Cr or Co. Respirators (class P2
- When removing safety equipment, ensure that this is re- or P3 particle-filtering half facepiece type) must be worn
placed immediately after completing the work and if dust extraction is not possible. Eating, drinking and
checked for proper functioning. smoking while grinding is prohibited. Avoid contact with
Class: FOR INTERNAL USE ONLY
- Before commencing with steam turbine restart ensure - The liquid level of liquid flashback arresters for welding
that personnel is not exposed to any hazards during the work must be checked daily before starting work and after
startup procedure. any flashbacks and must be topped up as necessary.
- If any work (temporarily) blocks traffic routes, appropriate - Never look into the arc or flame of welding equipment
signs and barricades shall be put up to alert personnel. without the appropriate protective equipment (face shield,
- Entering noise abatement shrouds and other enclosures goggles).
during operation of the steam turbine is forbidden, unless - All equipment coming into contact with oxygen must be
necessary for inspection or maintenance work. Such kept free of oil and grease and shall be marked accord-
areas shall be locked to prevent unauthorized access. ingly.
- Building and equipment areas protected by CO2 fire ex- - If the risk of fire cannot be completely ruled out, a fire-
tinguishing systems shall only be entered if absolutely fighting team with the appropriate fire-extinguishing
necessary when such systems have been activated. After equipment shall be charged with monitoring the areas at
a CO2 fire extinguishing system has been triggered there risk and their surroundings. The area at risk and its sur-
is a danger that persons in such areas may lose con- roundings must be checked repeatedly during and after
sciousness or otherwise sustain injury. Prior to starting welding.
work in areas protected by chemical or CO2 fire extin- - It is not permissible to clean clothing using oxygen - this
guishing systems a second person shall be notified and poses a risk to life.
posted outside the hazard area to immediately initiate
rescue measures if they become necessary. Personnel The following measures reduce or eliminate
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
shall only remain in such areas for as short a time as the risk of equipment damage:
possible and shall leave the area immediately after the
completion of work.
- It is recommended that Siemens AG engineering person-
- Only use suitable climbing aids. It is forbidden to use pip-
nel participate in outage inspection and repair work.
Copyright Siemens AG 2007 - All Rights Reserved
can involve air extraction, forced ventilation, venting or shall be made to ensure that all tools, unused and defec-
other suitable method. This also particularly when weld- tive parts have been removed from the work area.
ing in confined spaces.
- Ensure that any tools or any other foreign materials have
- Pressure reducing valves and hoses for welding equip- been removed from the steam turbine before commenc-
ment must be clearly allocatable to the type of gas used ing with the steam turbine startup procedure.
by the corresponding identification marking and appro-
- Ensure compliance with the maintenance and inspection
priate connections.
intervals and the scope of work set forth in the operating
instructions.
- Welding on the steam turbine may only be performed if The following measures reduce or eliminate
approved by Siemens Power Generation. Compliance the risk of injury:
with the applicable welding procedures must be ensured.
- If system sections are opened to perform work, cover
these openings immediately. Covers used for this pur- - Before commencing any work, completely shut down the
pose must be sufficiently close fitting and strong to relia- steam turbine (disconnect the power supply as well) and
bly prevent the ingress of foreign objects. secure it against unauthorized or inadvertent restart in
line with the corresponding instructions and procedures.
- Locking elements and seals are generally disposable (i.e.
Wait until the steam turbine has come to a complete
the locking or sealing function cannot be guaranteed if
standstill. Do not remove safety devices before this time.
reused). This applies in particular to locking elements
which deform plastically (e.g. lock washers and locking - Avoid removing protective devices under all circumstan-
strips for compressor and turbine blades) and to soft iron ces. Their removal is only allowable if it is absolutely es-
seals (e.g. manhole seals). Locking elements/seals must sential to allow performance of work and if it does not
be replaced after use with new ones. Used locking ele- pose any risk to personnel. Any protective devices re-
ments and seals must be accounted for and disposed of moved shall be replaced immediately upon completion of
immediately to prevent their reuse. work and shall be checked for proper functioning.
- Remove preservation agents from spare parts prior to - Observe turbine coastdown time. Failure to do so could
their installation using a suitable cleaning agent (e.g. a result in injury from rotating parts.
room temperature degreaser or similar cleaning agent).
The following measures reduce or eliminate
Which cleaning agent is suitable depends on the type of
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
parts. tionary, hot rotor. Ensure that auxiliary bearing oil pumps
continue operation for a number of hours.
- Only those lubricants, sealants and media shall be used
- Take appropriate measures to protect and preserve tur-
of a utility model or design, are reserved.
shall be tested each working day by depressing the test cinity of the steam turbine.
button. Before checking the ground fault circuit interrupt-
ers it must be ensured that all connected loads have been Steam turbines produce noise levels of up to 90 dB(A). In
switched off. the long term such noise levels may result in damage to hear-
Copyright Siemens AG 2007 - All Rights Reserved
Warning!
Caution!
Risk to life. Personnel with pacemakers are not
permitted to enter the turbine building during op- Health hazard: Insulation products used by Sie-
eration as an operating generator generates elec- mens contains a class of man-made fibers called
tromagnetic fields in its vicinity which can ad- synthetic vitreous fibers (SVF). This class of man-
versely affect the proper functioning of the pace- made fibers is comprised of two distinct groups of
maker. materials; glass, rock or slag fiber or wool and re-
fractory ceramic fibers. Hygiene standards for this
Isolate, lockout and tagout before commenc- class of materials vary from country to country. It
ing work! is the operator's / user's responsibility to verify
regulatory requirements and to comply with the
Isolate, lock out and tag out all equipment on
control standards in your country. SVF containing
which maintenance or repair work is to be per-
insulating materials can cause irritation to the
formed Check to ensure that isolated components
skin, eyes, mucous membranes and the respira-
are de-energized, then ground them and isolate
tory system. Adequate personal protective equip-
any adjacent components which are still live.
ment should be used to reduce direct contact with
Where applicable, follow prescribed isolation,
the material. Please refer to the insulation manu-
Class: FOR INTERNAL USE ONLY
Unit 10
File Ident: MA.TP2.01
File: MA 1-4 General / Descriptions
Chapter 3
Technical Data
Title Identification No. Date
Table of Contents Chapter 3 1.1.1-02003-12565 0212E
Unit 10
File Ident: MA.TP2.01
File: MA 1-4 General / Descriptions
Rating
Maximum continuous rating (MCR) 800 MW
Maximum capability 840 MW
Maximum overload capability 918 MW
Definitions according to IEC No. 45;1st edition 91-05 paragraph 3.5:
SIEMENS
Copyright Siemens AG 2012 - All Rights Reserved
STEAM TURBINE
Turbine, Types
SST5-6000
Four-casing condensing turbine with reheat and heat extraction
Moments of Inertia
Rotor of the first turbine section 10MAA50 HB001 1206 kg m2
Weights
HP turbine, completely assembled with inlet pipes (without valves) 10MAA50 122.0 Mg
IP Tturbine, completely assembled 10MAB50 210.0 Mg
IP turbine, top half outer casing 10MAA50 41.4 Mg
IP turbine, top half inner casing with blading 10MAA50 38.0 Mg
LP turbine, completely assembled 10MAC10/20 215.0 Mg
LP turbine, top half outer casing 10MAC10/20 31.0 Mg
LP turbine, top half inner casing with diffusers 10MAC10/20 34.2 Mg
LP turbine, top half stationary blade carrier - Generator End, stages 1 to 5 10MAC10/20 4.0 Mg
LP turbine, top half stationary blade ring - Generator End, stages 6 to 7 10MAC10/20 4.0 Mg
Class: FOR INTERNAL USE ONLY
LP turbine, top half stationary blade carrier - Turbine End, stages 1 to 5 10MAC10/20 4.0 Mg
LP turbine, top half stationary blade ring - Turbine End, stages 6 to 7 10MAC10/20 4.0 Mg
HP turbine rotor complete with blading 10MAA50 HB001 17.0 Mg
IP turbine rotor complete with blading 10MAB50 HB001 39.5 Mg
LP turbine rotor complete with blading 10MAC10/20 HB001 75.0 Mg
All weights calculated with 10 % safety factor. Use only slings that provide proper safety protection.
Valves, Types
Number Valve KKS Type
10MAA11 AA051
HPV 250-V32-C
10MAA21 AA051
2 Main steam stop and control valves
10MAA12 AA151
HPV 200-V32-C
10MAA22 AA151
10MAB11 AA051
IPV 560-V22
10MAB21 AA051
2 Reheat steam stop and control valves
10MAB12 AA151
IPV 500-V22
10MAB22 AA151
10MAN52 AA161
2 IP Bypass steam stop and control valves DN 500
10MAN55 AA161
1 Overload valve 10MAA14 AA151 HPV 125-V32
Weights
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
10MAA21 AA051
10MAA22 AA151
10MAB11 AA051
of a utility model or design, are reserved.
Reheat steam stop and control valves, complete, without 10MAB12 AA151 each
bend and pipe sections 10MAB21 AA051 50.2 Mg
10MAB22 AA151
Overload valve, complete, without bend and pipe sections 10MAA14 AA151 4.25 Mg
IP Bypass steam stop valve control valve, complete, with- 10MAN52 AA161 each
out bend and pipe sections 10MAN55 AA161 5.35 Mg
Class: FOR INTERNAL USE ONLY
Auxiliary equipment in cold reheat, cross over piping and extractions, types
Cold reheat 1 Cold reheat Non-Return Valve with Actuator, DN 800 10LBC10 AA051 801-254
1 A3 Extraction LP Turbine 2 Extraction Non Return Valve with
Extraction 1 10LBS30 AA051 803-333RL
Actuator, DN 600
1 A3 Extraction LP Turbine 2 Extraction Non Return Valve with-
Extraction 1 10LBS30 AA052
out Actuator, DN 600
1 A3 Extraction LP Turbine 1 Extraction Non Return Valve with
Extraction 2 10LBS31 AA051 803-333RL
Actuator, DN 600
1 A3 Extraction LP Turbine 1 Extraction Non Return Valve with-
Extraction 2 10LBS31 AA052
out Actuator, DN 600
1 A4 Extraction IP Turbine Extraction Non Return Valve with Ac-
Extraction 3 10LBS40 AA051 803-333RL
tuator, DN 500
1 A4 Extraction IP Turbine Extraction Non Return Valve without
Extraction 3 10LBS40 AA052 803-331L
Actuator, DN 500
1 A5 Extraction IP Turbine Extraction Non Return Valve with Ac-
Extraction 4 10LBS50 AA051 803-333RL
tuator, DN 600
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
tuator, DN 300
1 A6 Extraction IP Turbine Extraction Non Return Valve without
Extraction 5 10LBQ60 AA052 803-331L
of a utility model or design, are reserved.
Actuator, DN 300
1 A8 Extraction HP Turbine Extraction Non Return Valve with
Extraction 6 10LBQ80 AA051 803-333RL
Actuator, DN 200
1 A8 Extraction HP Turbine Extraction Non Return Valve without
Extraction 6 10LBQ80 AA052 803-331L
Actuator, DN 200
All weights calculated with 10% safety factor. Use only slings that provide proper safety protection.
Class: FOR INTERNAL USE ONLY
Steam Pressures
Copyright Siemens AG 2012 - All Rights Reserved
1) Long-term operation: Upper limit, permissible but the annual average value must not exceed the nominal value.
2) Short-term operation: Operation at maximum short term conditions is only allowed up to 15 minutes per instance,
provided the total time does not exceed 80 hours during any 12 month operating period.
3) Set safety valves such as to ensure that this value is not exceeded during short-term operation.
Energy Sector
Technical Data
Steam Turbines
Siemens AG
Pressure in seal steam header
Seal Steam Supply System 10MAW
MA &MDA019
Design Data
Supply System
0.035
barg
Steam Mass Flows, Steam Pressures, Seal Steam
0212E
1.1.3-00500-12565 / 2-2
Steam Turbines Design Data
Technical Data Estimated Oil Requirement of Bearings, Lift Oil Pump
Cut-In and Out Speeds
Unit 10
File Ident: MA.TP2.01
File: MA 1-4 General / Descriptions
Steam Temperatures
Steam Admission
Nominal Long-term but 400 h per year 80 h per year but
subject to annual no more than 15
average min at a time
Main steam 565 569 575 589 C
at inlet to reheat valve
593 597 603 617 C
of IP turbine
Steam Exhaust
Nominal Long-term 1) Short-term 80 h Exceptional condi-
per year but no tions at no-load
more than 15 min operation
at a time
Extraction 8 381 420 469 - C
HP exhaust 347 393 455 510 2) C
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
Extraction 2 86 90 124 - C
Extraction 1 68 180 230 - C
LP 1 exhaust 45 90 110 - C
LP 2exhaust 40 90 110 - C
1) Long-term value: Upper limit, permissible without time restriction.
2) Only valid after trip-out at full load operation with high reheat pressure.
It is expected that the turbine is reloaded immediately or the unit is unloaded to minimum boiler load.
At minimum boiler load no load operations is also permissible at rated main steam conditions without time restriction.
Limit values
Alarm at Trip to be initi-
ated at 4)
HP steam temperature, exhaust end 10MAA50CT021/22/23 500 1) 510 1) C
+ 30 + 55
Turning gear operation K
- 45 - 55
of a utility model or design, are reserved.
+ 30 + 55
Startup to speed K
- 45 - 55
+ 30 + 45
Power operation K
- 30 - 45
- 30 - 45
The steam temperatures in the hottest pipes must not exceed the limits given above.
shafts.
Energy Sector
Technical Data
Steam Turbines
Siemens AG
Shaft Temperatures
MA&MDA019
Limit- and Setting Values
Steam-, Casing-, Shaft-Temperatures
Fracture toughness of materials decreases with temperature. For start-up, a minimum temperature of 20 C is required for all
0212E
1.1.3-20400-12565 / 3-3
Steam Turbines Limit- and Setting Values
Technical Data Limit Curves / Main Steam Stop Valve
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
= i - m
i = temperature of the inner layer 10MAA11 CT021A
= i - m
i = temperature of the inner layer 10MAA12 CT021A
Energy Sector
Technical Data
m
i
Steam Turbines
Siemens AG
=
=
=
MAA &MDA029
10MAA50 CT032A
10MAA50 CT031A
Limit Curves / HP Casing
Limit-and Setting Values
0212E
1.1.3-20520-12565 / 1-1
Steam Turbines Limit- and Setting Values
Technical Data Limit Curves / HP Shaft
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
= 0 - m
0 = inner layer temperature of the inner casing is equivalent to 10MAY01 EP154.XQ10
surface temperature of the shaft
m = mean temperature of the shaft (calculated) 10MAY01 EP154.XQ01
For axis temperatures below 100 C the permissible temperature difference is the minimum value between as
function of the mean temperature (right diagram) and as function of the axis temperature (left diagram).
Class: FOR INTERNAL USE ONLY
= 0 - m
0 = inner layer temperature of the inner casing is equivalent to 10MAY01 EP155.XQ10
surface temperature of the shaft
m = mean temperature of the shaft (calculated) 10MAY01 EP155.XQ01
For axis temperatures below 100 C the permissible temperature difference is the minimum value between as
function of the mean temperature (right diagram) and as function of the axis temperature (left diagram).
Class: FOR INTERNAL USE ONLY
During motor operation, the generator keeps the turbine operating at rated speed since the steam supply to the turbine is
interrupted.
In this operation mode, the windage power of the blading causes certain turbine components to heat up.
Copyright Siemens AG 2012 - All Rights Reserved
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY
Bearing Temperatures
Alarm at Unit shut down at
Limit radial Bearing 1 10MAD11 HD001 90 C 130 C
Limit axial Bearing 2 10MAD12 HD001 100 C 130 C
Limit radial Bearing 2 10MAD12 HD001 110 C 130 C
Limit radial Bearing 3 10MAD13 HD001 110 C 130 C
Limit radial Bearing 4 10MAD14 HD001 110 C 130 C
Limit radial Bearing 5 10MAD15 HD001 110 C 130 C
Vibration
Absolute bearing casing vibration Relative shaft vibration
Standard alarm setting
9.3 mm/s 165 m (pk-pk)
Warning HIGH
Trip limit
11.8 mm/s 240 m (pk-pk)
Turbine Trip High
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
In case of loss of seal steam the turbine can be operated temporarily without a shaft seal steam supply.
This is allowable for a limited time and depends on the mean integral shaft temperature.
See Diagram:
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
Caution
Before air ingress make sure that an inhomogeneous temperature distribution has not already been caused by
cold seal steam.
Adherence to this curve is required during startup with air ingress to prevent closure of clearances within the
Class: FOR INTERNAL USE ONLY
turbine.
For reasons of corrosion chemistry, a limit of 3 hours should not be exceeded for each individual event.
30 hours maximum may be accumulated over the year.
Note!
The Gland Steam valve shall only open, when the following conditions are fulfilled:
Speed
Rated speed 50 s-1
Unit 10
File Ident: MA.TP2.01
File: MA 1-4 General / Descriptions
Application Column
Measured values and input values and processing thereof, are entered in the column Application using the appropriate
code letters. Generally, several code letters are placed one after the other, with the meaning of the code being a function of the
position of the individual letters within the overal code. Example:
Position of code letter First letter Supplementary letter 1st successive let- 2nd successive letter
ter
Code letter P D I C
Further successive letters may also be added. The definition of all code letters is given in the following table.
The abbreviations given in the column Application are allocated in accordance with DIN 19227, Part 1,
Groups 1 and 2
Code letter Group 1: Measured value or other input variable, Final con- Group 2: Processing
trol element
Definition when used as first Definition when used as Definition when used as succes-
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
A Fault alarm
C Self-control regulation
Copyright Siemens AG 2006 - All Rights Reserved
D Density Difference
I Indication
fault alarm)
P Pressure
Code letter Group 1: Measured value or other input variable, Final con- Group 2: Processing
trol element
Definition when used as first Definition when used as Definition when used as succes-
letter supplementary letter sive letter
Y Arithmetic function
/ Intermediate value
1) may also be used to indicate the limit positions open or closed, or switching status On or Off.
Class: FOR INTERNAL USE ONLY
Technical Data
Steam Turbines
KKS Description Application Measuring Range P&I Diag. Inst. Site Design Arrangement
Group
Start End Unit
10LBA11CP004 MAIN STEAM EMERGENCY STOP VALVE 1 UP- PIRC 0 300 bar 12565-986132 01360000 PA103B
STREAM PRESSURE
10LBA11CP005 MAIN STEAM EMERGENCY STOP VALVE 1 UP- PIRC 0 300 bar 12565-986132 01360000 PA103B
STREAM PRESSURE
10LBA11CT007A MAIN STEAM EMERGENCY STOP VALVE 1 UP- TIRA 0 600 C 12565-986132 01360000 TT301A
STREAM TEMPERATURE
10LBA11CT007B MAIN STEAM EMERGENCY STOP VALVE 1 UP- - 0 600 C 12565-986132 01360000 TT301A
STREAM TEMPERATURE
10LBA11CT401 MAIN STEAM EMERGENCY STOP VALVE 1 UP- TK 0 600 C 01360000 TT301B
STREAM TEMPERATURE
10LBA12CP004 MAIN STEAM EMERGENCY STOP VALVE 2 UP- PIRC 0 300 bar 12565-986132 01360000 PA103B
STREAM PRESSURE
10LBA12CP005 MAIN STEAM EMERGENCY STOP VALVE 2 UP- PIRC 0 300 bar 12565-986132 01360000 PA103B
STREAM PRESSURE
