All elements of the existing structure subject to additional loadings to be exposed for Lintels & steelwork: - Unless otherwise stated lintels to be Catnic combined steel to BS5977
inspection by the Building Inspector. (sizes as recommended by manufacturer). Provide min. 150mm end bearing where bearing is
less than 150mm concrete padstones are to be provided (size to suit load and detail). All lintel
backs and soffits to have a min half hour fire resistance and be insulated to prevent cold
All proprietary components used in the proposed works are to be installed in accordance with bridging where necessary. Where steel U.Bs are used they have to be settled to concrete
manufacturers directions Contractor to ensure that all instructions are obtained and adhered padstones or steel bearer plates each end. Half hour fire protection to steelwork.
to.
Damp proof courses: - Horizontal and vertical DPCs will comply with BS743
External walls and foundations: - The external walls are to be in a facing render to match
(pitch polymer) and be incorporated:-
existing comprising of 100mm blockwork Celcon or Thermalite to the external leaf with (a). Min. 150mm above ground to all load bearing walls, lapped with floor damp
1:1:6 cement/lime/sand.100mm cavity with 100mm Rockwool "full fill" DriTherm or other proof membrane.
approved insulation material. 100mm thermal insulating blockwork Celcon or Thermalite on (b). Vertical built into jambs of all external openings.
the inner leaf with mortar as before, 13mm thickness British Gypsum plaster, all to achieve a (c). Horizontally stepped to all external openings.
"U" value of 0.30.
Cavity wall insulation carried below DPC and overlapped by 150mm with floor insulation Pitch roof construction: - Concrete interlocking roof tiles to match existing in color
and to meet with roof insulation at top of wall. Cavity must not be closed at eaves with and style laid to gauge with 75mm head laps on 50x25mm tanilised softwood battens
blockwork. All cavity closers to be insulated. Insulation in accord with "robust construction secured with wire nails to BS5534. Bitumen reinforced sarking felt to BS747 type 1F
details. (150mm laps) laid horizontally over specified rafters. 100x47mm SC3 rafters at
450mm c/c secured to a 100x50mm softwood wall plate strapped down to the
All external and internal leafs are to be securely retained by approved stainless steel wall ties external cavity walls. 100mm quilt insulation laid between the ceiling joists with
to BS1243 positioned 450mm apart vertically and 750mm horizontally. Wall ties at openings 175mm insulation cross laid over to give total thickness of 275mm glass fiber quilt
spaced not more than 300mm vertically provided within 225mm from sides of opening at insulation. Ceiling joists 122x47mm SC3 at 450 c/c.12.5mm Gyproc Duplex
unbonded jambs. plasterboard and skim finish ceiling. All provide "U" value of 0.16 or better. A
proprietary eaves vent system comprising 10mm continuous strip ventilator secured
Lean mix cavity fill to all cavity walling terminating min. 225mm below lowest DPC level. to the outer edge of the 9mm Supalux soffit board, running the entire length of the
Cavity insulation to finish at same level as floor slab insulation. Below ground level both roof eaves. Eaves duct ventilation trays secured to the rafters to restrain the
leaves shall be built in trench-blocks or class "B" engineering brickwork. insulation quilt. All valleys to be lined with code 4 lead work on treated softwood
valleys boards. Where new roofs abut new or existing brickwork provide for code 4
Foundations in accordance with BS8004. All foundations subject to ground conditions to lead flashing stepped where required with patent cavity trays fitted over where
have at least 750mm cover below ground level. Minimum foundation depth in clay soil to be required. Horizontal and vertical straps for lateral support as described above
1000mm. Foundations shall be extended below pipe or ductwork penetrating walling. positioned at intervals not exceeding 1800mm.
Oversite concrete will be level with or above the finished ground level. Foundation design
must be approved by the BC officer subject to site investigation. Unstable load bearing strata Flat roof construction: - Three layers of built up roofing class 3 to BS747. The top
will necessitate separate structural design. layer to be mineral surfaced bituminous fully bonded to glass fiber based underfelt
(a). Concrete trench fill founds to all load bearing cavity walls to be min. 600x1000mm layer. Type 3G bottom layer to be
deep.
partially bonded to 105mm Kingspan Kooltherm K11 roof boards over joists or other
(b). Concrete strip founds to all singe skin load bearing walls to be min. 450x1000mm
deep. equal approved to provide a "U" value at 0.20 or better. Vapour barrier on 19mm
WBP plywood to BS1455 all laid to fails via softwood firrings. 170x47mm SC3 at
Solid floor slab: - 75mm concrete screed, on vapour barrier, on 70mm Kingspan insulation 450mm c/c softwood treated timber roof joists with min 100mm end bearing.
with a 25mm upstand of insulation provided to perimeter edges of floors, on 150mm re- 12.5mm Duplex Gyproc plasterboard and skim finish ceiling internally. Set to new
inforced concrete slab on 1200mm gauge DPM lapped to wall DPC. Sand blinding and and existing either via catnic type joist hangers or 100x50mm wall plates.
minimum 150mm clean compacted hardcore.
A lesser standard of insulation may be acceptable should problems be encountered with Lateral restraint to floor and roof: - All floors and roofs to be anchored by catnic
matching existing floor levels. Confirm with BC. metal anchors (30x5mm mild steel). Straps to be secured to timber and walls min
1000mm long at max 1200mm c/c (1800mm c/c in single story construction).