Viking Installation Guide

Viking Range Corporation

111 Front Street

Greenwood, Mississippi 38930 USA

(662) 455-1200

For product information,

call 1-888-VIKING1 (845-4641)

or visit the Viking Web site at

vikingrange.com

UL C UL Professional Hoods
F20470G EN (033111)
Table of Contents IMPORTANTPlease Read and Follow!
NOTE: If installing hood with warming shelf panel,
Warnings & Important Information________________________________________________________ 3-4
VWH 10H. Wall Hoods w/Standard Ventilator 24, 30, & 36
install warming shelf panel first. WARNING
Dimensions & Specifications _____________________________________________________ 5 IMPORTANT PLEASE READ AND FOLLOW To reduce the risk of fire, electric shock, or injury
Clearance Dimensions ___________________________________________________________ 6 to persons, observe the following:
Before beginning, please read these instructions
Interior Ventilator Dimensions ____________________________________________________ 7 completely and carefully. Use this unit only in the manner intended by the
VWH 18H. 24/27 Deep Wall Hoods 24, 30, 36, 42, 48, 54, 60, & 66 Do not remove permanently affixed labels, warnings, or manufacturer. If you have any questions, contact
Dimensions & Specifications ______________________________________________________ 8 plates from the product. This may void the warranty. the manufacturer.
Please observe all local and national codes and Before servicing or cleaning unit, switch power off
Clearance Dimensions _____________________________________________________________ 9
ordinances. If no local codes are applicable, wire in at service panel and lock service panel to prevent
Interior Ventilator Dimensions _____________________________________________________ 10 power from being switched on accidentally. When
accordance with the National Electrical Code,
Exterior Ventilator Dimensions ___________________________________________________ 11 the service disconnecting means cannot be locked,
ANSI/NFPA 70-latest edition.
VWH 18H. T-Series Wall Hoods 36, 48, & 60 Damp environment approved models should be installed securely fasten a prominent warning device, such
Dimensions & Specifications _____________________________________________________ 12 in a covered non-enclosed area and should be protected as a tag, to the service panel.
Clearance Dimensions __________________________________________________________ 13 from the elements as much as possible.
VCWH Chimney Wall Hoods 30, 36, 42, 48, 54, 60, & 66 The installer should leave these instructions with the
Dimensions & Specifications _____________________________________________________ 14 consumer who should retain for local inspectors use and WARNING
Clearance Dimensions __________________________________________________________ 15 for future reference.
TO REDUCE THE RISK OF FIRE, ELECTRICAL
Interior Ventilator Dimensions ___________________________________________________ 16 Check with a qualified and trained installer or local codes SHOCK, OR INJURY TO PERSONS, OBSERVE
Exterior Ventilator Dimensions ___________________________________________________ 17 for makeup air requirement, if any. THE FOLLOWING:
VIH Island Hoods 36, 42, 54, & 66 1. Installation work and electrical wiring must be
This hood is for residential installation only and is not done by qualified person(s) in accordance with
Dimensions & Specifications _____________________________________________________ 18
designed for installation over a commercial product. Make all applicable codes and standards, including
Clearance Dimensions ___________________________________________________________ 19 fire-rated construction.
sure power is off at the main circuit breaker or fuse box
Interior Ventilator Dimensions ___________________________________________________ 20 before making connections. To avoid risk of fire, electric 2. Sufficient air is needed for proper combustion
Exterior Ventilator Dimensions ___________________________________________________ 21 shock, or injury to persons, turn off the electricity to the and exhausting of gases through the flute
VCIH Chimney Island Hoods 36, 42, 54, & 66 (chimney) of fuel burning equipment to prevent
hood from the power supply before servicing or cleaning.
Dimensions & Specifications _____________________________________________________ 22 back drafting. Follow the heating equipment
Viking hoods are equipped with variable speed control
manufacturers guideline and safety standards
Clearance Dimensions ___________________________________________________________ 23 blowers. These units will not function with a single speed such as those published by the National Fire
Interior Ventilator Dimensions ___________________________________________________ 24 ventilator. All Viking Range ventilator kits are designed Protection Association (NFPA), and the
Exterior Ventilator Dimensions ___________________________________________________ 25 specifically for use with Viking Range hoods. Use of any American Society for Heating, Refrigeration and
VBCV Wall Custom Ventilator System non-Viking Range ventilator kit will void the hood warranty. Air Conditioning Engineers (ASHRAE), and the
Dimensions & Specifications _____________________________________________________ 26 local code authorities.
Viking hoods are equipped with the variable speed 3. When cutting of drilling into wall or ceiling, do
Installing Hood Canopy _________________________________________________________ 27 not damage electrical wiring and other hidden
controls for blowers. These units will not function with a
Clearance Dimensions ___________________________________________________________ 28 utilities.
single speed ventilator. All Viking ventilator kits are
VBCV Ventilator Dimensions _____________________________________________________ 29 designed specifically for use with Viking hoods. Use of any
4. Ducted fans must always be vented to the outdoors.
VICV Island Custom Ventilator System non-Viking ventilator kit will void the hood warranty.
5. WARNING!: To reduce risk of fire, use only
Dimensions & Specifications _____________________________________________________ 31 metal ductwork
6. CAUTION!: To reduce risk of fire and to
Installing Hood Canopy _________________________________________________________ 32 READ AND SAVE THESE INSTRUCTIONS properly exhaust air, be sure to duct air outside.
Clearance Dimensions ___________________________________________________________ 33 Do not vent exhaust air into spaces within walls
VICV Ventilator Dimensions ______________________________________________________ 34 or ceilings, or into attics, crawl spaces, or
Planning Information________________________________________________________________ 36 garages.
Installation Procedures 7. CAUTION!: To Reduce the Risk of Fire and
Electric Shock, Install this rangehood only with
Installation (VWH 10H. Wall Hoods w/Standard Ventilator) __________________________ 37 remote blower models manufactured by Viking,
Duct Cover Option (VWH 10H. Wall Hoods w/Standard Ventilator)___________________ 39 model numbers DEV900/DEV1200,
Installation (VWH 10H. Wall Hoods w/Recirculating Kit) _____________________________ 39 VEV900/VEV1200, OR DEV1500, VEV1500 or
Installation (VWH 18H. Wall & VCWH Chimney Wall Hoods) ________________________ 42 integral blowers manufactured by Viking, model
Duct Cover Option (VWH 18H. Wall Hoods)_______________________________________ 43 numbers DIV300, DIV440, DIV600, DIV800,
DIV1200, VIV300, VIV600, or VIV1200. NOTE
Duct Cover Option (VCWH Chimney Wall Hoods) __________________________________ 44 Please refer inside for specific canopy/blower
Installation (VIH/VCIH Island Hoods) ______________________________________________ 45 combinations.
Service & Registration_______________________________________________________________ 47

2 3
IMPORTANTPlease Read and Follow! Dimensions & Specifications
(VWH 10H. Wall Hoods w/Standard Ventilator 24, 30, & 36)

