Anjni Transformers & Switchgears


G-99 & G-3, Phase-I, UPSIDC, Khichra
Industrial Area, Masuri-Gulawati Road,
Ghaziabad 201015, UP, India
ENERGIZING YOUR FUTURE POWER

We are glad to introduce ourselves as one of the leading manufacturer of


measuring and Protection in High Voltage and Extra High Voltage Systems
(Current Transformers and Potential Transformer) upto the System voltage of
33KV.

OVERVIEW

ANJNI TRANSFORMER & SWITCHGEARS, founded by Er. DINESH KUMAR


GOEL and Mr. SHOKAUT Ali, supported by a dedicated team of Engineers,
Technicians and Business people, committed to a Technology, best quality
products, has been in the field of Power Sector for more than 30 Years and
now established a Setup of Manufacturing state of High Voltage Power
Products, since 2005, and as we have already told above that both Mr.
Sharafat Ali, Technic al Professional having more than 24 years of experience
in Power Sector especially Instrument Transformers Category. We have very
good contacts with almost all EPC Contractors/Electrical Contractors/ PSU
Units/ Boards/Nigams. Every time, We will developed a strong clientele
by supplying high quality product to varying specifications.

APPROVALS

We are Approved in Himachal, UPCL, UJVNL PTCUL, DVVNL, HPSEB.

KINDLY NOTE THAT OUR 11KV/22KV/33KV CTs/PTs/COMBINED


CTPT UNIT HAVE BEEN APPROVED WITH HPSEB.

Apart from Manufacturing CTs/PTs upto 33KV, we are also engaged in HEAVY
FABRICATION ON TURNKEY BASIS AS PER DRAWING(S) viz. STEEL
STRUCTURES.

FACTORY SET UP

ANJNI TRANSFORMER & SWITCHGEARS has factory setup with well-


equipped laboratories, testing department with all facilities for production
check for raw material, semi-finished product and final product.

Carpet area of the factory is 4500 Sq. feet and office area 500 sq. feet at G-99
& Fabrication of CTs/PTs Tanks covered area is 5000Sq. feet and
400Sq. feet tools & Scrap area.
ENERGIZING YOUR FUTURE POWER
MOTTO

Quality, customer satisfaction and regular improvement for better to best Quality
Products.

COMMITTED TO

Design, develop, manufacture and service quality products as per


customer requirement.
Carry out production as per the standard procedures.
Improvement in product and service

As mentioned earlier, ANJNI TRANSFORMER & SWITCHGEARS is one among


those organizations in India that provides total power solution forms under a single
roof: The products and the corresponding range follows:

MANUFACTURING OF INTRUMENT TRANSFORMERS UPTO 33KV

Sr. DESCRIPTION OF ITEMS MANUFACURED RANGE


No
1 RESIN CAST CT RING TYPE & T A P E W O U N D C T 440V/660V
2 3 PHASE PTs Up to 33kV
3 Single Phase Resin Cast GUN Type PTs 33KV
4 RESIN CAST CT Up to 33kV
5 RESIN CAST PT Up to 33kV
6 COMBINED CTPT METERING SET (33kV, 22kV, 11kV) Up to 33 kV
7 OUTDOOR, SINGLE PHASE CURRENT Up to 33 Kv
TRANSFORMERS
8. OUTDOOR, SINGLE PHASE POTENTIAL Up to 33 kV
TRANSFORMERS
9. Pilfer Resistance CTPT Metering Cubicle Upto 33KV
10. Cycloaliphatic Outdoor Epoxy Cast CTs & PTs Uptp 33KV
11. Bus Duct CTs 440V
12. Resin Cast Residual Voltage Transformers Upto 33KV

TYPE TEST

Our all Products are type tested from Govt. Laboratory ERDA, Vadodara.
ENERGIZING YOUR FUTURE POWER

