Benchtop Digital Thermometer

Single- and Ten-Channel Models


Shown smaller
than actual size.

MDSS41-TC-GN, shown with TTSS-18U-6 transition


junction and quick-disconnect thermocouples, sold MDS41-TC, shown with GKMQSS-125U-6
separately. Visit omega.com/ktss_jtss_chb miniature quick-disconnect probes, sold
separately. Visit omega.com/gjmqss

MDS41 Series
With compliments
Helmut Singer Elektronik
www.helmut-singer.de info@helmut-singer.de
fon +49 241 155 315 fax +49 241 152 066
Feldchen 16-24 D-52070 Aachen Germany

Front Panel Programmable for


9 Thermocouple Calibrations
0.2 Accuracy for Temperature
0.01 Resolution
Min/Max Storage
Optional Analog Output
Optional RS232 Communications Rear panel showing sub-D connector
115 Vac Power for optional RS232 output.

The MDS41 is a high-precision digital benchtop meter,


with 2 models that accept either thermocouple or
RTD inputs. The large, easy-to-read 13 mm (0.5") To Order Visit omega.com/mds_mdss for Pricing and Details
display features 6 digits with 0.01 resolution. The Input No. of
thermocouple input model has 9 thermocouple Model No. Type Channels
types in memory, any one of which can be selected
through the front panel. The RTD input model can be MDS41-TC Thermocouple 1
programmed for a linear resistance or one of two MDSS41-TC Thermocouple 10
100 1 platinum curves, 0.00385 or 0.00392 (2- or MDS41-RTD RTD 1
3- wire RTD). The unit is switchable to C/F/K.
MDSS41-RTD RTD 10
The single-channel unit includes a universal rear
connector which accepts either the miniature or Red LED display and 115 Vac power are standard.
For green LED display, add suffix -GN to model number,
standard quick disconnect connector. The 10-channel no additional cost. For analog output, add suffix -A to model number,
MDSS uses screw terminals for temperature input. no additional cost.
Optional scalable analog output is available and can Note: The analog output for the MDSS models is for the displayed
be ordered as a 0 to 10 Vdc or 4 to 20 mA. The analog channel only. To order units with optional RS232 communications,
add suffix -S2 to model number, no additional cost.
output provides a retransmission of the measured Ordering Examples: MDS41-TC, single-channel benchtop indicator,
temperature for recorders or dataloggers. thermocouple input.
Visit omega.com/dp41 for more information on the MDS41-RTD-A, single-channel benchtop indicator, RTD input and
DP41 series. analog output.

M-105
MDS41-TC high-accuracy benchtop
thermometer shown smaller than
actual size, with KMTXL-125U-6 Type K
molded transition joint thermocouple.
Visit omega.com/kmtxl_nmtxl

Shown smaller
than actual size.

Economical Series Benchtop


The DS (single-input) and the DSS Monogram Series Description
(10-input) benchtop cases are
OMEGAs more economical cases. MDS (*) Single-input benchtop meter
The DS and DSS cases maintain MDS-02 (*) Single-input with rechargeable battery option
the versatility of panel meters and
the portability of a benchtop. The MDSS (*) 10-input benchtop meter
DS and DSS are a beige color. MDSS-02 (*) 10-input with rechargeable battery option
Economical Series Description M
OMEGACARESM extended
SM warranty program is available
DS (*) Single-input benchtop meter
for models shown on this page.DSS (*) 10-input benchtop meter
Ask your sales representative
for full details when placing * Insert model number of meter and thermocouple type.
Extended Warranty an order. OMEGACARESM
Program covers parts, labor and Refer to omega.com/sel_guide_meter for the digital Panel Meter Selection Guide
equivalent loaners. for Additional Meters and Specifications.

Benchtop Model No.


