You are on page 1of 6

For T-1202

Stream 10

Stream 8
T-1202
Stream 11

Stream 8

kg kg
Mass of stream: 5640 x 1.25 = 7050
hr hr

kmol kmol
Mole flowrate of propane : 0.00 x 1.25 = 0.00
hr hr

kmol kmol
Mole flowrate of propylene: 0.00 x 1.25 = 0.00
hr hr

kmol kmol
Mole flowrate of i-butane: 0.16 x 1.25 = 0.20
hr hr

kmol kmol
Mole flowrate of n-butane: 0.69 x 1.25 = 0.8625
hr hr

kmol kmol
Mole flowrate of i-butene: 0.08 x 1.25 = 0.10
hr hr

kmol kmol
Mole flowrate of 1-butene: 0.45 x 1.25 = 0.5625
hr hr

kmol kmol
Mole flowrate of 1-Hexene: 21.00 x 1.25 = 26.25
hr hr

kmol kmol
Mole flowrate of 1-Heptene: 26.52 x 1.25 = 33.15
hr hr

kmol kmol
Mole flowrate of 1-Octene: 7.41 x 1.25 = 9.2625
hr hr

kmol kmol
Mole flowrate of 1-Undecene: 2.34 x 1.25 = 2.925
hr hr
Total mole flowrate: 0.00 + 0.00 + 0.20 + 0.8625 + 0.10 + 0.5625 + 26.25

kmol
+33.15+9.2625+2.925 = 78.3125
hr

Stream 10

kg kg
Mass of stream: 1860 x 1.25 = 2325
hr hr

kmol kmol
Mole flowrate of propane : 0.00 x 1.25 = 0.00
hr hr

kmol kmol
Mole flowrate of propylene: 0.00 x 1.25 = 0.00
hr hr

kmol kmol
Mole flowrate of i-butane: 0.16 x 1.25 = 0.20
hr hr

kmol kmol
Mole flowrate of n-butane: 0.69 x 1.25 = 0.8625
hr hr

kmol kmol
Mole flowrate of i-butene: 0.08 x 1.25 = 0.10
hr hr

kmol kmol
Mole flowrate of 1-butene: 0.45 x 1.25 = 0.5625
hr hr

kmol kmol
Mole flowrate of 1-Hexene: 20.79 x 1.25 = 25.9875
hr hr

kmol kmol
Mole flowrate of 1-Heptene: 0.27 x 1.25 = 0.3375
hr hr

kmol kmol
Mole flowrate of 1-Octene: 0 x 1.25 = 0
hr hr

kmol kmol
Mole flowrate of 1-Undecene: 0 x 1.25 = 0
hr hr
Total mole flowrate: 0.00 + 0.00 + 0.20 + 0.8625 + 0.10 + 0.5625 + 25.9875 +0.3375

kmol
= 28.05
hr

Stream 11

kg kg
Mass of stream: 3790 x 1.25 = 4737.5
hr hr

kmol kmol
Mole flowrate of propane : 0.00 x 1.25 = 0.00
hr hr

kmol kmol
Mole flowrate of propylene: 0.00 x 1.25 = 0.00
hr hr

kmol kmol
Mole flowrate of i-butane: 0.00 x 1.25 = 0.00
hr hr

kmol kmol
Mole flowrate of n-butane: 0.00 x 1.25 = 0.00
hr hr

kmol kmol
Mole flowrate of i-butene: 0.00 x 1.25 = 0.00
hr hr

kmol kmol
Mole flowrate of 1-butene: 0.00 x 1.25 = 0.00
hr hr

kmol kmol
Mole flowrate of 1-Hexene: 0.21 x 1.25 = 0.2625
hr hr

kmol kmol
Mole flowrate of 1-Heptene: 26.26 x 1.25 = 32.825
hr hr

kmol kmol
Mole flowrate of 1-Octene: 7.41 x 1.25 = 9.2625
hr hr

kmol kmol
Mole flowrate of 1-Undecene: 2.34 x 1.25 = 2.925
hr hr

Total mole flowrate: 0.00 + 0.00 + 0.00 + 0.00 + 0.00 + 0.00 + 0.2625 +32.825

kmol
+9.2625 +2.925 = 45.275
hr
TOWER T-1202

Stream 10

Stream 8
T-1202
Stream 11

[ ]
x
( )
1x overhead
Rule 7 : x
( )
1x bottom
Nmin=ln
ln avg

Rule 5: Opt reflux ratio (1.2-1.5 Rmin)

F
Rule 8 :
Rmin=
( D) , avg=( overhead X bottom)
1
2

avg 1

Rule 6 : theoretical trays, 2 N min


N theoretical
N actual = (1.1)
tray

Rule 9 : Safety factor , 10% on no. of trays.

mL
Rule 14 : Lmax =53 <30
D

Rule 3 : Ptray =0.007

Rule 4 : trays 6090 , tray spacing(0.50.6)

25.98775
x overhead =
28.05

0.9 3

x 0.93
= =13.29
1x 10.93

0.2625
x bottom =
45.275

0.00 58

x 0.0058
= =0.00 58
1x 10.0058

P sat
1 1179
overhead = sat
= =2.5 3
P2 466.84

sat
P1 4960.58
bottom = sat
= =2.85
P2 1740.55

avg=( overhead x bottom )0.5=( 2.53 x 2.85)0.5=2.3 2

[ ]
x
( )
1x overhead
x
( )
1x bottom
Nmin=ln
ln avg

Nmin=ln
13.29
0.00 58[=9.19
]
ln 2.32

N theoret ical =2 N min =2 ( 9.19 )=18.39


N theoretical 18.39
N actual = ( 1.1 )= ( 1.1 )=33.71 number of tray s
tray 0.6

F 78.3125
Rmin =
( D ) =
( 28.05 )
=2.12
avg 1 2.321

R=1.2 Rmin =1.2 ( 2.12 )=2. 54

R=1.5 Rmin =1.5 ( 2.12 )=3.18

Height of tower= ( spacing ) ( N actual ) ( 3 m )=( 0.6 )( 33.71 ) ( 3 )=60.68 m

PTower =( N actual ) ( P Power )=33.71 ( 0.007 )=0.23597 ba r