You are on page 1of 34

FIRE & GAS DETECTION

Conventional systems Test equipment Pages 302-305


Panels
Standard and extinguishant Page 261 Pages 305-308
Aspirating systems
Repeaters
Standard, extinguishant
& I/O boards Pages 262-263 Environmental detection Page 309
Panel accessories Pages 263-265
Detectors and bases Pages 266-269 Intrinsically safe Pages 309-314
Manual call points & acc. Pages 269-272
Sounder, Strobes & bells Pages 273-274 Door retainers Pages 314-315
Duct detector & acc. Page 276
Beam detector & acc. Page 276 Power Supply Units EN54 Pages 315-316

Previous Section Addressable systems PSU & batteries Page 316


Panels
Standard and extinguishant & acc. Pages 276-278
Gas detection parking Page 317
Repeaters Page 278
Networking card Page 279
Communication Page 317
Panel accessories Pages 279-280
Zone expansion card Page 281
Accessories transformer Page 281
Module & Interface Page 281
Environmental detection Page 282
System accessories Page 282
Fire alarm cable & acc. Page 284
Addressable accessories Page 285
Detectors, bases & acc. Pages 287-292
Duct detector Page 292
Beam detector & acc. Page 292
Flame detector Pages 293-294
Detector programmer Page 294
Manual call points & acc. Pages 294-297
Strobes & sounders Pages 297-300
Accessories, I/Os etc. Pages 300-301
Protective covers & acc. Page 302

253
RETAILFire Protection & Safety Fire Protection & Safety

EDUCATION
Is your Retail Space Do You Have the Right
Fire Protected, or In Protection for your
Need of an Upgrade? Educational Facility?

Get The Hands-On Service You Deserve! Get The Hands-On Service You Deserve!

Fire Protection & Life Safety Whats Important Whats Important Determine the Educational High Schools & Colleges Other Issues to Consider
solutions should be installed Protect your investment F ire protection will be aligned with the base Facility Size These facilities offer more complex Different types of spaces classrooms,
in all types & sizes of retail Education & training of employees of the building, & then the spaces occupied and physically larger challenges as auditoriums, gymnasiums, living areas
environments. is a must by tenants Pre-School or Day Care Facilities they can be a campus environment Code requirements in place when the
Carry out your corporate mission Changes need to be closely monitored Operators & employees must realise with more area, more occupants, structure was built
Whether you have a large retail Systems must be simple and flexible language barriers and different
operation, medium sized or small that the occupants will not be able to Local Governmental requirements
Are You a Medium Retail assist in their own self-preservation. cultures represented.
establishment, fire protection & life Size of the structure
safety should be priority number one. Operation? Find out what kind of Fire protection features are based on the Concerned with early detection of
developing emergency conditions
Fire alarms & protective signaling systems (Shopping Centre or Specialty Store) protection you need from size of the facility
Requirements are Based on
Real-time mass notification of the
Smoke detection systems There May Be Some a Certified Fire Professional In some cases, there may be no, or limited,
occupants is essential BOTH Fire Codes and Policies
code-required protection
Life safety systems Challenges for Fire Protection Fire Systems can include: Some facilities may be a converted, Students know their surroundings and can Set by the Owners
Sprinkler systems and Life Safety or occupied residence
assist in their own self-preservation
- Addressable & conventional fire systems Protection requirements have to be made
...AND More!
High Tenant Turnover Can Create - IP communications on a building-by-building basis
Additional Challenges - Heat & flame detectors Primary Schools Get Started Changes & alterations need to be
Are You a Large Retail - CO & gas detectors What tools are needed to detect a closely monitored
Operation? Fire Protection Are fire alarm & other systems still - Fire communicators Some students may be able to assist problem, keeping in mind that fire
- Annunciators in their own self-preservation, but Historical value should be considered
& Life Safety Needs May code compliant for next tenant is not the only issue?
- Smoke alarms this cannot be considered when In many settings, consideration has to
Be More Complex Do space changes cause issues with - Smoke detectors designing and installing fire be given to protecting the fire protection What to Consider:
fire protection systems - Manual Call Points protection. However, at this age,
Unique Hazards - Notification devices system from the occupants how can this Is it a single structure or large campus
Is the owner of - Speakers they may be able to understand and best be accomplished?
Large space; may include retail racks follow assignments. Size and construction
- Strobes What is the most effective way to notify
sometimes at heights up to 20 ft. the Shopping - Power & surge protection Variety of occupants:
Simplicity is key all of the occupants?
Significant travel distances to exits & fire Centre mindful - Smoke emitters children and adults
Ability of What is the message or messages that
protection components of these factors; - Relays Do you need
occupants may have to be communicated in an
Variation in commodities what is their - Test equipment emergency? mass notification
- Protective covers be inconsistent
capabilities
knowledge - Voice evacuation What is the best way to notify
of code - Mass notification emergency responders?
requirements - Sprinkler systems
- Emergency lights

Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za

254 255
Fire Protection & Safety
COMMERCIAL Fire Protection & Safety

INDUSTRIAL
Do You Have the Do You Have the Right
Right Protection Protection for your
for your Building? Industrial Facility?

Get The Hands-On Service You Deserve! Get The Hands-On Service You Deserve!

Fire Protection Trends & buildings converted to open, shared Simplicity is Key Highly Protected Risk Facilities and strobes, will meet the notification C omplex evacuation including
Issues for Large Commercial retail spaces requirements employees in large buildings with
Research & technology use such as the Fire protection features must match Regardless of its size, if a facility is many obstructions to egress
Where hearing protection is required,
Occupancies pharmaceutical industry the characteristics of the larger considered a highly protected risk, additional visible notification is needed Safe, orderly shutdown of operations
commercial spaces. Because of the more fire protection features may be so that any unattended processes do
The practice of reducing fire risk varying nature of the occupancies, A well thought out design considers
in large commercial facilities for Structure & Tenant required: all aspects of signal transmission and not contribute to the problem
and the fact that many locations will Early detection & response to
decades has proven to reduce Considerations have constant changes in tenancy, P roperly designed sprinkler protection occupant notification
the number of deaths, injuries & for the occupancy and hazards within In larger facilities, various levels of mass hazardous materials released into
One of the biggest challenges of keeping fire protection as simple as the environment accidentally or
property loss from fires. Today, the the structure notification may be needed rather than
use of fire protective systems is much commercial occupancies, such as possible is key. intentionally
Built-in passive fire protection one universal signal to evacuate
greater in high-rise office buildings industrial parks, is that the type of features, such as fire-rated barriers and
than in smaller structures. This prospective tenants is usually not Risk Analysis penetration seals Mass notification systems for manu Health and Safety at Work Act
prevalence of robust fire protection known at the time of construction. facturing & industrial facilities will and Other Requirements
Designers experienced in mass Adequate fire alarm and security services
is credited with the lower rate of When the building has no specific often rely on immediate & intrusive
tenant in mind, several questions notification should analyse the risks Concerned management that provides components, such as: The Health & Safety at Work act
fire deaths & property damage in in large commercial facilities,taking adequate protection
high-rises than in smaller structures. need to be considered: Sirens, horns, etc. 1974 and similar organisations
into account the wide variation in including fixed require plans to keep the
W hat types of occupancies does the the characteristics of commercial emergency plans Indoor/outdoor loudspeakers
Large commercial spaces can owner allow?
workplace safe. Employees must
house a variety of operations occupancies. An objective risk No external exposures Voice evacuation system be protected in the following
Are automatic sprinklers needed? analysis must include: that can cause a loss in operations or circumstances:
& occupancies: If so, what design? the insured structure
Increased visible signaling, such
Size of the structure as electronic signage throughout Welding & other hot work operations
High rise office & residential buildings Will a protective signaling system Adequate and trained
Locations for areas of refuge the building
Large multi-screen movie theaters be required? emergency services response from Hazardous material spills & cleanups
What will need to be included in the Protection of circuits and pathways that in-facility teams, public or private Fire fighting & similar operations as
Warehouses for non-public storage transmit signals emergency response organisations Scenarios to Plan For
uses such as consumable goods design? part of employees normal function
What will be universal enough to fit Message content In an industrial facility, an emergency Safe handling of materials such
Leasable spaces for non-specified
occupancies any anticipated occupancy? Message Protective Signaling Systems plan should be tailored to the as radioactive waste
intelligibility threats that can impair operations
Data centers Is the buildings structure suitable Building occupants & emergency
responders must be notified of including:
Business parks for commerce that will take place
with shared in the space? an emergency, and this may be F ire & associated perils such as
spaces accomplished using a protective explosions
For example, a paper manufacturing signaling system. Terrorist threats in particular to
Repurposed or storage operation cant be located in
industrial sites, a wooden structure In many locations, a system of audible nuclear power facilities
such as old mill & visible devices, such as horns, bells Severe weather

Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za

256 257
Fire Protection & Safety
HOSPITALITY

Do You Have the Right


Protection for your
Hotel, Restaurant,
Nightclub or Theater?

Get The Hands-On Service You Deserve!

Fire Protection Trends & Issues Size of the Facility Must W


 ill occupants not specifically
involved with the emergency
for Hospitality Occupancies Be Considered! be notified?
With life safety of large crowds in Small Facilities
mind, its important to consider the O ccupants are closer to exits and What can be Expected
purpose of hospitality facilities in communications of Emergency Responders?
fire protection design:
Evacuation procedures are simpler In any of these cases, emergency
Restaurants and lounges Less fire protection may be required responders are important in making
Private and country clubs some of these decisions:
Fire systems are easier to operate
Ballroom and banquet facilities and manage W hat is their standard emergency
Hotels procedure?
Theaters Large Facilities What is the expected response to an
Arenas and stadiums emergency?
Special needs due to:
Nightclubs and concert venues Will there be any special requirements

Delivered!
F ood service areas with hood of the responders?
suppression system requirements What, if anything, would enhance
Most hospitality locations are Larger administrative and
all considered assembly spaces. their ability to communicate in a large
management spaces building?
Code requirements are determined Transient residential spaces such
by facility size, number of occupants, In addition, has the jurisdiction
as sleeping rooms developed any special requirements
and the buildings construction,
design and materials. Mechanical spaces with operational for these locations?
equipment ADI is committed to a delivery service that is fast, reliable and accurate. We aim to
Other important matters of fire protection:
Potential loss of property and income
For these larger buildings, some
questions must be considered: respond to our customers needs as quickly and efficiently as possible.
Facility security and its integration with W ill occupants evacuate totally to safe
fire protection systems
Staff training for those responsible for
harbor outside or inside the building?
How will these areas be arranged and
Smart security connections. Delivered. Because we care.
fire systems protected?

Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za

258
FIRE & GAS DETECTION Conventional Systems : Panel

FIRE & GAS DETECTION


Manufacturers Code K11020 M2 SIGMA CP EN54 2 Zone conventional fire panel F0626

2 zone, 4 Wire panel


Standby current: 0.065 Amps
Alarm current: 0.1 Amps
Fully programmable using simple menu options
Simple, single board construction
Installer friendly
Compatible with wide range of detection devices
Two monitored sounder outputs
1 year warranty

Manufacturers Code K11040 M2 Sigma 4 Zone conventional fire panel F0486

Sigma CP - 4 Wire conventional fire control panels


Fully programmable using simple menu options
Simple single board construction
Installer friendly
Compatible with a wide range of detection devices
Two monitored sounder outputs
3 Amp power supply
Auxiliary power output
1 year warranty

Manufacturers Code K11080 M2 SIGMA CP EN54 8 Zone conventional fire panel F0625

New products
8 zone, 4 Wire panel
Standby current: 0.093 Amps
Alarm current: 0.55 Amps

always in stock
Fully programmable using simple menu options
Simple, single board construction
Installer friendly
Compatible with wide range of detection devices
Two monitored sounder outputs
ADI continually expands its portfolio with 1 year warranty

the latest products and technologies. K11031 M2


Order
Manufacturers Code Sigma XT - Extinguishant control panel. 3 Zones with release MCP F0488

www.adiglobal.com/za Three detection zones as standard

0860 22 55 23 or +27(0) 11 574 2500 NOW! Any single zone or any combinations of zones can be configured to release
Configurable first stage sounder delays
Configurable detection delays
Zero time delay upon manual release option
Compatible with I.S. barriers
Countdown timer shows time remaining until release
Built in extract fan control
1 year warranty

ADI Professional Training Manufacturers Code K11031 F2 Sigma XT - Conventional extinguishant control panel. Flush mount

Sigma XT 3 Zone flush mount single area extinguishant control panels


F0795

Battery capacity: Up to 2 x 7Ah


Certification: BS EN12094-1, BS EN54-2: BS EN54-4
ADI has a wide range of training courses Enclosure details (mm): Flush 415W x 315H x 86D
1 year warranty
on new products and technologies.
Increase your knowledge, uncover new
opportunities and keep up to date with
Manufacturers Code K21042 M3 Conventional extinguishant fire panel Sigma XT+ 4 Zone 2 area F0791
the very latest technology!
Sigma XT+ 4 Zone multi-area extinguishant control panels
2 Area
Battery capacity: Up to 2 x 7Ah
For more information on our training courses, email us on training.za@adiglobal.com Certification: BS EN12094-1, BS EN54-2: BS EN54-4
more products more locations more savings more support Enclosure details (mm): Surface 385W x 520H x 110D
1 year warranty

260 Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za 261
FIRE & GAS DETECTION Conventional Systems : Repeater Conventional Systems : Repeater

FIRE & GAS DETECTION


Manufacturers Code K01080 M2 SIGMA CP-R 8 zone repeater panel for Sigma conventional range 230 Vac input F0766 Manufacturers Code W911110 W8 Extinguishant panel status ind. 6 lamps, mode select, manual release IP65 F0616

Sigma CP-R Fire control panel repeaters 6 Lamps weatherproof (IP65) extinguishant status unit
Battery capacity: Up to 2 x 7Ah With mode select & manual release function
PSU 230V version Enclosure details (mm): Surface 256W x 170H x 60D
8 zones 1 year warranty
Enclosure details (mm): Surface 385W x 310H x 90D
1 year warranty