Battery Serial Analog
Single-Channel 10-Channel Base Meter Specs Option Comm. Output
MDS41-TC MDSS41-TC DP41-TC M-27 MDS-02 Opt Opt
MDS41-RTD MDSS41-RTD DP41-RTD M-27 MDS-02 Opt Opt
MDS116-(*) MDSS116-(**) DP116-(**) M-13 MDS-02 Std
MDS25B-(*) MDSS25B-(**) DP25B M-17 MDS-02 Opt
Comes complete with operators manual.
** Insert thermocouple type or the meters specific range code.
For 10-channel models, communication port can only access input currently selected by 10-point selector switch on front of unit.
Note: The benchtop models using the DP41-TC is programmable for any thermocouple type listed on the meters specification sheet.
To order the DS version one channel replace the MDS in the model number with DS, and subtract cost from the MDS price.
To order the DSS ten channel version replace the MDSS in the model number with DSS, and subtract cost from the MDSS price.
Ordering Examples: MDS116-JF, single-channel benchtop indicator, Type J thermocouple input, F.
OCW-2, OMEGACARESM extends standard 3-year warranty to a total of 5 years.

M-106
8 DIN HIGH-PERFORMANCE METERS
1
ALARM/CONTROL CAPABILITIES
STRAIN GAGE, PROCESS VOLTAGE AND CURRENT, TEMPERATURE

DP41 Series

DP41-S strain
meter shown
actual size.

All Units Feature:


Voltage/Current Inputs: Standard features include 6-digit
5-Year Warranty display; 5 front-panel pushbutton
0.005% Rdg Accuracy
6-Digit Display keys; 4 open-collector outputs; and
10 User-Selectable alarm/control, BCD, and analog
Min/Max Storage Voltage or 4 to 20/ outputs. Configurable analog output
4 Isolated Open-Collector 0 to 20 mA Input Ranges ranges are 0 to 20 mA, 4 to 20 mA,
Outputs Fully Scalable Display Up 0 to 5 Vdc, and 0 to 10 Vdc.
NEMA 4 (IP65) Front Panel to 500,000 Counts On-board excitation allows these
12 Readings per Second 1.5 to 11 Vdc or 24 Vdc
meters to power virtually any sensor
or transmitter, and 4 setpoints give
Alarm/Control Capabilities Sensor Excitation the user numerous control/alarm
Smart Filtering Detects Adjustable Decimal Point possibilities. Setpoint configurations
the Difference Between a include active above or below;
Spike or Process Change The OMEGA DP41 Series of digital latching or non-latching; and high
(Patent Applied for) panel meter/controllers has set the deviation, low deviation, or band
world standard for accuracy and deviation.
Peak and Valley Detection
quality in industrial instrumentation. With the RS232/485 serial
Digital Tare These meters can measure a broad communications option, the user
Easy Front-Panel spectrum of DC voltage and current can set the display parameters
Programming ranges as well as inputs from and read the current, max, and
9 thermocouple types and from min values remotely. The DP40-R
Optional BCD Output most RTDs, pressure transducers, board option provides dual 7 A
Optional Analog Output load cells, strain gages, and mechanical relays, activated by the
Optional RS232/RS485 potentiometers. Models include the selected setpoint.
Communications DP41-W, a legal-for-trade, NTEP-
certified strain meter with enhanced
Optional Mechanical Relays features, and the DP41-U, which
Thermocouple Input: covers all the input types.
0.01 Resolution
0.2C Accuracy The DP41 displays feature 14-segment LED characters, which greatly improves
alphanumeric representations. The 7-segment LED characters found on most
9 Thermocouple Types instruments are adequate for presenting
C/F/K Units numbers, but not
Uses Complete NIST letters. Words are
Calibration Tables easier to read with
the 14-segment 14-segment display
RTD Input: LED characters on 14-segment LED
0.01 Resolution the DP41, which,
in turn, simplifies
0.2C Accuracy operating and
2-, 3-, or 4-Wire programming. 7-segment display
7-segment LED
Red LED display standard. Also
available with green LED at no charge.
385 and 392 Pt Curves
D-29
HIGH-PERFORMANCE METERS

SPECIFICATIONS Offset Adjustment: 0 to 999,999 or Sensor Break Protection: Up-scale or