MANUFACTURING OF SMC (Sheet Moulding Compound) Distribution Boxes

Sr. DESCRIPTION OF ITEMS MANUFACURED


No
1 Single Phase SMC LTDB for AB Cable
2 1-Phase / 3-Phase SMC Meter Boxes for Energy Meters
3 Three Phase SMC LTDB for AB Cable
4 3-Phase SMC type Tri-Vector Meter Box
5 1-Phase SMC LTDB for 10KVA Transformer with MCCB
6 1-Phase SMC LTDB for 16KVA Transformer with MCCB
7 1-Phase SMC LTDB for 25KVA Transformer with MCCB
8. 1-Phase SMC LTDB for 63KVA Transformer with MCCB
9. 1-Phase SMC LTDB for 100KVA Transformer with MCCB
10. 1-Phase SMC LTDB for 200KVA Transformer with MCCB
11. 1-Phase SMC LTDB for 400KVA Transformer with MCCB
12. SMC type LTDB with 2 sets of 100A Fuses connected on 300A
Aluminium Bus-bar (FP Kit-Kat)
13. SMC type 3-Phase 4-Wire LTCT Metering Cubicle alongwith 4sets
of CTs Ratio 100/5A for metering of 25KVA & 63KVA
Transformer
14. SMC type 3-Phase 4-Wire LTCT Metering Cubicle alongwith 4sets
of CTs Ratio 200/5A for metering of 100KVA Transformer
15 SMC type 3-Phase 4-Wire LTCT Metering Cubicle alongwith 4sets
of CTs Ratio 400/5A for metering of 200KVA Transformer
16 SMC type 3-Phase 4-Wire LTCT Metering Cubicle alongwith 4sets
of CTs Ratio 600/5A for metering of 400KVA Transformer
ENERGIZING YOUR FUTURE POWER

DISTRIBUTION BOARDS

Apart from Manufacturing Instrument Transformers upto 33KV, Anjni Transformer &
Switchgears is engaged in inhouse Fabrication CT/PT Tanks upto 220KV &
Manufacturing of SMC (Sheet Moulded Compound) DISTRIBUTION BOARDS

1. Complete inhouse Fabrication of CTs & PTs tanks upto 220KV as per drawings.

2. LT DISTRIBUTION BOXES, 25KVA to 315KVA with Kitkat fuse as per drawing in


SMC type

3. LTCT Metering Cubicle of any Ratio, class & burden

4. Transformer Protection Boxes 10KVA/16KVA/25KVA/63KVA/100KVA/200KVA/


400KVA with MCCB as per drawing

5. Single Phase SMC Distribution Box for LT Pole 1.1 kV with clamp, Nuts & Bolts
ENERGIZING YOUR FUTURE POWER

6. Three Phase SMC Distribution Box with clamp, Nuts & Bolts

7. LT Distribution Box with MCCB for protection of 16 KVA T/F and Bus Bar for 10No.
outgoing consumer connections and suitable to house Energy meter (without
Energy meter)
LIST OF PLANT AND MACHINERY

Name Of
Sr. No. Brief Specification Qty
Machine/Equipment
Drying Oven Temp.150 deg at
1 Coil Drying Oven 1 No
atmospheric pressure

Vertical drilling Machine with3/4


2 Drilling Machine 2 Nos
Capacity

Industrial storage plastic bins &


3 Storage Bins & Racks 3 Nos
M.S.Racks to stores material

4 Axial winding machine with maximum


H.V.Coil winding machine
250 mm & axial Width 300mm Suitable 2 Nos
(Motorized)
L .V. Coil winding Axial winding machine with maximum
5 machine (Motorized) 250 mm & axial Width 300mm Suitable 2 Nos
Upto 22 swg Copper wire

Axial winding machine with maximum


H.V.Coil winding machine
6 100mm & axial Width 120mm Suitable 2 Nos
(Hand winding)
Upto 42 swg Copper wire

Bench voice 12jaw opening bench voice 2 Nos


7

8 Hand drill machine 10 mm bore capacity 2 Nos

9 2 phase, capacity of 250 mm weld


Welding transformer 2 Nos
current
Various tools for general purpose allen
10 Tooling Kit keys, spanner sets 4 Sets

