Professional Documents
Culture Documents
Table of contents:
Command Input/Output
Input IFC-P/IFC-D
See IFC-D
Digital Interface
64 Kb/s X21 or
G703.1
2 Mb/s G703.6 sym. 120 Ohm
G703.6 asym. 75 Ohm
Transmission time *
*Values are given for the IFC-P module. If the IFC-D module is used all specified signal transmission delays are prolonged
by about 4 ms
Security
Dependability
Modulation type
Broadband equipments
Narrowband modulation
* Values are given for the IFC-P module. If the IFC-D module is used all specified signal transmission delays are pro-
longed by about 4 ms
Operation via the PLC system ESB 2000i will prolong the transmission time by about 4ms
*Values are given for the IFC-P module. If the IFC-D module is used all specified signal transmission delays are prolonged
by about 4 ms
Operation via the PLC system ESB 2000i will prolong the transmission time by about 4ms
Power Supply
Input voltage 20 72 V DC / 22 60 V AC
Power Consumption max. 3,5 W
Alarm Output
Contact type Changeover contact
Switching power max. 1250 VA / 150 W
Switching voltage max. 380 V AC / 220 V DC
Continuous current 5 A AC/DC
Mechanical Design
Dimensions (approx) 230x110x60 mm
(mounting onto DIN rail)
Insulation withstand voltage
Power supply 2,5 kVrms
Alarm outputs 2,5 kVrms
Digital input/output
G703.6 sym. 500 Vrms
Security
Dependability
Transmitter
Impedance 600 Ohm
Level (max.) +15 dBm
Receiver
Impedance 600 Ohm or 6 kOhm
Level range -40 dB to + 4 dB
Power supply
Input voltage
Power consumption
approx. 22 W / VA
*) Regardless of the adjusted input voltage the max. voltage of 287,5 V DC can be connected
Clock-Synchronization Input
Network management
SNMPv2 on Ethernet Interface 10/100 BaseT
Service PC
Immunity
Bursts
Power supply 4 kV
Data lines 4 kV
Surges
Common mode (line-to-line) 4 kV
Differential mode (line-to-ground) 2 kV
Direct coupling into shield
(communication cable) 2 kV
Conducted disturbances 10 Veff (150 kHz 80 MHz)
Emission
Mechanical design
Dimensions
ES 902 C (19 inch)
482.6 240
37.4
132
132
57.15
84TE=426.72
465.1
Weight
approx. 5 kg (one SWT 3000 in ES 902 C frame)
VF input / output 1 kV
Power supply 5 kV
Alarm outputs 5 kV
Climatic Conditions
Mechanical Conditions
Degree of protection IP 20
9 200 Hz:
0,5 g acceleration
Shock 10 g acceleration
International Standards
Performance and testing of teleprotection transmis- IEC 60834-1 second edition 1999-10
sion equipments of power systems
Power supply and electromagnetic compatibility IEC 60870-2-1