WARNING
To reduce the risk of injury to persons in the
event of a rangetop grease fire, observe the
following. (Based on Kitchen Firesafety Tips,
published by NFPA.)
1. SMOTHER FLAMES with a close fitted lid, cookie
sheet, or metal tray, then turn off the burner. BE
CAREFUL TO PREVENT BURNS. If the flames do
not go out immediately, EVACUATE AND CALL
THE FIRE DEPARTMENT.
1
2. NEVER PICK UP A FLAMING PAN. You may be (30 2
(7. 3
burned. .5
cm
3. DO NOT USE WATER, including wet dishcloths or 6 cm )
towels a violent steam explosion will result. )
4. Use an extinguisher ONLY if
1
You know it is a Class ABC extinguisher, and you (25 0
already know how to operate it. .4
cm
The fire is small and contained in the area where )
it started.
The fire department is being called. A (Hood width)
You can fight the fire with your back to an exit. 24W. 23-7/8 (60.6 cm) A 21 cm)
.3
30W. 29-7/8 (76.2 cm) (53
36W. 35-7/8 (91.1 cm)
CAUTION
For general ventilating use only. Do not use to
exhaust hazardous or explosive materials and NOTE: Optional duct cover sold separately.
vapors.
VWH 10H. Wall Hoods w/Standard Ventilator
WARNING Description 24 30 36
Duct cover width 23-7/8 (60.6 cm) 29-7/8 (75.9 cm) 35-7/8 (91.1 cm)
TO REDUCE THE RISK OF FIRE,
ELECTRICAL SHOCK, OR INJURY Duct cover depth 12 (30.5 cm)
TO PERSONS Duct cover height 12 (30.5 cm)
Rangehoods must be installed with
Number of lights 2
the ventilators that are specified on
their carton indicating suitability with Number of filters 2
this model. Other ventilators cannot be substituted. Heat lamps N/A
Interior ventilator kit 460 CFM Standard
Interior duct size* 7 (17.8 cm)
InteriorMaximum amps 5.6
* Disregard when using recirculating kits.
460 CFM blower is shipped with hood.

4 5
Clearance Dimensions Interior Ventilator Dimensions
(VWH 10H. Wall Hoods w/Standard Ventilator) (VWH 10H. Wall Hoods w/Standard Ventilator)

Top View

A
24W. 23-7/8 (60.6 cm) A
30W. 29-7/8 (75.9 cm) 18
36W. 35-7/8 (91.1 cm) B (4.6 cm) D
3-4 1/2
B C (1.9 cm)
(1.3 cm)
24W. 5-1/4 (13.3 cm)
60 24 4 3-1/2
(15 m (61mi
30W. 8-1/4 (20.9 cm)
(10.2 cm) (8.9 cm)
2.4 in. .0 n. 36W. 11-1/4 (28.6 cm)
c c
63 t o m) 27 to m)

(16 ma m C 3-7/8 Electrical
0.0 x. (68 ax
.6 .* 24W. 11-15/16 (30.3 cm) (9.8 cm) hookup
cm cm
) ) 30W. 14-15/16 (37.9 cm)
36W. 17-15/16 (45.6 cm) 7 (17.8 cm) dia.
duct location

3 6 cm ) D
.4 24W. 5/8 (1.6 cm)
(91
30W. 3-5/8 (9.2 cm)
36W. 6-5/8 (16.8 cm)

460 CFM Interior Ventilator Installation

* NOTE: When installing with a 24 high-shelf,


the 27 (68.6 cm) max. dimensions must be used.

6 7
Dimensions & Specifications Clearance Dimensions
(VWH 18H. 24 Deep Wall Hoods 24, 30, 36, 42, 48, 54, 60, & 66) (VWH 18H. Wall Hoods)
(VWH 18H. 27 Deep Wall Hoods 30, 36, 42, 48, 54, 60, & 66)

A (Hood width)
24W. 23-7/8 (60.6 cm)
30W. 29-7/8 (76.2 cm) 1
(30 2
.5
36W. 35-7/8 (91.1 cm) cm
)
42W. 41-7/8 (106.4 cm)
48W. 47-7/8 (121.6 cm)
(15 6
54W. 53-7/8 (136.8 cm) .2 1
cm
) (45 8
60W. 59-7/8 (152.1 cm) .7
cm
66W. 65-7/8 (167.3 cm) )

B (Hood depth)
24D. 24 (61.0 cm) A B
27D. 27 (68.6 cm)

66
NOTE: Optional duct cover sold separately. (16 m
7.6 in.
c 30
VWH 18H. Wall Hoods 7 2 t o m) (76mi

(18 ma .2 n.
Description 24 30 36 42 48 54 60 66 c
2.9 x.
cm 3 6 t o m)
Duct cover width 23-7/8 29-7/8 35-7/8 41-7/8 47-7/8 53-7/8 59-7/8 65-7/8 ) (91ma
(60.6 cm) (75.9 cm) (91.1 cm) (106.4 cm) (121.6 cm) (136.8 cm) (152.1 cm) (167.3 cm) .4 x.
cm
)
Duct cover depth 12 (30.5 cm)
Duct cover height 12 (30.5 cm)
36 cm)
Number of lights 2 2 2 2 3 3 4 4 .4
(91
Number of filters 2 2 2 2 3 3 4 4
Heat lamps 1 1 1 1 2 2 2 2
Interior ventilator kits VINV300/ VINV300/ VINV300/ VINV600/ VINV1200* VINV1200* VINV1200* VINV1200*
600 600/1200 600/1200 1200
Exterior ventilator kits DEV900/ DEV900/ DEV900/ DEV900/ DEV1200*/ DEV1200*/ DEV1200*/ DEV1200*/
1200* 1200* 1200* 1200* 1500** 1500** 1500** 1500**
In-line ventilator kits DIL900/1200 DIL900/1200 DIL900/1200 DIL900/1200 DIL1200 DIL1200 DIL1200 DIL1200
Interior duct size 7 7/10 7/10 7/10 10 10 10 10
(17.8 cm) (17.8/25.4 cm) (17.8/25.4 cm) (17.8/25.4 cm) (25.4 cm) (25.4 cm) (25.4 cm) (25.4 cm)
Exterior duct size 10 (25.4 cm)
InteriorMaximum amps 4.9/5.9 4.9/5.9 4.9/5.9 11.5 11.5 11.5 11.5 11.5
ExteriorMaximum amps 8.7/6.0 8.7/6.0 8.7/6.0 8.7/6.0 8.5/9.2 8.5/9.2 8.9/9.2 8.9/9.2
In-LineMaximum amps 6.0/7.9 6.0/7.9 6.0/7.9 6.0/7.9 10.3 10.3 10.7 10.7

* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.
Max duct run is 50 ft.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-
wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18H. hoods.