10LBA12CT007A MAIN STEAM EMERGENCY STOP VALVE 2 UP- TIRA 0 600 C 12565-986132 01360000 TT301A
MA &MEC409
STREAM TEMPERATURE
10LBA12CT007B MAIN STEAM EMERGENCY STOP VALVE 2 UP- - 0 600 C 12565-986132 01360000 TT301A
STREAM TEMPERATURE
Technical Data
Steam Turbines
KKS Description Application Measuring Range P&I Diag. Inst. Site Design Arrangement
Group
Start End Unit
10LBB12CT007A INTERCEPT EMERGENCY STOP VALVE 2 UP- TIRA 0 700 C 12565-986132 01360000 TT301A
STREAM TEMPERATURE
10LBB12CT007B INTERCEPT EMERGENCY STOP VALVE 2 UP- - 0 700 C 12565-986132 01360000 TT301A
STREAM TEMPERATURE
10LBB12CT401 INTERCEPT EMERGENCY STOP VALVE 2 UP- TK 0 700 C 01360000 TT301B
STREAM TEMPERATURE
10LBB21CP001 INTERMEDIATE PRESSURE STEAM BYPASS PIRC 0 80 bar 12565-986130 01360000 PA103B
VALVE 1 UPSTREAM PRESSURE
10LBB21CP002 INTERMEDIATE PRESSURE STEAM BYPASS PIRC 0 80 bar 12565-986130 01360000 PA103B
VALVE 1 UPSTREAM PRESSURE
10LBB21CT001A INTERMEDIATE PRESSURE STEAM BYPASS TIRACZ 0 700 C 12565-986130 01360000 TT301A
VALVE 1 UPSTREAM TEMPERATURE
10LBB21CT001B INTERMEDIATE PRESSURE STEAM BYPASS - 0 700 C 12565-986130 01360000 TT301A
VALVE 1 UPSTREAM TEMPERATURE
10LBB21CT002A INTERMEDIATE PRESSURE STEAM BYPASS TIRACZ 0 700 C 12565-986130 01360000 TT301A
MA &MEC409
Technical Data
Steam Turbines
KKS Description Application Measuring Range P&I Diag. Inst. Site Design Arrangement
Group
Start End Unit
10LBB22CT003A INTERMEDIATE PRESSURE STEAM BYPASS TIRACZ 0 700 C 12565-986130 01360000 TT301A
VALVE 2 UPSTREAM TEMPERATURE
10LBB22CT003B INTERMEDIATE PRESSURE STEAM BYPASS - 0 700 C 12565-986130 01360000 TT301A
VALVE 2 UPSTREAM TEMPERATURE
10LBC10CG051B COLD REHEAT NON-RETURN FLAP 1 100% PO- GIR 100 100 % 12565-986132 LBC10AA051 09000100 -
SITION
10LBC10CG051C COLD REHEAT NON-RETURN FLAP 1 0% PO- GIR 0 0 % 12565-986132 LBC10AA051 09000100 -
SITION
10LBC10CG051F COLD REHEAT NON-RETURN FLAP 1 POSI- GIR % 12565-986132 LBC10AA051 09000100 -
TION
10LBC10CP001 COLD REHEAT NON-RETURN FLAP UP- PIRA -1 79 bar 12565-986132 01360000 PA103B
STREAM PRESSURE
10LBC10CP002 COLD REHEAT NON-RETURN FLAP UP- - -1 79 bar 12565-986132 01360000 PA103B
STREAM PRESSURE
10LBC10CP003 COLD REHEAT NON-RETURN FLAP UP- - -1 79 bar 12565-986132 01360000 PA103B
MA &MEC409
STREAM PRESSURE
10LBC10CP401 COLD REHEAT NON-RETURN FLAP UP- PK -1 79 bar 01360000 PA103E
STREAM PRESSURE
Technical Data
Steam Turbines
KKS Description Application Measuring Range P&I Diag. Inst. Site Design Arrangement
Group
Start End Unit
10LBG30CT001A SEAL STEAM SUPPLY VALVE UPSTREAM TEM- TIRAS 0 400 C 12565-984131 01360000 TT301A
PERATURE
10LBG30CT001B SEAL STEAM SUPPLY VALVE UPSTREAM TEM- - 0 400 C 12565-984131 01360000 TT301A
PERATURE
10LBG30CT002A SEAL STEAM SUPPLY VALVE UPSTREAM TEM- TIRAS 0 400 C 12565-984131 01360000 TT301A
PERATURE
10LBG30CT002B SEAL STEAM SUPPLY VALVE UPSTREAM TEM- - 0 400 C 12565-984131 01360000 TT301A
PERATURE
10LBQ60CG051 EXTRACTION 6 NON-RETURN FLAP 1 POSI- GIR 0 100 % 12565-986132 LBQ60AA051 08603100 -
TION
10LBQ60CG052 EXTRACTION 6 NON-RETURN FLAP 2 POSI- GIR 0 100 % 12565-986132 LBQ60AA052 08607100 -
TION
10LBQ60CP001 EXTRACTION 6 PRESSURE PIR 0 160 bar 12565-986132 01360000 PA103B
10LBQ60CP002 EXTRACTION 6 NON-RETURN FLAP DIFFER- PDIRS 0 100 mbar 12565-986132 01360000 PL101B
ENTIAL PRESSURE
MA &MEC409
Index: 55
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description Application Measuring Range P&I Diag. Inst. Site Design Arrangement
Group
Start End Unit
10LBS31CG051 EXTRACTION 3 NON-RETURN FLAP 1 POSI- GIR 0 100 % 12565-986132 LBS31AA051 08303100 -
TION
10LBS31CG052 EXTRACTION 3 NON-RETURN FLAP 2 POSI- GIR 0 100 % 12565-986132 LBS31AA052 08507100 -
TION
10LBS31CP001 EXTRACTION 3 PRESSURE PIR 0 40 bar 12565-986132 01360000 PA103B
10LBS31CP401 EXTRACTION 3 PRESSURE PK 0 40 bar 01360000 PA103E
10LBS31CT001A EXTRACTION 3 TEMPERATURE TIR 0 600 C 12565-986132 01360000 TT301A
10LBS31CT001B EXTRACTION 3 TEMPERATURE - 0 600 C 12565-986132 01360000 TT301A
10LBS31CT401 EXTRACTION 3 TEMPERATURE TK 0 600 C 01360000 TT301B
10LBS32CP001 EXTRACTION 3 PRESSURE PIR 0 40 bar 12565-986132 01360000 PA103B
10LBS32CP401 EXTRACTION 3 PRESSURE PK 0 40 bar 01360000 PA103E
10LBS32CT001A EXTRACTION 3 TEMPERATURE TIR 0 600 C 12565-986132 01360000 TT301A
10LBS32CT001B EXTRACTION 3 TEMPERATURE - 0 600 C 12565-986132 01360000 TT301A
10LBS32CT401 EXTRACTION 3 TEMPERATURE TK 0 600 C 01360000 TT301B
MA &MEC409
10LBS40CG051 EXTRACTION 4 NON-RETURN FLAP 1 POSI- GIR 0 100 % 12565-986132 LBS40AA051 08403100 -
TION
10LBS40CG052 EXTRACTION 4 NON-RETURN FLAP 2 POSI- GIR 0 100 % 12565-986132 LBS40AA052 08407100 -
10LBS50CG052 EXTRACTION 5 NON-RETURN FLAP 2 POSI- GIR 0 100 % 12565-986132 LBS50AA052 08507100 -
TION
10LBS50CP001 EXTRACTION 5 PRESSURE PIR 0 40 bar 12565-986132 01360000 PA103B
10LBS50CP002 EXTRACTION 5 NON-RETURN FLAP DIFFER- PDIRS 0 100 mbar 12565-986132 01360000 PL101B
ENTIAL PRESSURE
10LBS50CP401 EXTRACTION 5 PRESSURE PK 0 15 bar 01360000 PA103E
10LBS50CT001A EXTRACTION 5 TEMPERATURE TIR 0 600 C 12565-986132 01360000 TT301A
0212E
Index: 55
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description Application Measuring Range P&I Diag. Inst. Site Design Arrangement
Group
Start End Unit
10LBS50CT001B EXTRACTION 5 TEMPERATURE - 0 600 C 12565-986132 01360000 TT301A
10LBS50CT401 EXTRACTION 5 TEMPERATURE TK 0 600 C 01360000 TT301B
10MAA11CG051 MAIN STEAM EMERGENCY STOP VALVE 1 PO- GIRAS 0 100 % 12565-931501 MAB11AA051 28200100 -
SITION
10MAA11CL011 MAIN STEAM EMERGENCY STOP VALVE 1 LIRA 100 100 % 12565-931501 MAB11AA051 28700100 -
LEAKAGE PAN LEVEL
10MAA11CP421 MAIN STEAM EMERGENCY STOP VALVE 1 UP- PK 0 350 bar MAA11AA051 01360000 PA103D
STREAM PRESSURE
10MAA11CT021A MAIN STEAM EMERGENCY STOP VALVE 1 TIRASC 0 700 C 12565-931700 MAA11AA051 12450000 -
100% CASING TEMPERATURE
10MAA11CT021B MAIN STEAM EMERGENCY STOP VALVE 1 - 0 700 C 12565-931700 MAA11AA051 12450000 -
100% CASING TEMPERATURE
10MAA11CT022A MAIN STEAM EMERGENCY STOP VALVE 1 50% TIRASC 0 700 C 12565-931700 MAA11AA051 12450000 -
CASING TEMPERATURE
10MAA11CT022B MAIN STEAM EMERGENCY STOP VALVE 1 50% - 0 700 C 12565-931700 MAA11AA051 12450000 -
MA &MEC409
CASING TEMPERATURE
10MAA11CT421 MAIN STEAM EMERGENCY STOP VALVE 1 TK 0 700 C MAA11AA051 01300200 -
STEAM TEMPERATURE
TEMPERATURE
10MAA12CT022A MAIN STEAM CONTROL VALVE 1 50% CASING TIRASC 0 700 C 12565-931700 MAA12AA151 12450000 -
TEMPERATURE
10MAA12CT022B MAIN STEAM CONTROL VALVE 1 50% CASING - 0 700 C 12565-931700 MAA12AA151 12450000 -
TEMPERATURE
10MAA14CG151 MAIN STEAM OVERLOAD VALVE POSITION GIRAS 0 100 % 12565-931585 MAA14AA151 18700100 -
Index: 55
0212E
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description Application Measuring Range P&I Diag. Inst. Site Design Arrangement
Group
Start End Unit
10MAA14CL011 MAIN STEAM OVERLOAD VALVE DRAIN PAN LIRA - 100 % 12565-931585 MAA14AA151 18700100 -
LEVEL
10MAA14CP021 MAIN STEAM OVERLOAD VALVE DOWN- RIC 0 350 bar 12565-931715 01300100 PA103
STREAM PRESSURE
10MAA21CG051 MAIN STEAM EMERGENCY STOP VALVE 2 PO- GIRAS 0 100 % 12565-931502 MAB21AA051 28200200 -
SITION
10MAA21CL011 MAIN STEAM EMERGENCY STOP VALVE 2 LIRA 100 100 % 12565-931502 MAB21AA051 28200200 -
LEAKAGE PAN LEVEL
10MAA21CP421 MAIN STEAM EMERGENCY STOP VALVE 2 UP- PK 0 350 bar MAA21AA051 01360000 PA103D
STREAM PRESSURE
10MAA21CT021A MAIN STEAM EMERGENCY STOP VALVE 2 TIRAS 0 700 C 12565-931700 MAA21AA051 12450000 -
100% CASING TEMPERATURE
10MAA21CT021B MAIN STEAM EMERGENCY STOP VALVE 2 - 0 700 C 12565-931700 MAA21AA051 12450000 -
100% CASING TEMPERATURE
10MAA21CT421 MAIN STEAM EMERGENCY STOP VALVE 2 TK 0 700 C MAA21AA051 01300200 -
MA &MEC409
STEAM TEMPERATURE
10MAA22CG151 MAIN STEAM CONTROL VALVE 2 POSITION GIRAS 0 100 % 12565-931552 MAA22AA151 18700200 -
10MAA22CL011 MAIN STEAM CONTROL VALVE 2 LEAKAGE LIRA 100 100 % 12565-931552 MAA22AA151 18700200 -
STREAM PRESSURE
10MAA50CT011A HIGH PRESSURE TURBINE INLET INNER CAS- TIRACZ 0 700 C 12565-986132 MAA50HA001 12455000 -
ING 100% TEMPERATURE
10MAA50CT011B HIGH PRESSURE TURBINE INLET INNER CAS- - 0 700 C 12565-986132 MAA50HA001 12455000 -
ING 100% TEMPERATURE
10MAA50CT012A HIGH PRESSURE TURBINE INLET INNER CAS- TIRACZ 0 700 C 12565-986132 MAA50HA001 12455000 -
ING 100% TEMPERATURE
0212E
Index: 55
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description Application Measuring Range P&I Diag. Inst. Site Design Arrangement
Group
Start End Unit
10MAA50CT012B HIGH PRESSURE TURBINE INLET INNER CAS- - 0 700 C 12565-986132 MAA50HA001 12455000 -
ING 100% TEMPERATURE
10MAA50CT013A HIGH PRESSURE TURBINE INLET INNER CAS- TIRACZ 0 700 C 12565-986132 MAA50HA001 12455000 -
ING 100% TEMPERATURE
10MAA50CT013B HIGH PRESSURE TURBINE INLET INNER CAS- - 0 700 C 12565-986132 MAA50HA001 12455000 -
ING 100% TEMPERATURE
10MAA50CT015A REAR INNER CASING BLADING STEAM 100% TIRACZ 0 700 C 12565-986132 MAA50HA001 12455000 -
TEMPERATURE
10MAA50CT015B REAR INNER CASING BLADING STEAM 100% - 0 700 C 12565-986132 MAA50HA001 12455000 -
TEMPERATURE
10MAA50CT016A REAR INNER CASING BLADING STEAM 100% TIRACZ 0 700 C 12565-986132 MAA50HA001 12455000 -
TEMPERATURE
10MAA50CT016B REAR INNER CASING BLADING STEAM 100% - 0 700 C 12565-986132 MAA50HA001 12455000 -
TEMPERATURE
10MAA50CT017A REAR INNER CASING BLADING STEAM 100% TIRACZ 0 700 C 12565-986132 MAA50HA001 12455000 -
MA &MEC409
TEMPERATURE
10MAA50CT017B REAR INNER CASING BLADING STEAM 100% - 0 700 C 12565-986132 MAA50HA001 12455000 -
TEMPERATURE
10MAA50CT023B HIGH PRESSURE TURBINE EXHAUST STEAM - 0 600 C 12565-986132 MAA50HA001 12453000 -
TEMPERATURE
10MAA50CT025A HIGH PRESSURE TURBINE BALANCE PISTON TIR 0 700 C 12565-986132 MAA50HA001 12453000 -
GENERATOR SIDE TEMPERATURE
10MAA50CT025B HIGH PRESSURE TURBINE BALANCE PISTON - 0 700 C 12565-986132 MAA50HA001 12453000 -
GENERATOR SIDE TEMPERATURE
Index: 55
0212E
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description Application Measuring Range P&I Diag. Inst. Site Design Arrangement
Group
Start End Unit
10MAA50CT026A HIGH PRESSURE TURBINE BALANCE PISTON TIR 0 700 C 12565-986132 MAA50HA001 12453000 -
GENERATOR SIDE TEMPERATURE
10MAA50CT026B HIGH PRESSURE TURBINE BALANCE PISTON - 0 700 C 12565-986132 MAA50HA001 12453000 -
GENERATOR SIDE TEMPERATURE
10MAA50CT031A HIGH PRESSURE TURBINE INLET GUIDE TIRC 0 700 C 12565-986132 MAA50HA001 12450000 -
VANES OUTER CASING 100% TEMPERATURE
10MAA50CT031B HIGH PRESSURE TURBINE INLET GUIDE - 0 700 C 12565-986132 MAA50HA001 12450000 -
VANES OUTER CASING 100% TEMPERATURE
10MAA50CT032A HIGH PRESSURE TURBINE INLET GUIDE TIRC 0 700 C 12565-986132 MAA50HA001 12450000 -
VANES OUTER CASING 50% TEMPERATURE
10MAA50CT032B HIGH PRESSURE TURBINE INLET GUIDE - 0 700 C 12565-986132 MAA50HA001 12450000 -
VANES OUTER CASING 50% TEMPERATURE
10MAA50CT051A HIGH PRESSURE TURBINE CASING CENTRE TIRA 0 700 C 12565-986132 MAA50HA001 12450000 -
LEFT HAND TOP 50% TEMPERATURE
10MAA50CT051B HIGH PRESSURE TURBINE CASING CENTRE - 0 700 C 12565-986132 MAA50HA001 12450000 -
MA &MEC409
10MAB11CT021B INTERCEPT EMERGENCY STOP VALVE 1 100% - 0 700 C 12565-931710 MAB11AA051 12450000 -
CASING TEMPERATURE
10MAB11CT421 INTERCEPT EMERGENCY STOP VALVE 1 TK 0 700 C MAB11AA051 01300200 -
STEAM TEMPERATURE
10MAB12CG151 INTERCEPT CONTROL VALVE 1 POSITION GIRAS 0 100 % 12565-931581 MAB12AA151 28700100 -
10MAB12CL011 INTERCEPT CONTROL VALVE 1 LEAKAGE PAN LIRA 100 100 % 12565-931581 MAB12AA151 28700100 -
LEVEL
0212E
Index: 55
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description Application Measuring Range P&I Diag. Inst. Site Design Arrangement
Group
Start End Unit
10MAB21CG051 INTERCEPT EMERGENCY STOP VALVE 2 PO- GIRAS 0 100 % 12565-931532 MAB21AA051 28200200 -
SITION
10MAB21CL011 INTERCEPT EMERGENCY STOP VALVE 2 LIRA 100 100 % 12565-931532 MAB21AA051 28200200 -
LEAKAGE PAN LEVEL
10MAB21CP421 INTERCEPT EMERGENCY STOP VALVE 2 UP- PK 0 80 bar MAB21AA051 01360000 PA103D
STREAM PRESSURE
10MAB21CT021A INTERCEPT EMERGENCY STOP VALVE 2 100% TIRAS 0 700 C 12565-931710 MAB21AA051 12450000 -
CASING TEMPERATURE
10MAB21CT021B INTERCEPT EMERGENCY STOP VALVE 2 100% - 0 700 C 12565-931710 MAB21AA051 12450000 -
CASING TEMPERATURE
10MAB21CT421 INTERCEPT EMERGENCY STOP VALVE 2 TK 0 700 C MAB21AA051 01300200 -
STEAM TEMPERATURE
10MAB22CG151 INTERCEPT CONTROL VALVE 2 POSITION GIRAS 0 100 % 12565-931582 MAB22AA151 28700200 -
10MAB22CL011 INTERCEPT CONTROL VALVE 2 LEAKAGE PAN LIRA 100 100 % 12565-931582 MAB22AA151 28700200 -
LEVEL
MA &MEC409
10MAB50CP001 INTERMEDIATE PRESSURE TURBINE BLAD- PIR -1 69 bar 12565-986132 01360000 PA103A
ING UPSTREAM PRESSURE
10MAB50CP401 INTERMEDIATE PRESSURE TURBINE BLAD- PK 0 70 bar 01360000 PA103D
Index: 55
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description Application Measuring Range P&I Diag. Inst. Site Design Arrangement
Group
Start End Unit
10MAB50CT021B INTERMEDIATE PRESSURE TURBINE EX- - 0 600 C 12565-986132 MAB50HA001 22453000 -
HAUST STEAM TEMPERATURE
10MAB50CT022A INTERMEDIATE PRESSURE TURBINE EX- TIRAZ 0 600 C 12565-986132 MAB50HA001 22453000 -
HAUST STEAM TEMPERATURE
10MAB50CT022B INTERMEDIATE PRESSURE TURBINE EX- - 0 600 C 12565-986132 MAB50HA001 22453000 -
HAUST STEAM TEMPERATURE
10MAB50CT023A INTERMEDIATE PRESSURE TURBINE EX- TIRAZ 0 600 C 12565-986132 MAB50HA001 22453000 -
HAUST STEAM TEMPERATURE
10MAB50CT023B INTERMEDIATE PRESSURE TURBINE EX- - 0 600 C 12565-986132 MAB50HA001 22453000 -
HAUST STEAM TEMPERATURE
10MAB50CT041A INTERMEDIATE PRESSURE TURBINE CASING TIRA 0 600 C 12565-986132 MAB50HA001 22450000 -
FRONT LEFT HAND TOP 50% TEMPERATURE
10MAB50CT041B INTERMEDIATE PRESSURE TURBINE CASING - 0 600 C 12565-986132 MAB50HA001 22450000 -
FRONT LEFT HAND TOP 50% TEMPERATURE
10MAB50CT042A INTERMEDIATE PRESSURE TURBINE CASING TIRA 0 600 C 12565-986132 MAB50HA001 22450000 -
MA &MEC409
POSITION
10MAC01CG051C LOW PRESSURE TURBINE EXHAUST STEAM GI 0 0 % 12565-986132 MAC01AA051 98641000 -
COOLING INJECTION CONTROL VALVE 0% PO-
SITION
10MAC01CP501 LOW PRESSURE TURBINE EXHAUST STEAM PI -1 15 bar 12565-986132 01360000 -
COOLING INJECTION 1 UPSTREAM PRES-
SURE
0212E
Index: 55
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description Application Measuring Range P&I Diag. Inst. Site Design Arrangement
Group
Start End Unit
10MAC10CP401 LOW PRESSURE TURBINE 1 UPSTREAM PK -1 9 bar 01360000 PA103D
PRESSURE
10MAC10CP431 LOW PRESSURE TURBINE 1 TURBINE SIDE PK -1 0 bar MAC10HA001 -
EXHAUST STEAM PRESSURE
10MAC10CP432 LOW PRESSURE TURBINE 1 TURBINE SIDE PK -1 0 bar MAC10HA001 -
EXHAUST STEAM PRESSURE
10MAC10CP433 LOW PRESSURE TURBINE 1 TURBINE SIDE PK -1 0 bar MAC10HA001 -
EXHAUST STEAM PRESSURE
10MAC10CP434 LOW PRESSURE TURBINE 1 TURBINE SIDE PK -1 0 bar MAC10HA001 -
EXHAUST STEAM PRESSURE
10MAC10CP435 LOW PRESSURE TURBINE 1 TURBINE SIDE PK -1 0 bar MAC10HA001 -
EXHAUST STEAM PRESSURE
10MAC10CP436 LOW PRESSURE TURBINE 1 TURBINE SIDE PK -1 0 bar MAC10HA001 -
EXHAUST STEAM PRESSURE
10MAC10CP437 LOW PRESSURE TURBINE 1 TURBINE SIDE PK -1 0 bar MAC10HA001 -
MA &MEC409
Technical Data
Steam Turbines
KKS Description Application Measuring Range P&I Diag. Inst. Site Design Arrangement
Group
Start End Unit
10MAC10CT011A LOW PRESSURE TURBINE 1 FINAL STAGE RO- TIRA 0 250 C 12565-986132 MAC10HA001 32453500 -
TATING BLADE ROW UPSTREAM STEAM TEM-
PERATURE
10MAC10CT011B LOW PRESSURE TURBINE 1 FINAL STAGE RO- - 0 250 C 12565-986132 MAC10HA001 32453500 -
TATING BLADE ROW UPSTREAM STEAM TEM-
PERATURE
10MAC10CT012A LOW PRESSURE TURBINE 1 FINAL STAGE RO- - 0 250 C 12565-986132 MAC10HA001 32453500 -
TATING BLADE ROW UPSTREAM STEAM TEM-
PERATURE
10MAC10CT012B LOW PRESSURE TURBINE 1 FINAL STAGE RO- - 0 250 C 12565-986132 MAC10HA001 32453500 -
TATING BLADE ROW UPSTREAM STEAM TEM-
PERATURE
10MAC10CT071A LOW PRESSURE TURBINE 1 TOP EXHAUST TIRAZ 0 150 C 12565-986132 MAC10HA001 32450000 -
STEAM TEMPERATURE
10MAC10CT071B LOW PRESSURE TURBINE 1 TOP EXHAUST - 0 150 C 12565-986132 MAC10HA001 32450000 -
MA &MEC409
STEAM TEMPERATURE
10MAC10CT071C LOW PRESSURE TURBINE 1 TOP EXHAUST - 0 150 C 12565-986132 MAC10HA001 32450000 -
STEAM TEMPERATURE
10MAC10CT073C LOW PRESSURE TURBINE 1 TOP EXHAUST - 0 150 C 12565-986132 MAC10HA001 32450000 -
STEAM TEMPERATURE
10MAC10CT401 LOW PRESSURE TURBINE 1 UPSTREAM TK 0 600 C MAC10BR001 01300300 TT301B
STEAM TEMPERATURE
10MAC11CP001 CROSS OVER PIPE LOW PRESSURE TURBINE PIRAZ 0 10 barabs 12565-986132 MAC11BR001 01360000 PA103H
UPSTREAM PRESSURE
Index: 55
0212E
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description Application Measuring Range P&I Diag. Inst. Site Design Arrangement
Group
Start End Unit
10MAC11CP002 CROSS OVER PIPE LOW PRESSURE TURBINE PIRAZ 0 10 barabs 12565-986132 MAC11BR001 01360000 PA103H
UPSTREAM PRESSURE
10MAC11CP003 CROSS OVER PIPE LOW PRESSURE TURBINE PIRAZ 0 10 barabs 12565-986132 MAC11BR001 01360000 PA103H
UPSTREAM PRESSURE
10MAC11CP401 CROSS OVER PIPE LOW PRESSURE TURBINE PK -1 9 bar 01360000 PA103D
UPSTREAM PRESSURE
10MAC11CT401 CROSS OVER PIPE LOW PRESSURE TURBINE TK 0 600 C MAC11BR001 01300300 TT301B
UPSTREAM STEAM TEMPERATURE
10MAC20CP431 LOW PRESSURE TURBINE 2 TURBINE SIDE PK -1 0 bar MAC20HA001 -
EXHAUST STEAM PRESSURE
10MAC20CP432 LOW PRESSURE TURBINE 2 TURBINE SIDE PK -1 0 bar MAC20HA001 -
EXHAUST STEAM PRESSURE
10MAC20CP433 LOW PRESSURE TURBINE 2 TURBINE SIDE PK -1 0 bar MAC20HA001 -
EXHAUST STEAM PRESSURE
10MAC20CP434 LOW PRESSURE TURBINE 2 TURBINE SIDE PK -1 0 bar MAC20HA001 -
MA &MEC409
Technical Data
Steam Turbines
KKS Description Application Measuring Range P&I Diag. Inst. Site Design Arrangement
Group
Start End Unit
10MAC20CP444 LOW PRESSURE TURBINE 2 GENERATOR PK -1 0 bar MAC20HA001 -
SIDE EXHAUST STEAM PRESSURE
10MAC20CP445 LOW PRESSURE TURBINE 2 GENERATOR PK -1 0 bar MAC20HA001 -
SIDE EXHAUST STEAM PRESSURE
10MAC20CP446 LOW PRESSURE TURBINE 2 GENERATOR PK -1 0 bar MAC20HA001 -
SIDE EXHAUST STEAM PRESSURE
10MAC20CT011A LOW PRESSURE TURBINE 2 FINAL STAGE RO- TIRA 0 250 C 12565-986132 MAC10HA001 42453500 -
TATING BLADE ROW UPSTREAM STEAM TEM-
PERATURE
10MAC20CT011B LOW PRESSURE TURBINE 2 FINAL STAGE RO- - 0 250 C 12565-986132 MAC10HA001 42453500 -
TATING BLADE ROW UPSTREAM STEAM TEM-
PERATURE
10MAC20CT012A LOW PRESSURE TURBINE 2 FINAL STAGE RO- - 0 250 C 12565-986132 MAC10HA001 42453500 -
TATING BLADE ROW UPSTREAM STEAM TEM-
PERATURE
MA &MEC409
10MAC20CT012B LOW PRESSURE TURBINE 2 FINAL STAGE RO- - 0 250 C 12565-986132 MAC10HA001 42453500 -
TATING BLADE ROW UPSTREAM STEAM TEM-
PERATURE
10MAC20CT072C LOW PRESSURE TURBINE 2 TOP EXHAUST - 0 150 C 12565-986132 MAC10HA001 42450000 -
STEAM TEMPERATURE
10MAC20CT073A LOW PRESSURE TURBINE 2 TOP EXHAUST TIRAZ 0 150 C 12565-986132 MAC10HA001 42450000 -
STEAM TEMPERATURE
10MAC20CT073B LOW PRESSURE TURBINE 2 TOP EXHAUST - 0 150 C 12565-986132 MAC10HA001 42450000 -
STEAM TEMPERATURE
Index: 55
0212E
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description Application Measuring Range P&I Diag. Inst. Site Design Arrangement
Group
Start End Unit
10MAC20CT073C LOW PRESSURE TURBINE 2 TOP EXHAUST - 0 150 C 12565-986132 MAC10HA001 42450000 -
STEAM TEMPERATURE
10MAD11CT011A STEAM TURBINE RADIAL BEARING 1 TURBINE TIRAZ 0 150 C 12565-013350 MAD11HD001 11300000 -
SIDE LEFT HAND TOP TEMPERATURE
10MAD11CT011B STEAM TURBINE RADIAL BEARING 1 TURBINE TIRAZ 0 150 C 12565-013350 MAD11HD001 11300000 -
SIDE LEFT HAND TOP TEMPERATURE
10MAD11CT011C STEAM TURBINE RADIAL BEARING 1 TURBINE TIRAZ 0 150 C 12565-013350 MAD11HD001 11300000 -
SIDE LEFT HAND TOP TEMPERATURE
10MAD11CT012A STEAM TURBINE RADIAL BEARING 1 TURBINE TIRAZ 0 150 C 12565-013350 MAD11HD001 11300000 -
SIDE RIGHT HAND TOP TEMPERATURE
10MAD11CT012B STEAM TURBINE RADIAL BEARING 1 TURBINE TIRAZ 0 150 C 12565-013350 MAD11HD001 11300000 -
SIDE RIGHT HAND TOP TEMPERATURE
10MAD11CT012C STEAM TURBINE RADIAL BEARING 1 TURBINE TIRAZ 0 150 C 12565-013350 MAD11HD001 11300000 -
SIDE RIGHT HAND TOP TEMPERATURE
10MAD11CT013A STEAM TURBINE RADIAL BEARING 1 TURBINE TIRAZ 0 150 C 12565-013350 MAD11HD001 11300000 -
MA &MEC409
