GasTurb 13 Tutorial 4

OPTMZNG A CYCLE
Copyright GasTurb GmbH
GasTurb 12 Main Window

For this tutorial we will use a


Turbojet.
Copyright GasTurb GmbH
We Need Some Data

Select the
engine model

Open the engine


model
Copyright GasTurb GmbH
Input Data Page
Copyright GasTurb GmbH

First we run a
single cycle
Starting Point of the Optimization
Copyright GasTurb GmbH
Optimization Task:
Find the Compressor Pressure Ratio for Minimum SFC

A parametric study
with Pressure Ratio as
the only parameter
yields

The SFC minimum is at


Copyright GasTurb GmbH

pressure ratio 65

The optimization
feature allows finding
the SFC minimum
without doing a
parametric study.
Selecting Optimization
Copyright GasTurb GmbH

Now we go for
Optimize.
Optimization Input Window

The Min Value must be lower The Max Value must be


than the Start Value higher than the Start Value

First drag the Optimization Variable


to the input grid.

Next enter boundaries for the


Copyright GasTurb GmbH

variables.

Finally define the Figure of Merit


Optimization Input Window
The Figure of Merit can be
maximized or minimized. Of
course SFC shall be minimized

Drag your Figure of Merit to the box.

Now run the optimization


Copyright GasTurb GmbH
The Optimization Window

The upper boundary


(Max Value)
for the variable
The lower boundary
(Min Value)
for the variable

Click to run the optimization


Copyright GasTurb GmbH

Let us have a look at the result.


SFC Optimum
Copyright GasTurb GmbH

This result is somewhat unrealistic


for a turbojet - among other reasons
because the turbine pressure ratio is
almost 24.
Repeating the Optimization
Copyright GasTurb GmbH
Repeating the Optimization
Copyright GasTurb GmbH
Introducing Constraints

The Min Value must be lower


than the Start Value The Max Value must be
higher than the Start Value

We introduce as Constraint the


Turbine Pressure Ratio.
Copyright GasTurb GmbH

We enter for the upper boundary


(Max Value) 4. This is a reasonable
limit for a single stage turbine.
The Min Value is of no relevance for this
optimization problem.

Then we re-run the optimization.


End of the Constrained Optimization

The value of the optimization The value of the optimization


variable is within the Min and constraint is equal to the Max
Max Values Value
Copyright GasTurb GmbH
Result of the Constrained Optimization

This introduction to optimization


was very simple. The problem
could have been solved also with
a simple parametric study.
Turbine Pressure Ratio is 4
Next we go for a more complex
Copyright GasTurb GmbH

task which would require many


parametric studies for finding the
optimal solution.

Applying numerical optimization


leads quickly to the result.
GasTurb 12 Main Window

We will consider a Geared Unmixed


Flow Turbofan.
Copyright GasTurb GmbH

The file opening menu will appear


automatically,
read the file
Demo_gtf.CYG

After reading the data, the design


input window opens.
Input Data Page
Copyright GasTurb GmbH

First we run a
single cycle
Starting Point of the Optimization
Copyright GasTurb GmbH

After closing this window click


Optimization.
Then, hit the Optimize button.
Optimization Input
The Figure of Merit is
again SFC

There
are five
and three
optimization
Constraints.
variables
Copyright GasTurb GmbH
Optimization Status

Status
Status at at
thethe end of of
begining thethe
optimization

Let us have a look


at the optimum
Copyright GasTurb GmbH
Result of the Optimization

The SFC was previously 16.51,


Optimization has reduced it by 6.3%.

Net Thrust >= 31 kN

T45 <=1300K
Copyright GasTurb GmbH

LPT Pressure Ratio <=12


The solution fulfills
the Constraints
Optimization Input

Do all of these
constraints really
apply to Cruise
conditions?

No !
the LPT Inlet Temperature T45 Limit must not be
exceeded during a hot day Take-Off.
Copyright GasTurb GmbH

Next we will show how this can be taken into


account.
We have optimized the
cycle for minimum SFC Go back to the GasTurb Main Window.
at cruise conditions. When asked to restore the old data, chose
However, Yes.
GasTurb 12 Main Window

Select Off Design

and Standard Maps


Copyright GasTurb GmbH
Select the Mission Option
Copyright GasTurb GmbH
Mission Input

Run the Single Point Mission


and check if the off-design
iteration converges.
Choose a Single Point Mission
Close the Mission Windows and
and enter the Take-Off operating
go back to the GasTurb12 Main
conditions as well as the required
Window. Switch back to the
thrust of 145kN
Calculation Mode Design and
select Performance.

In the Design Input Window click


Optimization and Run.
Copyright GasTurb GmbH
Design and Off-Design Constraints
Click Select Case 1 to apply
Constraints the T45 constraint to the
off-design condition.

These dropdown lists are


visible only if a mission is
defined.
Copyright GasTurb GmbH
After the Optimization Run
Copyright GasTurb GmbH
The Cycle Design Point

The SFC was previously 16,51.


Single Point Optimization yielded 15,47.
but T45 at Hot Day Take-Off was 1351K.

With additional constraint for Off Design Net Thrust >= 31 kN


(T45 <= 1300K), SFC is reduced by 5.3%.

T45 is not
constrained at
the cycle design
point
Copyright GasTurb GmbH

LPT Pressure Ratio <=12


Hot Day Sea Level Take-Off

T45 <=1300K
Copyright GasTurb GmbH

This slide ends the


Control System
Optimization Tutorial