You are on page 1of 24

High Performance Lamps

ESR3 Prototypes & Results

R&D Bulb team


LED Lamps
April 29 , 2016

1
Lamp proposal

2 April 29, 2016 - LED Lamps - Confidential -


ESR3 Samples shipped 2016.04.29

3000K MR16
30pcs Candle 200lm Bulb A60 400lm Bulb A60 600lm
1W 3000K 2W 3000K 3W 3000K
25pcs 25pcs 25pcs

6500K MR16
20pcs Candle 200lm Bulb A60 400lm Bulb A60 600lm
1W 6500K 2W 6500K 3W 6500K
DHL: 2108729405 25pcs 25pcs 25pcs
3 April 29, 2016 - LED Lamps - Confidential -
High Performance Lamps
LED GLASS Filament Candle & Bulbs

4 April 29, 2016 - LED Lamps - Confidential -


Bulbs:
Key specification targets
Item CANDLE BULB BULB Tolerances Comments
Type & Size B38-E14-Cl A60-E27-Cl A60-E27-Cl IEC Outlines

Application Indoor Indoor Indoor Indoor


Non-dimmable Non-dimmable Non-dimmable Non-dimmable
Voltage & Hz 220V~240Vac 220V~240Vac 220V~240Vac 220V~240Vac
50/60Hz 50/60Hz 50/60Hz 50/60Hz
Power Typ. 1.0 W 2.0 W 3. 0 W 10%

Power factor >0.5 >0.5 >0.5 No spec as W< 5W

Flux 200 lm 400 lm 600 lm 10%

Efficacy 200 lpw 200 lpw 200 lpw TARGET

CCT 3000K & 6500K 3000K & 6500K 3000K & 6500K Within ANSI

Color 6SDCM 6SDCM 6SDCM


Consistency
Switching cycle 100K 100K 100K

CRI R9 80 & R9>0 80 & R9>0 80 & R9>0 Min 77 R9=0

Lifetime 15khs @ free air 15khs @ free air 15khs @ free air
(L70/B50)
Warranty 1 year (B1: 2khs) 1 year (B1: 2khs) 1 year (B1: 2khs)

Approbation RoHS/REACH/PVC RoHS/REACH/PVC RoHS/REACH/PVC RoHS/REACH/PVC

5 April 29, 2016 - LED Lamps - Confidential -


LED GLASS Filament Candle & Bulbs
Efficacy (lm/W) overview of ESR3

2W A60 type is the carrier for


filament strip design.

1W Candle might have some


losses due the base/
configuration

3W A60 bulb type might have


some losses due to internal
reflections/ absorption as many
strips.

(All LED strips are driven at same


Vf)

200 lm/W: Getting close.

6 April 29, 2016 - LED Lamps - Confidential -


LED GLASS Filament Candle & Bulbs
CRI & R9 overview of ESR3

Slight adjustments in CRI and R9


can allow balancing efficacy
versus color rendition.

7 April 29, 2016 - LED Lamps - Confidential -


LED GLASS Filament Candle & Bulbs
Candle 1W 200lm 6500K (ESR3)
Candle 1W-200lm-6500K
P Flux Efficacy CCT x y CRI R9
(W) (lm) lm/W (K)
n 32 32 32 32 32 32 32 32
Average 1.01 193 190.6 6871 0.3074 0.3219 82.9 16.7
Std Dev. 0.02 4 2.5 80 0.0010 0.0016 0.3 1.3
Min 0.98 184 183.6 6762 0.3036 0.3154 82.4 14.3
Max 1.05 200 194.4 7193 0.3088 0.3244 83.6 20.4

CIE 1931 (x, y) diagram


0.352

0.342

0.332

y
0.322 Planckian locus

Center Point
0.312 6500K

Data
0.302
0.277 0.287 0.297 0.307 0.317 0.327 0.337

8 April 29, 2016 - LED Lamps - Confidential -


LED GLASS Filament Candle & Bulbs
Bulb A60 2W 400lm 6500K (ESR3)
Bulb A60 2W-400lm-6500K
P Flux Efficacy CCT x y CRI R9
(W) (lm) lm/W (K)
n 30 30 30 30 30 30 30 30
Average 2.05 401 195.2 6521 0.3122 0.3301 82.6 12.1
Std Dev. 0.02 5 1.5 49 0.0007 0.0013 0.3 1.3
Min 2.01 393 192.5 6436 0.3100 0.3264 82.2 9.2
Max 2.11 413 198.4 6673 0.3136 0.3330 83.2 14.5

CIE 1931 (x, y) diagram


0.352

0.342

0.332

y
0.322 Planckian locus

Center Point
0.312 6500K

Data
0.302
0.279 0.289 0.299 0.309 0.319 0.329 0.339

9 April 29, 2016 - LED Lamps - Confidential -


LED GLASS Filament Candle & Bulbs
Bulb A60 3W 600lm 6500K (ESR3)
Bulb A60 3W-600lm-6500K
P Flux Efficacy CCT x y CRI R9
(W) (lm) lm/W (K)
n 31 31 31 31 31 31 31 31
Average 3.10 594 191.5 6300 0.3160 0.3338 82.5 11.1
Std Dev. 0.03 6 1.6 37 0.0006 0.0010 0.2 0.8
Min 3.04 580 188.9 6192 0.3147 0.3319 82.1 9.3
Max 3.16 604 195.9 6376 0.3179 0.3364 83.2 13.5

