Main features
Non-eiectric requirements.
OPTIONS: Stainless steel construction.
Stainless steel check valves.
Level gauge.
Stroke counter.
To Iift condensate or hot and
USE: cold liquids.
AVAl LABLE
MODELS: TW 33 - Carbon
Steel body.
TW 33 - Stainless
Steel body.
APPLICATION LIMITS
Minimum density:..........................0.80 kg/dm3
Maximum viscosity:...........................5o Engier
Supply operating pressure: trom.....0.5 to 8.6 bar FLOW RATE CAPACITY IN Kg/h
PMA:Max.allowable pressure..............25 bar Installed with recommended filling head above cover of pump ol 0.3 m
TMA:Max.allowable temperature..........250 oC (Liquid specific gravity 9 - 1.0)
PMO:Max.operating pressure..............8.6 bar Operating inlet Total lift back Capacity kg/h pump size DN
TMO:Max.operating temperature...........200 oC pressure pressure
A receiver is recommended to temporarily Pump size 1" 11/2" 2" 3" x 2"
hold.the liquid and prevent any flooding of Pipe size with 1 m length 6" 8" 10" 12"
the equipment, while the pump is in the
pumping cycle. A Iength of pipe of large
diameter or a tank can also be used.
Example
Conditions: Stroke counter
Condensate Ioad..........................1900 Kg/h Available on request ,it can be
Filling head.........................................0.15 m screwed directly into the top cover
Motive gas...............................................Air of the pump or above the pump
Pressure available............................6.9 bar through a 1/2" size pipe for easier
Vertical Iift after pump..............................6m reading (max. 1 m).
Return piping pressure....................1.5 bar
Piping friction pressure drop.........negligible Each stroke 25 liters of Iiquid are
pumped. The counter has 7digits.
Calculations
Total back pressure:
1.5 bar + (6m x 0.0981) = 2.09 bar
Pump choice, assuming steam for motive
pressure of 6.9 bar and a back pressure of PACKAGED AUTOMATIC PUMP UNIT
2.8 bar, the 2" pump has a capacity from (SUITABLE FOR STEAM SUPPLY)
flow rate capacity chart 1, of 2765 Kg/h.