8 9
Interior Ventilator Dimensions Exterior Ventilator Dimensions
(VWH 18H. Wall Hoods) (VWH 18H. Wall Hoods)

Top View Top View


A A
18-3/4 1-1/16 8-1/4
(47.6 cm) 5/8 (20.9 cm)
(1.6 cm) 5-15/16 (2.7 cm)
9-3/8 (15.1 cm)
(23.8 cm)
A 6-7/16 B
A B 24W. 11-15/16 (30.3 cm) (16.4 cm) 24W. 23-7/8 (60.6 cm)
24W. 11-15/16 (30.3 cm) 9-1/8 24W. 23-7/8 (60.6 cm) 30W. 14-15/16 (37.9 cm) 30W. 29-7/8 (75.9 cm)
30W. 14-15/16 (37.9 cm) 4-5/8 30W. 29-7/8 (75.9 cm) 9-3/4 120
(23.2 cm) 36W. 17-15/16 (45.6 cm) (24.8 cm) V 3 (7.62 cm) 36W. 35-7/8 (91.1 cm)
120
36W. 17-15/16 (45.6 cm) (11.7 cm) V 36W. 35-7/8 (91.1 cm)
42W. 20-15/16 (53.2 cm) 42W. 41-7/8 (106.4 cm)
42W. 20-15/16 (53.2 cm) 9-5/8 42W. 41-7/8 (106.4 cm)
(24.4 cm) 48W. 23-15/16 (60.8 cm) 2-1/2 48W. 47-7/8 (121.6 cm)
48W. 23-15/16 (60.8 cm) 48W. 47-7/8 (121.6 cm) (6.35 cm)
54W. 26-15/16 (68.4 cm) 54W. 53-7/8 (136.8 cm)
54W. 26-15/16 (68.4 cm) 54W. 53-7/8 (136.8 cm)
60W. 29-15/16 (76.0 cm) 60W. 59-7/8 (152.1 cm)
60W. 29-15/16 (76.0 cm) 7(17.8 cm) dia. 60W. 59-7/8 (152.1 cm) 10 (25.4 cm) dia.
duct location 66W. 32-15/16 (83.7 cm) duct location 66W. 65-7/8 (167.3 cm)
66W. 32-15/16 (83.7 cm) 66W. 65-7/8 (167.3 cm)

B B

300 or 600 CFM Interior Ventilator Installation for all Wall Hoods 900 or 1200 CFM Exterior Ventilator Installation for all Wall Hoods

Top View Top View


18-1/2 A
(50.0 cm) A
5-15/16
9-3/8 5/8 (15.1 cm) 8-3/16
(23.8 cm) (1.6 cm) (20.7 cm)

A B A 6-5/8 B
5-1/2
24W. 11-15/16 (30.3 cm) (14.0 cm) 8-3/8 24W. 23-7/8 (60.6 cm) 24W. 11-15/16 (30.3 cm) 9-3/4 (16.8 cm) 24W. 23-7/8 (60.6 cm)
30W. 14-15/16 (37.9 cm) 120 (21.3 cm) 30W. 29-7/8 (75.9 cm) 30W. 14-15/16 (37.9 cm) (24.8 cm) 120
3 (7.62 cm) 30W. 29-7/8 (75.9 cm)
V V
36W. 17-15/16 (45.6 cm) 36W. 35-7/8 (91.1 cm) 36W. 17-15/16 (45.6 cm) 36W. 35-7/8 (91.1 cm)
42W. 20-15/16 (53.2 cm) 42W. 41-7/8 (106.4 cm) 42W. 20-15/16 (53.2 cm) 42W. 41-7/8 (106.4 cm)
2-1/2
48W. 23-15/16 (60.8 cm) 9-1/4 9-1/2 48W. 47-7/8 (121.6 cm) 48W. 23-15/16 (60.8 cm) 48W. 47-7/8 (121.6 cm)
(23.5 cm) (24.1 cm)
(6.35 cm)
54W. 26-15/16 (68.4 cm) 54W. 53-7/8 (136.8 cm) 54W. 26-15/16 (68.4 cm) 54W. 53-7/8 (136.8 cm)
10 (25.4 cm) dia.
60W. 29-15/16 (76.0 cm) 10 (25.4 cm) dia. 60W. 59-7/8 (152.1 cm) 60W. 29-15/16 (76.0 cm) duct location 60W. 59-7/8 (152.1 cm)
66W. 32-15/16 (83.7 cm) duct location 66W. 65-7/8 (167.3 cm) 66W. 32-15/16 (83.7 cm) 66W. 65-7/8 (167.3 cm)
B B

1200 CFM Interior Ventilator Installation for all Wall Hoods 1200 or 1500 CFM Exterior Ventilator Installation for all Wall Hoods

10 11
Dimensions & Specifications Clearance Dimensions
(VWH 18H. T-Series Wall Hoods 36, 48, & 60) (VWH 18H. T-Series Wall Hoods)

Seal joints with silicone.


Provided on T Series only.

18 )
1 cm
(30 2 5.7
(4
.
5c X
m) I M /2
D 4-1 m)
+ 1.4 c
(1
(15 6
.2 1
cm
) (45 8
.7
cm
)
27 cm)
8.6
66 (6
A (Hood width) (1 6 m
7.6 in.
36W. 35-7/8 (91.1 cm) A 27 m) c c 30
.6 72 to m) (76 mi
48W. 47-7/8 (121.6 cm) (68 (18 m . 2 n.
2.9 ax. c
36 t o m)
60W. 59-7/8 (152.1 cm) cm m
) (91 a
.4 x.
cm
)

NOTE: Optional duct cover sold separately.


VWH 18H. T-Series Wall Hoods 36 cm)
.4
(91
Description 36 48 60
Duct cover width 35-7/8 (91.1 cm) 47-7/8 (121.6 cm) 59-7/8 (152.1 cm)
Duct cover depth 12 (30.5 cm)
Duct cover height 12 (30.5 cm)
Number of lights 2 3 4
Number of filters 2 3 4
Interior ventilator kits VINV1200* VINV1200* VINV1200*
Exterior ventilator kits DEV1200*/1500** DEV1200*/1500** DEV1200*/1500**
In-line ventilator kits DIL1200 DIL1200 DIL1200
Interior duct size 10 (25.4 cm)
Exterior duct size 10 (25.4 cm)
InteriorMaximum amps 9.0 11.4 11.8 Note: T-Series Models must be installed in a covered, non-enclosed area, and should be protected from
ExteriorMaximum amps 6.1/6.8 8.4/9.1 8.8/9.5 the elements as much as possible.
In-LineMaximum amps 7.9 10.2 10.6
The bottom of the hood should be 30 (76.2 cm) to 36 (91.4 cm) above the grill surface. The hood
* A 1,200 CFM interior- or exterior-power ventilator should be used with all T-Series models and when indoor models are
should be installed 4-1/2 (11.4 cm) plus the distance between the back trim and surface from the back
installed over range/rangetop with gas char-grill. Max duct run is 50 ft. wall. (Note: There is a 3 minimum clearance from the back trim to non-combustible surfaces, and a 24
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft. minimum to combustible surfaces.) This will require building the hood out from the wall. Any combustible
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2- material used for this purpose must be covered with locally-supplied stainless steel. Viking also
wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18H. hoods. recommends using a backsplash.

