Professional Documents
Culture Documents
The replacement of a defect MMC by a new one (with no data), must be done with an
operating SCOH.
The current NE-VCDB is being copied automatically to the new MMC.
The password data, license and subrack label are not automatically transformed to the MMC.
To adopt these data to the new MMC, they must be inserted via the LCT again.
If an SCOH is replaced, the old MMC (placed at the front panel of the SCOH) must be
adopted before the new SCOH is inserted. The MMC data belongs always to the subrack!
Passwords, license and subrack label are set to default after an SCOH reboot.
Also the NE-VCDB is being lost after a Power Off (pulling out the SCOH).
Note:
The SCOH contains a backup battery. See the ITMN manual how to activate and handle that
battery.
A42022-L5957-C455-03-7619 809
Graphical User Interface Manual (GUIMN) How To... (Exchanging Defective Modules)
SURPASS hiT 7070 3.4
If you replace a defective SCOH, you must follow the below flow chart.
Note:
The SCOH contains a backup battery. See the ITMN manual how to activate and handle that
battery.
810 A42022-L5957-C455-03-7619
How to... (Exchanging Defective Modules) Graphical User Interface Manual (GUIMN)
SURPASS hiT 7070 3.4
A42022-L5957-C455-03-7619 811
Graphical User Interface Manual (GUIMN) How To... (Exchanging Defective Modules)
SURPASS hiT 7070 3.4
812 A42022-L5957-C455-03-7619
How to... (Exchanging Defective Modules) Graphical User Interface Manual (GUIMN)
SURPASS hiT 7070 3.4
If you replace a defective SCOH inclusive a defective MMC, you must follow the below flow
chart.
Note:
The SCOH contains a backup battery. See the ITMN manual how to activate and handle that
battery.
A42022-L5957-C455-03-7619 813
Graphical User Interface Manual (GUIMN) How To... (Exchanging Defective Modules)
SURPASS hiT 7070 3.4
814 A42022-L5957-C455-03-7619
How to... (Exchanging Defective Modules) Graphical User Interface Manual (GUIMN)
SURPASS hiT 7070 3.4
A42022-L5957-C455-03-7619 815
Graphical User Interface Manual (GUIMN) How To... (Exchanging Defective Modules)
SURPASS hiT 7070 3.4
If you replace a defective MMC on a working SCOH, you must follow the below flow chart.
816 A42022-L5957-C455-03-7619
How to... (Exchanging Defective Modules) Graphical User Interface Manual (GUIMN)
SURPASS hiT 7070 3.4
A42022-L5957-C455-03-7619 817