CIE 1931 (x, y) diagram


0.352

0.342

0.332

y
0.322 Planckian locus

Center Point
0.312 6500K

Data
0.302
0.280 0.290 0.300 0.310 0.320 0.330 0.340

10 April 29, 2016 - LED Lamps - Confidential -


LED GLASS Filament Candle & Bulbs
Candle 1W 200lm 3000K (ESR3)
Candle 1W-200lm-3000K
P Flux Efficacy CCT x y CRI R9
(W) (lm) lm/W (K)
n 28 28 28 28 28 28 28 28
Average 1.03 200 194.2 3205 0.4216 0.3956 82.5 3.4
Std Dev. 0.02 3 1.7 9 0.0007 0.0007 0.1 0.4
Min 1.00 194 191.2 3184 0.4204 0.3943 82.3 2.6
Max 1.06 206 196.8 3218 0.4231 0.3969 82.7 4.2

0.439
CIE 1931 (x, y) diagram
0.429

0.419

0.409

y
0.399
Planckian locus
0.389
Center Point
3000K
0.379
Data
0.369
0.389 0.399 0.409 0.419 0.429 0.439 0.449 0.459 0.469

11 April 29, 2016 - LED Lamps - Confidential -


LED GLASS Filament Candle & Bulbs
Bulb A60 2W 400lm 3000K (ESR3)
Bulb A60 2W-400lm-3000K
P Flux Efficacy CCT x y CRI R9
(W) (lm) lm/W (K)
n 30 30 30 30 30 30 30 30
Average 2.18 426 195.4 3132 0.4277 0.4004 81.8 0.7
Std Dev. 0.32 59 1.8 30 0.0022 0.0014 0.2 0.6
Min 2.02 398 191.0 3008 0.4254 0.3988 81.1 -1.6
Max 3.13 601 198.4 3160 0.4354 0.4065 82.1 1.6

CIE 1931 (x, y) diagram


0.430

0.420

0.410

y
0.400

Planckian locus
0.390
Center Point
3000K
0.380
Data
0.370
0.393 0.403 0.413 0.423 0.433 0.443 0.453 0.463 0.473

12 April 29, 2016 - LED Lamps - Confidential -


LED GLASS Filament Candle & Bulbs
Bulb A60 3W 600lm 3000K (ESR3)
Bulb A60 3W-600lm-3000K
P Flux Efficacy CCT x y CRI R9
(W) (lm) lm/W (K)
n 30 30 30 30 30 30 30 30
Average 3.13 591 188.5 3050 0.4345 0.4051 81.3 -0.2
Std Dev. 0.04 13 2.6 24 0.0013 0.0022 0.2 0.9
Min 3.04 546 179.4 3003 0.4322 0.4002 80.9 -2.1
Max 3.31 635 192.7 3087 0.4372 0.4078 81.6 1.1

CIE 1931 (x, y) diagram


0.430

0.420

0.410

y
0.400

Planckian locus
0.390
Center Point
3000K
0.380
Data
0.370
0.393 0.403 0.413 0.423 0.433 0.443 0.453 0.463 0.473

13 April 29, 2016 - LED Lamps - Confidential -


LED GLASS Filament Candle & Bulbs
Candle 1W 200lm 3000K & 6500K (ESR3)

Light distribution and light spectrum

14 April 29, 2016 - LED Lamps - Confidential -


LED GLASS Filament Candle & Bulbs
Bulb A60 2W 400lm 3000K & 6500K (ESR3)

Light distribution and light spectrum

15 April 29, 2016 - LED Lamps - Confidential -


LED GLASS Filament Candle & Bulbs
Bulb A60 3W 600lm 3000K & 6500K (ESR3)

Light distribution and light spectrum

16 April 29, 2016 - LED Lamps - Confidential -


LED GLASS Filament Candle & Bulbs
Power factor(ESR3)

Power factor, cos , THD


Lamp PF Cos THD

Candle 1W 200lm 3000K 0.5234 0.7096 88.2%

Candle 1W 200lm 6500K 0.5234 0.7096 88.2%

Bulb A60 2W 400lm 3000K 0.5285 0.7230 89.6%

Bulb A60 2W 400lm 6500K 0.5285 0.7230 89.6%

Bulb A60 3W 600lm 3000K 0.5327 0.7114 86.12

Bulb A60 3W 600lm 6500K 0.5327 0.7114 86.12

The Power Factor defines the difference in wave shapes of voltage (V) and current (I) consumed by the device, versus the
generated voltage and current in a power plant. The Power Factor is a function of the Displacement Factor (cos ) and the
Total Harmonic Distortion (THD):

Only the Displacement Factor (cos ) has an impact on the efficiency of the grid. The ideal value is cos = 1
In most countries, for LED lamps having a power between 5W and 25W, a power factor of 0.5 is specified or
recommended. Below 5W, usually there is no requirement, while IEC 62612 recommends a > 0.4
(Refer to previous communication about the power factor).

