Assumption:-
Radiant flux = 68100kJ/hr.m2
Duty:-
Enthalpy = 746.67 kJ/kg at 280 C, 998.71 kJ/kg at 350 C
Duty=7793.10822(998.71-746.67)
= 1964174.996 kJ/ hr
Net Heat Release:-
qn=1964174.996/0.75 =2.62 106 kJ/ hr
Flue Gas with 25% excess air:-
= (3.02 106 kJ/ hr) (1010 lb/MM Btu)
=0.38kg/s
Approximate Radiant Duty:-
q
r =1964174.9960.7=1374922.497 kJ/ hr
=23.37m2
Now, we move towards the Dimensions of Furnace for which the configuration of tubes
is
Length=L = 6.1 m
23
3
L H W
Beam length = = 2.02m
Spacing Ratio=C-C/O.D
=5.33
From Fig 19.11 Kern
= 0.47
Cold Plate Area
Shield tubes, Acp=46.10.203=4.9532m2
Acp=4.9532+0.47(24.766)
=16.59m2
Envelope Area
=2(2.032.233)+2(6.1(2.03+2.233))
=61.07m2
Radiant section Area
AR=61.07-16.59
=44.48m2
AR/ Acp =2.68
Furnace Volume
=6.12.032.233=27.65m3
Mean Beam Length,L
2 3
L H W
= 3
=2.02 m
The value of (Pco2 + PH2O) = 0.23 atm
(Pco2 + PH2O)L = 0.232.02 =0.4637 atm.m
Since there is no Preheated air or fuel, the heat rate of
combustion air, qn,
equals the heat rate of fuel equals the zero. Assume the heat
loss from tubes,
Emissivity=0.39
Exchange Factor, F=0.69
AcpF=11.45 m2
qn/AcpF= 228820.96kJ/m2.hr
For this type of furnace assume that exit gas temperature is the
same as average fire box temperature 565.6C
tg2=tg= 565.6C
= 167039.3kJ/m2.hr
qn/AcpF=232269.5 kJ/m2.hr
For this type of furnace assume that exit gas temperature is the
same as average fir box temperature 787.8C
tg2=tg= 787.7C
HEAT DUTY
NUMBER OF TUBE REQUIRED
CONVECTION SECTION AREA
In convective section rest of the heat duty will be obtained.
QS
Qn
1-0.02-0.75
=0.23
Temperature differences
LMTD=362.71 C
= 361.375C
=0.9135m
=0.7615m
=4.65m2
=0.08 kg/m2.s
Where
a=2.461-0.759Z+1.625Z2
b=0.7675+21.3732-9.6625Z2
c=9.7938-30.809Z+14.333Z2
QC
AC
U C LMTD
Surface required for the convective heat transfer =
=352174.996/1
6.49362.71=58.88 m 2
=82 tubes