Accuracy: 0.005% rdg 0 to -99,999, programmable down-scale, programmable
Span Temperature Coefficient: 20 ppm Thermocouple Input Types: Sensor Excitation: 10 V at 30 mA;
Step Response: 1 s to 99.9% J, K, T, E, R, S, B, N, J DIN 24V at 25 mA
Warm-Up to Rated Accuracy: 50 minutes RTD Input: Any 6 1 to 6 k1 NIST or
DIN platinum and any linear RTD
Operating Environment: 0 to 50C
(32 to 122F); 95% RH, non-condensing RTD Connection: 2-, 3- or 4-wire
Storage Temperature:
-40 to 85C (-40 to 185F)
Power: 115 or 230 Vac, 49 to 400 Hz;
10 to 32 Vdc
Power Consumption: 6 W nom., 10 W max
Normal-Mode Rejection: 60 dB The DP41 thermocouple meter offers very high accuracy ensured by an
Common-Mode Rejection: 120 dB advanced (patent applied for) thermocouple linearizing system. Accuracy
for most thermocouple types is 0.2C (3.6F). The meter is front-panel
Common-Mode Voltage: programmable for any of 9 thermocouple types. The DP41 RTD input meter
1500 Vp per HV test
is programmable for any 6 to 6000 1 DIN or NIST platinum RTD. It provides
Resolution: 15-bit a precision ultra-low constant current excitation to minimize self-heating
Conversion: Dual-slope technique errors and maximize stability.
Reading Rate: 3/s or 13/s, 60 Hz;
3/s or 12/s, 50 Hz INPUT TYPE RANGE, C RANGE, F ACCURACY
Display: Red or green 6-digit, 14-segment,
13.7 mm (0.54") high; 4 alarm indicators Iron-constantan -210 to 760 -346 to 1400 0.2C/0.3F
Dimensions: 48 H x 96 W x 165 mm D CHROMEGA-ALOMEGA -270 to 1372 -454 to 2500 0.2C/0.3F
(1.89 x 3.78 x 6.5")

INSTRUMENTATION
Copper-constantan -270 to 400 -454 to 752 0.2C/0.3F
Panel Cutout: 45 H x 92 mm W
(1.772 x 3.622"); 18 DIN CHROMEGA -constantan

-270 to 1000 -454 to 1832 0.2C/0.3F
Weight: 574 g (1.27 lb) / Pt/Rh -50 to 1768 -58 to 3214 0.2C/0.3F
Setpoint Outputs: 4 isolated open Pt/30% Rh-Pt/6 Rh 100 to 1820 212 to 3300 0.3C/0.5F
collector; rated 150 mA at 1V sink,
30V open OMEGALLOY -270 to 1300 -454 to 2372 0.2C/0.3F
BCD Output: Isolated, tri-state, Iron-constantan -200 to 900 -328 to 1652 0.6C/1.0F
TTL/CMOS compatible; external
5V supply required for isolated; All curves -200 to 850 -328 to 1562 0.2C/0.3F
internal 5V supply for non-isolated
Dual Relays: Form C, 7 A @ 30 Vdc
or 230 Vac INPUT TYPE RANGE, C RANGE, F RANGE, K ACCURACY D
4-Relay Option: Dual 7 A relays RTD 1 10 1 copper -200 to 200 -328 to 392 73.2 to 473.2 1.0C/2.0F/1.0 K
and dual 1 A relays
Analog Output: 0 to 5V/1 to 5V/ RTD 2 100 1 Pt 0.00385 200 to 900 -328 to 1652 73.2 to 1173.2 0.2C/0.3F/0.2 K
0 to 10V/0 to 20 mA/4 to 20 mA, user RTD 3 100 1 Pt 0.00392 -200 to 850 -328 to 1562 73.2 to 1123.2 0.2C/0.3F/0.2 K
selectable; 354 Vp isolation; 15-bit
resolution; 0.1% accuracy; 50 ms
step response
RS232 Communications: Thermocouple and RTD
300/600/1200/2400/4800/9600/ probes sold separately. Visit
omega.com/temperature,
19.2K baud; RJ11 4-wire connection; for the complete selection
programmable to transmit current of temperature products
display, alarm status, min/max, actual available from OMEGA
measured input value and status
RS485 Communications:
300/600/1200/2400/4800/9600/
19.2K baud; RJ12 6-wire connection;
addressable from 0 to 199
Voltage Input Ranges: 0 to 100 mV,
0 to 1V, 0 to 5V, 1 to 5V, 0 to 10V,
0 to 100V, 50 mV, 500 mV, 5V, 50V
Current Input Ranges: 0 to 20 mA,
4 to 20 mA
Input Configuration: Single-ended
Polarity: Unipolar/bipolar, programmable
Span Adjustment: 0.00001 to 500,000, DP41-T and DP41-RTD shown
programmable smaller than actual size.