Brazing unit 150 Amp brazing Current 1 No


11

1 No
12
Air compressor For painting and finishing of work
Suitable For Fabrication Bending Of
13 Bending Machine 2 Nos
Sheet Metal Of Thickness 5 Mm

Suitable For Fabrication Cutting Of


14 Shearing Machine 2 Nos
Sheet Metal Of Thickness 5 Mm

15 Grinding Machine For De Baring Of Metal Fabrication 3 Nos

16 Welding Machine Welding Of Ms Metal Purpose 4 Nos

17 Oven Heating Purpose 2 Nos

1 No
Furnace Annealing of Core
18
LIST OF EQUIPMENTS FOR TESTING (INCLUDING INSPECTION OF
RAW M ATERI ALS)

Name Of Calibration
Sr. No. Brief Specification Qty
Machine/Equipment status
Combined Digital CTPT CTPT Digital Analyzer
1 Test System for Precision for CT Ratio upto 3200A of calibrated 1 Set
accuracy upto 0.005
measurement of ratio and
phase angle error PT for 0 to 207.5VA with printer
facility
Combined CT Test System
2 Test system consisting Of test set calibrated
for measurement of ratio 1 Set
CT TEST BRIDGE FOR 5A & 1A
and phase angle error
Burden Box Of 40 VA Of 5 A
Burden Box calibrated 1 Set
Burden Box 40 VA Of 1 A
3
0-5-10-15-20-25-30-40-50-60- 75-
calibrated 1 Set
80-100-125-150-200/5 AMP
Standard CT
4 0-5-10-15-20-25-30-40-50-60- 75-
1 Set
80-100-125-150-200/1 AMP
Combined PT Test System
Test system consisting Of test set calibrated
for measurement of ratio 1 Set
5 PT Test Bridge
and phase angle error
Burden Box Of 105 VA Capacity calibrated
Of Output 110 Volts 1 Set
6 Burden Box For PT
Burden Box Of 105 VA Capacity calibrated
Of Output 63.5 Volts 1 Set

Standard 11kV PT 1 /2
6 Ratio: 11kV / 110V and 11Kv / rt3 1 Set
/110V /rt3
7 Standard 22Kv PT 1 /2 calibrated
Standard PTs Ratio: 22Kv / 110V and 22Kv / rt3 1 Set
/110V /rt3
Standard 33Kv PT 1 /2 calibrated
Ratio: 33Kv / 110V and 33Kv / rt3 1 Set
/110V /rt3
Coupled motors with panel having calibrated
High frequency generator frequency
1 Set
8 set with control panel meter to get double voltage and
frequency for testing of PTs
Test system consisting of HV test calibrated
9 transformer 80kv, 4kVA
High voltage AC Test
continuous, control desk panel 1 Set
System
with Ammeter, kV meter, and
tripping circuit of 20mA
Test system consisting of 0-5 kV calibrated
5 kV High voltage AC Test
High voltage Transformer, 1 Set
10 System.
Manual voltage regulator
Portable type precision type calibrated
voltmeter
11 Set Of Voltmeter RANGE: COM 75-150-300 VOLTS 4 Nos
RANGE; COM-150-300-600
VOLTS
Portable type precision type calibrated
voltmeter
12 Set Of Ammeter RANGE: COM-5A-10A-25A-50A- 4 Nos
100A
RANGE: COM-500ma- 1A 5A
LIST OF EQUIPMENTS FOR TESTING (INCLUDING INSPECTION OF
RAW MATERIALS)
Name Of Calibration
Sr. No. Brief Specification Qty
Machine/Equipment status
calibrated
220V/0-1500 amps with suitable
12 Current Source 1 Set
taps and capacity of 3.5 kVA

4 Terminal Milli ohmmeter fr om calibrated


Resistance Measuring
13 199.9 micro ohm to 19.9 kilo 1 No
Bridge
Ohms
calibrated
14 Polarity Meter General Purpose Analog Meter 3 Nos