Conventional Systems : Accessories


Manufacturers Code W911113 W8 Sigma SI 10 Lamps. Mode select and manual release. IP65 weather resistant. F0490
Manufacturers Code K580 SIGMA CP ancillary PCB F0691
10 Lamps weatherproof (IP65) extinguishant status unit
Provides a means to extend fire, fault, coincidence and zonal alarm volt free contacts to With mode select & manual release function
locations remote from the control panel via a 2 core data bus Enclosure details (mm): Surface 256W x 170H x 60D
Compatible with all Sigma CP control panels Not suitable for use with Sigma XT+ control panels
Available in enclosures that match the styling of the control panel 1 year warranty
Requires a nominal 24V DC power supply to operate
1 year warranty

Conventional Systems : I/O Board


Manufacturers Code K588 SIGMA XT ancillary board F0485
Conventional Systems : Accessories
Two wire serial connection
Up to 7 per system
230V AC or 24V DC powered versions
Manufacturers Code K16000 L2 Fire document box. Slim design to match Syncro and Sigma panels F0765
Volt free relay outputs for fire and extinguishing system status
Relay operated LED indicators Document enclosure
1 year warranty Matches design & colour scheme for Sigma CP/XT & Syncro AS panel ranges
Standard version
Enclosure details (mm): Surface 385W x 310H x 60D
Conventional Systems : Repeater 1 year warranty

Manufacturers Code K911010M8 Extinguishant panel status indicator with 6 lamps and manual release F0613

6 Lamps extinguishant status unit


Manufacturers Code A4-DOC-BOX-R-FIRE FIRE document box. Red with fire logo F0814
With manual release function
Enclosure details (mm): Surface 186W x 132H x 50D Ideal for the safe keeping of important documents, log books and other paperwork for a
1 year warranty buildings fire system
Specifically branded for fire applications
The enclosure is low profile 50mm
Lockable and is provided with 2 keys
Manufacturers Code K911100 M8 Extinguishant panel status indicator with 6 lamps and mode select F0615 1.2mm Powder coated steel
Physical size - 300mm x 235mm x 50mm
6 Lamps extinguishant status unit 1 year warranty
With mode select function
Enclosure details (mm): Surface 186W x 132H x 50D
1 year warranty
Manufacturers Code 430SS Fits SYNCRO AS and SIGMA panels F0694

Stainless steel weatherproof enclosure for fire panel


Powder coated
Manufacturers Code K911110 M8 Sigma SI 6 Lamps with mode select and manual release F0489 See through window to view fire panel information
IP66
6 Lamps extinguishant status unit
1 year warranty
With mode select & manual release function
Enclosure details (mm): Surface 186W x 132H x 50D
1 year warranty

262 Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za 263
FIRE & GAS DETECTION Conventional Systems : Accessories Conventional Systems : Accessories

FIRE & GAS DETECTION


Manufacturers Code K27101 Illuminated warning sign with internal sounder F0745 Manufacturers Code STI-6400 Exit Stopper for fire doors with 105dB battery driven sounder F0761

Illuminated signs using high intensity LED indicators Exit Stopper Multifunction door alarm - red
Enclosure: 1.2mm mild sheet steel Helps prevent unauthorised exits/entries
Finish/colour: Lid & box - EPC (BS 00 A 05, mid grey fine texture) 95/105 dB alarm when activated
Text Colour: Red on black Set to sound for 30 seconds, 3 minutes or continuous
Wording: FIRE ALARM EVACUATE AREA (Bespoke messages) Can be used as an annunciator
Enclosure details (mm): Surface 300W x 195H x 50D Three year guarantee against breakage of polycarbonate in normal use (one year on electro
1 year warranty mechanical and electronic components)
136mm x 136mm x 50mm

Manufacturers Code 470-12 Water sensor (1 probe incl) 12Vdc F0719

Can monitor up to 2 sensing probes (470PB) simultaneously


Selectable (Hi or Low) sensitivity setting
Includes one 470PB external water probe
Includes Form C output relay
1 Year warranty

Manufacturers Code TS300 TS300 Hardwired temperature monitor

Allows simultaneous use of local and remote temperature probes, programmable


hysteresis and audible alarm with silence timeout 220/24V B1858 2670 F0726 2609 F0732
Illustrate the sensors flexibility in installation, programming and operation 24VDC Relay coil. 10Amp contacts VON DUPRIN Emergency exit alarm lock Von Duprin double door strike
1 Year warranty 24v DC version Secure, alarmed code-compliant Von Duprin 2609 double door strike -
Current drain - 48mA energised protection for secondary exits Black for use with Von Duprin emergency
Normally open & normally closed relay Ideal for deterring theft in restaurants and exit alarm
contacts 10A @220VAC retail establishments
Reverse polarity protection Designed to operate in a variety of
Back emf protection environments
Manufacturers Code ELM-FUSE-KIT Engineer Fuse Kit F0801 Physical size - 37mm x 29m Armed and disarmed by key, using a
standard rim cylinder
ELM-FUSE-KIT (5 of each value)
Door width range 914mm to 1219mm
20mm (Fast Blow)
Works off 9V battery or mains using a
F500mA, F1A, F1.6A, F2A, F2.5A, F3.15A ,F4A, F5A, F6.3A, F10A
transformer
20mm (Time Delay) T1A, T2A, T3.15A, T5A
1 year warranty
32mm (Fast Blow) F1A, F2A, F5A, F10A

Manufacturers Code ELM-RES-KIT Resistor kit 30 x 9 Common types (270 in total) ELM-RES-KIT Elmdene F0810

Housed in neat compartment plastic boxes they are labelled clearly for quick
identification of components.
ELM-RES-KIT (30 of each value) 470R, 680R, 1K, 2K2, 3K9, 4K7, 6K8, 10K, 20K

Manufacturers Code K91000 M10 Extinguishing equipment hold off unit. Green D50-240HW DTK-CMHWMOUNTSM DTK-2MHLP24BWB
Sigma Si Extinguishant hold off switch unit 240 Vac, 50kA, SPD Small mounting plate for HW/CM series 24V, 2 Pair, hybrid field replaceable
Green button (Red also available) 240 VAC, 50kA, Surge Protection Device Small mounting plate for HW/CM series suppression module w/hardwired base
Grey lid & box (BS00A05) Type 1 UL1449 3rd edition listed 1 year warranty 24V, 2 Pair, hybrid field replaceable
Enclosure details (mm): Surface 97W x 97H x 50D 1 year warranty suppression module w/ hardwired base
1 year warranty 1 year warranty

264 Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za 265
FIRE & GAS DETECTION Conventional Detectors : Optical Smoke Conventional Detectors : Optical Smoke

FIRE & GAS DETECTION


Manufacturers Code 55000-317APO S65 Conventional photoelectric/Optical smoke detector F0570

Wide operating voltage, 9-33 VDC


Advanced electronic technology
Flashing LED option
Magnetic test switch option
Can be used on security systems
Electrically compatible with Series 60
ORB-OP-12003-APO F0663 ORB-OP-53027-APO F0768 Mechanically compatible with Series 60
ORBIS optical detector with flashing LED ORBIS intrinsically safe optical detector with flashing LED Proven detection performance
Responds well to slow-burning, smouldering fires Reduces false alarms 3 year warranty
Good performance in both black and white smoke Recommended for early warning of fire in most areas
Transient rejection algorithms reduce false alarms Improved sensitivity to black smoke
Automatic drift compensation with DirtAlert, a yellow flashing
LED, to easily identify dirty detectors
Compensation for slow changes in sensitivity
Algorithms for reliability of alarm
Conventional Detectors : Ionisation Smoke
Red flashing LED at StartUp confirms that the device is operating.
3 year warranty
SensAlert, yellow flashing LED, indicates faulty operation
FasTest takes just 4 seconds to test and confirm detectors are Manufacturers Code 55000-216APO Conventional fire system ionisation detector Apollo S65 range F0773
functioning correctly
DustDefy system prevents dust ingress while maintaining airflow Series 65 Ionisation smoke detector
3 year warranty Responds well to fast-burning, flaming fires
Designed to operate in a variety of environments
Flashing LED and magnet operated test switch option

Conventional Detectors : Heat 3 year warranty

Conventional Detectors : Heat


ORB-HT-11017-APO F0668 ORB-HT-51146-APO F0769 Manufacturers Code 55000-122APO S65 Conventional heat rate of rise A1R (57C) F0571
ORBIS heat detector. Rate-of-rise, MAT 80C CR - with flashing LED ORBIS intrinsically safe heat detector. Rate of rise
Can be used for applications where smoke detectors are unsuitable
Can be used for applications where smoke detectors are unsuitable Orbis IS A1R Heat Detector with flashing LED
Ideal for environments that are dirty or smoky under natural conditions
Ideal in environments that are dirty or smoky under normal conditions Can be used for applications where smoke detectors are
Red flashing LED at StartUp confirms that the device is operating. unsuitable Wide operating voltage
SensAlert, yellow flashing LED, indicates faulty operation Ideal for environments that are dirty or smoky under Flashing LED and magnet operated test switch option
FasTest takes just four seconds to test and confirm detectors are normal conditions 3 year warranty
functioning correctly Reduced incidences of false alarms
Single thermistor Increased reliability of detection
3 year warranty 3 year warranty

55000-127APO Series 65 Conventional BR(75C) rate of rise heat detector F0574


Conventional Detectors : Standard Base
Manufacturers Code

Can be used for applications where smoke detectors are unsuitable


Ideal for environments that are dirty or smoky under natural conditions
Wide operating voltage
Flashing LED and magnet operated test switch option
Wide voltage range (9-33 volt DC)
3 year warranty

ORB-DB-00003-APO F0666 ORB-MB-50018-APO F0770


ORBIS detector base complete with diode ORBIS intrinsically safe detector base Manufacturers Code 55000-137APO Conventional heat detector CS 90C static F0628
Grouped terminals to make wiring easy Orbis IS TimeSaver base Can be used for applications where smoke detectors are unsuitable
Two fixing centres Grouped terminals to make wiring easy Ideal for environments that are dirty or smoky under natural conditions
LED alignment mark Two fixing centres Wide operating voltage
Cable stripping guide LED alignment mark Flashing LED and magnet operated test switch option
Detector locking mechanism Detector locking mechanism
Continuity link for voltage testing of zone wiring prior Dual thermistor
3 year warranty 3 year warranty
to commissioning
Other devices continue to work during unauthorised
removal of detectors
3 year warranty

266 Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za 267
FIRE & GAS DETECTION Conventional Detectors : Multicriteria Conventional Systems : Accessories

FIRE & GAS DETECTION


Manufacturers Code M12/40001FULL-00 Firecat 12Vdc smoke & heat detector for use with security systems F0803 Manufacturers Code 45681-508APO Standard relay base 12Vdc for fire and security systems F0624

Voltage 10 - 16Vdc Domestic use ONLY Detector locking mechanism


Current 0.5 - 14mA One way fit
Self monitoring Easy to wire
For interior use only Contains an earth connector
Construction ABS, PC Can be used in fire and security systems
Weight 0.08Kg 3 year warranty
White in colour
Sensing options include: optical, optical-heat, heat rate of rise, static heat
1 year warranty
Manufacturers Code 45681-293 Red cap for all base sounders using S65, XP95 or Discovery F0656

Apollo locking red cap


Dimensions: 110 x 9mm
Conventional Detectors : Standard Base Weight: 20g

Manufacturers Code 45681-200APO Series 65 Conventional common mounting base F0573

Detector locking mechanism


One way fit Manufacturers Code 45681-292 White cap for Apollo base sounders / beacons using S65, XP95 or Discovery
Easy to wire
White locking cap
Contains an earth connector
Dimensions: 100 x 9mm
Contains no electrical parts
Weight: 20g
Terminal for remote indicator
3 year warranty

Manufacturers Code 45681-201APO S65 Detector base complete with diode F0670

Detector locking mechanism Manufacturers Code 53832-070APO S65 Mini disc remote indicator F0576
One way fit
Can be used across the entire Apollo range
Easy to wire
Small and discrete
Contains an earth connector
Anti-tamper screw to protect against unauthorised removal
Continues to work during unauthorised removal of detectors
1 year warranty
3 year warranty

Conventional Detectors : Sounder Base


Conventional Systems : Call Point
Manufacturers Code 45681-512APO Conventional sounder base F0572

32 tones as standard Manufacturers Code 4920016FULL-0018XC Conventional call point with integral 470 and 680 ohm resistors F0538
Provides detection and alarm signal at one point
Diode option available Conventional 470R/680R with LED and back box
High-efficiency, conventional alarm sounder Includes both glass and universal plastic resettable elements
Type A device according to EN54-3, indoor use only Changeover contacts
3 year warranty Potted waterproof option available
Construction: ABS
Weight 0.19Kg
1 year warranty

Conventional Systems : Accessories


Manufacturers Code MCP1A-R470SG-01 Surface mount red call point with 470 Ohm resistor. Glass element F0047

Manufacturers Code 45681-245APO S65 Conventional relay base 24Vdc F0746 Conventional manual call point
Complete with surface back box
Series 65 standard relay base Complete with test key
Detector locking mechanism Supplied with frangible glass element
One way fit EN54-11 standard
Easy to wire Integral 470 Ohm resistor
Contains an earth connector 1 year warranty
3 year warranty

268 Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za 269
FIRE & GAS DETECTION Conventional Call Point : Call Point Conventional Call Point : Call Point

FIRE & GAS DETECTION


Manufacturers Code MCP1A-R470SG-01 Surface mount red call point with 470 ohm resistor. Glass element F0047 Manufacturers Code CXL/GP/R/470R+680R+ Weatherproof conventional surface call point with 470 + 680 + LED IP66 F0639
LED/WP XPRS
Conventional manual call point
Complete with surface back box Weatherproof IP66 Conventional 470R/680R with LED and back box
Complete with test key Includes both glass and universal plastic resettable elements
Supplied with frangible glass element Changeover contacts
EN54-11 standard Potted waterproof option
Integral 470 ohm resistor Construction: ABS
1 year warranty Weight 0.22Kg
1 year warranty