17 April 29, 2016 - LED Lamps - Confidential -


High Performance Lamps
MR16 Reflector

18 April 29, 2016 - LED Lamps - Confidential -


MR16 Reflector:
Key specification targets
Item MR16 6500K MR16 3000K Tolerances Comments
Type & Size MR16 MR16

Application Indoor Indoor Indoor


Non-dimmable Non-dimmable Non-dimmable
Voltage & Hz 12V 12V 12V

Power Typ. 3.0 W 3.0 W 10%

Flux 400 lm 420 lm 10%

Efficacy 140 lpw 140 lpw TARGET

Beam angle 36 36

MBCP (cd) 800 850

CCT 6500K 3000K Within ANSI

Color 6SDCM 6SDCM


Consistency
Switching cycle 100K 100K
CRI R9 80 & R9>0 80 & R9>0 Min 77 R9=0
Lifetime 25khs @ free air 25khs @ free air
(L70/B50)
Warranty 1 year (B1: 2khs) 1 year (B1: 2khs)
Approbation RoHS/REACH/PVC RoHS/REACH/PVC RoHS/REACH/PVC
19 April 29, 2016 - LED Lamps - Confidential -
MR16 Reflector
MR16 3W-400lm-6500K (ESR2)

MR16 3W-400lm-6500K
P Flux Efficacy CCT x y CRI R9
(W) (lm) lm/W (K)
n 5 5 5 5 5 5 5 5
Average 3.12 427 136.9 6279 0.3164 0.3341 81.8 5.0
Std Dev. 0.07 9 3.6 68 0.0012 0.0013 0.3 0.8
Min 3.06 415 133.6 6170 0.3153 0.3330 81.5 3.8
Max 3.24 437 142.9 6337 0.3183 0.3363 82.3 6.1

CIE 1931 (x, y) diagram


0.352

0.342

0.332
y

0.322 Planckian locus

Center Point
0.312 6500K

Data
0.302
0.280 0.290 0.300 0.310 0.320 0.330 0.340

20 April 29, 2016 - LED Lamps - Confidential -


MR16 Reflector
MR16 3W-400lm-3000K (ESR2)

MR16 3W-400lm-3000K
P Flux Efficacy CCT x y CRI R9
(W) (lm) lm/W (K)
n 5 5 5 5 5 5 5 5
Average 3.12 414 133.0 2989 0.4374 0.4036 82.7 6.8
Std Dev. 0.12 21 2.3 19 0.0011 0.0010 0.1 0.8
Min 3.01 388 129.0 2975 0.4357 0.4025 82.6 6.1
Max 3.30 443 134.4 3021 0.4387 0.4050 82.9 7.9

CIE 1931 (x, y) diagram


0.430

0.420

0.410
y

0.400

Planckian locus
0.390
Center Point
3000K
0.380
Data
0.370
0.393 0.403 0.413 0.423 0.433 0.443 0.453 0.463 0.473

21 April 29, 2016 - LED Lamps - Confidential -


MR16 Reflector
Typical beam distribution

Beam measurement:
12V-MR16-3W-400lm-3000K
P 1 2 MBCP
(W) (0-180) (90-270) (cd)
n 5 5 5 5
Average 3.10 30.22 30.40 846
Std Dev. 0.14 0.27 0.29 29
Min 3.00 29.80 30.10 808
Max 3.30 30.50 30.80 885

12V-MR16-3W-400lm-6500K
P 1 2 MBCP
(W) (0-180) (90-270) (cd)
n 5 5 5 5
Average 3.14 29.72 29.52 888
Std Dev. 0.05 0.30 0.59 29
Min 3.10 29.30 28.60 863
Max 3.20 30.00 30.10 935

22 April 29, 2016 - LED Lamps - Confidential -


MR16 Reflector
Key ETS transformer compatibility check:

Results with different Vin (1lamps)


Brand Model Min Load Max Load 198V 220V 264V
ET-E60 20W 60W PASS PASS PASS
ET-E105 50W 105W PASS PASS PASS
ET-S60 20W 60W PASS PASS PASS
Philips
ET-K50 50W PASS PASS PASS
ET-C60(10#) 20W 60W PASS PASS PASS
ET-E10LED 10W PASS PASS PASS
ECO-ET 60 20W 60W flicker
ET-P 60 20W 60W PASS PASS PASS
Osram
Redback 60VA 20W 60W PASS PASS PASS
PARROT 70 PASS PASS PASS
VIPER 60W PASS PASS PASS
Tridonic Speedy TE-0050 20W 50W flicker
POSSUM 60W flicker
NVC ET60E 20W 60W PASS PASS PASS
TCL ET60H 20W 60W PASS PASS PASS
OPPLE DB602 20W 60W PASS PASS PASS
LONON LNDET-50 20W 50W PASS PASS PASS

23 April 29, 2016 - LED Lamps - Confidential -


April 24
29, 2016 - LED Lamps - Confidential -

You might also like