Professional Documents
Culture Documents
Pno = 197,994 kN
C3 = 0.8578
EIeff = 21,150,219 kNm
Pe = Pe = 8,217,762 kN
Pn0 / Pe = 0.024
Pn = 196,007 kN
cPn = 147,005 kN
PAGE: 2/ 2
III. Flexural Strength (conservatively based on pipe and concrete only) RATIO: 0.07
For compact section: AISC
Mnx = Fy ZsB + 0.95 f'c ZcB/2 Mnx = 44,180 kNm Design
Mcx = bMnx = 39,762 kNm Example
Mny = Mnx V14.1
Mny = 44,180 kNm
d=D= 1500 mm Mcy = bMny = 39,762 kNm
h= 1400 mm
ZsB = 95,279,595 mm
ZcB = 340,093,429 mm
= 2.267 rad
Kc = 137,200,000 N
Ks = 12,506,250 N
H1-1a
Pr/Pc = 0.861
H1-1b
ratio = 0.952
Vn = 21,216 kN
Pn = 107,435 kN I2-8
Pn = 96,692 kN
VII. Flexural and Axial Tension RATIO: 0.10
H1-1a
Pr/Pc = -
H1-1b
ratio = 0.103