0-415n Volts output calibrated


15 Voltage Regulator 28A. Auto Transfor mer 2 Nos
input 415 volts 3 PHASE
General Purpose Analog calibrated
16 Continuity Meter 1 No
Multimeter
General purpose Multimeter with calibrated
Digital General purpose facilities of AC DC voltage
17 2 Nos
Multimeter measurement, Ammeters
Resistance Measurement
5 kV MEGGER to measure calibrated
18 Megger Meter 2 Nos
insulation resistance value
Clip On Meter calibrated
19 0 1000 Amp, 750 Volts 1 No
MAKE MECO
QUALITY SYSTEMS AND PROCEDURES

1. BROUGHT OUT ITEMS (RAW M ATERI ALS)


1.1. COPPER
- Maintaining Test Report for purchase from standard manufacturers
- Testing class of insulation of enamel covering by performing temperature test
- Electrical Breakdown Value (BDV) Test of enamel cov ering
- Maintaining records of each spool used for individual job
1.2. PAPER
- Maintaining Test Report for purchase from standard manufacturers
- Testing class of insulation by carrying temperature test
- Electrical Breakdown Value (BDV) Test
1.3. OIL
- Maintaining Test Report for purchase from standard manufacturers
- Electrical Breakdown Value (BDV) Test
1.4. CORE
- Maintaining Test Report for purchase from standard manufacturers
- Verifying the grade of material
- Checking of Knee Point Voltage (SATURATION OF CORE)

2. IN HOUSE TEST (SEMI FINISHED & FINISHED GOODS)


2.1. COIL
- Resistance Of Coil
- Maintaining records of coil used for each job
- Examining dimensional records of coil
- Maintaining records of wo rker, responsible for the winding
2.2. SEMI FINISHED & FINISHED GOODS
- Maintaining test report of SEMI FINISHED & FINISHED GOODS
- Analyzing the reports of failures in inter mediate stages and taking corrective measures accordingly
- Analyzing the reports of failures in final stage and taking corrective measures accordingly
- Examining the final reports before dispatch

3. EQUIPMENTS
3.1. TEST EQUIPMENT & MACHINE RIES
- Periodically calibrating and reconditioning of test equipment and machineries from standard
government and private lab s, required for testing in the production process.
3.2. PERIODICAL MAINTENANCE OF PLANT AND MACHINE RIES

4. TESTS
4.1. TYPE TEST
- Timely performing the typ e test of the manufactured product in N.A.B.L accribated labs like E.R.D.A
(Electronic Research and Development Association) and C.P.R.I (Central Power and Research
Institute).
PRODUCT PROFILE

CURRENT TRANSFORMER

Our all the Epoxy Resin Cast Instrument Transformers & Epoxy Cast Components are
Manufactured through Automatic Machine.

APPLICATION Direct measurement of current in high voltage & high current system is not possible because of
difficulty in electrical isolation of measuring instruments. Because of its high value,it is also not possible to use current flowing
directly to the system, so that current transformer are used to step down the high system current into low system measuring
current with their proportionate ratio. due to this it is possible to measure high system current by using standard measuring
instruments & relays, also its isolate meters,relays from high voltage systems.

VARIOUS TYPES OF CURRENT TRANSFORMERS


Ring T ype Current Transformers : A Current Transformer which has an window
in the center to accommodate a primary conductor (busbar or cable) through it.

Bar -Primar y Current Transformers : A Current Transformer in which the


primary winding consists of bar of suitable size and it is an integral part of the CT.

Wound T ype Current Transformers : A Current Transformer having a primary


winding of more than one full turn wound on the core.

Interposing Current Transformers : These Current Transformers are used in


conjunction with main CTs to alter the ratio of main CT or to provide isolation to
meters or relays from main CTs secondary circuit. Primary current of these CTs
are generally lower than 1 0 amp. Due to which they are always wound primary
type.

Summation Current Transformers : W hen current flowing, in more than one


feeder is required to be metered summation current transformer are used. These
Current Transformers are provided with more than one primary winding and one
common secondary.

Bushing T ype or Busduct Current Transformers : These Current


Transformers are Ring type construction & can be mounted on Busduct or
Bushing turrert of power transformer.