Manufacturers Code MCP4AR000SFK013-11AC Conventional manual call point with N\O & N\C contacts F0792

Unique Plug & Play installation concept


Resettable element (Glass element optional) Conventional Systems : Call Point
Enhanced aesthetics
Backward compatibility
Colour: Red Manufacturers Code WCP1A-Y470SG-K01 Weatherproof yellow call point F0741
Normally open and normally closed contacts
Unique Plug & Play installation concept
1 year warranty
Total Flex-ability in the choice of operating element
Enhanced aesthetics
Backward compatibility
Manufacturers Code MCP3A-G000SF-12 Green manual call point with resettable element indoor A0706 Colour: Yellow
Operating: Glass
Single pole 470ohm resistor & N\O 30Vdc
Resettable 1 year warranty
Dimensions: 93(h) x 89(w) x 59.5(d) mm
1 year warranty
Manufacturers Code WCP3AY000SGK013 Yellow weatherproof conventional manual call point IP67 F0775

N/O & N/C contacts 30VDC, surface mount


-25C to +70C
Glass element that can be changed to a flexible element
Manufacturers Code MCP4A-G000SG-K01 Green manual call point with glass element F0708 Enhanced aesthetics
Fully approved to the latest standards
Unique Plug & Play installation concept Backward compatibility
Total Flex-Ability in the choice of operating element CPD Approved
Anti-tamper facility 1 year warranty
Enhanced aesthetics
Backward compatibility
1 year warranty
Manufacturers Code WCP3A-G000GF-12 Green manual call point with resettable element outdoor IP67 A0707

Weatherproof manual call point


Colour : Green
Manufacturers Code MCP4A-G000SF-K013 Green call point with normally open and normally closed contacts F0740 IP67 Rated
NO/NC contacts (Rated at 30V DC resistive)
Green call point, double pole changeover contacts, surface mount, flexible element, Supplied with resettable flexible plastic element & test key
IP24D, -10 to 55 C 1 year warranty
1 year warranty

Conventional Call Point : Accessories


Manufacturers Code 4990047FULL-0420 Weather proof conventional call point with 470 and 680 ohm resistors. IP66 F0552 Manufacturers Code PS200 KAC Transparent protective hinged cover for manual call point F0562

Conventional IP66 470R/680R with LED and back box Hinged plastic call point cover for fire alarm call points
Includes both universal glass and plastic resettable elements Very easy to install
Changeover contacts
Potted waterproof version
Construction: ABS
Weight 0.22Kg
1 year warranty

270 Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za 271
FIRE & GAS DETECTION Conventional Call Point : Accessories Sounder & Strobe : Sounder/Strobes

FIRE & GAS DETECTION


Manufacturers Code SO/R/SR/15C Red Indoor beacon/base with 15Cd Xenon tube and reverse polarity monitoring F0631

Solex beacon, red lens, red body, shallow base, 15cd


5 lens colour options
Tamper switch option
Construction: Base ABS, FR, PC lens
Weight 0.1Kg
1 year warranty

Manufacturers Code SO/R/DR/15C Red outdoor beacon/base. 15Cd Xenon with reverse polarity monitoring. IP65 F0632
P056 A0520 SCS070 A0740 PS210 A0759
P056 - KAC Hinged cover seal for manual Pack of ten spare test keys for KAC MCP Resettable plastic element for KAC Solex beacon, red lens, red body, deep base, 15cd
call point. Pack of 5 manual call point 5 lens colour options
Tamper switch option
Call point cover anti tamper seals Call point test keys. Packets of 10 PS210 Resettable element Construction: Base ABS, FR, PC lens
For use with the new type KAC call points Flexible element for use on KAC MCP Weight 0.1Kg
and covers 1 year warranty
Pack of 5

Manufacturers Code 531037FULL-0114 Solex Xenon, deep white base with blue lens, 15Cd F0739

Solex Xenon, Deep white base and blue lens, 15Cd


1 year warranty

Sounder & Strobe : Sounder


Manufacturers Code 540501FULL-0389X Sounder shallow base F0512
KG1 X 10 F0045 CXPC F0636 4990078FULL-0437 F0619
Pack of ten spare glass elements Cooper / Fulleon hinged polycarbonate Fulleon manual call point reset- Roshni low profile (RoLP), shallow base, red body
cover table element 102dB(A) sound output
32 tones (user selectable)
Spare EN54 break glass for all KAC call CXPC Pack of 10 in a box polycarbonate Spare resettable element for CX Two stage alarm
points - pack of 10 cover (Box of 10) manual call point (Pack of 10) Automatic synchronisation
Weight: 120g (10 pieces) 1 year warranty Construction: ABS
Dimension: 93mm D x 63mm H
Weight 0.25Kg
1 year warranty

ADI tracks all


competitor promotions
CX-SPAREGLASS F0617 STI-15D20ML F0813 STI/BS F0812 sales.za@adiglobal.com
or call 0860 22 55 23
Spare glass for the Fulleon range of STI Eurostopper multi kit STI/BS Breakable seals
manual call points (10 Pack)
CX Spare glass pack of 10 standard small MCP Protective cover helps prevent Seals for Eurostopper or +27(0) 11 574 2500
arrow malicious or accidental false fire alarms
1 year warranty Comes with red and green inserts
1 year warranty Contact us today to place your order!

272 Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za 273
FIRE & GAS DETECTION Sounder & Strobe : Sounder

SYHO/R F0602 ROLP/SV/R/D XPRS F0778 SY/HO/IP/R F0767


SYMPHONI 120dB Sounder (Tone 6) indoor Markets leading conventional alarm Weatherproof IP66 SYMPHONI High
with 32 tones sounder IP65 output sounder 120dB (A) @ Tone 6
Symphoni high output sounder, red body Roshni low profile (RoLP), deep base, Symphoni high output sounder, red body
High output up to 120dB(A) red body High output up to 120dB(A)
Two stage alarm 102dB(A) sound output @ Tone 3 Two stage alarm
32 tones (user selectable) 32 tones (user selectable) 32 tones (selectable) - 6 tones certified
Weatherproof option Automatic synchronisation for fire use
Construction: ABS, PC lens Construction ABS Weatherproof IP66
Dimension: 108mm D x 96mm H Dimension: 93mm D x 93mm H Construction: ABS, PC
Weight 0.58Kg Weight 0.25Kg Weight: 0.68Kg
1 year warranty 1 year warranty 1 year warranty

AS/SB/24/120/R/R F0763 FL/SV/RL/R/S SWI F0609 FL/SV/RL/R/D/SWI F0618


Sounder / Beacon ASSERTA 120db at Flashni sounder/beacon shallow base up to Flashni sounder/beacon deep base IP65
tone 3, 24Vdc 3 Stage siren IP66 103dB on tone 5 weatherproof. Up to 103dB
Asserta sounder/beacon 24v red 120dB Flashni sounder/beacon, red lens, red Flashni sounder/beacon, red lens, red
red lens body, shallow base, tone select switch body, deep base IP65, tone select switch
Powerful 120dB(A) output at tone 3 High output sounder beacon 101dB High output sounder beacon 101dB
3s stage alarm 18 to 28Vdc Input 18 to 28Vdc Input
42 alarm tones Automatic sounder synchronisation Automatic sounder synchronisation
Construction: ABS, PC With built in Xenon flash With built in Xenon flash
Weight: 1.8Kg Construction: ABS, PC lens Construction: ABS, PC lens
1 year warranty Dimension: 93mm D x 92 mm H Dimension: 93mm D x 92 mm H
Weight 0.33Kg Weight 0.33Kg
1 year warranty 1 year warranty
Fully certified to EN54 parts 2 & 4 Compatible with the new EN54-
the CF3000 is a high specification, 23 certified addressable beacon
intelligent addressable fire control range and offering a network
Sounder & Strobe : Sounder/Strobes panel, which helps protect people, capability from 2 to 126 panels,
property and your reputation for the CF3000 is flexible for a
Manufacturers Code 8500025FULL-0025 Siren/beacon EN54/23 ROLP LX wall, white base, red flash IP65 F0802 business continuity. diverse range of projects.
Roshni low profile (RoLP) LX wall, red flash, red body A comprehensive user interface, To find out more about the
Ultra low current consumption
Up to 7.5m coverage volume (switchable to 2.5m) with a logical menu structure intelligent addressable CF3000,
0.5 or 1Hz flash rate ensures ease of use. visit www.eaton.co.za Tel: 011
Certified to EN 54-23 824 7400
Weight: 200g
1 year warranty

Conventional Systems : Bell


Manufacturers Code 521601full-1601 Fire bell 6 inch 24VDC F0197

6 Inch motorised bell 24Vdc, red (Centrifugal)


High sound output; up to 95dB(A)
Classic design
Simple installation
For fire or non fire use
Construction: Gong - steel, base - polycarbonate
Dimension: 152mm D x 63mm H
Weight 0.85Kg
1 year warranty

274 Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za
FIRE & GAS DETECTION Duct Detection : Duct Detector Addressable Systems : Panel

FIRE & GAS DETECTION


Manufacturers Code 53546-022APO XP95 Duct detector. For smoke in air in HVAC ducts. Needs detector F0687

Operates in air speeds of 0.5m/s to 20m/s


Transparent cover to view detector head LED
Integral smoke test port
3 year warranty

A81162 F2 F0753 ENA63002 03 F0707 ENA6300403 F0332


Manufacturers Code 53541-170APO Metal duct sampling tube F0688 Flush mount 2 loop AS fire panel with SYNCRO 2 Loop fire panel with Apollo 4 Loop fire panel Apollo protocol. Zonal
16 zonal LEDS protocol LEDS are optional
Apollo duct detection duct sampling tube - 762mm
Analogue addressable fire control panel - Analogue addressable fire control panel Analogue addressable fire control panel -
2 Loop 16 zone LEDs Apollo protocol - 2 Loop version 4 Loop version
Certification: BS EN54-2: BS EN54-4 Apollo protocol Apollo protocol
Enclosure details (mm): Surface 385W x Battery capacity: Up to 12Ah 0 Zone LEDs
310H x 90D Certification: BS EN54-2: BS EN54-4 Certification: BS EN54-2: BS EN54-4
No enable key Enclosure details (mm): Surface 500W x Enclosure details (mm): Surface 500W x
No printer 355H x 117D 355H x 117D

Beam Detector : Reflecting Beam Detector 1 year warranty No enable key


No printer
No enable key
No printer
0 Zone LED 1 year warranty
Manufacturers Code 29600-350 Reflective beam head and controller kit for up-to 40m F0705 1 year warranty

Firebeam reflective beam detector 5-40m


Continually corrects itself against building movement
Controlled and adjusted from ground level
1 year warranty

Manufacturers Code 29600-351 Reflective beam extender kit from 40m up-to 80m F0706

Firebeam extension kit from 40m - 80m


A651162 03 F0738 MH80162 M2 F0783 V81162M2 F0402
SYNCRO XT Analogue addressable 2 loop SYNCRO AS Marine certified 2 loop Hochiki Fitted with 2 Argus protocol loop cards
extinguishant panel protocol fire panel and 16 zonal LEDs
Analogue addressable extinguishant Marine certified analogue addressable Analogue addressable fire control panel
control panel - 2 Loops fire control panel - 2 Loop 16 zone LEDs - 2 Loop 16 zone version
Apollo protocol Hochiki protocol Argus Vega protocol
Manufacturers Code 29600-352 Reflective beam extender kit up-to 100m F0704 Syncro XT control panel Certification: BS EN54-2: BS EN54-4 Certification: BS EN54-2: BS EN54-4
Size(mm): 500 x 355 x 117 Enclosure details (mm): Surface 385W x Enclosure details (mm): Surface 385W x
Firebeam extension kit from 80-100m 310H x 90D
16 zone LEDs 310H x 90D
1 year warranty No enable key No enable key
No printer No printer
1 year warranty 1 year warranty

Addressable Systems : Panel


Manufacturers Code A81161 M2 SYNCRO AS - 1 Loop Apollo protocol panel with 16 zonal LEDs F0672

Analogue addressable fire control panel - 1 Loop 16 Zonal LEDs


Apollo protocol
Certification: BS EN54-2: BS EN54-4 ENV63004 03 F0365 MA80161 M2 MA80162 M2 F0710
Enclosure details (mm): Surface 385W x 310H x 90D
Kentec 4 loop Argus protocol panel. No SYNCRO AS Marine certified 1 loop Apollo SYNCRO AS Marine certified 2 loop Apollo
No enable key
zonal LEDs protocol fire panel - Complete with 16 protocol fire panel - Complete with 16
No printer
Analogue addressable fire control panel - zonal LEDs zonal LEDs
1 year warranty
4 loop version Marine certified analogue addressable Marine certified analogue addressable
Manufacturers Code A81162M2 2 Loop fire panel Apollo protocol with 16 zonal LEDS F0333 Argus Vega protocol fire control panel - 1 loop 16 zone LEDs fire control panel - 2 Loop 16 zone LEDs
0 Zone LEDs Apollo protocol apollo protocol
Analogue addressable fire control panel - 2 Loop 16 zone LEDs Apollo protocol Certification: BS EN54-2: BS EN54-4 Certification: BS EN54-2: BS EN54-4 Certification: BS EN54-2: BS EN54-4
Certification: BS EN54-2: BS EN54-4 Enclosure details (mm): Surface 500W x Enclosure (mm): Surface 385W x 310H x Enclosure details (mm): Surface 385W x
Enclosure details (mm): Surface 385W x 310H x 90D 355H x 117D 90D 310H x 90D
No enable key No enable key No enable key No enable key
No printer No printer No printer No printer
1 year warranty 1 year warranty 1 year warranty 1 year warranty

276 Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za 277
FIRE & GAS DETECTION Addressable Systems : Accessories Addressable Systems : Networking Cards

