You are on page 1of 6

Product Specification 108-79770

13 September 2007 Rev. A2

1
TYPEMODEL

1.1 2-1419128-9
OJE-SS-105HM,000

1.2
OUTLINE As per Customer Drawing sheet

1.3 S
CONTACT ARRANGEMENT

1.4
CONTACT MATERIAL Ag alloy

2
SAFETY STANDARD

2.1
Conform with Japan Product Safety Electrical Appliance & Materials law

2.2
FOREIGN STANDARD Recognized by

3
COIL RATING

3.1 DCV
RATED VOLTAGE

3.2
COIL RESISTANCE

3.3 W
NORMINAL OPERATING POWER about 0.45W

3.4
MAX. ALLOWABLE COIL VOLTAGE 130% of rated coil voltage (at 23)

213-8535 3-5-8 1 of 6
Tyco Electronics EC K.K. (3-5-8 Hisamoto Takatsu-ku Kawasaki, 213-8535)
This document is subject to change. Call local Tyco Electronics for the latest
revision.
Copyright 2007 by Tyco Electronics EC K.K. All rights reserved.
* : Trademark
Product Specification 108-79770

4
CONTACT SPECIFICATION

4.1
CONTACT RATING Load Inrush current curry current Cut off current

(A)ACV
4.2
RATED CONTACT CURRENT

4.3
MAX. CONTACT CAPACITY

4.4 (
MIN. APPLICABLE LOAD (reference)

5
PERFORMANCE

5.1 DC6V A
CONTACT RESISTANCE 100 Max. (at initial stage) voltage drop test method 6VDC 1A

5.2 .
OPERATE VOLTAGE 3.75VDC Max. of rated voltage. (at 23)

5.3 .
RELEASE VOLTAGE 0.25VDC Min. of rated voltage. (at 23)

5.4
OPERATE TIME 10ms Max. at rated voltage.

5.5
RELEASE TIME 5ms Max. at rated voltage

5.6
ENDURANCE

(1) (A)
ELECTRICALLY Contact rate A: 100,000ops. Min. (10 ops/minute)

(2) 1,000 300


MECHANICALLY 10,000,000 ops. at no load. (300 ops./minute)

5.7 mA
DIELECTRIC STRENGHT (Leak current: 1mA)

(1) 750VAC 1 900VAC 1


BETWEEN CONTACTS 750VAC for 1 minute or 900VAC for 1 second.

(2) 3,000VAC 1 3,600VAC 1


BETWEEN COIL TO CONTACTS 3,000VAC for 1 minute or 3,600VAC for 1 second.

5.8 500VDC 1,000M


INSULATION RESISTANCE Between contacts and coil to contact 1,000M Min. at 500VDC

5.9 5kV(1.2/50s)
SURGE RESISTIVENESS Between coil to contact. 5kV (1.2/50s)

Rev. A2 2 of 6
Product Specification 108-79770

5.10
TEMPERATURE RISE

(1)

COIL 55K Max. by resistance method when the rated current is provided to contact

and rated voltage is supplied to relay coil.

(2) A

CONTACT 60K Max. by temperature measuring method at Contact: 10A, Coil: rated voltage

5.11
VIBRATION

(1) 1.5mm 1055Hz 3 5


1ms
ERROR OPERATION No error operation than 1ms Max. when vibrate it from 3 directions for 5 minutes.

(Amplitude 1.5mm. 10 55Hz)

(2) 1.5mm 1055Hz 3 2



ENDURANCE No construction trouble when vibrate it from 3 directions for 2 hours.

(Amplitude 1.5mm. 10 55Hz)

5.12
SHOCK

(1) 98ms 11ms 3 3


ms
ERROR OPERATION No error operate by contact more than 1ms Max. when shocks it from 3 directions

3 times. (at Peak acceleration 98 m/s Duration 11ms.)

(2) 980ms 6ms 3 3



ENDURANCE No construction trouble when shocks is from 3 directions 3 times.

(at Peak acceleration 980 m/s Duration 6ms.)

5.13 5N 10

TERMINAL STRENGTH No construction and exterior trouble when pull and push into any terminals by 5N

for 10sec.

5.14 85 240 2

THERMAL PROOF Not any trouble on construction and characteristic when leave in 85 240h

After that, leave it in standard condition for 2 hours.

5.15 40 240 2

COLD PROOF Not any trouble on construction and characteristic when leave in -40 240h

After that, leave it in standard condition for 2 hours.

Rev. A2 3 of 6
Product Specification 108-79770

5.16 40 90RH 24 2
10M

HUMIDITY PROOF Insulation resistance 10M Min. Not any troubles on construction and

characteristic when leave in 40 90% 24h. After that, leave it in

standard condition for 2 hours.

5.17 (85) 0.5 (-40) 0.5 1


100 2

THERMAL SHOCK Not any troubles on construction and characteristic when leave it in -40 and 85

temp. room for 0.5 h each. That is one cycle. After 100 cycles has done, leave it on

standard condition for 2 hours.

5.18 3505 3 2605


10
SOLDERING THERMAL Not any troubles on construction and characteristic. When dipped into soldering

bath 3505 3sec. or 2605 10sec.

5.19 260 5
SOLDERABILITY Not any problems solder dipped at 260 5 sec.

6
STANDARDS TEST CONDITION

6.1
TEMPERATURE

6.2 RH
HUMIDITY

6.3
DIRECTON OF MEASUREMENT Terminals down position is standard position.

7
OPERATING CONDITION

7.1
TEMPERATURE (On conditions without freezing and dew condensation)

7.2 %RH
HUMIDITY

7.3
MOUNTING DIRECTION Terminal down position is standard position

Rev. A2 4 of 6
Product Specification 108-79770

8
STORAGE CONDITION

8.1
TEMPERATURE (On conditions without freezing and dew condensation)

8.2 RH
HUMIDITY

8.3
ENVIRONMENT

(1)
Store in locations where the product or container is not expose to corrosive gas such as hydrogen sulfide gas

or salty air.

(2)
Store in location where no visible dust exists.

(3)
Store in location not subject to direct sunlight.

9
OTHER

Rev. A2 5 of 6
Product Specification 108-79770

10
CHANGE PROFILE

A2 Logo Revise September 13, 2007


A1 Modify August 1, 2006
A Standard Temp.2023 July 27, 2006
O New Issue EC-FK00-0104-04 June 29, 2004
LTR REVISION RECORD ECN DATE

Rev. A2 6 of 6