AUTOPIPE / CAESAR TRANSLATION

CONTENTS

AutoPIPE / Caesar Translation ...................................................... 1

Caesar Neutral File Versions ......................................................... 2

Transfering Caesar Model to AutoPIPE ........................................... 3

Transfer Large Caesar Models ....................................................... 9

AutoPIPE Configurable Mapping .................................................. 11

Translation Limitations .............................................................. 14

Comparative Results ................................................................. 15

Write AutoPIPE Model to Caesar .................................................. 18

Page | 1
CAESAR NEUTRAL FILE VERSIONS

Confirm Version of AutoPIPE (Help> About) and version of CAESAR file


that can be imported.

Page | 2
TRANSFERING CAESAR MODEL TO AUTOPIPE

Generating Caesar cii file in Caesar v5.0

Open Caesar and go to the Tools menu

Page | 3
Convert Caesar *.C2 (v5) or
*._a (pre v5) Caesar file to
ii

Click Browse button to


open dialog below to
select the Caesar input
file (*.C2 or *._a)

Page | 4
Note: The following error may occur when a CAESAR *.CII file is opened in AutoPIPE:

forrtrl: severe (64) - Input conversion error

Older builds of CAESAR 5.3 have an issue with $CONTROL section - where location of
a variable was incorrect. This is a known issue - that is also mentioned in release notes of
CAESAR. Install latest SP2 of CAESAR 5.3 before exporting CII file.

Page | 5
In AutoPIPE

V8i v.9.4 and higher: File > Import> Caesar (*.cii), Select the cii file

V8i v.9.3 and lower: File > Open > Caesar (*.cii), Select the cii file

AutoPIPE V9.2 or later

Select the AutoPIPE input working units

Page | 6
AutoPIPE Pre-V9.0

The matching Caesar Units file must be selected

Autopipe Units can be any


from drop down list.
Caesar units file is *.c2u
which must match the units
at the bottom of the cii file

Caesar units file is


SIMM.c2u matches
the units at the
bottom of the cii file

Page | 7
The model opens in AutoPIPE

Page | 8
TRANSFER LARGE CAESAR MODELS

Page | 9
AutoPIPE

Page | 10
AUTOPIPE CONFIGURABLE MAPPING

CIIMAP File in AutoPIPE program folder

Piping Code
Material
Supports
Force Moments, Displacements, Uniform Loads and Cut Short
Tees
Hanger Design Code
Convert Caesar RIGID Elements
RIGID Stiffness
Default Flange length
Caesar Node Names
Writing Y support
Default EXEC Options

Part copy of CIIMAP file below:


////////////////////////////////////////////////////////////////////////

/// Mapping of components between Caesar II and AutoPIPE.

///

/// Note that this file is not free format. Format of each section

/// is fixed (rows and columns). Items outside these sections are

/// not read.

////////////////////////////////////////////////////////////////////////

/// Import (CII -> AP)

/// Piping code mapping. Leave unsupported codes as blank. Maximum 30

/// Piping code is selected based on the first allowable auxilary data

///

/// Col 1: CII piping code number

/// Col 2: AutoPIPE piping code designator

/// Col 3: AutoPIPE piping code number (IRCODE)

/// (2x,i5,1x,a5,1x,i5)

////////////////////////////////////////////////////////////////////////

Page | 11
#$ IMPCODE

1 B31.1 1

2 // not used

3 B31.3 3

4 B31.4 4

5 // B31.5 - not available in AutoPIPE

6 // not used

7 // not used

8 B31.8 8

9 O31.8 // B31.8 Offshore

10 // not used

////////////////////////////////////////////////////////////////////////

/// Import (CII -> AP)

/// Load case mapping (20 cases). Displacement, Forces and Moments

/// and uniform loads defined in auxiallary screens are applied to

/// load cases defined below.

///

/// Col 1: Load case

/// (2x,3(a3,1x))

////////////////////////////////////////////////////////////////////////

#$ IMPLDCASE

U1 U2 U3 U4 U5 U6 U7 U8 U9 // Forces and Moments

T1 T2 T3 T4 T5 T6 T7 T8 T9 // Displacement

U1 U2 U3 // Uniform loads

GR // Cut short - single load case

Page | 12
Note: Typically in Caesar up to 9 displacements are combined with thermal
loadings in the Caesar analysis module. Hence these are defined T1 to T9 in the
CIIMAP file. But these can be changed to any AutoPIPE load case e.g. first 6 cases
maybe thermal and last 3 cases may be seismic E1 to E3 as below.

All displacements are imported as XTRA data > imposed displacements and not as
thermal anchor movements
////////////////////////////////////////////////////////////////////////

#$ IMPLDCASE

U1 U2 U3 U4 U5 U6 U7 U8 U9 // Forces and Moments

T1 T2 T3 T4 T5 T6 T7 T8 T9 // Displacement

U1 U2 U3 // Uniform loads

GR // Cut short - single load case

////////////////////////////////////////////////////////////////////////

#$ IMPLDCASE

U1 U2 U3 U4 U5 U6 U7 U8 U9 // Forces and Moments

T1 T2 T3 T4 T5 T6 E1 E2 E3 // Displacement

U1 U2 U3 // Uniform loads

GR // Cut short - single load case

Page | 13
TRANSLATION LIMITATIONS

Caesar neutral file format (*.cii) does not support the following:

Load combinations
Beams
Hydrodynamic data
Point Static Earthquake Factor
User Nozzle Flexibility
User Weld Efficiency
Flanges not supported in Caesar mapped to RIGID Options or
Valve
Soil Spring data
Wind loading data
Only 9 displacements in Caesar
Only 3 seismic cases (UDL g) in Caesar

Page | 14
COMPARATIVE RESULTS

Sample Model has comparative Non-Linear Thermal Results within 6%.


AutoPIPE has more advanced non-linear analysis engine with load
sequencing and expect more accurate non-linear results than Caesar.

Input Data

Piping Code = B31.3 : 2006

Pipe OD = 1370.0000 Allow Stress = 150 N/mm2


Wall Thickness = 10.000 Bend Radius = 1370 (bend 70 = 2055), close
miters
Material : Carbon Steel Support friction = 0.3
Temp = 200C, Press = 0.25 N/mm2 2 Valves at nodes 252, 263

Caesar

Page | 15
AutoPIPE

Thermal Displacement Results

Page | 16
Page | 17
WRITE AUTOPIPE MODEL TO CAESAR

Geometry, Pipe Sizes, Supports, Materials, Tees, SIFs, Nozzles, RIGIDS,


Valves, Flanges,Reducers, Expansion Joints, Support Tags, Pressure/
Temperatures, Seismic, displacements, Force/moments, Cut Short etc

AutoPIPE V8i 9.2 and lower AutoPIPE V8i 9.3 and Higher

File> Save As> CAESAR (*.cii) File> Export> CAESAR (*.cii)

Page | 18
Tools > External Interfaces > Caesar II Neutral File

Convert Neutral file to Caesar Input file

Page | 19
Page | 20
Page | 21
Caesar Tee / Hanger Data

AutoPIPE Tee / Hanger Data

Page | 22