FIRE & GAS DETECTION


Manufacturers Code K553-16 16 Zone LED Extender kit for Syncro fire panel F0339 Manufacturers Code K555 Fault tolerant network card. Simple 2-wire loop connection plus earth F0342
16 Zone LED extender kit for Syncro panels Up to 64 nodes
1 year warranty High integrity protocol
Fully secure against short or open circuit faults
Simple 2-wire loop connection plus earth
Supports open ended networks for retrofit applications
Repeaters share network connection
Network wide test and disablement functions
Network wide cause and effect logic
Manufacturers Code K554-48 48 Zone LED Extender kit for Syncro fire panel F0340 1 year warranty

48 Zone LED extender kit for Syncro panels


1 year warranty
Addressable Systems : Accessories
Manufacturers Code K556P Modem module (PSTN) for use with Kentec SyncroAS and Syncro F0779

View devices near calibration limits


Manufacturers Code K554-96 96 Zone LED Extender kit for Syncro fire panel F0341 Plan maintenance visits
Retrieve event log
96 Zone LED extender kit for Syncro panels Dial in and observe reported faults
1 year warranty Assist commissioning from remote location
Avoid unnecessary call outs
Simple to install
Dongle protected access, for customers security
1 year warranty

Manufacturers Code K547 8 volt free changeover relay contacts (1Amp 30V DC) F0335

8 volt free changeover relay contacts (1Amp 30V DC) Manufacturers Code K768SYN Thermal printer retrofit for Kentec Syncro panels F0344
Relay operated indications
Retrofit printer kit for the Kentec Syncro range of control panels
Remote connection to panel via RS485 serial bus
Front loading version
Common footprint to other Syncro I/O board types
1 year warranty
All outputs programmable for cause and effects
Can be used with other Syncro I/O modules on the same panel
Compatible with Syncro AS panels
1 year warranty

Addressable Systems : Repeater Manufacturers Code G1001 Kentec GUIDE: Single panel graphics software package F0367

Choice of text, graphic, event list display when an event occurs


Versatile event analysis
Manufacturers Code K67000 M1 Syncro View local LCD repeater. No network card needed. F0345 Total history archive
Easy to programme
Large liquid crystal display (240 x 64 pixels) Secure system
High brightness LED indications Unlimited map linking & zoom facility
Internal sounder Support for 100s of graphics
Replicates all Syncro panel controls Display and control for multiple panels
Simple, two-wire serial connection 1 year warranty
Small, Syncro style enclosure
Removable electronics for easy installation
Low power consumption
1 year warranty Manufacturers Code G1004 Kentec GUIDE: Four panel graphics software package F0368

Choice of text, graphic, event list display when an event occurs


Manufacturers Code K68000 M1 Focus 3 button LCD repeater. Network card needed F0346 Versatile event analysis
Total history archive
Network LCD repeater panels Easy to programme
Syncro focus - 3 button version Secure system
Enclosure details (mm): Surface 330W x 255H x 90D Unlimited map linking & zoom facility
PSU not fitted Support for 100s of graphics
1 year warranty Display and control for multiple panels
1 year warranty

278 Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za 279
FIRE & GAS DETECTION Addressable Systems : Accessories Addressable Systems : Zone Expansion Card

FIRE & GAS DETECTION


Manufacturers Code K560 16 Channel input/output board F0334

16 channels (each channel configurable as input or output)


Inputs opto-isolated
Outputs open collector transistor
Simple 2 wire connection to control panel
Up to 32 boards supported per panel (512 input/output channels)
Multi drop RS485 communications
Can be used with other Syncro I/O modules on the same panel
G1008 F0369 G1016 F0370 G1032 F0371 Compatible with Syncro AS panels
Kentec GUIDE: Eight panel graphics Kentec GUIDE: Sixteen panel graphics Kentec GUIDE: Thirty two panel graphics 1 year warranty
software package software package software package
Choice of text, graphic, event list display Choice of text, graphic, event list display Choice of text, graphic, event list display
when an event occurs when an event occurs when an event occurs
Versatile event analysis Versatile event analysis Versatile event analysis
Total history archive Total history archive Total history archive Manufacturers Code K545 Four conventional detection zones can be monitored F0337
Easy to programme Easy to programme Easy to programme
4 monitored conventional detection zone inputs
Secure system Secure system Secure system
2 monitored sounder outputs
Unlimited map linking & zoom facility Unlimited map linking & zoom facility Unlimited map linking & zoom facility
Local power supply fault input
Support for 100s of graphics Support for 100s of graphics Support for 100s of graphics
RS485 comms connection to Syncro fire alarm panel
Display and control for multiple panels Display and control for multiple panels Display and control for multiple panels
Individual fault and operated indications for inputs and outputs
1 year warranty 1 year warranty 1 year warranty
Directly replaces a conventional control panel when integrating into an analogue
addressable system
Can be used with other Syncro I/O modules on the same panel
Compatible with Syncro AS
panels
1 year warranty

G1064 F0372
Kentec GUIDE: Sixty four panel graphics
GR2001 F0772
Add a single repeater package to Syncro
GR2004 F0556
Syncro Guide 4 repeater package for
Addressable Systems : Accessories
software package Guide software program
Choice of text, graphic, event list display Syncro GUIDE V3 repeater GUIDE Software - 4 repeater package Manufacturers Code B3558 115Vac input and 30Vac output Syncro transformer F0742
when an event occurs Providing repeater facility for any GUIDE Up to 4 GUIDE repeaters may be
Versatile event analysis system connected to a single GUIDE system Retrofit transformer for Syncro AS panels for 110Vac input (Mainly used on the mines)
Total history archive Single repeater package (Additional Easy to use
Easy to programme computer) Allows graphical information of fire
Secure system 1 year warranty events to be shown at alternative
Unlimited map linking & zoom facility locations
Support for 100s of graphics 1 year warranty
Display and control for multiple panels
1 year warranty

Modules and Interface : Repeater


Manufacturers Code K27101 Illuminated warning sign with internal sounder F0745

Illuminated signs using high intensity LED indicators


Enclosure: 1.2mm mild sheet steel
S187 F0671 K16000 L2 F0765 A4-DOC-BOX-R-FIRE F0814 Finish/colour: Lid & box - EPC (BS 00 A 05, mid grey fine texture)
KENTEC Software download cable for Fire document box. Slim design to match FIRE document box. Red with fire logo Text colour: Red on black
Syncro and SyncroAS panels Syncro and Sigma panels Wording: FIRE ALARM EVACUATE AREA (Bespoke messages)
Ideal for the safe keeping of important
Laptop to panel - upload/download lead Document enclosure Enclosure details (mm): Surface 300W x 195H x 50D
documents, log books and other
Suitable for all BS & EN Syncro and Syncro Matches design & colour scheme for 1 year warranty
paperwork for a buildings fire system
AS panels Sigma CP/XT & Syncro AS panel ranges Specifically branded for fire applications
Standard version The enclosure is low profile 50mm
Enclosure details (mm): Surface 385W x Lockable and is provided with 2 keys
310H x 60D 1.2mm Powder coated Steel
1 year warranty Physical size - 300mm x 235mm x 50mm
1 year warranty

280 Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za 281
Environmental Detection : Accessories

No Burn No Burn
VENTCROFT VENTCROFT
FIRE & GAS DETECTION
Manufacturers Code 470-12 Ground water sensor (1 probe included) 12Vdc operation F0719

12 Vdc water sensor (1 probe included)


Designed to allow water or any conductive non-flammable liquid to be detected with low XP
XPS
voltage and low current

Not Equivalent - Better!


Can monitor up to 2 sensing probes (470PB) simultaneously
Ideal for server rooms, basements, laundry rooms and kitchen or anywhere flooding is a
possibility and early warning is desirable to prevent damage
Selectable (Hi or low) sensitivity setting
Form C output relay THE FASTEST FIRE CABLE
1 year warranty
TO PREPARE FOR TERMINATION.
LPCB Ref. No. 682e/01 LPCB Ref. No. 682c/01
Manufacturers Code TS300 TS300 Hardwired temperature monitor B0674 Approved & Certified Approved & Certified

Allows simultaneous use of local and remote temperature probes, programmable Both XP & XPS ranges of NoBurn Fire Performance
hysteresis and audible alarm with silence timeout
cables are fully approved & certified by LPCB to
Illustrate the sensors flexibility in installation, programming and operation
1 year warranty
meet high levels of fire resistance, fire retardance
and emit low smoke and zero halogen gases.

NoBurn XPS Special range provides the standard NoBurn XP Premium range is additionally tested to
performance of a 30 minute duration when tested an enhanced performance, the XP range is approved
with fire and mechanical shock to EN 50200:2006 & tested to:-
Ph30, it is LPCB certified & tested to:-
Addressable Systems : Accessories EN 50200:2006 PH30
For 30 minutes at 830C (up to +40C) fire & mechanical
EN 50200:2006 PH30, PH60 & PH120
For 120 minutes (2 hours) fire at 830C (up to +40C) with
mechanical shock applied every 5 minutes throughout the 2
shock applied every 5 minutes throughout the 30 minute test. hour test.
Manufacturers Code 430SS Fits SYNCRO AS and SIGMA panels F0694
Note - This test conducted on one cable sample. Additionally NoBurn XP is approved to
Stainless steel weatherproof enclosure for fire panel EN 50200:2006 + Annex E 30 (tested with water applied)
Powder coated 30 minute test at 830C (up to +40C) with fire, mechanical
Both XP & XPS ranges are supplied with a shock applied every 5 minutes, water spray applied for final 15
See through window to view fire panel information 2
IP66
0.50mm drain wire. minutes.
1 year warranty
Note - Each test above is conducted on one cable sample.

Both XP & XPS ranges are also LPCB approved to the following additional test standards:-
220/24V BS 6387:1994, Clause 10 BS 6387:2013 Clause 6, 7 & 8 CWZ
Manufacturers Code 24VDC Relay coil. 10Amp contacts B1858
by meeting this standard NoBurn Fire Cable also complies with C = for 180 minutes (3 hours) at 950C (up to 40C) fire only.
24Vdc version EN 60332-1-2:2004. This test shows the NoBurn cable sheath W = for 30 minutes at 650C (up to 40C) fire with water spray
Current drain - 48mA energised self extinguishes so will not propagate fire. applied for final 15 minutes.
Normally open & normally closed relay contacts 10A @220VAC Z = for 15 minutes at 950C (up to 40C) with fire &
Reverse polarity protection EN 50267-2-1:1999 Zero Halogen Emissions mechanical shock applied every 30 seconds throughout the
Back emf protection Emits emissions of less than 0.5% of corrosive & acid gas when test.
Physical size - 37mm x 26m under fire conditions.
EN 61034-2:2005 Low Smoke Emission
Meeting at least 60% for residual light transmission while cable
Manufacturers Code ELM-FUSE-KIT Engineer fuse kit F0801 is under fire conditions.
ELM-FUSE-KIT (5 of each value)
Sturdy Colour Coded Plastic Reels Both Ranges Offer
20mm (Fast Blow); F500mA; F1A; F1.6A; F2A; F2.5A; F3.15A; F4A; F5A; F6.3A; F10A; 20mm
! Easy Handling, Damage, Weather and Water Resistant ! Easy to Install and Superb Working Flexibility
(Time delay); T1A; T2A; T3.15A; T5A; 32mm (Fast blow)
! Up to 12 Twists per metre for Data Protection
! Red, White, Black & Orange Outer Sheaths Available
2 2 2 2
! 1.0mm , 1.5mm , 2.5mm & 4.0mm (Nom.) Conductors
! 100m, 200m, 500m and Special Lengths Available
! Voltage Rating 300v/500v
! Suitable for Air Conditioning, Computer Control & Lift Doors
Manufacturers Code ELM-RES-KIT Resistor kit 30 x 9 common types (270 in total) ELM-RES-KIT Elmdene F0810 where Low Smoke & Zero Halogen is required
! MOQ may apply to some types & sizes
Housed in neat compartment plastic boxes they are labelled clearly for quick
! Duest Free- Ideal for Medical & Food Environments
identification of components.
ELM-RES-KIT (30 of each value)
SAVE YOURSELF TIME AND COST !
0
470R; 680R; 1K; 2K2; 3K9; 4K7; 6K8; 10K; 20K
Full BS 5839 & BS 7629
Fire Cable also available
YEARS
Manufactured in
United Kingdom E&OE

282 Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za
FIRE & GAS DETECTION Fire Alarm Cable : Accessories Addressable : Accessories

FIRE & GAS DETECTION


Manufacturers Code STI-6400 Exit Stopper for fire doors with 105dB battery driven sounder F0761

Exit Stopper multifunction door alarm - red


Helps prevent unauthorised exits/entries
95/105 dB alarm when activated
Set to sound for 30 seconds, 3 minutes or continuous
Can be used as an annunciator
VXS-210DR500 F0797 VXS-210DR F0798 VXP-210DRH F0748 Three year guarantee against breakage of polycarbonate in normal use (one year on electro
Fire resistant cable 2 core 1mm 500m roll Fire resistant cable 2 core 1mm 100m roll Fire resistant cable 2 core 1mm 100m mechanical and electronic components)
EN50200 Ventcroft EN50200 Ventcroft roll EN50200 136mm x 136mm x 50mm
PH30 2 core solid 1mm 500m roll EN5200 PH30 2 core solid 1mm 100m roll PH120 2 core solid 1mm 100m roll 1 year warranty
red EN5200 red EN50200 red
Complies with BS6387:1994 Clause Complies with BS6387:1994 Clause Complies with BS6387:1994 Clause
11CWZ and BS EN50200:2006 PH30 11CWZ and BS EN50200:2006 PH30 11CWZ and BS EN50200:2006 PH30, Manufacturers Code 2670 VON DUPRIN Emergency exit alarm lock F0726
Mechanical shock applied every 5 Mechanical shock applied every 5 PH60 & PH120
Secure, alarmed code-compliant protection for secondary exits
minutes through-out the test minutes through-out the test Mechanical shock applied every 5
Ideal for deterring theft in restaurants and retail establishments
Water spray applied for final 15 minutes Water spray applied for final 15 minutes through-out the 2 hour test
Designed to operate in a variety of environments
of test minutes of test Water spray applied for final 15
Armed and disarmed by key, using a standard rim cylinder
minutes of test
Door width range 914mm to 1219mm
Works off 9V battery or mains using a transformer
1 year warranty

