Procedure

A) Project setup

B. modeling the system / laying out the network

C. Date entry

D. running the model

Table 1: reservoir

Reservoir Elevation (m) Zone


R-1 198 Connection zone

Table 2 Tank data

Tank Zone section Max Initial Min Base Diameter


elev elev elev elev
T-1 Zone-1 Const 226m 225m 220 200 8m
area

Table 3 pump data

Head Discharge Pump Elevation Pump type


(m) (1/min) (m)
Shutof 30 0 Pmp-1 193 3 point
Design 27.4 3800
Max 24.8 7500
operating

Table 4 pump data

Valve Elevation Diameter status settings Pressure


(mm) (kpa)
pRv-1 165 150 active pressure 390

Table 5 junction node data

Junction Ground elevation Zone Demand (1/min)


(m)
j-1 184 Zone-1 38
j-2 185 Zone-1 31
j-3 184 Zone-1 34
j-4 183 Zone-1 38
j-5 185 Zone-1 350
j-6 165 Zone-1 356

Table 6; pipe data

Pipe Material Diameter (mm) Length (m)


p-1 Ductile iron 1000 0.01
p-2 Ductile iron 150 58.5
p-3 Ductile iron 150 555.5
p-4 Pvc 150 336.5
p-5 Ductile iron 150 512.5
p-6 Ductile iron 150 343.5
p-7 Pvc 150 400
p-8 Ductile iron 150 500
p-9 Ductile iron 150 31
p-10 Ductile iron 150 100

Extended period simulation

Table 7; Residential and commercial

Pattern data

Time from start Residential Commercial


(hr) multiplier multiplier
3 o.4 0.6
6 1 o.8
9 1.3 1,6
12 1.2 1.6
15 1.2 1.2
18 1.6 0.8
21 0.8 0.6
24 0.5 0.4

Table 8: demand pattern

Junction Residential Commercial


demand (1/min) demand (1/min)
j-1 23 15
j-2 23 8
j-3 23 11
J-4 23 15
j-5 350 O
j-6 280 76
At junction 6(j-6) , insert an additional firedemandof 2000 1/min for3-hour
Table 9:3-fire pattern

Time from start (hr) multiplier


18 1
21 0
24 0

Scenario managamentd

Demand alternative (40001/min fire flow at j-)(change from2000 to 40001/min)

Parent alternative average daily with 2001min fire flow

Child alternative 40001/min fire flow

Parent scenario: 20001/min 3-hour fire flow at j-6

Child scenario 40001/min fire flow at j-6

Calculate and compare

Physical alternative (pipe diameter change from 150 mm to 200mm)

Child scenario p-8 and p-9 set to 200mm

Child alternative p-8 and p-9 set to 200mm

Reporting Resulting

Reports, display and print information on any or all elements in the system.
tabular Reports (flex table ), for viewing editing, and presentation fo
selected data and elements in tabular format
.profiles, to graphically show , in profile view, how a selected attribute,
such as hydraulic grade, varies a long an interconnected series of pipe s
Contouring to show how a selected attribute, such as pressure , varies
throughout the distribution system
Element annotation, for dynamic presentation of the values of user
selected variable s in the plane view
Color coding, assigns colors based on ranges of values to elements
Working with Data from external sources

Importing data from a standard database or spreadsheet


importing shape -file data
converting CAD drawing Entities