You are on page 1of 1

CLIMPIPE SECTION ALU2

Pipework Insulation

Description Presentation
ISOVER glass wool tube, cylindrical and with a longitudinal Thickness d, mm. Complies with RITE

Saint Gobain Isover Ibrica, S.L. reserves the right to modify, totally or partially and without prior notification, the information contained herein. Likewise, the absence of unintentional errors cannot be guaranteed. 06/04/16
slit, covered on the outside face with glass mesh reinforced
40-60 30, 40
aluminium foil which acts as a vapour barrier. 40, 50
Tmx. C 60-100 30, 40 40
Applications
100-180 40 50* 50
Because of its high thermal properties and excellent fire-
Interior Dint mm 42 68 60 76 89 114 140 169 219
safety behaviour, CLIMPIPE SECTION ALU2 is the ideal solution diameter Dint pulgadas 1 1/4 1 1/2 2 2 1/2 3 4 5 6 8
for insulating:
Length l, mm 1,2
I ndoor pipe networks in thermal installations and
equipment, both for residential and industrial buildings. Box dimensions, m 1.20x0.60x0.485 1.20x0.60x0.600
Boxes/Pallet 10 8
Technical Properties
Pallets/Truck load 22
Symbol Parameter Icon Units Value Standard Also available in diameters of 21, 27, 34 mm, (1/2, 3/4, 1 inch), 25 mm thick.
*Available in 50 mm upon request.
0.038 (50)
Thermal conductivity 0.055 (150) Ventajas
lD declared as a function W/mK (C) EN-ISO 8497
of temperature* 0.066 (200) Easy to place on the pipe thanks to its longitudinal slit.
0.101 (300) Incorporates a self-adhesive tongue to ensure easy closing.
EN 13501-1
Reaction to fire Euroclass A2L-s1, d0
EN 15715 Prevents pipe condensation.
Inert material, inhospitable for micro-organisms.
Maximum operating
ST
temperature
C 180** EN 14707 Sustainable product. 100% recyclable. Recycled material
> 50%
Mineral wool: water-
MU vapour diffusion - 1 EN 12086 Non-corrosive to metals, in accordance with ASTM C-795 y
resistance, m C-781 standards. See Karnes curve:
Facing: water-vapour
Z m2hPa/mg 130 EN 12086 Note: the chemical analyses
diffusion resistance Karnes curve
ppm of ions conducted in
The vapour diffusion- accordance with ASTM
MV equivalent air layer m 100 EN 12086 Corrosive Zone standards C-795 and C-871
thickness, Sd show that ISOVER stone
wool products do not cause
*Estimated thermal conductivity at 10C of 0.032 W/mK. corrosion to the steel, as the
** The temperature of the covering must not exceed 80 C. Cl- + F- (1) relationship between the F
+ Cl and the Na+ + SiO3 ions
is in the lower part of the
Karnes Curve.
Thickness Interior diameter,
Designation code Non corrosive zone
d, mm dI , mm
(1)
position of the ISOVER
EN 13467 EN 14303 Na + SiO3 ppm mineral wools.
21-140 MW-EN 14303-T8-ST(180)-MV1 (1): posicin de las lanas minerales de Isover Espaa.
25-120
150-273 MW-EN 14303-T9-ST(180)-MV1

Certificates
CCaalliiddaadd aaiirree C alida d aire
rr r
e l'air intrieu

int
e l'air intrieu

int

erio
erio

r Q uali t
r Q uali t

d
d

y
y

IInntt Int lit


eerriioo lliitt erio
r Qua
Quuaa
rr Q

C alida d aire
C alirda d aire

Installation Guide
r
e l'air intrieu

int
e l'air intrieu

erio
int
erio

r Q uali t
r Q uali t

Additional information
d

Int lit
d

erio
Inr Qua
y

ter it
ior Qual

available at: www.isover.es


www.isover.es @ISOVERes
+34 901 33 22 11 ISOVERaislamiento
isover.es@saint-gobain.com ISOVERaislamiento
www.isover-aislamiento-tecnico.es isoveres

Construimos tu Futuro