Project Specifications
Characteristics of the mixture
Maximum size aggregate
Characteristics of the cement, water
aggregates and admixtures
Characteristics of the plastic and/or hardened
concrete
Temperature, slump, air content
Compressive and/or flexural strength
DOWNLOADED FROM http://annacivil.tk/
Strength specimens
ASTM C 31 field molded specimens
ASTM C 192 laboratory specimens
6 x 12 for 1 inch or greater max size CA
4 x 8 for -inch or less
Beams are 6 x 6 x 30-inches
Field specimens cured in same manner as
structure
Lab specimens cured in sat. limewater or
moist room.
DOWNLOADED FROM http://annacivil.tk/
Destructive Testing of
Hardened Concrete
ASTM C 39 for test cylinders
Strength effected by L/D ratio
Condition of the ends of samples
Sulfur mortar caps vs unbonded neoprene caps
Loading rate (20-50 psi/sec)
DOWNLOADED FROM http://annacivil.tk/
R = PL/bd2
DOWNLOADED FROM http://annacivil.tk/
L = span
R = 3PL/2bd2
DOWNLOADED FROM http://annacivil.tk/
Ts = 2P/ld
DOWNLOADED FROM http://annacivil.tk/
NDT
Compressive Strength
Rebound - Schmidt Hammer
Penetration Testing - Windsor Probe
Maturity Testing
In-Place Compressive Strength
DOWNLOADED FROM http://annacivil.tk/
Frequency of Testing
FA Aggregate Moisture testing
Twice daily
1% change effects mix water requirement by 13
pcy
Slump Test
First batch of concrete delivered each day
When consistency appears to vary
Strength cylinders are made
Temperature of concrete recorded
DOWNLOADED FROM http://annacivil.tk/
Cont
Air content tests
Initial batch of concrete
When concrete test cylinders are made
Temperature of concrete recorded
DOWNLOADED FROM http://annacivil.tk/
Cont
Concrete strength testing for each class of
concrete placed
Not less than once per day
Not less than once for each 150 cy of concrete
placed
Not less than once for each 5000 sq ft. of surface
area for slabs and walls.
One 7-day, two 28-day cylinders are required
for each test and one or more hold
specimens.
DOWNLOADED FROM http://annacivil.tk/
Moisture Content of
Aggregates
Oven dry method
Microwave
Moisture meter
Electrical resistivity
DOWNLOADED FROM http://annacivil.tk/
Plastic Concrete
Sampling freshly mixed concrete
ASTM C 172
2 or more portions within 15 minutes
Consistency
Slump test ASTM C 143
Test to be completed in 2 minutes after obtaining
sample
Vebe consistometer
DOWNLOADED FROM http://annacivil.tk/
Cont
Temperature measurement
ASTM C 1064
This test should be completed within 5 minutes
after obtaining the sample
Air content
ASTM C 231 pressure method
ASTM C 173 volumetric method
Test to be started within 5 minutes after obtaining
sample
DOWNLOADED FROM http://annacivil.tk/
Time of setting
ASTM C 403
Penetration resistance as a function of time
Initial set 500 psi (2-6 hours)
Final set 4000 psi (4-12 hours)
DOWNLOADED FROM http://annacivil.tk/
Durability
Frost Resistance
ASTM C666
Freezing in air and thawing in water
Sulfate Resistance
ASTM C1012
Corrosion Resistance
ASTM C876 - Potentiometric Mapping
DOWNLOADED FROM http://annacivil.tk/
Corrosion Determination -
Potentiometric Mapping
DOWNLOADED FROM http://annacivil.tk/
Probability of Corrosion
Less than -0.20V 90% No Corrosion
Greater than -0.35V 90% Corrosion
Between -0.20V and -0.35V increasing
probability of Corrosion
DOWNLOADED FROM http://annacivil.tk/
DOWNLOADED FROM http://annacivil.tk/
Other Tests
Determination of Chloride Ion Content
in Hardened Concrete
ASTM C1152
ASTM C1218
Corrosion threshold level
DOWNLOADED FROM http://annacivil.tk/
Infrared Thermography
Technique used for locating shallow delaminations,
cracks, and voids.
Infrared Thermography is based on two basic
principles from heat transfer: conduction and
radiation. Sound materials with no voids, gaps, or
cracks are more thermally conductive than materials
that are delaminated or contain moisture.
This allows rapid areal mapping of internal
conditions. It should be noted that the IT method is
most useful for the detection of shallow defects and
flaws.
Tests For: Voids, Delaminations, Cracks, Moisture.
DOWNLOADED FROM http://annacivil.tk/
DOWNLOADED FROM http://annacivil.tk/
DOWNLOADED FROM http://annacivil.tk/
DOWNLOADED FROM http://annacivil.tk/
This is a photo of a
condominium. The dark (cool)
streak is water in the wall under
vinyl siding from a leaking
washing machine on the third
floor.
The camera showed the source
DOWNLOADED FROM http://annacivil.tk/
DOWNLOADED FROM http://annacivil.tk/
NDT
Ultrasonic Pulse Velocity
Dynamic modulus of elasticity
Cracking
DOWNLOADED FROM http://annacivil.tk/
NDT
Other Dynamic Tests
Impact echo
DOWNLOADED FROM http://annacivil.tk/
8
Width (ft)
6
1.2
1.0
0.95
4 0.85
0.8
0.5
0.0
0
-7 -4 -1 2 5 8
Length (ft)
Living Room Area
Graphical IES Test Results (Normalized Thickness) from the Balcony Deck