D-30
HIGH-PERFORMANCE
METERS

DP41Z-E split meter with


remote display, panel mount or
surface mount with bracket shown
smaller than actual size.

To Order Visit omega.com/dp41 for Pricing and Details


MODEL NO. DESCRIPTION
DP41-E Process voltage/current indicator
DP41-S Strain gage indicator
DP41-W Weight NTEP strain indicator
DP41-TC Thermocouple indicator
DP41-RTD RTD indicator
DP41-U Universal input indicator
DP41Z-E Split-display voltage/current indicator
DP41-TBS bench stand,
sold separately. DP41Z-S Split-display strain gage indicator
DP41Z-W Split-display weight NTEP strain indicator
DP41Z-TC Split-display thermocouple indicator
DP41Z-RTD Split-display RTD indicator
DP41-TC with thermocouple probe, sold DP41Z-U Split-display universal input indicator
separately, shown smaller than actual size.
POWER AND DISPLAY OPTIONS
SUFFIX DESCRIPTION
-230 230 Vac power
ANALOG OUTPUT/COMPUTER COMMUNICATIONS -DC 10 to 32 Vdc isolated power
MODEL NO. DESCRIPTION -GN Green LED display
DP40-A3 Analog output
ACCESSORIES FOR COMPUTER COMMUNICATIONS
DP40-S24 Isolated RS232/485 communications
MODEL NO. DESCRIPTION
DP40-S24 option comes with communications cable with phone plug
termination. For proper termination to a computer, 9-pin and 25-pin DP40-9SC2 9-pin serial connector for RS232
connectors are offered below.
DP40-9SC4 9-pin serial connector for RS485
CONTROL/BCD OUTPUTS DP40-25SC2 25-pin serial connector for RS232
MODEL NO. DESCRIPTION DP40-25SC4 25-pin serial connector for RS485
DP40-B Isolated BCD output board* ACCESSORIES FOR DP41 METERS
DP40-R Dual 7 A mechanical relays* MODEL NO. DESCRIPTION
DP40-R4 Dual 7 A and Dual 1 A relays* SPC4 NEMA 4 (IP65) heavy-duty
*Note: Order DP40-B, DP40-R or DP40-R4; only 1 option can be splashproof lens, screw clamp
used per unit. DC power option not available on models with
With
DP40-Rcompliments
or DP40-R4.
SPC18 NEMA 4 (IP65) splashproof lens,
spring clip
Helmut Singer
DP41 unit for thermocouple Elektronik
Ordering Example: DP41-TC-DC-S2A and DP40-9SC2,
inputs, with 10 to 32 Vdc power, DP41-TBS Economical bench stand
RS232 communications, analog output and 9-pin serial connector.
www.helmut-singer.de info@helmut-singer.de DPP-5 8 DIN panel punch
1

fon +49 241 155 315 fax +49 241 152 066
Feldchen 16-24 D-52070 Aachen Germany D-31
8 DIN HIGH-PERFORMANCE
1

PROCESS INDICATORS
DP41 SERIES
DP41-S
shown smaller
than actual size.

96.0 (3.78) Visit omega.com/panelpunches


for 18 DIN panel punches.

48.0 (1.89) 48.00 (1.890) 96.00 (3.78)

SETPTS MAX MIN MENU RESET CASE


20.3 (0.80)
1/8 DIN
FRONT VIEW
TYP
SLEEVE

INSTRUMENTATION
92.00 +0.81/-0.00 PANEL THICKNESS
92.0 (3.62) (3.622 +.032/-.000)
6.4 (0.25) MAX
0.8 (0.03) MIN
P18 P9 155.8 (6.13) MAX
R 0.06 (1.6)
P6 P7
J4 P5 45.0 (1.77) 4 PLCS
P1
P3
P2

45.00 +0.61/-0.00
REAR VIEW (1.772 +.024/-.000)
TYP PANEL CUTOUT
Dimensions:
mm (in)
SIDE VIEW
WITH T/C COVER
TOP VIEW
WITH T/C COVER D
20.3 (0.80) 15.9 (0.63)

SIDE VIEW
THROUGH PANEL MOUNT

61.0 (2.40)

SIDE VIEW OF
SURFACE MOUNT
DP41Z-E shown