Professional Documents
Culture Documents
Date : 05-May-16
Part : UG Swimming Pool Number: Element :
Project :
a) Material Proerties
fcu : 40 MPa (28 days compressive cube strength of concrete)
fy : 500 MPa (Characteristic steel strength)
3
wc : 25 kN/m (unit wt. of concrete)
2
Soil qallow : 350 kN/m (Net Safe bearing capacity of soil)
3
s : 18 kN/m (unit wt. of soil)
w : 10 kN/m3 (unit wt. of water)
: 27 deg (angle of internal friction of soil)
: 0.5 (Conc. friction factor)
Depth of foundation : 1.2 m (Top of footing)
b) Loading
Soil Pressure
Rankins coefficient ka : (1-sin)/(1+sin)
: 0.38
Ht. of RT wall Hs : 1.20 m
Water Pressure
max water level Hw : 1.20 m
Date : 05-May-16
Part : UG Swimming Pool Number: Element :
Project :
c) BM Calculation
Max. ht. of wall h : 1.50 m
Pa : 14.19 kPa (with load factor 1.4)
Surcharge PL : 7.26 kPa (with load factor 1.6)
BM : Pa*1/3h + PL*h2/2
: 35.85 kNm/m (Ultimate load)
: 24.88 kNm/m (Service load)
Reinforcement required
Wall thickess t : 300 mm
Effective depth of footing d : 242 mm
Along Length
bx : 1000 mm
Mux : 35.8 kNm
zx : 237.8 mm
but not greater than, 0.95d 0.95d : 229.9 mm
z : lesser of {237.81, 0.95 d}
zx : 229.9 mm
Required reinforcement for the BM,
As,req : Mu/0.87Fyz
2
Asx,req : 358.5 mm