10MAD11CY022 STEAM TURBINE BEARING 1 CASING ABSO- YIRAZ 0 20 mm/s 12565-013350 MAD11HD001 11300000 -
LUTE VIBRATION
10MAD11CY041 STEAM TURBINE BEARING 1 CASING RELA- YIRA 0 500 m 12565-013350 MAD11HD001 11300000 -
TIVE SHAFT VIBRATION
10MAD11CY042 STEAM TURBINE BEARING 1 CASING RELA- YIRA 0 500 m 12565-013350 MAD11HD001 11300000 -
TIVE SHAFT VIBRATION
Index: 55
0212E
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description Application Measuring Range P&I Diag. Inst. Site Design Arrangement
Group
Start End Unit
10MAD12CT011A STEAM TURBINE RADIAL BEARING 2 TURBINE TIRAZ 0 150 C 12565-013350 MAD12HD001 16300000 -
SIDE LEFT HAND TOP TEMPERATURE
10MAD12CT011B STEAM TURBINE RADIAL BEARING 2 TURBINE TIRAZ 0 150 C 12565-013350 MAD12HD001 16300000 -
SIDE LEFT HAND TOP TEMPERATURE
10MAD12CT011C STEAM TURBINE RADIAL BEARING 2 TURBINE TIRAZ 0 150 C 12565-013350 MAD12HD001 16300000 -
SIDE LEFT HAND TOP TEMPERATURE
10MAD12CT012A STEAM TURBINE RADIAL BEARING 2 TURBINE TIRAZ 0 150 C 12565-013350 MAD12HD001 16300000 -
SIDE RIGHT HAND TOP TEMPERATURE
10MAD12CT012B STEAM TURBINE RADIAL BEARING 2 TURBINE TIRAZ 0 150 C 12565-013350 MAD12HD001 16300000 -
SIDE RIGHT HAND TOP TEMPERATURE
10MAD12CT012C STEAM TURBINE RADIAL BEARING 2 TURBINE TIRAZ 0 150 C 12565-013350 MAD12HD001 16300000 -
SIDE RIGHT HAND TOP TEMPERATURE
10MAD12CT013A STEAM TURBINE RADIAL BEARING 2 TURBINE TIRAZ 0 150 C 12565-013350 MAD12HD001 16300000 -
SIDE LEFT HAND BOTTOM TEMPERATURE
10MAD12CT013B STEAM TURBINE RADIAL BEARING 2 TURBINE TIRAZ 0 150 C 12565-013350 MAD12HD001 16300000 -
MA &MEC409
10MAD12CT031C STEAM TURBINE AXIAL BEARING 2 TURBINE TIRAZ 0 150 C 12565-013350 MAD12HD001 16300000 -
SIDE LEFT HAND TEMPERATURE
10MAD12CT032A STEAM TURBINE AXIAL BEARING 2 TURBINE TIRAZ 0 150 C 12565-013350 MAD12HD001 16300000 -
SIDE RIGHT HAND TEMPERATURE
10MAD12CT032B STEAM TURBINE AXIAL BEARING 2 TURBINE TIRAZ 0 150 C 12565-013350 MAD12HD001 16300000 -
SIDE RIGHT HAND TEMPERATURE
Index: 55
0212E
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description Application Measuring Range P&I Diag. Inst. Site Design Arrangement
Group
Start End Unit
10MAD12CT032C STEAM TURBINE AXIAL BEARING 2 TURBINE TIRAZ 0 150 C 12565-013350 MAD12HD001 16300000 -
SIDE RIGHT HAND TEMPERATURE
10MAD12CT033A STEAM TURBINE AXIAL BEARING 2 GENERA- TIRAZ 0 150 C 12565-013350 MAD12HD001 16300000 -
TOR SIDE LEFT HAND TEMPERATURE
10MAD12CT033B STEAM TURBINE AXIAL BEARING 2 GENERA- TIRAZ 0 150 C 12565-013350 MAD12HD001 16300000 -
TOR SIDE LEFT HAND TEMPERATURE
10MAD12CT033C STEAM TURBINE AXIAL BEARING 2 GENERA- TIRAZ 0 150 C 12565-013350 MAD12HD001 16300000 -
TOR SIDE LEFT HAND TEMPERATURE
10MAD12CT034A STEAM TURBINE AXIAL BEARING 2 GENERA- TIRAZ 0 150 C 12565-013350 MAD12HD001 16300000 -
TOR SIDE RIGHT HAND TEMPERATURE
10MAD12CT034B STEAM TURBINE AXIAL BEARING 2 GENERA- TIRAZ 0 150 C 12565-013350 MAD12HD001 16300000 -
TOR SIDE RIGHT HAND TEMPERATURE
10MAD12CT034C STEAM TURBINE AXIAL BEARING 2 GENERA- TIRAZ 0 150 C 12565-013350 MAD12HD001 16300000 -
TOR SIDE RIGHT HAND TEMPERATURE
10MAD12CY011 STEAM TURBINE AXIAL BEARING 2 SHAFT PO- YIRAZ -1.5 +1.5 mm 12565-013350 MAD12HD001 16300000 -
MA &MEC409
SITION
10MAD12CY012 STEAM TURBINE AXIAL BEARING 2 SHAFT PO- YIRAZ -1.5 +1.5 mm 12565-013350 MAD12HD001 16300000 -
SITION
10MAD12CY045 STEAM TURBINE BEARING 2 KEY PHASE AN- YK 0 360 Deg. 12565-013350 MAD12HD001 16300000 -
GLE
10MAD13CT013A STEAM TURBINE RADIAL BEARING 3 TURBINE TIRAZ 0 150 C 12565-013350 MAD13HD001 26300000 -
SIDE LEFT HAND BOTTOM TEMPERATURE
10MAD13CT013B STEAM TURBINE RADIAL BEARING 3 TURBINE TIRAZ 0 150 C 12565-013350 MAD13HD001 26300000 -
SIDE LEFT HAND BOTTOM TEMPERATURE
Index: 55
0212E
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description Application Measuring Range P&I Diag. Inst. Site Design Arrangement
Group
Start End Unit
10MAD13CT013C STEAM TURBINE RADIAL BEARING 3 TURBINE TIRAZ 0 150 C 12565-013350 MAD13HD001 26300000 -
SIDE LEFT HAND BOTTOM TEMPERATURE
10MAD13CT017A STEAM TURBINE RADIAL BEARING 3 GENER- TIRAZ 0 150 C 12565-013350 MAD13HD001 26300000 -
ATOR SIDE LEFT HAND BOTTOM TEMPERA-
TURE
10MAD13CT017B STEAM TURBINE RADIAL BEARING 3 GENER- TIRAZ 0 150 C 12565-013350 MAD13HD001 26300000 -
ATOR SIDE LEFT HAND BOTTOM TEMPERA-
TURE
10MAD13CT017C STEAM TURBINE RADIAL BEARING 3 GENER- TIRAZ 0 150 C 12565-013350 MAD13HD001 26300000 -
ATOR SIDE LEFT HAND BOTTOM TEMPERA-
TURE
10MAD13CY021 STEAM TURBINE BEARING 3 CASING ABSO- YIRAZ 0 20 mm/s 12565-013350 MAD13HD001 26300000 -
LUTE VIBRATION
10MAD13CY022 STEAM TURBINE BEARING 3 CASING ABSO- YIRAZ 0 20 mm/s 12565-013350 MAD13HD001 26300000 -
LUTE VIBRATION
MA &MEC409
10MAD13CY041 STEAM TURBINE BEARING 3 CASING RELA- YIRA 0 500 m 12565-013350 MAD13HD001 26300000 -
TIVE SHAFT VIBRATION
10MAD13CY042 STEAM TURBINE BEARING 3 CASING RELA- YIRA 0 500 m 12565-013350 MAD13HD001 26300000 -
10MAD14CT017B STEAM TURBINE RADIAL BEARING 4 GENER- TIRAZ 0 150 C 12565-013350 MAD14HD001 36300000 -
ATOR SIDE LEFT HAND BOTTOM TEMPERA-
TURE
10MAD14CT017C STEAM TURBINE RADIAL BEARING 4 GENER- TIRAZ 0 150 C 12565-013350 MAD14HD001 36300000 -
ATOR SIDE LEFT HAND BOTTOM TEMPERA-
TURE
Index: 55
0212E
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description Application Measuring Range P&I Diag. Inst. Site Design Arrangement
Group
Start End Unit
10MAD14CY021 STEAM TURBINE BEARING 4 CASING ABSO- YIRAZ 0 20 mm/s 12565-013350 MAD14HD001 36300000 -
LUTE VIBRATION
10MAD14CY022 STEAM TURBINE BEARING 4 CASING ABSO- YIRAZ 0 20 mm/s 12565-013350 MAD14HD001 36300000 -
LUTE VIBRATION
10MAD14CY041 STEAM TURBINE BEARING 4 CASING RELA- YIRA 0 500 m 12565-013350 MAD14HD001 36300000 -
TIVE SHAFT VIBRATION
10MAD14CY042 STEAM TURBINE BEARING 4 CASING RELA- YIRA 0 500 m 12565-013350 MAD14HD001 36300000 -
TIVE SHAFT VIBRATION
10MAD15CT013A STEAM TURBINE RADIAL BEARING 5 TURBINE TIRAZ 0 150 C 12565-013350 MAD15HD001 46300000 -
SIDE LEFT HAND BOTTOM TEMPERATURE
10MAD15CT013B STEAM TURBINE RADIAL BEARING 5 TURBINE TIRAZ 0 150 C 12565-013350 MAD15HD001 46300000 -
SIDE LEFT HAND BOTTOM TEMPERATURE
10MAD15CT013C STEAM TURBINE RADIAL BEARING 5 TURBINE TIRAZ 0 150 C 12565-013350 MAD15HD001 46300000 -
SIDE LEFT HAND BOTTOM TEMPERATURE
10MAD15CT017A STEAM TURBINE RADIAL BEARING 5 GENER- TIRAZ 0 150 C 12565-013350 MAD15HD001 46300000 -
MA &MEC409
Index: 55
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description Application Measuring Range P&I Diag. Inst. Site Design Arrangement
Group
Start End Unit
10MAG10CG251B CONDENSER 1 VACUUM BREAKER CONTROL GIRA 100 100 % 12565-986131 MAG10AA251 98643000 -
VALVE DOWNSTREAM ISOLATING VALVE
100% POSITION
10MAG10CP002 CONDENSER 1 PRESSURE PIRAZ 0 1.3 barabs 12565-986131 MAG10BR023 01360000 PA104A
10MAG10CP003 CONDENSER 1 PRESSURE PIRAZ 0 1.3 barabs 12565-986131 MAG10BR023 01360000 PA104A
10MAG10CP004 CONDENSER 1 PRESSURE PIRAZ 0 1.3 barabs 12565-986131 MAG10BR023 01360000 PA104A
10MAG10CP511 CONDENSER 1 STAND PIPE 1 WATER INJEC- PI 0 50 bar 12565-986131 MAG10BR003 01360000 -
TION ADJUSTING VALVE DOWNSTREAM
PRESSURE
10MAG10CP512 CONDENSER 1 STAND PIPE 2 WATER INJEC- PI 0 50 bar 12565-986131 MAG10BR005 01360000 -
TION ADJUSTING VALVE DOWNSTREAM
PRESSURE
10MAG20CG051B CONDENSER 2 VACUUM BREAKER CONTROL GV 100 100 % 12565-986131 MAG20AA051 98679000 -
VALVE 100% POSITION
10MAG20CG051C CONDENSER 2 VACUUM BREAKER CONTROL GV 0 0 % 12565-986131 MAG20AA051 98679000 -
MA &MEC409
VALVE 0% POSITION
10MAG20CG251B CONDENSER 2 VACUUM BREAKER CONTROL GIRA 100 100 % 12565-986131 MAG20AA251 98643000 -
VALVE DOWNSTREAM ISOLATING VALVE
Technical Data
Steam Turbines
KKS Description Application Measuring Range P&I Diag. Inst. Site Design Arrangement
Group
Start End Unit
10MAL14CG051C HIGH PRESSURE STEAM TURBINE CASING GV 0 0 % 12565-985130 MAL14AA051 98541000 -
BALANCE PISTON DOWNSTREAM DRAIN
VALVE 0% POSITION
10MAL19CG051B OVERLOAD VALVE UPSTREAM DRAIN VALVE GV 100 100 % 12565-985130 MAL19AA051 98541000 -
100% POSITION
10MAL19CG051C OVERLOAD VALVE UPSTREAM DRAIN VALVE GV 0 0 % 12565-985130 MAL19AA051 98541000 -
0% POSITION
10MAL20CG051B OVERLOAD VALVE DOWNSTREAM DRAIN GV 100 100 % 12565-985130 MAL20AA051 98541000 -
VALVE 100% POSITION
10MAL20CG051C OVERLOAD VALVE DOWNSTREAM DRAIN GV 0 0 % 12565-985130 MAL20AA051 98541000 -
VALVE 0% POSITION
10MAL22CG051B HIGH PRESSURE STEAM TURBINE CASING GV 100 100 % 12565-985130 MAL22AA051 98541000 -
DRAIN VALVE 100% POSITION
10MAL22CG051C HIGH PRESSURE STEAM TURBINE CASING GV 0 0 % 12565-985130 MAL22AA051 98541000 -
DRAIN VALVE 0% POSITION
MA &MEC409
10MAL23CG051B INTERCEPT EMERGENCY STOP VALVE 1 UP- GV 100 100 % 12565-985130 MAL23AA051 98541000 -
STREAM DRAIN VALVE 100% POSITION
10MAL23CG051C INTERCEPT EMERGENCY STOP VALVE 1 UP- GV 0 0 % 12565-985130 MAL23AA051 98541000 -
Index: 55
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description Application Measuring Range P&I Diag. Inst. Site Design Arrangement
Group
Start End Unit
10MAL31CG051B INTERCEPT CONTROL VALVE 1/2 DOWN- GV 100 100 % 12565-985130 MAL31AA051 98541000 -
STREAM DRAIN VALVE 100% POSITION
10MAL31CG051C INTERCEPT CONTROL VALVE 1/2 DOWN- GV 0 0 % 12565-985130 MAL31AA051 98541000 -
STREAM DRAIN VALVE 0% POSITION
10MAL41CG051B EXTRACTION 8 NON-RETURN FLAP UP- GV 100 100 % 12565-985130 MAL41AA051 98541000 -
STREAM DRAIN VALVE 100% POSITION
10MAL41CG051C EXTRACTION 8 NON-RETURN FLAP UP- GV 0 0 % 12565-985130 MAL41AA051 98541000 -
STREAM DRAIN VALVE 0% POSITION
10MAL45CG051B EXTRACTION 6 NON-RETURN FLAP UP- GV 100 100 % 12565-985130 MAL45AA051 98541000 -
STREAM DRAIN VALVE 100% POSITION
10MAL45CG051C EXTRACTION 6 NON-RETURN FLAP UP- GV 0 0 % 12565-985130 MAL45AA051 98541000 -
STREAM DRAIN VALVE 0% POSITION
10MAL47CG051B EXTRACTION 5 NON-RETURN FLAP UP- GV 100 100 % 12565-985130 MAL47AA051 98541000 -
STREAM DRAIN VALVE 100% POSITION
10MAL47CG051C EXTRACTION 5 NON-RETURN FLAP UP- GV 0 0 % 12565-985130 MAL47AA051 98541000 -
MA &MEC409
10MAL65CG051B COLD REHEAT NON-RETURN FLAP UP- GV 100 100 % 12565-985130 MAL65AA051 98541000 -
STREAM DRAIN VALVE 100% POSITION
10MAL65CG051C COLD REHEAT NON-RETURN FLAP UP- GV 0 0 % 12565-985130 MAL65AA051 98541000 -
STREAM DRAIN VALVE 0% POSITION
10MAL81CG051B SEAL STEAM MANIFOLD DRAIN VALVE 1 100% GV 100 100 % 12565-985130 MAL81AA051 98541000 -
POSITION
Index: 55
0212E
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description Application Measuring Range P&I Diag. Inst. Site Design Arrangement
Group
Start End Unit
10MAL81CG051C SEAL STEAM MANIFOLD DRAIN VALVE 1 0% GV 0 0 % 12565-985130 MAL81AA051 98541000 -
POSITION
10MAM20CT001A STEAM TURBINE INFLOW U-RING SUCTION TIRA 0 600 C 12565-984132 01360000 TT301A
TEMPERATURE
10MAM20CT001B STEAM TURBINE INFLOW U-RING SUCTION - 0 600 C 12565-984132 01360000 TT301A
TEMPERATURE
10MAM20CT002A STEAM TURBINE INFLOW U-RING SUCTION TIRA 0 600 C 12565-984132 01360000 TT301A
TEMPERATURE
10MAM20CT002B STEAM TURBINE INFLOW U-RING SUCTION - 0 600 C 12565-984132 01360000 TT301A
TEMPERATURE
10MAN52CG161 INTERMEDIATE PRESSURE BYPASS STATION GIRAS 0 100 % 12565-986727 MAN52AA161 98672000 -
1 BYPASS VALVE POSITION
10MAN52CL011 INTERMEDIATE PRESSURE BYPASS STATION LIRA 100 100 % 12565-986727 MAN52AA161 98672000 -
1 BYPASS VALVE LEAKAGE PAN LEVEL
10MAN52CP011 INTERMEDIATE PRESSURE STEAM BYPASS PIRACZ -1 19 bar 12565-986130 01360000 PA103B
MA &MEC409
WALL TEMPERATURE
10MAN52CT002A INTERMEDIATE PRESSURE BYPASS STATION TIRAZ 0 700 C 12565-986130 MAN52AA161 98677000 -
1 INJECTION ORIFICE DOWNSTREAM TUBE
WALL TEMPERATURE
10MAN52CT002B INTERMEDIATE PRESSURE BYPASS STATION - 0 700 C 12565-986130 MAN52AA161 98677000 -
1 INJECTION ORIFICE DOWNSTREAM TUBE
WALL TEMPERATURE
0212E
Index: 55
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description Application Measuring Range P&I Diag. Inst. Site Design Arrangement
Group
Start End Unit
10MAN52CT003A INTERMEDIATE PRESSURE BYPASS STATION TIRAZ 0 700 C 12565-986130 MAN52AA161 98677000 -
1 INJECTION ORIFICE DOWNSTREAM TUBE
WALL TEMPERATURE
10MAN52CT003B INTERMEDIATE PRESSURE BYPASS STATION - 0 700 C 12565-986130 MAN52AA161 98677000 -
1 INJECTION ORIFICE DOWNSTREAM TUBE
WALL TEMPERATURE
10MAN53CF001 INTERMEDIATE PRESSURE STEAM BYPASS - 0 94 kg/s 12565-986130 01360000 FE101
STATION 1 INJECTION WATER FLOW
10MAN53CF001A INTERMEDIATE PRESSURE STEAM BYPASS FIRACZ 0 94 kg/s 12565-986130 01360000 FE101
STATION 1 INJECTION WATER FLOW
10MAN53CF001B INTERMEDIATE PRESSURE STEAM BYPASS FIRACZ 0 94 kg/s 12565-986130 01360000 FE101
STATION 1 INJECTION WATER FLOW
10MAN53CF001C INTERMEDIATE PRESSURE STEAM BYPASS FIRACZ 0 94 kg/s 12565-986130 01360000 FE101
STATION 1 INJECTION WATER FLOW
10MAN53CG151 INTERMEDIATE PRESSURE STEAM BYPASS GIRAC 0 100 % 12565-986130 MAN53AA151 98676100 -
MA &MEC409
Technical Data
Steam Turbines
KKS Description Application Measuring Range P&I Diag. Inst. Site Design Arrangement
Group
Start End Unit
10MAN55CT001B INTERMEDIATE PRESSURE BYPASS STATION - 0 700 C 12565-986130 MAN55AA161 98677000 -
2 INJECTION ORIFICE DOWNSTREAM TUBE
WALL TEMPERATURE
10MAN55CT002A INTERMEDIATE PRESSURE BYPASS STATION TIRAZ 0 700 C 12565-986130 MAN55AA161 98677000 -
2 INJECTION ORIFICE DOWNSTREAM TUBE
WALL TEMPERATURE
10MAN55CT002B INTERMEDIATE PRESSURE BYPASS STATION - 0 700 C 12565-986130 MAN55AA161 98677000 -
2 INJECTION ORIFICE DOWNSTREAM TUBE
WALL TEMPERATURE
10MAN55CT003A INTERMEDIATE PRESSURE BYPASS STATION TIRAZ 0 700 C 12565-986130 MAN55AA161 98677000 -
2 INJECTION ORIFICE DOWNSTREAM TUBE
WALL TEMPERATURE
10MAN55CT003B INTERMEDIATE PRESSURE BYPASS STATION - 0 700 C 12565-986130 MAN55AA161 98677000 -
2 INJECTION ORIFICE DOWNSTREAM TUBE
WALL TEMPERATURE
MA &MEC409
Technical Data
Steam Turbines
KKS Description Application Measuring Range P&I Diag. Inst. Site Design Arrangement
Group
Start End Unit
10MAV00GS021 OIL SUPPLY UNIT FIRE PROTECTION TRIP SIRZ 100 100 % CCR -
CONTROL ROOM PUSHBUTTON
10MAV00GS022 OIL SUPPLY UNIT EMERGENCY OPERATION SIRZ 100 100 % LOCAL -
PUSHBUTTON
10MAV00GS023 OIL SUPPLY UNIT EMERGENCY OPERATION SIRZ 100 100 % LOCAL -
ESCAPE ROUTE 1 PUSHBUTTON
10MAV00GS024 OIL SUPPLY UNIT EMERGENCY OPERATION SIRZ 100 100 % LOCAL -
ESCAPE ROUTE 2 PUSHBUTTON
10MAV10CL021 MAIN LUBRICATING OIL TANK LEVEL LIRAZ 850 1750 mm 12565-981136 MAV10BB001 98153000 -
10MAV10CL022 MAIN LUBRICATING OIL TANK LEVEL LIRAZ 850 1750 mm 12565-981136 MAV10BB001 98153000 -
10MAV10CL023 MAIN LUBRICATING OIL TANK LEVEL LIRAZ 850 1750 mm 12565-981136 MAV10BB001 98153000 -
10MAV10CL521 MAIN LUBRICATING OIL TANK LEVEL LI 850 1750 mm 12565-981136 MAV10BB001 98153000 -
10MAV10CP480 MAIN LUBRICATING OIL TANK OPTION 1 PRES- PK -1.0 1.5 bar 12565-981136 MAV10BB001 98153000 -
SURE
10MAV10CT001A MAIN LUBRICATING OIL TANK TEMPERATURE TIRAS 0 100 C 12565-981136 MAV10BB001 98153000 -
MA &MEC409
10MAV10CT001B MAIN LUBRICATING OIL TANK TEMPERATURE - 0 100 C 12565-981136 MAV10BB001 98153000 -
10MAV21CP001 LUBE OIL PUMP TEST / LUBE OIL PRESSURE PIRAS 0.5 10 bar 12565-981136 MAV10BB001 98153000 -
10MAV31CP501 LIFTING OIL PUMP 1 DOWNSTREAM PRES- PI 0 400 bar 12565-981141 MAV10BB001 98153000 -
SURE
10MAV32CP001 LIFTING OIL PUMP 2 DOWNSTREAM PRES- PIRAS 0 250 bar 12565-981141 MAV10BB001 98153000 -
SURE
10MAV32CP501 LIFTING OIL PUMP 2 DOWNSTREAM PRES- PI 0 400 bar 12565-981141 MAV10BB001 98153000 -
SURE
10MAV35CP001 LIFTING OIL PRESSURE PIRAS 0 250 bar 12565-981136 MAV10BB001 98153000 -
0212E
Index: 55
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description Application Measuring Range P&I Diag. Inst. Site Design Arrangement
Group
Start End Unit
10MAV35CP016 LIFTING OIL FILTER DIFFERENTIAL PRES- PDIRA 0 4.2 bar 12565-981141 MAV10BB001 98153000 -
SURE
10MAV35CP501 LIFTING OIL PRESSURE PI 0 400 bar 12565-981141 MAV10BB001 98153000 -
10MAV41CP481 LUBE OIL OPTION 4 PRESSURE PK 0 10 bar 12565-981136 MAV10BB001 98153000 -
10MAV42CP012 STEAM TURBINE BEARING LUBE OIL PRES- PS 0.5 10 bar 12565-981136 MAV10BB001 98153000 -
SURE / EMERGENCY OIL PUMP START
10MAV42CP013 STEAM TURBINE BEARING LUBE SUPPLY OIL PDIRA 0 1.2 bar 12565-981136 MAV10BB001 98153000 -
FILTER DIFFERENTIAL PRESSURE
10MAV42CP016 STEAM TURBINE BEARING LUBE OIL SUPPLY PIRAZ 0 6 bar 12565-981136 MAV10BB001 98153000 -
FILTER DOWNSTREAM PRESSURE
10MAV42CP017 STEAM TURBINE BEARING LUBE OIL SUPPLY PIRAZ 0 6 bar 12565-981136 MAV10BB001 98153000 -
FILTER DOWNSTREAM PRESSURE
10MAV42CP018 STEAM TURBINE BEARING LUBE OIL SUPPLY PIRAZ 0 6 bar 12565-981136 MAV10BB001 98153000 -
FILTER DOWNSTREAM PRESSURE
10MAV42CP019 STEAM TURBINE BEARING LUBE OIL SUPPLY PIRAS 0.5 10 bar 12565-981136 MAV10BB001 98153000 -
MA &MEC409
Technical Data
Steam Turbines
KKS Description Application Measuring Range P&I Diag. Inst. Site Design Arrangement
Group
Start End Unit
10MAV42CT001B STEAM TURBINE BEARING LUBE OIL TEMPER- - 0 100 C 12565-981136 MAV10BB001 98153000 -
ATURE CONTROL VALVE DOWNSTREAM TEM-
PERATURE
10MAV42CT002A STEAM TURBINE BEARING LUBE OIL TEMPER- TIRAS 0 100 C 12565-981136 MAV10BB001 98153000 -
ATURE CONTROL VALVE DOWNSTREAM TEM-
PERATURE
10MAV42CT002B STEAM TURBINE BEARING LUBE OIL TEMPER- - 0 100 C 12565-981136 MAV10BB001 98153000 -
ATURE CONTROL VALVE DOWNSTREAM TEM-
PERATURE
10MAV42CT501 STEAM TURBINE BEARING LUBE OIL TEMPER- TI 0 100 C 12565-981136 MAV10BB001 98153000 -
ATURE CONTROL VALVE DOWNSTREAM TEM-
PERATURE
10MAV44CP411 GENERATOR TURBINE SIDE BEARING LUBE PK 0 4 bar 12565-981131 -
OIL ADJUSTING VALVE DOWNSTREAM PRES-
SURE
MA &MEC409
SURE
10MAV66CP510 STEAM TURBINE FRONT BEARING 3 LIFTING PI 0 250 bar 12565-982131 MAD13HD001 26170000 -
OIL ADJUSTING VALVE 2 DOWNSTREAM
PRESSURE
10MAV66CP513 STEAM TURBINE FRONT BEARING 4 LIFTING PI 0 250 bar 12565-982131 MAD14HD001 -
OIL ADJUSTING VALVE DOWNSTREAM PRES-
SURE
Index: 55
0212E
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description Application Measuring Range P&I Diag. Inst. Site Design Arrangement
Group
Start End Unit
10MAV66CP514 STEAM TURBINE FRONT BEARING 4 LIFTING PI 0 250 bar 12565-982131 MAD14HD001 -
OIL ADJUSTING VALVE 2 DOWNSTREAM
PRESSURE
10MAV66CP517 STEAM TURBINE FRONT BEARING 5 LIFTING PI 0 250 bar 12565-982131 MAD15HD001 -
OIL ADJUSTING VALVE DOWNSTREAM PRES-
SURE
10MAV66CP518 STEAM TURBINE FRONT BEARING 5 LIFTING PI 0 250 bar 12565-982131 MAD15HD001 -
OIL ADJUSTING VALVE 2 DOWNSTREAM
PRESSURE
10MAV67CP501 TURBINE SIDE GENERATOR FRONT BEARING PI 0 250 bar 12565-982131 MKD11HD001 -
LIFTING OIL ADJUSTING VALVE DOWN-
STREAM PRESSURE
10MAV67CP502 TURBINE SIDE GENERATOR REAR BEARING PI 0 250 bar 12565-982131 MKD11HD001 -
LIFTING OIL ADJUSTING VALVE DOWN-
STREAM PRESSURE
MA &MEC409
10MAV67CP503 EXCITER SIDE GENERATOR FRONT BEARING PI 0 250 bar 12565-982131 MKD12HD001 -
LIFTING OIL ADJUSTING VALVE DOWN-
STREAM PRESSURE
Technical Data
Steam Turbines
KKS Description Application Measuring Range P&I Diag. Inst. Site Design Arrangement
Group
Start End Unit
10MAV72CT401 GENERATOR TURBINE SIDE BEARING RE- TK 0 100 C 12565-981131 -
TURN OIL TEMPERATURE
10MAV72CT402 GENERATOR EXCITER SIDE BEARING RE- TK 0 100 C 12565-981131 -
TURN OIL TEMPERATURE
10MAV73CT401 EXCITER BEARING RETURN OIL TEMPERA- TK 0 100 C 12565-981131 -
TURE
10MAV82CP001 OIL VAPOUR EXHAUST OIL SEPARATOR UP- PIRAS 0 -15 mbar 12565-981136 MAV10BB001 98153000 -
STREAM MANIFOLD PRESSURE
10MAV82CP482 OIL VAPOUR EXHAUST OPTION 3 PRESSURE PK 0 10 bar 12565-981136 MAV10BB001 98153000 -
10MAV82CP501 OIL VAPOUR EXHAUST OIL SEPARATOR UP- PI -60 0 mbar 12565-981136 MAV10BB001 98153000 -
STREAM PRESSURE
10MAV82CP502 OIL VAPOUR EXHAUST OIL SEPARATOR PI -160 0 mbar 12565-981136 MAV10BB001 98153000 -
PRESSURE
10MAV85CL021 OIL DISCHARGE TANK LEVEL LIRA 0 100 % 12565-981133 MAV85BB001 01360000 -
10MAV85CL521 OIL DISCHARGE TANK LEVEL LI 0 100 % 12565-981133 MAV85BB001 981530000 -
MA &MEC409
10MAV89CL021 WASTE OIL TANK LEVEL LIRA 0 100 % 12565-981135 MAV89BB001 98150100 -
10MAV89CL521 WASTE OIL TANK LEVEL LI 0 100 % 12565-981135 MAV89BB001 98150100 -
10MAW20CT001B SEAL STEAM MANIFOLD FRONT TEMPERA- - 0 400 C 12565-984131 01360000 TT301A
