CICLO: VII
HUACHO - PERU
INTRODUCCION
lll RESULTADOS:
Parmetros Terico Simulado Implementado
V BB 3.6 V 3.57 V 3.7 V
VE 2.9 V 2.91V 3V
IE 0.9 MA 0.88 MA 1 MA
IC 0.9 MA 0.87 MA 1 MA
VC 8.02V 8. 57V 8.1 V
V CE 5.12V 5.17 V 5.2V
I C (sat) 1.82 MA 1.82 MA 2 MA
V CE(corte) 1 0V 10 V 10 V
GRAFICA:
la reta de la carga y el punto de operacin (valor terico)
lV ANALISIS:
( R 2+R 2R 1 )V =( 10+5.6
V BB = CC
5.6
)10 V =3.6 V
E=V BBV BE=3.6 V 0.7 V =2.9 V
V
V E 2.9 V
I E= = =0.9 MA
R E 3.3 K
I C I E=0.9 MA
V CE =V C V E=0.822.9 V =5.12 V
V CC 10 V
I C ( sat )= = =1.82 MA
RC + R E 2.2 K +3.3 K
V CE ( corte)=V CC=10 v
Hallar C1 =?
1 1
XC= C 1=
2 f C1 2 f Xc
(10 K5.6 K ) 56 K
R=R 1/ R 2= = =3.6 K 3600
10 K +5.6 K 15.6 K
X C =36000.1=360
1
C1 = =4.42uf
2 (100 Hz)( 360 )
Hallar C2 =?
1 1
XC= C 2=
2 f C2 2 f Xc
1
C2 = =1.06 uf
2 (100 Hz)(1500 )
25 mv 25 mv
re= = =27.8
IE 0.9 mA
3627.8 3300
RT =R 5/ = =1728.072
3627.8 +3300
1
C 3= =9.214 uf
2 (100 Hz)(172.81 )
C2 1.06 uf 1uf
C3 9.214 uf 10 uf
AMPLIFICADOR
SIMULACIN DE LOS
-El haber analizado de tres maneras diferentes el circuito, nos tom diferentes
medidas, la cual nos ofrece aproximaciones distintas para el diseo.
Cuando se realiz el clculo de manera terica, en el caso de los dos
condensadores, la de acoplo y desacoplo, estas tomaron valores decimales y
para la simulacin debimos elegir los componentes un poco ms exactos.
En cambio, cuando ya nos toc realizar la implementacin fsica, ya tenamos
que estimar los valores ms prximos a los componentes que se venden el
mercado.
Esto nos demuestra que hay muchas formas de aproximar nuestros valores,
incluso una solucin a esto sera ya sea sumando componentes en serie o
paralelo para acercarnos ms a nuestro valor deseado, pues mientras ms
prxima, mejor se adaptara a lo que queramos.
.
Vl ANEXOS:
procediendo a colocar los materiales en el protoboard