Core Balance Current Transformers : These are ring type Current


Transformers & suitable for the measurement of the sum of three phase currents
in a 3-ph cable. Under normal operating conditions this sum is zero. In the event
of an earth-fault the sum of the current is equal to the zero sequence current.

.
RESIN CAST CURRENT TRANSFORMER

RANGE 11, 22 & 33 KV


ACCURACY CLASS 0.2 & 0.5
SPECIAL ACCURACY CLASS 0.2S & 0.5S
IS : 2705

Technical Specification As Per IS : 2705


General Particulars 11KV 22KV 33 KV
Highest S ystem Voltage( H.S.V.) 12 KV ( r.m.s.) 24 KV ( r.m.s.) 36 KV (r.m.s.)
Power frequency dr y/ wet withstand
voltage on primar y winding for one 28 KV ( r.m.s.) 50 KV ( r.m.s.) 70 KV ( r.m.s.)
minute
Lightning Impulse withstand voltage 75 KV ( r.m.s.) 125 KV ( r.m.s.) 170 KV ( r.m.s.)
(1.2 x 50 s )
PD measuring Voltage / Permissible 7.6/50 15.2/50 23.0/50
Voltage
Specific Particulars
Rated Transformation Ratio As per customer requirement (in Amp.)
Rated Primary Current Upto 2000 Amp.
Rated Secondary Current 1 Amp. 5 Amp. 0.577 Amp.
As per customer requirement.
Short Time Thermal Current (Ith) In general CT is to be specified with STF of 100 for 1 Sec.
or STC (lth) equal to the system fault level whichever is
lower. KA ( r.m.s. )
Short Time Dynamic Current 2.5 X Ith KA (Peak)
Number of Cores Upto 3 cores
Output Burden Upto 60VA, 0.8 pf Lagging
For Metering :
Accuracy Class 0.2S, 0.2, 0.5S, 0.5, 1.0 & 3.00.
For Protection:
5P, 10P, 15P & PS
IAF, ALF, Knee Point Voltage, As per customer requirement / Design Constraints
Exciting Current & Resistance
Type of construction As Per Panel Conditions(Customer Requirement)
OIL COOLED CURRENT TRANSFORMER

Technical Specification As Per IS : 2705


General Particulars 11KV 22KV 33 KV 66 KV
Highest S ystem 12 KV ( r.m.s.) 24 KV ( r.m.s.) 36 KV (r.m.s.) 72 KV (r.m.s.)
Voltage( H.S.V.)
Power frequency dr y/
wet withstand voltage 28 KV ( r.m.s.) 50 KV ( r.m.s.) 70 KV ( r.m.s.) 150 KV ( r.m.s.)
on primary winding
for one minute
Lightning Impulse
withstand voltage (1.2 75 KV ( r.m.s.) 125 KV ( r.m.s.) 170 KV ( r.m.s.) 350 KV ( r.m.s.)
x 50 s )
Specific Particulars
Rated Transformation As per customer requirement (in Amp.)
Ratio
Rated Primary Current Upto 2000 Amp.
Rated Secondary 1 Amp. 5 Amp. 0.577 Amp.
Current
Short Time Thermal As per customer requirement.
Current (Ith) In general CT is to be specified with STF of 100 for 1 Sec. or STC (lth) equal
to the system fault level whichever is lower. KA ( r.m.s. )
Short Time Dynamic 2.5 X Ith KA (Peak)
Current
Number of Cores Upto 5 cores
Output Burden Upto 60VA, 0.8 pf Lagging
For Metering :
Accuracy Class 0.2S, 0.2, 0.5S, 0.5, 1.0 & 3.00.
For Protection:
5P, 10P, 15P & PS
IAF, ALF, Knee Point
Voltage, Exciting As per customer requirement / Design Constraints
Current & Resistance
Type of construction Dead / Bottom Tank or Live / Top Tank
POTENTIAL TRANSFORMER

APPLICATION Direct measurement of voltage in high voltage & high current system is not possible because of

difficulty in electrical isolation of measuring instruments. Because of its high value, it is also not possible to use voltage
directly to the system, so that Potential transformer are used to step down the high system voltage into low system
measuring voltage with their proportionate ratio. due to this it is possible to measure high system voltage by using
standard measuring instruments & relays, also its isolate meters, relays from high voltage systems and also to sense
abnormalities in voltage & give signal to protective relay to isolate the defective system.

