You are on page 1of 24

TAS INDIA PVT.LTD.

Office No-03, Ground Floor, Building No.4A,SEZ,SPInfocity,Saswad Road,Phursungi,Pune-412308

To,
Mr. Ravi Yeole
Email: ravi@jains.com
Jain Irrigation
Jalgaon

Dear Sir,

Total Automation Solutions (TAS) is a Global Control & Automation and Solar PV based and Solar Agri
Pump set Monitoring, Solar roof top based Automation and Telemetry Solutions provider for Solar,
Wind and Thermal Substations in various verticals and actively working in Renewable Energy end to
end M2M cloud based Solutions.

TAS has presence globally serving customers in Oil & Gas, Energy, Utilities and Other Industrial
verticals.
TAS SOLUTIONS:
SOLAR AGRI PUMP SET MONITORING
SOLAR & WIND PLANT/SUBSTATION TELEMETRY SOLUTIONS
WIRELESS SOLUTION FOR STRING COMBINER BOX INVERTER ROOM MCM
SCADA SYSTEMS FOR LOCAL PLANT OPERATIONS
CENTRAL DASHBOARD FOR MULTIPLE PLANTS AT HEAD OFFICE
ACCESS ANYWHERE
WIRELESS ROOF TOP MONITORING SYSTEM
SINGLE WINDOW AUTOMATION SOLUTIONS FOR ENTIRE SOLAR PLANT & WIND
SUBSTATIONS.
Please find enclosed here with the Catalogue for more details.

We have installed these systems for various applications like Solar Plants and WTG Substations
Telemetry system and Oil and Gas applications.

Should you require any further details, please feel free to contact with us.

Thanking you and assuring you our best attention at all the times.

Kindly contact / forward us your requirement.

Vishal Khalotiya
RSM- Central Region
TAS India Pvt Ltd
Block 4A, SEZ, SP Infocity
Phursungi, PUNE 412308, India
(T) +91 20 26980089
(M) +91 9144419689
Email: vishal.khalotiya@tasind.com

TIPL INTRODUCTION LETTER & PTR-REV0


PAGE 1 OF 24
TAS INDIA PVT.LTD.
Office No-03, Ground Floor, Building No.4A,SEZ,SPInfocity,Saswad Road,Phursungi,Pune-412308

1 Introduction to TAS India Private Limited


TAS India Private Limited is the total automation solution provider for various sectors like
1. Power (Wind, Thermal, Solar)
2. M2M Solutions
3. Oil & Gas
4. Township Management Solutions
TAS is a ISO 9000 Certified Organization working as a automation & SCADA solutions specialist
company

TAS is a privately-held Total Quality (ISO9001) manufacturer of industrial automation, data-


acquisition, and control products designed for the harsh conditions found on Water , waste water,
water piping, Oil and Gas Offshore platforms, plant floors and other extreme environments. TAS
was established in 1975. For three decades, TAS has remained continuously profitable and well
financed. Innovative engineering and cutting-edge technology have long been TAS's hallmark. TAS's
distinctive product line reflects its bold vision of systems. Throughout its 30+ year history, TAS has
championed the cause of open connectivity and scalability for industrial automation products. This
open systems approach contrasted with the prevailing proprietary product strategies used by other
manufacturers to "lock-in" customers.
Today, the automation industry is realizing the advantages of open systems and TAS's long-standing
leadership in the innovation and promotion of open systems has yielded tremendous growth for TAS
and its partners. TAS's products are used in applications across a variety of diverse industries, and
are available through an international network of independent distributors and system integrators
We are pleased to bring it to your attention that TAS India Pvt. Ltd. has taken up EPC
contracts/projects and has executed as a single source covering all the above four categories.
TAS in an ISO 9001:2008 certified company & having HSE policy in place. In fact we are proud to
receive HSE award from Daleel Petroleum Oman, a second largest oil & gas company in Oman.

