You are on page 1of 17

Multiphase Pump Technology

LEISTRITZ PUMPEN GMBH

Introduction in Leistritz
Multiphase Pump Technology
Part II

Seite1 Stand: 06.08.02


Multiphase Pump Technology
LEISTRITZ PUMPEN GMBH

General Design:

Seite2 Stand: 06.08.02


Multiphase Pump Technology
LEISTRITZ PUMPEN GMBH

Design Features:
The pump design can be adapted to suit each Application

Limited Shaft Deflection (1/2 radial clearance)

Rigid Rotor Design


Three Seal Types available depending on Application

Provides High Operational Safety

Seite3 Stand: 06.08.02


Multiphase Pump Technology
LEISTRITZ PUMPEN GMBH

Limited Shaft Deflection:

No Contact of Pump Internals under all Operation Conditions

Low bending Stress avoid risk of rotor rupture

Smaller internal Clearances required thus higher Efficiency

Seite4 Stand: 06.08.02


Multiphase Pump Technology
LEISTRITZ PUMPEN GMBH

Rigid Rotor Design:

Rotor machined out of


one Piece
Short Bearing Span

No additional Support between Rotor and Casing required

High Torque Capability

High critical Speed (>10000 rpm)

Seite5 Stand: 06.08.02


Multiphase Pump Technology
LEISTRITZ PUMPEN GMBH

Mechanical Seal Design:

Single Seal GVF up to 80%


limited gas slug length
viscosity up to 500 cSt
low solid content
Single Seal with GVF up to 100%
Throttle Bushing average gas slug length
viscosity up to 500 cSt
Low Solid Content

Double Seal GVF up to 100%


no restriction of gas slug length
all viscosities
high solid content

Seite6 Stand: 06.08.02


Multiphase Pump Technology
LEISTRITZ PUMPEN GMBH

Single Seal
seal faces are lubricated
by the multiphase fluid

Capabilities
GVF up to 80%
limited gas slug length
viscosity up to 500 cSt
low solid content

Seite7 Stand: 06.08.02


Multiphase Pump Technology
LEISTRITZ PUMPEN GMBH

MPP-Unit with Single Seals

Seite8 Stand: 06.08.02


Multiphase Pump Technology
LEISTRITZ PUMPEN GMBH

Double Seal
seal faces are lubricated
by external flush fluid

Capabilities
GVF up to 100%
no limitation in gas
slug length
all viscosities
high solid content

Seite9 Stand: 06.08.02


Multiphase Pump Technology
LEISTRITZ PUMPEN GMBH

MPP-Unit with Double Seals

Seite10 Stand: 06.08.02


Multiphase Pump Technology
LEISTRITZ PUMPEN GMBH

Single Seal with Throttle bushing

seal faces are lubricated


by the liquid phase
of the multiphase fluid

Capabilities
GVF up to 100%
increased gas slug length
viscosity up to 500 cSt
low solid content

Seite11 Stand: 06.08.02


Multiphase Pump Technology
LEISTRITZ PUMPEN GMBH

MPP-Unit with Recirculation System

Seite12 Stand: 06.08.02


Multiphase Pump Technology
LEISTRITZ PUMPEN GMBH

Flow vs. Differential Pressure

Seite13 Stand: 06.08.02


Multiphase Pump Technology
LEISTRITZ PUMPEN GMBH

Power vs. Differential Pressure

Seite14 Stand: 06.08.02


Multiphase Pump Technology
LEISTRITZ PUMPEN GMBH

Total Efficiency vs. Differential Pressure

Seite15 Stand: 06.08.02


Multiphase Pump Technology
LEISTRITZ PUMPEN GMBH

Slug Flow

Seite16 Stand: 06.08.02


Multiphase Pump Technology
LEISTRITZ PUMPEN GMBH

How to select a MPP ?

1. Treat gas as equivalent liquid volume

2. Re-calculate gas volume to pump inlet


conditions

3. Add gas flow to oil and water flow


to get the total inlet volume

4. With the obtained total inlet volume and the differential pressure
required select pump size out of the performance diagrams

Seite17 Stand: 06.08.02