You are on page 1of 1

300

125
492
Rain
water
pipe
DUCT OUTPUT DUCT OUTPUT Chajja
2450 1.23x0.679 3070 1.23x0.679 2130
Plaster finish in C.M 1:5 with sponge finish. Chajja
painted with water proof Exterior distemper Plaster finish in C.M 1:5 with sponge finish.
painted with water proof Exterior distemper
Chajja W- 1.2x1.35 W- 1.2x1.35 3300
2500
2129 2100
500 7460 600

Stone / c.c block masonry all round


Plinth protection 75 mm thick 600 with c.m. 1:4 and plaster on block work 1250
mm wide with C.C. 1:2:4 in c.m. 1:4 till 300 mm below the NGL

GL GL

SIDE VIEW

10560

w1 w1
450

D1

w1

STAIR
DC INVERTER AC DC INVERTER AC Normal Shutter up to 0.75 m
Termination Termination
Panel
Termination Termination
Panel and above with mesh and filter
Panel
3.8x1.0 Panel
3.8x1.0
Plaster finish in C.M 1:5 with sponge finish.
Plaster finish in C.M 1:5 with sponge finish. 1500 painted with water proof Exterior distemper
painted with water proof Exterior distemper
Chajja Chajja Chajja Chajja

ROLLING SHUTTER
Duct Duct Facing vertically downward to
Duct Duct
avoid water entry during storm
Facing vertically downward to

RAMP
w1
avoid water entry during storm
5360 2000 2000 ROLLING SHUTTER

Alu.Entry Door
W- 1.2x1.35 W- 1.2x1.35 W- 1.2x1.35 W- 0.9x1.35 2.0x2.5

0.6x2.1
2100 2129
540 340 340 540 500 500 390 390
1800 780
750 300
INVERTER INVERTER
w1

AC DC AC DC

w2
Termination Termination Termination Termination
Panel
3.8x1.0 Panel Panel
3.8x1.0 Panel

Stone / c.c block masonry all round


Plinth protection 75 mm thick 600 with c.m. 1:4 and plaster on block work RAMP STEPS
Plinth protection 75 mm thick 600
mm wide with C.C. 1:2:4 in c.m. 1:4 till 300 mm below the NGL
mm wide with C.C. 1:2:4
GL GL GL GL
w1
REAR VIEW
FRONT VIEW

INVERTOR ROOM PLAN

300
125
492
Rain
water 900
DUCT OUTPUT DUCT OUTPUT pipe Chajja
1580 1.23x0.679 3070 1.23x0.679 3450
600
Chajja
Plaster finish in C.M 1:5 with sponge finish. Chajja
painted with water proof Exterior distemper Plaster finish in C.M 1:5 with sponge finish.
painted with water proof Exterior distemper W- 1.2x1.35 3300
2500
2129 2100
8960 600
750

Stone / c.c block masonry all round


Plinth protection 75 mm thick 600 with c.m. 1:4 and plaster on block work 1250
mm wide with C.C. 1:2:4 in c.m. 1:4 till 300 mm below the NGL NOTES:-
GL GL 1. ALL THE DIMENSIONS ARE IN MM, ONLY WRITTEN DIMENSIONS TO BE
FOLLOWED,
2. THIS DRAWING IS TO BE READ IN REFERENCE TO CENTERLINE DRAWING.
SIDE VIEW IF ANY DISCREPANCY FOUND, BRING TO THE NOTICE OF ENGINEER INCHARGE.
3. ALL EXTERNAL WALL WILL BE 230 MM THICK WITH BRICK MASONRY.
4. STRUCTURAL DRAWINGS TO BE FOLLOWED FOR SLAB, BEAMS, LINTELS
CHAJJA AND OTHER STRUCTURAL ELEVENTHS.
5. PLINTH HEIGHT SHELL BE AT 1200 MM MIN. FROM NATURAL GROUND LEVEL
OR AS DIRECTED BY
ENGINEER INCHARGE, TO AVOID ENTRY OF WATER IN TO CABLE TRENCHES
6. FOR CABLE TRENCH AND CABLE ENTRY DETAILS, PLEASE REFER SEPARATE
DRAWINGS.
7. DUCTING DETAILS AND WALL OPENINGS SHOULD BE READ IN CONNECTION
WITH INVERTER GA DETAILS.

DESCRIPTION:- INSTALLATION OF 10 MW SOLAR PV TITLE:- INVERTER ROOM ELEVATION DETAIL SIZE:- A1 SCALE:-NTS
POWER PLANT AT MAHARASHTRA PROJECT DRG. NO.:- RPIPL-KWFDPL-IR-ED-002 REV.:-0 SH. 1 OF 1