TIPL INTRODUCTION LETTER & PTR-REV0


PAGE 2 OF 24
TAS INDIA PVT.LTD.
Office No-03, Ground Floor, Building No.4A,SEZ,SPInfocity,Saswad Road,Phursungi,Pune-412308

2 Executive Summary
TAS INDIA PRIVATE LTD is a Total Quality (ISO9001) certified, global company having their head
office at Pune and it has been registered in various countries with following names.
Total Automation Solutions (TAS) in Oman,
Total Automation Solutions (TAS) USA in USA
Doha Total Automation Solutions (TAS) in Qatar.
TAS, is an automation specialist M2M gateway, Well Head M2M solution and SCADA Company. It
has undertaken number of significant projects across the globe. Some of these projects have been
awarded directly to TAS as Design, Engineering, Supply, Erection, Procurement Contract (EPC) and
other projects where TAS has been sub-contracted by the DCS companies.

I)Innovation and adaptability are the hallmarks of TAS and we aim at creating value for our
customers in an ever-changing market. The Company drives the nation's growth by being
responsible to its leadership position in running the "core" business sectors of the Indian Economy,
be it Infrastructure, Petrochemicals, Refining, Oil and Gas Exploration. Set up in 2006 with
manufacturing, design and engineering facilities in the industrial city of Pune (160 km southeast of
Mumbai),

Some of these projects are very large ones like 230 wells automation project of Daleel petroleum,
and 500 wells of ESSAR CBM project. Both these projects are of very large size and the scope
includes complete Design, Engineering, Supply, Erection, and Procurement Contract on EPC basis.
For more details please refer to the reference document attached here with.
TAS Offers their well head automation solutions based on TAS products.

II. Large pool of experienced engineers available in India


TAS has impressive work force of more 70 employees out of which 60 are involved in project
execution in both domestic and international markets. These people include experts in the field of
automation, electronics, communication systems and IT. The project team is well balanced group of
people who understand both the technology and its applications. This has been a key driver in
making TAS as adaptive and flexible to execute projects of varying magnitude and complexity.

III. Experience and proven track record of large project execution in India
The innovative and adaptability of TAS organization is truly proven in form of successful track record
of having executed large and very complex projects.
Here is a brief description of selected few projects undertaken by TAS which has elements of -
First time in world and in India
Strong Domain on CBM Application
Large size orders
Complicated and complex System Engineering with TAS M2M solution

TIPL INTRODUCTION LETTER & PTR-REV0


PAGE 3 OF 24
TAS INDIA PVT.LTD.
Office No-03, Ground Floor, Building No.4A,SEZ,SPInfocity,Saswad Road,Phursungi,Pune-412308

System Integration with other make M2M solution and Radio System
Required large number of skilled and experience manpower
Very aggressive schedule
Directly linked with financial performance of the customer giving returns on investments
etc.

IV) Knowledge: We enhance customers global competitiveness, Platform Independent Solutions


based on Customer Requirements, End to End Solutions in C & A Domain, Third Party System
Interface Modbus, IEC101/104, 61850, DNP3Execution and Support with Remote Engineering office,
Expertise in Wireless Communication and Enterprise IT Integration, RF, Wireless HART, Cellular,
Satellite SAP, Seamless System Migration
V) Activities :Control System EngineeringInputs to Vendor, Control System EngineeringReview
and Approval of Design documents, Plant C&I EngineeringTelecommunicationOil and Gas Well
Head M2M solution, Telemetry system using M2M and Cloud based solution for state level dispatch
center(SLDC), communication: Radio communication Systems, Plant Integrations and dash board
information through Internet, GSM, GPRS network, Oil and Gas Pipelines communication Network
through FOC, Radio network, Energy Monitoring through GSM, GPRS Network, Oil Tanking, storage
and transportation, GPS tracking, Water SCADA Remote plant control and monitoring, Gas
distribution Station control and monitoring, LPG storage, transportation and distribution RFID
Tracking and traceability.

Platform DomainTAS Scalable Control System, TAS well head Monitoring and Control M2M
SOLUTION, TAS Radio Communication, TAS Networking Solutions

TIPL INTRODUCTION LETTER & PTR-REV0


PAGE 4 OF 24
TAS INDIA PVT.LTD.
Office No-03, Ground Floor, Building No.4A,SEZ,SPInfocity,Saswad Road,Phursungi,Pune-412308

3. TASM2M Telemetry Solution

Description:

Typical Solar Power Plant consists of MFM meter/PLC/SCADA for HT Control panels. These
MFM Meters will be interfaced with TASM2M Remote Gateway through RS485 or any
standard communication protocol.