12 13
Dimensions & Specifications Clearance Dimensions
(VCWH Chimney Wall Hoods 30, 36, 42, 48, 54, 60, & 66) (VCWH Chimney Wall Hoods)
A

A (Duct width)
30W. 12 (30.5 cm)
36W. 12 (30.5 cm)
42W. 12 (30.5 cm)
48W. 18 (45.7 cm)
1
(30 2
.5
54W. 18 (45.7 cm) c
to m)
60W. 24 (61.0 cm) 2
(61 4
66W. 24 (61.0 cm) .0
cm
(15 6 )
B (Hood width) .2
c m)
30W. 29-7/8 (76.2 cm) 1
(45 8
36W. 35-7/8 (91.1 cm) .7
cm
42W. 41-7/8 (106.4 cm) )
48W. 47-7/8 (121.6 cm)
54W. 53-7/8 (136.8 cm)
B
60W. 59-7/8 (152.1 cm) 24 cm)
66W. 65-7/8 (167.3 cm) .0 66
(61 (16 m
7.6 in.
c 30
7 2 t o m) (76mi
NOTE: Optional duct cover sold separately.
(18 ma .2 n.
c
2.9 x. 3 6 t o m)
VCWH Chimney Wall Hoods cm
) (91ma
.4 x.
Description 30 36 42 48 54 60 66 cm
)
Duct cover width 12 (30.5 cm) 12 (30.5 cm) 12 (30.5 cm) 18 (45.7 cm) 18 (45.7 cm) 24 (61.0 cm) 24 (61.0 cm)

Duct cover depth 12 (30.5 cm) 36 cm)
.4
Duct cover height 12 (30.5 cm) to 24 (61.0 cm) (91
Number of lights 2 2 2 3 3 4 4
Number of filters 2 2 2 2 3 3 3
Heat lamps 1 1 1 2 2 2 2
Interior ventilator kits VINV300/600 VINV300/600 VINV600 VINV1200* VINV1200* VINV1200* VINV1200*
Exterior ventilator kits DEV900/ DEV900/ DEV900/ DEV1200*/ DEV1200*/ DEV1200*/ DEV1200*/
1200* 1200* 1200* 1500** 1500** 1500** 1500**
In-line ventilator kits DIL900/1200 DIL900/1200 DIL900/1200 DIL1200 DIL1200 DIL1200 DIL1200
Interior duct size 7 (17.8 cm) 7 (17.8 cm) 7 (17.8 cm) 10 (25.4 cm) 10 (25.4 cm) 10 (25.4 cm) 10 (25.4 cm)
Exterior duct size 10 (25.4 cm)
InteriorMaximum amps 4.9/5.9 4.9/5.9 5.9 11.5 11.5 11.9 11.9
ExteriorMaximum amps 8.7/6.0 8.7/6.0 8.7/6.0 8.5/9.2 8.5/9.2 8.5/9.2 8.5/9.2
In-LineMaximum amps 6.0/7.9 6.0/7.9 6.0/7.9 10.3 10.3 10.7 10.7

* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.
Max duct run is 50 ft.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-
wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18H. hoods.

14 15
Interior Ventilator Dimensions Exterior Ventilator Dimensions
(VCWH Chimney Wall Hoods) (VCWH Chimney Wall Hoods)

Top View Top View


120V 120V
12 power
12 power
(30.5 cm) supply
(30.5 cm) supply 1-1/2
1-1/2
(3.8 cm)
(3.8 cm) A
A

A 8
A 8 30W. 14-15/16 (37.9 cm) (20.3 cm)
30W. 14-15/16 (37.9 cm) (20.3 cm)
36W. 17-15/16 (45.6 cm) 1-1/2
36W. 17-15/16 (45.6 cm) 1-1/2
42W. 20-15/16 (53.2 cm) (3.8 cm)
42W. 20-15/16 (53.2 cm) (3.8 cm)

B
B
30W. 29-7/8 (75.9 cm)
30W. 29-7/8 (75.9 cm)
36W. 35-7/8 (91.1 cm)
36W. 35-7/8 (91.1 cm) 10 (25.4 cm) dia.
7 (17.8 cm) dia. 42W. 41-7/8 (106.4 cm)
42W. 41-7/8 (106.4 cm) duct location
duct location

B
B

300 or 600 CFM Interior Ventilator Installation 900 or 1200 CFM Exterior or In-Line Ventilator Installation
for 30, 36, & 42 models for 30, 36, & 42 models

Top View Top View 120 V


120 V
power 1-1/2 power
1-1/2 C
C supply (3.8 cm) supply
(3.8 cm)
A A

A C A 6 C
6
48W. 23-15/16 (60.8 cm) 48W. 18 (45.7 cm) 48W. 23-15/16 (60.8 cm) (15.2 cm) 48W. 18 (45.7 cm)
(15.2 cm) 1-1/2
54W. 26-15/16 (68.4 cm) 1-1/2 54W. 18 (45.7 cm) 54W. 26-15/16 (68.4 cm) 54W. 18 (45.7 cm)
60W. 29-15/16 (76.0 cm) (3.8 cm) 60W. 24 (61.0 cm)
(3.8 cm)
60W. 29-15/16 (76.0 cm) 60W. 24 (61.0 cm)
66W. 32-15/16 (83.7 cm) 66W. 24 (61.0 cm) 66W. 32-15/16 (83.7 cm) 66W. 24 (61.0 cm)
B
B
48W. 47-7/8 (121.6 cm)
54W. 53-7/8 (136.8 cm) 48W. 47-7/8 (121.6 cm)
10 (25.4 cm) dia.
60W. 59-7/8 (152.1 cm) 10 (25.4 cm) dia. 54W. 53-7/8 (136.8 cm) duct location
66W. 65-7/8 (167.3 cm)
duct location 60W. 59-7/8 (152.1 cm)
66W. 65-7/8 (167.3 cm)
B B

1200 CFM Interior Ventilator Installation 900, 1200 or 1500 CFM Exterior or In-Line Ventilator Installation
for 48, 54, 60, & 66 models for 48, 54, 60, & 66 models

16 17
Dimensions & Specifications Clearance Dimensions
(VIH Island Hoods 36, 42, 54, & 66) (VIH Island Hoods)

1
(30 2
(15 6 .5
cm
.2 )
cm
)

1
(45 8
.7
cm
)
A (Hood width)
36W. 35-7/8 (91.1 cm)

42W. 41-7/8 (106.4 cm) A 30 cm)
.2 66
54W. 53-7/8 (136.8 cm) (76 (16 m
7.6 in.
66W. 65-7/8 (167.3 cm) c 30
72 t o m) (76mi

(18 ma .2 n.
c
NOTE: Optional duct cover sold separately. 2.9 x.
cm 36 to m)
)
(91 ma
VIH Island Hoods .4 x.
cm
)
Description 36 42 54 66

Duct cover width 35-7/8 (91.1 cm) 41-7/8 (106.4 cm) 53-7/8 (136.8 cm) 65-7/8 (167.3 cm) 3 6 cm )
.4
Duct cover depth 12 (30.5 cm) (91
Duct cover height 12 (30.5 cm)
Number of lights 4 4 6 8
Number of filters 4 4 6 8
Heat lamps N/A
Interior ventilator kits VINV600/1200* VINV600/1200* VINV1200* VINV1200*
Exterior ventilator kits DEV900/1200* DEV900/1200*/1500** DEV1200*/1500** DEV1200*/1500**
In-line ventilator kits DIL900/1200 DIL900/1200 DIL1200 DIL1200
Interior duct size 7 (17.8 cm)/ 7 (17.8 cm)/ 10 (25.4 cm) 10 (25.4 cm)
10 (25.4 cm) 10 (25.4 cm)
Exterior duct size 10 (25.4 cm)
InteriorMaximum amps 4.6/7.7 4.6/7.7 8.5 9.3
ExteriorMaximum amps 7.4/4.7 7.4/4.7/5.5 5.5/6.2 6.3/7.1
In-LineMaximum amps 4.7/6.5 4.7/6.5 7.3 8.1

* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.
Max duct run is 50 ft.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-
wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18H. hoods.