Manufacturers Code 2609 Von Duprin double door strike F0732

Von Duprin 2609 double door strike - black for use with Von Duprin emergency exit alarm

VXP-210DR500M F0749 VXP-210DW F0750 VXP-215DRH F0762


Fire Resistant cable 2 core 1mm 500m Fire resistant cable WHITE 2 core 1mm Fire resistant cable 2 core 1.5mm 100m
EN50200 Ventcroft 100m roll EN50200 Ventcroft EN50200 Ventcroft
PH 120 2 core solid 1mm 500m roll PH120 2 core solid 1mm 100m roll PH120 2 core solid 1.5mm 100m roll
EN50200 red EN50200 white EN50200 red
Complies with BS6387:1994 Clause Complies with BS6387:1994 Clause Complies with BS6387:1994 Clause
11CWZ and BS EN50200:2006 PH30, 11CWZ and BS EN50200:2006 PH30, 11CWZ and BS EN50200:2006 PH30,
PH60 & PH120 PH60 & PH120 PH60 & PH120 Manufacturers Code D50-240HW 240 Vac, 50kA, SPD
Mechanical shock applied every 5 Mechanical shock applied every 5 Mechanical shock applied every 5
240 VAC, 50kA, Surge Protection Device
minutes through-out the 2 hour test minutes through-out the 2 hour test minutes through-out the 2 hour test
Type 1 UL1449 3rd Edition listed
Water spray applied for final 15 Water spray applied for final 15 Water spray applied for final 15
1 year warranty
minutes of test minutes of test minutes of test

Manufacturers Code DTK-CMHWMOUNTSM Small mounting plate for HW/CM series

Small mounting plate for HW/CM series


VCA-C6SR F0799 VCA-C7SR F0756 VCA-S8DR F0759 1 year warranty
PH30 Red fire resistant cable clip for PH30 Single cable P clip for PH120 1 & 1.5mm Double cable saddle for PH120
1 & 1.5mm. Pack of 50 Ventcroft bag of 50 Ventcroft 1mm bag of 50 Ventcroft
Meets the cable support requirements Meets the cable support requirements Meets the cable support requirements
ofBS 5839-1:2013 ofBS 5839-1:2013 ofBS 5839-1:2013

One Stop Shopping


For Total Solutions Leading Brands in Stock Every Day at ADI!
Manufacturers Code DTK-2MHLP24BWB 24V, 2 Pair, hybrid field replaceable suppression module w/ hardwired base

24V, 2 Pair, hybrid field replaceable suppression module w/ hardwired base


1 year warranty

VCA-S9DR F0758
Double cable saddle for PH120
1.5mm bag of 50 Ventcroft
Meets the cable support requirements
In our branches, over the phone or through our catalogues
ofBS 5839-1:2013

284 Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za 285
Addressable Detector : Optical Smoke
The XP95 range of analogue addressable fire detectors is advanced in design, improved in performance and has unique

FIRE & GAS DETECTION


features that benefit the installer and the end user.
The detectors have been carefully researched and developed by the Apollo design team and the range has undergone
rigorous testing to ensure that it meets not only European and other standards but also the demands of todays high
technology environments.

Protecting Lives and


XP95 detectors provide an alarm facility that automatically puts an alarm flag on the data stream and reports its address
when the pre-set EN54 thresholds are exceeded.

Manufacturers Code 55000-600APO Optical analogue detector XP95 F0321

Property Worldwide Optical technology - responds quickly to slow smouldering fires


Well suited for bedrooms and escape routes
CE marked
Self- extinguishing white polycarbonate case
Unaffected by wind or atmospheric pressure
Supply voltage: 17 to 28 Volts dc

...for a Lifetime
Operating temperature: -20C to +60C
IP23D rating
3 year warranty
Apollo Fire Detectors
manufactured products
save lives and protect 55000-660APO
Manufacturers Code XP95 Black optical detector. Suitable for night clubs and theatres F0692
property around
the globe from the Responds well to slow-burning, smouldering fires
risk of fire; a huge Well suited for theatres and night clubs
responsibility we take Unaffected by the wind or atmospheric pressure
very seriously. 3 year warranty

Our Product Lifetime


Guarantee provides
a warranty on our
products, which for Manufacturers Code 58000-600MAR Discovery analogue addressable marine optical detector F0715
detectors, alarm devices,
interfaces and call Discovery marine optical smoke detector
points is 10 years (CO Responds well to slow-burning, smouldering fires
Suitable for bedrooms and escape routes
detectors, 5 years).
Unaffected by wind or atmospheric pressure
Remote test feature
The guarantee supports Rejection of transient signals
our recommended 3 year warranty
working life of
the product and
further endorses our Manufacturers Code TC806E1012-IV Honeywell optical analogue detector F0259
commitment to our
customers in providing Analogue photoelectric smoke sensor
them with reliable, Plug-in type smoke sensors that combine a photo electronic sensing chamber with
addressable-analogue communications
quality fire detection
Designed for open area protection
products. Two LEDs on each sensor light to provide a local 360 visible sensor indication
*The Product Lifetime Guarantee is
Tested and certified to prEN54 part 7
subject to terms and conditions, please Height: 43 mm installed in B501 base
refer to our General Conditions of Sale.
Diameter: 102 mm
Weight: 115 g
1 year warranty

Manufacturers Code V100 V100 Argus optical detector F0349

Intelligent optical detector


High reliability and error detection
Short circuit isolators in each device
Line quality information
www.apollo-fire.co.uk/lifetime 1 year warranty

Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za 287
FIRE & GAS DETECTION Addressable Detector : Ionisation Smoke Addressable Detector : Optical Smoke

FIRE & GAS DETECTION


Manufacturers Code 55000-500APO XP95 Ionisation detector F0727 Manufacturers Code TC840MFES-IV Honeywell multi sensor detector F0074

XP95 Ionisation smoke detector Combined detector (smoke/heat)


Responds well to fast-burning, flaming fires Colour: Beige
Designed to operate in a variety of environments Diameter: 102 mm
Minimal effects from the temperature, humidity, atmospheric pressure Height: 66 mm
Well protected against electromagnetic interference over a wide frequency range 1 year warranty
Red LED alarm indicator
3 year warranty

Addressable Detector : Heat Addressable Detector : Detectors


Manufacturers Code 55000-400APO XP95 Addressable standard heat detector F0564 Manufacturers Code V200 V200 Argus multi detector. Photo/thermal F0350
Ideal in environments that are dirty or smoky under natural conditions Intelligent multi-criteria detector
Well suited for warehouses, loading bays and car parks Designed to meet the requirements of EN54-5 A1R and En54-7
Unaffected by wind or atmospheric pressure High reliability and error detection
An A2S device and will report an alarm at 55C Short circuit isolators in each device
3 year warranty 1 year warranty

Manufacturers Code 55000-401APO XP95 High temperature heat detector CS device 90C F0640

Ideal in environments that are dirty or smoky under natural conditions


Well suited for warehouses, loading bays and car parks
Unaffected by wind or atmospheric pressure Addressable Detector : Standard Base
High temperature detector reporting an alarm at 90C
3 year warranty
Manufacturers Code 45681-210APO Addressable base with XPERT address card F0324

XPERT Addressing
Manufacturers Code 58000-400MAR Discovery analogue addressable marine heat detector F0714 One way fit of detector
Locking feature to prevent unauthorised detector removal
Discovery marine heat detector 3 year warranty
Ideal in environments that are dirty or smoky
Unaffected by wind or atmospheric pressure
Remote test feature
3 year warranty

Manufacturers Code 45681-209APO XP95 Deep base for additional wiring space F0793
Manufacturers Code V350 V350 Argus thermal detector F0351 Enables surface wiring
XPERT addressing
Intelligent thermal detector
Locking feature to prevent unauthorised detector removal
Designed to meet the requirements of EN54-5 A1R and EN54-5BS
3 year warranty
Provides high reliability and error detection
Short circuit isolators in each device
1 year warranty

Manufacturers Code 45681-361APO XP95 Black base for black detector F0693
Addressable Detector : Detectors Standard XP95 Black base to go with the black version optical/ionisation smoke detectors.
3 year warranty

Manufacturers Code 55000-885APO XP95 Multisensor detector. Smoke and heat F0627

Sensitive to a wide range of fires


Well suited for environments such as hotel bedrooms
Unaffected by wind or atmospheric pressure
3 year warranty

288 Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za 289
FIRE & GAS DETECTION Addressable Detector : Standard Base Addressable Systems : Sounder Beacon Base

FIRE & GAS DETECTION


Manufacturers Code 45681-210MAR Discovery analogue addressable marine detector base F0713 Manufacturers Code 45681-330APO Loop powered sounder - beacon - base with isolator F0665

Discovery marine mounting base Two volume ranges 55-75dB(A) and 75-91dB(A)
XPERT addressing Visual indicator flash rate of once per second
One way fit Synchronisation of alert and evacuate tones
Locking feature to prevent unauthorised removal Synchronisation of visual indicator flash
3 year warranty Individual and group addressing
Unique acoustic and visual indicator self-test
Built-in isolator
3 year warranty
Manufacturers Code B501AP-IV Base for Honeywell detectors F0033

Detector base
Colour: Ivory (RAL9001)
Diameter: 102 mm
Addressable Detector : Accessories
Height: 22.5 mm
Weight: 38 g Manufacturers Code 58000-300 Discovery carbon monoxide detector
1 year warranty
Discovery carbon monoxide detector
Enhanced detection capability
Ideal for smouldering fires
Less susceptible to false alarms caused by steam than smoke detectors
Addressable Systems : Standard Base Five response modes
Remote test feature
3 year warranty
Manufacturers Code VB100 VB100 - Argus standard base F0419

Argus Vega universal base


Complete with secure and reliable cable terminations
For use with all 100 series intelligent detectors Addressable Systems : Accessories
1 year warranty

Manufacturers Code 38531-771 Spare address card for Discovery and XP95 detector base F0561

Simplifies and speeds up installation and commissioning


Uses patented proven technology
Address remains the same, no matter how often detectors are replaced
Flexibility to create any address

Addressable Systems : Isolating Base Blank XPERT Card

Manufacturers Code 45681-284APO XP95 Isolating base for detecting short circuits F0646

Senses and detects short-circuit faults on Discovery loops and spurs Manufacturers Code 53832-070APO XP95 Mini disc remote indicator F0576
Up to 20 detectors or their equivalent load, may be installed between isolating bases
High brightness LED Can be used across the entire Apollo range
Detects wiring short-circuits Small and discrete
Minimises disruption from short circuits Anti-tamper screw to protect against unauthorised removal
3 year warranty 1 year warranty

Addressable Systems : Sounder Base


Manufacturers Code 45681-277APO XP95 Integrated base sounder with isolator 55-75dB & 75-91dB F0599
Addressable Sounder and Strobe : Accessories
Two tones 45681-293
Manufacturers Code Red cap for all base sounders using S65, XP95 or Discovery F0656
Two volume ranges 55-75dB(A) and 75-91dB(A)
Individual and group addressing Apollo locking red cap
Unique acoustic self-test Dimensions: 110 x 9mm
Built-in isolator Weight: 20g
In-door use
3 year warranty

290 Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za 291
FIRE & GAS DETECTION Addressable Sounder and Strobe : Accessories Addressable Detector : Flame Detector

FIRE & GAS DETECTION


Manufacturers Code 45681-292 White cap for Apollo base sounders/beacons Manufacturers Code 55000-023 XP95 Base mount flame detector UV/IR

White locking cap Intelligent base mounted UV IR flame detector


Dimensions: 100 x 9mm Responds to stationary flames with no flicker
Weight: 20g Sensitive to UV and low-frequency flickering IR radiation emitted by flames during
combustion
Compact flame detector which fits into Discovery or XP95 bases
Loop-powered
False alarms due to electrical discharges from lightning or arc welding and flickering sunlight
are minimised
3 year warranty

Duct Detection : Duct Detector


53546-022APO Manufacturers Code 55000-024APO XP95 Base mounted triple IR flame detector F0658
Manufacturers Code XP95 Duct detector. For smoke in air in HVAC ducts. Needs detector F0687

Operates in air speeds of 0.5m/s to 20m/s Responds to stationary flames with no flicker
Transparent cover to view detector head LED Sensitive to low-frequency flickering IR radiation emitted by flames during combustion
Integral smoke test port Compact flame detector which fits into Discovery or XP95 bases
3 year warranty Loop-powered
False alarms due to factors such as flickering sunlight are avoided by a combination of filters
and signal processing techniques
3 year warranty

Manufacturers Code 55000-020APO XP95 Intelligent triple IR flame detector (IR3) F0711

Loop-powered

Beam Detector : Reflecting Beam Detector Sensitive to flickering IR radiation


Detects through films of oil, dust, water and ice
Responds to flickering flames, including those invisible to the naked eye
False alarms due to lighting or flickering sunlight are minimised
Manufacturers Code 29600-350 Reflective beam head and controller kit for up-to 40m F0705 Compatible with Discovery and XP95 protocols
3 year warranty
Firebeam reflective beam detector 5-40m
Continually corrects itself against building movement
Controlled and adjusted from ground level
Use switch monitor or I/O to interface it to an addressable loop
1 year warranty
Manufacturers Code 55000-021APO XP95 Triple IR flameproof flame detector F0635

Loop-powered
Sensitive to flickering IR radiation
Manufacturers Code 29600-351 Reflective beam extender kit from 40m up-to 80m F0706 Detects through films of oil, dust, water and ice
Firebeam extension kit from 40m - 80m Responds to flickering flames, including those invisible to the naked eye
False alarms due to lighting or flickering sunlight are minimised
Compatible with Discovery and XP95 protocols
3 year warranty

Manufacturers Code 29600-458 Flame detector mounting bracket F0790


Manufacturers Code 29600-352 Reflective beam extender kit up-to 100m F0704
The base mounted flame detector bracket combines a bracket
Firebeam extension kit from 80-100m and deckhead mounting box.