The data captured by M2M gateway from SOLAR POWER PLANT will be sent to TAS M2M
Master gateway through Internet(VSAT/GPRS/Lease Line) at the SLDC site through
TASM2M Cloud management.

The proposed M2M Master gateway will communicate with SCADA via IEC60870-5-
101/104 protocols and report the desired Solar PV Plant Data to SCADA.

As per CERC Guidelines data update rate of 30 sec is required which we comply through
fast update of M2M gateway and TASM2M Cloud management.

As per the SLDC following parameters will be made available using the Proposed TAS M2M
Telemetry System:

a) Active Power(Grid )

b) Reactive Power(Grid)

c) Bus Voltage(Grid)

TIPL INTRODUCTION LETTER & PTR-REV0


PAGE 5 OF 24
TAS INDIA PVT.LTD.
Office No-03, Ground Floor, Building No.4A,SEZ,SPInfocity,Saswad Road,Phursungi,Pune-412308

d) Frequency(Grid)

e) Current(Grid)

f) Circuit Breaker Status(HT Panel).

g) Isolator Status

Data Representation in SLDC SCADA over IEC-101/104 Protocol:

TIPL INTRODUCTION LETTER & PTR-REV0


PAGE 6 OF 24
TAS INDIA PVT.LTD.
Office No-03, Ground Floor, Building No.4A,SEZ,SPInfocity,Saswad Road,Phursungi,Pune-412308

4. PROVEN TRACK RECORD FOR SOLAR PLANTS


Suzlon Energy Limited

SYSTEM ARCHITECTURE FOR TELEMETRY/M2M SOLUTION

Description for Telemetry (M2M) solution proposed

There is One Feeder (25MW) at Urvakonda and two Feeders (20MW & 19.9MW) at Guntakal
Substations.
The MFM/ABT meters in each Feeder of Urvakonda is connected to TAS M2M remote Gateway via
RS-485 MODBUS. The TAS M2M Remote Gateway is then interfaced with the PLCC PUNCOM Make
PL-9500 (Ver 01) via RS-422 Communication.
The data Pack of the Feeders at Urvakonda Substation is transmitted to Guntakal Substation via PLCC
network.
Similarly A remote TAS M2M gateway shall be connected to MFM/ABT Meters of two Feeders of
Guntakal Substation and shall be interfaced with the Guntakal PLCC.
From Guntakal Substation Data Packs of Urvakonda substation and Guntakal Substations together
will be sent to Gooty RS using PLCC Network where Via FOC panel all the substation data will be sent
to Gooty SS.
M/s Suzlon shall provide the PLCC Panel/FOC Panel communication protocol details for effective
communication to be established

The proposed M2M gateway will communicate with ALDC/SLDC SCADA via & IEC104 protocols and
report these meter data to SCADA. The expected update rate of 10 seconds will be achieved through
fast update of M2M Gateway. The SCADA configuration for these two meters can be done into
SCADA so that the real time meter data can be monitored and shown as trend, history, alarm (if
configured) and shall be exported to custom reports for further analysis/billing.

TIPL INTRODUCTION LETTER & PTR-REV0


PAGE 7 OF 24
TAS INDIA PVT.LTD.
Office No-03, Ground Floor, Building No.4A,SEZ,SPInfocity,Saswad Road,Phursungi,Pune-412308

SolaireDirect, Pune

Total 5 nos of orders are received and under execution.

M2M Solution @ 5 MW Solar PV Power Plant for SolaireDirect

Refer below System Architecture

Description for M2M solution proposed for 10MW for SolairDirect

There are 4 Nos L&T Make Meters at BAP substation with following specifications.
Electronic Trivector Meter ER300P, WR300BB51ABTRR,
3P4W,3x63.5V,-/5A Io,50 Hz,0.2s Class for Active & 0.5 Class for Reactive , 10imp/Wh & Varh.
There four meters will be interfaced with TAS M2M Remote gateway through RS485. The data
captured by M2M gateway will be send to data cloud.
The cloud data will be sent to TAS M2M Master gateway at the SLDC Heerapura Jaipursite of
RRPNNL. The proposed M2M gateway will communicate with Alstom SCADA via IEC101 & IEC104
protocols and report these meter data to SCADA. The expected update rate of 10 seconds will be
achieved through fast update of M2M Gateway. The SCADA configuration for these four meters can
be done into Alstom SCADA so that the real time meter data can be monitored and shown as trend,
history, alarm (if configured) and shall be exported to custom reports for further analysis/billing.