18 19
Interior Ventilator Dimensions Exterior Ventilator Dimensions
(VIH Island Hoods) (VIH Island Hoods)

Top View Top View


A A

A A
18-3/4 (47.6 cm) 1-1/16
36W. 17-15/16 (45.6 cm) 5/8 36W. 17-15/16 (45.6 cm) (2.7 cm) 8-1/4
9-3/8 (1.6 cm)
42W. 20-15/16 (18.2 cm) (23.8 cm) 42W. 20-15/16 (18.2 cm) (20.9 cm)
54W. 26-15/16 (68.4 cm) 54W. 26-15/16 (68.4 cm)
66W. 32-15/16 (83.7 cm) 66W. 32-15/16 (83.7 cm) 5-15/16 6-7/16
9-1/8 (15.1 cm) (16.4 cm)
B 4-5/8 (23.2 cm) B
120
36W. 35-7/8 (91.1 cm)
9-3/4 120
3 (7.62 cm)
36W. 35-7/8 (91.1 cm) (11.7 cm) V V
(24.8 cm)
42W. 41-7/8 (106.4 cm) 42W. 41-7/8 (106.4 cm)
54W. 53-7/8 (136.8 cm) 54W. 53-7/8 (136.8 cm)
9-5/8 10 2-1/2
66W. 65-7/8 (167.3 cm) (24.4 cm) 66W. 65-7/8 (167.3 cm)
(25.4 cm) dia. (6.35 cm)
7 (17.8 cm) dia.
duct location duct location

B B

600 CFM Interior Ventilator Installation 900 or 1200 CFM Exterior or In-Line Ventilator Installation
for all Island Hoods for all Island Hoods

Top View Top View


A
A

A A
36W. 17-15/16 (45.6 cm) 36W. 17-15/16 (45.6 cm)
18-1/8 8-3/16
42W. 20-15/16 (18.2 cm) (50.0 cm) 9-3/8 42W. 20-15/16 (18.2 cm)
(23.8 cm) (20.7 cm)
54W. 26-15/16 (68.4 cm) 54W. 26-15/16 (68.4 cm)
66W. 32-15/16 (83.7 cm) 5-1/2 66W. 32-15/16 (83.7 cm) 5-15/16 6-5/8
(14 cm) 8-3/8 (15.1 cm) (6.35 cm)
B (21.3 cm) B
120 120
36W. 35-7/8 (91.1 cm) V 36W. 35-7/8 (91.1 cm) 9-3/4 3 (7.62 cm)
V
(24.8 cm)
42W. 41-7/8 (106.4 cm) 42W. 41-7/8 (106.4 cm)
54W. 53-7/8 (136.8 cm) 54W. 53-7/8 (136.8 cm)
10 9-1/4 9-1/2 10 2-1/2
66W. 65-7/8 (167.3 cm) (25.4 cm) dia. 66W. 65-7/8 (167.3 cm)
(23.5 cm) (24.1 cm) (25.4 cm) dia. (6.35 cm)
duct location duct location
18-3/4 (47.6 cm)
B B

1200 CFM Interior Ventilator Installation 900, 1200 or 1500 CFM Exterior or In-Line Ventilator Installation
for all Island Hoods for all Island Hoods

20 21
Dimensions & Specifications Clearance Dimensions
(VCIH Chimney Island Hoods 36, 42, 54, & 66) (VCIH Chimney Island Hoods)
A

A (Duct width)
36W. 12 (30.5 cm)
42W. 12 (30.5 cm)
54W. 18 (45.7 cm)
66W. 24 (70.0 cm)

B (Duct height) (15 6 B


.2
36W. 12 (30.5 cm) cm
)
42W. or
24 (61.0 cm)
54W. 1
(45 8
or
66W. .7
36 (91.4 cm) cm
)
C (Hood width)
36W. 35-7/8 (91.1 cm)
C 30 cm)
42W. 41-7/8 (106.4 cm) .2 66
(76 (16 m
54W. 53-7/8 (136.8 cm) 7.6 in.
c 30
66W. 65-7/8 (167.3 cm) 72 t o m) (76mi

(18 ma .2 n.
c
NOTE: Optional duct cover sold separately.
2.9 x.
cm 36 to m)
)
(91 ma
.4 x.
VCIH Chimney Island Hoods c
m)
Description 36 42 54 66

Duct cover width 12 (30.5 cm) 12 (30.5 cm) 18 (45.7 cm) 24 (70.0 cm) 3 6 cm )
.4
Duct cover depth 12 (30.5 cm) (91
Duct cover height 12 (30.5 cm) or 24 (61.0 cm) or 36 (91.4 cm)
Number of lights 4 4 6 8
Number of filters 4 4 6 8
Heat lamps N/A
Interior ventilator kits VINV600 VINV600 VINV1200* VINV1200*
Exterior ventilator kits DEV900/1200* DEV900/1200*/1500** DEV1200*/1500** DEV1200*/1500**
In-line ventilator kits DIL900/1200 DIL900/1200 DIL1200 DIL1200
Interior duct size 7 (17.8 cm) 7 (17.8 cm) 10 (25.4 cm) 10 (25.4 cm)

Exterior duct size 10 (25.4 cm)


InteriorMaximum amps 4.6 4.6 8.9 9.3
ExteriorMaximum amps 7.4/4.7 7.4/4.7/5.5 5.6/6.4 6.4/7.4
In-LineMaximum amps 4.7/6.5 3.9/5.7 7.4 7.4

* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.
Max duct run is 50 ft.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-
wire with ground. An interior or exterior-power ventilator kit must be purchased for installation with all 18H. hoods.

22 23
Interior Ventilator Dimensions Exterior Ventilator Dimensions
(VCIH Chimney Island Hoods) (VCIH Chimney Island Hoods)

Top View Top View


12 1-1/8 12 1-1/8
(30.5 cm) (2.9 cm) (30.5 cm) (2.9 cm)

120 V 120 V
A power A power
A A
36W. 17-15/16 (45.6 cm) supply 36W. 17-15/16 (45.6 cm) supply
42W. 20-15/16 (53.2 cm) 42W. 20-15/16 (53.2 cm)
1-1/8 1-1/8
6 6
B (2.9 cm) B (2.9 cm)
(15.2 cm) (15.2 cm)
36W. 35-7/8 (91.1 cm) 36W. 35-7/8 (91.1 cm)
42W. 41-7/8 (106.4 cm) 42W. 41-7/8 (106.4 cm)

7 (17.8 cm) dia. 10 (25.4 cm) dia.


duct location duct location
B B

600 CFM Interior Ventilator Installation 900 or 1200 CFM Exterior or In-Line Ventilator Installation
for all Chimney Island Hoods for all Chimney Island Hoods