TURE
10MAW20CT003A SEAL STEAM MANIFOLD REAR TEMPERA- TIRAC 0 400 C 12565-984131 01360000 TT301A
TURE
10MAW20CT003B SEAL STEAM MANIFOLD REAR TEMPERA- - 0 400 C 12565-984131 01360000 TT301A
TURE
Index: 55
0212E
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description Application Measuring Range P&I Diag. Inst. Site Design Arrangement
Group
Start End Unit
10MAW50CG151 LEAK-OFF STEAM DISCHARGE CONTROL GIR 0 100 % 12565-984131 MAW50AA151 98451400 -
VALVE POSITION
10MAW60CT001A LEAK-OFF STEAM MANIFOLD TEMPERATURE TIR 0 600 C 12565-984131 01360000 TT301
10MAW60CT001B LEAK-OFF STEAM MANIFOLD TEMPERATURE - 0 600 C 12565-984131 01360000 TT301
10MAX01CL001 CONTROL FLUID SUPPLY UNIT TANK LEVEL LIRAS 100 100 % 12565-983140 MAX01 98353000 -
10MAX01CL011 CONTROL FLUID SUPPLY UNIT DRAIN PAN LIRA 100 100 % 12565-983140 MAX01 98353000 -
LEVEL
10MAX01CL501 CONTROL FLUID SUPPLY UNIT TANK LEVEL LI 0 300 mm 12565-983140 MAX01 98353000 -
10MAX01CP001 CONTROL FLUID SUPPLY PUMP 1 DOWN- PIRAS 0 250 bar 12565-983140 MAX01 98353000 -
STREAM PRESSURE
10MAX01CP002 CONTROL FLUID SUPPLY PUMP 2 DOWN- PIRAS 0 250 bar 12565-983140 MAX01 98353000 -
STREAM PRESSURE
10MAX01CP003 CONTROL FLUID SUPPLY UNIT CONNEC- PIRAS 0 250 bar 12565-983140 MAX01 98353000 -
TIONS PRESSURE
10MAX01CP004 CONTROL FLUID COOLING CIRCIUT 1 FAN PIRAS 0.05 1.0 bar 12565-983140 MAX01 98353000 -
MA &MEC409
UPSTREAM PRESSURE
10MAX01CP401 CONTROL FLUID SUPPLY PUMP 1 FILTER UP- PK 0 250 bar 12565-983140 MAX01 98353000 -
STREAM PRESSURE
10MAX01CP402 CONTROL FLUID SUPPLY PUMP 2 FILTER UP- PK 0 250 bar 12565-983140 MAX01 98353000 -
STREAM PRESSURE
10MAX01CP403 CONTROL FLUID SUPPLY PUMP 1 FILTER PK 0 250 bar 12565-983140 MAX01 98353000 -
DOWNSTREAM PRESSURE
Index: 55
0212E
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description Application Measuring Range P&I Diag. Inst. Site Design Arrangement
Group
Start End Unit
10MAX01CP404 CONTROL FLUID SUPPLY PUMP 2 FILTER PK 0 250 bar 12565-983140 MAX01 98353000 -
DOWNSTREAM PRESSURE
10MAX01CP411 CONTROL FLUID ACCUMULATOR 1 PRES- PK 0 250 bar 12565-983140 MAX01 98353000 -
SURE
10MAX01CP412 CONTROL FLUID ACCUMULATOR 2 PRES- PK 0 250 bar 12565-983140 MAX01 98353000 -
SURE
10MAX01CP413 CONTROL FLUID ACCUMULATOR 3 PRES- PK 0 250 bar 12565-983140 MAX01 98353000 -
SURE
10MAX01CP414 CONTROL FLUID ACCUMULATOR 4 PRES- PK 0 250 bar 12565-983140 MAX01 98353000 -
SURE
10MAX01CP501 CONTROL FLUID SUPPLY UNIT CONNEC- PI 0 400 bar 12565-983140 MAX01 98353000 -
TIONS PRESSURE
10MAX01CP504 CONTROL FLUID COOLING CIRCIUT 1 FAN PI 0 10 bar 12565-983140 MAX01 98353000 -
COOLER UPSTREAM PRESSURE
10MAX01CP505 CONTROL FLUID COOLING CIRCIUT 2 FAN PI 0 10 bar 12565-983140 MAX01 98353000 -
MA &MEC409
10MAX01CT001B CONTROL FLUID SUPPLY UNIT TANK TEMPER- TIRAS 0 100 C 12565-983140 MAX01 98353000 -
ATURE
10MAX01GS001 CONTROL FLUID SUPPLY UNIT EMERGENCY Z 100 100 % 12565-983140 MAX01 98353000 -
STOP PUSHBUTTON
10MAX05CL001 CONTROL FLUID SUPPLY UNIT TANK LEVEL LIRAS 100 100 % 12565-983150 MAX05 98353000 -
10MAX05CL011 CONTROL FLUID SUPPLY UNIT DRAIN PAN LIRA 100 100 % 12565-983150 MAX05 98353000 -
LEVEL
0212E
Index: 55
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description Application Measuring Range P&I Diag. Inst. Site Design Arrangement
Group
Start End Unit
10MAX05CL501 CONTROL FLUID SUPPLY UNIT TANK LEVEL LI 0 300 mm 12565-983150 MAX05 98353000 -
10MAX05CP001 CONTROL FLUID SUPPLY PUMP 1 DOWN- PIRAS 0 250 bar 12565-983150 MAX05 98353000 -
STREAM PRESSURE
10MAX05CP002 CONTROL FLUID SUPPLY PUMP 2 DOWN- PIRAS 0 250 bar 12565-983150 MAX05 98353000 -
STREAM PRESSURE
10MAX05CP003 CONTROL FLUID SUPPLY UNIT CONNEC- PIRAS 0 250 bar 12565-983150 MAX05 98353000 -
TIONS PRESSURE
10MAX05CP004 CONTROL FLUID COOLING CIRCIUT 1 FAN PIRAS 0.05 1.0 bar 12565-983150 MAX05 98353000 -
COOLER UPSTREAM PRESSURE
10MAX05CP005 CONTROL FLUID COOLING CIRCIUT 2 FAN PIRAS 0.05 1.0 bar 12565-983150 MAX05 98353000 -
COOLER UPSTREAM PRESSURE
10MAX05CP011 CONTROL FLUID SUPPLY PUMP 1 DOWN- PDIRA 0 5 bar 12565-983150 MAX05 98353000 -
STREAM FILTER DIFFERENTIAL PRESSURE
10MAX05CP012 CONTROL FLUID SUPPLY PUMP 2 DOWN- PDIRA 0 5 bar 12565-983150 MAX05 98353000 -
STREAM FILTER DIFFERENTIAL PRESSURE
MA &MEC409
10MAX05CP013 CONTROL FLUID COOLING CIRCIUT 1 FILTER PIRA 0 2 bar 12565-983150 MAX05 98353000 -
UPSTREAM PRESSURE
10MAX05CP014 CONTROL FLUID COOLING CIRCIUT 2 FILTER PIRA 0 2 bar 12565-983150 MAX05 98353000 -
10MAX05CP404 CONTROL FLUID SUPPLY PUMP 2 FILTER PK 0 250 bar 12565-983150 MAX05 98353000 -
DOWNSTREAM PRESSURE
10MAX05CP411 CONTROL FLUID ACCUMULATOR 1 PRES- PK 0 250 bar 12565-983150 MAX05 98353000 -
SURE
10MAX05CP412 CONTROL FLUID ACCUMULATOR 2 PRES- PK 0 250 bar 12565-983150 MAX05 98353000 -
SURE
10MAX05CP413 CONTROL FLUID ACCUMULATOR 3 PRES- PK 0 250 bar 12565-983150 MAX05 98353000 -
SURE
0212E
Index: 55
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description Application Measuring Range P&I Diag. Inst. Site Design Arrangement
Group
Start End Unit
10MAX05CP414 CONTROL FLUID ACCUMULATOR 4 PRES- PK 0 250 bar 12565-983150 MAX05 98353000 -
SURE
10MAX05CP501 CONTROL FLUID SUPPLY UNIT CONNEC- PI 0 400 bar 12565-983150 MAX05 98353000 -
TIONS PRESSURE
10MAX05CP504 CONTROL FLUID COOLING CIRCIUT 1 FAN PI 0 10 bar 12565-983150 MAX05 98353000 -
COOLER UPSTREAM PRESSURE
10MAX05CP505 CONTROL FLUID COOLING CIRCIUT 2 FAN PI 0 10 bar 12565-983150 MAX05 98353000 -
COOLER UPSTREAM PRESSURE
10MAX05CP506 CONTROL FLUID TREATMENT CIRCUIT FINE PI 0 10 bar 12565-983150 MAX05 98353000 -
MESH FILTER UPSTREAM PRESSURE
10MAX05CP511 CONTROL FLUID ACCUMULATOR 1 PRES- PI 0 250 bar 12565-983150 MAX05 98353000 -
SURE
10MAX05CP512 CONTROL FLUID ACCUMULATOR 2 PRES- PI 0 250 bar 12565-983150 MAX05 98353000 -
SURE
10MAX05CP513 CONTROL FLUID ACCUMULATOR 3 PRES- PI 0 250 bar 12565-983150 MAX05 98353000 -
MA &MEC409
SURE
10MAX05CP514 CONTROL FLUID ACCUMULATOR 4 PRES- PI 0 250 bar 12565-983150 MAX05 98353000 -
SURE
Index: 55
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description Application Measuring Range P&I Diag. Inst. Site Design Arrangement
Group
Start End Unit
10QFB01CP011 CONTROL AIR MANIFOLD FILTER DIFFEREN- PDIRA 0 1 bar 12565-988130 01360000 -
TIAL PRESSURE
Index: 55
MA &MEC409
Abbreviations / Abkrzungen
Column Title / Spal- Abbreviation / Description Beschreibung
tentitel Abkrzung
Drive / Antrieb
BB Black Box Black Box / LET
BBC Black Box connected by another
Black Box
BBD Black Box , with high starting duty
BBH Black Box , with space heater Black Box / LET , mit Stillstands hei-
zung
BBHD Like "BBH", with high starting duty
BBHS Wie "BBH" , mit Schweranlauf
BBS Black Box / LET , mit Schweranlauf
CB Connecting busbar
CC Connecting cable ( Electrical cou-
pling / -tie )
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
E Elektromotorischer Antrieb
EA Electric motor drive actuator
of a utility model or design, are reserved.
EH Elektro-Hydraulischer Antrieb
EI Electric Actuator with Integral Power
Control
EL Elektromotorischer Regelantrieb
ER Elektromotorischer Regelantrieb
ES Elektromotorischer Stellantrieb
ESB Wie "ES" mit zustzlicher Bremse
ESH Wie "ES", mit Stillstandsheizung
HZ Heizungen
KA Kabelabzweig (ungesteuert)
KE Kabeleinspeisung
Copyright Siemens AG 2006 - All Rights Reserved
KV Kabelverbindung
MO Electric motor drive for processing Elektromotorischer Antrieb fr Ar-
of a utility model or design, are reserved.
machine beitsmaschine
MOD Like "MO", with high starting duty
MOG Wie "MO", Drehzahlgeregelt
MOH Like "MO", with space heater Wie "MO", mit Stillstandsheizung
(Heat output of space heater: (Heizleistung der Stillstandsheizung:
AC-Motors: SH10 = 25W; SH11= DS-Motoren: SH10 = 25W; SH11=
50W; SH12 = 78W; SH13 = 98W; 50W; SH12 = 78W; SH13 = 98W;
SH14 = 100W SH14 = 100W
DC-Motors: SH20 = 30W; SH21 = GS-Motoren: SH20 = 30W; SH21 =
60W; SH22 = 90W; SH23 = 120W; 60W; SH22 = 90W; SH23 = 120W;
SH24 = 150W) SH24 = 150W)
MOHD Like "MOH", with high starting duty
MOHG Wie "MOH", Drehzahlgeregelt
MOHR Like "MOH", reverse direction Wie "MOH", Reversier-Betrieb
Class: FOR INTERNAL USE ONLY
tentitel
Energy Sector
Spannungsart
Technical Data
Steam Turbines
Siemens AG
Column Title / Spal-
D
G
W
Abkrzung
Abbreviation /
Description
MA &MAC019
Lists
Drehstrom
Gleichstrom
Wechselstrom
Beschreibung
List of Electrical Loads / Explanations
0206E
1.1.3-33010-00001 / 6-6
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
Motors
KKS Description Type Grid Volt- Rated Req. Cur- Start / Sub- Volt- P&I Diag. Design Remark
of age Power Power rent nominal distri- age Group
Drive Current butor type
[V] [W] [W] [A] [A]
10CJJ11GW001 STEAM TURBINE GOVERNOR I&C CF DC1 24 1200 960 50 1 Y DC 12565-931410 PWR SUP 1 I&C
CABINET POWER SUPPLY 1 CAB
10CJJ11GW002 STEAM TURBINE GOVERNOR I&C CF DC2 24 1200 960 50 1 Y DC 12565-931410 PWR SUP 2 I&C
CABINET POWER SUPPLY 2 CAB
10CJJ21GW001 STEAM TURBINE MEASUREMENT CF DC1 24 480 384 20 1 Y DC 12565-931410 PWR SUP 1 I&C
I&C CABINET POWER SUPPLY 1 CAB
10CJJ21GW002 STEAM TURBINE MEASUREMENT CF DC2 24 480 384 20 1 Y DC 12565-931410 PWR SUP 2 I&C
I&C CABINET POWER SUPPLY 2 CAB
10CJJ22GW001 STEAM TURBINE CONTROL/PRO- CF DC1 24 480 384 20 1 Y DC 12565-931410 PWR SUP 1 I&C
TECTION I&C CABINET POWER SUP- CAB
PLY 1
10CJJ22GW002 STEAM TURBINE CONTROL/PRO- CF DC2 24 480 384 20 1 Y DC 12565-931410 PWR SUP 2 I&C
TECTION I&C CABINET POWER SUP- CAB
MA &MEC489
PLY 2
10CKA00GK701 WIN TS PRINTER CF NU 230 640 60 6 1 Y 1AC PWR SUP CR
10CKA01GK501 WIN TS MONITOR CF NU 230 120 90 1 1 Y 1AC PWR SUP CR
Technical Data
Steam Turbines
KKS Description Type Grid Volt- Rated Req. Cur- Start / Sub- Volt- P&I Diag. Design Remark
of age Power Power rent nominal distri- age Group
Drive Current butor type
[V] [W] [W] [A] [A]
10CPG21GW002 HYDROGEN CABINET POWER SUP- CF DC2 24 506 405 21 1 Y 1AC 12565-931410 PWR SUP 2 H2
PLY 2 CAB
10CPG21GW021 H2 CABINET POWER SUPPLY 1 CF NU 230 230 184 1 1 Y 1AC 12565-931410 PWR SUP 1 H2
CAB
10CPG21GW022 H2 CABINET POWER SUPPLY 2 CF NU 230 230 184 1 1 Y 1AC 12565-931410 PWR SUP 2 H2
CAB
10CRU01GJ101 OPERATOR PERSONAL COMPUTER CF NU 230 525 120 2.5 1 Y 1AC PWR SUP CR
LARGE VIDEO SCREEN
10CRU01GJ102 OPERATOR PERSONAL COMPUTER CF NU 230 525 120 2.5 1 Y 1AC PWR SUP CR
LARGE VIDEO SCREEN
10CRU02GJ101 OPERATOR ENGINEERING PERSON- CF NU 230 525 120 2.5 1 Y 1AC PWR SUP CR
AL COMPUTER
10CRU02GJ102 OPERATOR ENGINEERING PERSON- CF NU 230 525 120 2.5 1 Y 1AC PWR SUP CR
AL COMPUTER
MA &MEC489
Technical Data
Steam Turbines
KKS Description Type Grid Volt- Rated Req. Cur- Start / Sub- Volt- P&I Diag. Design Remark
of age Power Power rent nominal distri- age Group
Drive Current butor type
[V] [W] [W] [A] [A]
10MAV31AP001 LIFTING OIL PUMP 1 MO N1 415 82800 73200 142 8.2 Y 3AC 12565-981141 98153000
10MAV32AP001 LIFTING OIL PUMP 2 MO ED 415 82800 73200 142 8.2 Y 3AC 12565-981141 98153000
10MAV41AA101 LUBE OIL TEMPERATURE CONTROL CF N1 230 2 N 1AC 12565-981136 98153000 CONN TO
VALVE MAV41GH001
10MAV41GH001 LUBE OIL TEMPERATURE CONTROL- CF N1 415 2 Y 3AC 12565-981136 98153000 BB FUSE: 6 A
LER TERMINAL BOX
10MAV82AN001 OIL VAPOUR EXTRACTOR 1 MO N1 415 2200 5.1 6.3 Y 3AC 12565-981136 98153000
10MAV82AN002 OIL VAPOUR EXTRACTOR 2 MO ED 415 2200 5.1 6.3 Y 3AC 12565-981136 98153000
10MAV86AP011 OIL DISCHARGE TANK FEEDBACK MO N1 415 750 1.91 4.2 N 3AC 12565-981133 CONN TO
PUMP MAV93AT001
10MAV91AT001 OIL SEPARATOR CF N1 415 40000 56 Y 3AC 12565-981139 90255300 BB-FS: 63A
10MAX01AP001 CONTROL FLUID SUPPLY PUMP 1 MO N1 415 18500 12000 35.5 7.5 Y 3AC 12565-983140 98353000
10MAX01AP002 CONTROL FLUID SUPPLY PUMP 2 MO N2 415 15000 10000 28.5 6.5 Y 3AC 12565-983140 98353000
10MAX01AP011 CONTROL FLUID CIRCULATION MO N1 415 2200 1300 4.7 5.6 Y 3AC 12565-983140 98353000
MA &MEC489
PUMP 1
10MAX01AP012 CONTROL FLUID CIRCULATION MO N2 415 2200 1300 4.7 5.6 Y 3AC 12565-983140 98353000
Technical Data
Steam Turbines
Solenoid Valves
KKS Description Type Grid Voltage Rated Cur- Sub- Volt- P&I Diag. Design Remark
of Power rent distri- age Group
Drive butor type
[V] [W] [A]
10LBC10AA051A COLD REHEAT NON-RETURN FLAP 1 PILOT VALVE 1 SV DC 24 16 .67 N DC 12565-986132
10LBC10AA051B COLD REHEAT NON-RETURN FLAP 1 PILOT VALVE 2 SV DC 24 16 .67 N DC 12565-986132
10LBC41AA051A HIGH PRESSURE TURBINE EVACUATION CONTROL SV DC 24 39 1.63 N DC 12565-986132
VALVE PILOT VALVE 1
10LBC41AA051B HIGH PRESSURE TURBINE EVACUATION CONTROL SV DC 24 39 1.63 N DC 12565-986132
VALVE PILOT VALVE 2
10LBQ60AA051A EXTRACTION 6 NON-RETURN FLAP 1 PILOT VALVE SV DC 24 16 .67 N DC 12565-986132
10LBQ80AA051A EXTRACTION 8 NON-RETURN FLAP 1 PILOT VALVE SV DC 24 16 .67 N DC 12565-986132
10LBS30AA051A EXTRACTION 3 NON-RETURN FLAP 1 PILOT VALVE SV DC 24 16 .67 N DC 12565-986132
10LBS31AA051A EXTRACTION 3 NON-RETURN FLAP 1 PILOT VALVE SV DC 24 16 .67 N DC 12565-986132
10LBS40AA051A EXTRACTION 4 NON-RETURN FLAP 1 PILOT VALVE SV DC 24 16 .67 N DC 12565-986132
10LBS50AA051A EXTRACTION 5 NON-RETURN FLAP 1 PILOT VALVE SV DC 24 16 .67 N DC 12565-986132
MA &MEC489
Index: 54
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description Type Grid Voltage Rated Cur- Sub- Volt- P&I Diag. Design Remark
of Power rent distri- age Group
Drive butor type
[V] [W] [A]
10MAA21AA014 MAIN STEAM EMERGENCY STOP VALVE 2 EMERGEN- SV DC 24 17 .71 N DC 12565-931502
CY TRIP PILOT VALVE 2
10MAA22AA012 MAIN STEAM CONTROL VALVE 2 SERVO VALVE SV DC 24 1.4 .03 N DC 12565-931552 +/- 30 mA per coil
10MAA22AA013 MAIN STEAM CONTROL VALVE 2 EMERGENCY TRIP SV DC 24 17 .71 N DC 12565-931552
PILOT VALVE 1
10MAA22AA014 MAIN STEAM CONTROL VALVE 2 EMERGENCY TRIP SV DC 24 17 .71 N DC 12565-931552
PILOT VALVE 2
10MAB11AA011 INTERCEPT EMERGENCY STOP VALVE 1 CONTROL SV DC 24 30 1.25 N DC 12565-931531
VALVE
10MAB11AA013 INTERCEPT EMERGENCY STOP VALVE 1 EMERGEN- SV DC 24 17 .71 N DC 12565-931531
CY TRIP PILOT VALVE 1
10MAB11AA014 INTERCEPT EMERGENCY STOP VALVE 1 EMERGEN- SV DC 24 17 .71 N DC 12565-931531
CY TRIP PILOT VALVE 2
10MAB12AA012 INTERCEPT CONTROL VALVE 1 SERVO VALVE SV DC 24 1.4 .03 N DC 12565-931581 +/- 30 mA per coil
MA &MEC489
Technical Data
Steam Turbines
KKS Description Type Grid Voltage Rated Cur- Sub- Volt- P&I Diag. Design Remark
of Power rent distri- age Group
Drive butor type
[V] [W] [A]
10MAG20AA051A CONDENSER 2 VACUUM BREAKER CONTROL VALVE SV DC 24 16 .67 N DC 12565-986131 98679000
PILOT VAVLE
10MAL11AA051A MAIN STEAM CONTROL VALVE 1 UPSTREAM DRAIN SV DC 24 16 .67 N DC 12565-985130 98541000
VALVE PILOT VALVE
10MAL12AA051A MAIN STEAM CONTROL VALVE 2 UPSTREAM DRAIN SV DC 24 16 .67 N DC 12565-985130 98541000
VALVE PILOT VALVE
10MAL14AA051A HIGH PRESSURE STEAM TURBINE CASING BALANCE SV DC 24 16 .67 N DC 12565-985130 98541000
PISTON DOWNSTREAM DRAIN VALVE PILOT VALVE
10MAL19AA051A OVERLOAD VALVE UPSTREAM DRAIN VALVE PILOT SV DC 24 16 .67 N DC 12565-985130 98541000
VALVE
10MAL20AA051A OVERLOAD VALVE DOWNSTREAM DRAIN VALVE PI- SV DC 24 16 .67 N DC 12565-985130 98541000
LOT VALVE
10MAL22AA051A HIGH PRESSURE STEAM TURBINE CASING DRAIN SV DC 24 16 .67 N DC 12565-985130 98541000
VALVE 1 PILOT VALVE
MA &MEC489
Technical Data
Steam Turbines
KKS Description Type Grid Voltage Rated Cur- Sub- Volt- P&I Diag. Design Remark
of Power rent distri- age Group
Drive butor type
[V] [W] [A]
10MAL51AA051A EXTRACTION 4 NON-RETURN FLAP UPSTREAM SV DC 24 16 .67 N DC 12565-985130 98541000
DRAIN VALVE PILOT VALVE
10MAL54AA051A EXTRACTION 3 NON-RETURN FLAP UPSTREAM SV DC 24 16 .67 N DC 12565-985130 98541000
DRAIN VALVE PILOT VALVE
10MAL55AA051A EXTRACTION 3 NON-RETURN FLAP UPSTREAM SV DC 24 16 .67 N DC 12565-985130 98541000
DRAIN VALVE PILOT VALVE
10MAL65AA051A COLD REHEAT NON-RETURN FLAP UPSTREAM DRAIN SV DC 24 16 .67 N DC 12565-985130 98541000
VALVE PILOT VALVE
10MAL81AA051A SEAL STEAM MANIFOLD DRAIN VALVE 1 PILOT VALVE SV DC 24 16 .67 N DC 12565-985130 98541000
10MAN52AA012 INTERMEDIATE PRESSURE BYPASS STATION 1 BY- SV DC 24 1.2 .05 N DC 12565-986727 98672000 +/- 50 mA per coil
PASS VALVE ACTUATOR SERVO VALVE
10MAN52AA013 INTERMEDIATE PRESSURE BYPASS STATION 1 BY- SV DC 24 17 .71 N DC 12565-986727 98672000
PASS VALVE PILOT VALVE 1
10MAN52AA014 INTERMEDIATE PRESSURE BYPASS STATION 1 BY- SV DC 24 17 .71 N DC 12565-986727 98672000
MA &MEC489
Technical Data
Steam Turbines
KKS Description Type Grid Voltage Rated Cur- Sub- Volt- P&I Diag. Design Remark
of Power rent distri- age Group
Drive butor type
[V] [W] [A]
10MAW50AA151T LEAK-OFF STEAM DISCHARGE CONTROL VALVE SV DC 24 1 .02 N DC 12565-984131 98451400 4-20 mA
CONTROL AIR CONTROL COIL
Index: 54
MA &MEC489
Technical Data
Steam Turbines
Stop and Control Valves
KKS Description Type Grid Volt- Rated Req. Cur- Start / Sub- Volt- P&I Diag. Design Remark
of age Power Power rent nominal distri- age Group
Drive Current butor type
[V] [W] [W] [A] [A]
10MAW10AA152 SEAL STEAM SUPPLY CONTROL EAI N1 415 750 3.5 Y 3AC 12565-984131 98451400 SIPOS , FS 6A
VALVE BYPASS ADJUSTING VALVE SLOW BLOW-
ING
10MAW10AA252 SEAL STEAM SUPPLY CONTROL EAI N1 415 750 3 Y 3AC 12565-984131 98451400 SIPOS , FS 6A
VALVE UPSTREAM ISOLATING SLOW BLOW-
VALVE ING
10MAW50AA152 LEAK-OFF STEAM DISCHARGE CON- EAI N1 415 1500 4 Y 3AC 12565-984131 98451400 SIPOS , FS 6A
TROL VALVE BYPASS ADJUSTING SLOW BLOW-
VALVE ING
10MAW50AA252 LEAK-OFF STEAM DISCHARGE CON- EAI N1 415 1500 5 Y 3AC 12565-984131 98451400 SIPOS , FS 10A
TROL VALVE UPSTREAM ISOLATING SLOW BLOW-
VALVE ING
Index: 54
MA &MEC489
Technical Data
Steam Turbines
KKS Description P&I Diag. Remark
Manufacturer Type Manuf. PN Casing DN In Length In Total Heigth Des. Press./Tmp. Spindle Jointing
Supplier Drawing No. PN In DN Out1 Length Out Ambient Tmp. Op. Press./Tmp. Medium
Design Group Material Casing PN Out DN Out2 Length Tot. Differential Weight
Unit /// /// bar Diam.Cl. mm mm/C/C bar/C //Kg
10LBC10AA051 COLD REHEAT NON-RETURN FLAP 1 12565-986132
FA. SEMPELL 800 935 /
12565-980330/001 800 / DAMPF
09000100 2150 5-45 7620
10LBC10AA261 LBC10AA051A PILOT VALVE 1 UPSTREAM PRESSURE REDUCING VALVE 12565-986132 SUPPLIED WITH LBC10AA051
/
/
09000100 -
10LBC41AA051 HIGH PRESSURE TURBINE EVACUATION CONTROL VALVE 12565-986132
WELLAND & TUXHORN ASV-1-1-GE-DS 150 1250 69.1/393
12565-980340/001 600 250 / STEAM
MA &MPD019
Valve List
Lists
/
98970000 -
10LBQ60AA051 EXTRACTION 6 NON-RETURN FLAP 1 12565-986132 TIN PSK046N187
FA. SEMPELL 803-333RL 300 490 30.5/490
12565-980333/002 300 / DAMPF
08600100 850 5-45 850
10LBQ60AA052 EXTRACTION 6 NON-RETURN FLAP 2 12565-986132 TIN PSK046N456
FA. SEMPELL 803-331L 300 490 30.5/4901
12565-980334/002 300 / DAMPF
1.1.3-34100-12565 / 1-33
Technical Data
Steam Turbines
KKS Description P&I Diag. Remark
Manufacturer Type Manuf. PN Casing DN In Length In Total Heigth Des. Press./Tmp. Spindle Jointing
Supplier Drawing No. PN In DN Out1 Length Out Ambient Tmp. Op. Press./Tmp. Medium
Design Group Material Casing PN Out DN Out2 Length Tot. Differential Weight
Unit /// /// bar Diam.Cl. mm mm/C/C bar/C //Kg
10LBQ80AA052 EXTRACTION 8 NON-RETURN FLAP 2 12565-986132 TIN PSK048Q737
FA. SEMPELL 803-331L 200 340 88.2/420
12565-980334/001 200 / DAMPF
08804100 650 -45 356
10LBS30AA051 EXTRACTION 3 NON-RETURN FLAP 1 12565-986132 TIN PSK046N121
FA. SEMPELL 803-333RL 600 770 3.75/229
12565-980333/005 600 / DAMPF
08300100 1400 5-45 2470
10LBS30AA052 EXTRACTION 3 NON-RETURN FLAP 2 12565-986132 TIN PSK046N411
FA. SEMPELL 803-331L 600 770 3.75/229
12565-980334/005 600 / DAMPF
MA &MPD019
Valve List
Lists
12565-980333/005 600 / DAMPF
08300100 1400 5-45 2470
10LBS31AA052 EXTRACTION 3 NON-RETURN FLAP 2 12565-986132 TIN PSK046P103
FA. SEMPELL 803-331L 600 770 3.75/229
12565-980334/005 600 / DAMPF
08304100 1400 5-45 2380
10LBS40AA051 EXTRACTION 4 NON-RETURN FLAP 1 12565-986132 TIN PSK046N125
FA. SEMPELL 803-333RL 500 700 6.8/291
12565-980333/004 500 / DAMPF
1.1.3-34100-12565 / 2-33
Technical Data
Steam Turbines
KKS Description P&I Diag. Remark
Manufacturer Type Manuf. PN Casing DN In Length In Total Heigth Des. Press./Tmp. Spindle Jointing