292 Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za 293
FIRE & GAS DETECTION Flame Detectors : Flame Detector Addressable Systems : Call Point

FIRE & GAS DETECTION


Manufacturers Code 29600-203 Flame detector multi orientation mounting bracket F0634

The flame detector bracket is an optional accessory for the flame detectors
Stainless steel mounting bracket adjustable in two axis
Not suitable for base mounted flame detectors
Allows flame detector to be mounted in any orientation

VCP100 F0348 MCP5A-RP03FG-K01 F0382 55200-908APO F0781


VCP100 Argus resettable call point Honeywell protocol with EN54 markings. XP95 Call point with isolator
Glass element.
Manufacturers Code 29600-228 Flame detector weather shield F0747 Intelligent resettable call point - red Unique Plug & Play installation concept XP95 Manual call point with isolator
Designed to meet the requirements of Total Flex-Ability in the choice of EN54-11 and EN54-17 approved
Stainless steel weather shield for flame detector EN54-11 operating element E-Z fit connectors
Protects against water ingress Provides high reliability and error Enhanced aesthetics and compact design Front facing addressing without the
Protects sensor from direct sunlight detection Humidity: 93 3% non-condensing need to detach the back box
Short circuit isolators in each device Operating temperature: -100C to +550C A unique, ergonomically designed key
Addressable via VPU100 programmer Storage temperature: -100C to +550C for resetting and front cover removal
1 year warranty Ingress protection (IP) Rating: IP24D Backward compatibility and retro-fit
Fully approved to the latest standards Resettable element
Backward compatibility 3 year warranty
CPD approved
1 year warranty
Manufacturers Code 29600-226 Flame detector test unit and case F0633

Mimics the characteristics of real flames


Wide spectral output UV, visible, near IR, mid-IR
Tests many flame sensors types UV, UV/IR, UV/IR2, IR3, IR2, IR
Portable with rechargeable NiCd battery pack and charger
Selectable optical output type - Constant illumination, regular flashing sources (range of
frequencies), Irregular flickering sources (resembling flames)
Selectable optical output intensity with LED bar graph indication
Range typically 3 metres and beyond 58200-908APO F0323 58200-951 58100-950APO F0612
30 Second timeout on each test Call point addressable Discovery red XP95 Weatherproof manual call point Discovery manual call point
1 year warranty surface mount with isolator complete with isolator IP67 weatherproof IP67
EN54-11 Approved (EN54-17 approved Waterproof addressable manual call IP 67 rated
for isolator version) point with isolator red Plug and play terminal connections for

Addressable Systems : Accessories E-Z fit connectors


Front facing addressing without the
IP67 rated
EN54-17 approved
fast wiring
Continuity link for wiring test before
need to detach the back box E-Z fit connectors commissioning
Manufacturers Code 53832-030 Discovery detector programmer F0731 A unique, ergonomically designed key Front facing addressing without the Reports an alarm in under 0.2 seconds
for resetting and front cover removal need to detach the back box Resettable element
Portable test and configuration tool for Discovery smoke and heat detectors Backward compatibility and retro-fit A unique, ergonomically designed key 3 year warranty
Look up the date of manufacture 3 year warranty for resetting and front cover removal
Check the drift compensation value Dimension/weight:
Display and change the operating mode 110mmx110mmx74mm / 324g
Select/de-select LED flash mode 3 year warranty
Tests detectors
Reads approval codes
1 year warranty

New products
Addressable Call Point : Call Point
58100-975MAR
always in stock
Manufacturers Code 58100-971MAR Discovery analogue addressable marine manual call point F0716 Discovery marine call point water ADI continually expands its portfolio with the
proof IP67
Discovery marine manual call point latest products and technologies.
Order
Approved for use in indoor marine applications such as cruise liners Discovery marine waterproof manual
Reports an alarm in under 0.2 seconds call point
Plug and Play terminal connections for fast wiring
Allow wiring continuity testing before fitting
Designed for use outdoors and in places
where moisture can occur
www.adiglobal.com/za NOW!
Resettable element Compliant with EN54-11 0860 22 55 23 or +27(0) 11 574 2500
3 year warranty Can be used with the Discovery
marine range
3 year warranty

294 Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za 295
FIRE & GAS DETECTION Addressable Call Point : Accessories Addressable Call Point : Accessories

FIRE & GAS DETECTION


Manufacturers Code 44251-175 Apollo manual call point hinged cover for new Apollo range F0771 Manufacturers Code SCS070 Pack of ten spare test keys for KAC MCP A0740

Apollo manual call point transparent covers Call point test keys. Packets of 10
Can be fitted to all Apollo manufactured manual call points to add further protection against
accidental operation

Manufacturers Code 44251-176APO Apollo manual call point reset keys. Set of 10
Manufacturers Code P056 P056 - KAC Hinged cover seal for manual call point. Pack of 5 A0520
Manual call point reset keys for the new range of Apollo manual call points.
Call point cover anti tamper seals
For use with the new type KAC call points and covers
Pack of 5

Manufacturers Code KG1 X 10 Pack of ten spare glass elements F0045

Spare EN54 break glass for all KAC call points - pack of 10
Weight: 120g (10 pieces)

Manufacturers Code STI-15D20ML STI Eurostopper multi kit F0813

MCP Protective cover helps prevent malicious or accidental false fire alarms
Comes with red and green inserts
Manufacturers Code PS210 Resettable plastic element for KAC manual call point A0759 1 year warranty

PS210 Resettable element


Flexible element for use on KAC MCP

Manufacturers Code STI/BS STI/BS Breakable seals F0812


Conventional Call Point : Accessories Seals for Eurostopper

Manufacturers Code PS200 KAC Transparent protective hinged cover for manual call point F0562

Hinged plastic call point cover for fire alarm call points
Very easy to install

Sa ve Mo re
Addressable System : Strobe
Manufacturers Code 55000-009APO XP95 Open area beacon with isolator IP65 F0629

For use with XP95 & Discovery systems


Self-test fault monitoring
u Monthly Sales Flyer offers super savings! IP65 rated
u Hot Deals for a limited time only Individual and group addressing
u Sign up to receive your personal copy by email Synchronisation of flashes
Order Comes with isolating base as standard

www.adiglobal.com/za 0860 22 55 23 or +27(0) 11 574 2500 NOW! Loop-powered


Red lens
3 year warranty

296 Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za 297
FIRE & GAS DETECTION Addressable Sounder and Strobe : Strobe Addressable Systems : Sounder Beacon

FIRE & GAS DETECTION


Manufacturers Code 55000-877APO XP95 Loop powered beacon - needs XP95 base F0664 Manufacturers Code 55000-005APO XP95 Intelligent open area sounder/beacon. 92/100dB IP65 Weatherproof F0595

High intensity LEDs Self-test monitoring


More reliable than Xenon visual indicators Choice of tones on standard device: Apollo, slow whoop and DIN
Automatic LED check Two volume settings 92dB(A) and 100dB(A)
Lockable Individual and group addressing
Wide angle of visibility Synchronisation of tones and flashes
Enables DDA compliance Built in isolator
Synchronised flash Loop-powered
Can be used with Discovery or XP95 3 year warranty
3 year warranty

Addressable Sounder and Strobe : Horns (Sounders) Addressable Sounder and Strobe : Sounder Beacon
Manufacturers Code 55000-278APO XP95 Loop powered open area sounder 92dB(A)/100dB(A) Indoor F0601 Manufacturers Code 58000-005 Discovery open area sounder/beacon IP65 100dB(A)
Choice of tones: Apollo, slow whoop and DIN Discovery open-area sounder visual indicator
Two volume settings 92dB(A) and 100dB(A) Designed for use in indoor and outdoor areas
Synchronisation of tones 15 tones
Individual and group addressing Individual control of the sounder and visual indicator
Loop powered Volume and tone settings can be selected from the control panel
Red or white options Tones can be used for other purposes in addition to warning of fire, making the device ideal
IP21C rated for use in schools etc.
3 year warranty Soft start option, ideal for hospitals and nursing homes
Group and global control for increased response time
Manufacturers Code 55000-274APO XP95 Outdoor loop powered sounder IP66. 100 / 92dB F0575
3 year warranty
Updated to include choice of tones: Apollo, slow whoop and DIN
Two volume settings 92dB(A) and 100dB(A)
Synchronisation of tones
Individual and group addressing
Loop powered
Addressable Sounder and Strobe :
Red colour
IP66 rated
Horn (Sounder)/Strobes (Beacons)
3 year warranty
Manufacturers Code 55000-293 Addressable multi tone open area sounder/beacon/isolator indoor

Multi tone open area sounder beacon (red) with isolator


Addressable Systems : Sounder Choice of tones on standard device: Apollo, Slow Whoop and DIN
Two volume settings 92dB(A) and 100dB(A)
Synchronisation of alert and evacuate tones
Manufacturers Code VLS100 VLS100 Argus wall sounder F0358 Individual and group addressing
IP21C
Addressable wall sounder 3 year warranty
Designed to meet the requirements of EN54-3
Provides high reliability and error detection
Short circuit isolators in each device
Addressable via VPU100 programmer
1 year warranty
Addressable Sounder and Strobe : Sounder Beacon
Addressable Sounder and Strobe : Sounder/Strobes Manufacturers Code 55000-298APO XP95 Open area sounder/beacon weatherproof IP66 92dB & 100dB(A) isolated F0623

Choice of tones on standard device: Apollo, slow whoop, and DIN


Manufacturers Code 55000-374MAR Marine multi-tone open-area sounder. Weatherproof IP67 F0808 IP66 rated
Two volume settings 92dB(A) and 100dB(A)
NOT compatible with systems using Discovery Sounders!
Synchronisation of alert and evacuate tones
Marine multi-tone open-area sounder (Weatherproof ), red
Individual and group addressing
Choice of tones on standard device: Apollo, slow whoop and DIN
Built in isolator
IP67 rated
3 year warranty
Synchronisation of tones
Individual and group addressing
Non-isolated
Output 100dB(A)
3 year warranty

298 Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za 299
FIRE & GAS DETECTION Addressable Sounder and Strobe : Sounder/Strobes Addressable Systems : Accessories

FIRE & GAS DETECTION


Manufacturers Code 55000-398MAR Marine weather proof sounder/beacon IP66. Up-to 100dB F0807

Marine multi-tone open-area sounder beacon with isolator (Weatherproof ), red


Choice of tones on standard device: Apollo, slow whoop and DIN
IP66 rated
Synchronisation of Alert and Evacuate tones
Individual and group addressing
Built in isolator
Output 92 or 100dB(A)
3 year warranty 55000-847APO F0590 55000-875APO F0642 55000-803
XP95 input/output unit surface mounted XP95 Mains switching input/output unit. XP95 DIN Rail input/output unit
5A @ 250Vac resistive
It can report fault, switch open and DIN-Rail input/output unit
switch closed levels Supervises one or more normally-open It can report fault, switch open and
Three visible LEDs switches connected to a single pair of switch closed levels
Loop-powered cables Three visible LEDs
Addressable Systems : Accessories Capable of switching up to 30V at 1A
resistive
Three visible LEDs
Capable of switching 250Vac at up to 5A
Loop-powered
Capable of switching up to 30V at 1A
3 year warranty Resistive load resistive
3 year warranty Operates at 17-28VDC with protocol
Manufacturers Code 55000-760APO XP95 Mini switch monitor Din rail mount
voltage pulses of 5-9V
Designed to monitor state of 1 or more single-pole, volt-free contacts Dimension/weight:
Short circuit isolator as standard 110mmx107mmx20mm / 95g
39mm x 39mm x 20mm F0643 3 year warranty
3 year warranty

Manufacturers Code 55000-843APO XP95 Switch monitor F0651

Four input states - normal, fault, pre-alarm and alarm


Two visible LEDs
Loop-powered
55000-797APO F0709 55000-588APO F0655 55000-845APO F0782
3 year warranty
DIN rail mains input/output unit XP95 3 Channel input/output unit Conventional zone monitor for addressable
panels
It can report fault, switch open and Supervises one or more normally open
switch closed levels switches on each of the three inputs The Zone monitor powers and controls
Three visible LEDs Loop-powered the operation of a zone of up to 20 Apollo
Capable of switching up to 8A at 250V AC Capable of switching up to 30V at 1A Series 65 fire detectors from a Discovery
Fits a standard 35mm DIN-Rail resistive on each of the three outputs or XP95 loop.
Manufacturers Code 55000-849APO XP95 Output unit, isolated and surface mount F0645 3 year warranty 3 year warranty 3 year warranty

Output unit with isolator


The output unit provides a voltage free single pole, changeover relay output

Sa ve Mo re
It is a simplified version of the input/output unit without circuitry for monitoring inputs
Capable of switching up to 30V at 1A resistive load
3 year warranty

Expanded monthly
sales flyer offering
pages of savings
Manufacturers Code 55000-771MAR Discovery analogue addressable marine DIN rail output unit F0717
55000-852 55000-181MAR F0712
Marine DIN-Rail output unit XP95 Sounder control unit DIN Rail marine sounder controller
u Monthly Sales Flyer
Provides a voltage-free single-pole, change-over relay output.
Sounder control unit Marine DIN-Rail sounder controller (8 offers super savings!
Capable of switching up to 30V at 1A
Fits onto a standard 35mm DIN-Rail Allows sounders to be operated Amperes) u Hot Deals for a
3 year warranty continuously or be pulsed; 1 second on, Allows sounders to be operated limited time only
1 second off continuously or be pulsed, 1 second u Sign up to receive your
May be synchronised with loop on, 1 second off personal copy by email
sounders May be synchronised when in pulsed Order
3 year warranty operation NOW!
External supply monitoring www.adiglobal.com/za
Will accept a load of 8A
3 year warranty 0860 22 55 23 or +27(0) 11 574 2500

300 Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za 301
FIRE & GAS DETECTION Protective Covers : Accessories Detector Test Equipment : Canned Air

FIRE & GAS DETECTION


Manufacturers Code PS200 KAC Transparent protective hinged cover for manual call point F0562 Manufacturers Code SOLO A7-001 Smoke detector cleaner F0206
Hinged plastic call point cover for fire alarm call points Solo A7 Detector Duster
Very easy to install The Solo A7 provides a fast and effective way of removing dust and dirt from the detector.
Non-flammable
Powerful
Simple to use
Non-abrasive