Top View Top View


C 1-1/8
(2.9 cm) C 1-1/8
120 V (2.9 cm)
A power 120 V
54W. 26-15/16 (68.4 cm) supply A power
A
54W. 26-15/16 (68.4 cm) A supply
66W. 32-15/16 (83.7 cm) 1-1/8
(2.9 cm) 66W. 32-15/16 (83.7 cm) 1-1/8
B 6 (2.9 cm)
(15.2 cm) B 6
54W. 53-7/8 (136.8 cm) (15.2 cm)
54W. 53-7/8 (136.8 cm)
66W. 65-7/8 (167.3 cm)
66W. 65-7/8 (167.3 cm)
C
54W. 18 (45.7 cm) C
10 (25.4 cm) dia. 54W. 18 (45.7 cm)
66W. 24 (61.0 cm) 10 (25.4 cm) dia.
duct location
66W. 24 (61.0 cm) duct location
B
B

1200 CFM Interior Ventilator Installation 900, 1200 or 1500 CFM Exterior or In-Line Ventilator Installation
for all Chimney Island Hoods for all Chimney Island Hoods

24 25
Dimensions & Specifications Installing Hood Canopy
(VBCV Wall Custom Ventilator System 30, 36, 42, 48, 54, 60 & 66) (Custom Hood Canopy Cutouts)
A*

*For best results, Make sure the back wall


Custom Hood
center the unit over B* of the custom hood Canopy
the burners of the canopy is flush with the
cooking product cutout so the ventilator
A
(front to back; right system may be mounted
B
to left). as shown on page 25.

Bottom Cutout Dimensions


Wall Hoods
Description A (Hood Width) B (Hood Depth)
30 W. 27-7/16 (69.7 cm) 21-7/16 (54.5 cm)
36 W. 33-7/16 (84.9 cm) 21-7/16 (54.5 cm)
42 W. 39-7/16 (100.2 cm) 21-7/16 (54.5 cm)
48 W. 45-7/16 (115.4 cm) 21-7/16 (54.5 cm)
54 W. 51-7/16 (130.7 cm) 21-7/16 (54.5 cm)
1) Position ventilator
60 W. 57-7/16 (145.9 cm) 21-7/16 (54.5 cm) system inside of the
66 W. 63-7/16 (161.1 cm) 21-7/16 (54.5 cm) custom hood canopy
and center it front to Built-In Ventilator
VBCV Wall Custom Ventilator System back and left to right.
System
Description 30 36 42 48 54 60 66 2) Bottom mounting holes
Number of lights 2 2 2 3 3 4 4 fasten ventilator system
Number of filters 2 2 2 3 3 4 4 to bottom of custom
Heat lamps 1 1 1 2 2 2 2 hood canopy with the
Interior ventilator kits VINV300/ VINV300/ VINV600/ VINV1200* VINV1200* VINV1200* VINV1200* screws provided.
600/1200* 600/1200* 1200*
Exterior ventilator kits DEV900/ DEV900/ DEV900/ DEV1200*/ DEV1200*/ DEV1200*/ DEV1200*/
1200* 1200* 1200* 1500** 1500** 1500** 1500** 3) OPTIONAL
In-line ventilator kits DIL900/1200 DIL900/1200 DIL900/1200 DIL1200 DIL1200 DIL1200 DIL1200 Rear mounting holes fasten
Interior duct size 7/10 7/10 7/10 10 10 10 10 ventilator system to rear of
(17.8/25.4 cm) (17.8/25.4 cm) (17.8/25.4 cm) (25.4 cm) (25.4 cm) (25.4 cm) (25.4 cm) custom hood canopy.
Exterior duct size 10 (25.4 cm)
InteriorMaximum amps 5.9/9.0 5.9/9.0 5.9/9.0 11.5 11.5 11.9 11.9
ExteriorMaximum amps 8.7/6.0 8.7/6.0 8.7/6.0 8.5/9.2 8.5/9.2 8.9/9.2 8.9/9.2
In-LineMaximum amps 6.0/7.9 6.0/7.9 6.0/7.9 10.3 10.3 10.7 10.7

* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.
Max duct run is 50 ft.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-
wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18H. hoods.

26 27
Clearance Dimensions Built-In Wall Custom Ventilator
(VBCV Wall Custom Ventilator System) System Dimensions (VBCV Models)

1-1/2 7/8
1 (3.8 cm)
1-1/2 (2.54 cm) (2.2 cm)
(3.81 cm)

(Cu
sto 11-1/2
m (29.2 cm)
Ho
od
)
17-1/4
(43.8 cm)

6
5/8 (15.2 cm) 5/8
(1.6 cm) (1.6 cm)
66 21-7/8 21-7/8
(16 m (55.8 cm) (55.8 cm)
7.6 in.
c 30
7 2 t o m) (76mi For 900, 1200 or 1500 CFM Exterior For 300, 600 or 1200 CFM Interior

(18 ma .2 n.
c or In-Line Ventilator Installation Ventilator Installation
2.9 x.
cm 3 6 t o m)
)
(91 ma
.4 x.
cm D
) D
8-1/4 9-3/8
(20.9 cm) (23.8 cm)
36 cm) 6 4-5/8
.4 5-1/2
(91 (14.0 cm) (15.2 cm) (11.7 cm) 9-1/4
7 (23.5 cm)
120
V 3 (7.6 cm) (17.8 cm) 120
V
dia. duct
location 9-5/8
10
(25.4 cm) dia. (24.4 cm)
duct location 2-1/2 (6.4 cm) 18-3/4 (47.6 cm)

5/8 (1.6 cm) 5/8 (1.6 cm)


C C

900 or 1200 CFM Exterior 300 or 600 CFM Interior


or In-Line Ventilator Installation Ventilator Installation
30, 36, 42 W. Models 30, 36, 42 W. Models

*Note: Dotted Line (........) represents cutout.

C D
30 W. 28-1/4 (71.8 cm) 30 W. 14-1/8 (35.9 cm)
36 W. 34-1/4 (87.0 cm) 36 W. 17-1/8 (43.5 cm)
42 W. 40-1/4 (102.2 cm) 42 W. 20-1/8 (51.1 cm)

28 29
Built-In Wall Custom Ventilator Dimensions & Specifications
System Dimensions (VBCV Models) (VICV Island Custom Ventilator System 36, 42, 54 & 66)

A*
D
8-1/4
(20.9 cm)
5-1/2 6
(14.0 cm) (15.2 cm)
120 *For best results, Make sure the back wall
3 (7.6 cm)
V
center the unit over B* of the custom hood
the burners of the canopy is flush with the
10
cooking product cutout so the ventilator
(25.4 cm) dia.
duct location 2-1/2 (6.4 cm) (front to back; right system may be mounted
to left). as shown on page 30.
5/8 (1.6 cm)
C

1200 or 1500 CFM Exterior or In-Line Ventilator Installation Bottom Cutout Dimensions
48, 54, 60, 66 W. Models

