iT600 Wiring Centre KL10RF 004_Layout 1 05/06/2014 15:24 Page 1

KL10RF
Installation and wiring guide

OPTIONAL BATTERY POWERED MAINS POWERED BATTERY POWERED MAINS POWERED BATTERY POWERED MAINS POWERED BATTERY POWERED OPTIONAL
HOT WATER TIMER PROGRAMMABLE PROGRAMMABLE PROGRAMMABLE PROGRAMMABLE PROGRAMMABLE PROGRAMMABLE PROGRAMMABLE PROGRAMMABLE
(MODEL VS10WRF
or VS20WRF)
ROOM THERMOSTAT
VS20WRF)
(MODEL VS20WRF
ROOM THERMOSTAT
(MODEL VS10WRF)
ROOM THERMOSTAT ROOM THERMOSTAT ROOM THERMOSTAT ROOM THERMOSTAT ROOM THERMOSTAT ROOM THERMOSTAT
RADIATOR ZONE
2

2 1 L N 2 1 L N 2 1 L N 2 1 L N 2 1 L N

1.5MM 2 3 CORE 1.5MM 2 3 CORE

1.5MM 2 CABLE
(INSTALLER SUPPLIED) 7
230V 8 FACTORY
FITTED
LINK
FACTORY
FITTED
LINK
FACTORY
FITTED
LINK
3
4
1.5MM 2 CABLE
(INSTALLER SUPPLIED)
COLOURS ARE INDICATIVE ONLY.
OUT

EXTRA CONNECTIONS MAY BE REQUIRED


IN

IN OUT BR EA N OR GR IN OUT L N E IN OUT BR EA N OR GR

6
AS PER MANUFACTURERS INSTRUCTIONS HW CYLINDER
FUSE
HW MOTORISED VALVE OVERHEAT STAT UFH PUMP BOILER ENABLE UFH MOTORISED VALVE
THERMOSTAT

FUSE
OUT
IN

5
- - - - - - - - - + + + + + + + + +
THERMOSTAT NEUTRAL CONNECTIONS THERMOSTAT LIVE CONNECTIONS
L N L N L N L N L N L N L N L N L N L N L N L N L N L N L N L N

9
ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8
OPTIONAL
CYLINDER STAT Meets the following EC Directives
Electro-Magntic Compatibility directive 2004 / 108 / EC
Low voltage Directive 2006/95/EC

1.5MM 2 CABLE (INSTALLER SUPPLIED)

1.5MM 2 CABLE These instructions are applicable to the SALUS model


(INSTALLER SUPPLIED)
stated above.
SUPPLIED CABLES

Warning
This product must be fitted by a competent person, and
installation must comply with the guidance, standards and
regulations applicable to the city, country or state where the
product is installed. Failure to comply with the requirements
of the relevant guidance, standards and regulations could lead
2 OPTIONAL UFH ZONE VALVE 13 AMP FUSED CONNECTION UNIT to injury, death or prosecution.
FOR RADIATORS GROUPS FUSED AT 3 AMPS

Optional wireless
Warning
receiver RX10RF UNDERFLOOR HEATING MANIFOLD Always isolate the AC Mains supply before installing or working
230V TO UFH PUMP on any components that require 230 VAC 50Hz supply.
1.5MM 2 CABLE (INSTALLER SUPPLIED)

For PDF Installation guide please go to www.salus-controls.com

www.salus-controls.com Technical Helpline 00000 000000


Maintaining a policy of continued product development SALUS Controls plc reserve the right to change
specification, design and materials of products listed on this installation guide without prior notice.
Issue Date: June 2014 Document Number 00106
iT600 Wiring Centre KL10RF 004_Layout 1 05/06/2014 15:24 Page 2

