Professional Documents
Culture Documents
ISO 14692
1. Introduction
ISO (the International Organization for Standardization) is a worldwide network of
national standard institutes. The ISO 14692 standard is an international standard dealing
with the qualification, manufacturing, design and installation of GRE piping systems.
This document gives a brief summary of the ISO 14692 standard only and is not intended
to replace the ISO 14692 standard.
Trouble-
3. Install according to manufacturers standards and
free pipe
guidelines.
Installation
Figure 1. The key to success
Content
1. Introduction 1
2. What is ISO 14692? 2
3. Part 1: Vocabulary, symbols, applications and materials 3
4. Part 2: Qualification of components 3
5. Part 3: System design 5
6. Part 4: Fabrication, installation and operation 7
7. Conclusion 9
8. ISO in brief 9
9. References 9
10. Deviations list to the ISO quality program 10
A product sector contains all the items within its diameter and
Table 1. Overview of product sectors pressure range, the so called component variants. Component
variants are qualified by either two 1000 hr tests or through the
Diameter (mm) Pressure range (bar) scaling method.
0 - 50 50 - 100 100 -150 >
_ 150
25 - 250 A H N S For quality control, short term tests could be performed, if
250 - 400 B I O T required and agreed with the principal. These are done to
400 - 600 C J P establish a baseline value for quality control.
600 - 800 D K Q Other aspects to be considered are: the glass transition tem-
800 - 1200 E L R perature, the glass resin ratio and component dimensions.
These have to be determined from the replicate samples and
used by quality control during production as base line values.
The sum of all hoop stresses and the sum of all axial stresses
in any component in the piping system shall lie within the long-
term design envelope.
6.2.1 Inspection
It starts with checking the incoming goods
Check supplied quantity.
Check nominal dimensions of supplied material
Check supplied pressures class Photo 6. Typical work of a GRE pipe fitter
Perform a visual control of supplied material (transport
damage, impact) Training of pipe fitter
Check if storage is correct The quality of the joints is mainly dependent on craftsman-
Check availability of documentation (packing lists, ship of the pipe fitter. Therefore, the ISO 14692 demands
certification) that the qualification organization is independent of the
Handling and storage of the incoming goods organization that carries out the training. In the case of
Use the Ameron lifting, loading and unloading procedure. Ameron the independent organization is DNV. The training
Storage. Pay attention to the stacking of the pipe; consists of a theoretical and a practical part.
support width and stacking height, end protection of pipe The theoretical part will end with a written exam for which
and fittings. a 70% pass mark is required. The practical part will end
Preferably, pipes should be transported in containers or with making a joint that will be hydro-tested according the
crates. requirements of the ISO 14692. These tests are witnessed
Supporting
Follow the installation guides from the Manufacturer.
Other guidelines not different from the Ameron procedures
are given in the ISO 14692.
Installation
General requirements are given in the ISO 14692 for the
installation of GRP/GRE components such as bending,
bolt-torquing, tolerances, earthing of conductive piping, joint
selection, quality control, etc.
Most important point is that all piping shall be installed so that
they are stress-free.
8. ISO in brief
ISO (International Organization for Standardization) is a global ISO a non-governmental organization, is a federation of
network that identifies what International Standards are national standards, bodies of over 149 countries, one per
required by business, government and society, develops them country, from all regions of the world, including developed,
in partnership with the sectors, that will put them in use, developing and transitional economies.
adopts them by transparent procedures based on national
input and delivers them to be implemented worldwide.
9. References
ISO 14692-1 Petroleum and natural gas industries
Glass-reinforced plastics (GRP) piping Part 1:
Vocabulary, symbols, applications and materials;
ISO 14692-2 Petroleum and natural gas industries
Glass-reinforced plastics (GRP) piping Part 2:
Qualification and manufacture;
ISO 14692-3 Petroleum and natural gas industries
Glass-reinforced plastics (GRP) piping Part 3:
System design;
ISO 14692-4 Petroleum and natural gas industries
Glass-reinforced plastics (GRP) piping Part 4:
Fabrication, installation and operation.
8.3.2.4 Retesting: by failures of one of both retested compo- Only the failed components will be rejected. In case of
nents, the whole lot to the latest successful hydrotest rejected components, 100% will be conducted until the
shall be rejected. infected range has been determined
8.3.3 Degree of cure: DSC according to ISO 11357-2 According to API 15LR.
Determination of a QC baseline on base-resin or
component. Min. acc. = 130 / 140 dgr.C
Frequency of 1% on c.p.
Once per shift
8.3.4 Short-term burst test: Agreed with principal Once per three months
8.3.6 Glass content in accordance with ISO 1172 at a In accordance with ASTM-D-2584 at a frequency of
frequency of 1% of c.p. once a week random two types.
Acceptance: 70-82% for filament wound pipe Acceptance: 65-77% for filament wound pipe
65-75% filament wound fittings 55-65% for filament wound fittings
50-65% hand-lay-up fittings
8.3.8.2 The following dimensions shall be determined in Ameron conducts 100% inspection on outside diameter
& accordance with ASTM D-3567 for 1% of pipe and of pipe. Reinforced wall thickness is automatically
8.3.8.3 each fitting: determined by using fixed inside diameter. All dimensions
a) Internal diameter and tolerances are in accordance with Ameron product
b) Outside diameter drawings.
c) Mass
d) Minimum total wall thickness
e) Reinforced wall thickness
f) Laying length
8.3.11 Retest: by failures of one of both retested compo- Only the failed components will be rejected.
nents, the whole batch to the latest successful test To avoid rejecting good products, Ameron will test all
shall be rejected. products to trace all infected products.
9.1 Markings shall be applied on the pipe and fittings Pipes 3 locations,
within 1 m of the end. Fitting one location
9.2 All pipe and fittings shall be permanently marked with Pipes and fittings will be marked with:
details as in Para 9.2: a) Manufacturers name
a) Manufacturers name b) Not
b) Product line designation c) Qualified pressure
c) Qualified pressure d) Not
d) Temperature at which qualified pressure is e) System design pressure
determined (default is 65C). f) System design temperature
e) System design pressure g) Nominal diameter
f) System design temperature h) Manufacturers identification code
g) Nominal diameter i) Not
h) Manufacturers identification code
i) Limitations or referenced to installation requirements:
permissible bolt torque, portable water (yes/no), elec-
trical conductivity and fire performance classification.
11.4.4 Production quality control reports in acc. 8.4 shall be Special Manufacturing Record Book
provided within five working days or other agreed
period