Professional Documents
Culture Documents
CommonFeatures:
Refrigerant:R134agas
WorkingTemperature(ambient):30 ~+43
Multimodesofoperation:Economy/Hybrid/Eheatermode
Disinfection:AutomaticweeklyantiLegionellafunction
Condensercoilwrappedaroundoutsideoftank.
COP3.23.6(15/12 ,15to45 )
Refrigerantcoilwrappedoutsidethestainlesssteelinsulatedhotwaterstoragetankforaddedprotectionand
nocrosscontamination.
Ductable:30Paairinletandoutletstaticpressureenableductedlengthupto10meters.4wayvalvebuiltin
forautomaticdefrosting.Optionalremotecontrol.
Fan Assy
Compressor
Evaporator
Display
Magnesian Stick
Electric Heater(Upper)
Cover,Electric heater(Lower)
Water Inlet
Drainpipe
Electric Heater(Lower)
Safety
a. Completeisolationbetweenwaterandelectricity.No
electricshockproblem,moresafety.
b. Nofueltubesandstorage,nopotentialdangerfromoil
leakage,fire,explosionetc.
c. Nocrosscontaminationpotential,thecondensercoil
wrappedaroundtheporcelainenamelinnertank
Remark:
1. Thetestconditions:outdoortemp.20/15(DB/WB),inletwatertemp.15,outletwatertemp.60.
2.Theoperationrange:2043,heatpumpoperationrange:743
3. Thespecificationmaybechangedforproductimprovement,pleaserefertothenameplate.
1. Dimensions
Model A B C D
RSJ15/150RDN3 568 560 1100 1300
RSJ15/190RDN3 568 560 1376 1576
RSJ30/300RDN3 638 630 1500 1800
2. Service Space
200mm
600mm
Display
3. Wiring Diagrams
220V AC
L G N 50 Hz
T3
T4 H-A
T5U G-A
T5L Main Control Board
TP G-B
Compressor
Control Panel
Earthing
4. Piping Diagrams
5. Exploded View