KL10RF
Installation and Wiring Guide
Hot Water Connections
1 5 Thermostat Connections 8 Motorised Valves, Pump, Boiler & Stat Connections
OPTONAL HOT OPTONAL UPH
WATER MOTORISED Optional Cylinder Thermostat: If connecting the cylinder thermostat
MOTORISED VALVE REMOVE
VALVE LINK IF USED
directly to the timer then a link needs to be fitted between IN and OUT.
Optional Hot Water Motorised Valve: Used if timed hot water is required.
Optional Overheat Thermostat: Used for connecting a pipe thermostat to
Option 1
prevent over temperature water damaging sensitive floors. Remove the link
Connect Cylinder
and connect the pipe thermostat so it is Normally Closed. The pipe stat will
Thermostat to
open if overheating occurs and
wiring centre
the UFH pump will stop running.
IN OUT
HW CYLINDER
BR EA N OR GR IN OUT L N E IN OUT BR EA N OR GR Optional Boiler Enable: This Volt Free connection must come from the boiler
HW MOTORISED VALVE OVERHEAT STAT UFH PUMP BOILER ENABLE UFH MOTORISED VALVE
THERMOSTAT
thermostat connection, when any zone calls for heat the Boiler enable will
230V AC
THERMOSTAT CONNECTIONS 230V AC
close causing the boiler to run. If work is being carried out on the boiler then
HW TIMER CONNECTION ZONE 1 ZONE 2 ZONE 3 ZONE 4 Thermostat connections are to power the thermostats only, there
SL N L SL N L SL N L SL N L SL N L
power to and from the switch will
is no switched live needed as this is done with a wireless signal.
cease. (Do not connect to the boiler IN terminal by linking a 230V
Power can therefore be supplied to the thermostat locally from
feed from the wiring centre)
any convenient power source if connecting to the wiring centre
OPTONAL HOT OPTONAL UPH Optional UFH Motorised Valve: If a UFH motorised valve is
WATER MOTORISED from the thermostat is difficult. Battery powered RF thermostats
MOTORISED VALVE REMOVE fitted then remove the link between OR and GR.
VALVE LINK IF USED
can also be used. These can be mixed with 230v RF thermostats or
Optional Heat/Cool Changeover: This connection allows heat/cool
as an alternative.
changeover of all thermostats using a single external switch (installer supplied).
Option 2 Switch: Open-Heating Closed-Cooling
Connect Cylinder
Thermostat to RF
Thermostat for wire
free connection. A
6 Fuses Coordinator Ribbon Connection
link will be needed IN OUT
HW CYLINDER
THERMOSTAT
BR EA N OR GR
HW MOTORISED VALVE
IN OUT
OVERHEAT STAT
L N
UFH PUMP
E IN OUT
BOILER ENABLE
BR EA N OR GR
UFH MOTORISED VALVE 7 Information Display 3 2 Dip Switch Set Up
between IN & OUT In order for the wiring centre to be
THERMOSTAT CONNECTIONS 230V AC
as shown by arrow. 230V AC
HW TIMER CONNECTION ZONE 1 ZONE 2 ZONE 3 ZONE 4
able to control UFH and Radiators,
SL N L SL N L SL N L SL N L SL N L
there is a need to turn off the UFH
Thermostat Zones

Sensor Terminals pump for a zone when that zone is


Can be used for external AIR, Floor sensor
when configured as thermostat. Can also to be used for radiators.
be used for cylinder thermostat when Eg. When fitting a zone for radiators
connected for HW. NETWORK
BUTTON or towel rail then the Dip Switch for
When using option 2 refer to device that zone should be switched to OFF.
parameters on page xx of the manual. Groups
1
The Dip Switches for this are located
2 under the front lid. When the zone
switch is in the ON position the UFH
pump will run when that zone is
calling for heat along with the boiler.
9 Actuator Connections When it is in the OFF position then
the UFH pump will not run but the
A Coordinator will be
needed with all RF boiler will fire.
products. There are three other function
switches as well.
Pump & Boiler delay: This gives a
three minute delay to allow
4 Aerial Connection actuators to open before the boiler
fires.
After setting up the coordinator Pump Only Delay: Delays only the
will assign the wiring centre UFH pump from firing for three
number. This is because more than This must be carefully removed minutes.
1 wiring centre may be used on a or replaced when removing or Actuator NC or NO: This refers to
Actuator connections corresponding to the thermostat connections. Up to 2 project. Pressing the network replacing the wiring centre Normally Open or Normally Closed.
cables can be used in each connection (4 Actuators per Zone) If more, that button will illuminate the relevant cover, being careful to ensure This should be set to NC for
number needs to be connected, then an external junction box will be needed. number. The example shown is for the correct orientation. products.
A maximum of xxx actuators can be connected to a zone in this manner. wiring centre 1, if 1 & 2 are lit it
would be wiring centre 2.

www.salus-controls.com Technical Helpline 00000 000000