Types of Tests / Properties Measured /
Materials / Products Tested Standard Specifications / Techniques Used
Range of Measurements
- Static watt-hour meters of accuracy classes 1 and 2 AC Voltage Test IEC 62052-11:2003 AC/DC Voltammeter
- Static watt-hour meters of accuracy classes 0.2 S IEC 62053-21:2003 SN. 080
IEC 62053-22:2003
and 0.5S IEC 62053-23:2003
- Static Var-hour meters of accuracy classes 2 and 3 IEC 62053-11:2003
- Electromechanical watt-hour meters of accuracy EN 50470-1:2006
classes 0.5,1 and 2 EN 50470-3:2006
Power Consumption test IEC 62052- 11 :2003 Single Phase reference standard
IEC 62053- 21 :2003 Power Meter
SN. K 2071106
IEC 62053- 22 :2003 Three Phase reference standard
IEC 62053- 23 :2003 Power Meter
IEC 62053- 11 :2003 SN. 0712315
Multimeter
EN 50470-1:2006 SN. RB8936
EN 50470-3:2006 Stationary reference standard
SN. 38777
- Influence of Self-Heating IEC 62052- 11 :2003 Single Phase reference standard
IEC 62053- 21 :2003 Power Meter
- Test of Starting and no-load Condition IEC 62053- 22 :2003 S.N.: K 2071106
IEC 62053- 23 :2003 Three Phase reference standard
- Limits of error due to influence quantities IEC 62053- 11 :2003 Power Meter
- voltage variation EN 50470-1:2006 SN. 0712315
EN 50470-3:2006 Stationary reference standard
- frequency variation SN. 38777
- reversed phase sequence
- voltage unbalance
- Harmonic components in the current and
voltage circuits
- Odd harmonics in the AC current circuit
- Sub-harmonics in the AC current circuit
- Accuracy Requirements:-
- Limits of error due to variation of the
current
- Meter Constant
. .. 4102 / 9 / 7 :
Schedule of Accreditation
Polytechnique Metrology Centre (PMC)
6th October City, Industrial Zone 2, Giza- Egypt
Schedule No.: 209020B Issue No. (3): September 18, 2014 Valid to : August 22, 2018
Types of Tests / Properties Measured /
Materials / Products Tested Standard Specifications / Techniques Used
Range of Measurements
- Ambient Temperature Variation IEC 62052- 11 :2003 Single Phase Phase reference
IEC 62053- 21 :2003 standard Power Meter
- Climatic Conditions :- IEC 62053- 22 :2003 SN. K 2071106
Three Phase reference standard
- Dry Heat Test IEC 62053- 23 :2003 Power Meter
- Cold Test IEC 62053- 11 :2003 SN. 0712315
- Damp Heat Cyclic Test IEC 60068-2-30:2005 Climatic Chamber
EN 50470-1:2006 SNs. 86881537, 86881530
EN 50470-3:2006 Stationary reference standard
SN. 38777
. .. 4102 / 9 / 7 :
Schedule of Accreditation
Polytechnique Metrology Centre (PMC)
6th October City, Industrial Zone 2, Giza- Egypt
Schedule No.: 209020B Issue No. (3): September 18, 2014 Valid to : August 22, 2018
Types of Tests / Properties Measured
Materials / Products Tested Standard Specifications / Techniques Used
/ Range of Measurements
- Static watt-hour meters of accuracy classes 1 and Heating IEC 62052- 11 :2003 Single Phase reference standard
2 IEC 62053- 21 :2003 Power Meter
- Static watt-hour meters of accuracy classes 0.2 S IEC 62053- 22 :2003 SN.K 2071106
and 0.5S IEC 62053- 23 :2003 Three Phase reference standard
- Static Var-hour meters of accuracy classes 2 and 3 IEC 62053- 11 :2003 Power Meter
- Electromechanical watt-hour meters of accuracy EN 50470-1:2006 SN. 0712315
classes 0.5, 1 and 2 EN 50470-3:2006 Climatic Chamber
SNs.: 86881537, 86881530
Temperature Measuring Instrument
with Digital Indicator
S.N.:91320287
Stationary reference standard
SN. 38777
Immunity to earth fault IEC 62052- 11 :2003 Three Phase reference standard
IEC 62053- 21 :2003 Power Meter
IEC 62053- 22 :2003 S.N.: 0712315
IEC 62053- 23 :2003 Stationary reference standard
IEC 62053- 11 :2003 SN. 38777
EN 50470-1:2006
EN 50470-3:2006
Electromagnetic compatibility
- Household appliances and similar apparatus Conducted emission test 9 kHz 30 MHz IEC 62052-11:2003 Artificial mains network
- Electric tools CISPR 14-1:2011 SN. 100259
- Electric & electronic toys and similar apparatus CISPR 15:2013 Test receiver
- Electrical lighting and similar equipment CISPR 22:2008 SN. 101001
- Electricity energy meters Radiated disturbances 30 MHz 3 GHz IEC 61000-6-3:2011 GTEM
- Residential, commercial and light industrial test IEC 62052-11:2003 Model: GTEM-1000
environments CISPR 14-1:2011 Test receiver
CISPR 15: 2013 SN. 101001
CISPR 22:2008
. .. 4102 / 9 / 7 :
Schedule of Accreditation
Polytechnique Metrology Centre (PMC)
6th October City, Industrial Zone 2, Giza- Egypt
Schedule No.: 209020B Issue No. (3): September 18, 2014 Valid to : August 22, 2018
. .. 4102 / 9 / 7 :
Schedule of Accreditation
Polytechnique Metrology Centre (PMC)
6th October City, Industrial Zone 2, Giza- Egypt
Schedule No.: 209020B Issue No. (3): September 18, 2014 Valid to : August 22, 2018
Schedule of Accreditation
Polytechnique Metrology Centre (PMC)
6th October City, Industrial Zone 2, Giza- Egypt
Schedule No.: 209020B Issue No. (3): September 18, 2014 Valid to : August 22, 2018