TIPL INTRODUCTION LETTER & PTR-REV0


PAGE 8 OF 24
TAS INDIA PVT.LTD.
Office No-03, Ground Floor, Building No.4A,SEZ,SPInfocity,Saswad Road,Phursungi,Pune-412308

M2M Solution @ 10 MW Solar PV Power Plant for LEPL Projects Ltd

Refer below System Architecture

Description for M2M solution proposed for 10 MW for LEPL Projects Ltd

There are 2 Nos Secure Make Meters atLEPLsubstationwith following specifications


ABT Type Meter, Apex Meter (half 19 rack) 0.2s Class for Active & Reactive power.
There two meters will be interfaced with TAS M2M Remote gateway through RS485. The data
captured by M2M gateway will be send to data cloud. The cloud data will be sent to TAS M2M
Master gateway at the SLDC Heerapura Jaipursite of RRPNNL. The proposed M2M gateway will
communicate with Alstom SCADA via IEC101 & IEC104 protocols and report these meter data to
SCADA. The expected update rate of 10 seconds will be achieved through fast update of M2M
Gateway. The SCADA configuration for these two meters can be done into Alstom SCADA so that the
real time meter data can be monitored and shown as trend, history, alarm (if configured) and shall
be exported to custom reports for further analysis/billing.

TIPL INTRODUCTION LETTER & PTR-REV0


PAGE 9 OF 24
TAS INDIA PVT.LTD.
Office No-03, Ground Floor, Building No.4A,SEZ,SPInfocity,Saswad Road,Phursungi,Pune-412308

Fortum India

M2M Solution @ 5MW Solar PV Power Plant for Fortum India

Refer below System Architecture

Description for Telemetry (M2M) solution proposed

There is 1 No ABT MeteratBilwara substation. Fortum had provided ABT meter Modbus data
information from ABT meter supplier to connect our M2M device.
Thesetwo meters will be interfaced with TAS M2M Remote gateway through RS485. The data
captured by M2M gateway will be send to data cloud.

The cloud data will be sent to TAS M2M Master gateway at the SLDC site of RRPNNL. The proposed
M2M gateway will communicate with SCADA via IEC101 & IEC104 protocols and report these meter
data to SCADA. The expected update rate of 10 seconds will be achieved through fast update of
M2M Gateway. The SCADA configuration for these two meters can be done into SCADA so that the
real time meter data can be monitored and shown as trend, history, alarm (if configured) and shall
be exported to custom reports for further analysis/billing.

TIPL INTRODUCTION LETTER & PTR-REV0


PAGE 10 OF 24
TAS INDIA PVT.LTD.
Office No-03, Ground Floor, Building No.4A,SEZ,SPInfocity,Saswad Road,Phursungi,Pune-412308

Juwi India renewable Energies Pvt. Ltd.

System Architecture for Lease Line Based Telemetry Solution

Description for Telemetry (M2M) solution proposed

We assume that there is ABT Meters/MFM/PLC at Solar Power Plant


CLient shall provide ABT meter/MFM/PLC Modbus data information from ABT meter/MFM/PLC
supplier to connect our M2M device.
These ABT Meters/MFM Meters will be interfaced with TASM2M Remote Gateway through RS485.

The data captured by M2M gateway from SOLAR POWER PLANT will be sent to TAS M2M Master
gateway at the SLDC Jabalpur/Indore site through Lease Line. The proposed M2M Master gateway
will communicate with SCADA via IEC60870-5-101/104 protocols and report the desired Solar PV
Plant Data to SCADA. The expected update rate will be achieved through fast update of M2M
gateway. The SCADA configuration for the meters can be done into SCADA so that the real time
meter data can be monitored and shown as trend, history, alarm (if configured) and shall be
exported to custom reports for further analysis/billing.

TIPL INTRODUCTION LETTER & PTR-REV0


PAGE 11 OF 24
TAS INDIA PVT.LTD.
Office No-03, Ground Floor, Building No.4A,SEZ,SPInfocity,Saswad Road,Phursungi,Pune-412308

Rays Power Infra:

Total 6 Nos. of Orders for Wireless Solution for SCB, MCR & SCADA

Scada for Developing SAS for 10MW Solar PV Plant @ Haidiram Solar Plant.

Scada for Developing SAS for 10.4MW Solar PV Plant @ Medak Solar Plant

Scada for Developing SAS for 10MW Solar PV Plant @ Nreeus Solar Plant.

Scada for Developing SAS for 10MW Solar PV Plant @ Pragathi Solar Plant.

Scada for Developing SAS for 10MW Solar PV Plant @ Rays Solar Plant.

Scada for Developing SAS for 1MW Solar PV Plant @ Ridhu Solar Plant.

TYPICAL SYSTEM ARCHITECTURE

Description:
1. This is a typical System Architecture for Wireless SCB Monitoring and SCADA Solution. The
above architecture shown is considered for the Wireless SCB connectivity for one Inverter
room on the basis of per MW solar farm installation
2. Per MW 10 to 16 Nos. SCBs are considered as per the technical detailing by M/s Rays Power.
3. Total 1 No. of Inverter room is considered for per MW solar farm installation.
4. An OFC Connectivity between all Inverter rooms and Control Room is assumed as per the
Technical specifications received from M/s Rays Power.
5. Based on the technical information from M/s Rays Power the bill of material is finalized as
per the Inverter type, and SCADA BOM is as per the no. of control rooms:

TIPL INTRODUCTION LETTER & PTR-REV0


PAGE 12 OF 24
TAS INDIA PVT.LTD.
Office No-03, Ground Floor, Building No.4A,SEZ,SPInfocity,Saswad Road,Phursungi,Pune-412308

OPJ GROUP

Re-Development work of the SCADA System for BAP and Tinwari 5MW
Solar PV Plant.

Refer below System Architecture

Scope of Work:
1. Whole SCADA re-development with up gradation of the SCADA screens and re
modification of the existing SCADA monitoring Graphics according to the requirement of
the customer with Open options for the future integration and modification.
2. Establishing Communication with the existing Hardware system which includes all the Six
PLCs routed via OFC to the SCADA control room.
3. Dedicated Engineers will be provided for the onsite and offsite Development of SCADA.

TIPL INTRODUCTION LETTER & PTR-REV0


PAGE 13 OF 24
TAS INDIA PVT.LTD.
Office No-03, Ground Floor, Building No.4A,SEZ,SPInfocity,Saswad Road,Phursungi,Pune-412308

Amanora Facility Management System

Introduction

Total Automation Solution offers automation, SCADA and instrumentation engineered systems
solutions to the areas like oil and gas industry, Building Management System. This includes from
concept design to commissioning and start up on turnkey basis. Here TAS is giving solution for
Building Management System to Amanora Park Town Pune.
Amanora Park Town is privately managed residential Township managed by City Corporation
Limited. It is developed in 400 acre in Hadapsar Pune. This is Indias first digital township.

Scope of Project

This Amanora Park Town Residential Township is having prepaid metering system for the utilities like
Energy, Gas and water.They awarded the contract for supply, implementation, integration and
maintenance of Scada Software/System.

Solution

TAS has supplied Remote Telemetry System for gathering field data by using M2M solution, Data
Master and ZenonSCADA system. The Prime Function of the system is to provide safe and efficient
operation of following areas.
TAS has integrated following areas.
Electrical substation Main Substation (22KV/11KV) and Sector wise substations
Prepaid Energy Meters
Prepaid Gas Meters
Sector wise Water Meters
Elevators
Fire Fighting System

For collecting data of substation TAS has provided M2M solution panels. Ipm2m M2M solution was
chosen for data gathering. Total eleven M2M solution panels are supplied for substation and for
water metering system. Other small panels are Data Master panels those are supplied for Prepaid
Metering System like Energy, Gas etc. All the data is gathered to data center over fiber and
connected to scada system. MS Windows based 32 bit Zenon SCADA was chosen for monitoring and

TIPL INTRODUCTION LETTER & PTR-REV0


PAGE 14 OF 24
TAS INDIA PVT.LTD.
Office No-03, Ground Floor, Building No.4A,SEZ,SPInfocity,Saswad Road,Phursungi,Pune-412308

controlling the system. Zenon SCADA handles unlimited tags for large amount of data with history,
alarms, special reports generation.

TAS has given web server client connectivity to respective departments in Amanora. On Web client
operator can monitor the real time as well as historical data.

System Architecture

Resulting Benefits
Automates data collection and deposits into a SCADA data base for historical uses.
Retrieves event reports from database and it can be used for immediate after-action
analysis.
Alert to citizens by sending sms on low balance regarding utility meters.
Revenue generation can be done by using reports.
Flexible In Connections for Serial, Ethernet, USB, etc.
Wide-range of supported protocols available-Modbus, IEC104,CAN.
OEM-specific configurations (available upon request).
Client Dashboards
Personalized client data presentation
View data on web browser device (PC, laptop.)
Secure username/password access
View historical/trending/real-time data
Alerts & alarms via text message or email

TIPL INTRODUCTION LETTER & PTR-REV0


PAGE 15 OF 24
TAS INDIA PVT.LTD.
Office No-03, Ground Floor, Building No.4A,SEZ,SPInfocity,Saswad Road,Phursungi,Pune-412308

PROVEN TRACK RECORD FOR OIL AND GAS


Raniganj CBM development Project

Introduction
Thecomplete scope of detail, design, engineering, supply of M2M solution based control system,
SCADA, Factory Acceptance Testing, shipments to site, installation, site acceptance testing,
commissioning and warranty support as per tender requirement and without any deviation for
technical requirements or scope of supply and services.
Solutions:
1. TASM2M Scalable M2M solution based control system from USA.
2. FreeWave Radio Solutions from USA

Selected TASM2MM2M solution for well site is an optimized solution to meet complete
requirements of well site. It has also got on board IO so that in case customer wants to connect
some hardwired IO like temp alarm, any pressure transmitter inputs etc without any addition of IO
modules. It has strong features like Data logging, Exception Reporting and on board communication
ports and more.
TASM2M Redundant M2M solution for GCS, MCS and Metrix locations is high end M2M solution
with redundant Ethernet communication ports to communicate on redundant communication
network between GCS, MCS and Metrix on Fiber optic.
Executed system is complete in all respect and it is scalable for more than 500 wells, 9 GCS stations
and more number of customer stations.
The offered system is rugged and well proven for oil and gas field requirements. This system is well
proven and being used by many customers across the globe one such customer in Australia is Add
Energy for their CBM fields.

Radio based solution for data collection from wells and sending to nearest GCS station. Since the
distance is between 500 meters to 3km with clear line of site, this is the best solution as customer
will not be dependent on network availability of mobile service provider and also almost no running
cost. Customer will own the assets and there is risk of increasing the running cost as against the
mobile services cost. This has significant advantages against mobile service network.

TIPL INTRODUCTION LETTER & PTR-REV0


PAGE 16 OF 24
TAS INDIA PVT.LTD.
Office No-03, Ground Floor, Building No.4A,SEZ,SPInfocity,Saswad Road,Phursungi,Pune-412308

SCADA Architecture

M2M SOLUTION Architecture

Well Automation Applications


System Integration
Water level monitoring

TIPL INTRODUCTION LETTER & PTR-REV0


PAGE 17 OF 24
TAS INDIA PVT.LTD.
Office No-03, Ground Floor, Building No.4A,SEZ,SPInfocity,Saswad Road,Phursungi,Pune-412308

Gas metering solutions


SCADA Engineering
Remote Well Monitoring
Asset Management Geographical Navigation for Re- mote Well Monitoring & Control:
Navigation for Remote Well Monitoring & Control:
Well Pulse automation system allows operators to monitor well sites and make changes remotely,
enabling each operator to manage more and more number of wells than before the system was
put into place and helping customer bring online more and more wells as more and more wells get
drilled every year. This results more efficiently utilizing its existing operator staff.
Integration of Gas Meters with Well Pulse CBM Well Head monitoring Solution:
Water production information is important for reporting purposes to the Customer for
Environmental Quality. Produced Water Metering for accountability with
integrated monitoring using turbine meters. The output is terminated at the local M2M solution
and totalized, and the data are logged by the M2M solution.
The calculated water level can then be used for control purposes by the local remote terminal unit
(M2M solution).
Each of the well operators was to remotely access, monitor, collect, and even make operational
changes in their own wellhead locations.
Water level, pump loading, water and gas production rates are the fundamentals of optimization
Level control is done simply by switching the pump on and off, but in most cases, a variable
frequency drive (VFD) is used. The local, on-site instrumentation needs to be capable of
implementing an actual level algorithm that provides set point control as predetermined by the
operator or production engineer
SCADA Solutions: Gas Flow Rate, Gas Temperature, Gas Differential Pressure, Separator Pressure,
Water Flow Rate, Annulus Pressure, VFD Motor Current, VFD Motor Torque, Water Flow Totalizer,
Gas Flow Totalizer
Well SCADA system features state-of the art monitoring, control, and diagnostic functionality that
optimizes green energy generation operations. .
E-capabilities of M2M solution and their ability to communicate through serial and Ethernet
communications to sensors, (including pressure and multivariable devices) and to provide the logic
by which you ultimately control the well.
Wireless Solutions: We offer FreeWave industrial grade Radio system from USA. Smooth
Integration with Control & Monitoring Systems, Highly Reliable & Scalable option for
Communication, Usable in Harsh Environmental Conditions, Giving great flexibility & quick
deployment, Simultaneous Monitoring & Control, Options also available for Hybrid networks to
over- come terrain challenges
Secure and infinitely configurable network ensures an adaptive, flexible approach to wireless.
Smart Wireless strategy ensures the greatest network integrity by allowing devices to

TIPL INTRODUCTION LETTER & PTR-REV0


PAGE 18 OF 24
TAS INDIA PVT.LTD.
Office No-03, Ground Floor, Building No.4A,SEZ,SPInfocity,Saswad Road,Phursungi,Pune-412308

communicate with each other with no single point of failure


Well Pulse CBM Well Head Solution have truly accomplished the task of having a M2M SOLUTION,
EFM and Wireless System in the same device. This combination allows a huge cost savings for the
producer on the front of the project and even greater savings long term through reduced
maintenance and field visits.

Benefits of a Well Pulse M2M Solution


Environmental ratings of the controller are similar to those of an M2M SOLUTION
Ability to remotely load new gas calculations as required by governing bodies
Shared database so the AGA inputs and results can be used in the control strategy
Open architecture protocols such as Modbus, Modbus TCP, IEC104/101 and DNP3.
Ability to display measurement and process control data locally.
High Speed data logging of process data allowing the reservoir engineers to see well
dynamics with as frequent as one second resolution.

TIPL INTRODUCTION LETTER & PTR-REV0


PAGE 19 OF 24
TAS INDIA PVT.LTD.
Office No-03, Ground Floor, Building No.4A,SEZ,SPInfocity,Saswad Road,Phursungi,Pune-412308

Daleel Well Head Automation

Introduction

Total Automation Solution offers automation, SCADA and instrumentation engineered systems
solutions to the oil and gas industry, from concept design to commissioning and start up on turnkey
basis
Daleel Petroleum LLC isa multi-million $ company in Oman who operates oil and gas field in north
Oman. They have more than 500 oil and gas wells. Daleel is collaborated with CNPC China and are in
this business for more than 30 years.

Scope of Project

Daleel has more than 500 oil and gas wells in this field and they were looking for automation of
these wells. They awarded the contract for 150 wells on EPC basis to Total Automation Solutions
(TAS) in phased manner. The project scope included complete design, engineering, supply, factory
acceptance testing, site installation and commissioning of field instruments, M2M solution and
SCADA system.
.

Solution

TAS has supplied state of the art wireless HART solution for field data gathering, M2M solution and
ICONICS SCADA system. The Prime Function of the system is to provide safe and efficient operation
of oil and gas wells. Data gathering from field, Beam pump and ESP, historisation and reports
generation.

Complete project is divided in to two phases. TAS has supplied state of the art wireless transmitters
with HART functionality. Ipm2m was chosen for data gathering. MS Windows based 64 bit ICONICS
SCADA was chosen for monitoring. ICONICS SCADA handles large amount of data with special
reports generation, Earthworks package for geographical location identification as 150 wells are
spread out on a large oil field.

TAS has also connected their oil field with their head office Muscat on VPN connectivity to monitor
real time data from oil fields centrally from head office.

TIPL INTRODUCTION LETTER & PTR-REV0


PAGE 20 OF 24
TAS INDIA PVT.LTD.
Office No-03, Ground Floor, Building No.4A,SEZ,SPInfocity,Saswad Road,Phursungi,Pune-412308

System Architecture

Resulting Benefits

Automation and remote monitoring of Daleel oil field for well performance monitoring, historisation
and complete analysis of well and equipment performance.

Head office has real time station monitoring and real time dash board information. They are able to
remotely monitor the real time performance of their wells and equipment.

TIPL INTRODUCTION LETTER & PTR-REV0


PAGE 21 OF 24
TAS INDIA PVT.LTD.
Office No-03, Ground Floor, Building No.4A,SEZ,SPInfocity,Saswad Road,Phursungi,Pune-412308

Adani Gas Application

Introduction
Total Automation Solution offers automation, SCADA and instrumentationengineered systems
solutions to the oil and gas industry, from concept design tocommissioning and start up.

Adani Energy Ltd is one of the companies among the Adani Group focusing onnatural gas
distribution channel in conjunction with Gujarat State Petronet Ltd(GSPL). Adani Energy has a chain
of stations, retailing station called as City GateStation and has intent to expand the reach beyond
Gujarat.Adani Energy Ltd Possessesthe largest chain of CNG stations in Ahmedabad

Scope of Project
The Prime Function of the system is to provide safe and efficient operation of CNGstations and
uninterrupted gas supply to industrial customers with minimum loss ofunaccounted natural gas and
safe and efficient operation of CNG stations. Integrate allthe gas stations to head office for remote
monitoring and dash board information.

Monitor the inventory and price control from one single place that is head office.Operation of
Ahmedabad city gas distribution network is being distributed amongfollowing major categories
1. Industrial metering system
2. City gate station
3. Medium industries and commercial metering system
4. CNG stations

Solution
Since the customer wanted to develop custom made applications, and AGAcalculation for gas
metering, we selected the VT-UIPM-135D, which has 32MB ofDynamic RAM and 64MB of flash
memory to run several applications includingAGA calculations. And these can be run concurrently. In
addition, the unit offersvarious interface capabilities, such as Ethernet, RS-232 and RS-485.14 Nos of
VT-UIPM-135D are provided at Daughter/Booster CNG Stations. All
dispensers are connected to the VT-UIPM-135D on Modbus protocol. All otherdispensers not
supporting the Modbus are interfaced using the mass flow meters to theVT-UIPM-135D Each
daughter/Booster stations are connected to the central SCADAServer through VSAT Link. SCADA
Servers are directly communicating with the M2M solution. VSAT Antennas are provided at each
Booster/Daughter Stations

TIPL INTRODUCTION LETTER & PTR-REV0


PAGE 22 OF 24
TAS INDIA PVT.LTD.
Office No-03, Ground Floor, Building No.4A,SEZ,SPInfocity,Saswad Road,Phursungi,Pune-412308

System Architecture

Resulting Benefits
The performance of the new unit exceeds by far the old unit. The new unit has battery
life of 10 years & battery backup of 15 days with solar power supply. The new units
were designed and developed to withstand the hazardous environments and are able to
run reliably under very rough ambient conditions.
Head office has real time station monitoring and real time dash board information.
They are able to change the gas price in real time and at a single stroke, across city
from head office.

TIPL INTRODUCTION LETTER & PTR-REV0


PAGE 23 OF 24
TAS INDIA PVT.LTD.
Office No-03, Ground Floor, Building No.4A,SEZ,SPInfocity,Saswad Road,Phursungi,Pune-412308

OUR DELIGHTED CUSTOMERS

TIPL INTRODUCTION LETTER & PTR-REV0


PAGE 24 OF 24