Island Hoods
Description A (Hood Width) B (Hood Depth)
18-1/2
(50.0 cm) D 36 W. 33-7/16 (84.9 cm) 27-9/16 (70.0 cm)
9-3/8 42 W. 39-7/16 (100.2 cm) 27-9/16 (70.0 cm)
(23.8 cm)
54 W. 51-7/16 (130.7 cm) 27-9/16 (70.0 cm)
5-1/2
(14.0 cm) 66 W. 63-7/16 (161.1 cm) 27-9/16 (70.0 cm)
8-3/8
10 (21.3 cm)
120
(25.4 cm) V
dia. duct
location
9-1/4 9-1/2 VICV Island Custom Ventilator System
(23.5 cm) (24.4 cm)
Description 36 42 54 66
Number of lights 4 4 6 8
5/8 (1.6 cm)
C Number of filters 4 4 6 8
Heat lamps N/A
1200 CFM Interior Ventilator Installation Interior ventilator kits VINV600/1200* VINV600/1200* VINV1200* VINV1200*
30, 36, 42, 48, 54, 60, 66 W. Models DEV900/1200* DEV900/1200*/1500** DEV1200*/1500** DEV1200*/1500**
Exterior ventilator kits
In-line ventilator kits DIL900/1200 DIL900/1200 DIL1200 DIL1200
*Note: Dotted Line (........) represents cutout. Interior duct size 7 (17.8 cm)/ 7 (17.8 cm)/ 10 (25.4 cm) 10 (25.4 cm)
10 (25.4 cm) 10 (25.4 cm)
Exterior duct size 10 (25.4 cm)
C D InteriorMaximum amps 4.6/7.7 4.6/7.7 8.5 9.3
30 W. 28-1/4 (71.8 cm) 30 W. 14-1/8 (35.9 cm) ExteriorMaximum amps 7.4/4.8 7.4/4.8/5.5 5.6/6.2 5.6/6.2
36 W. 34-1/4 (87.0 cm) 36 W. 17-1/8 (43.5 cm)
42 W. 40-1/4 (102.2 cm) 42 W. 20-1/8 (51.1 cm) In-LineMaximum amps 4.7/6.5 4.7/6.5 7.3 8.1
48 W. 46-1/4 (117.5 cm) 48 W. 23-1/8 (58.7 cm)
54 W. 52-1/4 (132.7 cm) * A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.
54 W. 26-1/8 (66.4 cm)
Max duct run is 50 ft.
60 W. 58-1/4 (148.0 cm) 60 W. 29-1/8 (74.0 cm) ** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
66 W. 64-1/4 (163.2 cm) 66 W. 32-1/8 (81.6 cm) NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-
wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18H. hoods.

30 31
Installing Hood Canopy Clearance Dimensions
(Custom Hood Canopy Cutouts) (VICV Island Custom Ventilator System)

Custom Hood
Canopy
A (Cu
B sto
m
Ho
od
)

66
(16 m
7.6 in.
c 30
7 2 t o m) (76mi

(18 ma .2 n.
c
2.9 x.
cm 3 6 to m)
)
(91 ma
1) Position ventilator .4 x.
cm
system inside of the )
custom hood canopy
and center it front to Built-In Ventilator 36 cm)
.4
back and left to right. (91
System
2) Bottom mounting holes
fasten ventilator system
to bottom of custom
hood canopy with the
screws provided.

3) OPTIONAL
Rear mounting holes fasten
ventilator system to rear of
custom hood canopy.

32 33
Built-In Island Custom Ventilator Built-In Island Custom Ventilator
System Dimensions (VICV Models) System Dimensions (VICV Models)

1-1/2 1 1-1/2
(3.8 cm) (3.8 cm) 11/16
(2.5 cm) (1.7 cm) A
B 18-3/4 (47.6 cm)

11-1/2 11-1/2 7/8


8-1/4
(29.2 cm) (29.2 cm) (2.2 cm)
17-1/4 (21.0 cm)
(43.8 cm)
5-3/4 5-1/2
(14.6 cm) 6 (15.2 cm)
(14.0 cm) 8-3/8
(21.3 cm)
120
3 (7.6 cm) 10 120
V
6 (25.4 cm) V
5/8 (15.2 cm) 5/8 dia. duct
(1.6 cm) (1.6 cm) location
10 9-1/4 9-1/2
27-7/16 (69.7 cm) 27-7/16 (69.7 cm)
(including screw heads) (including screw heads) (25.4 cm) dia. 2-1/2 (23.5 cm) (24.4 cm)
duct location (6.4 cm) 18-3/4 (47.6 cm)
28-7/16 (72.2 cm)
28-7/16 (72.2 cm) 5/8 (1.6 cm)
5/8 (1.6 cm)
A A
External Power Internal Power
900, 1200 or 1500 External or In-Line Power 1200 CFM Internal Power
B B 42, 54, 66 W. Models 42, 54, 66 W. Models
18-3/4 *Note: Dotted Line (........) represents cutout.
8-1/4 (47.6 cm)
(21.0 cm) 9-3/8
(23.8 cm)

5-3/4 A B
(14.6 cm) 6 (15.2 cm) 54 W. 52-1/4 (132.7 cm) 54 W. 26-1/8 (66.4 cm)
1-3/16 9-1/4
(3.0 cm) (23.5 cm) 66 W. 64-1/4 (163.2 cm) 66 W. 32-1/8 (81.6 cm)
120
V 3 (7.6 cm) 120
5-3/16 V
(13.2 cm)

10 7 9-5/8
(25.4 cm) dia. 2-1/2 (17.8 cm) dia. (24.4 cm)
duct location (6.4 cm) duct location

5/8 (1.6 cm) 5/8 (1.6 cm)


A A
900 or 1200 CFM External or In-Line Power 600 CFM Internal Power
36, 42 W. Models 36, 42 W. Models
*Note: Dotted Line (........) represents cutout.

A B
36 W. 34-1/4 (87.0 cm) 36 W. 17-1/8 (43.5 cm)
42 W. 40-1/4 (102.2 cm) 42 W. 20-1/8 (51.1 cm)

34 35
Installation (VWH 10H. Wall Hoods w/Standard Ventilator)

Planning Information 1 2

Proper installation of ducting is extremely


important to ensure maximum performance 300 or 600 CFM
Roof cap single blower
from any ventilation product.
7 round duct
interior-power
typical ductwork
4
All CFMs are based on tests at 0.1 static 5/16
pressure: without applying static pressure, CFM nut
driver
would be greatly overstated. Duct cover or soffit
Straight runs and gradual turns are best; for
example, each 90 elbow is equivalent to 5-10
feet (1.52-3.05 cm) of straight run.
Hood
Never use flexible duct; it creates back pressure/air
turbulence and greatly reduces performance. Check damper for unrestricted movement, adjust if Attach transition to damper. Seal with aluminum tape.
Proper performance is dependent on proper necessary.
ducting; make sure that a qualified and trained
1200 CFM
installer is used. Roof cap single blower
Check with a qualified and trained installer or interior power

local codes for makeup air requirement, if any.


Max. amp rating for hoods includes
10 round duct typical ductwork

3 WARNING
recommended ventilator kit rating; all products Duct cover or soffit To reduce the risk of fire, electric shock, or injury
must be hard wired direct with 2-wire with ground. to persons, observe the following:
Use this unit only in the manner intended by the
Plan where the duct work will be located. Install Hood manufacturer. If you have any questions, contact
proper-sized duct work, and roof or wall cap for the
the manufacturer.
type of blower you are using. Recommended hood Before servicing or cleaning unit, switch power off
locations for the most common installations are at service panel and lock service panel to prevent
shown. Adjust your measurements for various heights 900, 1200, or power from being switched on accidentally. When
Exterior blower 1500 CFM
of ceilings, soffits, cabinets, or ranges/rangetops. exterior power the service disconnecting means cannot be locked,
10 round duct typical ductwork securely fasten a prominent warning device, such
Check Framing as a tag, to the service panel.
Duct cover or soffit

Flip hood over and remove electrical box cover.