Supplier Drawing No. PN In DN Out1 Length Out Ambient Tmp. Op. Press./Tmp. Medium
Design Group Material Casing PN Out DN Out2 Length Tot. Differential Weight
Unit /// /// bar Diam.Cl. mm mm/C/C bar/C //Kg
10LBS50AA051 EXTRACTION 5 NON-RETURN FLAP 1 12565-986132 TIN PSK046N185
FA. SEMPELL 803-333RL 600 770 16/431
12565-980333/003 600 / DAMPF
08500100 1400 5-45 2470
10LBS50AA052 EXTRACTION 5 NON-RETURN FLAP 2 12565-986132 TIN PSK046N452
FA. SEMPELL 803-331L 600 770 16/431
12565-980334/003 600 / DAMPF
08504100 1400 5-45 2380
10MAA11AA051 MAIN STEAM EMERGENCY STOP VALVE 1 12565-931700 TURBINE MAIN STEAM STOP VALVE 1
/
/
MA &MPD019
18000100 -
10MAA11AA321 MAA11CP421 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 1
/
Valve List
Lists
/
01360000 -
10MAA11AA322 MAA11CP421 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 2
/
/
01360000 -
10MAA12AA151 MAIN STEAM CONTROL VALVE 1 12565-986132 TURBINE MAIN STEAM CONTROL VALVE 1
/
/
1.1.3-34100-12565 / 3-33
18500100 -
10MAA12AA321 MAA12CP421 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 1
/
/
01360000 -
Index: 51
0212E
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description P&I Diag. Remark
Manufacturer Type Manuf. PN Casing DN In Length In Total Heigth Des. Press./Tmp. Spindle Jointing
Supplier Drawing No. PN In DN Out1 Length Out Ambient Tmp. Op. Press./Tmp. Medium
Design Group Material Casing PN Out DN Out2 Length Tot. Differential Weight
Unit /// /// bar Diam.Cl. mm mm/C/C bar/C //Kg
10MAA12AA322 MAA12CP421 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 2
/
/
01360000 -
10MAA14AA151 MAIN STEAM OVERLOAD VALVE 12565-931715 OVERLOAD VALVE
/
/
18640500 -
10MAA14AA311 MAA14CP021 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 1 12565-931715
/
/
MA &MPD019
01360000 -
10MAA14AA312 MAA14CP021 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 2 12565-931715
/
Valve List
Lists
/
01360000 -
10MAA21AA051 MAIN STEAM EMERGENCY STOP VALVE 2 12565-931700 TURBINE MAIN STEAM STOP VALVE 2
/
/
18000200 -
10MAA21AA321 MAA21CP421 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 1
/
/
1.1.3-34100-12565 / 4-33
01360000 -
10MAA21AA322 MAA21CP421 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 2
/
/
01360000 -
Index: 51
0212E
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description P&I Diag. Remark
Manufacturer Type Manuf. PN Casing DN In Length In Total Heigth Des. Press./Tmp. Spindle Jointing
Supplier Drawing No. PN In DN Out1 Length Out Ambient Tmp. Op. Press./Tmp. Medium
Design Group Material Casing PN Out DN Out2 Length Tot. Differential Weight
Unit /// /// bar Diam.Cl. mm mm/C/C bar/C //Kg
10MAA22AA151 MAIN STEAM CONTROL VALVE 2 12565-931700 TURBINE MAIN STEAM CONTROL VALVE 2
/
/
18500200 -
10MAA22AA321 MAA22CP421 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 1
/
/
01360000 -
10MAA22AA322 MAA22CP421 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 2
/
/
MA &MPD019
01360000 -
10MAB11AA051 INTERCEPT EMERGENCY STOP VALVE 1 12565-931710 TURBINE IP STEAM STOP VALVE 1
/
Valve List
Lists
/
28000100 -
10MAB11AA321 MAB11CP421 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 1
/
/
01360000 -
10MAB11AA322 MAB11CP421 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 2
/
/
1.1.3-34100-12565 / 5-33
01360000 -
10MAB12AA151 INTERCEPT CONTROL VALVE 1 12565-931710 TURBINE IP STEAM CONTROL VALVE 1
/
/
28500100 -
Index: 51
0212E
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description P&I Diag. Remark
Manufacturer Type Manuf. PN Casing DN In Length In Total Heigth Des. Press./Tmp. Spindle Jointing
Supplier Drawing No. PN In DN Out1 Length Out Ambient Tmp. Op. Press./Tmp. Medium
Design Group Material Casing PN Out DN Out2 Length Tot. Differential Weight
Unit /// /// bar Diam.Cl. mm mm/C/C bar/C //Kg
10MAB21AA051 INTERCEPT EMERGENCY STOP VALVE 2 12565-931710 TURBINE IP STEAM STOP VALVE 2
/
/
28000200 -
10MAB21AA321 MAB21CP421 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 1
/
/
01360000 -
10MAB21AA322 MAB21CP421 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 2
/
/
MA &MPD019
01360000 -
10MAB22AA151 INTERCEPT CONTROL VALVE 2 12565-931710 TURBINE IP STEAM CONTROL VALVE 2
/
Valve List
Lists
/
28500200 -
10MAB50AA321 MAB50CP021 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 12565-986132
/
/
01360000 -
10MAC01AA051 LOW PRESSURE TURBINE EXHAUST STEAM COOLING INJECTION CON- 12565-986132 TIN PSK036K202
TROL VALVE
MUELLER-COAX MLLER-COAX / EX- 64 40 98 64/65
1.1.3-34100-12565 / 6-33
TERN. CONTROLLED
1258229 64 40 / STEAM/CONDENSAT
98641000 64 385 4-55 14
Index: 51
0212E
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description P&I Diag. Remark
Manufacturer Type Manuf. PN Casing DN In Length In Total Heigth Des. Press./Tmp. Spindle Jointing
Supplier Drawing No. PN In DN Out1 Length Out Ambient Tmp. Op. Press./Tmp. Medium
Design Group Material Casing PN Out DN Out2 Length Tot. Differential Weight
Unit /// /// bar Diam.Cl. mm mm/C/C bar/C //Kg
10MAC10AA301 MAC10CP001 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 12565-986132
/
/
01360000 -
10MAC11AA301 MAC11CP001 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 12565-986132
/
/
01360000 -
10MAC11AA302 MAC11CP002 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 12565-986132
/
/
MA &MPD019
01360000 -
10MAC11AA303 MAC11CP003 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 12565-986132
/
Valve List
Lists
/
01360000 -
10MAG10AA051 CONDENSER 1 VACUUM BREAKER CONTROL VALVE 12565-986131
CRANE FLOW VIA/RS- 200 396 2.5/130
VRSRDRSME030XXX
12565-986790/001 200 / AIR
98679000 64 -10-55 28
10MAG10AA251 CONDENSER 1 VACUUM BREAKER CONTROL VALVE DOWNSTREAM 12565-986131
ISOLATING VALVE
1.1.3-34100-12565 / 7-33
Technical Data
Steam Turbines
KKS Description P&I Diag. Remark
Manufacturer Type Manuf. PN Casing DN In Length In Total Heigth Des. Press./Tmp. Spindle Jointing
Supplier Drawing No. PN In DN Out1 Length Out Ambient Tmp. Op. Press./Tmp. Medium
Design Group Material Casing PN Out DN Out2 Length Tot. Differential Weight
Unit /// /// bar Diam.Cl. mm mm/C/C bar/C //Kg
10MAG20AA051 CONDENSER 2 VACUUM BREAKER CONTROL VALVE 12565-986131
CRANE FLOW VIA/RS- 200 396 2.5/130
VRSRDRSME030XXX
12565-986790/001 200 / AIR
98679000 64 -10-55 28
10MAG20AA251 CONDENSER 2 VACUUM BREAKER CONTROL VALVE DOWNSTREAM 12565-986131
ISOLATING VALVE
CRANE FLOW VIA/RS-ARGN7E1XXF- 200 396 2.5/130
H20200A10G1A
12565-986430/001 200 / AIR
98643000 64 -10-55 30
10MAL11AA051 MAIN STEAM CONTROL VALVE 1 UPSTREAM DRAIN VALVE 12565-985130
MA &MPD019
50 254.1/565
12565-985410/011 65 / STEAM/CONDENSAT
Valve List
Lists
98541000 5-50 260
10MAL12AA051 MAIN STEAM CONTROL VALVE 2 UPSTREAM DRAIN VALVE 12565-985130
50 254.1/565
12565-985410/011 65 / STEAM/CONDENSAT
98541000 5-50 260
10MAL14AA051 HIGH PRESSURE STEAM TURBINE CASING BALANCE PISTON DOWN- 12565-985130
STREAM DRAIN VALVE
160 40 73.2/500
12565-985410/014 160 50 / STEAM/CONDENSAT
98541000 160 5-50 170
1.1.3-34100-12565 / 8-33
Technical Data
Steam Turbines
KKS Description P&I Diag. Remark
Manufacturer Type Manuf. PN Casing DN In Length In Total Heigth Des. Press./Tmp. Spindle Jointing
Supplier Drawing No. PN In DN Out1 Length Out Ambient Tmp. Op. Press./Tmp. Medium
Design Group Material Casing PN Out DN Out2 Length Tot. Differential Weight
Unit /// /// bar Diam.Cl. mm mm/C/C bar/C //Kg
10MAL20AA051 OVERLOAD VALVE DOWNSTREAM DRAIN VALVE 12565-985130
420 50 183/517
12565-985410/020 420 65 / STEAM/CONDENSAT
98541000 420 5-50 260
10MAL22AA051 HIGH PRESSURE STEAM TURBINE CASING DRAIN VALVE 1 12565-985130
420 50 180/520
12565-985410/022 420 65 / STEAM/CONDENSAT
98541000 420 5-50 260
10MAL23AA041 INTERCEPT EMERGENCY STOP VALVE 1 UPSTREAM DRAIN STEAM 12565-985130
TRAP
GESTRA BK212-F91-S 630 25 102 62.5/593
MA &MPD019
12565-985410/001 630 25 / S
98541000 630 330 5-50 15
10MAL23AA051 INTERCEPT EMERGENCY STOP VALVE 1 UPSTREAM DRAIN VALVE 12565-985130
Valve List
Lists
250 50 62.5/593
12565-985410/023 250 65 / STEAM/CONDENSAT
98541000 250 5-50 170
10MAL24AA041 INTERCEPT EMERGENCY STOP VALVE 2 UPSTREAM DRAIN STEAM 12565-985130
TRAP
GESTRA BK212-F91-S 630 25 102 62.5/593
12565-985410/001 630 25 / S
98541000 630 330 5-50 15
10MAL24AA051 INTERCEPT EMERGENCY STOP VALVE 2 UPSTREAM DRAIN VALVE 12565-985130
1.1.3-34100-12565 / 9-33
250 50 62.5/593
12565-985410/023 250 65 / STEAM/CONDENSAT
98541000 250 5-50 170
Index: 51
0212E
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description P&I Diag. Remark
Manufacturer Type Manuf. PN Casing DN In Length In Total Heigth Des. Press./Tmp. Spindle Jointing
Supplier Drawing No. PN In DN Out1 Length Out Ambient Tmp. Op. Press./Tmp. Medium
Design Group Material Casing PN Out DN Out2 Length Tot. Differential Weight
Unit /// /// bar Diam.Cl. mm mm/C/C bar/C //Kg
10MAL25AA051 LEAK-OFF STEAM MANIFOLD DRAIN VALVE 12565-985130
160 40 5.8/420
12565-985410/025 160 50 / STEAM/CONDENSAT
98541000 160 5-50 100
10MAL26AA051 INTERCEPT CONTROL VALVE 1 UPSTREAM DRAIN VALVE 12565-985130
250 50 62.3/593
12565-985410/026 250 65 / STEAM/CONDENSAT
98541000 250 5-50 170
10MAL27AA051 INTERCEPT CONTROL VALVE 2 UPSTREAM DRAIN VALVE 12565-985130
250 50 62.3/593
12565-985410/026 250 65 / STEAM/CONDENSAT
MA &MPD019
Valve List
Lists
12565-985410/031 250 65 / STEAM/CONDENSAT
98541000 250 5-50 170
10MAL41AA051 EXTRACTION 8 NON-RETURN FLAP UPSTREAM DRAIN VALVE 12565-985130
160 50 87.2/420
12565-985410/041 160 65 / STEAM/CONDENSAT
98541000 160 5-50 170
10MAL45AA051 EXTRACTION 6 NON-RETURN FLAP UPSTREAM DRAIN VALVE 12565-985130
160 50 29.5/490
1.1.3-34100-12565 / 10-33
Technical Data
Steam Turbines
KKS Description P&I Diag. Remark
Manufacturer Type Manuf. PN Casing DN In Length In Total Heigth Des. Press./Tmp. Spindle Jointing
Supplier Drawing No. PN In DN Out1 Length Out Ambient Tmp. Op. Press./Tmp. Medium
Design Group Material Casing PN Out DN Out2 Length Tot. Differential Weight
Unit /// /// bar Diam.Cl. mm mm/C/C bar/C //Kg
10MAL51AA051 EXTRACTION 4 NON-RETURN FLAP UPSTREAM DRAIN VALVE 12565-985130
160 50 5.8/291
12565-985410/051 160 65 / STEAM/CONDENSAT
98541000 160 5-50 100
10MAL54AA051 EXTRACTION 3 NON-RETURN FLAP UPSTREAM DRAIN VALVE 12565-985130
160 80 2.8/230
12565-985410/054 160 100 / STEAM/CONDENSAT
98541000 160 5-50 150
10MAL55AA051 EXTRACTION 3 NON-RETURN FLAP UPSTREAM DRAIN VALVE 12565-985130
250 50 62.3/593
12565-985410/026 250 65 / STEAM/CONDENSAT
MA &MPD019
Valve List
Lists
12565-985410/002 160 25 / DAMPF
98541000 160 200 5-50 6
10MAL65AA051 COLD REHEAT NON-RETURN FLAP UPSTREAM DRAIN VALVE 12565-985130
160 50 68.1/393
12565-985410/065 160 65 / STEAM/CONDENSAT
98541000 160 5-50 170
10MAL81AA051 SEAL STEAM MANIFOLD DRAIN VALVE 1 12565-985130
160 25 .1/520
1.1.3-34100-12565 / 11-33
Technical Data
Steam Turbines
KKS Description P&I Diag. Remark
Manufacturer Type Manuf. PN Casing DN In Length In Total Heigth Des. Press./Tmp. Spindle Jointing
Supplier Drawing No. PN In DN Out1 Length Out Ambient Tmp. Op. Press./Tmp. Medium
Design Group Material Casing PN Out DN Out2 Length Tot. Differential Weight
Unit /// /// bar Diam.Cl. mm mm/C/C bar/C //Kg
10MAN52AA301 MAN52CP011 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 12565-986130
/
/
01360000 -
10MAN52AA302 MAN52CP012 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 12565-986130
/
/
01360000 -
10MAN52AA303 MAN52CP013 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 12565-986130
/
/
MA &MPD019
01360000 -
10MAN53AA151 INTERMEDIATE PRESSURE BYPASS STATION 1 INJECTION WATER CON- 12565-986130
TROL VALVE
Valve List
Lists
WELLAND & TUXHORN 1155 55/112
12565-980341/001 / WATER
98676100 750 5-48 1100
10MAN53AA341 MAN53CF001A FLOW MEASUREMENT SOURCE ISOLATING VALVE 1 12565-986130 PART OF FLOW MEASURING DEVICE
/
/
01360000 -
10MAN53AA342 MAN53CF001A FLOW MEASUREMENT SOURCE ISOLATING VALVE 2 12565-986130 PART OF FLOW MEASURING DEVICE
/
1.1.3-34100-12565 / 12-33
/
01360000 -
10MAN53AA343 MAN53CF001B FLOW MEASUREMENT SOURCE ISOLATING VALVE 1 12565-986130 PART OF FLOW MEASURING DEVICE
/
/
01360000 -
0212E
Index: 51
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description P&I Diag. Remark
Manufacturer Type Manuf. PN Casing DN In Length In Total Heigth Des. Press./Tmp. Spindle Jointing
Supplier Drawing No. PN In DN Out1 Length Out Ambient Tmp. Op. Press./Tmp. Medium
Design Group Material Casing PN Out DN Out2 Length Tot. Differential Weight
Unit /// /// bar Diam.Cl. mm mm/C/C bar/C //Kg
10MAN53AA344 MAN53CF001B FLOW MEASUREMENT SOURCE ISOLATING VALVE 2 12565-986130 PART OF FLOW MEASURING DEVICE
/
/
01360000 -
10MAN53AA345 MAN53CF001C FLOW MEASUREMENT SOURCE ISOLATING VALVE 1 12565-986130 PART OF FLOW MEASURING DEVICE
/
/
01360000 -
10MAN53AA346 MAN53CF001C FLOW MEASUREMENT SOURCE ISOLATING VALVE 2 12565-986130 PART OF FLOW MEASURING DEVICE
/
/
MA &MPD019
01360000 -
10MAN55AA161 INTERMEDIATE PRESSURE STEAM BYPASS STATION 2 BYPASS VALVE 12565-986130 TIN PSK048K461
Welland & Tuxhorn DN500/750 500 4254 63.5/593
Valve List
Lists
12565-980321/001 750 / DAMPF
98673000 1350 5-50 7465
10MAN55AA301 MAN55CP011 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 12565-986130
/
/
01360000 -
10MAN55AA302 MAN55CP012 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 12565-986130
/
1.1.3-34100-12565 / 13-33
/
01360000 -
10MAN55AA303 MAN55CP013 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 12565-986130
/
/
01360000 -
Index: 51
0212E
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description P&I Diag. Remark
Manufacturer Type Manuf. PN Casing DN In Length In Total Heigth Des. Press./Tmp. Spindle Jointing
Supplier Drawing No. PN In DN Out1 Length Out Ambient Tmp. Op. Press./Tmp. Medium
Design Group Material Casing PN Out DN Out2 Length Tot. Differential Weight
Unit /// /// bar Diam.Cl. mm mm/C/C bar/C //Kg
10MAN56AA151 INTERMEDIATE PRESSURE BYPASS STATION 2 INJECTION WATER CON- 12565-986130
TROL VALVE
Welland & Tuxhorn 1155 55/112
12565-980341/001 / WATER
98676300 750 5-48 1100
10MAN56AA341 MAN56CF001A FLOW MEASUREMENT SOURCE ISOLATING VALVE 1 12565-986130 PART OF FLOW MEASURING DEVICE
/
/
01360000 -
10MAN56AA342 MAN56CF001A FLOW MEASUREMENT SOURCE ISOLATING VALVE 2 12565-986130 PART OF FLOW MEASURING DEVICE
/
MA &MPD019
/
01360000 -
10MAN56AA343 MAN56CF001B FLOW MEASUREMENT SOURCE ISOLATING VALVE 1 12565-986130 PART OF FLOW MEASURING DEVICE
Valve List
Lists
/
/
01360000 -
10MAN56AA344 MAN56CF001B FLOW MEASUREMENT SOURCE ISOLATING VALVE 2 12565-986130 PART OF FLOW MEASURING DEVICE
/
/
01360000 -
10MAN56AA345 MAN56CF001C FLOW MEASUREMENT SOURCE ISOLATING VALVE 1 12565-986130 PART OF FLOW MEASURING DEVICE
/
1.1.3-34100-12565 / 14-33
/
01360000 -
10MAN56AA346 MAN56CF001C FLOW MEASUREMENT SOURCE ISOLATING VALVE 2 12565-986130 PART OF FLOW MEASURING DEVICE
/
/
01360000 -
0212E
Index: 51
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description P&I Diag. Remark
Manufacturer Type Manuf. PN Casing DN In Length In Total Heigth Des. Press./Tmp. Spindle Jointing
Supplier Drawing No. PN In DN Out1 Length Out Ambient Tmp. Op. Press./Tmp. Medium
Design Group Material Casing PN Out DN Out2 Length Tot. Differential Weight
Unit /// /// bar Diam.Cl. mm mm/C/C bar/C //Kg
10MAN91AA001 INTERMEDIATE PRESSURE STEAM BYPASS STATION 1 INJECTION WA- 12565-986130
TER PIPE VENTILATION ISOLATING VALVE
MLLER CO-AX GMBH MLLER-COAX / DIR- 40 40 105 40/100
EKT ACTING
1258239 40 40 / STEAM/CONDENSAT
98642000 40 324 -20-60 18
10MAN92AA001 INTERMEDIATE PRESSURE STEAM BYPASS STATION 2 INJECTION WA- 12565-986130
TER PIPE VENTILATION ISOLATING VALVE
MUELLER-COAX MLLER-COAX / DIR- 40 40 105 40/100
EKT ACTING
1258239 40 40 / STEAM/CONDENSAT
98642000 40 324 -20-60 18
MA &MPD019
10MAV10AA251 MAIN LUBRICATING OIL TANK RISER SPACE OUTLET GATE VALVE 12565-981136 SUPPLIED WITH OIL MODULE
/
Valve List
Lists
/
98153000 -
10MAV10AA252 MAIN LUBRICATING OIL TANK SUCTION SPACE OUTLET GATE VALVE 12565-981136 SUPPLIED WITH OIL MODULE
/
/
98153000 -
10MAV10AA255 MAIN LUBRICATING OIL TANK OIL PURIFICATION UNIT UPSTREAM GATE 12565-981136 SUPPLIED WITH OIL MODULE
VALVE
/
1.1.3-34100-12565 / 15-33
/
98153000 -
10MAV10AA258 MAIN LUBRICATING OIL TANK FILLING/DISCHARGE GATE VALVE 12565-981136 SUPPLIED WITH OIL MODULE
/
/
98153000 -
Index: 51
0212E
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description P&I Diag. Remark
Manufacturer Type Manuf. PN Casing DN In Length In Total Heigth Des. Press./Tmp. Spindle Jointing
Supplier Drawing No. PN In DN Out1 Length Out Ambient Tmp. Op. Press./Tmp. Medium
Design Group Material Casing PN Out DN Out2 Length Tot. Differential Weight
Unit /// /// bar Diam.Cl. mm mm/C/C bar/C //Kg
10MAV10AA605 MAIN LUBRICATING OIL TANK SUCTION SPACE SAMPLE POINT STOP 12565-981136 SUPPLIED WITH OIL MODULE
VALVE
/
/
98153000 -
10MAV21AA201 LUBE OIL PUMP 1 DOWNSTREAM NON-RETURN FLAP 12565-981136 SUPPLIED WITH OIL MODULE
/
/
98153000 -
10MAV21AA202 LUBE OIL PUMP 2 DOWNSTREAM NON-RETURN FLAP 12565-981136 SUPPLIED WITH OIL MODULE
/
MA &MPD019
/
98153000 -
10MAV21AA251 LUBE OIL PRESSURE ADJUSTING VALVE 12565-981136 SUPPLIED WITH OIL MODULE
Valve List
Lists
/
/
98153000 -
10MAV21AA311 MAV21CP501 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 12565-981136 SUPPLIED WITH OIL MODULE
/
/
98153000 -
10MAV21AA315 MAV21CP505 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 12565-981136 SUPPLIED WITH OIL MODULE
/
1.1.3-34100-12565 / 16-33
/
98153000 -
10MAV21AA316 MAV21CP506 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 12565-981136 SUPPLIED WITH OIL MODULE
/
/
98153000 -
0212E
Index: 51
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description P&I Diag. Remark
Manufacturer Type Manuf. PN Casing DN In Length In Total Heigth Des. Press./Tmp. Spindle Jointing
Supplier Drawing No. PN In DN Out1 Length Out Ambient Tmp. Op. Press./Tmp. Medium
Design Group Material Casing PN Out DN Out2 Length Tot. Differential Weight
Unit /// /// bar Diam.Cl. mm mm/C/C bar/C //Kg
10MAV21AA321 LUBE OIL PUMP TEST / MAV21CP001 PRESSURE MEASUREMENT 12565-981136 SUPPLIED WITH OIL MODULE
THREE-WAY VALVE
/
/
98153000 -
10MAV21AA401 LUBE OIL PUMP 1 DRAIN DOWNSTREAM STOP VALVE 12565-981136 SUPPLIED WITH OIL MODULE
/
/
98153000 -
10MAV21AA402 LUBE OIL PUMP 2 DRAIN DOWNSTREAM STOP VALVE 12565-981136 SUPPLIED WITH OIL MODULE
/
MA &MPD019
/
98153000 -
10MAV24AA201 EMERGENCY LUBE OIL PUMP DOWNSTREAM NON-RETURN FLAP 12565-981136 SUPPLIED WITH OIL MODULE
Valve List
Lists
/
/
98153000 -
10MAV24AA311 MAV24CP501 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 12565-981136 SUPPLIED WITH OIL MODULE
/
/
98153000 -
10MAV24AA401 EMERGENCY LUBE OIL PUMP DRAIN DOWNSTREAM STOP VALVE 12565-981136 SUPPLIED WITH OIL MODULE
/
1.1.3-34100-12565 / 17-33
/
98153000 -
10MAV30AA251 LIFTING OIL PUMPS FILLING STOP VALVE 12565-981136 SUPPLIED WITH OIL MODULE
/
/
98153000 -
0212E
Index: 51
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description P&I Diag. Remark
Manufacturer Type Manuf. PN Casing DN In Length In Total Heigth Des. Press./Tmp. Spindle Jointing
Supplier Drawing No. PN In DN Out1 Length Out Ambient Tmp. Op. Press./Tmp. Medium
Design Group Material Casing PN Out DN Out2 Length Tot. Differential Weight
Unit /// /// bar Diam.Cl. mm mm/C/C bar/C //Kg
10MAV31AA201 LIFTING OIL PUMP 1 DOWNSTREAM NON-RETURN VALVE 12565-981141 SUPPLIED WITH OIL MODULE
/
/
98153000 -
10MAV31AA202 LIFTING OIL PUMP 1 FILLING VALVE UPSTREAM NON-RETURN VALVE 12565-981141 SUPPLIED WITH OIL MODULE
/
/
98153000 -
10MAV31AA251 LIFTING OIL PUMP 1 DOWNSTREAM ISOLATING VALVE 12565-981141 SUPPLIED WITH OIL MODULE
/
/
MA &MPD019
98153000 -
10MAV31AA301 MAV31CP001 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 1 12565-981141 SUPPLIED WITH OIL MODULE
/
Valve List
Lists
/
98153000 -
10MAV31AA302 MAV31CP501 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 1 12565-981141 SUPPLIED WITH OIL MODULE
/
/
98153000 -
10MAV31AA311 MAV31CP001 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 2 12565-981141 SUPPLIED WITH OIL MODULE
/
1.1.3-34100-12565 / 18-33
/
98153000 -