Manufacturers Code P056 P056 - KAC Hinged cover seal for manual call point. Pack of 5 A0520

Call point cover anti tamper seals Detector Test Equipment : Tester
For use with the new type KAC call points and covers
Pack of 5
Manufacturers Code 101-001 Fibreglass extension pole for additional 1.3m reach F0647

SOLO 101-001 No Climb fibreglass extension pole (1.13 meters)


Exceptionally light weight
Non conductive material
Strong & durable fibreglass
Manufacturers Code STI-15D20ML STI Eurostopper Multi kit F0813 Can be used with all SOLO attachments
Use with tools up to 2.5 meters (Including Height of Man)
MCP Protective cover helps prevent malicious or accidental false fire alarms
Comes with red and green inserts
Manufacturers Code 100-001 Telescopic pole - 4.5 metres F0722
1 year warranty
SOLO 100-001 No Climb fibreglass 4 section telescopic pole (4.5 meters)
SOLO 100/108 telescopic poles
Exceptionally light weight
Non conductive material
Strong & durable fibreglass
Manufacturers Code STI/BS STI/BS Breakable seals F0812 Can be used with all SOLO attachments
Use with tools up to 6 meters (including height of man)
Seals for Eurostopper Add SOLO 101-001 extension poles to reach 9 meters (including height of man)

Manufacturers Code 330-001 Aerosol smoke and CO dispenser F0721

Maximum height : Up to 9m using Solo extension poles


Operating features : Swing frame for difficult to access detectors
Designed for smoke detector testing at varying heights
Constructed from strong, durable, yet lightweight materials
Can be used with either Solo telescopic or extension poles
Robust design
Detector Test Equipment : Canned Smoke Light touch activation for use on false ceilings
Can be used at any angle
1 year warranty
Manufacturers Code SOLO A3-001 Smoke tester spray 250ml F0205 Manufacturers Code 200-001 Universal detector extraction and insertion tool F0648
Solo A3 Smoke detector tester SOLO 200-001 No Climb universal detector removal and insertion tool
Provided in a 250ml canister it is designed for use with the Solo 330 and Solo 332 dispensers. Attaches to the SOLO100/108 & 101 pole systems
UL & ULC listed Quick and easy removal & insertion of detectors.
Detector manufacturer endorsed Size adjustable to suit most detectors
Non-flammable Tool remains level from all angles
Oil-free formulation Ideal for detectors on angled ceilings
No lasting residue Note:- Poles sold separately - This is sold as an extractor tool only
Fast activation and clearing time 1 year warranty

Manufacturers Code Solo C3-001 CO Detector tester Manufacturers Code 424-101 Heat detector test tool for 220 to 240Vac mains input F0723

SOLO C3-001 Solo CO (Carbon monoxide) tester aerosol 250ml Solo 424 Heat detector tester (mains powered)
For use in the Solo series detector tester aerosol dispenser Suits fixed temperature rate of rise and combination detectors up to 90C
Rapid activation times
Lightweight and simple to use
Universal suitable for use on most detectors
Designed for use at height and at angles
Supplied with 5m cable (additional 5m cables available)
1 year warranty

302 Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za 303
FIRE & GAS DETECTION Detector Test Equipment : Tester Detector Test Equipment : Canned Smoke

FIRE & GAS DETECTION


Manufacturers Code 461-101 Cordless heat tester kit F0611 Manufacturers Code Smokesabre Eco responsible detector tester with no harmful residue F0780

Solo 461 cordless heat detector tester Faster detector activation and clearing
Battery powered Lowest cost per test
No cables or cords completely portable The end of harmful residue - risk is designed out with the sabre
Directs heat straight at detector Silicone free testing
Suits fixed temperature and rate of rise and combination detectors up to 194F / 90C Eco-responsibility - 100% bio-degradable sabre, ozone friendly, no CFCs and low GWP
Set detectors into alarm within seconds Detector manufacturer endorsement
Rechargeable even from vehicle UL and ULC Listed
Safe for use at low level or at heights 150ml can
1 year warranty
Manufacturers Code TS3-3PACK-001 Test smoke TESTIFIRE Smoke capsules 3 pack
Manufacturers Code 760-001 SOLO Battery baton for use with cordless heat tester tool F0735
TS3-3PACK-001 Testifire replacement smoke capsule
SOLO 760-001 No Climb battery baton Replacement pack of 3 testifire 1000 and 2000 smoke capsules
Replacement battery baton for use with SOLO 461-001 cordless heat detector tester

Manufacturers Code TC3-3PACK-001 Test fire TESTIFIRE CO capsules 3 pack


Detector Test Equipment : Tester TC3-3PACK-001 Replacement testifire CO capsules
Replacement pack of 3 Testifire 2000 CO capsules
Manufacturers Code 725-001 SOLO Mains and car charger for cordless heat tester battery F0736

Mains & in car charger for cordless heat detector battery batons
Battery batons supplied separately
1 year warranty

Aspirating Systems : Point Box Detectors


ICAM IAS by Xtralis aspirating smoke detector (ASD)provides a flexible solution to meet the unique needs of numerous normal

Detector Test Equipment : Accessories sensitivity applications including commercial spaces such as elevator shafts, the tamper-proof and unobtrusive requirements
of special accommodations, or can simply be used to replace spot (point) detectors in office environments. The IAS uses
clients existing FIP (fire indicator panel), infrastructure (smoke points), and provides the advantages associated with ASD
principles/application
Manufacturers Code 610-001 SOLO Test tool and pole carrying and storage bag F0725
Manufacturers Code IAS-1 ICAM Aspirating equipment ASD single channel. Needs detector and base F0701
SOLO 610-001 No Climb protective padded carrying/storage kit bag
Designed to fit all product range Single channel Class C, normal sensitivity fire detection
Separate pole bag included Multiple configuration options
Can be fitted with conventional or analogue detectors from leading manufacturers
Up to 100m of sampling pipe
Microprocessor controlled
Integral display and programmer
Field serviceable air filter
Adjustable aspirator speed with flow monitoring
IP65 enclosure
Detector Test Equipment : Tester 1 year warranty

Manufacturers Code IAS-2 ICAM Aspirating equipment ASD dual channel. Needs detectors and bases F0698
Manufacturers Code 1001-101 Testifire smoke and heat detector tester kit. Reduce test time by 66% F0804 Dual channel Class C, normal sensitivity fire detection
Multiple configuration options
Testifire 1001-001 smoke and heat detector test kit
Supports multiple detector types e.g. photoelectric and ionisation
Testing with one tool is faster and more productive
Up to 200m of sampling pipe (100m per pipe)
Less tools and equipment to carry around
Microprocessor controlled
Combined stimuli, delivers quicker activation times for combination detectors
Integral display and programmer
Unique clearing cycle provides rapid detector reset with no repeat alarms
Field serviceable air filter
Test times reduced by as much as 66% saving labour
Adjustable aspirator speed with flow monitoring
Fully reverse compatible with the Solo range of poles, battery batons and chargers.
IP65 enclosure
Ideal in any application, land, air and marine
1 year warranty
1 year warranty

304 Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za 305
Aspirating Systems : Point Box Detectors
The ICAM ILQ detector is a cost-effective Class A Aspirated Smoke Detector that meets the needs of small area applications of

FIRE & GAS DETECTION


up to 100 m. Examples include Telco switches, base stations controllers, remote base stations, small server rooms, data centre
containers, critical equipment, packaged HVAC units, anechoic chambers, pump houses, generator enclosures, signalling huts
and modular laboratories, just to name a few.
ILQ detectors are suitable for both high and normal sensitivity applications and offer many installation advantages in terms of
out-of-box operation, stand-alone functionality and simplified pipe network.

Manufacturers Code ILQ-100 Laser-based absolute smoke detection Aspiration detector with relays & USB

Laser-based absolute smoke detection


Event log
Monitored on board filter
Clean air barrier for optics protection
Up to 100m coverage
Up to 2 x 6m linear or up to 2 x 9m branched pipe lengths
4 Class A very early warning sample holes
Pre-alarm, alarm and fault relays
Autolearn facility
1 year warranty

ICAM ILS provides point based Laser Air-sampling Smoke Detection to meet the needs of numerous commercial and industrial
applications. ILS systems are suitable for both medium sensitivity and Class C applications.
Manufacturers Code ILS-1 ICAM Aspirating equipment with single channel laser detector F0699

Single channel early warning smoke detection


Up to 100 m per sampling pipe
Microprocessor controlled and programmed
Adjustable aspirator speed with flow monitoring
Integral display and programmer
Field serviceable air filter
IP65 enclosure
1 year warranty

Manufacturers Code ILS-2 ICAM Aspirating equipment with dual channel laser detector F0696

Single or dual channel smoke detection


Class C laser air-sampling point in a box smoke detection
Multiple detection strategies
100 m per sampling pipe
Microprocessor controlled and programmed
Highest fan capacity in its class
Integral display and programmer
Field serviceable air filter
1 year warranty

The Xtralis ICAM IFT-P Aspirating Smoke detector features an alarm sensitivity range from 0.001% to 20% obscuration/m.
The detector is classified as a Very Early Warning Smoke
Detector that can reliably detect fire at an early stage, and low to high concentrations of smoke over an area of up to 2000m2
The detector is configurable for a variety of environments, providing an ideal fire detection solution for telecommunications
and IT facilities.
Manufacturers Code IFT-PT ICAM High sensitivity aspirating equipment PICO TCP/IP. Class A F0697

Single zone
2 x 100m dual pipe air sampling
Class A, B, C 0.001% to 20% obscuration/m
4 Alarms - alert, action, fire 1, fire 2
2 x 100 m sampling pipes
Enhanced performance aspirator
Ethernet TCP/IP
RS232 ans RS485 Modbus integration
1 year warranty

Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za 307
FIRE & GAS DETECTION Aspirating Systems : Accessories Environmental Detection : Accessories

FIRE & GAS DETECTION


Manufacturers Code 06-AP10 ICAM Baffle for S65 and XP95 range of detectors F0695 Manufacturers Code 470-12 Ground water sensor (1 probe included) 12Vdc operation F0719

Cover for IAS detectors, used by Apollo series S65 or XP95 12 VDC Water sensor (1 probe included)
Designed to allow water or any conductive non-flammable liquid to be detected with low
voltage and low current
Can monitor up to 2 sensing probes (470PB) simultaneously
Ideal for server rooms, basements, laundry rooms and kitchen or anywhere flooding is a
possibility and early warning is desirable to prevent damage
Selectable (Hi or low) sensitivity setting
Form C output relay
1 year warranty
Manufacturers Code ISP-420 ILQ Surface mounting kit

Surface mount kit Manufacturers Code TS300 TS300 Hardwired temperature monitor B0674

Allows simultaneous use of local and remote temperature probes, programmable hysteresis
and audible alarm with silence timeout
Illustrate the sensors flexibility in installation, programming and operation
1 year warranty

The ILQ pipe kit provides 2 short pre-drilled pipe stubs and is an easy solution in situations where sampling is required at the
detector location only and where no additional sampling pipe is required

Manufacturers Code ISP-423 ILQ Kit comprising 2 pipe stubs with end-caps

Pipe kit (Metric) Manufacturers Code 470PB HONEYWELL water sensor probe for 470-12 F0737
Includes 2 pipe stubs
Includes 2 end caps Sensor probe for 470-12
1 year warranty

Xtralis pipe kits and associated Pre-Engineered design guide (doc.# 19315) simplify engineering design, procurement time
and costs by providing simplified applications design and a one-stop source for all components to form a complete and
operational air- sampling smoke detection system with minimal tools and knowledge. Manufacturers Code T280 T280R Remote probe for use with TS300 sensor B0698

Manufacturers Code PKIT15-E Aspirating equipment sample pipe kit 15m (no solvent cement) Remote temperature probe
1 year warranty
Aspirating pipe kit 15m includes 5 lengths of 3m sampling pipe, 20 x sockets, 10 x pipe clips,
10 x 90 radius bends, 10 x 45 elbows, 10 x end caps and 100 sampling point wrap around
labels.