Hood

Wall Installation
exterior power 4 5
Wall cap typical ductwork 1
2
Duct
Duct cover or soffit

1
Hood

NOTE: Because of the weight of the hood make sure NOTE: Wall exhaust must be a minimum of 24 (61.0 cm)
that the mounting screws are driven into the framing from ground. This may vary depending on local codes
and geographic location.
and not just the drywall. It may be necessary to drill
additional holes in the canopy for proper alignment. Electrical Supply
Run 120 VAC electrical wiring from service panel
to installation location. See Specifications pages Insert 6 of electrical wiring through the top of vent hood Slide duct over transition and tape around joint.
for the maximum amp requirements. and secure using wiring restrain. Refer to local codes.

36 37
6 11
1

5/16
nut driver
5/16

3
nut driver 2

Slide filter front over front lip. Push filter rear up, then
CAUTION: Secure vent hood to wall using screws CAUTION: If not using a duct cover, using screws
slide back over rear lip.
provided. Use additional mounting screws and wall provided, make sure top mounting screws are secured
anchors, if necessary. into soffit or cabinet framing. Use additional mounting
screws, if necessary. Duct Cover Option (VWH 10H. Wall Hoods w/Standard Ventilator)

7 BARE OR GREEN 8 1 2 2

1
1
GREEN
2
BLACK
WHITE

BLACK
WHITE

Connect black to black, white to white, and the Replace electrical box cover. Make connection to Measure distance from ceiling to canopy. Slide the duct cover in place and fasten from inside
green/bare wire under the green screw. breaker box. canopy using the sheet metal screws provided.
NOTE: Housing wiring must be properly installed for
wiring to be correct when wiring unit. Installation (VWH 10H. Wall Hoods w/Recirculating Kit)

9 10 1 2
1
1

3 3
2 2

Slide filter front over front lip. Push filter rear up, then Slide spacer front over front lip. Push spacer rear up, Remove damper and discard with transition. Turn recirculating unit upside down. Place vent hood
slide back over rear lip. then slide back over rear lip. upside down on recirculating unit.

38 39
3 4 8 BARE OR GREEN 9
1
1
GREEN
2
BLACK
WHITE

BLACK
WHITE

Attach with screws and lock washers provided. Attach with screws. Connect black to black, white to white, and the Replace electrical box cover. Make connection to
green/bare wire under the green screw. breaker box.
NOTE: Housing wiring must be properly installed for
wiring to be correct when wiring unit.

5 WARNING 10 11
To reduce the risk of fire, electric shock, or injury 1
to persons, observe the following:
Use this unit only in the manner intended by the
manufacturer. If you have any questions, contact
the manufacturer.
Before servicing or cleaning unit, switch power off
at service panel and lock service panel to prevent
power from being switched on accidentally. When
the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such
as a tag, to the service panel. 3
2

Remove electrical box cover. Assemble brackets to baffles and insert charcoal filters. Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.

6 7 12 13
1
1

5/16
nut driver

3 3
2 2 2

Flip hood over. Insert 6 of electrical wiring through the CAUTION: Secure vent hood. Make sure mounting Slide spacer front over front lip. Push spacer rear up, Slide filter front over front lip. Push filter rear up, then
top of vent hood and secure. Refer to local codes. screws are secured into framing. Use additional then slide back over rear lip. slide back over rear lip.
mounting screws and wall anchors, if necessary.

40 41
Installation (VWH 18H. Wall & VCWH Chimney Wall Hoods)

1 1-1/2x 3/4
1-
(413/1
.6 6
cm
2 5 6
Slot for
(3.8 cm) x (1.9 cm)
)
1
wood strip 5/16 wood strip 5/16 1
nut driver nut driver

3 3
2 2

Measure down 1-13/16 (4.6 cm) from desired height of Use additional mounting screws to secure hood to Slide spacer front over front lip. Push spacer rear up, Slide filter front over front lip. Push filter rear up, then
hood and secure 1-1/2 x 3/4 wood strip (provided wood strip. then slide back over rear lip. slide back over rear lip.
locally) to wall using screws provided.
Duct Cover Option (VWH 18H. Wall Hoods)
3 5/16
1 2 2
nut driver
5/16
nut driver

CAUTION: Secure vent hood to wall using screws CAUTION: If not using a duct cover, using screws
provided. Use additional mounting screws and wall provided, make sure top mounting screws are secured Measure distance from ceiling to canopy. Slide the duct cover in place and fasten from inside
anchors, if necessary. into soffit or cabinet framing use additional mounting canopy using the sheet metal screws provided.
screws, if necessary.

4
1

To install ventillation kit


refer to ventillation kit
installation instructions.

3
2

Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.

42 43
Duct Cover Option (VCWH Chimney Wall Hoods) Installation (VIH/VCIH Island Hoods)
1 2 1 2

Measure distance from ceiling to canopy. Tape to avoid scratching. Check framing where cutout will be. Cut appropriate size hole in ceiling. Either 7 or 10
NOTE: 200 lb. limit. depending on your specific unit and ventillator kit.

3 4 A1
Mounting options:
Using duct cover with ceiling mounting
bracket. (Option A - VCIH only)

Using threaded rod for additional support.


(Option B)
Attaching hood directly to soffit or
2 duct cover.
(Skip to step 3)

Place duct cover top inside duct cover base and lower until Slide the duct cover in place and fasten from inside Attach duct cover to optional ceiling mounting bracket.
desired height is found. Mark height. Use the retaining canopy using the sheet metal screws provided.
nuts and bolts to fasten in place and remove tape.

A2 B1
5/16
nut
driver

Attach duct cover to ceiling. The ceiling bracket can be Additional support option. Drill holes in all four corners
hidden by using a locally supplied trim. for threaded rod and run rods from hood to ceiling.

44 45
3 4
5/16
Service & Registration
nut
driver

Service & Parts


Only authorized replacement parts may be
used in performing service on the appliance.
Do not repair or replace any part of the
appliance unless specifically recommended in
the manual. All other servicing should be
referred to a qualified technician.
Run duct work down to bottom edge of duct Attach canopy to duct cover/soffit. Seal top of hood to
cover/soffit and secure in place. Make sure the duct duct with aluminum tape. Record the following information indicated
does not stick down past the cover. below. You will need it if service is ever required.
The serial number and model number for your
appliance are located on the identification plate
5 mounted on the inside of the hood canopy.
1
Model number
To install ventillation kit
refer to ventillation kit _________________________________________
installation instructions.
Serial number

_________________________________________
2
3
Date of purchase
Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.
_________________________________________

Date installed
6 7
_________________________________________
1
1
Dealer's name

_________________________________________

Address
3
3

_________________________________________
2 2

Slide spacer front over front lip. Push spacer rear up, Slide filter front over front lip. Push filter rear up, then
then slide back over rear lip. NOTE: Number of spacers slide back over rear lip.
and baffles may vary by model.

46 47