RESIN CAST POTENTIAL TRANSFORMER

RANGE 11, 22 & 33 KV


ACCURACY CLASS 0.2 & 0.5
SPECIAL ACCURACY CLASS 0.2S & 0.5S
IS : 3156

Technical Specification As Per IS : 3156

General Particulars 11KV 22KV 33 KV


Highest S ystem Voltage( H.S.V.) 12 KV ( r.m.s.) 24 KV ( r.m.s.) 36 KV (r.m.s.)
Power frequency dr y/ wet withstand
voltage on primar y winding for one 28 KV ( r.m.s.) 50 KV ( r.m.s.) 70 KV ( r.m.s.)
minute
Lightning Impulse withstand Voltage ( 75 KV ( r.m.s.) 125 KV ( r.m.s.) 170 KV ( r.m.s.)
1.2 x 50 s )
PD measuring Voltage / Permissible 7.6/50 15.2/50 23.0/50
Voltage
Specific Particulars
Number of Phases 3 or 1 unearthed or earthed
Rated Transformation Voltage Ratio As per customer requirement
Number of Secondary W indings Upto 3
Output Burden Upto 100VA
Accuracy Class For Metering : 0.2, 0.5 & 1.0
For Protection: 3P, 6P
Voltage Factor 1.2 Continuous & 1.5 for 30 Sec or 1.9 for 30 Sec or 1.9 for
8 hours
0IL COOLED POTENTIAL TRANSFORMER

OIL COOLED POTENTIAL TRANSFORMERS

Technical Specification As Per IS : 3156

General Particulars 11KV 22KV 33 KV 66 KV


Highest S ystem
12 KV ( r.m.s.) 24 KV ( r.m.s.) 36 KV (r.m.s.) 72 KV (r.m.s.)
Voltage( H.S.V.)
Power frequency
dry/ wet withstand
voltage on primar y 28 KV ( r.m.s.) 50 KV ( r.m.s.) 70 KV ( r.m.s.) 150 KV ( r.m.s.)
winding for one
minute
Lightning Impulse
withstand Voltage ( 75 KV ( r.m.s.) 125 KV ( r.m.s.) 170 KV ( r.m.s.) 350 KV ( r.m.s.)
1.2 x 50 s )
Specific Particulars
Number of Phases 3 or 1 unearthed or earthed
Rated
Transformation As per customer requirement
Voltage Ratio
Number of Upto 3
Secondary Windings
Output Burden Upto 500VA
Accuracy Class For Metering : 0.2, 0.5,1.0 & 3.0
For Protection: 3P, 6P
Voltage Factor 1.2 Continuous & 1.5 for 30 Sec or 1.9 for 30 Sec or 1.9 for 8 hours
COMBINED CTPT SET

APPLICATION- Combined CTPT Metering Units that are available up to 33 kV class are manufactured specifically to
meet the needs of Electricity Supply and captive generating units. The C.T.-P.T. metering sets of this type as the name
suggests are used for measurement of power on high voltage side. The C.T.-P.T. sets are installed before the main
transformer and the main line goes through C.T.-P.T. set to the main transformer. Metering equipment is connected to the
secondary side of the C.T.-P.T. set. As the accuracy of the C.T.-P.T. set is high & as it is connected before the transformer,
measurement of power is much more accurate compared to the metering done on L.T. side, the transformer losses are
also included in the measurement.