10MAV31AA312 MAV31CP501 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 2 12565-981141 SUPPLIED WITH OIL MODULE
/
/
98153000 -
Index: 51
0212E
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description P&I Diag. Remark
Manufacturer Type Manuf. PN Casing DN In Length In Total Heigth Des. Press./Tmp. Spindle Jointing
Supplier Drawing No. PN In DN Out1 Length Out Ambient Tmp. Op. Press./Tmp. Medium
Design Group Material Casing PN Out DN Out2 Length Tot. Differential Weight
Unit /// /// bar Diam.Cl. mm mm/C/C bar/C //Kg
10MAV32AA201 LIFTING OIL PUMP 2 DOWNSTREAM NON-RETURN VALVE 12565-981141 SUPPLIED WITH OIL MODULE
/
/
98153000 -
10MAV32AA202 LIFTING OIL PUMP 2 FILLING VALVE UPSTREAM NON-RETURN VALVE 12565-981141 SUPPLIED WITH OIL MODULE
/
/
98153000 -
10MAV32AA251 LIFTING OIL PUMP 2 DOWNSTREAM ISOLATING VALVE 12565-981141 SUPPLIED WITH OIL MODULE
/
/
MA &MPD019
98153000 -
10MAV32AA301 MAV32CP001 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 1 12565-981141 SUPPLIED WITH OIL MODULE
/
Valve List
Lists
/
98153000 -
10MAV32AA302 MAV32CP501 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 1 12565-981141 SUPPLIED WITH OIL MODULE
/
/
98153000 -
10MAV32AA311 MAV32CP001 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 2 12565-981141 SUPPLIED WITH OIL MODULE
/
1.1.3-34100-12565 / 19-33
/
98153000 -
10MAV32AA312 MAV32CP501 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 2 12565-981141 SUPPLIED WITH OIL MODULE
/
/
98153000 -
Index: 51
0212E
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description P&I Diag. Remark
Manufacturer Type Manuf. PN Casing DN In Length In Total Heigth Des. Press./Tmp. Spindle Jointing
Supplier Drawing No. PN In DN Out1 Length Out Ambient Tmp. Op. Press./Tmp. Medium
Design Group Material Casing PN Out DN Out2 Length Tot. Differential Weight
Unit /// /// bar Diam.Cl. mm mm/C/C bar/C //Kg
10MAV35AA251 LIFTING OIL PRESSURE LIMITATION STATION BYPASS VALVE 12565-981141 SUPPLIED WITH OIL MODULE
/
/
98153000 -
10MAV35AA271 LIFTING OIL FILTER SELECTION THREE-WAY VALVE 12565-981141 SUPPLIED WITH OIL MODULE
/
/
98153000 -
10MAV35AA272 LIFTING OIL FILTER BALANCING LINE ISOLATING VALVE 12565-981141 SUPPLIED WITH OIL MODULE
/
/
MA &MPD019
98153000 -
10MAV35AA301 MAV35CP001 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 1 12565-981136 SUPPLIED WITH OIL MODULE
/
Valve List
Lists
/
98153000 -
10MAV35AA302 MAV35CP002 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 1 12565-981141 SUPPLIED WITH OIL MODULE
/
/
98153000 -
10MAV35AA311 MAV35CP001 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 2 12565-981136 SUPPLIED WITH OIL MODULE
/
1.1.3-34100-12565 / 20-33
/
98153000 -
10MAV35AA312 MAV35CP002 PRESSURE MEASUREMENT SOURCE ISOLATING VALVE 2 12565-981141 SUPPLIED WITH OIL MODULE
/
/
98153000 -
Index: 51
0212E
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description P&I Diag. Remark
Manufacturer Type Manuf. PN Casing DN In Length In Total Heigth Des. Press./Tmp. Spindle Jointing
Supplier Drawing No. PN In DN Out1 Length Out Ambient Tmp. Op. Press./Tmp. Medium
Design Group Material Casing PN Out DN Out2 Length Tot. Differential Weight
Unit /// /// bar Diam.Cl. mm mm/C/C bar/C //Kg
10MAV35AA401 LIFTING OIL FILTER 1 DRAIN VALVE 1 12565-981141 SUPPLIED WITH OIL MODULE
/
/
98153000 -
10MAV35AA402 LIFTING OIL FILTER 2 DRAIN VALVE 1 12565-981141 SUPPLIED WITH OIL MODULE
/
/
98153000 -
10MAV35AA411 LIFTING OIL FILTER 1 DRAIN VALVE 2 12565-981141 SUPPLIED WITH OIL MODULE
/
/
MA &MPD019
98153000 -
10MAV35AA412 LIFTING OIL FILTER 2 DRAIN VALVE 2 12565-981141 SUPPLIED WITH OIL MODULE
/
Valve List
Lists
/
98153000 -
10MAV41AA101 LUBE OIL TEMPERATURE CONTROL VALVE 12565-981136 SUPPLIED WITH OIL MODULE
/
/
98153000 -
10MAV41AA271 LUBE OIL COOLER 1 CHANGE OVER FLAP 1 12565-981136 SUPPLIED WITH OIL MODULE
/
1.1.3-34100-12565 / 21-33
/
98153000 -
10MAV41AA273 LUBE OIL COOLER 2 CHANGE OVER FLAP 1 12565-981136 SUPPLIED WITH OIL MODULE
/
/
98153000 -
Index: 51
0212E
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description P&I Diag. Remark
Manufacturer Type Manuf. PN Casing DN In Length In Total Heigth Des. Press./Tmp. Spindle Jointing
Supplier Drawing No. PN In DN Out1 Length Out Ambient Tmp. Op. Press./Tmp. Medium
Design Group Material Casing PN Out DN Out2 Length Tot. Differential Weight
Unit /// /// bar Diam.Cl. mm mm/C/C bar/C //Kg
10MAV41AA275 LUBE OIL COOLER BALANCING LINE ISOLATING VALVE 12565-981136 SUPPLIED WITH OIL MODULE
/
/
98153000 -
10MAV41AA401 LUBE OIL COOLER 1 OIL DISCHARGE STOP VALVE 12565-981136 SUPPLIED WITH OIL MODULE
/
/
98153000 -
10MAV41AA402 LUBE OIL COOLER 2 OIL DISCHARGE STOP VALVE 12565-981136 SUPPLIED WITH OIL MODULE
/
/
MA &MPD019
98153000 -
10MAV41AA501 LUBE OIL COOLER 1 OIL VENTILATION STOP VALVE 12565-981136 SUPPLIED WITH OIL MODULE
/
Valve List
Lists
/
98153000 -
10MAV41AA502 LUBE OIL COOLER 2 OIL VENTILATION STOP VALVE 12565-981136 SUPPLIED WITH OIL MODULE
/
/
98153000 -
10MAV42AA201 LUBE OIL FILTER DOWNSTREAM NON-RETURN FLAP 12565-981136 SUPPLIED WITH OIL MODULE
/
1.1.3-34100-12565 / 22-33
/
98153000 -
10MAV42AA251 STEAM TURBINE BEARING 1 UPSTREAM LUBE OIL ADJUSTING VALVE 12565-981131
PERSTA PERSTA Z.-NR. 16 20 199 13/80
E11817
1252161 16 20 / OIL
98141000 P250GH 16 180 10-60 2
0212E
Index: 51
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description P&I Diag. Remark
Manufacturer Type Manuf. PN Casing DN In Length In Total Heigth Des. Press./Tmp. Spindle Jointing
Supplier Drawing No. PN In DN Out1 Length Out Ambient Tmp. Op. Press./Tmp. Medium
Design Group Material Casing PN Out DN Out2 Length Tot. Differential Weight
Unit /// /// bar Diam.Cl. mm mm/C/C bar/C //Kg
10MAV42AA253 STEAM TURBINE BEARING 2 UPSTREAM LUBE OIL ADJUSTING VALVE 12565-981131
PERSTA PERSTA Z.-NR. 16 65 246 13/80
E11817
1252165 16 65 / OIL
98141000 P250GH 16 290 10-60 12
10MAV42AA255 STEAM TURBINE BEARING 3 UPSTREAM LUBE OIL ADJUSTING VALVE 12565-981131
PERSTA PERSTA Z.-NR. 16 40 234 13/80
E11817
1252163 16 40 / OIL
98141000 P250GH 16 210 10-60 7
10MAV42AA257 STEAM TURBINE BEARING 4 UPSTREAM LUBE OIL ADJUSTING VALVE 12565-981131
PERSTA PERSTA Z.-NR. 16 65 246 13/80
MA &MPD019
E11817
1252165 16 65 / OIL
Valve List
Lists
98141000 P250GH 16 290 10-60 12
10MAV42AA259 STEAM TURBINE BEARING 5 UPSTREAM LUBE OIL ADJUSTING VALVE 12565-981131
PERSTA PERSTA Z.-NR. 16 50 246 13/80
E11817
1252164 16 50 / OIL
98141000 P250GH 16 290 10-60 7
10MAV42AA271 STEAM TURBINE BEARING LUBE OIL FILTER 1 DOWNSTREAM CHANGE 12565-981136 SUPPLIED WITH OIL MODULE
OVER FLAP
/
1.1.3-34100-12565 / 23-33
/
98153000 -
10MAV42AA275 STEAM TURBINE BEARING LUBE OIL FILTER BALANCING LINE ISOLAT- 12565-981136 SUPPLIED WITH OIL MODULE
ING VALVE
/
/
98153000 -
0212E
Index: 51
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description P&I Diag. Remark
Manufacturer Type Manuf. PN Casing DN In Length In Total Heigth Des. Press./Tmp. Spindle Jointing
Supplier Drawing No. PN In DN Out1 Length Out Ambient Tmp. Op. Press./Tmp. Medium
Design Group Material Casing PN Out DN Out2 Length Tot. Differential Weight
Unit /// /// bar Diam.Cl. mm mm/C/C bar/C //Kg
10MAV42AA316 LUBE OIL PRESSURE MEASUREMENT MAV42CP016 SOURCE ISOLATING 12565-981136 SUPPLIED WITH OIL MODULE
VALVE
/
/
98153000 -
10MAV42AA317 LUBE OIL PRESSURE MEASUREMENT MAV42CP017 SOURCE ISOLATING 12565-981136 SUPPLIED WITH OIL MODULE
VALVE
/
/
98153000 -
10MAV42AA318 LUBE OIL PRESSURE MEASUREMENT MAV42CP018 SOURCE ISOLATING 12565-981136 SUPPLIED WITH OIL MODULE
VALVE
MA &MPD019
/
/
Valve List
Lists
98153000 -
10MAV42AA322 EMERGENCY OIL PUMP / MAV42CP012 PRESSURE TEST THREE-WAY 12565-981136 SUPPLIED WITH OIL MODULE
VALVE
/
/
98153000 -
10MAV42AA329 EMERGENCY OIL PUMP / MAV42CP019 PRESSURE TEST THREE-WAY 12565-981136 SUPPLIED WITH OIL MODULE
VALVE
/
1.1.3-34100-12565 / 24-33
/
98153000 -
10MAV42AA401 STEAM TURBINE BEARING LUBE OIL FILTER 1 DISCHARGE STOP VALVE 12565-981136 SUPPLIED WITH OIL MODULE
/
/
98153000 -
Index: 51
0212E
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description P&I Diag. Remark
Manufacturer Type Manuf. PN Casing DN In Length In Total Heigth Des. Press./Tmp. Spindle Jointing
Supplier Drawing No. PN In DN Out1 Length Out Ambient Tmp. Op. Press./Tmp. Medium
Design Group Material Casing PN Out DN Out2 Length Tot. Differential Weight
Unit /// /// bar Diam.Cl. mm mm/C/C bar/C //Kg
10MAV42AA402 STEAM TURBINE BEARING LUBE OIL FILTER 2 DISCHARGE STOP VALVE 12565-981136 SUPPLIED WITH OIL MODULE
/
/
98153000 -
10MAV42AA411 STEAM TURBINE BEARING LUBE OIL FILTER 1 DISCHARGE MAIN LUBE 12565-981136 SUPPLIED WITH OIL MODULE
OIL TANK UPSTREAM ISOLATING VALVE
/
/
98153000 -
10MAV42AA412 STEAM TURBINE BEARING LUBE OIL FILTER 2 DISCHARGE MAIN LUBE 12565-981136 SUPPLIED WITH OIL MODULE
OIL TANK UPSTREAM ISOLATING VALVE
/
MA &MPD019
/
98153000 -
Valve List
Lists
10MAV42AA501 STEAM TURBINE BEARING LUBE OIL FILTER 1 VENTILATION STOP 12565-981136 SUPPLIED WITH OIL MODULE
VALVE
/
/
98153000 -
10MAV42AA502 STEAM TURBINE BEARING LUBE OIL FILTER 2 VENTILATION STOP 12565-981136 SUPPLIED WITH OIL MODULE
VALVE
/
/
1.1.3-34100-12565 / 25-33
98153000 -
10MAV42AA605 STEAM TURBINE BEARING LUBE OIL FILTER UPSTREAM SAMPLE POINT 12565-981136 SUPPLIED WITH OIL MODULE
STOP VALVE
/
/
98153000 -
Index: 51
0212E
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description P&I Diag. Remark
Manufacturer Type Manuf. PN Casing DN In Length In Total Heigth Des. Press./Tmp. Spindle Jointing
Supplier Drawing No. PN In DN Out1 Length Out Ambient Tmp. Op. Press./Tmp. Medium
Design Group Material Casing PN Out DN Out2 Length Tot. Differential Weight
Unit /// /// bar Diam.Cl. mm mm/C/C bar/C //Kg
10MAV44AA251 GENERATOR TURBINE SIDE BEARING UPSTREAM LUBE OIL ADJUSTING 12565-981131
VALVE
PERSTA PERSTA Z.-NR. 16 40 234 13/80
E11817
1252163 16 40 / OIL
98141000 P250GH 16 210 10-60 7
10MAV44AA253 GENERATOR EXCITER SIDE BEARING UPSTREAM LUBE OIL ADJUSTING 12565-981131
VALVE
PERSTA PERSTA Z.-NR. 16 40 234 13/80
E11817
1252163 16 40 / OIL
98141000 P250GH 16 210 10-60 7
MA &MPD019
Valve List
Lists
PERSTA PERSTA Z.-NR. 16 20 199 13/80
E11817
1252161 16 20 / OIL
98141000 P250GH 16 180 10-60 2
10MAV51AA012 SHAFT TURNING GEAR MOTOR UPSTREAM 2/2-WAY SOLENOID VALVE 12565-013355 SUPPLIED WITH HYDROMOTOR VALVE
BLOCK
FLUTEC WSEV12120-04X-G24- 350 250/70
Z4
350 / OIL
11170000 350 -
1.1.3-34100-12565 / 26-33
10MAV51AA201 SHAFT TURNING GEAR MOTOR LUBE OIL NON-RETURN VALVE 12565-013355 SUPPLIED WITH HYDROMOTOR VALVE
BLOCK
FLUTEC RVE-R38-X-0.5 PN350 350 250/70
350 / OIL
11170000 350 -
Index: 51
0212E
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description P&I Diag. Remark
Manufacturer Type Manuf. PN Casing DN In Length In Total Heigth Des. Press./Tmp. Spindle Jointing
Supplier Drawing No. PN In DN Out1 Length Out Ambient Tmp. Op. Press./Tmp. Medium
Design Group Material Casing PN Out DN Out2 Length Tot. Differential Weight
Unit /// /// bar Diam.Cl. mm mm/C/C bar/C //Kg
10MAV51AA251 SHAFT TURNING GEAR MOTOR OIL ADJUSTING VALVE 12565-013355 SUPPLIED WITH HYDROMOTOR VALVE
BLOCK
FLUTEC DVP-16-01.X PN350 350 250/70
350 / OIL
11170000 350 -
10MAV66AA201 STEAM TURBINE FRONT BEARING 1 UPSTREAM LIFTING OIL NON-RE- 12565-982131 SUPPLIED WITH MAD11 BEARING VALVE
TURN VALVE BLOCK
FLUTEC RVE-R1/2-X-3 PN350 350 250/70
350 / OIL
11170000 350 -
10MAV66AA205 STEAM TURBINE FRONT BEARING 2 UPSTREAM LIFTING OIL NON-RE- 12565-982131 SUPPLIED WITH MAD12 BEARING. VALVE
TURN VALVE BLOCK
MA &MPD019
Valve List
Lists
16170000 350 -
10MAV66AA209 STEAM TURBINE FRONT BEARING 3 UPSTREAM LIFTING OIL NON-RE- 12565-982131 SUPPLIED WITH MAD13 BEARING VALVE
TURN VALVE BLOCK
FLUTEC RVE-R1/2-X-3 PN350 350 250/70
350 / OIL
26170000 350 -
10MAV66AA210 STEAM TURBINE FRONT BEARING 3 UPSTREAM LIFTING OIL NON-RE- 12565-982131 SUPPLIED WITH MAD13 BEARING VALVE
TURN VALVE 2 BLOCK
FLUTEC RVE-R1/2-X-3 PN350 350 250/70
1.1.3-34100-12565 / 27-33
350 / OIL
26170000 350 -
10MAV66AA213 STEAM TURBINE FRONT BEARING 4 UPSTREAM LIFTING OIL NON-RE- 12565-982131 SUPPLIED WITH MAD14 BEARING VALVE
TURN VALVE BLOCK
FLUTEC RVE-R1/2-X-3 PN350 350 250/70
350 / OIL
36170000 350 -
0212E
Index: 51
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description P&I Diag. Remark
Manufacturer Type Manuf. PN Casing DN In Length In Total Heigth Des. Press./Tmp. Spindle Jointing
Supplier Drawing No. PN In DN Out1 Length Out Ambient Tmp. Op. Press./Tmp. Medium
Design Group Material Casing PN Out DN Out2 Length Tot. Differential Weight
Unit /// /// bar Diam.Cl. mm mm/C/C bar/C //Kg
10MAV66AA214 STEAM TURBINE FRONT BEARING 4 UPSTREAM LIFTING OIL NON-RE- 12565-982131 SUPPLIED WITH MAD14 BEARING VALVE
TURN VALVE 2 BLOCK
FLUTEC RVE-R1/2-X-3 PN350 350 250/70
350 / OIL
36170000 350 -
10MAV66AA217 STEAM TURBINE FRONT BEARING 5 UPSTREAM LIFTING OIL NON-RE- 12565-982131 SUPPLIED WITH MAD15 BEARING VALVE
TURN VALVE BLOCK
FLUTEC RVE-R1/2-X-3 PN350 350 250/70
350 / OIL
46170000 350 -
10MAV66AA218 STEAM TURBINE FRONT BEARING 5 UPSTREAM LIFTING OIL NON-RE- 12565-982131 SUPPLIED WITH MAD15 BEARING VALVE
TURN VALVE 2 BLOCK
MA &MPD019
Valve List
Lists
46170000 350 -
10MAV66AA251 STEAM TURBINE FRONT BEARING 1 UPSTREAM LIFTING OIL ADJUSTING 12565-982131 SUPPLIED WITH MAD11 BEARING VALVE
VALVE BLOCK
FLUTEC DVP-12-01.X PN350 350 250/70
350 / OIL
11170000 350 -
10MAV66AA255 STEAM TURBINE FRONT BEARING 2 UPSTREAM LIFTING OIL ADJUSTING 12565-982131 SUPPLIED WITH MAD12 BEARING VALVE
VALVE BLOCK
FLUTEC DVP-12-01.X PN350 350 250/80
1.1.3-34100-12565 / 28-33
350 / OIL
16170000 350 -
10MAV66AA259 STEAM TURBINE FRONT BEARING 3 UPSTREAM LIFTING OIL ADJUSTING 12565-982131 SUPPLIED WITH MAD13 BEARING VALVE
VALVE BLOCK
FLUTEC DVE08-01.X/0 350 250/70
350 / OIL
26170000 350 -
0212E
Index: 51
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description P&I Diag. Remark
Manufacturer Type Manuf. PN Casing DN In Length In Total Heigth Des. Press./Tmp. Spindle Jointing
Supplier Drawing No. PN In DN Out1 Length Out Ambient Tmp. Op. Press./Tmp. Medium
Design Group Material Casing PN Out DN Out2 Length Tot. Differential Weight
Unit /// /// bar Diam.Cl. mm mm/C/C bar/C //Kg
10MAV66AA260 STEAM TURBINE FRONT BEARING 3 UPSTREAM LIFTING OIL ADJUSTING 12565-982131 SUPPLIED WITH MAD13 BEARING VALVE
VALVE 2 BLOCK
FLUTEC DVE08-01.X/0 350 250/70
350 / OIL
26170000 350 -
10MAV66AA263 STEAM TURBINE FRONT BEARING 4 UPSTREAM LIFTING OIL ADJUSTING 12565-982131 SUPPLIED WITH MAD14 BEARING VALVE
VALVE BLOCK
FLUTEC DVE08-01.X/0 350 250/70
350 / OIL
36170000 350 -
10MAV66AA264 STEAM TURBINE FRONT BEARING 4 UPSTREAM LIFTING OIL ADJUSTING 12565-982131 SUPPLIED WITH MAD14 BEARING VALVE
VALVE 2 BLOCK
MA &MPD019
Valve List
Lists
36170000 350 -
10MAV66AA267 STEAM TURBINE FRONT BEARING 5 UPSTREAM LIFTING OIL ADJUSTING 12565-982131 SUPPLIED WITH MAD15 BEARING VALVE
VALVE BLOCK
FLUTEC DVE08-01.X/0 350 250/70
350 / OIL
46170000 350 -
10MAV66AA268 STEAM TURBINE FRONT BEARING 5 UPSTREAM LIFTING OIL ADJUSTING 12565-982131 SUPPLIED WITH MAD15 BEARING VALVE
VALVE 2 BLOCK
FLUTEC DVE08-01.X/0 350 250/70
1.1.3-34100-12565 / 29-33
350 / OIL
46170000 350 -
10MAV67AA205 COLLECTOR/EXCITER BEARING UPSTREAM LIFTING OIL CHECK VALVE 12565-982131 TIN PSK045T140
ARNDT ARNDT RV25S MIT 2 315 15 /
SCHWEISSKEGELN
1250544 15 / OEL
98241000 105 -20-60
0212E
Index: 51
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description P&I Diag. Remark
Manufacturer Type Manuf. PN Casing DN In Length In Total Heigth Des. Press./Tmp. Spindle Jointing
Supplier Drawing No. PN In DN Out1 Length Out Ambient Tmp. Op. Press./Tmp. Medium
Design Group Material Casing PN Out DN Out2 Length Tot. Differential Weight
Unit /// /// bar Diam.Cl. mm mm/C/C bar/C //Kg
10MAV67AA255 COLLECTOR/EXCITER BEARING UPSTREAM LIFTING OIL ADJUSTING 12565-982131
VALVE
FLUTEC DV16-30.X/0 250 106 250/80 O-RING
1252134 / OEL
98241000 VITON 78 - 1
10MAV82AA191 OIL VAPOUR EXHAUST OIL SEPARATOR DOWNSTREAM SAFETY VALVE 12565-981136 SUPPLIED WITH OIL MODULE
/
/
98153000 -
10MAV82AA192 OIL VAPOUR EXHAUST OIL SEPARATOR UPSTREAM SAFETY VALVE 12565-981136 SUPPLIED WITH OIL MODULE
/
MA &MPD019
/
98153000 -
10MAV82AA201 OIL VAPOUR EXTRACTOR 1 DOWNSTREAM NON-RETURN FLAP 12565-981136 SUPPLIED WITH OIL MODULE
Valve List
Lists
/
/
98153000 -
10MAV82AA202 OIL VAPOUR EXTRACTOR 2 DOWNSTREAM NON-RETURN FLAP 12565-981136 SUPPLIED WITH OIL MODULE
/
/
98153000 -
10MAV82AA251 MAIN LUBE OIL TANK OIL VAPOUR EXHAUST THROTTLE VALVE 12565-981136 SUPPLIED WITH OIL MODULE
/
1.1.3-34100-12565 / 30-33
/
98153000 -
Index: 51
0212E
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description P&I Diag. Remark
Manufacturer Type Manuf. PN Casing DN In Length In Total Heigth Des. Press./Tmp. Spindle Jointing
Supplier Drawing No. PN In DN Out1 Length Out Ambient Tmp. Op. Press./Tmp. Medium
Design Group Material Casing PN Out DN Out2 Length Tot. Differential Weight
Unit /// /// bar Diam.Cl. mm mm/C/C bar/C //Kg
10MAV82AA252 OIL VAPOUR EXHAUST SUPPLEMENTARY AIR FILTER DOWNSTREAM 12565-981136 SUPPLIED WITH OIL MODULE
ISOLATION VALE
/
/
98153000 -
10MAV82AA253 MAIN OIL TANK UPSTREAM OIL SEPARATOR OIL RETURN ISOLATING 12565-981136 SUPPLIED WITH OIL MODULE
VALVE
/
/
98153000 -
10MAV82AA402 OIL VAPOR OVER ROOF PIPE DRAIN ISOLATING VALVE 12565-981136 SUPPLIED WITH OIL MODULE
/
MA &MPD019
/
98153000 -
Valve List
Lists
10MAV89AA258 LUBE OIL SYSTEM DRAIN PANS STOP VALVE 12565-981136 SUPPLIED WITH OIL MODULE
/
/
98153000 -
10MAV89AA259 LUBE OIL COOLERS DRAIN PAN STOP VALVE 12565-981136 SUPPLIED WITH OIL MODULE
/
/
98153000 -
10MAV91AA251 OIL SEPARATOR CENTRIFUGE FEED ADJUSTING VALVE 12565-981136 SUPPLIED WITH OIL MODULE
1.1.3-34100-12565 / 31-33
/
/
98153000 -
Index: 51
0212E
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description P&I Diag. Remark
Manufacturer Type Manuf. PN Casing DN In Length In Total Heigth Des. Press./Tmp. Spindle Jointing
Supplier Drawing No. PN In DN Out1 Length Out Ambient Tmp. Op. Press./Tmp. Medium
Design Group Material Casing PN Out DN Out2 Length Tot. Differential Weight
Unit /// /// bar Diam.Cl. mm mm/C/C bar/C //Kg
10MAW10AA151 SEAL STEAM SUPPLY CONTROL VALVE 12565-984131
HORA 1313-01 80 1000 15/360
12565-984514/001 250 / STEAM
98451400 775 5-50 240
10MAW10AA152 SEAL STEAM SUPPLY CONTROL VALVE BYPASS ADJUSTING VALVE 12565-984131
HORA 1313-01 80 1200 15/360
12565-984514/005 250 / STEAM
98451400 775 5-50 240
10MAW50AA151 LEAK-OFF STEAM DISCHARGE CONTROL VALVE 12565-984131
HORA 1313-01 50 350 1550 15/588
12565-984514/002 50 350 / STEAM
MA &MPD019
Valve List
Lists
HORA 1313-01 50 350 1500 15/588
12565-984514/006 50 350 / STEAM
98451400 50 980 5-50 1000
10PGB01AA401 LUBE OIL COOLER 1 COOLING WATER INLET DRAIN STOP VALVE 12565-981136 SUPPLIED WITH OIL MODULE
/
/
98153000 -
10PGB01AA402 LUBE OIL COOLER 2 COOLING WATER INLET DRAIN STOP VALVE 12565-981136 SUPPLIED WITH OIL MODULE
/
1.1.3-34100-12565 / 32-33
/
98153000 -
Index: 51
0212E
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Technical Data
Steam Turbines
KKS Description P&I Diag. Remark
Manufacturer Type Manuf. PN Casing DN In Length In Total Heigth Des. Press./Tmp. Spindle Jointing
Supplier Drawing No. PN In DN Out1 Length Out Ambient Tmp. Op. Press./Tmp. Medium
Design Group Material Casing PN Out DN Out2 Length Tot. Differential Weight
Unit /// /// bar Diam.Cl. mm mm/C/C bar/C //Kg
10PGB02AA501 LUBE OIL COOLER 1 COOLING WATER OUTLET VENTILATING STOP 12565-981136 SUPPLIED WITH OIL MODULE
VALVE
/
/
98153000 -
10PGB02AA502 LUBE OIL COOLER 2 COOLING WATER OUTLET VENTILATING STOP 12565-981136 SUPPLIED WITH OIL MODULE
VALVE
/
/
98153000 -
Index: 51
MA &MPD019
Valve List
Lists
1.1.3-34100-12565 / 33-33
0212E
Raichur Power Corporation Limited
2 X 800 MW YERAMARUS THERMAL POWER STATION
Unit 10
File Ident: MA.TP2.01
File: MA 1-4 General / Descriptions
shielding plates at turbine casing end walls Each component with a higher surface temperature then
shieldings at bearing housings and valve actuators 60 C, must be market by warning signs.