Manufacturers Code PKIT30-E Aspirating equipment sample pipe kit 30m (no solvent cement)

Aspirating pipe kit 30m includes 10 lengths of 3m sampling pipe, 30 x sockets, 10 x pipe Intrinsically Safe : Flame Detector
clips, 10 x 90 radius bends, 10 x 45 elbows, 10 x end caps and 100 sampling point wrap
around labels.
Manufacturers Code 55000-063APO Intrinsically safe IR flame detector. ATEX & IECEx certified: II 1 G IP65 F0788

ATEX & IECEx certified: II 1 G


CENELEC/IEC Certified: Ga Ex ia IIC T4
Selectable output options: Conventional two-wire, 4-20mA, latching or non-latching
PKIT60-E Relay contacts - fire, fault and pre-alarm
Manufacturers Code Aspirating equipment sample pipe kit 60m (no solvent cement)
Class 1 sensitivity to EN54-10 detects 0.1m2 fire at 25m
Aspirating pipe kit 60m includes 20 lengths of 3m sampling pipe, 40 x sockets, 60 x pipe clips High optical interference immunity
10 x 90 radius bends, 10 x 45 elbow, 10 x end caps and 100 sampling point wrap around Selectable response speed
labels. Optical self-test
3 year warranty

308 Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za 309
FIRE & GAS DETECTION Flame Detectors : Flame Detector Flame Detectors : Flame Detector

FIRE & GAS DETECTION


Manufacturers Code 29600-226 Flame detector test unit and case F0633

Mimics the characteristics of real flames


Wide spectral output UV, visible, near IR, mid-IR
Tests many flame sensors types UV, UV/IR, UV/IR2, IR3, IR2, IR
Portable with rechargeable NiCd battery pack and charger
55000-025APO F0789 55000-019APO F0800 55000-024APO F0658 Selectable optical output type - constant illumination, regular flashing sources (range of
Conventional S65 UV flame detector Conventional IR3 flame detector XP95 Base mounted triple frequencies), Irregular flickering sources (resembling flames)
base mount for harsh environments IR flame detector Selectable optical output intensity with LED bar graph indication
Range typically 3 metres and beyond
Responds to stationary flames with Selectable output options: Conventional Responds to stationary flames with
30 Second timeout on each test
no flicker two-wire, 4-20mA, latching or no flicker
1 year warranty
Sensitive to UV radiation emitted by non-latching Sensitive to low-frequency flickering IR
flames during combustion Relay contacts - fire, fault and pre-alarm radiation emitted by flames
Compact flame detector which fits into Class 1 sensitivity to EN54-10 detects during combustion
Series 65 bases 0.1m fire at 25m Compact flame detector which fits into
Zone-powered High optical interference immunity Discovery or XP95 bases
3 year warranty Selectable response speed Loop-powered Intrinsically Safe : Optical Smoke
Optical self-test False alarms due to factors such as
Low power consumption flickering sunlight are avoided by
IP65 rated a combination of filters and signal Manufacturers Code 55000-640APO XP95 Intrinsically safe optical detector F0621
29600-203 Bracket is optional processing techniques
3 year warranty 3 year warranty Responds well to slow-burning, smouldering fires
For Intrinsically safe areas
3 year warranty

55000-020APO F0711 55000-021APO F0635 55000-023


XP95 Intelligent triple IR flame XP95 Triple IR flameproof flame detector XP95 Base mount flame detector UV/IR
detector (IR3)
Loop-powered
Loop-powered
Sensitive to flickering IR radiation
Intelligent base mounted UV IR
flame detector Intrinsically Safe : Detectors
Sensitive to flickering IR radiation Detects through films of oil, dust, water Responds to stationary flames with
Detects through films of oil, dust, water and ice no flicker
and ice Responds to flickering flames, including Sensitive to UV and low-frequency Manufacturers Code 55000-440 XP95 Intrinsically safe heat detector
Responds to flickering flames, including those invisible to the naked eye flickering IR radiation emitted by flames
those invisible to the naked eye XP95 IS Heat Detector
False alarms due to lighting or flickering during combustion
False alarms due to lighting or flickering Ideal for environments that are dirty or smoky under normal conditions
sunlight are minimised Compact flame detector which fits into
sunlight are minimised Unaffected by wind or atmospheric pressure
Compatible with Discovery and XP95 Discovery or XP95 bases
Compatible with Discovery and XP95 Must be used with barriers and Protocol Translators
protocols Loop-powered
protocols 3 year warranty
3 year warranty False alarms due to electrical discharges
3 year warranty from lightning or arc welding and
flickering sunlight are minimised
3 year warranty

Intrinsically Safe : Standard Base


Manufacturers Code 45681-215APO XP95 Intrinsically safe detector base F0620

Wide cable entry.


29600-458 F0790 29600-203 F0634 29600-228 F0747 Contains no electronic parts.
Flame detector mounting bracket Flame detector multi orientation Flame detector weather shield One way only fit
mounting bracket Low insertion force.
Large terminations.
The base mounted flame detector bracket The flame detector bracket is an optional Stainless steel weather shield for Lockable security fitting.
combines a bracket and deckhead accessory for the flame detectors flame detector White finish.
mounting box. Stainless steel mounting bracket Protects against water ingress Must be connected to a suitable safety barrier and protocol translator
adjustable in two axis Protects sensor from direct sunlight 3 year warranty
Not suitable for base mounted flame
detectors
Allows flame detector to be mounted in
any orientation

310 Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za 311
FIRE & GAS DETECTION Intrinsically Safe : Flame Detector Intrinsically Safe : Sounder

FIRE & GAS DETECTION


Manufacturers Code 55000-063APO Intrinsically safe IR flame detector. ATEX & IECEx certified: II 1 G IP65 F0788 Manufacturers Code DB7 PX212814 24VDC Intrinsically safe sounder ATEX Exia IIB & IIC 103dB IP66 F0760
ATEX & IECEx certified: II 1 G Exia, Zone 0, Zone 1 and Zone 2 use
CENELEC/IEC Certified: Ga Ex ia IIC T4 27 alarm tones
Selectable output options: Conventional two-wire, 4-20mA, latching or non-latching -55C to + 70C operating temperature range
Relay contacts - fire, fault, pre-alarm Corrosion free low maintenance
Class 1 sensitivity to EN54-10 detects 0.1m2 fire at 25m Voltage 24Vdc
High optical interference immunity Sound output 103dB max
Selectable response speed Construction: UV stabilised GRP
Weight: 1.0Kg
Optical self-test
1 year warranty
3 year warranty

Intrinsically Safe : Sounder and Beacon


Flame Detectors : Flame Detector
Manufacturers Code 29600-379 Syrex intrinsically safe sounder for zone 1, 2 & 3 IP65 F0787
Manufacturers Code 55000-021APO XP95 Triple IR flameproof flame detector F0635 49 tones
Adjustable sound
Loop-powered
100 dB (A)
Sensitive to flickering IR radiation
IP65 resistant to moisture
Detects through films of oil, dust, water and ice
ABS flame retardant UL94V0 & 5VA housing
Responds to flickering flames, including those invisible to the naked eye
ATEX approved
False alarms due to lighting or flickering sunlight are minimised
3 year warranty
Compatible with Discovery and XP95 protocols
3 year warranty

Intrinsically Safe : Sounder/Strobes


Intrinsically Safe : Call Point Manufacturers Code 29600-446 Syrex intrinsically safe sounder/beacon for zone 1, 2 & 3 IP65 F0786

49 tones
Manufacturers Code MCP1A-R470SF-K013-01IS Intrinsically safe MCP for conventional systems F0729 Adjustable sound
Semi-flush 100 dB (A)
IP65 resistant to moisture
Unique Plug & Play installation concept
ABS flame retardant UL94V0 & 5VA housing
Total Flex-Ability in the choice of operating element ATEX approved
Anti-tamper facility 3 year warranty
Enhanced aesthetics
Fully approved to the latest standards
Manufacturers Code DB6BBNR DB6 Bell ATEX EXLL 2GD explosion proof zone 1 & 2 up to 109dB(A) F0752
Backward compatibility
CPD Approved Zone 1 and Zone 2 use
1 year warranty Exd IIB T5
ATEX approved Ex II 2G
BASEEFA certified
Manufacturers Code MCP3A-R000SG-K013-01IS Intrinsically safe manual call point for conventional fire systems - indoor F0774 IECEx certified, Gb
IP65
N/O & N/C contacts 30VDC, surface mount
Certified temperature: 20C to +55C
Unique Plug & Play installation concept 2 cable entries
Total Flex-Ability in the choice of operating element Captive cover screws
Enhanced aesthetics 1 year warranty
Fully approved to the latest standards
Backward compatibility
CPD Approved
1 year warranty
Intrinsically Safe : Accessories
Manufacturers Code 55100-940APO XP95 I.S. Manual call point red IP67 weatherproof F0583 Manufacturers Code 55000-855APO XP95 Single channel intrinsically safe protocol translator F0581

Reports an alarm in under 0.2 seconds Protocol translator single channel


Waterproof with an IP67 rating
3 year warranty

312 Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za 313
FIRE & GAS DETECTION Intrinsically Safe : Accessories Fire Magnetic Door Holders : Accessories

FIRE & GAS DETECTION


Manufacturers Code 55000-856APO XP95 Dual channel intrinsically safe protocol translator F0637 Manufacturers Code UBDH24VDC UBDH24VDC Wall mount door retainer 50Kg F0659

Protocol translator dual channel Holding force of 50Kg +/- 15%


Self extinguishing ABS/PC UL94 VO
106 x 70 x 45mm
IP40
24Vdc with current consumption of 40mA
-5C to +40C maximum humidity 93%
1 year warranty

Manufacturers Code 29600-440 IS Loop powered sounder control barrier F0785

The AV Galvanic barrier is installed in the safe area and provides connection to audio visual
alarms in a hazardous area
1-channel isolated barrier
24 Vdc supply (loop powered)
Current limit 45 mA at 10 Vdc
Fire Systems : Power Supply Units EN54-4
Up to SIL3 acc. to IEC 61508
Kentec Syncro Power fully certified to EN54-4 power supplies provide a stable and fully regulated, true 24V output for fire
alarm system applications under all power conditions. The unique regulation techniques ensure that even when running on
Manufacturers Code 29600-378 IS Galvanic barrier for conventional fire systems F0728 standby batteries, a stable 24V supply is available to all parts of the system ensuring that all 24V powered devices connected
are supplied with optimum power. The powerful onboard microcontroller ensures that all battery types are conditioned with
IS range optimum, temperature compensated charging algorithms to maximise battery life and maintain batteries in top condition.
Can be installed in safe areas and ensures system integrity
Manufacturers Code K25250M2 EN54-4 Certified fire power supply 2.5 Amp 24Vdc F0764

Matches the Syncro Styling


Certification: BS EN54-4
Max. 12A/H batteries
PSU 2.5A
Enclosure details (mm): Surface 385W x 310H x 90D
Manufacturers Code 29600-098 XP95 Galvanic barrier - single channel F0582 1 year warranty
The Galvanic barrier is available in the XP95 IS range and the conventional IS range
It can be installed in safe areas and ensures system integrity

The new STX range of switch mode power supplies has been specifically designed for EN54 compliant fire systems. Available
in either 1A, 2A, 5A or 10A versions they are certified to EN54-4:1997, A1:2002 & A2:2006. The units include intelligent battery
charging using Elmdenes efficient EcoCharge technology, possess mains & battery monitoring with independent volt-free
outputs and also feature battery deep discharge protection in the event of a prolonged mains failure. The inclusion of LED
indicators provides quick diagnostics of the status of the power supply, while a variety of enclosures offer the installer a
choice of standby battery backup options.

Door Retainers : Standard Door Retainer Manufacturers Code STX2402-C Certified fire PSU 24Vdc 2A for 2 x 8Ah batteries

STX Range 24 Vdc EN54 power supply units


Specifically designed for EN54 compliant fire systems
Manufacturers Code VIR5024 FIRELOCK Stand alone wall mount door retainer, 50Kg 24Vdc A0718 27.6 Vdc output
Cost effective switch mode technology
Fire door electromagnetic lock Energy efficient
Fail-safe Intelligent battery charging and monitoring using Elmdenes EcoCharge technology
Wall mounted Rating: 2A, Max Battery Size: 2 x 12V 7Ah
Supplied with a universal armature Dimension: 275H x 330W x 80D
Holding force: 50Kg 1 year warranty
Power supply: 24V
Consumption: 80mA
1 year warranty
Manufacturers Code STX2405-E EN54 Certified fire PSU 24Vdc 5A for 2 x 17Ah batteries F0811
Manufacturers Code VIRP5/5024 FIRELOCK Stand alone floor mount door retainer, 50Kg 24Vdc A0717
STX Range 24 Vdc EN54 power supply units
Fire door electromagnetic lock Specifically designed for EN54 compliant fire systems
Fail-safe 27.6 Vdc output
Floor mounted Cost effective switch mode technology
Supplied with a universal armature Energy efficient
Holding force: 50Kg Intelligent battery charging and monitoring using Elmdenes EcoCharge technology
Power supply: 24V Rating: 5A, Max Battery Size: 2 x 12V 17Ah
Consumption: 80mA Dimension: 420H x 400W x 80D
1 year warranty 1 year warranty

314 Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za 315
FIRE & GAS DETECTION PSU & Batteries : Power Supply Units EN54-4 Gas Detection : Parking Detector

FIRE & GAS DETECTION


Manufacturers Code STX2410-H Fire PSU 24Vdc 10A 420Hx420Wx180D Manufacturers Code 58000-300 Discovery carbon monoxide detector

STX range 24 Vdc EN54 power supply units Discovery carbon monoxide detector
Specifically designed for EN54 compliant fire systems Enhanced detection capability
27.6 Vdc output Ideal for smouldering fires
Cost effective switch mode technology Less susceptible to false alarms caused by steam than smoke detectors
Energy efficient Five response modes
Intelligent battery charging and monitoring using Elmdenes EcoCharge technology Remote test feature
Rating: 10A, max battery size: 2 x 12V 38Ah 3 year warranty
Dimension: 420H x 420W x 180D
1 year warranty

Communication : Digital
PSU & Batteries : Accessories The TX Cellular Plus is a state of the art GSM/GPRS alarm transmitter that features dual network SIM functionality. It has seven
programmable positive or negative inputs and two relay outputs. Full programming and software updating via a computer
FB12-8G serial port. Full over-the-air programming of all functions via GPRS. User function programming via SMS.
Manufacturers Code Battery 12Vdc 8Ah B1552

Nominal voltage: 12V Manufacturers Code 17003 TX CELL Plus SMS only B1945
Rated capacity (20hr rate): 8Ah
Dimensions (LxWxH): 151 x 65 x 94 mm Option of single or dual card SIM
Total height: 100mm 7 programmable positive or negative inputs
Weight: Approx. 2.31kg 2 relay outputs
Full SMS functionality
SMS directly to cell-phones (up to 10 cell phone numbers)
User function programming via SMS
1 Year Warranty

Manufacturers Code 1218 Battery 12Vdc 18Ah B1551

Battery 12Vdc 18Ah

Manufacturers Code RS232 Program lead for cellular transmitter incl. dongle for computer. B1428

Program lead & software dongle

PSU & Batteries : Power Supply Units


Manufacturers Code PSU 24VDC-2.5A 2.5A Power supply for 2 x 12Vdc 7Ah batteries (Not EN54 certified) F0702

Cost effective 24 Vdc supply


3 months warranty

316 Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za Call us on 0860 22 55 23 or +27 (0) 11 574 2500 or Fax +27 (0) 11 574 2539 - Email: sales.za@adiglobal.com - Web: www.adiglobal.com/za 317
Next Section

ADI makes a difference!


ADI is also in the service business where above all people make the difference. We need
to be passionate about our work, our customers and service.
Smart security connections. Delivered. Because we care.

You might also like