Professional Documents
Culture Documents
The Alcatel-Lucent 7210 SAS family of compact, Ethernet-edge, demarcation and aggregation
devices enables cost-effective Carrier Ethernet services delivery to the customer edge and
extends the reach of MPLS-enabled Carrier Ethernet aggregation networks into smaller central
offices and distributed hub sites.
TECHNICAL SPECIFICATIONS
Table 1. Alcatel-Lucent 7210 SAS platform variants
7210 SAS-D 7210 SAS-E 7210 SAS-M 7210 SAS-M (10GigE) 7210 SAS-X
Interfaces 6 x 100/1000BASE 12 x 24 x 100/1000BASE 24 x 100/1000BASE 24 x 100/1000BASE
(SFP) + 4 x 10/100/ 10/100/1000BASE-TX (SFP) + 1 expansion (SFP) + 2 x 10GBASE (SFP) + 2 x 10GBASE
1000BASE-TX + 12 x 100/1000BASE slot + support for (XFP) + 1 expansion (XFP) + support for
+ support for (SFP) + support for 10/100/1000BASE-TX slot + support for 10/100/1000BASE-TX
10/100/1000BASE-TX 10/100/1000BASE-TX copper SFPs, DWDM 10/100/1000BASE-TX copper SFPs, DWDM
copper SFPs, DWDM and copper SFPs, DWDM and and CWDM SFPs and copper SFPs, DWDM and CWDM SFPs and
CWDM SFPs and SFPs CWDM SFPs and SFPs SFPs/XFPs with digital and CWDM SFPs and SFPs/XFPs with digital
with digital diagnostic with digital diagnostic diagnostic monitoring SFPs/XFPs with digital diagnostic monitoring
monitoring (DDM) monitoring (DDM) (DDM) capabilities diagnostic monitoring (DDM) capabilities
capabilities capabilities (DDM) capabilities
System throughput Wirespeed 20 Gb/s Wirespeed 48 Gb/s Wirespeed 88 Gb/s Wirespeed 128 Gb/s Wirespeed 88 Gb/s
(half duplex) (half duplex) (half duplex) (half duplex) (half duplex)
Ethernet (including QinQ, Yes Yes Yes (with multi-chassis Yes (with multi-chassis Yes (with multi-chassis
xSTP and ITU-T G.8032v2, LAG) LAG) LAG)
IEEE 802.3.ad)
7210 SAS-D 7210 SAS-E 7210 SAS-M 7210 SAS-M (10GigE) 7210 SAS-X
OAM ITU-T Y.1731 with ITU-T Y.1731 with ITU-T Y.1731 with ITU-T Y.1731 with ITU-T Y.1731 with
Synthetic Loss Synthetic Loss Synthetic Loss Synthetic Loss Synthetic Loss
Measurement (SLM) Measurement (SLM) Measurement (SLM) Measurement (SLM) Measurement (SLM)
IEEE 802.1ag IEEE 802.1ag IEEE 802.1ag IEEE 802.1ag IEEE 802.1ag
IEEE 802.3ah IEEE 802.3ah IEEE 802.3ah IEEE 802.3ah IEEE 802.3ah
Out-of-band man Out-of-band man Out-of-band man Out-of-band man
agement over IPv6 agement over IPv6 agement over IPv6 agement over IPv6
Timing and ETR system: ITU-T N/A ITU-T Sync-E with ITU-T Sync-E with ITU-T Sync-E with
synchronization Sync-E with stratum-3 stratum-3 (TXCO) stratum-3 (TXCO) stratum-3E (OXCO)
(TXCO) system clock system clock system clock system clock
Temperature operating Standard system: Standard system: Standard system: Standard system: Standard system:
range 0C to 40C 0C to 50C 0C to 50C 0C to 50C 0C to 50C
(32F to 104F) (32F to 122F) (32F to 122F) (32F to 122F) (32F to 122F)
ETR system: ETR system:
-40C to +65C -40C to +65C
(-40F to +149F) (-40F to +149F)
using the 7210 SAS-D using the 7210 SAS-M
(ETR) (10GigE ETR)
Hot-swappable modules N/A Power supplies, fan tray Service expansion Service expansion Power supplies, fan tray
modules, power modules, power
supplies, fan tray supplies, fan tray
Power supply The 7210 SAS-D has Integrated redundant Integrated redundant Integrated redundant Integrated redundant
redundancy a single integrated power supplies power supplies power supplies power supplies
power supply. The
7210 SAS-D (ETR) has a
single integrated power
supply and supports
redundancy using an
external power supply.
Power requirements AC input: 100 V AC input: 100 V AC input: 100 V to AC input: 100 V to AC input: 100 V
to 240 V, 50 Hz to 240 V, 50 Hz 240 V, 50 Hz to 240 V, 50 Hz to to 240 V, 50 Hz
to 60 Hz; output: to 60 Hz; output: 60 Hz; output: 60 Hz; output: to 60 Hz; output:
+12 V DC +12 V DC +12 V DC +12 V DC [ETR +12 V DC
non-redundant DC input: -36 V DC DC input: -36 V DC and non-ETR rated DC input: -36 VDC
DC input: -36 V DC to -72 V DC; output: to -72 V DC; output: variants available] to -72 V DC; output:
to -72 V DC; +12 V DC +12 V DC DC input: -36 V DC +12 V DC
output: +12 V DC Supports concurrent DC input: +24 V DC; to -72 V DC; output: Supports concurrent
non-redundant use of AC and DC DC output: +12 V DC [ETR use of AC and DC
DC input: +24 V DC; power supplies +12 V DC and non-ETR rated power supplies
output: +12 V DC variants available]
Supports concurrent
non-redundant use of AC and DC DC input: +24 V DC;
[ETR variant only] power supplies output: +12 V DC
[ETR rated]
Supports concurrent
use of AC and DC
power supplies
Dimensions Height: 4.28 cm Height: 6.7 cm Height: 6.7 cm Height: 6.7 cm Height: 8.8 cm
(1.69 in.) (2.64 in.) (2.64 in.) (2.64 in.) (3.47 in.)
Width: 26.5 cm Width: 43.6 cm Width: 43.6 cm Width: 43.6 cm Width: 43.9 cm
(10.43 in.) (17.17 in.) (17.17 in.) (17.17 in.) (17.3 in.)
Depth: 17.5 cm Depth: 25.3 cm Depth: 25.3 cm Depth: 25.3 cm Depth: 27.9 cm
(6.89 in.) (9.96 in.) (9.96 in.) (9.96 in.) (11 in.)
Railway
EN 50121-4
IEC 62236-4
www.alcatel-lucent.com Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of
Alcatel-Lucent. All other trademarks are the property of their respective owners. The information presented
is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein.
Copyright 2012 Alcatel-Lucent. All rights reserved. M2012053062 (May)