You are on page 1of 2

DESIGN CRITERIA

MATERIALS

Concrete

Fc= 20.70 MPa

Wood : Narra 80 % Grading

Fb = 18.0 Mpa

E = 5.94 x 103 Mpa

Fv = 1.91 Mpa

Gs = 0.52

PRELIMINARY SIZES OF BEAMS AND COLUMNS

Beams : 250 mm by 300mm (10x12)

Columns : 300mm by 300mm (12x12)

DEAD LOAD:

Slab Thickness = 100 mm


Floor Finishes:

Hardwood Flooring (22mm) = 0.19 kPa

Floor wood-joist (50mm x 150mm) at spacing 600 mm Gypsum Board (per mm thickness) = 0.008
kPa

Ceramic tile (20mm) on 13 mm mortar bed = 0.77 kPa

Partition:

Interior

Wood Studs 50x100, plastered two side = 0.96 kPa

Exterior

50x150mm at 400 mm, 15 mm gypsum, insulated, 10 mm siding = 0.517 kPa


Roof:

Wood shingles = 0.14 kPa

LIVE LOAD:

Residential = 1.90 kPa

Storage = 1.90 kPa

EARTHQUAKE LOAD:

Occupancy Category: Standard Occupancy

Exposure : B

Importance Factor: IV, Standard Occupancy Structures = 1.00

Soil Profile Type: SD, Stiff soil

Kd : Building

WIND LOAD

Zone : 2

V = 200 kph

Kd=0.85

Standard Occupancy = 1.00