You are on page 1of 6

www.hilti-me.com Profis Anchor 2.6.

4
Company: Page: 1
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 3/31/2016
E-Mail:

Specifier's comments:

1 Input data
Anchor type and diameter: HVZ M16x125
Seismic/Filling set or any suitable annular gap filling solution
Effective embedment depth: hef = 125 mm, hnom = 145 mm
Material: 8.8
Evaluation Service Report: ETA 03/0032
Issued I Valid: 6/4/2013 | 6/4/2018
Proof: SOFA design method + fib (07/2011) - after ETAG testing
Stand-off installation: eb = 0 mm (no stand-off); t = 15 mm
Anchor plate: Custom; E = 205000.00 N/mm2; fyk = 275.00 N/mm2; gMs = 1.000
lx x ly x t = 250 mm x 250 mm x 15 mm; (Recommended plate thickness: calculated (11 mm))
Profile: Pipe; (L x W x T) = 100 mm x 100 mm x 6 mm
Base material: cracked concrete, C30/37, fc = 30.00 N/mm2; h = 300 mm, Temp. short/long: 30/40 C
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: no reinforcement or reinforcement spacing >= 150 mm (any ) or >= 100 mm ( <= 10 mm)
with longitudinal edge reinforcement d >= 12 + close mesh (stirrups, hangers) s <=

Geometry [mm] & Loading [kN, kNm]

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti-me.com Profis Anchor 2.6.4
Company: Page: 2
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 3/31/2016
E-Mail:

2 Load case/Resulting anchor forces y


Load case: Design loads 3 4

Anchor reactions [kN]


Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y
1 8.750 3.824 0.750 3.750
2 8.750 3.824 0.750 3.750 x
Tension
3 8.750 3.824 0.750 3.750
4 8.750 3.824 0.750 3.750
max. concrete compressive strain: - []
max. concrete compressive stress: - [N/mm2]
resulting tension force in (x/y)=(0/0): 35.000 [kN]
resulting compression force in (x/y)=(0/0): 0.000 [kN] 1 2

3 Tension load SOFA (fib (07/2011), section 10.1)


Load [kN] Capacity [kN] Utilization bN [%] Status
Steel Strength* 8.750 60.000 15 OK
Pullout Strength* N/A N/A N/A N/A
Concrete Breakout Strength** 35.000 86.069 41 OK
Splitting failure** N/A N/A N/A N/A
* anchor having the highest loading **anchor group (anchors in tension)

3.1 Steel Strength


NRk,s [kN] gM,s NRd,s [kN] NSd [kN]
90.000 1.500 60.000 8.750

3.2 Concrete Breakout Strength


Ac,N [mm2] A0c,N [mm2] yA,N ccr,N [mm] scr,N [mm]
308025 140625 2.190 188 375
ec1,N [mm] yec1,N ec2,N [mm] yec2,N ys,N yre,N k1
0 1.000 0 1.000 1.000 1.000 7.700
N0Rk,c [kN] gM,c NRd,c [kN] NSd [kN]
58.941 1.500 86.069 35.000

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti-me.com Profis Anchor 2.6.4
Company: Page: 3
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 3/31/2016
E-Mail:

4 Shear load SOFA (fib (07/2011), section 10.2)


Load [kN] Capacity [kN] Utilization bV [%] Status
Steel Strength (without lever arm)* 3.824 40.800 10 OK
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout Strength** 15.297 172.139 9 OK
Concrete edge failure in direction ** N/A N/A N/A N/A
* anchor having the highest loading **anchor group (relevant anchors)

4.1 Steel Strength (without lever arm)


VRk,s [kN] gM,s VRd,s [kN] VSd [kN]
51.000 1.250 40.800 3.824

4.2 Pryout Strength


Ac,N [mm2] A0c,N [mm2] yA,N ccr,N [mm] scr,N [mm] k4
308025 140625 2.190 188 375 2.000
ec1,V [mm] yec1,N ec2,V [mm] yec2,N ys,N yre,N
0 1.000 0 1.000 1.000 1.000
N0Rk,c [kN] gM,c,p VRd,c1 [kN] VSd [kN]
58.941 1.500 172.139 15.297

5 Combined tension and shear loads SOFA (fib (07/2011), section 10.3)
bN bV a Utilization bN,V [%] Status
steel 0.146 0.094 2.000 4 OK
concrete 0.407 0.089 1.500 29 OK
a a
bN + bV <= 1

6 Displacements (highest loaded anchor)


Short term loading:
NSk = 6.481 [kN] dN = 0.063 [mm]
VSk = 2.833 [kN] dV = 0.237 [mm]
dNV = 0.245 [mm]
Long term loading:
NSk = 6.481 [kN] dN = 0.231 [mm]
VSk = 2.833 [kN] dV = 0.355 [mm]
dNV = 0.424 [mm]

Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements
are valid without friction between the concrete and the anchor plate! The gap due to the drilled hole and clearance hole tolerances are not
included in this calculation!

The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!

7 Warnings
Load re-distributions on the anchors due to elastic deformations of the anchor plate are not considered. The anchor plate is assumed to be
sufficiently stiff, in order not to be deformed when subjected to the loading!

Input data and results must be checked for agreement with the
existing conditions and for plausibility!
The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
The design method fib (07/2011) assumes that no hole clearance between the anchors and the fixture is present. This can be achieved by
filling the gap with mortar of sufficient compressive strength (e.g. by using the HILTI Seismic/Filling set) or by other suitable means
The compliance with current standards (e.g. EC3) is the responsibility of the user
Checking the transfer of loads into the base material is required in accordance with fib (07/2011)!

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti-me.com Profis Anchor 2.6.4
Company: Page: 4
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 3/31/2016
E-Mail:

Fastening meets the design criteria!

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti-me.com Profis Anchor 2.6.4
Company: Page: 5
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 3/31/2016
E-Mail:

8 Installation data
Anchor plate, steel: Custom; E = 205000.00 N/mm2; fyk = 275.00 N/mm2 Anchor type and diameter: HVZ M16x125
Profile: Pipe; 100 x 100 x 6 mm Installation torque: 0.090 kNm
Hole diameter in the fixture: df = 18 mm Hole diameter in the base material: 18 mm
Plate thickness (input): 15 mm Hole depth in the base material: 145 mm
Recommended plate thickness: calculated (11 mm) Minimum thickness of the base material: 190 mm
Drilling method: Hammer drilled
Cleaning: Manual cleaning of the drilled hole according to instructions for use is required.

8.1 Recommended accessories

Drilling Cleaning Setting


Suitable Rotary Hammer Manual blow-out pump HVA square drive shafts
Properly sized drill bit Seismic/Filling set
Torque wrench
y

125 125

35
3 4

125
180

x
125

1 2
35

35 180 35

Coordinates Anchor [mm]


Anchor x y c-x c+x c-y c+y
1 -90 -90 - - - -
2 90 -90 - - - -
3 -90 90 - - - -
4 90 90 - - - -

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti-me.com Profis Anchor 2.6.4
Company: Page: 6
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 3/31/2016
E-Mail:

9 Remarks; Your Cooperation Duties


Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas
and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be
strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted
prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the
data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be
put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly
with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an
aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or
suitability for a specific application.
You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for
the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do
not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software
in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or
damaged data or programs, arising from a culpable breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

You might also like