Professional Documents
Culture Documents
Calibration Chart
Location
Tank No. :9
Product : MS
Calibrated On : 02.02.2007.
Notes :
The level of Datum plate of the tank immediately below the Gaugewell pipe should be
taken as zero depth in the calibration chart.
This calibration chart is valid upto 01.02.2012 or even earlier to the date of making
any addition or alteration in the tank or change its position.
Calibration chart table is set out to show litres at the intervals of 5.0 cms .Use fraction
part table for immediate dips to get accurate results.
Certified that calibration upto cone top for Bottom plate was physically done by filling water
through water meter.
895878
Addition , Deduction Tank No. 9
0 0-5 5.-10 10.-15 15.-20 20.-25 25-30 30-35 35-40 40-45 45-50
6233 9800 17577 16680 19001.487 19001.487 19001.487 19001.487 19001.487 19001.487 19001.487
1900 -0.236 -0.788 -0.788 4.700 1.270 3.820
-1.329 1.630 3.270 -0.788 5.220 4.240
1.650 3.300 3.270 -0.788 5.220
0.388 3.880 3.300 3.270 -0.788
-4.429 -4.429 3.880 3.300 3.270
-3.250 -3.610 -4.429 3.880 3.300
-3.610 -4.429 3.880
-3.610 -4.429
-3.610
6233 9800 17577 18580 19001.487 18999.922 18996.688 19003.110 19007.810 19009.600 19016.390
50-55 55-60 60-65 65-70 70-75 75-80 80-85 85-90 90-95 95-100 100-105
19001.487 19001.487 19001.487 19001.487 19001.487 19001.487 19001.487 19001.487 19001.487 19001.487 19001.487
4.240 4.240 4.240 4.240 4.240 4.240 4.240 4.240 4.240 4.240 4.240
4.240 4.240 4.240 4.240 4.240 4.240 4.240 4.240 4.240 4.240 2.970
5.220 5.220 5.220 5.220 5.220 5.220 3.133 -11.400 -20.360 -20.360 -20.360
-0.788 -0.788 -0.788 -0.788 -0.788 -0.788 -0.236 -0.970 -0.970 -0.970 -0.970
3.270 2.940 3.880 1.940 -4.429 -0.490 -0.970 -4.429 -4.429 -4.429 -4.429
3.300 0.990 -4.429 -4.429 -3.610 -4.429 -4.429 -3.610 -3.580 -6.400 -6.400
3.880 3.880 -3.610 -3.610 -3.610 -3.610 -3.610 -3.610 -3.610
-4.429 -4.429
-3.610 -3.610
19016.810 19014.170 19010.240 19008.300 19006.360 19005.870 19003.855 18989.558 18977.018 18974.198 18972.928
105-110 110-115 115-120 120-125 125-130 130-135 135-140 140-175 19001.4870 680-825 19003.5286
19001.487 19001.487 19001.487 19001.487 19001.487 19001.487 19001.487 175-180 19000.4950 825-830 19001.0550
0.424 -20.360 -20.360 -20.360 -20.360 -20.360 -8.960 180-375 19000.3870 830-975 18998.5800
-20.360 -0.490 -4.429 -4.429 -4.429 -4.429 -1.950 375-380 18998.1935 975-980 18998.1795
-0.970 -4.429 -6.400 -6.400 -6.400 -6.400 -2.820 380-525 18997.9521 980-1125 18997.2449
-4.429 -6.400 525-530 18998.7285 1125-1130 18997.4100
-6.400 530-675 18998.8160 1130-1275 18997.7947
-2.890 675-680 19003.0585
1 2 3 4 5 6 7 8 9
Avg.Ext.Circum. 3.1428 69.2200 69.2180 69.2010 69.1900 69.1860 69.1770 69.1620 69.1630 69.1580
Thickness 14.0 14.0 12.0 10.0 8.0 8.0 6.0 6.0 6.0
Thick 2 py t 0.087998 0.087998 0.075427 0.062856 0.050285 0.050285 0.037714 0.037714 0.000000
V.Jts. 0.012 0.012 0.012 0.012 0.012 0.012 0.012 0.012 0.012
Total Dedudction 0.099998 0.099998 0.087427 0.074856 0.062285 0.062285 0.049714 0.049714 0.012000
Avg.Int.Circum. 69.1200 69.1180 69.1136 69.1151 69.1237 69.1147 69.1123 69.1133 69.1460
Radius 6.2856 10.99656 10.99625 10.99554 10.99579 10.99715 10.99572 10.99534 10.9955 11.0007
Lit./5 Cms. 21.993 19002.06 19000.96 18998.53 18999.39 19004.10 18999.16 18997.82 18998.37 19016.36
CDW 0.576 19001.49 19000.39 18997.95 18998.82 19003.53 18998.58 18997.24 18997.79 19015.78
Lit / Cms. Avg. 3800.257 3800.297 3800.077 3799.590 3799.763 3800.706 3799.716 3799.449 3799.559 3803.157
Shell Height 201 200 150 150 152 151 150 151 150
C. Height 25.5 175.500 175.5 375.5 525.5 675.5 827.5 978.5 1128.5 1279.5 1429.5
Cap.Of shell 666952 760015 569939 569964 577707 573757 569917 573733 570474
Page 4/12
Unique Calibrators,Mumbai-Tel-022- 2498 1832
Hindustan Petroleum Corporation Limited. Tank No.