OIL COOLED CTPT SET RESIN CAST 3 PT

Technical Specification For Oil Cooled CTPT Set As Per IS:2705 & IS:3156

General Particulars 11KV 22KV 33 KV


Highest S ystem Voltage( H.S.V.) 12 KV ( r.m.s.) 24 KV ( r.m.s.) 36 KV (r.m.s.)
Power frequency dr y/ wet withstand
voltage on primar y winding for one 28 KV ( r.m.s.) 50 KV ( r.m.s.) 70 KV ( r.m.s.)
minute
Lightning Impulse withstand Voltage ( 75 KV ( r.m.s.) 125 KV ( r.m.s.) 170 KV ( r.m.s.)
1.2 x 50 s )
System Particulars
3 Phase 4 Wire with Isolated / Floating 3 Nos. CTs & 1 No. 3 - Phase PT
neutral as well as solidly earthed.
3 Phase 4 Wire with Isolated / Floating 2 Nos. CTs & 1 No. 3 - Phase PT
neutral as well as solidly earthed.
Specific Particulars
Short Time Thermal Current (Ith) As per customer requirement.
In general CT is to be specified with STF of 100 for 1 Sec.
or STC (lth) equal to the system fault level whichever is
lower. KA ( r.m.s. )
Output 10 VA to 100 VA for PT and 5 VA to 30 VA for CT
Accuracy Class 0.2S, 0.2, 0.5S, 0.5, 1.0 for CT. and 0.2, 0.5 & 1.0 for PT
Secondary Current (CT) 1 Amp or 5 Amp
Secondary Voltage (VT) 110 Ph-Ph or 110/v3 V, Ph-Neutral
Primary Current (CT) As per customer requirement.
Primary Voltage (VT) 11KV, 22KV, 33KV for 3-Phase PT
11/v3, 22/v3, 33/v3 for 1-Phase PT
Technical Specification For resin cast CTPT Set As Per IS:2705 & IS:3156

General Particulars 11KV 22KV 33 KV


Highest S ystem Voltage( H.S.V.) 12 KV ( r.m.s.) 24 KV ( r.m.s.) 36 KV (r.m.s.)
Power frequency dr y/ wet withstand
voltage on primar y winding for one 28 KV ( r.m.s.) 50 KV ( r.m.s.) 70 KV ( r.m.s.)
minute
Lightning Impulse withstand Voltage 75 KV ( r.m.s.) 125 KV ( r.m.s.) 170 KV ( r.m.s.)
( 1.2 x 50 s )
PD measuring Voltage / Permissible 7.6/50 15.2/50 23.0/50
Voltage
System Particulars
3 Phase 4 Wire with Isolated / Floating 3 Nos. CTs & 1 No. 3 - Phase PT
neutral as well as solidly earthed. 3 Nos. CTs & 3 Nos. 1 - Phase PT
3 Phase 4 Wire with Isolated / Floating 2 Nos. CTs & 1 No. 3 - Phase PT
neutral as well as solidly earthed. 2 Nos. CTs & 3 Nos. 1 - Phase PT
Specific Particulars
Short Time Thermal Current (Ith) As per customer requirement.
In general CT is to be specified with STF of 100 for 1 Sec.
or STC (lth) equal to the system fault level whichever is
lower. KA ( r.m.s. )
Output 10 VA to 100 VA for PT
5 VA to 30 VA for CT
Accuracy Class 0.2S, 0.2, 0.5S, 0.5, 1.0 for CT.
0.2, 0.5 & 1.0 for PT
Secondary Current (CT) 1 Amp or 5 Amp
Secondary Voltage (VT) 110 Ph-Ph or 110/v3 V, Ph-Neutral
Primary Current (CT) As per customer requirement.
Primary Voltage (VT) 11KV, 22KV, 33KV for 3-Phase PT
11/v3, 22/v3, 33/v3 for 1-Phase PT
Low Tension Pilfer Resistant Metering Cubicle

Types:- L.T to 33 KV Voltages Class


1/2/3 one to Five core available
Various outline Size as per Customer requirement
Bar and W ound primary Type
Features:- Compact in design, Low cost and maintenance free.
Used mainly for outdoor LT metering on poles.
Separate Meter compartment and CT compartment.
CT's are epoxy molded to avoid any pilferage.
CT's are provided with various inner diameter according to requirement of cable size.
Complete dust & vermin proof confirming to IP55 with locking and sealing arrangement..
No secondary circuit wires are accessible outside which avoids chances of energy theft.
Stable accuracy over life time.
Provision of installing modem inside the cubicle provided
Non hygroscopic CT's.
Application:- Precision check metering, control indication...
Largely used for Metering of LT consumers .

