Problem 3.1 A space is at a temperature of 75 F (24 C), and the relative humidity is 45 percent. Find: (a) the partial pressures of the air and water vapor, (b) the vapor density, and (©) the humidity ratio of the mixture, Assume standard sea-level pressure Problem 3.2 Determine the humidity ratio, enthalpy, and specific volume for saturated ait at one standard atmosphere using perfect gas relations for temperatures of: (a) 80 F 27 C) and (b) 32 F(0O). Problem 3.23 Air at 38 C db and 20 C wh is humidified adiabatically with liquid water supplied at 60 C in stich proportions that a relative humidity of 80 percent results. Find the final dry bulb temperature, Problem 3.25 Air at 40 F (5 C) db and 35 F (2 C) w bis mixed with warm air at 100 F (38 C) db and 77 F (25 C) wb in the ratio of 2000 cfin cool air to 1000 cfm warm air. Find the resulting humidity ratio and enthalpy using psychrometrie Chart 1a on the basis of volume flow rates. Problem 3.27 The design cooling load for a zone in a building is 250 000 Btwhr (73 kW), of which 200 000 Brwhr (59 kW) is sensible cooling load. The space is to be maintained at 75 F (24 C) dry bulb temperature and 50 percent relative humidity. Locate the space condition line on Charts 1a and 1b and draw the condition line. Problem 3.28 Assume that the air in Problem 3-27 is supplied to the space at 53 F (12 C). Compute the volume flow rate of the air required in: (a) English units and (b) ST units. Problem 3.48 Conditions in one zone of a dual-duct conditioning system are to be maintained at 75 F (24. ©) and 50 percent relative humidity (RH). The cold deck air is at 52 F (11 C) and 90 percent RH. while the hot deck air is outdoor air at 90 F (32 C) and 20 percent RH. The sensible heat factor for the zone is 0.65. Assume sea-level pressure. In what proportion must the warm and cold air be mixed to satisfy the space condition? If the total zone load is 50 tons (176 kW), what is the total volume flow rate of air supplied to the zone? Sketch the states and processes ona psyehrometric chart, Use (a) English units and (b) ST units Problem 3.52 Under normal operating conditions a zone has a total cooling load of 120 000 Bru/hr (35 KW) with a SHF of 0.8, The space is to be maintained at 74 F (23 C) db and 50 ®% relative humidity (RH). However, there are periods when the latent load is high and the SHF is estimated to be as low as 0.6. Assume that ait enters the cooling coil at 85 F (29 C) db and 71 F (22 C) wb and the coil apparatus dew point is 48 F (9 C) (a) Devise a system and the associated psyehromettic processes to cover the necessary range of operation. (b) Define the various air states and show the processes on Chart 1a. (©) Compute air-flow rate, coil load, minimum zone load, and any reheat that may be required, Assume constant air flow and standard sea-level pressure

You might also like