Discription
Dip Pipe 29.21 cms dia 0.27 Litres / 5 cms Comman dead wood
0.54 for 2 nos.
Temp. Sensor Pipe 2" 0.036 Litres / 5 cms comman dead wood
Central Roof drain pipe 0.7229 3.61 Ltr / 5 cm - 25.5 to 109 cms.
36.66 legth
Pipe inlet nozzle 47.5x28 1.04458 5.22 Ltr / 5 cm + 35.5 to 83.0 cms.
Pipe inlet nozzle 29*29 0.6605 3.3 Ltr / 5 cm + 27.5 to 56.5 cms.
Pipe inlet nozzle 32*26 0.6534 3.27 Ltr / 5 cm + 27.5 to 59.5 cms.
Pipe inlet nozzle 38*26 0.7759 3.88 Ltr / 5 cm + 29.5 to 67.5 cms.
Leg support
43 nos 4" sleeve 0.03 6.4 Ltr / 5 cm - 23.5 to 137.2 cms.
we will deduct 2 nos. gauge well pipe and 1 no temp sencor pipe throuout shell ht by 0.576 lit / 5 cms.
18999.922 Lit / 5 cm
18996.688 Lit / 5 cm
19003.110 Lit / 5 cm
19010.240 Lit / 5 cm
Unique Calibrators,Mumbai-Tel-022- 2498 1832 Pg 8/12
Hindustan Petroleum Corporation Limited Tank No. 9
19008.300 Lit / 5 cm
19006.360 Lit / 5 cm
19005.870 Lit / 5 cm
19003.855 Lit / 5 cm
18989.558 Lit / 5 cm
18977.018 Lit / 5 cm
18974.198 Lit / 5 cm
18972.928 Lit / 5 cm
18966.862 Lit / 5 cm
18969.808 Lit / 5 cm
18987.757 Lit / 5 cm
Hindustan Petroleum Corporation Limited.
2 No deduction for roof weight is to be made when the liquid is not touching the floating roof.
(a) when the roof is on LOW LEGS , the off float position is 137.2 cms. depth.
(b) when the roof is on HIGH LEGS, the off float position is 197.2 cms. depth.
3 (a) The fully floating position of the roof depends upon the gravity of the tank contents.
The following is the method for finding the fully floating positions of the roof.
Fully flaoting position of the roof = off float position in cms+Roof weight displacement in cms.
Roof weight in Kilograms 1
Roof weight displacement in cms. = --------------------------------------------- X----------------------------------------
Density of stock at tank temp. in Kgs./ Ltrs. Liters / cms. for the tank.
4 The roof is to be considered as partly submerged where the level is in between off float position and full float position
proportionate capacity due to roof weight is to be deducted when the roof is partly submerged.
DATA Gauge readings = 145.0 Tankcms. Temperature = 32 C Density of stock = 0.73 Kgs/ Ltrs.
69863
Now Approximate disp. = X (145-137.2) =
-------------------- 29648 Litres
18.38
Net volume for 145 cms at tank temperature = 546011-29648 516363 Ltrs
541015 Ltrs.
5 Volume obtained when roof is partly submerged as in (4) above are not accurate . The roof should, therefore, be always kept
either fully floating or completely - Off float by pushing water at the bottom.
6 The roof should always be maintained on Low legs while the tank is in service.
Pg 12/12