Specification
SL.Particulars Unit Description
1 Type of Box Sheet Metal or SMC
2 Type of CT Epoxy Resin Cast Bar Primary L.T.C.T
3 Operating System Voltage V 230 , 440
4 Power Frequency Dry KVp(rms)
3 to 6
withstand Voltage
5 Transformation ratio Amp 50 to 1200 or as per requirement
6 Rated Secondary Current Amp 5.0
7 Fault Level of CT KA upto 6 KA for 1 or 3 sec
8 no 4 Nos for 3Phase 4W ire System
No of CT
3 Nos for 3Phase 3W ire System
9 Output Burden VA Upto 30 at 0.8 pF lag.
10 Accuracy class -
EPOXY RESIN CAST PILFER RESISTANT METERING CUBICLE/PANEL

Types:- 11KV to 33KV Voltage Class


3 no C.T's & 3 No Single Phase VT'S
3 no C.T's & 1 No Three Phase VT'S
Features:- Compact in design, Low cost and maintenance free.
Separate Meter compartment and CT-PT compartment.
Available in 3Phase 3W ire and 3Phase 4W ire systems.
CT's & PT's are epoxy molded to avoid any pilferage.
Complete dust & vermin proof confirming to IP55 with locking and sealing
arrangement.
No secondary circuit wires are accessible outside which avoids chances of energy
theft.
Stable accuracy over life time.
Designed mainly for Indoor applications
Non hygroscopic CT's & PT's.

Application:- Precision Revenue metering, control indication.


Used for Double Metering of Transformers.
Used on Feeder Metering for energy accounting.

Specification
SL. Particulars 11 KV 15 KV 22 KV 33 KV
1 Highest System Voltage kV 12 17 24 36
2 Power Freq dry/wet withstand voltage KVp rms 28 36 50 70
3 Lightning Impulse Voltage 1.2/50 s KVp 75 110 125 170
4 Partial Discharge Measuring Voltage/ Limit. KV/pC 7.6KV/50pC 10.8KV/50pC 15.2KV / 50pC 23KV / 50pC
5 Transformation ratio Amp As per customer requirement.
6 Rated Primary Current Amp Upto 1000 Amp
7 Rated Secondary Current Amp 1.0, 5.0
8 Rated Secondary Voltage Volts 110/3 for Ph-Neutral, 110 for Ph-Ph
9 Rated Secondary Current Amp 1.0, 5.0
10 Short Time Current Rating KA(rms) Upto 25KA for 1 or 3 sec
11 VA Upto 30 at 0.8 pf lag for CT
Out put Burden
Upto 100 at 0.8 pf lag for PT
12 Accuracy class -
For CT - 0.2, 0.2s, 0.5, 0.5s, 1.0, 3.0 & 5.0
For VT - 0.2, 0.5, 1.0
Office address :

F-285, UPSIDC, Khichra Industrial Area, Meerut-


Guwahati Road,
Ghaziabad 201001, UP, India

Phone No. : +91-9210927863 / +91-9313115696/ +91-9868667484


E-mail ID : mew.ctpt@gmail.com /
luckyindiapowersolutions@gmail.com / info@luckyindiapowersolution.com

Contact Details :

Mr. Shokaut Ali / Mr. Sharafat Ali

Phone No. : +91-9313115696 / + 91-9868667484


E-mail ID : mews.ctpt@gmail.com / luckyindiapowersolutions@gmail.com /
anjni10@rediffmail.com

Mr. DINESH GOEL

Phone No. : +91-9818884692 / +91-9012184692


E-mail ID : dgoel90@gmail.com / anjni10@rediffmail.com

http://www.indiamart.com/jayaelectricals

You might also like