Sort of Insulation
1 spray insulation (rock wool basis) protected by a cement covering and oil-resistant coating
2 axial joint of turbine casing ( 400 C): prefabricated mats (with rockwool filling); mats are sewn into removable panels
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
6 rock wool mats with wire netting, outer alu-zinc sheet metal cover (combined heat lagging / noise absorption)
7 rock wool mats with wire netting, outer aluminium sheet metal cover (sea water proof) for combined heat lagging and
of a utility model or design, are reserved.
noise absorption
8 rock wool mats with wire netting, outer stainless steel sheet metal cover for combined heat lagging and noise absorption
9 prefabricated sewn mats (with rock wool filling) protected by alu-zinc sheet metal cover
10 prefabricated sewn mats (with rock wool filling) protected by aluminium sheet metal cover (sea water proof)
11 prefabricated sewn mats (with rock wool filling) protected by stainless steel sheet metal cover
12 insulation acc. to requirements of location with alu-zinc sheet metal cover (contact protecting; allowable surface temper-
ature 60 C)
13 insulation acc. to requirements of location with aluminium sheet metal cover (sea water proof) (contact protecting; allow-
able surface temperature 60 C)
14 insulation acc. to requirements of location with stainless steel sheet metal cover (contact protecting; allowable surface
temperature 60 C)
15 microporous insulation material for confined areas
16 microporous insulation material for confined areas with stainless steel sheet metal cover
Class: FOR INTERNAL USE ONLY
17 microporous insulation material for confined areas with aluminium sheet metal cover
18 protection against contact, without insulation
C see sh. 1 mm
H Turbine 10MAA
1 Admission Casing 566 1 240
1 Exhaust Casing 393 1 160
1 Front Side +X 2) 566 17 50-240
1 Front Side -X 2) 393 17 50-160
2 Coupling Nut Connection 3) 566 4x 100/240
2 Extraction A8 10 LBQ80 420 4 170
I Turbine 10MAB
1 Upper part IP 291 2, 11 160
1 Lower part IP 291 1 120
1 Front side +X2) 291 16 50-160
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
(removeable)
10MAA11AA051
10MAA12AA151
2 HP-valve-casing 566 1,4 240
10MAA21AA051
10MAA22AA151
10MAB11AA051
10MAB12AA151
2 IP-valve-casing 593 1,4 38/230
10MAB21AA051
10MAB22AA151
1 Overload valve Casing 10MAA14AA151 566 1,4 240
1 HP-Relief Valve 10LBC41AA051 454 4 160
1 Cold Reheat Check-Valve 10LBC10AA051 454 4 50/150
C see sh. 1 mm
Extraction Non-Return Valve A5
1 10LBS50AA051 365 4 160
with Actuator
Extraction Non-Return Valve A4
1 10LBS40AA051 260 4 100
with Actuator
Extraction Non-Return Valve A3 10LBS30AA051
2 194 4 70
with Actuator 10LBS31AA051
Extraction Non-Return Valve A8
1 10LBQ80AA052 380 4 140
without Actuator
Extraction Non-Return Valve A6
1 10LBQ60AA052 462 4 50/150
without Actuator
Extraction Non-Return Valve A5
1 10LBS50AA052 365 3 60
without Actuator
Extraction Non-Return Valve A4
1 10LBS40AA052 260 3 100
without Actuator
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
2) In the execution of the thermal insulation must be paid attention to a flawless heat dissipation
between the front side of the turbine casing and bearing casing.
An obstruction of this room beneath and above the bearing casing is not allowable.
of a utility model or design, are reserved.
Unit 10
File Ident: MA.TP2.01
File: MA 1-4 General / Descriptions
Chapter 4
Description of Components
Title Identification No. Date
Table of Contents Chapter 4 1.1.1-02004-12565 0212E
Title
Energy Sector
Steam Turbines
Siemens AG
Hydraulic Turning Gear
General User Information
MA &MAB019
Table of Contents Chapter 4
Identification No.
1.1.4-32000-00014
Date
0806E
0212E
1.1.1-02004-12565 / 2-2
Raichur Power Corporation Limited
2 X 800 MW YERAMARUS THERMAL POWER STATION
Unit 10
File Ident: MA.TP2.01
File: MA 1-4 General / Descriptions
A Steam Outlet
I Steam Inlet
D Water Drainage
Class: FOR INTERNAL USE ONLY
1 Ring
2 Strainer screen
4 Reinforcing ring
Class: FOR INTERNAL USE ONLY
1 Ring
2 Strainer screen
3 Intermediate ring
4 Reinforcing ring
5 Rod
6 Ring
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
Description
Steam Turbines
1 2 3 4 5 6 7 8 9 10 11 14 15 16 14 15 18 19
12 13 17
MA &MDB069
Main Components
1 Hydraulic Turning Gear 8 Combined Journal and Thrust Bearing 15 LP Turbine Section / Blading
2 H-Turbine Section / Front Bearing Pedestal 9 IP Turbine Section / Casing 16 LP Turbine Section / Central Bearing Pedestal
3 Journal Bearing 10 IP Turbine Section / Blading 17 Journal Bearing
4 Turbine Shaft 11 Cross Over Pipe 18 LP Turbine Section / Rear Bearing Pedestal
5 H Turbine Section / Casing 12 LP Turbine Section / Front Bearing Pedestal 19 Journal Bearing
6 H Turbine Section / Blading 13 Journal Bearing
7 H-Tubine Section / Rear Bearing Pedestal 14 LP Turbine Section / Casing
1.1.4-11110-00006 / 1-1
1003E
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2012 - All Rights Reserved
Energy Sector
Siemens AG
Description
Steam Turbines
MA &MDB069
Arrangement Drawing
1.1.4-11130-00028 / 1-1
1 HP Turbine 3 IP Turbine
2 Rear bearing pedestal of HP turbine (thrust bearing / 4 LP turbines
fixed point for rotor train)
Expansion occurring as a result of temperature changes bines rest on the aforementioned bearing housings at the lev-
in the machine must be taken into account when supporting el of the turbine centerline. Displacement of these turbines in
the turbine generator on the foundation. the axial direction as a result of thermal expansion originates
at the brackets on the rear bearing of the HP turbine. Keys
Restrained expansion can cause impermissibly high
projecting downwards beyond the turbine centerline engage
stresses in the components of the machine. The amount of
corresponding keyways in the bearing housing.
differential axial expansion between the rotor train and the
turbine casings is governed by the anchoring concept for the Displacement transverse to the turbine centerline origi-
turbine. nate at centering guides located below the turbine centerline
Handhabung: NUR FR INTERNEN GEBRAUCH
Casing expansion
The front and rear bearing housing of the HP turbine are
fixed to the foundation via anchor bolts. The HP and IP tur-
A B-B
B B B B
6 7
ihres Inhaltes nicht gestattet, soweit nicht ausdrcklich zugestanden.
Weitergabe sowie Vervielfltigung dieser Unterlage, Verwertung und Mitteilung
Detail A
insbesondere fr Fall der Patenterteilung oder GM- Eintragung.
Rotor expansion from the rear bearing housing of the HP turbine and that orig-
inating from the thrust bearing. The greatest differential ex-
The thrust bearing is installed in the rear bearing housing pansion therefore occurs in the exhaust area of the LP turbine
of the HP turbine The HP rotor expands from the thrust bear- as well as at the end of the HP turbine facing away from the
ing in the direction of the front bearing of the HP turbine. The thrust bearing.
shafts of the IP turbine and LP turbines expand from the thrust
bearing in the direction of the generator.
Differential Expansion
Differential expansion between the rotor and casings ari-
ses from the difference between the expansion originating
Handhabung: NUR FR INTERNEN GEBRAUCH
Unit 10
File Ident: MA.TP2.01
File: MA 1-4 General / Descriptions
Design and Operating Principle The two-piece outer casing is of the barrel type with a
radial flange providing a for the most part rotationally-sym-
The HP turbine is of single-flow design with a double shell metrical form avoiding the need for thicker wall sections even
comprising an inner and outer casing. It is designed with two for high steam parameters. This prevents large unsymmetri-
stop valves arranged at the side at the level of the turbine cal deformations and thermal stressing.
centerline with a flanged connection having a union nut (A-A);
additional supports are required for the valves. The inlet noz-
zles are of volute design to minimize pressure losses.
3 2
C B X W
Y A Z
1
ihres Inhaltes nicht gestattet, soweit nicht ausdrcklich zugestanden.
Weitergabe sowie Vervielfltigung dieser Unterlage, Verwertung und Mitteilung
4 R A
C B
Figure 1 Diagram of a typical HP turbine
Arrangement of Inner Casing centric with the turbine rotor. The axial fixed point for the inner
casing is illustrated in Detail (-W-) and comprises a collar on
The inner casing (4) is supported in the barrel casing inlet the inner casing which bears against a shoulder in the barrel
section (2) in the horizontal plane and is centered in the ver- casing inlet section. Axial thrust acting on the inner casing is
tical plane via four parallel keys (Section B-B). The attach- transmitted to and accommodated by the threaded ring (6).
ments are designed to allow free thermal expansion of the Axial thermal expansion of the inner casing originates at this
inner casing in all radial directions and from a fixed point in point.
the axial direction. This ensures that the inner remains con-
A-A
2 4 1 15 11 12
ihres Inhaltes nicht gestattet, soweit nicht ausdrcklich zugestanden.
Weitergabe sowie Vervielfltigung dieser Unterlage, Verwertung und Mitteilung
V
Handhabung: NUR FR INTERNEN GEBRAUCH
H
B-B
2
4
U
2 10
10
H-H
4
ihres Inhaltes nicht gestattet, soweit nicht ausdrcklich zugestanden.
Weitergabe sowie Vervielfltigung dieser Unterlage, Verwertung und Mitteilung
2
4
10
insbesondere fr Fall der Patenterteilung oder GM- Eintragung.
Copyright Siemens AG 2011 - All Rights Reserved
W
X 2
3
4
6
Y
Handhabung: NUR FR INTERNEN GEBRAUCH
Fig. 5 Saw-tooth thread ring, shoulder of inner casing with fixed point
Energy Sector
Description
Steam Turbines
Siemens AG
4 Inner casing
1 Turbine rotor
P
P
R
14
MAA &MDB069
12 Fixture
13
14 L ring seal
13 Nozzle ring
12
P-P
12
Description of Components
0711E
1.1.4-14120-00019 / 4-6
Steam Turbines Description of Components
Description HP Turbine / Casing
7
4 5
ihres Inhaltes nicht gestattet, soweit nicht ausdrcklich zugestanden.
Weitergabe sowie Vervielfltigung dieser Unterlage, Verwertung und Mitteilung
2 2
insbesondere fr Fall der Patenterteilung oder GM- Eintragung.
7 I seal ring
8 Holding ring
Fig. 7 U seal ring
9 Bolt
Exhaust
The exhaust nozzle is arranged vertically beneath the
turbine cylinder. A welded joint forms the connection to the
HP exhaust steam line.
Handhabung: NUR FR INTERNEN GEBRAUCH
Energy Sector
Description
Steam Turbines
Siemens AG
1 Turbine rotor
3 Barrel casing exhaust section
C-C
MAA &MDB069
Fig. 9 Section through exhaust
4 Inner casing
HP Turbine / Casing
4
3
Description of Components
0711E
1.1.4-14120-00019 / 6-6
Steam Turbines H Turbine
Description Casing Supports and Guides
Turbine Casing Support ing the support brackets projecting into the appropriate re-
cesses of the bearing pedestals (1;10) by bows (3;11). Clear-
When supporting the turbine casing on the bracket sup- ance S is adjusted between the sliding pieces (4;16) and the
ports and sliding pieces, thermal casing expansion is taken support brackets.
into consideration. The centric position with respect to the
turbine rotor, being supported on its own, has to be ensured.
Casing Guides
The two front and rear support brackets of the turbine
The centric position of the turbine casing transverse to
casing (2) are positioned at unit centerline level in the bracket
the unit axis is ensured by the casing guides (sections B-B
supports of the bearing pedestals (1;10). Thus, the elevation
and D-D) being formed by protrusions on the bearing pedestal
of the turbine casing is established.
and forks on the outer casing . Axial expansion of the turbine
In case of thermal expansion the casing support brackets casing is possible in these guides. Exact alignment of the
may horizontally slide on sliding pieces (5;12) integrated in casing is provided by keys (9;15).
keys (6;13). Lifting of the turbine casing is prevented by hold-
1 A-A
4
3
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
2 5
S 7
A
Copyright Siemens AG 1999 - All Rights Reserved
6
A
of a utility model or design, are reserved.
B B-B
8
B 9
5 Sliding piece
12
11
10
Energy Sector
Description
Bow
Steam Turbines
Siemens AG
Sliding piece
2
H-turbine casing
Rear bearing pedestal
C
C
S
D
16
D
10
16
15
14
13
Key
Key
Plate
11
MAA &MDB069
Sliding piece
H Turbine
14
D-D
C-C
12
15
13
0199E
1.1.4-14123-00001 / 2-2
Steam Turbines H Turbine
Description Shaft Seals and Balance Piston
Gap Sealing
Sealing between the moving and stationary parts of the
turbine is achieved by means of seal strips (8) being caulked
into the seal rings (6) and the turbine rotor (1) (Details A, B).
Copyright Siemens AG 2009 - All Rights Reserved
3 2 B
of a utility model or design, are reserved.
1
Class: FOR INTERNAL USE ONLY
Fig.1 Shaft Seals Exhaust End (A) and Admission End (B)
3
1
Energy Sector
Description
3
Steam Turbines
Siemens AG
Turbine rotor
8
7
G
T
8
7
A
H
R
Seal strip
MAA/MAW &MDB069
H Turbine
Caulked material
Fig.2 Shaft Seal Exhaust End
H
8
7
Shaft Seals and Balance Piston
0109E
1.1.4-14125-00010 / 2-3
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2009 - All Rights Reserved
2
1
Energy Sector
Description
Steam Turbines
Siemens AG
Turbine rotor
1
2
6
5
C
C
B
Seal ring
MAA/MAW &MDB069
Q
H Turbine
E
6 R
S
5
8
7
Shaft Seals and Balance Piston
Seal strip
Caulked material
0109E
1.1.4-14125-00010 / 3-3
Steam Turbines H Turbine
Description Blading
Stationary and Rotating Blades blades have inverted T-roots (2). Stationary and rotating
blades are inserted into matching slots in the inner casing or
The drum stages mounted in the inner casing or station- stationary blade carrier and shaft respectively and are
ary blade carrier and in the shaft are reaction stages with caulked in place with caulking material (4).
around 50% reaction.
3
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
6
Copyright Siemens AG 2006 - All Rights Reserved
5 5 5
of a utility model or design, are reserved.
2
2
4
Fig. 1 Arrangement of stationary and moving blades*
The insertion slots for the rotating blades are closed by screws. After assembling the complete blade ring the integral
means of a locking blade held in position by taper pins or set shrouds form a continuous shroud band which is finish ma-
chined to provide the labyrinth seal geometry.
The first stage is designed as a low-reaction stage. Here spaces between the individual sealing elements. The sealing
energy conversion is performed for the most part in the sta- elements consist of machined tips or caulked seal strips in the
tionary blade row, so that a lower temperature level already stationary and rotating components. Should faulted operating
exists downstream of the stationary blade row. The stationary conditions cause rubbing, the abradable seal strips wear
blades are supported at both ends thus preventing any tip down without causing any appreciable heatup. They can then
leakage and flow to the first row of stationary blades is im- be easily replaced at a later date (e.g. at a major inspection)
proved via a rotor shield. to restore the required clearances.
Unit 10
File Ident: MA.TP2.01
File: MA 1-4 General / Descriptions
Double Shell Design This arrangement allows free displacement of the indi-
vidual parts in all directions while maintaining a proper seal.
The casing of the IP turbine is split horizontally and is of
double-shell design. The outer casing (2, 3) houses a double-
flow inner casing (4, 5). The steam exhausted from the HP
Attachment of Inner Casing
turbine passes through two combined IP stop and control Due to the temperature differences existing between the
valves (7) (Section A-A) arranged at the side of the turbine outer casing and the inner casing, the inner casing is suppor-
and into the blading in the inlet section of the inner casing. ted in the outer casing such as to allow free thermal expansion
The exhaust nozzle in the outer casing top half routes the in the axial direction starting from an axial fixed point and in
steam from the inner casing to the inner casing of the LP tur- all radial directions, whereby concentricity with the rotor is re-
bine via the crossover line. The arrangement provides for op- tained at all times.
posing flow directions in the two blading flow sections thereby
Connections for the steam inlets are designed so as not
compensating axial thrust forces. This central admission also
to hinder thermal expansion.
prevents the high temperature of the admitted steam from
having any influence on turbine support points and bearings. As shown in Details "D" and "E" of Figure 6, in the hori-
zontal plane the inner casing top half rests with its four support
This inner casing arrangement means that only the inlet
brackets on the plates (13) lying on the joint of the outer cas-
section of the inner casing is subjected to the high tempera-
ing bottom half (3).
tures and pressures of the steam. The outer casing joint is
subjected only to the reduced pressure and temperature of Thermal expansion in the vertical direction originates
ihres Inhaltes nicht gestattet, soweit nicht ausdrcklich zugestanden.
Weitergabe sowie Vervielfltigung dieser Unterlage, Verwertung und Mitteilung
the steam at the inner casing outlet. There is therefore no from the support at the casing joint. This ensures that the in-
need for heavy flanges in the area of the casing joint and ner casing remains concentric with the rotor in this plane.
flange thickness can be kept to a minimum. This in turn avoids
The brackets provided on the inner casing bottom half
the problems resulting from deformation of a flanged-joint
insbesondere fr Fall der Patenterteilung oder GM- Eintragung.
S from the installed outer casing top half. Inner casing lift in
vailing in the outer casing counteracts the internal pressure
the outer casing is therefore limited to the clearance S.
acting on the inner casing joint so that this joint need only be
designed to accommodate the differential pressure loading. As illustrated in Detail D, fitted pieces at the casing joint
serve to fix the axial position of the inner casing at the turbine
Admission end. Thermal expansion in the axial direction originates from
these points. Radial expansion is not restrained. The support
The connections between the inlet sleeves (7) and the brackets at the generator end can move freely in the axial
inner casing (4,5) are sealed via L rings (9).. One end of the direction (Detail E).
L ring engages the collar of the threaded ring (10) and the
other end a circumferential groove in the inner casing (5). Four centering guides are arranged in the vertical plane,
two in the casing bottom half and two in the casing top half.
The threaded ring is fitted such that the short collar of the The centering guides which slide in axial grooves in the inner
L ring can slide freely between the collar of the threaded ring casing, comprise a centring bolt (16) arranged in the outer
and the bearing surface. The internal steam pressure forces casing and a sliding piece (15). The differential expansion
the seal ring against the bearing surface. The ring grooves occurring between the inner and outer casing as a result of
are provided with sufficient tolerance to allow sliding of the temperature differences is equalized in the radial and axial
Handhabung: NUR FR INTERNEN GEBRAUCH
long leg of the L ring. directions by the sliding pieces guided in the grooves of the
The L rings widen due to the internal positive pressure inner casing.
differential and their outside surfaces are pressed tightly
against the circumferential grooves to provide a seal.
4
3
2
1
Energy Sector
Description
Rotor
Steam Turbines
Siemens AG
3
1
6
8
A
8
7
6
5
MAB &MDB069
7
Bleed
Admission
Y
0909E
1.1.4-17120-00010 / 2-5
Weitergabe sowie Vervielfltigung dieser Unterlage, Verwertung und Mitteilung
ihres Inhaltes nicht gestattet, soweit nicht ausdrcklich zugestanden.
Zuwiderhandlungen verpflichten zu Schadenersatz. Alle Rechte vorbehalten,
insbesondere fr Fall der Patenterteilung oder GM- Eintragung.
Handhabung: NUR FR INTERNEN GEBRAUCH Copyright Siemens AG 2009 - All Rights Reserved
9
5
7
Energy Sector
Description
L ring seal
Admission
Steam Turbines
Siemens AG
Inner casing bottom half
5
10
9
X
A-A
Threaded ring
MAB &MDB069
Fig. 2 Admission
10
Fig. 3 Admission seal
X
Casing / IP Turbine
Description of Components
0909E
1.1.4-17120-00010 / 3-5
Weitergabe sowie Vervielfltigung dieser Unterlage, Verwertung und Mitteilung
ihres Inhaltes nicht gestattet, soweit nicht ausdrcklich zugestanden.
Zuwiderhandlungen verpflichten zu Schadenersatz. Alle Rechte vorbehalten,
insbesondere fr Fall der Patenterteilung oder GM- Eintragung.
Handhabung: NUR FR INTERNEN GEBRAUCH Copyright Siemens AG 2009 - All Rights Reserved
5
4
Energy Sector
Description
Steam Turbines
Siemens AG
Inner casing bottom half
Outer casing bottom half
D
16
Y
15 Sliding piece
Centering pin
16
MAB &MDB069
4
E
5
Fig. 5 Centering guide of inner casing
Casing / IP Turbine
15
0909E
1.1.4-17120-00010 / 4-5
Weitergabe sowie Vervielfltigung dieser Unterlage, Verwertung und Mitteilung
ihres Inhaltes nicht gestattet, soweit nicht ausdrcklich zugestanden.
Zuwiderhandlungen verpflichten zu Schadenersatz. Alle Rechte vorbehalten,
insbesondere fr Fall der Patenterteilung oder GM- Eintragung.
Handhabung: NUR FR INTERNEN GEBRAUCH Copyright Siemens AG 2009 - All Rights Reserved
4
3
11
Energy Sector
Plate
Description
Steam Turbines
12
11
Siemens AG
S
K-K
13
12
Plate
K
Fitted piece
MAB &MDB069
3
4
13
J-J
E
Description of Components
0909E
1.1.4-17120-00010 / 5-5
Steam Turbines IP Turbine
Description Casing Supports and Guides
1
2 4 9 3
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
5
A-A
Copyright Siemens AG 2002 - All Rights Reserved
of a utility model or design, are reserved.
