S/N Description of Activities Remarks
1 2 3
Check that SWL&ID marks are legible and corresponds with the
1
test certificate.
Check primary load bearing structure for corrosion, mechanical
2
damage and deformation.
Check secondary structure (floors, walls & roofs) for excessive
3 damage. Check drainage holes and internal cargo tie-down cleats
or rings for damage.
Check doors, frames, seals, hinges and locks for freedom of
4
operation and alignment.
If fitted, check forklift pockets for corrosion, mechanical damage
and excessive deformation. Make sure the pocket size is 200mm x
5 90mm and they are 1050mm apart when measured from centre to
centre of the forklift pocket. The forklift pockets shall have closed
tops.
6 Check markings on the CCU.
Check the slings and shackles with their respective checklist and
8 ensure satifactory remarks. BS EN 13414-1 and BS EN 13889
shall be the standard used for sling and shackles respectively.
NDT (MPI) should be conducted on the pad eyes before and after
9
a proofload test.
Should a load test be required, the load test procedure for CCU
10
(BS EN 12079), should be followed.
A stamped data plate should be attached to units that are OK. The
11
details on the data plate should be according to the procedure.
Signature
Company Appointed Examiner
Name: