00
1 0.25 47.00
2 0.50 82.00
3 0.75 117.00
4 1.00 152.00
5 1.25 187.00
6 1.50 222.00
7 1.75 257.00
8 2.00 292.00
9 2.25
10 2.50
11 2.75
12 3.00
13 3.25
14 3.50
15 3.75
16 4.00
17 4.25
18 4.50
19 4.75
20 5.00
21 5.25
22 5.50
23 5.75
24 6.00
25 6.25
26 6.50
27 6.75
28 7.00
29 7.25
30 7.50
31 7.75
32 8.00
33 8.25
34 8.50
DISEO ESTRUCTURAL TANQUE SEPTICO
PROYECTO:
1.- GEOMETRIA
5.5 3.0
5.5 3.0
3.0 2.0
Planta Corte
PRESIONES
PROFUND. S/C SUELO TOTAL
Mt. Ton/m2 Ton/m2 Ton/m2
0.00 0.31 0.00 0.31
0.25 0.31 0.15 0.46
0.50 0.31 0.31 0.61
0.75 0.31 0.46 0.77
1.00 0.31 0.61 0.92
1.25 0.31 0.77 1.08
1.50 0.31 0.92 1.23
1.75 0.31 1.08 1.38
2.00 0.31 1.23 1.54
3.- ANALISIS
El anlisis estructural se ha realizado utilizando elementos finitos, para lo cual se ha utilizado el programa de computo
sap90 utilizando el elemento SHELL, sometido a presin de tierra
Se ha considerado el siguiente modelo estructural:
Y
Z
5.5 3.0
5.5 3.0
3.0 2.0
X X
Muro M1
Planta Corte
3.1 .- MURO M1 SOMETIDO A EMPUJE ACTIVO DEL SUELO
RESULTADOS DEL PROGRAMA SAP
ELEMEN T ID 11 - ------------
JOINT M11 M22
11 5.14E-02 3.43E-01
12 5.14E-02 3.43E-01
46 1.42E-02 9.61E-02
47 1.43E-02 9.63E-02
ELEMEN T ID 45 - ------------
46 1.42E-02 9.61E-02
47 1.43E-02 9.63E-02
81 -1.02E-02 -6.34E-02
82 -9.95E-03 -6.33E-02
ELEMEN T ID 79 - ------------
81 -1.02E-02 -6.34E-02
82 -9.95E-03 -6.33E-02
116 -2.31E-02 -1.45E-01
117 -2.27E-02 -1.45E-01
ELEMEN T ID 113 - ------------
116 -2.31E-02 -1.45E-01
117 -2.27E-02 -1.45E-01
151 -2.55E-02 -1.60E-01
152 -2.50E-02 -1.60E-01
ELEMEN T ID 147 - ------------
151 -2.55E-02 -1.60E-01
152 -2.50E-02 -1.60E-01
186 -1.87E-02 -1.16E-01
187 -1.83E-02 -1.16E-01
ELEMEN T ID 181 - ------------
186 -1.87E-02 -1.16E-01
187 -1.83E-02 -1.16E-01
221 -4.35E-03 -2.42E-02
222 -4.07E-03 -2.41E-02
ELEMEN T ID 215 - ------------
221 -4.36E-03 -2.42E-02
222 -4.08E-03 -2.41E-02
256 1.58E-02 1.07E-01
257 1.59E-02 1.07E-01
ELEMEN T ID 249 - ------------
256 1.58E-02 1.07E-01
257 1.59E-02 1.07E-01
291 4.00E-02 2.67E-01
292 4.01E-02 2.67E-01
0.400
0.300
M OM ENTOS (Ton-m )
0.200
M11
0.100
M22
0.000
0.00 0.50 1.00 1.50 2.00
-0.100
-0.200
ALTURA (m )
REFUERZO HORIZONTAL
Mmax= 0.21 Ton-m. (Nudo 175)
Mu= 0.31 Ton-m.
W= 0.011
REFUERZO VERTICAL
Mmax= 0.34 Ton-m.
Mu= 0.51 Ton-m.
W= 0.019