6
S
A 7 B-B
8
B
B
Class: FOR INTERNAL USE ONLY
Casing Guides fork-type connecting elements in the outer casing. The turbine
casing is free to expand in these guides (3). Precise alignment
The central position of the turbine casing transverse to of the casing is achieved using tapered fitted keys (8, 16).
the turbine centerline is maintained by casing guides (Section
B-B, D-D) which comprise keys on the bearing pedestal and
13
C-C
11 12
3 14
10
S
C
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
D-D
15
Copyright Siemens AG 2002 - All Rights Reserved
of a utility model or design, are reserved.
C
16
A B
Copyright Siemens AG 2009 - All Rights Reserved
of a utility model or design, are reserved.
Energy Sector
Description
Steam Turbines
Siemens AG
T
10
S
A
Seal Strip
X
MAB/MAW &MDB069
Fig.2 Shaft Seal (Detail A)
10
Description of Components
Shaft Seal / IP Turbine Section
0909E
1.1.4-17125-00010 / 2-3
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved.
Class: FOR INTERNAL USE ONLY Copyright Siemens AG 2009 - All Rights Reserved
Energy Sector
Description
Steam Turbines
Siemens AG
9
W
9
Seal Strip
B
W
S
MAB/MAW &MDB069
Fig.3 Shaft Seal (Detail B)
T
Description of Components
Shaft Seal / IP Turbine Section
0909E
1.1.4-17125-00010 / 3-3
Steam Turbines Description of Components
Description IP Turbine / Blading
Stationary and Rotating Blades (1) and the moving blades have inverted T-roots (2) or double
T-roots (3). Stationary and rotating blades are inserted into
The drum stages mounted in the inner casing or station- matching slots in the inner casing or stationary blade carrier
ary blade carrier and in the shaft are reaction stages with and shaft respectively and are caulked in place with caulking
around 50% reaction. material (6).
The blades comprise the blade root, an integral shroud
(4) and airfoil (5). The stationary blades have inverted T-roots
1
4
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
5
Copyright Siemens AG 2006 - All Rights Reserved
of a utility model or design, are reserved.
2
6
The insertion slots for the rotating blades are closed by tionary blade row, so that a lower temperature level already
means of a locking blade held in position by taper pins or set exists downstream of the stationary blade row. The stationary
screws. After assembling the complete blade ring the integral blades are supported at both ends thus preventing any tip
shrouds form a continuous shroud band which is finish ma- leakage and flow to the first row of stationary blades is im-
chined to provide the labyrinth seal geometry. proved via a rotor shield.
Reducing Tip Clearances stationary and rotating components. Should faulted operating
conditions cause rubbing, the abradable seal strips wear
To reduce blade tip losses, sealing geometries are used down without causing any appreciable heatup. They can then
which cause optimum turbulence in the leakage flow in the be easily replaced at a later date (e.g. at a major inspection)
spaces between the individual sealing elements. The sealing to restore the required clearances.
elements consist of machined tips or caulked seal strips in the
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
Unit 10
File Ident: MA.TP2.01
File: MA 1-4 General / Descriptions
Valve Arrangement
Steam Path into the stationary blade carrier of the HP turbine. The volume
of steam enclosed in the space between the control valve and
The steam admitted through the admission line (1) pass- the HP turbine is small owing to the short connecting line,
es through the stop valve to the control valve. A short turbine which has a favorable influence on shutdown reliability.
inlet nozzle routes the steam from the control valve to the tur-
bine casing. The steam passesthrough the inlet nozzle (7)
5 5
3 3
4 4
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
6 6
2
of a utility model or design, are reserved.
7 7
1 1
Class: FOR INTERNAL USE ONLY
Steam Path The volume of steam enclosed in the space between the
control valves and the IP turbine is small owing to the short
The steam admitted through the admission line (1) pass- connecting line, which has a favorable influence on shutdown
es through the stop valves (3) to the control valves (4). The reliability.
control valves are flanged to the turbine casing. The steam
leaves the control valve passing through the inlet nozzle (7)
into the inner casing of the IP turbine section (2).
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
Task and Arrangement the valve is open and provides additional sealing at this point.
Metal bushes (9) seal the valve stem (4). The stop valve is
One stop and one control valve are combined in a com- opened by the hydraulic actuator (12) and closed by spring
mon body. The emergency stop valve serves as the primary force.
shutoff valve between the steam supply system and the tur-
bine and can halt the supply of steam to the turbine within a
very short time.
Control Valve
The control valve with plug-type disk has a single-piece
The control valve controls the steam flow to the turbine
stem which slides in the guide bushing. Balancing holes in the
according to the prevailing load.
valve plug reduce the actuating force required This valve disk
also has a back seat which is effective when the valve is fully
Stop Valve opened. Both the stem and disk are secured against rotation.
The stop valve is a single seat valve with integral pilot Packing rings and bushes (17) seal the valve stem (14)
disk. Steam enters the valve body (1) with steam strainer (5) in the valve bonnet (16). The control valve is actuated by the
via the inlet connection and is applied to the valve disk (3) piston of the actuator (20) with actuation in the closing direc-
when the stop valve is closed. A pilot disk integral with the tion via spring force and in the opening direction by hydraulic
valve stem (4) is incorporated in the valve disk to relieve the force.
steam pressure on the valve disk and thus reduce the force
required to open the valve. There is a bead on the back of the In the event of a disturbance in the system or on turbine
ihres Inhaltes nicht gestattet, soweit nicht ausdrcklich zugestanden.
Weitergabe sowie Vervielfltigung dieser Unterlage, Verwertung und Mitteilung
valve disk which lies against the backseat bushing (6) when trip both stop valve and control valve close.
Legend to figure
Stop Valve Control Valve
insbesondere fr Fall der Patenterteilung oder GM- Eintragung.
Energy Sector
Description
Steam Turbines
Siemens AG
20
18
11
19
9
17
16
15
MAA &MDB069
Stop and Control Valves
Main Valves
14
13
Combined Main Steam Stop and Control Valve
2
3
4
5
6
8
7
1
9
10
12
0809E
1.1.4-16010-00102 / 2-2
Steam Turbines Description of Components
Description Overload Valve
Function the valve disk reduce the operating force required. Also this
disk is provided with a back seat which becomes effective
The overload valve is a single control valve that operates when the valve is fully open.
when the main steam control valves are full open (at rated
load). It controls additional steam flow into the HP turbine to Packing rings seal the valve stem in the valve cover. The
provide extra load above the rated machine output. control valve is operated by the piston of the actuator (3), i.e.
the valve is opened hydraulically and closed by spring force.
Therefore steam from the main steam valves enters the
overload valve via the inlet connections (1) and leaves it via In the event of a disturbance in the system, or on turbine
the outlet connections (2). trip, all stop valves and control valves close rapidly.
Description
The one part stem of the control valve with tubular valve
disk, slides in the bushing of the valve cover. Vent holes in
2
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
3
Copyright Siemens AG 2011 - All Rights Reserved
of a utility model or design, are reserved.
Overload Valve
Function and Design holes in the valve disk reduce the actuating force required to
open the valve. This valve disk also has a back seat which is
One stop and one control valve are combined in a com- effective when the valve is fully opened. Packing rings seal
mon body. The IP stop valve is designed to rapidly interrupt the valve stem in the valve bonnet. The control valve is op-
the supply of steam from the hot reheat piping. It is designed erated by the piston of the actuator; the valve is opened hy-
to provide the shortest possible closing times with maximum draulically and closed by spring force. In the event of a dis-
reliability. The IP control valve controls the steam flow to the turbance in the system or on turbine trip both stop valve and
turbine according to the prevailing load. The design principle control valve close rapidly.
of the combined IP stop and control valve assembly allows
easy maintenance.
Integral Steam Strainers
Stop Valve Steam strainers integrated in the valve body prevent for-
eign particles from entering the steam turbine admission and
The stop valve is a single seat valve with integral pilot the blading. The strainers also serve to optimize the steam
disk. Steam enters the valve body with steam strainer via the flow and thereby avoid pressure losses in the valves.
inlet connection and remains above the valve disk when the
stop valve is closed. A pilot disk integral with the valve stem
is incorporated in the valve disk to relieve the steam pressure
Valve Actuators
on the disk and thus reduce the force required to open the The stop valve and the control valve each have a dedi-
valve. There is a sealing surface on the back of the valve disk cated electrohydraulic actuator which move the valve stem
ihres Inhaltes nicht gestattet, soweit nicht ausdrcklich zugestanden.
Weitergabe sowie Vervielfltigung dieser Unterlage, Verwertung und Mitteilung
which lies against the base bushing (6) when the valve is open against the spring force. The valves are closed fail-safe by
and provides additional sealing at this point. Graphite packing the spring force in the event of a power failure. The stop valve
rings seal the valve stem off against the atmosphere. A stem actuators and control valve actuators are arranged above op-
insbesondere fr Fall der Patenterteilung oder GM- Eintragung.
leakoff is also provided on the stop valve. The stop valve is erating floor level so that they are easily accessible for main-
opened by the hydraulic actuator and closed by spring force. tenance.
Copyright Siemens AG 2009 - All Rights Reserved
Energy Sector
Description
Steam Turbines
Siemens AG
18
9
17
16
19
L2
15
MAB &MDB069
14 13
Main Valves
2
4
3
8
1
7
6
5
11
10
Combined Reheat Steam Stop and Control Valve
0309E
1.1.4-20510-00100 / 2-2
Raichur Power Corporation Limited
2 X 800 MW YERAMARUS THERMAL POWER STATION
Unit 10
File Ident: MA.TP2.01
File: MA 1-4 General / Descriptions
2
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
7
Copyright Siemens AG 2009 - All Rights Reserved
of a utility model or design, are reserved.
Fig. 1 LP turbine
( shows a typical arrangement )
inlet nozzles in the casing top section. Expansion joints allow to pressure thereby reducing exhaust losses. The steam then
thermal expansion of the casing in the direction of flow. flows into the condenser located below.
Energy Sector
Description
Steam Turbines
1 Turbine rotor
Siemens AG
Z
6
A
MAC &MDB069
Casing
L Turbine
0109E
1.1.4-21120-00027 / 2-7
Steam Turbines L Turbine
Description Casing
Z
5
7
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
Outer Casing verse to the turbine centerline originate from the centering
guides located beneath the turbine centerline between the
The welded outer casing comprises the top and bottom condenser and foundation slab. Axial displacements originate
sections. from the fixed anchor points for the condenser which are lo-
Outer casing, bottom section: This comprises two end- cated in the area of the front bearing pedestal of the LP tur-
wall bottom sections, two side walls and a stiffener. The com- bine. Vertical expansion towards the turbine centerline origi-
ponents are welded together. nates from the supports on the foundation slab. The displace-
ment differential between the outer casing and the bearing
Outer casing top section: Two end wall sections welded pedestals is accommodated by expansion joints at the sup-
to a single unit form the outer casing top section. port arms and at the shaft seal casings and the crossover
Class: FOR INTERNAL USE ONLY
The top section is bolted to the end walls and the side piping.
walls of the bottom section. Changes to alignment due to foundation displacements
The outer casing is supported on the condenser, to which can be accommodated by placing shims beneath the con-
it is welded. Casing expansion therefore also originates from denser. Hydraulic jacks are placed between the condenser
the condenser guides and supports. Displacements trans- and the foundation slab to lift the condenser.
X
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
13
13
3
Copyright Siemens AG 2009 - All Rights Reserved
of a utility model or design, are reserved.
Inner casing Four integrally-cast support lugs on the inner casing bot-
tom section rest on the bearing pedestals. The support points
The cast inner casing is of single-shell design. It has a in the pedestals are provided with self-lubricating sliding
double flow configuration and is equipped with stationary plates to reduce friction forces. The sliding plates and turbine
blade rings attached to the inner casing bottom section such expansion joints allow thermal movements between the cas-
as to allow thermal expansion. The inner casing is equipped ing and the bearing pedestals. This ensures that no forces are
Class: FOR INTERNAL USE ONLY
with drum blading, the stationary blade rings with the LP sta- transferred between the inner casing and the outer casing.
tionary blade stage group.
B-B
C
9 C-C
13
11
10
C
12
7
10 Sliding plate
of a utility model or design, are reserved.
D D-D
D 15,10
20 14 7 23 6
Class: FOR INTERNAL USE ONLY
19
16
11
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
E
of a utility model or design, are reserved.
E-E
E
17 8 18
11 9
Class: FOR INTERNAL USE ONLY
Fig. 7 Connection between the upstream turbine cylinder and the inner casing of the LP turbine
cylinder
To allow axial movement of the inner casing, this con- dictates the axial position of the inner casing and ensures that
nection is provided with fitted keys and self-lubricating slide the casings expand in unison. This means that thermal ex-
plates. Expansion joints provide the requisite seal and allow pansion of both rotor and casing originate from the bearing
thermal expansion between the inner and outer casing. pedestal of the upstream turbine cylinder (combined journal
and thrust bearing), which results in small axial clearances in
The turbine end support arms are connected to the outer
the drum blading due to reduced differential expansion.
casing of the upstream turbine cylinder via push rods (8)
which pass through the front bearing housing (Fig. 5). This
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
Design
The casings of the LP turbine cylinders are of identical
design. The only difference between the first LP cylinder and
the following ones is the connection between the inner cas-
ings, and the blade path.
1 2 5 4 3
ihres Inhaltes nicht gestattet, soweit nicht ausdrcklich zugestanden.
Weitergabe sowie Vervielfltigung dieser Unterlage, Verwertung und Mitteilung
6
Copyright Siemens AG 2009 - All Rights Reserved
Shell of inner casing Sliding plates between the support points in the bearing
pedestals and the support arms reduce friction. This coupling
The inner casing is supported at four points on the bear- concept means that thermal expansion of both rotor and cas-
ing pedestals via support arms. ing originate at the front bearing pedestal of the first turbine
The TE and GE support arms are connected to the adja- cylinder (combined journal/thrust bearing).
cent LP turbine via push rods which penetrate the intermedi-
ate bearing housing. This fixes the axial position of the inner
casing and provides for cumulative thermal expansion of the
turbine casings which results in small axial clearances.
Handhabung: RESTRIKTIV
(-x) (+x)
1
R Q Q R
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
2
Copyright Siemens AG 2003 - All Rights Reserved
A
of a utility model or design, are reserved.
3
4
Drum Stages the moving blades inverted T-roots (2). Stationary and rotat-
ing blades are inserted into matching slots in the inner casing
The drum stages mounted in the inner casing or station- or stationary blade carrier and shaft respectively and are
ary blade carrier and in the shaft are reaction stages with caulked in place with caulking material (4).
around 50 % reaction.
3 1
5
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
6
Copyright Siemens AG 2006 - All Rights Reserved
of a utility model or design, are reserved.
2 4 3
Fig. 1 Arrangement of stationary and moving blades*
The insertion slots for the rotating blades are closed by LP Stages
means of a locking blade held in position by taper pins or set
screws. After assembling the complete blade ring the integral The LP blading comprises three reaction stages. The sta-
Class: FOR INTERNAL USE ONLY
shrouds form a continuous shroud band which is finish ma- tionary and rotating blades in these stages have tapered and
chined to provide the labyrinth seal geometry. twisted profiles to account for the considerable difference in
circumferential speed at the hub and tip.
To improve steam flow and reduce tip losses, a rotor
shield (shield ring, 6) has been arranged in the inlet area be- The split stationary blade rings are manufactured by
tween the shrouds of the first rows of stationary blades in the welding together the inner rings (7), blades (8) and outer rings
turbine-end and generator-end flow sections. (9) into half rings which are then attached to the inner casing.
After assembly of the complete ring the inner rings form a
continuous shroud band.
If there is a risk of water droplet erosion in the last-stage as in the drum stages. The last two rows of rotating blades
rotating blades, the hollow last-stage stationary blades (10) are designed with fir-tree roots (13) which are inserted in axial
can be provided with: slots in the turbine shaft and secured by caulking pieces. They
are secured against axial movement by retaining strip seg-
(a) drain slots, which allow extraction of the condensate
ments the end segments of which are welded at the joint.
film forming on the stationary blade airfoils in the condenser,
or Blade tip losses are minimized using a seal geometry as
described under the section Reducing tip clearances.
(b) heating, in which case, the condensate film forming
on the stationary blade airfoils is evaporated, thus preventing The last row of LP rotating blades is provided with free-
the formation of large water droplets. standing blades.
9
Copyright Siemens AG 2006 - All Rights Reserved
12
14
of a utility model or design, are reserved.
12
10 9
8
12
11 7 13
Fig. 2 LP stages, arrangement of stationary and moving blades*
Reducing tip clearances elements consist of machined tips or caulked seal strips in the
stationary and rotating components. Should faulted operating
To reduce blade tip losses, sealing geometries are used conditions cause rubbing, the abradable seal strips wear
which cause optimum turbulence in the leakage flow in the
spaces between the individual sealing elements. The sealing
Energy Sector
Description
Steam Turbines
Siemens AG
to restore the required clearances.
be easily replaced at a later date (e.g. at a major inspection)
down without causing any appreciable heatup. They can then
MAC &MDB069
Blading
L Turbine
1006E
1.1.4-21130-00020 / 3-3
Raichur Power Corporation Limited
2 X 800 MW YERAMARUS THERMAL POWER STATION
Unit 10
File Ident: MA.TP2.01
File: MA 1-4 General / Descriptions
wards, which can occur through extreme unbalance, are a rod mounted directly into the foundation which engages with
transmitted from the bearing shell through fitted blocks to the the L turbine inner casing.
pedestal cover and then via directly adjacent anchor bolts to
the foundation. Horizontal forces, transverse or axial, are In all turbines, after alignment, the position is fixed using
Copyright Siemens AG 2007 - All Rights Reserved
transmitted via the bearing shell to the pedestal via trunnions fitted keys. The centre guide permits free movement of the
on the bearing shell and fitted blocks. turbine casings due to thermal expansion in the vertical and
axial directions.
of a utility model or design, are reserved.
and at low running speeds, and to reduce starting torque, the support the turbine from the pedestals.
rotors are lifted by introducing high-pressure oil into the area
between the bottom of the journal and the bearing. For the L turbine, these supports are on the turbine inner
casing, the outer casing being supported independently of the
The H bearings are mounted on spherical seats, and the pedestals.
L bearings on spherical blocks mounted in cylindrical shells,
within the pedestals. This allows self-alignment of the bear- The supports are free to slide in the horizontal plane to
ings to accommodate rotor deflection. accommodate thermal expansion. To keep friction forces to
a minimum, the bearing area of the support arms rests on
slide plates provided with a dry-lubricant facing. Shims under
the slide plates are provided for alignment at the level of the
SST-6000 series
Energy Sector
Description
other forces.
Steam Turbines
Siemens AG
turbine axis, and keeps are provided over the support arms
to prevent the turbine from lifting due to the effect of torque or
MAD &MDB069
Design
Bearings
Turbine Bearings
0107E
1.1.4-30200-00002 / 2-2
Steam Turbines Bearings
Description H Turbine Section / Front Bearing Pedestal
1 3 4 5
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
7 6
Energy Sector
Description
Steam Turbines
Siemens AG
8 Anchor bolts
A
MAD &MDB069
Bearings
0909E
1.1.4-30410-00006 / 2-2
Steam Turbines Bearings
Description H Turbine Section / Rear Bearing Pedestal
A
5
Copyright Siemens AG 2009 - All Rights Reserved
4
6
of a utility model or design, are reserved.
3 7
2
8
A
Class: FOR INTERNAL USE ONLY
Energy Sector
Description
10
Steam Turbines
Siemens AG
1 Bearing pedestal - lower section
5 Bearing pedestal - upper section
A-A
MAD &MDB069
5
Bearings
10 Anchor bolt
1
0509E
1.1.4-30485-00008 / 2-2
Steam Turbines Bearings
Description L Turbine Section / Front Bearing Pedestal
A
3 2 5 4
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
A
Class: FOR INTERNAL USE ONLY
Energy Sector
Description
Steam Turbines
6 Foundation
Siemens AG
1 Bearing pedestal
Z
7
8
8
7
A-A
Grout
MAD &MDB069
Anchor bolt
Bearings
6
Fig. 2 Cross section through bearing pedestal
0711E
1.1.4-30520-00008 / 2-2
Steam Turbines Bearing
Description Intermediate Bearing Pedestal
SST-5000, SST-6000 series L Turbine
Arrangement lowing alignment the space between the bearing pedestal (1)
and the foundation (6) is filled with shrink-free grout (7). Ver-
The bearing is arranged in the middle between two L tur- tical forces are transmitted to the foundation via anchor bolts
bine cylinders. It serves to support the casing and carry the (8). Horizontal forces are transmitted into the foundation via
turbine rotor. keys beneath the bearing pedestal which engage corre-
The bearing pedestal contains the following components: sponding recesses in the foundation. The space between the
keys and the foundation (6) is also filled with shrink-free grout.
Journal bearing (2)
Relative vibration pickup
A
2 5 4
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
3
of a utility model or design, are reserved.
A
Class: FOR INTERNAL USE ONLY
Energy Sector
Description
Steam Turbines
6 Foundation
Siemens AG
1 Bearing pedestal
6
Z
8
7
Z
A-A
Grout
MAD &MDB069
L Turbine
Anchor bolt
Bearing
7
1
8
Fig. 2 Cross section through bearing pedestal
0308E
1.1.4-30540-00006 / 2-2
Steam Turbines Bearings
Description L Turbine Section / Rear Bearing Pedestal
SST-5000, SST-6000 series
Arrangement lowing alignment the space between the bearing pedestal (1)
and the foundation (6) is filled with shrink-free grout (7). Ver-
The bearing pedestal is arranged at the rear end of the tical forces are transmitted to the foundation via anchor bolts
last turbine section. The bearing holds the turbine rotor and (8). Horizontal forces are transmitted into the foundation via
supports the casing of the turbine section. keys beneath the bearing pedestal which engage corre-
The bearing pedestal contains the following components: sponding recesses in the foundation. The space between the
keys and the foundation (6) is also filled with shrink-free grout.
Journal bearing (2)
Relative vibration pickup
A
3 2 5 4
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
1
Class: FOR INTERNAL USE ONLY
Energy Sector
Description
Steam Turbines
6 Foundation
Siemens AG
1 Bearing pedestal
6
Z
8
7
Z
A-A
Grout
MAD &MDB069
Anchor bolt
Bearings
7
1
8
Fig. 2 Cross section through bearing pedestal
0308E
1.1.4-30560-00015 / 2-2
Steam Turbines Bearings
Description Combined Journal and Thrust Bearing
The upper and lower halves of the bearing shell are fixed Forces transverse to the unit axis and axial forces are
in position by taper pins and bolted together. transferred to the bearing pedestal and to the foundation via
bosses at the bearing body and keys (14; 15).
The bearing liner is provided with a babbitt face.
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
Fig. 1 Longitudinal and Cross Section of the Combined Journal and Thrust Bearing
Temperature Measurement tial ducts in the bearing upper section. Part of the oil leaves
Copyright Siemens AG 2007 - All Rights Reserved
Jacking Oil Sealing rings (21) located between the bearing liner (5)
and the lower bearing shell prevent any oil from penetrating.
of a utility model or design, are reserved.
5 Bearing liner
21 Sealing ring
A A-A
1
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
6
Copyright Siemens AG 2010 - All Rights Reserved
3
of a utility model or design, are reserved.
C
B 7
4
B 8
9
10
5 C
11
A
Fig. 1 Section through journal bearing
B-B C-C
12
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
4
Copyright Siemens AG 2010 - All Rights Reserved
Function Construction
The manual turning gear serves for manual turning of the The manual turning gear consists of a gearing and pawl
line of shafting. It can be used both to start the turbine-gen- (6). The pawl engages the gearing to turn the shaft system
erator unit rolling and to turn the shaft system through a given when operated by means of a bar attached to the lever (1).
angle. The pawl (6) is shown disengaged and the lever (1) resting
against the stop. The lever is held in this position by the latch
Manual operation of the turning gear may be done only
(7) when not in use.
after the shaft system has been lifted with jacking oil. If man-
ual rotation of the shaft is difficult, this may be due to incorrect
adjustment of the shaft jacking oil system or to a rubbing shaft.
In this case, corrective action must be taken before steam is
admitted to the turbine.
1 A-A
A 7
2
3
4
5
8
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
6
9
Copyright Siemens AG 2010 - All Rights Reserved
10
of a utility model or design, are reserved.
1 Lever 6 Pawl
2 Cover 7 Latch
3 Gasket 8 Pin
4 Flange 9 Pin
5 Bearing pedestal 10 Turbine rotor
Class: FOR INTERNAL USE ONLY
Function are floated for a short period through the introduction of high-
pressure feed oil from below which is supplied from the jack-
The function of the hydraulic turning gear is to rotate the ing oil system.
line of shafting at sufficient speed before startup and after
shutdown in order to avoid non-uniform heatup or cooldown
and the associated distortion of the turbine rotor.
Arrangement
The hydraulic turning gear is situated on the front of the
To overcome the initial breakaway torque on startup and
front bearing pedestal of the first turbine section.
to prevent semi-fluid lubrication, the turbine bearing journals
2 6 10 8
1 11
The reproduction, transmission or use of this document or its content is not
permitted without express written authority. Offenders will be liable for
damages. All rights, including rights created by patent grant or registration
13
12
Copyright Siemens AG 2006 - All Rights Reserved
4 5 9
of a utility model or design, are reserved.
14
7
Mode of operation and create a form fit between the outer and inner race. The
entire shaft train is then driven by the Hydraulic Motor (1),
The Hydraulic Motor (1) is connected to the bearing ped- profiled shaft (2), engaging flange (5), overrunning clutch (10)
Class: FOR INTERNAL USE ONLY
estal (7) via mounting flange (4) , housing (8) and cover (14). and output shaft (13).
The rotation of the hydraulic motor is transmitted to the outer
ring of the overrunning clutch (10) via the profiled shaft (2) When the turbine is run up these sprags move outwards
and the engaging flange (5). The outer ring is held in the cas- thereby disconnecting the clutch. At high speeds the sprags
ing by the holding ring (9) and the ball bearing (6). The inner lift off the outer race completely through centrifugal force so
ring of the overrunning clutch (10) is mounted directly on the that no wear occurs to the outer race during turbine operation.
end of the shaft (13).
3 15
of a utility model or design, are reserved.
The oil for the hydraulic turning gear is supplied from the Protecting the turning gear bearings
jacking oil system.
During turbine operation the bearings for the Hydraulic
The turning gear is switched on via an electromagnetic Motor and the clutch must be protected against standing cor-
valve. Turning gear speed is governed by a manually-adjust- rosion damage.
able throttle in the feed line to the hydraulic motor. Possible
alignment faults and any rubbing of the rotor have a detri- Following shutdown of the hydraulic jacking oil supply the
mental effect on the operation of the turning gear. Re-align- hydraulic motor is lubricated and turned using low-pressure
ment must be performed following such events. oil (approx. 2 bar) from the lube oil system.
Class: FOR INTERNAL USE ONLY
Oil is extracted from the Hydraulic Motor (1) via the inter-
nal oil drain and routed to the bearing (11) and overrunning
clutch (10) for lubrication purposes. Oil discharged from the
hydraulic motor is routed to the bearing pedestal via the return
line (15).