You are on page 1of 1

COMPLETION SYSTEM

Completion Configurations
Electric Submersible Completion Tubing Conveyed Perforating Completion

Tubing-conveyed
perforating guns can be
One schematic shows an run as tailpipe
electric submersible pump connected to the bottom
completion that allows of the packer
annulus gas below the or through the bore of a
packer to vent to the annulus set packer. This
above the packer. In an installation shows a
emergency Versa-Trieve packer
or when desired, hydraulic set on electric wireline.
control pressure is released The tubing-conveyed
from the control line guns are spaced out
allowing the gas vent sleeve below the seal
valve to close, sealing the assembly, and the
vent gas below the packer. A tubing is run in the hole.
common hydraulic control Before stabbing through
line can operate the tubing the packer, light fluids
retrievable safety valve and can be
annulus gas vent valve. circulated down the
The other schematic shows tubing to provide an
an electric submersible underbalanced
pump completion that allows situation. The tree is
flow control without installed and the
heavy kill fluids during guns are mechanically
remedial operations. A or hydraulically fired
downhole master valve is and released to open
run with a packer, on/off the tubing end.
tool, and wireline lock. The
valve holds pressure in
both directions. It closes
when the hydrostatic
pressureexceeds a preset
value and opens when
hydrostatic pressure is
reduced.

ESP Completion
TCP Completion